| style="width: 50%; height=100%; align=center" rowspan="14" | {{#display_map: 41.639313, -75.973297 | width=100% | height=100% }}  
 
| style="width: 50%; height=100%; align=center" rowspan="14" | {{#display_map: 41.639313, -75.973297 | width=100% | height=100% }}  
 
|-
 
|-
| County: [[Wyoming County, Pennsylvania|Wyoming]]
+
| County: [[wikipedia:Wyoming County, Pennsylvania|Wyoming]]
 
|-
 
|-
| Municipality: [[Washington Township, Wyoming County, Pennsylvania|Washington Township]]
+
| Municipality: [[wikipedia:Washington Township, Wyoming County, Pennsylvania|Washington Township]]
 
|-
 
|-
| Operator Name: [[CHESAPEAKE APPALACHIA LLC]]
+
| Operator Name: [[wikipedia:CHESAPEAKE APPALACHIA LLC|CHESAPEAKE APPALACHIA LLC]]
 
|-
 
|-
 
| Farm/Lease Name: MCGRAW 2H
 
| Farm/Lease Name: MCGRAW 2H

Revision as of 22:22, 2 May 2014

Well Details

Well ID: 131-20037
Loading map...
County: Wyoming
Municipality: Washington Township
Operator Name: CHESAPEAKE APPALACHIA LLC
Farm/Lease Name: MCGRAW 2H
First Permit Date: 2010-05-12
Last Permit Date: 2010-05-12
Spud Date: 2010-08-24
Unconventional: Yes
Horizontal: Yes
Producing: Yes
Violations: 6
Latitude: 41.639313
Longitude: -75.973297

Well Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID
1922616 2010-10-25 No Violations Noted Rigging down to move to McGraw 5H
1930322 2010-11-23 Violation(s) Noted Onsite visit with DEP Geologist (Eric Rooney) and DEP WQS (Ryan Klemish). Followup inpsection of possible stray gas in cellar. Lower elbow on the 2" vent line of the 13 3/8" annulus had bubbles migrating out of joint. Small intermitent bubbles seen every 10 sec. Approx 6" of water in cellar at time of inspection. Asked DEP rep to use flir camera to detect any gas that may be present as I wasn't sure if bubbling from elbow was gas migration or plumbing problem. Also, Gauge on 13 3/8 showing 0 psi, however vavle closed during time of inspection and possible loose elbow. Talked with completions supervisor Nick Pottmeyer stating they would go out and tighten up fittings, open the vavle and monitor for any pressure buildup. Also asked Mr. Pottmeyer to replace the guage on the string with one with smaller graduations to detect any gas that may be present. 601700
1930322 2010-11-23 Violation(s) Noted Onsite visit with DEP Geologist (Eric Rooney) and DEP WQS (Ryan Klemish). Followup inpsection of possible stray gas in cellar. Lower elbow on the 2" vent line of the 13 3/8" annulus had bubbles migrating out of joint. Small intermitent bubbles seen every 10 sec. Approx 6" of water in cellar at time of inspection. Asked DEP rep to use flir camera to detect any gas that may be present as I wasn't sure if bubbling from elbow was gas migration or plumbing problem. Also, Gauge on 13 3/8 showing 0 psi, however vavle closed during time of inspection and possible loose elbow. Talked with completions supervisor Nick Pottmeyer stating they would go out and tighten up fittings, open the vavle and monitor for any pressure buildup. Also asked Mr. Pottmeyer to replace the guage on the string with one with smaller graduations to detect any gas that may be present. 601701
1931929 2010-11-30 Violation(s) Noted Follow-up of loose elbow on 2" vent line of 13 3/8". Water drained from cellar. Gauges were replaced with those of smaller graduations on casing strings. 300PSI on production string. 600760
1931929 2010-11-30 Violation(s) Noted Follow-up of loose elbow on 2" vent line of 13 3/8". Water drained from cellar. Gauges were replaced with those of smaller graduations on casing strings. 300PSI on production string. 600761
1931939 2010-12-03 Violation(s) Noted All valves were open and that there was no pressure on any of the gauges (including the production string). I also noted that there was a brass vented nipple installed on the 2" vent line that appeared to be on the outside of the 13 3/8" annulus. 600762
1931939 2010-12-03 Violation(s) Noted All valves were open and that there was no pressure on any of the gauges (including the production string). I also noted that there was a brass vented nipple installed on the 2" vent line that appeared to be on the outside of the 13 3/8" annulus. 600763
1939058 2010-12-22 No Violations Noted Reading at wellhead measured 50% methane on vent of 13 3/8". During time of inspection noted that pressure guages were removed from the wellhead.
1944427 2011-01-04 No Violations Noted Preparing location for fract ops
1950451 2011-02-16 No Violations Noted
1955249 2011-01-24 No Violations Noted Checked well. Head being heated. No activity. 13 3/8" being vented.
1966044 2011-04-07 No Violations Noted Laying down mats and liner to prepare for spudding of 5H
1985334 2011-06-30 No Violations Noted 200# gauge on surface. 0 psi. Contacted Nick Pottmeyer requesting smaller gauge (50#) on surface casing string.
1987623 2011-07-13 No Violations Noted 13 3/8 gauges replaced wth 50# as requested. All other gauges 100#
2004017 2011-09-19 No Violations Noted
2062439 2012-03-15 No Violations Noted cellar is dug out, no water. 9 5/8" X 13 3/8" annulus vented. Checked with gas meter, no gas.
2120690 2012-09-13 No Violations Noted Well fract. 2 seperators, 2 tanks. 8 Brine water tanks, 11 fresh water tanks on location

13 X 9 - -0.6735 psi. Vented to atmosphere (70% spike combustible gas, 68% hold utilizing MSA 60) 9 X 5 - -2.4680 psi (not vented) 5 1/2 - 29.634 psi

2133552 2013-01-15 No Violations Noted Producing well. No water in cellar.

tbg = 2749.9 psi 5 1/2" csg = 11.1 psi 5 1/2 x 9 5/8" annulus = 0.94 psi 9 5/8 x 13 3/8" annulus = 2.28 psi Also on pad, 5H is producing and 1 empty cellar.

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2012-2 827205.0 93.0 0.0 0.0 0.0 0.0
2012-1 0.0 0.0 0.0 0.0 0.0 0.0
2011-2 0.0 0.0 0.0 0.0 0.0 0.0
2011-1 0.0 0.0 0.0 0.0 0.0 0.0
2010-2 0.0 0.0 0.0 0.0 0.0 0.0
2010-3 0.0 0.0 0.0 0.0 0.0 0.0

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2012-2 PRODUCED FLUID 55.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119 EUREKA RESOURCES (WILLIAMSPORT WATER TREATMENT) WILLIAMSPORT PA
2012-2 PRODUCED FLUID 726.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR HYDRAULIC FRACTURING
2012-1 PRODUCED FLUID 314.5 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR HYDRAULIC FRACTURING