37-005-26962

Well Details

Well ID: 37-005-26962
Loading map...
Operator Name: SNYDER BROS INC
First Permit Date: 2002-08-15
Last Permit Date: 2002-08-15
Spud Date: 2003-07-16
Unconventional: No
Horizontal: No
Violations: None
Latitude: 40.739412
Longitude: -79.265984

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2013-0 4156.0 340.0 0.0 0.0 0.0 0.0
2012-0 5916.0 355.0 0.0 0.0 0.0 0.0
2011-0 4527.0 228.0 0.0 0.0 0.0 0.0
2010-0 2322.0 152.0 0.0 0.0 0.0 0.0
2009-0 1910.0 128.0 0.0 0.0 0.0 0.0
2008-0 453.0 51.0 0.0 0.0 0.0 0.0
2007-0 188.0 365.0 0.0 0.0 0.0 0.0
2006-0 5883.0 292.0 0.0 0.0 0.0 0.0
2005-0 8687.0 288.0 0.0 0.0 0.0 0.0
2004-0 12597.0 354.0 0.0 0.0 0.0 0.0
2003-0 838.0 19.0 0.0 0.0 0.0 0.0
2002-0 0.0 0.0 0.0 0.0 0.0 0.0

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2008-0 BRINE 45.0 Bbl REUSE OTHER THAN ROAD SPREADING NOT LISTED
2013-0 PRODUCED FLUID 35.0 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273 FLUID RECOVERY SERVICE JOSEPHINE FACILITY JOSEPHINE PA

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID
1253084 2003-07-15 Violation(s) Noted staked - site&access made/inadequate plan & controls - accelerated E&S on road/stream crossing - no GP7 357597
1253084 2003-07-15 Violation(s) Noted staked - site&access made/inadequate plan & controls - accelerated E&S on road/stream crossing - no GP7 357597
1253084 2003-07-15 Violation(s) Noted staked - site&access made/inadequate plan & controls - accelerated E&S on road/stream crossing - no GP7 357598
1253084 2003-07-15 Violation(s) Noted staked - site&access made/inadequate plan & controls - accelerated E&S on road/stream crossing - no GP7 357598
1259164 2003-07-29 Violation(s) Noted Inspection in response to SR # 03-005-013.

Drilling complete and equipment removed. Pit freeboard not being maintained. Discharge to ground. Gas venting at 7"& 9 5/8" annulus. Inadequate implementation of E&S BMP's.

359966
1259164 2003-07-29 Violation(s) Noted Inspection in response to SR # 03-005-013.

Drilling complete and equipment removed. Pit freeboard not being maintained. Discharge to ground. Gas venting at 7"& 9 5/8" annulus. Inadequate implementation of E&S BMP's.

359966
1259164 2003-07-29 Violation(s) Noted Inspection in response to SR # 03-005-013.

Drilling complete and equipment removed. Pit freeboard not being maintained. Discharge to ground. Gas venting at 7"& 9 5/8" annulus. Inadequate implementation of E&S BMP's.

359967
1259164 2003-07-29 Violation(s) Noted Inspection in response to SR # 03-005-013.

Drilling complete and equipment removed. Pit freeboard not being maintained. Discharge to ground. Gas venting at 7"& 9 5/8" annulus. Inadequate implementation of E&S BMP's.

359967
1259164 2003-07-29 Violation(s) Noted Inspection in response to SR # 03-005-013.

Drilling complete and equipment removed. Pit freeboard not being maintained. Discharge to ground. Gas venting at 7"& 9 5/8" annulus. Inadequate implementation of E&S BMP's.

359968
1259164 2003-07-29 Violation(s) Noted Inspection in response to SR # 03-005-013.

Drilling complete and equipment removed. Pit freeboard not being maintained. Discharge to ground. Gas venting at 7"& 9 5/8" annulus. Inadequate implementation of E&S BMP's.

359968
1259213 2003-07-31 No Violations Noted Re-inspection in response to violations documented 7-29-03.

Inspection conducted with WQS Ed Renwick and operator rep. Dave O'Hara. Freeboard restored. Plan for defective casing and/or cementing is to cement 4 1/2" CASING TO Surface.

1288348 2003-11-18 No Violations Noted equipped/E&S ok - graded-emerg veg/tank&tag ok/GP's issued
1378124 2004-09-16 No Violations Noted equipped/restored/tank&tag ok

References