Well ID: 34-069-20067
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1999-05-10
Unconventional:
Horizontal:
Producing: No
Violations: 8
Latitude: 41.3301103036
Longitude: -83.9657561558

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1296123606 2012-01-04 No change from last inspection. NOV's from last inspection on 8/5/2011 still need resolved.
-1393011145 2009-10-15 Inspection report to terminate NOV.
-1616746435 2005-11-08 Spoke to operator Tony on site. The well is being converted back to a production well. A temporary bridge plug has been placed in the well. Spoke to John Hunter by phone. A well completion form must be submitted to indicate the changes made to the well. The form should also indicate that the well is no longer being used as an injection well.
-1869841307 2003-07-02 Met on site with Tony Krieder to check pressure on the well since previous inspection showed injection and annulus pressure at equilibrium. Pressure was checked before any changes were made to well. Pessure on injection side showed 135 psi on both inspector and operator gauge. Pressure on annulus side showed 125 psi on both inspector and operator gauge. Tony indicated that injection pressure fluctuates and annulus pressure drops about 5 psi when gauges are attached/removed. This would account for equal pressures noted at previous inspection. Annulus pressure was dropped to 75 psi to avoid confusion in the future. Thank you for your cooperation in this matter.
-2024735190 2011-08-08 Well located in corn field. No lane to well. No production records since 2000. 8" withcasing head, 4.5" with casing head, tubing, and rods. No pumpjack on well. No I.D. on well. 9-9-05(A)10
-2024735190 2011-08-08 Well located in corn field. No lane to well. No production records since 2000. 8" withcasing head, 4.5" with casing head, tubing, and rods. No pumpjack on well. No I.D. on well. NONE_
-2024735190 2011-08-08 Well located in corn field. No lane to well. No production records since 2000. 8" withcasing head, 4.5" with casing head, tubing, and rods. No pumpjack on well. No I.D. on well. NONE9
-2024735190 2011-08-08 Well located in corn field. No lane to well. No production records since 2000. 8" withcasing head, 4.5" with casing head, tubing, and rods. No pumpjack on well. No I.D. on well. NONEC
1046727616 2003-03-03 Main valve from the flow line shut in. No ID at well head. NONE(H)
1047484310 2003-03-03 Checked tank battery site and injection well with Jeff Fry. Checked pressure at well. Pressure at injection side was 140 lbs and annulus pressure was 80 lbs. Request operator to install 1/4 inch needle valve at 2 inch baylon valve. This would be safer when checking pressure and would release less annulus pressure. There was no well identification at the injection well site. A sign must be posted which includes company name, phone number, permit number, lease name, township and county. The sign should be posted by 3/25/03. NONE(H)
1051101872 2003-04-23 Sign posted at wellhead. Chiefs Order for failure to post sign will be terminated. Valves to check annulus and injection pressure are 1/2 inch fittings. Gauge to check pressures require 1/4 inch fittings. The valves and fittings to check annulus and injection pressure must be in good working order. This is important so chance for damage to wellhead is minimized during inspection. Install 1/4 inch valve at annulus and injection monitoring locations. Could not check pressure at well. No gauges attached to wellhead. Noted gauge with 2 inch fitting next to wellhead. 9-3-05(A)3
1052162025 2003-04-23 Sign posted at wellhead. Notice of Violation for failure to post sign will be terminated. Valves and fittings to check annulus and injection pressure are 1/2 inch fittings. Gauge to check pressure requires 1/4 inch fittings. The valves and fittings to check annulus and injection pressure must be in good working order. This is important so chance for damage to wellhead is mininmized during inspection. Install 1/4 inch valve at annulus and injection monitoring locations. Could not check pressure at well. No gauges attached to wellhead. Noted gauge with 2 inch fitting at wellhead. 9-5-09(A)(3)
1054755355 2003-06-04 Company has installed 1/4 inch valves as requested per NOV.

Checked annulus and injection pressure at well. Annulus and injection pressure were both 130 lbs. This may indicate an integrity problem with the well. Request operator contact inspector at 937-599-1445 for field test of pressure on the well.

