If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
(Created page with "== Well Details == {{021-21176-Details}} __TOC__ == Well Inspection Data == {{021-21176-inspection}} == Production Data == {{021-21176-production}} == Waste Data == {{021-2117...") |
|||
Line 1: | Line 1: | ||
== Well Details == | == Well Details == | ||
− | { | + | {| class="wikitable" width="95%" |
+ | | Well ID: 021-21176 | ||
+ | | style="width: 50%; height=100%; align=center" rowspan="14" | {{#display_map: 40.281483, -78.690058 | width=100% | height=100% }} | ||
+ | |- | ||
+ | | County: [[Cambria County, Pennsylvania|Cambria]] | ||
+ | |- | ||
+ | | Municipality: [[Adams Township, Cambria County, Pennsylvania|Adams Township]] | ||
+ | |- | ||
+ | | Operator Name: [[CHEVRON APPALACHIA LLC]] | ||
+ | |- | ||
+ | | Farm/Lease Name: PMG RABY UNIT 2H | ||
+ | |- | ||
+ | | First Permit Date: 2011-03-29 | ||
+ | |- | ||
+ | | Last Permit Date: 2011-03-29 | ||
+ | |- | ||
+ | | Spud Date: 2011-05-27 | ||
+ | |- | ||
+ | | Unconventional: Yes | ||
+ | |- | ||
+ | | Horizontal: Yes | ||
+ | |- | ||
+ | | Producing: No | ||
+ | |- | ||
+ | | Violations: None | ||
+ | |- | ||
+ | | Latitude: 40.281483 | ||
+ | |- | ||
+ | | Longitude: -78.690058 | ||
+ | |- | ||
+ | |} | ||
__TOC__ | __TOC__ | ||
== Well Inspection Data == | == Well Inspection Data == | ||
− | { | + | {| class="wikitable sortable" width="95%" |
+ | !scope="col" | INSPECTION ID | ||
+ | !scope="col" | DATE | ||
+ | !scope="col" | DESCRIPTION | ||
+ | !scope="col" | COMMENT | ||
+ | !scope="col" | VIOLATION ID | ||
+ | |- | ||
+ | | 2004426 | ||
+ | | 2011-09-13 | ||
+ | | No Violations Noted | ||
+ | | During this inspection, Chevron Regulatory Compliance Personnel and WQS Marc Maestra present. Well ID sign, ES plan onsite. Well tag present. Site gated and locked. Well drilled not yet in production. Access road and entrance adequately rocked. Soil pile seeded/mulched. Slopes secured with erosion blankets exhibiting growth. BMPs installed according to plan.no accelerated erosion or sedimentation issues noted. Although red staining near soil pile and near toe slope of pad is observed-again this was attributed to decomposition of mulch/ tress used during pad construction. While on site all parties noted that soil near sediment trap appears discolored with a ¿red/black¿ hue and the liquid contents of sediment trap appear dark in nature as well- it is also observed that large quantity of leaves present in trap. Operator plans to investigate/sample discoloration of both the soil and liquid fraction from near sed trap. 10-20-11: Bases on site inspection and review of operator results it does not appear discoloration is due to spill or release. | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2016194 | ||
+ | | 2011-11-01 | ||
+ | | No Violations Noted | ||
+ | | At the time of inspection, no E&S or IW discharge issues at the site. Site sign and E&S plan present. Well marker not present. Spud called on 10/31/11. Called Chevron to request well marker placed prior to drilling activity. | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2020137 | ||
+ | | 2011-11-17 | ||
+ | | No Violations Noted | ||
+ | | At the time of inspection, well ID sign and Es plan present. Share access road stable. Rig onsite actively drilling top hole on 3h, 2h and 1H previously drilled yet not in production. Secondary containment installed beneath rig as well as tanks. Tanks located onsite appear structurally sound. Bmp's installed and functioning according to ES plan. Presviously disturbed areas appear to be seeded and muclhed with observed growth. Operator shall continue to monitor and maintain all bmp's until final/permanent restoration is achieved. | ||
