{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 34-167-27401 | | Well ID: 34-167-27401 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 39.41, -81.65 | width=100% | height=100% }} |
|- | |- | ||
− | | | + | | Country: United States |
|- | |- | ||
− | | | + | | State: Ohio |
|- | |- | ||
− | | Operator Name: [[CARPER WELL SERVICE]] | + | | County: [[Washington_County,_Ohio|Washington]] |
+ | |- | ||
+ | | Municipality: [[Barlow_Township,_Washington_County,_Ohio|Barlow Township]] | ||
+ | |- | ||
+ | | Operator Name: [[CARPER WELL SERVICE INC.]] | ||
|- | |- | ||
| Well Pad ID: | | Well Pad ID: | ||
|- | |- | ||
− | | Farm/Lease Name: | + | | Farm/Lease Name: DAVIS-HUFFMAN |
|- | |- | ||
− | | | + | | License Status: Active Injection |
|- | |- | ||
− | | | + | | License Date: 1989-05-03 |
|- | |- | ||
| Spud Date: 1983-01-07 | | Spud Date: 1983-01-07 | ||
|- | |- | ||
− | | | + | | Spud Drilling Contractor: [[SWANK-ULLMAN]] |
+ | |- | ||
+ | | Final Drill Date: 1983-01-10 | ||
+ | |- | ||
+ | | Well Total Depth: 1911.00 ft | ||
|- | |- | ||
| Configuration: Vertical | | Configuration: Vertical | ||
|- | |- | ||
− | | | + | | Latitude: 39.410000 |
|- | |- | ||
− | | | + | | Longitude: -81.650000 |
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables | ||
+ | |publisher = [[Ohio Department of Natural Resources]] | ||
+ | | date = 2020-11-16 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-11-16 }}</ref> | ||
+ | == Well History == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" style="text-align: center"| Well Status | ||
+ | !scope="col" style="width: 15%;text-align: center"| Well Status Date | ||
+ | !scope="col" style="text-align: center"| Comment | ||
|- | |- | ||
− | | | + | | CO |
+ | | 1982-12-30 | ||
+ | | 118 BIG INJUN OIL & GAS INC GeoDate 12/30/82 | ||
|- | |- | ||
− | | | + | | Oil and Gas |
+ | | 1982-12-30 | ||
+ | | Issued Date 12/30/82 Expired Date 6/28/83 Acres 0020000 Tool Type RTA Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000 | ||
+ | |- | ||
+ | | Original Spud | ||
+ | | 1983-01-07 | ||
+ | | CONVERT 12-15-84 | ||
+ | |- | ||
+ | | Completed | ||
+ | | 1983-01-10 | ||
+ | | CONVERT 12-15-84 | ||
+ | |- | ||
+ | | Reached Total Depth | ||
+ | | 1983-01-10 | ||
+ | | CONVERT 12-15-84 | ||
+ | |- | ||
+ | | CO | ||
+ | | 1984-12-13 | ||
+ | | 642 LOTHES OIL & GAS INC GeoDate 12/13/84 | ||
+ | |- | ||
+ | | Salt Water Injection Well | ||
+ | | 1984-12-13 | ||
+ | | Issued Date 12/13/84 Expired Date 6/11/85 Acres 0020000 Tool Type RTA Proposed Formation BEREA Proposed Depth 01911 Proposed Drill Depth 01911 | ||
+ | |- | ||
+ | | Storage Well | ||
+ | | 1984-12-13 | ||
+ | | Issued Date 12/13/84 Expired Date 6/11/85 Acres 0020000 Tool Type RTA Proposed Formation BEREA Proposed Depth 01911 Proposed Drill Depth 01911 | ||
+ | |- | ||
+ | | Completion Report Received | ||
+ | | 1986-02-13 | ||
+ | | CONVERT 12-15-84 | ||
+ | |- | ||
+ | | CO | ||
+ | | 1989-05-03 | ||
+ | | 3133 PETROEL GeoDate 5/3/89 | ||
+ | |- | ||
+ | | Conversion to Injector | ||
+ | | 1989-05-03 | ||
+ | | | ||
+ | |- | ||
+ | | Unknown | ||
+ | | 1989-05-03 | ||
+ | | Issued Date 5/3/89 Expired Date 5/3/90 Proposed Purpose SW Was Plug Supervised Who Superivsed Plug and Abandon Date | ||
+ | |- | ||
+ | | Construction Permit Expires | ||
+ | | 1990-05-03 | ||
+ | | CONVERT 12-15-84 | ||
+ | |- | ||
+ | | First Injection | ||
+ | | 1990-08-29 | ||
+ | | CONVERT 12-15-84 | ||
+ | |- | ||
+ | | Change of Owner | ||
+ | | 1998-06-15 | ||
+ | | Operator changed from 3133, PETROEL to 6158, JONES PERLEY E | ||
+ | |- | ||
+ | | Change of Owner | ||
+ | | 1999-02-03 | ||
+ | | Operator changed from 6158, JONES PERLEY E to 3133, PETROEL | ||
+ | |- | ||
+ | | Annulus Pressure Monitoring Approved | ||
+ | | 1999-06-10 | ||
+ | | CONVERT 12-15-84 | ||
+ | |- | ||
+ | | Change of Owner | ||
+ | | 2001-06-25 | ||
+ | | Operator changed from 3133, PETROEL to 7007, CARPER WELL SERVICE | ||
+ | |- | ||
+ | | Last Compliance Report | ||
+ | | 2015-06-11 | ||
+ | | CONVERT 12-15-84 | ||
+ | |- | ||
+ | | Record Last Modified | ||
+ | | 2017-10-19 | ||
+ | | CONVERT 12-15-84 | ||
|- | |- | ||
|} | |} | ||
− | == | + | For data sources see<ref>{{cite web |
+ | | title = Risk Based Data Management System - Well and WellHistry Tables | ||
+ | |publisher = [[Ohio Department of Natural Resources]] | ||
+ | | date = 2020-11-16 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-11-16 }}</ref> | ||
+ | == Perforation Treatments == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" style="text-align: center"| Perforation Date |
− | !scope="col" | | + | !scope="col" style="text-align: center"| Interval Top (ft) |
− | !scope="col" | | + | !scope="col" style="text-align: center"| Interval Base (ft) |
− | !scope="col" | | + | !scope="col" style="text-align: center"| Number of Shots |
− | + | |- | |
− | + | | 2000-05-09 | |
− | + | | style="text-align: right;" | 1811 | |
+ | | style="text-align: right;" | 1816 | ||
+ | | style="text-align: right;" | 4 | ||
+ | |- | ||
+ | | | ||
+ | | style="text-align: right;" | 1811 | ||
+ | | style="text-align: right;" | 1816 | ||
+ | | style="text-align: right;" | 4 | ||
|- | |- | ||
− | |||
− | |||
| | | | ||
− | | | + | | style="text-align: right;" | 1811 |
+ | | style="text-align: right;" | 1816 | ||
+ | | style="text-align: right;" | 4 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Risk Based Data Management System - Perfs Table | ||
+ | |publisher = [[Ohio Department of Natural Resources]] | ||
+ | | date = 2020-11-16 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-11-16 }}</ref> | ||
+ | <!--== Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" style="text-align: center"| Job Number | ||
+ | !scope="col" style="text-align: center"| Job Start Date | ||
+ | !scope="col" style="text-align: center"| Job End Date | ||
+ | !scope="col" style="text-align: center"| True Vertical Depth (ft) | ||
+ | !scope="col" style="text-align: center"| Total Water Volume (gal) | ||
+ | !scope="col" style="text-align: center"| Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | |}--> | ||
+ | <!--==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" style="width: 100%" | ||
+ | !scope="col" style="text-align: center"| Job Number | ||
+ | !scope="col" style="text-align: center"| Trade Name | ||
+ | !scope="col" style="text-align: center"| Supplier | ||
+ | !scope="col" style="text-align: center"| Purpose | ||
+ | !scope="col" style="text-align: center"| Ingredient Name | ||
+ | !scope="col" style="white-space: nowrap;text-align: center"| CAS Number | ||
+ | !scope="col" style="text-align: center"| Additive Percentage by Mass | ||
+ | !scope="col" style="text-align: center"| Job Percentage by Mass | ||
+ | !scope="col" style="text-align: center"| Mass Used (lb) | ||
+ | |- | ||
+ | |}--> | ||
+ | == Stimulations Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" style="text-align: center"| Stimulation Date | ||
+ | !scope="col" style="text-align: center"| Chemical Agent | ||
+ | !scope="col" style="text-align: center"| Chemical Agent Concentration (%) | ||
+ | !scope="col" style="text-align: center"| Fracking Fluid Volume | ||
+ | !scope="col" style="text-align: center"| Mass of Proppant Used (lb) | ||
+ | !scope="col" style="text-align: center"| Fracking Company | ||
+ | !scope="col" style="text-align: center"| Comments | ||
+ | |- | ||
| | | | ||
+ | | CO2 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 350 Bbl | ||
+ | | style="text-align: right;" | 10000 | ||
| | | | ||
− | | | + | | FRAC: 350 LBS OF LIQUID CO2, 150 GAL OF 15% ACID, AND 10,000 LBS OF SAND |
− | |||
|- | |- | ||
− | |||
− | |||
| | | | ||
− | | | + | | ACID |
+ | | style="text-align: right;" | 15 | ||
+ | | style="text-align: right;" | 150 Gal | ||
+ | | style="text-align: right;" | 0 | ||
| | | | ||
| | | | ||
− | |||
|- | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Risk Based Data Management System - tblStimulation Table | ||
+ | |publisher = [[Ohio Department of Natural Resources]] | ||
+ | | date = 2020-11-16 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-11-16 }}</ref> | ||
+ | <!--== Production Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" style="text-align: center"| Period | ||
+ | !scope="col" style="text-align: center"| Operator Name | ||
+ | !scope="col" style="text-align: center"| Gas Quantity (mcf) | ||
+ | !scope="col" style="text-align: center"| Oil Quantity (bbl) | ||
+ | !scope="col" style="text-align: center"| Production Days | ||
|- | |- | ||
− | | | + | |}--> |
− | | | + | <!--== Waste Data == |
