If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
(Created page with "== Well Details == {{115-20676-Details}} __TOC__ == Well Inspection Data == {{115-20676-inspection}} == Production Data == {{115-20676-production}} == Waste Data == {{115-2067...") |
|||
Line 1: | Line 1: | ||
== Well Details == | == Well Details == | ||
− | { | + | {| class="wikitable" width="95%" |
+ | | Well ID: 115-20676 | ||
+ | | style="width: 50%; height=100%; align=center" rowspan="14" | {{#display_map: 41.814722, -75.766052 | width=100% | height=100% }} | ||
+ | |- | ||
+ | | County: [[Susquehanna County, Pennsylvania|Susquehanna]] | ||
+ | |- | ||
+ | | Municipality: [[New Milford Township, Susquehanna County, Pennsylvania|New Milford Township]] | ||
+ | |- | ||
+ | | Operator Name: [[SOUTHWESTERN ENERGY PROD CO]] | ||
+ | |- | ||
+ | | Farm/Lease Name: ZEFFER 3H | ||
+ | |- | ||
+ | | First Permit Date: 2011-10-04 | ||
+ | |- | ||
+ | | Last Permit Date: 2011-10-04 | ||
+ | |- | ||
+ | | Spud Date: 2011-10-25 | ||
+ | |- | ||
+ | | Unconventional: Yes | ||
+ | |- | ||
+ | | Horizontal: Yes | ||
+ | |- | ||
+ | | Producing: Yes | ||
+ | |- | ||
+ | | Violations: None | ||
+ | |- | ||
+ | | Latitude: 41.814722 | ||
+ | |- | ||
+ | | Longitude: -75.766052 | ||
+ | |- | ||
+ | |} | ||
__TOC__ | __TOC__ | ||
== Well Inspection Data == | == Well Inspection Data == | ||
− | { | + | {| class="wikitable sortable" width="95%" |
+ | !scope="col" | INSPECTION ID | ||
+ | !scope="col" | DATE | ||
+ | !scope="col" | DESCRIPTION | ||
+ | !scope="col" | COMMENT | ||
+ | !scope="col" | VIOLATION ID | ||
+ | |- | ||
+ | | 2031176 | ||
+ | | 2012-01-03 | ||
+ | | No Violations Noted | ||
+ | | DDI-10...Co. man - Joe Davis. Circulating at time of inspection. Depth of drilling = 7665'. Walked site with Co. Man. Secondary containment in place. Drillers log on site and up to date. Cement reports show adequate cement quantities. | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2074435 | ||
+ | | 2012-05-31 | ||
+ | | No Violations Noted | ||
+ | | Well drilled. operator reported bubbling outside of casing. At time of inspection I observed minor bubbling between 9 5/8" and 13 3/8" casings. No other bubbling observed. No activity on site. Secondary containment still down around well. Will Follow up with Operator on condition of well. No violations observed at this time. Well tag and site i.d. sign in place. | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2110216 | ||
+ | | 2012-10-15 | ||
+ | | Pending | ||
+ | | DDI-10 on site drilling Zeffer 2H. During inspection checked cellar - observed bubbling in cellar of 3H. Consistent bubbling outside 9 5/8" approximately 1/4" in size. Cellar half full of water so could not see source of bubbling. Requested Operator to pump down cellar and identify source and report to DEP. Copy of detailed Summary Sheet provided for this well by Co. Man. at time of inspection. Violation is Pending. | ||
+ | | | ||
+ | |- | ||
+ | |} | ||
== Production Data == | == Production Data == | ||
− | { | + | {| class="wikitable sortable" width="95%" |
+ | !scope="col" | PERIOD | ||
+ | !scope="col" | GAS QUANTITY | ||
+ | !scope="col" | GAS PRODUCTION DAYS | ||
+ | !scope="col" | CONDENSATE QUANTITY | ||
+ | !scope="col" | CONDENSATE PRODUCTION DAYS | ||
+ | !scope="col" | OIL QUANTITY | ||
+ | !scope="col" | OIL PRODUCTION DAYS | ||
+ | |- | ||
+ | | 2012-2 | ||
+ | | style="text-align:right;" | 148948.0 | ||