+ | |||
+ | Noted that sediment trap located behind well site appears full--left Chevron Rep Curtis Small message regarding possible cleanout of sediment trap. As with last inspection, waters contained in sediment trap appear "black"- samples taken no anomalies found; therefore, discoloration believed to be result of decomposition of materials. No violations noted during this inspection. | ||
+ | |||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2020357 | ||
+ | | 2011-11-17 | ||
+ | | No Violations Noted | ||
+ | | At the time of inspection, no E&S or IW discharge issues at the site. Site sign and E&S plan present. Well head located in secure fence. | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2020380 | ||
+ | | 2011-11-15 | ||
+ | | No Violations Noted | ||
+ | | At the time of inspection, no E&S or IW discharge issues at the site. Site sign and E&S plan present. Well head located in secure fence. | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1978954 | ||
+ | | 2011-06-01 | ||
+ | | No Violations Noted | ||
+ | | spud 5/27/11. sign present, ¿PMG RABY UNIT LEASE.¿ Unable to clearly located 2H permit number on sign or ES plan. Recommend that operator ¿clearly¿ identify well site with multiple permit numbers for each horizontal well being drilled as well as update ES plan to include each well. Temporary containment pad being installed. Rig onsite Appears temporary BMPs are installed&functioning according to plan. Observed sediment trap appeared full, recommend operator continue to monitor & maintain as necessary. No accelerated erosion or sedimentation issues noted, but did observed some (red) discoloration of soil* located behind job trailers and along soil pile; no active discharge or release of fluids observed during this inspection. Due to recent heavy rains and mulch onsite, a follow inspection will be conducted next week to further investigate/monitor/sample area of discoloration if observations illustrate a necessity to do so. No violations noted during this inspection. | ||
+ | |||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1979806 | ||
+ | | 2011-06-08 | ||
+ | | No Violations Noted | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1985941 | ||
+ | | 2011-06-29 | ||
+ | | No Violations Noted | ||
+ | | At the time of inspection, no E&S or IW discharge issues at the site. Conductor pipe (20¿) set at 60 ft with 9 yds3 cement (Gas Block) grouted. Second Stringer (13 3/8¿) pipe ran to 590 ft with 415 sks gas block with 9 bbl returns. Third stringer (9 5/8) set at 1805 ft with 561 sks of gas block with 25 bbl return. Current depth was at 12,374 ft. Kick of was 8859 ft. Mud weight was at 12.5. Chief was planning to set pipe and cement on 7/2/11. | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1985993 | ||
+ | | 2011-06-28 | ||
+ | | No Violations Noted | ||
+ | | At the time of inspection, no E&S or IW discharge issues at the site. Conductor pipe (20¿) set at 60 ft with 9 yds3 cement (Gas Block) grouted. Second Stringer (13 3/8¿) pipe ran to 590 ft with 415 sks gas block with 9 bbl returns. Third stringer (9 5/8) set at 1805 ft with 561 sks of gas block with 25 bbl return. Current depth was at 11,292 ft. UDI process of pulling drilling rods. | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1986004 | ||
+ | | 2011-06-21 | ||