+ | {| class="wikitable sortable" | ||
+ | !scope="col" style="text-align: center"| Period | ||
+ | !scope="col" style="text-align: center"| Operator Name | ||
+ | !scope="col" style="text-align: center"| Waste Type | ||
+ | !scope="col" style="text-align: center"| Quantity (bbl) | ||
+ | !scope="col" style="text-align: center"| Production Days | ||
+ | |- | ||
+ | |}--> | ||
+ | == Inspection Data == | ||
+ | ==== Inspections Performed ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" style="text-align: center"| Inspection ID | ||
+ | !scope="col" style="text-align: center"| Inspection Date | ||
+ | !scope="col" style="text-align: center"| Inspection Type | ||
+ | !scope="col" style="text-align: center"| Inspection Result | ||
+ | !scope="col" style="text-align: center"| Inspection Comments | ||
+ | |- | ||
+ | | -1014406206 | ||
+ | | 2011-11-23 0:00 | ||
+ | | SW | ||
+ | | No Violations | ||
+ | | 1.00 | ||
+ | |- | ||
+ | | -1082080785 | ||
+ | | 2005-5-18 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
+ | | | ||
+ | |- | ||
+ | | -1101186217 | ||
+ | | 2002-3-14 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
− | | | + | |- |
+ | | -111560919 | ||
+ | | 2010-11-29 0:00 | ||
+ | | SW | ||
+ | | No Violations | ||
+ | | 0.70 | ||
+ | |- | ||
+ | | -1255799910 | ||
+ | | 2003-10-9 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
+ | |- | ||
+ | | -1344501040 | ||
+ | | 2003-2-11 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
− | |||
|- | |- | ||
+ | | -1360095314 | ||
+ | | 2008-2-28 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
+ | | | ||
|- | |- | ||
− | | | + | | -1392129284 |
− | | 2007- | + | | 2007-5-31 0:00: |
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
− | | | + | |- |
+ | | -1403278144 | ||
+ | | 2019-9-26 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
+ | |- | ||
+ | | -1447025193 | ||
+ | | 2016-7-6 0:00:0 | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
− | |||
|- | |- | ||
+ | | -1455022409 | ||
+ | | 2003-3-13 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
+ | | | ||
|- | |- | ||
− | | | + | | -1604197124 |
− | | | + | | 2013-10-4 0:00: |
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
− | | | + | |- |
+ | | -1606053051 | ||
+ | | 2008-6-18 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
+ | |- | ||
+ | | -1616091438 | ||
+ | | 2008-8-28 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
− | |||
|- | |- | ||
+ | | -1757223329 | ||
+ | | 2013-8-20 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
+ | | 4.00 | ||
|- | |- | ||
− | | | + | | -1803067738 |
− | | | + | | 2015-11-17 0:00 |
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
− | | | + | |- |
+ | | -1888978830 | ||
+ | | 2012-4-12 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
+ | |- | ||
+ | | -1955540783 | ||
+ | | 2007-10-18 0:00 | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
+ | |- | ||
+ | | -1957627969 | ||
+ | | 2018-4-25 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
|- | |- | ||
+ | | -1968010362 | ||
+ | | 2017-6-12 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
+ | | | ||
|- | |- | ||
− | | | + | | -2013257317 |
− | | 2007- | + | | 2007-6-6 0:00:0 |
− | | | + | | SW |
− | | | + | | No Violations |
| | | | ||
+ | |- | ||
+ | | -2074430978 | ||
+ | | 2005-3-18 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
+ | |- | ||
+ | | -2084257862 | ||
+ | | 2010-3-9 0:00:0 | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
|- | |- | ||
+ | | -219340022 | ||
+ | | 2010-5-25 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
+ | | 1.50 | ||
|- | |- | ||
− | | | + | | -282651337 |
− | | | + | | 2017-5-2 0:00:0 |
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
− | | | + | |- |
+ | | -294549051 | ||
+ | | 2018-2-18 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
+ | |- | ||
+ | | -311803435 | ||
+ | | 2004-3-15 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
+ | |- | ||
+ | | -410693322 | ||
+ | | 2014-10-20 0:00 | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
|- | |- | ||
+ | | -431737975 | ||
+ | | 2006-8-1 0:00:0 | ||
+ | | SW | ||
+ | | No Violations | ||
+ | | | ||
|- | |- | ||
− | | | + | | -436577129 |
− | | | + | | 2019-2-11 0:00: |
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
− | | | + | |- |
+ | | -459187439 | ||
+ | | 2016-1-11 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
+ | |- | ||
+ | | -525219068 | ||
+ | | 2007-9-14 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
+ | |- | ||
+ | | -528727351 | ||
+ | | 2015-7-1 0:00:0 | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
|- | |- | ||
+ | | -557797191 | ||
+ | | 2017-12-14 0:00 | ||
+ | | SW | ||
+ | | No Violations | ||
+ | | | ||
|- | |- | ||
− | | | + | | -609666894 |
− | | | + | | 2018-7-10 0:00: |
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
− | | | + | |- |
+ | | -726365473 | ||
+ | | 2006-2-7 0:00:0 | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
+ | |- | ||
+ | | -783143412 | ||
+ | | 2011-3-8 0:00:0 | ||
+ | | SW | ||
+ | | No Violations | ||
+ | | 1.00 | ||
+ | |- | ||
+ | | -791972241 | ||
+ | | 2006-12-3 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
+ | |- | ||
+ | | -822754939 | ||
+ | | 2017-1-6 0:00:0 | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
|- | |- | ||
+ | | -864955083 | ||
+ | | 2012-1-31 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
+ | | 1.00 | ||
|- | |- | ||
− | | | + | | -872319558 |
− | | | + | | 2013-9-9 0:00:0 |
− | | | + | | SW |
− | | | + | | No Violations |
| | | | ||
+ | |- | ||
+ | | -928840493 | ||
+ | | 2010-8-30 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
+ | | 0.50 | ||
+ | |- | ||
+ | | -967336626 | ||
+ | | 2010-8-23 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
+ | | 0.70 | ||
+ | |- | ||
+ | | -999881571 | ||
+ | | 2005-8-15 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
+ | |- | ||
+ | | 0000UIC915 | ||
+ | | 1990-05-17 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | 1501:9-3-07 (J) OPERATION, MONITORIN | ||
+ | |- | ||
+ | | 0000UIC999 | ||
+ | | 1990-10-12 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | 1501:9-3-07 E MONTHLY VOLMES - TL | ||
+ | |- | ||
+ | | 000UIC1000 | ||
+ | | 1990-10-12 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | 1501:9-3-07 F MONITOR ANNULAR - TL | ||
+ | |- | ||
+ | | 000UIC1703 | ||
+ | | 1997-07-28 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | 1501: 9-1-07 PREVENT CONTAMINATE | ||
+ | |- | ||
+ | | 000UIC1798 | ||
+ | | 1999-09-17 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | 1501:9-3-04 (A) POLLUTION | ||
+ | |- | ||
+ | | 000UIC1799 | ||
+ | | 1999-09-17 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | 1501:9-9-05 (10) IDENTIFICATION | ||
+ | |- | ||
+ | | 000UIC1800 | ||
+ | | 1999-09-17 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | 1509.072 RESTORATION | ||
+ | |- | ||
+ | | 0111560919 | ||
+ | | 2010-11-29 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection this day found pump not running, well not in use. Well had no # on it. Tickets in pump house show last water brought in on 11/23/10. Dike area contains water but very little to no oil. Water tests fresh. | ||
+ | |- | ||
+ | | 0186316124 | ||
+ | | 2017-08-24 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Well not in operation at this time. | ||
+ | |- | ||
+ | | 0219340022 | ||
+ | | 2010-05-25 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection this day found pump not running, well tests #530 on tubing, 0 on annulus, good IDs at well and pump house, skim of oil on fresh water inside dike. | ||
+ | |- | ||
+ | | 0282651337 | ||
+ | | 2017-05-02 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspetion today indicated that injection pump was not in operation and it appears that wells are not being used much at this time. | ||
+ | |- | ||
+ | | 0291217080 | ||
+ | | 2007-12-10 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Quarterly inspection due this day - found well/pump not in operation - trucker was there to clean up the water in the dike area - was sucking it out and putting it back into tanks to be pumped down well. He said he wasnt to start up well. Well very far back in - too muddy to walk or drive to this day. Well was recently treated with acid and brought down to allowable pressure so should be still OK. | ||
+ | |- | ||
+ | | 0294549051 | ||
+ | | 2018-02-18 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Injection pump not in operation today. | ||
+ | |||
+ | |||
+ | Called company rep and requested that fresh water within dike area be removed and properly disposed of. | ||