+ | | style="text-align:right;" | 34.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | |- | ||
+ | |- | ||
+ | | 2012-1 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | |- | ||
+ | |- | ||
+ | | 2011-2 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | |- | ||
+ | |} | ||
== Waste Data == | == Waste Data == | ||
− | { | + | {| class="wikitable sortable" width="95%" |
+ | !scope="col" | PERIOD | ||
+ | !scope="col" | TYPE | ||
+ | !scope="col" | QUANTITY | ||
+ | !scope="col" | UNITS | ||
+ | !scope="col" | DISPOSAL METHOD | ||
+ | !scope="col" | WASTE FACILITY PERMIT ID | ||
+ | !scope="col" | WASTE FACILITY NAME | ||
+ | !scope="col" | FACILITY CITY | ||
+ | !scope="col" | FACILITY STATE | ||
+ | |- | ||
+ | | 2012-2 | ||
+ | | FLOWBACK FRACTURING SAND | ||
+ | | style="text-align:right;" | 466.36 | ||
+ | | Tons | ||
+ | | LANDFILL | ||
+ | | 101247 | ||
+ | | KEYSTONE SANITARY LANDFILL | ||
+ | | DUNMORE | ||
+ | | PA | ||
+ | |- | ||
+ | |- | ||
+ | | 2012-1 | ||
+ | | DRILL CUTTINGS | ||
+ | | style="text-align:right;" | 360.03 | ||
+ | | Tons | ||
+ | | LANDFILL | ||
+ | | THR029 | ||
+ | | TUNNELL HILL RECLAMATION LANDFILL | ||
+ | | NEWLEXINGTON | ||
+ | | OH | ||
+ | |- | ||
+ | |} | ||
__NOEDITSECTION__ | __NOEDITSECTION__ |
Well ID: 115-20676 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.814722,"lon":-75.766052,"icon":""}]} |
County: Susquehanna | |
Municipality: New Milford Township | |
Operator Name: SOUTHWESTERN ENERGY PROD CO | |
Farm/Lease Name: ZEFFER 3H | |
First Permit Date: 2011-10-04 | |
Last Permit Date: 2011-10-04 | |
Spud Date: 2011-10-25 | |
Unconventional: Yes | |
Horizontal: Yes | |
Producing: Yes | |
Violations: None | |
Latitude: 41.814722 | |
Longitude: -75.766052 |
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID |
---|---|---|---|---|
2031176 | 2012-01-03 | No Violations Noted | DDI-10...Co. man - Joe Davis. Circulating at time of inspection. Depth of drilling = 7665'. Walked site with Co. Man. Secondary containment in place. Drillers log on site and up to date. Cement reports show adequate cement quantities. | |
2074435 | 2012-05-31 | No Violations Noted | Well drilled. operator reported bubbling outside of casing. At time of inspection I observed minor bubbling between 9 5/8" and 13 3/8" casings. No other bubbling observed. No activity on site. Secondary containment still down around well. Will Follow up with Operator on condition of well. No violations observed at this time. Well tag and site i.d. sign in place. | |
2110216 | 2012-10-15 | Pending | DDI-10 on site drilling Zeffer 2H. During inspection checked cellar - observed bubbling in cellar of 3H. Consistent bubbling outside 9 5/8" approximately 1/4" in size. Cellar half full of water so could not see source of bubbling. Requested Operator to pump down cellar and identify source and report to DEP. Copy of detailed Summary Sheet provided for this well by Co. Man. at time of inspection. Violation is Pending. |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
2012-2 | 148948.0 | 34.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2012-1 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|---|---|---|---|---|---|---|---|
2012-2 | FLOWBACK FRACTURING SAND | 466.36 | Tons | LANDFILL | 101247 | KEYSTONE SANITARY LANDFILL | DUNMORE | PA |
2012-1 | DRILL CUTTINGS | 360.03 | Tons | LANDFILL | THR029 | TUNNELL HILL RECLAMATION LANDFILL | NEWLEXINGTON | OH |