+ | | No Violations Noted | ||
+ | | At the time of inspection, no E&S or IW discharge issues at the site. Conductor pipe (20¿) set at 60 ft with 9 yds3 cement (Gas Block) grouted. Second Stringer (13 3/8¿) pipe ran to 590 ft with 415 sks gas block with 9 bbl returns. Current depth was at 4826 ft. Chief set 9 5/8 at 1805 ft with 561 sks of gas block with 25 bbl return. Proposed KOP was at 8859 ft.. Meeting held with Highland water sewer and Chief representatives. | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1986039 | ||
+ | | 2011-06-09 | ||
+ | | No Violations Noted | ||
+ | | At the time of inspection, no E&S or IW discharge issues at the site. Conductor pipe (20¿) set at 60 ft with 9 yds3 cement (Gas Block) grouted. Second Stringer (13 3/8¿) pipe ran to 590 ft with 415 sks gas block with 9 bbl returns. Current depth was at 988 ft. Chief proposed to set 9 5/8 at 1800 ft. Chief ran cement bond logs on each cement job. | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1986051 | ||
+ | | 2011-06-01 | ||
+ | | No Violations Noted | ||
+ | | At the time of inspection, no E&S or IW discharge issues at the site. Site located at the wind farm located in Adams Twp, Gallitzin State Park. Security guard present. Inspected site. Site sign and E&S plan present. Chief setting up UDI 60 rig. Alternate plan approved by PADEP for 2H well. | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2049816 | ||
+ | | 2012-03-01 | ||
+ | | No Violations Noted | ||
+ | | At the time of inspection, no E&S issues were present at the site. Site sign and E&S plan were present. Gas well is not in production. | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2058699 | ||
+ | | 2012-04-03 | ||
+ | | No Violations Noted | ||
+ | | At the time of inspection, no E&S issues were present at the site. Site sign and E&S plan were present. Gas well is not in production. | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2067286 | ||
+ | | 2012-05-01 | ||
+ | | No Violations Noted | ||
+ | | At the time of inspection, no E&S issues were present at the site. Site sign and E&S plan were present. Gas well is not in production. | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 2093081 | ||
+ | | 2012-06-12 | ||
+ | | No Violations Noted | ||
+ | | At the time of inspection, no E&S issues were present at the site. Site sign and E&S plan were present. Gas well is not in production. | ||
+ | | | ||
+ | |- | ||
+ | |} | ||
== Production Data == | == Production Data == | ||
− | { | + | {| class="wikitable sortable" width="95%" |
+ | !scope="col" | PERIOD | ||
+ | !scope="col" | GAS QUANTITY | ||
+ | !scope="col" | GAS PRODUCTION DAYS | ||
+ | !scope="col" | CONDENSATE QUANTITY | ||
+ | !scope="col" | CONDENSATE PRODUCTION DAYS | ||
+ | !scope="col" | OIL QUANTITY | ||
+ | !scope="col" | OIL PRODUCTION DAYS | ||
+ | |- | ||
+ | | 2012-2 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | |- | ||
+ | |- | ||
+ | | 2012-1 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | |- | ||
+ | |- | ||
+ | | 2011-2 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | |- | ||
+ | |- | ||
+ | | 2011-2 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | |- | ||
+ | |- | ||
+ | | 2011-1 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | |- | ||
+ | |} | ||
== Waste Data == | == Waste Data == | ||
− | { | + | {| class="wikitable sortable" width="95%" |
+ | !scope="col" | PERIOD | ||
+ | !scope="col" | TYPE | ||
+ | !scope="col" | QUANTITY | ||
+ | !scope="col" | UNITS | ||