+ | |- | ||
+ | | 0311803435 | ||
+ | | 2004-03-15 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Violations remedied | ||
+ | |- | ||
+ | | 0357816093 | ||
+ | | 2004-05-06 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection this day found no violations - pumping not running - pit area looking a little better - still needs some work but pit area dry, had been cleaning some | ||
+ | |- | ||
+ | | 0366523147 | ||
+ | | 2009-02-19 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Quarterly inspection due - well still not producing, have tubing pulled and need to find leak in casing. Service rig on location and are concentrating on getting 2nd well going for now. Have a lot of water they say, need to get rid off. Dike area full of water, assume its fresh. | ||
+ | |- | ||
+ | | 0410693322 | ||
+ | | 2014-10-20 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Facility is still down waiting on owner to spot oil tank at the facility before placing wells into operation. | ||
+ | |- | ||
+ | | 0431737975 | ||
+ | | 2006-08-01 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection this day found dike area containing a little oil, someone ran the tank over again, man there doing maintanence on the pump - changing filters, water truck there unloading. | ||
+ | |- | ||
+ | | 0436577129 | ||
+ | | 2019-02-11 | ||
+ | | Salt Water Injection Well | ||
+ | | Violations Noted | ||
+ | | The Division has not received the 4th quarter brine disposal fees for 2018. Please forward disposal fees and sheets to the Division by 3/12/2019. | ||
+ | |- | ||
+ | | 0444319928 | ||
+ | | 2012-03-05 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | My inspection this day is routine - This day found the area inside the dike full of fresh rain water. The plan was for Triad to operate the facility for Carper Well Service - I am waiting on Triad to submit plan to Columbus to make changes, replace the leaking liner, reset the tanks and resolve the citation. No changes yet, pump and wells still down. | ||
+ | |- | ||
+ | | 0459187439 | ||
+ | | 2016-01-11 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Injection pump not in operation during my inspection. | ||
+ | |- | ||
+ | | 0519100718 | ||
+ | | 2005-05-27 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection this day found unloading pad all cleaned off, someone had pumped oil/water out of pit area and attempting to clean up - not done yet and not good enough but will continue to monitor | ||
+ | |- | ||
+ | | 0519329515 | ||
+ | | 2014-01-15 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection revealed that owner has rebuilt dike area and they have new liner in place and it has been covered with sand and they are waiting on new storage tanks to be delivered and once in place they will replace injection lines from pumphouse to the wellhead. | ||
+ | Note: Previous notice of violation issuedon facility has been resolved. | ||
+ | |- | ||
+ | | 0525219068 | ||
+ | | 2007-09-14 | ||
+ | | Salt Water Injection Well | ||
+ | | Violations Noted | ||
+ | | Quarterly inspection due - today found dike area full of water and oil, pump was running, went back and checked well and it is over the permitted pressure - gauged at 620# and only 530# allowed. Called Tom Tomastik (no answer), Mike Kavage who advised to tell them to shut well down. Called Millard and told him to shut down, then Tom called back and said they didnt have to but had to have pressure down to continue to operator. According to secretary at Carper, had been down waiting on pump parts for several days - they had finally come and were now pumping to get caught up - this was not usual. Anyway, since they did not have to shut down, did not wait for Millard to come out - late Friday afternoon. Will recheck Monday to see progress. | ||
+ | |- | ||
+ | | 0528727351 | ||
+ | | 2015-07-01 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection revealed that injection pump was in operation during my inspection and we measured dike area and recorded total amount of tanks with in dike area. | ||
+ | 61x40x48 high with a calculated volume of 1733 bbl and there is 5-210 bbl placed within dike area. | ||
+ | |- | ||
+ | | 0557797191 | ||
+ | | 2017-12-14 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Well is not in operation at this time. | ||
+ | |- | ||
+ | | 0585139923 | ||
+ | | 2002-03-14 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
| | | | ||
|- | |- | ||
+ | | 0609666894 | ||
+ | | 2018-07-10 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection today revealed that injection pump was not in operation and I was on site to witness MIT testing of said well, they applied 600 psi of pressure and we monitored it for thirty minutes with no decline in pressure. | ||
+ | |- | ||
+ | | 0726365473 | ||
+ | | 2006-02-07 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Pump not running today, must be taking alittle water as flilter laying out to dry on pad. Looks pretty good today, dike area dry, not much oil around the area. | ||
+ | |- | ||
+ | | 0783143412 | ||
+ | | 2011-03-08 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection this day found pump not running, wells registering no pressure. Disposal not used much, good IDs, dike area has fresh water pumped out, still very oily. | ||
+ | |- | ||
+ | | 0791972241 | ||
+ | | 2006-12-03 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection this day found no pump in pumphouse. Either it went bad or needed service? Did not go back to well as too muddy to get to it. It has been tto muddy for a week so went ahead and did one. | ||
+ | |- | ||
+ | | 0822754939 | ||
+ | | 2017-01-06 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection today revealed that well is currently not in operation due to lack of brine hauling activity. | ||
+ | |- | ||
+ | | 0864955083 | ||
+ | | 2012-01-31 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | I met with John Jack and Dylan from Triad, as well as Jeff Jones from J & L Water Services, to discuss their plans for re-working the facility. Triad plans to clean out the storage tanks, then remove all equipment from inside the dike area, clean out and re-lay the plastic liner and cover it with gravel. They will then place the tanks back inside the dike, adding a 100 bbl tank for oil/condensate. They will rework the sump pump and collection hole to make it work, will move the pumphouse building off to the side and pour concrete, then replace the building back on top of the concrete. I told John he needed to put these plans in writing and submit to Tom Tomastik. J & L will be doing most of the construction and BBU will be cleaning the tanks. Triad is anxious to begin. | ||
+ | |- | ||
+ | | 0872319558 | ||
+ | | 2013-09-09 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Clean up continues within tank area. | ||
+ | |- | ||
+ | | 0889290563 | ||
+ | | 2018-12-06 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection revealed that injection pump was not in operation during my inspection. | ||
+ | |||
+ | |||
+ | Note: Well does not appear to be used much at this time. | ||
+ | |- | ||
+ | | 0928840493 | ||
+ | | 2010-08-30 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Dike area has had water removed from inside but still is oil inside dike. Called Ryan, he said they would come over and put fresh water in, float the oil up and suck it off. Has not been done yet. | ||
+ | |- | ||
+ | | 0967336626 | ||
+ | | 2010-08-23 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection this day found well not in operation, does not look like being used much. Dike surrounding storage tanks has water, think coating of oil in it - called operator and asked him to pump out. Test on well showed on pressure on annulus or tubing. | ||
+ | |- | ||
+ | | 0999710244 | ||
+ | | 2013-02-12 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection revealed that well is not in operation at this time, walked flow line to check for leaks none were found. | ||
+ | Note: Called company and requested that they have positive pressure applied to annulus of tubing and also remove fresh water build up in tank area. | ||
+ | |- | ||
+ | | 0999881571 | ||
+ | | 2005-08-15 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection this day found facility looking much better. Still little bits of oil around but that happens - this well gets more oil and junk than others. Dike area clean, dry, empty of fluids, pump not running - no pressure (30#) on well. | ||
|- | |- | ||
| 1005312311 | | 1005312311 | ||
