37-129-28705

Well Details

Well ID: 37-129-28705
Loading map...
County: Westmoreland
Municipality: Derry Township
Operator Name: WPX ENERGY APPALACHIA LLC
Well Pad ID: 148108
Farm/Lease Name: CORBETT SOUTH 1-6H
First Permit Date: 2011-11-15
Last Permit Date: 2011-11-15
Spud Date: 2011-11-28
Unconventional: Yes
Horizontal: Yes
Producing: Yes
Violations: None
Latitude: 40.400938
Longitude: -79.275919

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID
2022004 2011-11-28 No Violations Noted
2024542 2011-12-02 No Violations Noted Site visit was part of spud notification.

Pad and impoundment were constructed. BMPs were installed as per plans. Slopes were seed and mulched and had obtained vegetative growth. Rigs was being trucked in. Secondary containtment was being installelled. Site plan, E&S plan, and site specific PPC plan were all in mailbox. No sign was currently installed. An email was sent to Randy Reimold requesting one be posted. No violations noted at this time.

2026855 2011-12-13 No Violations Noted HORIZONTAL MARCELLUS

WILLIAMS PAD W/H&P RIG 287 DRILLING AT DEPTH OF 4451'. E&S, PITS, AND HOUSE KEEPING GOOD

2029349 2011-12-23 No Violations Noted Site inspection performed as a follow-up to spill of synthetic drilling mud to the containement on the well pad. The spill had been cleaned up as of the time of the inspection. Erosion controls had been implemented properly and there was no accelerated erosion or sedimentation in relation to the access road or well-site. Disturbed area had been temporarily stabilized. Well stimulation impoundment located onsite. Impoundment conatined fluids and ad more than the required two feet of lined freeboard.
2030591 2011-12-23 No Violations Noted HORIZONTAL MARCELLUS

WILLIAMS PAD W/H&P RIG 287 DRILLING AT DEPTH OF 13900'. RAN 5.5CSG. TO 13882. E&S, PITS, AND HOUSE KEEPING GOOD

2034891 2012-01-17 No Violations Noted H&P Rig 287 was running at time of inspection. Fred Webb was the company man. Mr. Webb and DEP walked the site. Two french drains were found leading from the pad into a drainage ditch. Both drains had a small amount of suds in their drainage. Mr. Webb closed the valve on the main drainage route leading from the protective diking effectively stopping the discharge of stormwater from the site.

Inspection of rig found chemical totes next to the compressors. These totes were placed on the edge of the secondary containment with their valves hanging over the non-containment part of the pad. Suds were visible beneath the valve of the tote containing soap. This is the most probable source of the contamination. Other areas of secondary containment were comprimised where trucks had driven over edges. Sample 0629735 was taken in the drainage ditch on the South corner of pad.

2037010 2012-01-17 No Violations Noted HORIZONTAL MARCELLUS

WILLIAMS PAD W/H&P RIG 287 DRILLING AT DEPTH OF 13900'. RAN 5.5CSG. TO 13882. E&S, PITS, AND HOUSE KEEPING GOOD

2037079 2012-01-25 No Violations Noted HORIZONTAL MARCELLUS

WILLIAMS PAD W/H&P RIG 287 DRILLING AT DEPTH OF 13900'. RAN 5.5CSG. TO 13882. E&S, PITS, AND HOUSE KEEPING GOOD

2037281 2012-01-24 No Violations Noted Site visit was follow-up to 1-17-12 inspection with violations. Fred Webb (WPX Company Man) was on-site.

No soapy discharge was visible. French drains were tied together and flowed via gravity to the impoundment. Totes were moved on containment. Various areas of the secondary containment were comprimised (ie berm was knocked down in various areas). H&P representative said those were to be corrected soon. A small amount of what appeared diesel fuel appeared to be spilled on the pad. The stone from that area was immediately excavated and played in a roll-off box for disposal. Site plans were inspected at entrance to site. There is no design for the small depression made to place roll of box for cement returns. This addition might constitute a major modification. The underdrains are also not marked on the plans. Preliminary sample (0629735) results do show surfactants in the water.

2051011 2012-03-16 No Violations Noted no violations noted.
2067608 2012-05-14 No Violations Noted Routine inspection no issues noted.
2088317 2012-08-02 No Violations Noted Routine inspection. No issues noted.

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2012-2 0.0 0.0 0.0 0.0 0.0 0.0
2012-1 0.0 0.0 0.0 0.0 0.0 0.0
2011-2 0.0 0.0 0.0 0.0 0.0 0.0

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2011-2 DRILL CUTTINGS 1561.69 Tons LANDFILL 100277 WESTMORELAND WASTE, LLC BELLE VERNON PA
2012-1 DRILL CUTTINGS 16.37 Tons LANDFILL 100277 WESTMORELAND WASTE, LLC BELLE VERNON PA

References