+ | !scope="col" | DISPOSAL METHOD | ||
+ | !scope="col" | WASTE FACILITY PERMIT ID | ||
+ | !scope="col" | WASTE FACILITY NAME | ||
+ | !scope="col" | FACILITY CITY | ||
+ | !scope="col" | FACILITY STATE | ||
+ | |- | ||
+ | | 2011-1 | ||
+ | | DRILLING FLUID WASTE | ||
+ | | style="text-align:right;" | 2890.0 | ||
+ | | Bbl | ||
+ | | LANDFILL | ||
+ | | NY STATE #32S11 | ||
+ | | ALLIED WASTE SYSTEMS | ||
+ | | NIAGARA FALLS | ||
+ | | NY | ||
+ | |- | ||
+ | |- | ||
+ | | 2011-1 | ||
+ | | DRILL CUTTINGS | ||
+ | | style="text-align:right;" | 1006.43 | ||
+ | | Tons | ||
+ | | LANDFILL | ||
+ | | 100081 | ||
+ | | WASTE MANAGEMENT, INC - SOUTHERN ALLEGHENIES | ||
+ | | DAVIDSVILLE | ||
+ | | PA | ||
+ | |- | ||
+ | |- | ||
+ | | 2011-2 | ||
+ | | FRACING FLUID WASTE | ||
+ | | style="text-align:right;" | 80.0 | ||
+ | | Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | EPA ID: 748-163 | ||
+ | | PATRIOT WATER TREATMENT | ||
+ | | WARREN | ||
+ | | OH | ||
+ | |- | ||
+ | |} | ||
__NOEDITSECTION__ | __NOEDITSECTION__ |
Well ID: 021-21176 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.281483,"lon":-78.690058,"icon":""}]} |
County: Cambria | |
Municipality: Adams Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Farm/Lease Name: PMG RABY UNIT 2H | |
First Permit Date: 2011-03-29 | |
Last Permit Date: 2011-03-29 | |
Spud Date: 2011-05-27 | |
Unconventional: Yes | |
Horizontal: Yes | |
Producing: No | |
Violations: None | |
Latitude: 40.281483 | |
Longitude: -78.690058 |
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID |
---|---|---|---|---|
2004426 | 2011-09-13 | No Violations Noted | During this inspection, Chevron Regulatory Compliance Personnel and WQS Marc Maestra present. Well ID sign, ES plan onsite. Well tag present. Site gated and locked. Well drilled not yet in production. Access road and entrance adequately rocked. Soil pile seeded/mulched. Slopes secured with erosion blankets exhibiting growth. BMPs installed according to plan.no accelerated erosion or sedimentation issues noted. Although red staining near soil pile and near toe slope of pad is observed-again this was attributed to decomposition of mulch/ tress used during pad construction. While on site all parties noted that soil near sediment trap appears discolored with a ¿red/black¿ hue and the liquid contents of sediment trap appear dark in nature as well- it is also observed that large quantity of leaves present in trap. Operator plans to investigate/sample discoloration of both the soil and liquid fraction from near sed trap. 10-20-11: Bases on site inspection and review of operator results it does not appear discoloration is due to spill or release. | |
2016194 | 2011-11-01 | No Violations Noted | At the time of inspection, no E&S or IW discharge issues at the site. Site sign and E&S plan present. Well marker not present. Spud called on 10/31/11. Called Chevron to request well marker placed prior to drilling activity. | |
2020137 | 2011-11-17 | No Violations Noted | At the time of inspection, well ID sign and Es plan present. Share access road stable. Rig onsite actively drilling top hole on 3h, 2h and 1H previously drilled yet not in production. Secondary containment installed beneath rig as well as tanks. Tanks located onsite appear structurally sound. Bmp's installed and functioning according to ES plan. Presviously disturbed areas appear to be seeded and muclhed with observed growth. Operator shall continue to monitor and maintain all bmp's until final/permanent restoration is achieved.