| 2007-10-01 | | 2007-10-01 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Pump not running - cannot check pressure. | | Pump not running - cannot check pressure. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1005625518 | | 1005625518 | ||
| 2014-09-15 | | 2014-09-15 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection revealed that owner has nearly completed rework project at site and I informed him that flow line would need to be tested along with performing annulus test on tubing to ensure the division that they still have good casing integrity. | | Inspection revealed that owner has nearly completed rework project at site and I informed him that flow line would need to be tested along with performing annulus test on tubing to ensure the division that they still have good casing integrity. | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 1014406206 |
− | |||
| 2011-11-23 | | 2011-11-23 | ||
− | | | + | | Salt Water Injection Well |
− | | Inspection this day found facility still down. I found fresh water, about 1 | + | | No Violations |
− | + | | Inspection this day found facility still down. I found fresh water, about 1 deep, inside the facility. This is probably due to the hard rainfall from the last couple of days. The operator is trying to keep it pumped out. The brine kill area below dike still has not grown back completely. Water still appears to be running from inside dike area. Still will not resolve the Notice of Violation. Proper identification are posted. I did not go to the wells as they are still shut down. | |
− | |||
− | |||
|- | |- | ||
+ | | 1035794489 | ||
+ | | 2016-10-14 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Well not in operation at this time. | ||
|- | |- | ||
| 1039207994 | | 1039207994 | ||
| 2013-12-03 | | 2013-12-03 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Owner is presently placing sand on top of liner making preparation for spotting of new storage tanks when are delivered. | | Owner is presently placing sand on top of liner making preparation for spotting of new storage tanks when are delivered. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1045398657 | | 1045398657 | ||
| 2011-07-27 | | 2011-07-27 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection this day found bine kill area still has not been cleaned up - nothing growing, no sign of lime and grass seed. Told him he could not use well until kill area back to grass. Has been keeping dike area clear of fluids but still oily mess, oil coating on gravel. | | Inspection this day found bine kill area still has not been cleaned up - nothing growing, no sign of lime and grass seed. Told him he could not use well until kill area back to grass. Has been keeping dike area clear of fluids but still oily mess, oil coating on gravel. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1050681812 | | 1050681812 | ||
| 2003-04-18 | | 2003-04-18 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| (4)gather up old flow line | | (4)gather up old flow line | ||
(10)housekeeping needs done on unloadng pad area. | (10)housekeeping needs done on unloadng pad area. | ||
Line 197: | Line 802: | ||
Pressured tested flow line@700psi for 15min. | Pressured tested flow line@700psi for 15min. | ||
Suggest operator walk flow line daily to monitor for possible leaks/ | Suggest operator walk flow line daily to monitor for possible leaks/ | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1051385611 | | 1051385611 | ||
| 2003-04-18 | | 2003-04-18 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| (4)clean up needed in tank area | | (4)clean up needed in tank area | ||
(10)remove old flow line | (10)remove old flow line | ||
Line 211: | Line 813: | ||
suggest walking flow line daily to monitor for possible leaks | suggest walking flow line daily to monitor for possible leaks | ||
Well not in operation the day of my inspection,changing flowline. | Well not in operation the day of my inspection,changing flowline. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1061016400 | | 1061016400 | ||
| 2007-09-17 | | 2007-09-17 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection found pump running, did not go back in field to check pressure, work had been done on dike area and water/oil levels are lower than they were on Friday. Will give a week before rechecking pressures and dike area. Tom T. said they were allowed to continue pumping and had to get their pressure down. | | Inspection found pump running, did not go back in field to check pressure, work had been done on dike area and water/oil levels are lower than they were on Friday. Will give a week before rechecking pressures and dike area. Tom T. said they were allowed to continue pumping and had to get their pressure down. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1063032549 | | 1063032549 | ||
| 2003-09-08 | | 2003-09-08 | ||
− | | | + | | Salt Water Injection Well |
− | | | + | | No Violations |
− | + | | IDs good, dike good, pit area still very messy with oil, had called operator and he said would clean up, pump running, well head pressure 55# | |
− | |||
− | |||
− | |||
|- | |- | ||
| 1076508211 | | 1076508211 | ||
| 2004-02-11 | | 2004-02-11 | ||
− | | | + | | Salt Water Injection Well |
− | | Area looks better than it had but still fresh water and a little oil in pit at tanks - met Ryan Carper and he said | + | | No Violations |
− | + | | Area looks better than it had but still fresh water and a little oil in pit at tanks - met Ryan Carper and he said didnt want to put fresh water in lines and then have them freeze - so put in pit - had repaired hoses but still one leaking - he said woul | |
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 1082080785 |
| 2005-05-18 | | 2005-05-18 | ||
− | | | + | | Salt Water Injection Well |
− | | Well tested OK but pit/dike area big mess - full of oil and sludge. Called Carper and they say people who dump water | + | | Violations Noted |
− | + | | Well tested OK but pit/dike area big mess - full of oil and sludge. Called Carper and they say people who dump water dont look to see if tanks full before unloading. They just dump, running the tanks over and it runs in pit. Asked to get cleaned up. | |
− | |||
− | |||
− | |||
|- | |- | ||
| 1092078026 | | 1092078026 | ||
| 2004-08-09 | | 2004-08-09 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection this day found well, tanks and pit area looking about the same - messy. Well not in operation, 15# on tubing, 0# on annulus. Filter out and tore apart - well not pumped in awhile but Decker there dumping water | | Inspection this day found well, tanks and pit area looking about the same - messy. Well not in operation, 15# on tubing, 0# on annulus. Filter out and tore apart - well not pumped in awhile but Decker there dumping water | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1100796120 | | 1100796120 | ||
| 2004-11-17 | | 2004-11-17 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection this day found shut-off valve not holding - called and asked them to get new valve and gauge on well and will go back next week. | | Inspection this day found shut-off valve not holding - called and asked them to get new valve and gauge on well and will go back next week. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 1101186217 |
| 2002-03-14 | | 2002-03-14 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
| | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1102962763 | | 1102962763 | ||
| 2004-12-13 | | 2004-12-13 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection this day found no violations, pump not running, pit area around tanks empty. | | Inspection this day found no violations, pump not running, pit area around tanks empty. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1108597221 | | 1108597221 | ||
| 2009-05-27 | | 2009-05-27 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Well is still not in operation. Still need to find hole in casing. | | Well is still not in operation. Still need to find hole in casing. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1139630263 | | 1139630263 | ||
| 2005-11-21 | | 2005-11-21 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection this day found no violations, unit looking pretty good, pump not running | | Inspection this day found no violations, unit looking pretty good, pump not running | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1227277576 | | 1227277576 | ||
