X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-005-30163"

m
m
Line 1: Line 1:
 
__TOC__
 
__TOC__
 
== Well Details ==
 
== Well Details ==
{| class="wikitable" width="95%"
+
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-005-30163
 
| Well ID: 37-005-30163
| style="width: 50%; height=100%; align=center" rowspan="14" | {{#display_map: 40.642484, -79.54913 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="14" | {{#display_map: 40.642484, -79.54913 | width=100% | height=100% }}  
 
|-
 
|-
 
| Operator Name: [[WOOD WILLIAM C]]
 
| Operator Name: [[WOOD WILLIAM C]]

Revision as of 15:44, 26 June 2014

Well Details

Well ID: 37-005-30163
Loading map...
Operator Name: WOOD WILLIAM C
First Permit Date: 2008-12-31
Last Permit Date: 2008-12-31
Spud Date: 2009-08-31
Unconventional: No
Horizontal: No
Violations: 1
Latitude: 40.642484
Longitude: -79.54913

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2013-0 6053.0 365.0 0.0 0.0 0.0 0.0
2012-0 6526.0 365.0 0.0 0.0 0.0 0.0
2011-0 6581.0 365.0 0.0 0.0 0.0 0.0
2010-0 8314.0 365.0 0.0 0.0 0.0 0.0
2009-0 4084.0 300.0 0.0 0.0 0.0 0.0
2008-0 2842.0 365.0 0.0 0.0 0.0 0.0

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID
1827120 2009-09-10 Violation(s) Noted Drilling appeared to have been completed at the time of the inspection. Below grade pit located onsite. Pit contained drill cuttings and some drilling fluids. Pit had more than the two feet of required freeboard. Observed no accelerated erosion & sedimentation in relation to the access road or well-site. Noted that the filter fabric fence placed onsite had not been installed properly. The stakes had been pounded into the ground, however the fencing itself was not trenched in and was left on the surface of the ground. Installed in this manner the filter fabric fence will not function as an effective sediment barrier. 571226
1865255 2009-10-02 No Violations Noted
1907427 2010-08-20 No Violations Noted Drilling was completed on 09/05/09. Well appeared to be plumbed for production. Observed no accelerated erosion & sedimentation in relation to the access road or well-site. Site had been restored properly and the vegetative cover met the 70% uniform coverage. The Department recommends that the three tanks located onsite be removed, un less the landowner has given written permission that the tanks remain onsite in accordance with regulation citation that requires the removal of all equipment not essential to the production of the well upon completion of site restoration activites.

References