Noted that sediment trap located behind well site appears full--left Chevron Rep Curtis Small message regarding possible cleanout of sediment trap. As with last inspection, waters contained in sediment trap appear "black"- samples taken no anomalies found; therefore, discoloration believed to be result of decomposition of materials. No violations noted during this inspection. |
|
2020357 | 2011-11-17 | No Violations Noted | At the time of inspection, no E&S or IW discharge issues at the site. Site sign and E&S plan present. Well head located in secure fence. | |
2020380 | 2011-11-15 | No Violations Noted | At the time of inspection, no E&S or IW discharge issues at the site. Site sign and E&S plan present. Well head located in secure fence. | |
1978954 | 2011-06-01 | No Violations Noted | spud 5/27/11. sign present, ¿PMG RABY UNIT LEASE.¿ Unable to clearly located 2H permit number on sign or ES plan. Recommend that operator ¿clearly¿ identify well site with multiple permit numbers for each horizontal well being drilled as well as update ES plan to include each well. Temporary containment pad being installed. Rig onsite Appears temporary BMPs are installed&functioning according to plan. Observed sediment trap appeared full, recommend operator continue to monitor & maintain as necessary. No accelerated erosion or sedimentation issues noted, but did observed some (red) discoloration of soil* located behind job trailers and along soil pile; no active discharge or release of fluids observed during this inspection. Due to recent heavy rains and mulch onsite, a follow inspection will be conducted next week to further investigate/monitor/sample area of discoloration if observations illustrate a necessity to do so. No violations noted during this inspection. | |
1979806 | 2011-06-08 | No Violations Noted | ||
1985941 | 2011-06-29 | No Violations Noted | At the time of inspection, no E&S or IW discharge issues at the site. Conductor pipe (20¿) set at 60 ft with 9 yds3 cement (Gas Block) grouted. Second Stringer (13 3/8¿) pipe ran to 590 ft with 415 sks gas block with 9 bbl returns. Third stringer (9 5/8) set at 1805 ft with 561 sks of gas block with 25 bbl return. Current depth was at 12,374 ft. Kick of was 8859 ft. Mud weight was at 12.5. Chief was planning to set pipe and cement on 7/2/11. | |
1985993 | 2011-06-28 | No Violations Noted | At the time of inspection, no E&S or IW discharge issues at the site. Conductor pipe (20¿) set at 60 ft with 9 yds3 cement (Gas Block) grouted. Second Stringer (13 3/8¿) pipe ran to 590 ft with 415 sks gas block with 9 bbl returns. Third stringer (9 5/8) set at 1805 ft with 561 sks of gas block with 25 bbl return. Current depth was at 11,292 ft. UDI process of pulling drilling rods. | |
1986004 | 2011-06-21 | No Violations Noted | At the time of inspection, no E&S or IW discharge issues at the site. Conductor pipe (20¿) set at 60 ft with 9 yds3 cement (Gas Block) grouted. Second Stringer (13 3/8¿) pipe ran to 590 ft with 415 sks gas block with 9 bbl returns. Current depth was at 4826 ft. Chief set 9 5/8 at 1805 ft with 561 sks of gas block with 25 bbl return. Proposed KOP was at 8859 ft.. Meeting held with Highland water sewer and Chief representatives. | |
1986039 | 2011-06-09 | No Violations Noted | At the time of inspection, no E&S or IW discharge issues at the site. Conductor pipe (20¿) set at 60 ft with 9 yds3 cement (Gas Block) grouted. Second Stringer (13 3/8¿) pipe ran to 590 ft with 415 sks gas block with 9 bbl returns. Current depth was at 988 ft. Chief proposed to set 9 5/8 at 1800 ft. Chief ran cement bond logs on each cement job. | |
1986051 | 2011-06-01 | No Violations Noted | At the time of inspection, no E&S or IW discharge issues at the site. Site located at the wind farm located in Adams Twp, Gallitzin State Park. Security guard present. Inspected site. Site sign and E&S plan present. Chief setting up UDI 60 rig. Alternate plan approved by PADEP for 2H well. | |
2049816 | 2012-03-01 | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Site sign and E&S plan were present. Gas well is not in production. | |
2058699 | 2012-04-03 | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Site sign and E&S plan were present. Gas well is not in production. | |
2067286 | 2012-05-01 | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Site sign and E&S plan were present. Gas well is not in production. | |
2093081 | 2012-06-12 | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Site sign and E&S plan were present. Gas well is not in production. |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
2012-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2012-1 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-1 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|---|---|---|---|---|---|---|---|
2011-1 | DRILLING FLUID WASTE | 2890.0 | Bbl | LANDFILL | NY STATE #32S11 | ALLIED WASTE SYSTEMS | NIAGARA FALLS | NY |
2011-1 | DRILL CUTTINGS | 1006.43 | Tons | LANDFILL | 100081 | WASTE MANAGEMENT, INC - SOUTHERN ALLEGHENIES | DAVIDSVILLE | PA |
2011-2 | FRACING FLUID WASTE | 80.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 | PATRIOT WATER TREATMENT | WARREN | OH |