| 2008-11-20 | | 2008-11-20 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection this day found operator out at well, trying to get house gas back on for landowner. They are expecting a service rig in next day or so. This well still down, looking for hole in the casing but rig will go on new well - they believe they can run packer, tubing and start injecting as they found no new/additional perfs in this well (#7958). Repeated that I needed to be there when packer goes in. | | Inspection this day found operator out at well, trying to get house gas back on for landowner. They are expecting a service rig in next day or so. This well still down, looking for hole in the casing but rig will go on new well - they believe they can run packer, tubing and start injecting as they found no new/additional perfs in this well (#7958). Repeated that I needed to be there when packer goes in. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1237988515 | | 1237988515 | ||
| 2009-03-24 | | 2009-03-24 | ||
− | | | + | | Salt Water Injection Well |
− | | Inspection this day found service rig has moved back over well. Producing casing has hole, injection not possible as | + | | No Violations |
− | + | | Inspection this day found service rig has moved back over well. Producing casing has hole, injection not possible as cant hold pressure. Previously, packer and tubing had been pulled from well, plug set below the perfs and retainer had been set above, well reperfd above the cement. Retainer and plug provided the opportunity to circulate after casing perfd to prove well is circulating, zone can be squeezed. Well would not circulate so plans are to get a pump truck in, pressure up on the well to see if circulation can be realized, then cement backside of casing up past where hole is in 4.5 casing. If that doesnt work, will make into a producer in the Cow Run Sand. | |
− | |||
− | |||
− | |||
|- | |- | ||
| 1252591045 | | 1252591045 | ||
| 2009-09-07 | | 2009-09-07 | ||
− | | | + | | Salt Water Injection Well |
− | | Inspection this day - | + | | No Violations |
− | + | | Inspection this day --4 hook-wall packer going into hole - new rubber on it - and then tubing. Tubing/bottom of packer ran to 1779.7 Will pressure test tomorrow. | |
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 1255799910 |
| 2003-10-09 | | 2003-10-09 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection this day found well still very messy with oil and saltwater in pit. Hose connected to pump in pumphouse leaking saltwater. Also need fence or gate as horse prints around pit. Contacted Operator and gave verbal NOV requesting removal of all contaminated soil, check pit liner to make sure still good, repair leaking hose, and remove all water from pit. Gave operator 2 weeks | | Inspection this day found well still very messy with oil and saltwater in pit. Hose connected to pump in pumphouse leaking saltwater. Also need fence or gate as horse prints around pit. Contacted Operator and gave verbal NOV requesting removal of all contaminated soil, check pit liner to make sure still good, repair leaking hose, and remove all water from pit. Gave operator 2 weeks | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1304906615 | | 1304906615 | ||
| 2013-03-18 | | 2013-03-18 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection revealed that well was not in operation and owner still needs to have tanks removed and cleaned out and containment area fixed up and drains from pump house plumbed to vault area. | | Inspection revealed that well was not in operation and owner still needs to have tanks removed and cleaned out and containment area fixed up and drains from pump house plumbed to vault area. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1307377426 | | 1307377426 | ||
| 2011-06-02 | | 2011-06-02 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection found pit has been sucked out, still small amount of oil they need to get out. No lime spread yet and called Smitty and asked him to get it done soon. Said he would, he thought Millard had done it. | | Inspection found pit has been sucked out, still small amount of oil they need to get out. No lime spread yet and called Smitty and asked him to get it done soon. Said he would, he thought Millard had done it. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1310991737 | | 1310991737 | ||
| 2011-07-14 | | 2011-07-14 | ||
− | | | + | | Salt Water Injection Well |
− | | Met with Millard Carper - says he has put lime down, can he start using well again? I said to sow grass seed, give it alittle time to grow. Pump dike out and keep it dry. He seems to think dike was full, due to many rains, and simply ran over when got full to the top - | + | | No Violations |
− | + | | Met with Millard Carper - says he has put lime down, can he start using well again? I said to sow grass seed, give it alittle time to grow. Pump dike out and keep it dry. He seems to think dike was full, due to many rains, and simply ran over when got full to the top - shouldnt have been brine. I am willing to restart back up, when kill area is reclaimed, on the condition they keep water out of the dike area. Can start back up and test Millards theory before replacing all the liner. He says he also needs to clean out sump hole and that will help keep dike dry inside. | |
− | |||
− | |||
− | |||
|- | |- | ||
| 1317237266 | | 1317237266 | ||
| 2011-09-28 | | 2011-09-28 | ||
− | | | + | | Salt Water Injection Well |
− | | Inspection this day found pump not running, about 4 fresh water inside dike. Rained in last day so probably have not pumped it out yet - told them to keep it empty. Kill area below the dike starting to grow back but not satisfactory yet. Good | + | | No Violations |
− | + | | Inspection this day found pump not running, about 4 fresh water inside dike. Rained in last day so probably have not pumped it out yet - told them to keep it empty. Kill area below the dike starting to grow back but not satisfactory yet. Good IDs - still have to fix/repair plastic liner or prove it is not leaking. | |
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 1344501040 |
| 2003-02-11 | | 2003-02-11 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| (3) housekeeping unloading pad | | (3) housekeeping unloading pad | ||
(4)inside of dike area needs a good cleaning | (4)inside of dike area needs a good cleaning | ||
(11)house keeping in unloading pad area | (11)house keeping in unloading pad area | ||
No violations noted this inspection. | No violations noted this inspection. | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 1360095314 |
− | |||
| 2008-02-28 | | 2008-02-28 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection this day found quarterly requirement. Well not in production, pumphouse door shut with lock so believe not getting much water. Pump not running. Went back to well and gauges show both annulus and tubing on 0#. Water was in dike area at tank but was froze - this well difficult to get to, had to go when froze instead of waiting another couple weeks when road would be thawed out and muddy. | | Inspection this day found quarterly requirement. Well not in production, pumphouse door shut with lock so believe not getting much water. Pump not running. Went back to well and gauges show both annulus and tubing on 0#. Water was in dike area at tank but was froze - this well difficult to get to, had to go when froze instead of waiting another couple weeks when road would be thawed out and muddy. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1383591326 | | 1383591326 | ||
| 2013-11-04 | | 2013-11-04 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection on this day indicated that owner is presently installing new pit liner in tank area and placing sand on top of liner to help hold it in place. | | Inspection on this day indicated that owner is presently installing new pit liner in tank area and placing sand on top of liner to help hold it in place. | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 1392129284 |
− | |||
| 2007-05-31 | | 2007-05-31 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Called Carper and informed time for yearly pressure test - well down producing this day but did not do pressure test - will wait until next week for yearly. | | Called Carper and informed time for yearly pressure test - well down producing this day but did not do pressure test - will wait until next week for yearly. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1394934178 | | 1394934178 | ||
| 2009-09-08 | | 2009-09-08 | ||
− | | | + | | Salt Water Injection Well |
− | | | + | | No Violations |
