If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
== Well Details =={| class="wikitable welldetails" width="95%"| Well ID: 47-087-01723| style="height=100%; align=center" rowspan="15" |
|-| County:|-| Municipality:|-| Operator Name: PAULEY, JOSEPH E|-| Well Pad ID:|-| Farm/Lease Name: HARPER, BELLE|-| First Permit Date:|-| Last Permit Date: 1969-10-27|-| Spud Date: 1969-08-15|-| Unconventional:|-| Horizontal:|-| Producing: Yes|-| Violations: 0|-| Latitude: 38.663711|-| Longitude: -81.358895|-|}== Production Data =={| class="wikitable sortable" width="95%"!scope="col" | PERIOD!scope="col" | GAS QUANTITY!scope="col" | GAS PRODUCTION DAYS!scope="col" | CONDENSATE QUANTITY!scope="col" | CONDENSATE PRODUCTION DAYS!scope="col" | OIL QUANTITY!scope="col" | OIL PRODUCTION DAYS|}== Waste Data =={| class="wikitable sortable" width="95%"!scope="col" | PERIOD!scope="col" | TYPE!scope="col" | QUANTITY!scope="col" | UNITS!scope="col" | DISPOSAL METHOD!scope="col" | WASTE FACILITY PERMIT ID!scope="col" | WASTE FACILITY NAME!scope="col" | FACILITY CITY!scope="col" | FACILITY STATE|}== Inspection Data =={| class="wikitable sortable" width="95%"!scope="col" | INSPECTION ID!scope="col" | DATE!scope="col" | DESCRIPTION!scope="col" | COMMENT!scope="col" | VIOLATION ID|-|| 2008-10-22|| 0 Flow 0 Pressure||-|-|| 2004-09-27|| well out of service||-|-|| 2000-08-28|| well is active on flow or preasure at time of inspection||-|-|| 1999-06-22|| ZERO INJ. PRESS; WELL NOT INJ. AT INSP.; NO FLOW OR PRESS. ON ANNULUS||-|-|| 1998-08-12|| VACUUM SYSTEM; NO FLOW OR PRESSURE ON ANNULUS||-|-|| 1997-08-19|| G. SMITH PRESSURE TEST TUBING ANNULUS TO 1000PSI. 50 BLED OFF. TEST GOOD||-|-|| 1997-07-01|| NEW TANK BEING SET - WELL NOT INJECTNG - NEW LINE BEING RUN TANK TO WELL||-|-|| 1996-09-20|| ZERO PSI ON 2 3/8"; INJ. RATE 10 BBL/HR; NO FLOW OR PRESSURE ON ANNULUS||-|-|| 1995-09-08|| 2 3/8" ON VACUUM; INJ. RATE 14 BBL/HR; NO FLOW OR PRESSURE ON ANNULUS||-|-|| 1994-06-27|| 2 3/8" ON VACUUM; INJ. RATE 14 BBL/HR; NO FLOW OR PRESS. ON ANNULUS||-|-|| 1993-09-22||||-|-|| 1992-08-13|| CO. NEEDS TO INSTALL GAUGE; NO FLOW OR PRESSURE ON ANNULUS||-|-|| 1992-08-13|| G.SMITH-PRESSURE TEST 2 3/8 X 4 1/2 TO 1000 PSI/20 MIN. PSI BLEED OFF||-|-|| 1990-07-03|| 175 PSI AT PUMPHOUSE. NO FLOW OR PRESSURE ON ANNULUS.||-|-|| 1989-03-30|| TAKING WATER ON VACUUM.||-|-|| 1987-08-06|| H. DAUGHERTY - P. TESTED 2 3/8" ANNULUS WITH NITROGEN FOR 20 MIN. PASSED||-|-|| 1987-07-28|| SHOT F. LEVEL ON 2 3/8"ANNULUS BEF. & AFT. INJ. WATER AT 288 FT. ON BOTH||-|-|| 1985-06-24|| FAILURE TO SUBMIT MONTHLY REPORTS. ABATED.||-|-|| 1970-01-15|| RELEASED.||-|}