1055772995 2003-06-04 Checked injection well with Jeff Fry. New valves were installed with 1/4 inch fittings on annulus and injection pipes. NOV will be terminated. Pressure check on annulus and injection show pressure at equalibrium. Inspection on 3/3/03 showed injection pressure 140 and annulus pressure 80. A problem may have developed with the well since pressures are now equal. Spoke to Tony Krieder by phone. He indicated that the well was not cuurently being used for injection. Requested that Tony contact the inspector for on site inspection to check well together. If a problem has developed with the well, it will need to be repaired or plugged.
1065615502 2003-10-08 Checked pressure at well. Injection pressurewas 150 psi and annulus pressure was 85 psi. No problems noted.
1071581320 2003-12-16 Checked pressure at well site. Injection side 140 psi. Annulus side 80 psi. ID sign posted at well. No problems noted.
1077729186 2004-02-25 Sign posted. Annulus pressure 100 psi and injection pressure 125 psi.
1084470177 2004-05-12 Well surrounded by crops. Injection pressure 130 psi, annulus pressure 100 psi. No problems noted.
1089911202 2004-07-15 Sign posted. Injection pressure 130 psi, annulus pressure 150 psi.
1095965504 2004-09-23 Sign posted. Injection pressure 125 psi. Annulus pressure 220 psi.
1096379791 2004-09-28 Met with consultants Dean Franks and John Dooley in preparation of resuming well production and brine injection. Operation has been inactive for over 2 years. The tank battery located at the scrubber plant is not properly diked. There are two 400 barrel brine tanks and one 300 barrel oil tank. There is a plastic liner (approximately 200 mils) under the tanks. A dike with an impermeable liner, which is capable of containing the contents of the combined tank capacity, must be constructed around the tank battery before production resumes. Request inspector be notified when dike construction completed.
1100618458 2004-11-16 Reviewed construction of dike and liner for brine tanks for injection well. Dike appears to be constructed to design submitted. Liner overlaps dike and is being cover with dirt and stone to keep liner in place. No pressure readings taken at wellhead this day. Spoke to Tony Krieder by phone (419-748-8226). He anticipated that operations may resume in the next month.
1104942525 2005-01-05 Spoke to operator Tony and Aurora employee Mark at gas plant before inspection. Production has not yet resumed. Drilling for new injection well will probably be started in a few weeks. Checked pressure on existing injection well.
1112194794 2005-03-30 Checked pressure on injection well. Injection pressure was 110 psi and annulus pressure was 575 psi. Permit allows for maximum injection pressure of 500 psi, however the annulus pressure is not resticted to this maximum psi.
1118945984 2005-06-16 Checked pressure on well. Annulus side showed 650psi and injection side 180 psi. ID sign posted.
1126558954 2005-09-12 Checked well for pressure. Annulus side shows 660 psi while injection side was 330 psi. Spoke to operator about well use since new injection well is now in service. Operator will decide if to change to production well or plug.
1135879940 2005-12-27 This well now appears to be a production well as noted by the pumpjack operating on the well. Phone conversation with John Hunter on 11/8/05 requested that a well completion form be submitted to the Columbus office indicating a change in the status of the well from injection to production. No correspondence has been received from the operator regarding this change and should be submitted ASAP. If you have any questions, please contact inspector at 419-599-0058.
1191531076 2007-10-04 Sign posted at well is for previous company. New ID sign needs to be posted. No injection pressure but annulus pressure at 480 psi. New gauges on well.
1302622957 2011-04-12 Check on status of NOV that I received after Ken retired. It is not clear that the NOV is still valid, it may have been resolved previously by inspector Pispanin. The well has been converted back to a production well. The well does not appear to have been produced for some time, due to the conditions at the well site. Overgrown with weeds and no lease road. The gas plant and injection facilities have been shut down. An attempt to contact the company was unsuccessful. The phone numbers given in RBDMS are no longer valid.
13385 PASSED Y WITNESSED 8/4/94 INSPECTOR FAUST, SAMUEL E. DATE 08/0419/94 DATA FROM OLD VAX INFO
13386 PASSED Y WITNESSED 5/18/93 INSPECTOR DATE 05/1819/93 DATA FROM OLD VAX INFO
34073717 2002-08-21 Preliminary restoration done.
353113520 2013-01-31 At the time of the inspection the well was shut. There was 0 psi on the annulus gauge and no gauges on the production lines. There were no signs of any leaks. The corrective action from the Compliance Notice issued in 2011 has not been completed. The inspection was done at the request of Eric Vendel from The Ohio Division of Oil and Gas.
6973513 2001-08-23 Small injection pump running at this time. Could not chk annulus pressure, no 1/4 inch tap for my gauge.