− | + | -10# in 15 minute period. Passed test. Well tied into line, IDs back up and back taking water. I requested pit be emptied this day and filled in - cattle in the area and needed area cleaned up to avoid any livestock problems. Chief Orders resolved. | |
− | |||
− | |||
− | |||
|- | |- | ||
| 1403904313 | | 1403904313 | ||
| 2014-06-26 | | 2014-06-26 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection revealed that owner has removed old tanks from facility and they are waiting on new storage tanks to be delivered to site and placed in storage area. | | Inspection revealed that owner has removed old tanks from facility and they are waiting on new storage tanks to be delivered to site and placed in storage area. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1408315368 | | 1408315368 | ||
| 2014-08-13 | | 2014-08-13 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection revealed that owner has recently placed two 100 bbl. tanks at site and they plan on setting more storage tanks in the near future and also they plan on replacing flow line to both wells on the lease before placing them back into operation. | | Inspection revealed that owner has recently placed two 100 bbl. tanks at site and they plan on setting more storage tanks in the near future and also they plan on replacing flow line to both wells on the lease before placing them back into operation. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1411817526 | | 1411817526 | ||
| 2014-09-23 | | 2014-09-23 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| On site to hydro test new flow line and pressure test annulus of tubing company rep pumped fresh water through flow line and we tested it at 560 psi with no decline in pressure and then we moved on to performing annulus testing they placed 530 psi on annulus and we monitored pressure for 15 minutes with no decline in pressure. | | On site to hydro test new flow line and pressure test annulus of tubing company rep pumped fresh water through flow line and we tested it at 560 psi with no decline in pressure and then we moved on to performing annulus testing they placed 530 psi on annulus and we monitored pressure for 15 minutes with no decline in pressure. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1425331649 | | 1425331649 | ||
| 2015-03-02 | | 2015-03-02 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection revealed that well is not in operation at this time, owner has rebuilt facility and they are waiting on better weather so they can cover exposed portions of containment liner so it wont rot due to exposure to the sunlight. | | Inspection revealed that well is not in operation at this time, owner has rebuilt facility and they are waiting on better weather so they can cover exposed portions of containment liner so it wont rot due to exposure to the sunlight. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1427205444 | | 1427205444 | ||
| 2015-03-23 | | 2015-03-23 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection revealed that owner has completed remedial work required at site and is ready to place wells on the lease back into operation. | | Inspection revealed that owner has completed remedial work required at site and is ready to place wells on the lease back into operation. | ||
Note: Witnessed MIT testing on annulus of tubing today owner applied 550 psi and we monitored pressure for 15 minutes with no decline in pressure. | Note: Witnessed MIT testing on annulus of tubing today owner applied 550 psi and we monitored pressure for 15 minutes with no decline in pressure. | ||
− | Dike measurements are as follows | + | Dike measurements are as follows 25X50X48TALL with a calculated volume of 888 bbl. |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1433281537 | | 1433281537 | ||
| 2015-05-29 | | 2015-05-29 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| On site to witness MIT Testing of annulus of tubing and ensuring that they have good casing integrity company rep applied 585 psi of pressure and we monitored pressure for 15 minutes with no decline in pressures.(TEST PASSED) | | On site to witness MIT Testing of annulus of tubing and ensuring that they have good casing integrity company rep applied 585 psi of pressure and we monitored pressure for 15 minutes with no decline in pressures.(TEST PASSED) | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1436765132 | | 1436765132 | ||
| 2006-05-24 | | 2006-05-24 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection this day found well looking pretty good, no big messes, pump not running. | | Inspection this day found well looking pretty good, no big messes, pump not running. | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 1447025193 | ||
+ | | 2016-07-06 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection today revealed that well is not in operation at this time,owner is currently hauling water too there other facility in Noble county. | ||
|- | |- | ||
− | | | + | | 1455022409 |
| 2003-03-13 | | 2003-03-13 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| No violations noted | | No violations noted | ||
(3)tank area needs cleaned(remove oily soil in tank area+replace with stone to protect liner in dike area. | (3)tank area needs cleaned(remove oily soil in tank area+replace with stone to protect liner in dike area. | ||
If storing oil in tank beside of pump house tank will need tobeI.D.ed+diked | If storing oil in tank beside of pump house tank will need tobeI.D.ed+diked | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 1459624320 | ||
+ | | 2017-02-08 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection revealed that well is not in operation at this time but I had owner come out and perform mini pressure test on annulus of tubing to ensure the division of casing integrity. | ||
+ | |- | ||
+ | | 1482799903 | ||
+ | | 2016-09-06 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection today revealed that injection pump was not in operation and it was noted that injection line right away has been recently brush hogged and there was a worker on site weed eating around containment area during my inspection. | ||
|- | |- | ||
| 1484495878 | | 1484495878 | ||
| 2013-07-24 | | 2013-07-24 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Accompanied UIC III inspector Dave Ball on inspection of this well and tank battery. The tank battery has an excessive amount of fluid in it with oily fluid on top. | | Accompanied UIC III inspector Dave Ball on inspection of this well and tank battery. The tank battery has an excessive amount of fluid in it with oily fluid on top. | ||
+ | |- | ||
+ | | 1517664349 | ||
+ | | 2019-9-17 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
| 1538867436 | | 1538867436 | ||
| 2011-05-24 | | 2011-05-24 | ||
− | | | + | | Salt Water Injection Well |
− | | Inspection this day found pump not running. When looked over the facility, found brine kill area below and off to the side of the dike - looks like plastic liner has failed and brine has went beneath the dike brim, under the liner and killed vegetation in an area 100 | + | | Violations Noted |
− | + | | Inspection this day found pump not running. When looked over the facility, found brine kill area below and off to the side of the dike - looks like plastic liner has failed and brine has went beneath the dike brim, under the liner and killed vegetation in an area 100 x 25. Called operator and told him would need to shut down until issues are resolved - liner may have to be replaced and tanks removed from dike to do that. Have often found water inside the dike and tanks seem to overflow, thus the brine remains inside the dike and has travelled under the plastic. Carper in agreement, will start by liming the spot, then determine and fix leakage. 6/11/12 - Talked to Ryan Carper - he says lease is about to run out - | |
− | |||
− | |||
− | |||
|- | |- | ||
| 1577064649 | | 1577064649 | ||
| 2009-12-01 | | 2009-12-01 | ||
− | | | + | | Salt Water Injection Well |
− | | | + | | No Violations |
− | | | + | -- Checked pressures - pump not running has hasnt run for awhile. 0# on tubing, 0# on annulus - will have to check when pump running to verify there is difference. Inside dike area is completely dry - looks good! |
− | | | + | |- |
+ | | 1595438252 | ||
+ | | 2020-7-21 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
|- | |- | ||
− | | | + | | 1604197124 |
− | |||
