X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-011-20101

Well Details

Well ID: 34-011-20101
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2007-04-30
Unconventional:
Horizontal:
Producing: No
Violations: 0
Latitude: 40.5427938954
Longitude: -84.3608915328

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-135247237 2010-09-30 Check well and storage.

Id posted by the well head. The well is set up for gas porduction, no pumping unit on the well.

-292767442 2007-05-02 New well being drilled by R&S Drlg. Out of Indiana. Jack Racer rig operator. Drilling for Hunt Petroleum Corp. Danny Price company rep on site. Ingersol Rand rig drilling on air @ 170'. Top of lime @ 40' , set 60' of 8 5/8 for conductor and cemented in. New 7' casing on site for surface. Will probably do surface tomorrow morning. Told Jack to install permit liner after surface casing set. Went over regulations.
-898383036 2013-04-04 At the time of the inspection the well had been bailed down to 550', 100' below the surface casing, and filled from the surface with approximately 4 yards of 9 sack grout from St. Henry Tile Co.
-916243540 2007-05-03 Surface casing set at 453 feet.
1167815440 2011-06-16 I inspected the well location with Brent Bear. See Bear's report for details.
1194455112 2007-11-07 Chk well and storage, Ok. No gas odors at this time. The valve on the production line at the tank is closed. Preliminary restoration is done. No identification posted.

Storage tank is a rented portable 500 bbl frack tank.

1209567623 2008-04-30 Preliminary Restoration done.
1210870481 2008-05-15 Chk well and storage.

> Frack tank has been removed, no storage facilities. No gas line hook up. > Lease road has been plowed up with the rest of the field in preparation for the planting of agricultural crops.

1238537485 2012-12-14 At the time of my inspection the well was not in production and needs serviced.
1260286747 2013-03-22 At the time of the inspection a bottom plug was set in the well from 1175' to 850' with 45 sacks of 50/50 pozmix from PetroSet Cementing Services.
1264439392 2010-01-25 The well is not in production at this time. A dike has been built to the south of the well impropriation for the installation of storage facilities. A salt water injection well is going to be drilled in the near future.
1265038705 2010-02-01 On site by request of Chuck Knox. (Co rep.) to witness the installation of facilities for salt water injection. The well will be an offset of the present production well. The injection storage and production storage will be in the same diked area. The liner has been layed down and is being covered with sand.
1323180974 2011-11-21 Well is shut in and being serviced. Tubing laying on ground. ID posted.
1360332618 2013-01-30 At the time of my inspection the well was shut in and no longer in production. Mark Amell of Amell Inc. was hired to oversee the plugging of the well for Innex Oil and Gas Inc.
1660300502 2010-08-25 On site to check on report of gas odors. No odors at the storage tank but has a definite odor by the flair tube. The tube is warm indicating that the flair or pilot light is burning in side of the tube. Called and Talked to Bob Huwer he is taking care of the well and said that he has an automatic spark in the tube to light the gas. The storage tanks are plummed into an inclosed system that goes to the flair. He asked that I give the neighbors his phone number to call him when they get the odors. Then he will go to the site and try to determin what the problem is so he can fix it.
1933875905 2013-03-26 At the time of the inspection the bottom plug was tagged with the bailer at 850'. The well was then bailed down 550' for the next plug.
2039287590 2011-06-16 An inspection conducted with Will Ziegler revealed that the Pre-liminary Restoration meets ORC 1509.072. No violations were noted.
543064519 2013-01-17 At the time of my inspection the well is shut in with the intention to plug and abandon the well.
642206933 2013-01-12 At the time of my inspection the well has been shut down and shut in due to the release from the tank battery associated with Complaint # 4186. The well will remain shut in until it is plugged along with the two other wells on location.
756545476 2013-05-21 At the time of the inspection all plugging operation were completed and all equipment had been removed from the location. The location is in a farm field and was graded by the plugging contractor. The location was tilled and planted by the landowner. Final Restoration Passed.