| 2013-10-04 | | 2013-10-04 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Clean up continues at site owner has removed all storage tanks from dike area and is in process of removing all contaminated material from dike area and once all material is removed they will begin rebuilding facility. | | Clean up continues at site owner has removed all storage tanks from dike area and is in process of removing all contaminated material from dike area and once all material is removed they will begin rebuilding facility. | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 1606053051 |
− | |||
| 2008-06-18 | | 2008-06-18 | ||
− | | | + | | Salt Water Injection Well |
− | | Inspection this day for yearly pressure test. Well was shut off when we got there. Millard present to perform test, had to fill annulus with 32 gal water - when pressured up to 200#, did not hold and gradually fell to 0 over a period of 15-20 minutes. Millard was afraid it would not hold as had tested it early in the month and had taken it up to 400-500# which he realized later had hurt | + | | No Violations |
− | + | | Inspection this day for yearly pressure test. Well was shut off when we got there. Millard present to perform test, had to fill annulus with 32 gal water - when pressured up to 200#, did not hold and gradually fell to 0 over a period of 15-20 minutes. Millard was afraid it would not hold as had tested it early in the month and had taken it up to 400-500# which he realized later had hurt its integrety. Must have small hole in casing. Pressure test on tubing while pump running was 530# - this part passes and well is in no danger of contaminating ground water or other formations. Called Tom Tomastik to see what he wanted operator to do but I believe will have to fix casing. | |
− | |||
− | |||
|- | |- | ||
− | | | + | | 1616091438 |
− | |||
| 2008-08-28 | | 2008-08-28 | ||
− | | | + | | Salt Water Injection Well |
− | | Well still has | + | | No Violations |
− | + | | Well still has Chiefs Orders due to hole in casing. Millard says he is going to try to fix and then will continue to use. Still down this day. | |
− | |||
− | |||
− | |||
|- | |- | ||
| 1650540372 | | 1650540372 | ||
| 2003-11-04 | | 2003-11-04 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection this day found disposal site and location still not cleaned up. Called Operator and he was sending someone out today to get started on cleanup. Will recheck soon. | | Inspection this day found disposal site and location still not cleaned up. Called Operator and he was sending someone out today to get started on cleanup. Will recheck soon. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1684661490 | | 1684661490 | ||
| 2009-08-27 | | 2009-08-27 | ||
− | | | + | | Salt Water Injection Well |
− | | Service rig on location today, sending mandrel down to make sure casing is clear and clean before running packer on tubing. Millard Carper present and says well has been logged to find hole in casing, plug set below hole, casing | + | | No Violations |
− | + | | Service rig on location today, sending mandrel down to make sure casing is clear and clean before running packer on tubing. Millard Carper present and says well has been logged to find hole in casing, plug set below hole, casing perfd and squeezed to repaid/seal off hole, plug removed and well now ready to get back in operation. Plans are to run rebuilt packer next week and will call me before doing so. | |
− | |||
− | |||
− | |||
|- | |- | ||
| 1692665486 | | 1692665486 | ||
| 2014-05-12 | | 2014-05-12 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection revealed that owner has two more old tanks to be removed from site before they can start setting new storage tanks in dike area and it was discussed that they will replace flow line going to well head before placing well into operation. | | Inspection revealed that owner has two more old tanks to be removed from site before they can start setting new storage tanks in dike area and it was discussed that they will replace flow line going to well head before placing well into operation. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1743901733 | | 1743901733 | ||
| 2003-09-02 | | 2003-09-02 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| No violations noted this inspection,facility appears to be in good repair. | | No violations noted this inspection,facility appears to be in good repair. | ||
(3)clean up in tank area needed. | (3)clean up in tank area needed. | ||
(11)housekeeping in unloading area needed | (11)housekeeping in unloading area needed | ||
Note:Walked flowline | Note:Walked flowline | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1747602971 | | 1747602971 | ||
| 2008-06-03 | | 2008-06-03 | ||
− | | | + | | Salt Water Injection Well |
− | | Inspection for quarter - time for yearly pressure test and have scheduled | + | | No Violations |
− | + | | Inspection for quarter - time for yearly pressure test and have scheduled 2Xs and had to cancel. Will get done in next week or so. Today well not running, pit/dike area fairly dry - better than some other visits. | |
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 1757223329 |
| 2013-08-20 | | 2013-08-20 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| On site to witness clean up efforts being made at site, owner is removing material from tank area and hauling it to a approved landfill and once all solids and liquids are removed they will remove tanks and then start rebuilding process of entire storage facility. | | On site to witness clean up efforts being made at site, owner is removing material from tank area and hauling it to a approved landfill and once all solids and liquids are removed they will remove tanks and then start rebuilding process of entire storage facility. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1772252492 | | 1772252492 | ||
| 2014-03-10 | | 2014-03-10 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection revealed that well is down waiting on owner to complete rebuilding of storage tank facility. | | Inspection revealed that well is down waiting on owner to complete rebuilding of storage tank facility. | ||
+ | |- | ||
+ | | 1803067738 | ||
+ | | 2015-11-17 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection revealed that injection pump was not in operation today. | ||
+ | |- | ||
+ | | 186316124 | ||
+ | | 2017-8-24 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 1888978830 |
| 2012-04-12 | | 2012-04-12 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection revealed that injection pump was not in operation today and it appears that well has been out of service for quite some time, it has been noted that Green Hunter is working on service agreement with Carper to operate well and clean up existing issues at facility. | | Inspection revealed that injection pump was not in operation today and it appears that well has been out of service for quite some time, it has been noted that Green Hunter is working on service agreement with Carper to operate well and clean up existing issues at facility. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 1955540783 |
| 2007-10-18 | | 2007-10-18 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection this day was to meet with Dean Decker - can turn pump on so I can check pressures. He said Carper has had well acidized with 1200 gal. Of 15% - when I checked pressure it was at 530# which is the maximum limit. Carper has also cleaned out storage tanks, dike area is dry but still black from the water running over the tanks and coloring the gravel. Dean thinks it is more black water than oil. Will go ahead and clear NOV with the understanding that they must keep the dike area dry and continue to try and clean it up more. Pressure is passable. | | Inspection this day was to meet with Dean Decker - can turn pump on so I can check pressures. He said Carper has had well acidized with 1200 gal. Of 15% - when I checked pressure it was at 530# which is the maximum limit. Carper has also cleaned out storage tanks, dike area is dry but still black from the water running over the tanks and coloring the gravel. Dean thinks it is more black water than oil. Will go ahead and clear NOV with the understanding that they must keep the dike area dry and continue to try and clean it up more. Pressure is passable. | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 1957627969 | ||
+ | | 2018-04-25 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Inspection today revealed that injection pump was not in operation during my inspection. | ||
+ | |- | ||
+ | | 1968010362 | ||
+ | | 2017-06-12 | ||
+ | | Salt Water Injection Well | ||
+ | | No Violations | ||
+ | | Well not in operation at this time. | ||
|- | |- | ||
| 2004688845 | | 2004688845 | ||
| 2013-07-24 | | 2013-07-24 | ||
− | | | + | | Salt Water Injection Well |
+ | | Violations Noted | ||
| Inspection revealed that there was brine&oil within dike area and it appeared that someone had recently ran tanks over and owner has not complied with previous Compliance notice issued 5/24/11 for contamination at surface facility and dike not being liquid tight because it appears to be leaking because we ran Quantab test in water hole and they indicated that there was brine present outside of dike. | | Inspection revealed that there was brine&oil within dike area and it appeared that someone had recently ran tanks over and owner has not complied with previous Compliance notice issued 5/24/11 for contamination at surface facility and dike not being liquid tight because it appears to be leaking because we ran Quantab test in water hole and they indicated that there was brine present outside of dike. | ||
− | Note: | + | Note: Photos were taken and water samples were taken to Cambridge lab to be analyzed, |
Note: To properly fix dike owner will need to have tanks cleaned and removed from dike area and new liner installed after all contaminated material is removed from dike area and replaced with fresh soil and properly place identification at wellhead with complete information. | Note: To properly fix dike owner will need to have tanks cleaned and removed from dike area and new liner installed after all contaminated material is removed from dike area and replaced with fresh soil and properly place identification at wellhead with complete information. | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2013257317 |
− | |||
| 2007-06-06 | | 2007-06-06 | ||
− | | | + | | Salt Water Injection Well |
− | | Completed yearly injection pressure test this day. Pressured up annulus to 100# - pump was not working correctly and | + | | No Violations |
− | + | | Completed yearly injection pressure test this day. Pressured up annulus to 100# - pump was not working correctly and couldnt get any higher. Held 100# for 15 min - tubing tested at 318# - also held. Operator says he had pressured up annulus on Monday (this is Wednesday) and when we arrived, annulus was back to 0 already - this well never holds its annulus pressure, yet feel if there was a pipe or packer failure, we would see a rapid fall. I feel this pipe good but standard test requires 200# for 15 min. Pumphouse had been steam cleaned, looks good, fair amount of crusty, old oil in dike area but no water. Pump running this day | |
− | |||
− | |||
− | |||
|- | |- | ||
| 2021086250 | | 2021086250 | ||
| 2007-02-28 | | 2007-02-28 | ||
− | | | + | | Salt Water Injection Well |
+ | | No Violations | ||
| Inspection this day found dike area full of fresh water. Pump was running, would have liked to put my gauge on well, but valve to shut was not shutting. Contacted operator and asked to put a new gauge on - gauge read 700# and he was sure gauge was not reading correctly - and install a new valve so I could shut to put my own gauge on. No longer gauge in pumphouse - not required. Too muddy to back to well again today, or this week - will try to get a good test next week. Carper W. S. truck unloading water. | | Inspection this day found dike area full of fresh water. Pump was running, would have liked to put my gauge on well, but valve to shut was not shutting. Contacted operator and asked to put a new gauge on - gauge read 700# and he was sure gauge was not reading correctly - and install a new valve so I could shut to put my own gauge on. No longer gauge in pumphouse - not required. Too muddy to back to well again today, or this week - will try to get a good test next week. Carper W. S. truck unloading water. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2074430978 |
| 2005-03-18 | | 2005-03-18 | ||
− | | | + | | Salt Water Injection Well |
− | | Inspection this day found site still messy - never changes - hauler has spilled some oil on unloading pad and they have had broom out, trying to clean up. Fresh water in dike area but no oil this time. Injection well looks OK, up to 350# and pump not running. Good | + | | No Violations |
− | + | | Inspection this day found site still messy - never changes - hauler has spilled some oil on unloading pad and they have had broom out, trying to clean up. Fresh water in dike area but no oil this time. Injection well looks OK, up to 350# and pump not running. Good IDs, new needle valve on well. | |
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2084257862 |
| 2010-03-09 | | 2010-03-09 | ||
− | | | + | | Salt Water Injection Well |
− | | Inspection this day found pump running, well tested 370# on tubing, 0# on annulus. Very muddy, had to walk in to wells. Small amt fluid in dike area, good | + | | No Violations |
− | + | | Inspection this day found pump running, well tested 370# on tubing, 0# on annulus. Very muddy, had to walk in to wells. Small amt fluid in dike area, good IDs at well and at house. | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 291217080 | | 291217080 | ||
− | | 2007-12-10 | + | | 2007-12-10 0:00 |
− | | | + | | SW |
− | | | + | | No Violations |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| | | | ||
− | |||
|- | |- | ||
| 357816093 | | 357816093 | ||
− | | 2004- | + | | 2004-5-6 0:00:0 |
− | + | | SW | |
− | + | | No Violations | |
− | | | ||
− | | | ||
| | | | ||
− | |||
|- | |- | ||
| 366523147 | | 366523147 | ||
− | | 2009- | + | | 2009-2-19 0:00: |
− | | | + | | SW |
− | | | + | | No Violations |
− | |||
− | |||
| | | | ||
|- | |- | ||
+ | | 444319928 | ||
+ | | 2012-3-5 0:00:0 | ||
+ | | SW | ||
+ | | No Violations | ||
+ | | 0.70 | ||
|- | |- | ||
− | | | + | | 519100718 |
− | | | + | | 2005-5-27 0:00: |
− | | | + | | SW |
− | | | + | | No Violations |
| | | | ||
+ | |- | ||
+ | | 519329515 | ||
+ | | 2014-1-15 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
+ | |- | ||
+ | | 585139923 | ||
+ | | 2002-3-14 0:00: | ||
+ | | SW | ||
+ | | No Violations | ||
| | | | ||
|- | |- | ||
− | | | + | | 889290563 |
− | | - | + | | 2018-12-6 0:00: |
− | + | | SW | |
− | + | | No Violations | |
− | |||
− | | | ||
− | | | ||
| | | | ||
|- | |- | ||
− | | | + | | 999710244 |
− | | | + | | 2013-2-12 0:00: |
− | + | | SW | |
− | | | + | | No Violations |
− | | | ||
− | |||
− | |||
| | | | ||
|- | |- | ||
− | | | + | | UIC1000 |
− | + | | 1990-10-12 0:00 | |
− | | | + | | SW |
− | + | | No Violations | |
− | |||
− | | | ||
− | | | ||
| | | | ||
|- | |- | ||
− | | | + | | UIC1703 |
− | | | + | | 1997-7-28 0:00: |
− | + | | SW | |
− | + | | No Violations | |
− | |||
− | |||
− | | | ||
− | | | ||
| | | | ||
|- | |- | ||
− | | | + | | UIC1798 |
− | + | | 1999-9-17 0:00: | |
− | | | + | | SW |
− | + | | No Violations | |
− | |||
− | | | ||
− | | | ||
| | | | ||
|- | |- | ||
− | | | + | | UIC1799 |
− | + | | 1999-9-17 0:00: | |
− | | | + | | SW |
− | + | | No Violations | |
− | |||
− | | | ||
− | | | ||
| | | | ||
|- | |- | ||
− | | | + | | UIC1800 |
− | + | | 1999-9-17 0:00: | |
− | | | + | | SW |
− | + | | No Violations | |
− | |||
− | | | ||
− | | | ||
| | | | ||
|- | |- | ||
− | | | + | | UIC915 |
− | + | | 1990-5-17 0:00: | |
− | | | + | | SW |
− | + | | No Violations | |
− | |||
− | | | ||
− | | | ||
| | | | ||
|- | |- | ||
− | | | + | | UIC999 |
− | | - | + | | 1990-10-12 0:00 |
− | + | | SW | |
− | + | | No Violations | |
− | |||
− | | | ||
− | | | ||
| | | | ||
|- | |- | ||
+ | |} | ||
+ | ==== Violations Commited ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" style="text-align: center"| Inspection ID | ||
+ | !scope="col" style="text-align: center"| Violation ID | ||
+ | !scope="col" style="text-align: center"| Violation Date | ||
+ | !scope="col" style="text-align: center"| Violation Code | ||
+ | !scope="col" style="text-align: center"| Violation Comments | ||
|- | |- | ||
− | | | + | | 0436577129 |
− | | | + | | US-OH-124556 |
− | + | | 2019-04-08 | |
− | | | ||
− | |||
− | |||
| | | | ||
+ | | Failure to report disposal fees | ||
|- | |- | ||
− | | | + | | 0525219068 |
− | | - | + | | US-OH-125736 |
− | | | + | | 2007-09-18 |
− | |||
− | |||
− | |||
| | | | ||
− | | | + | | Pollution/Contamination |
− | |||
|- | |- | ||
− | | | + | | 0525219068 |
− | | | + | | US-OH-125737 |
− | + | | 2007-09-18 | |
− | |||
− | |||
− | | | ||
| | | | ||
+ | | Exceeding maximum allowable injection pressure | ||
|- | |- | ||
− | | | + | | 0525219068 |
− | | - | + | | US-OH-125738 |
− | | | + | | 2007-09-18 |
− | |||
− | |||
− | |||
− | |||
| | | | ||
+ | | Failure to monitor pressures/volumes | ||
|- | |- | ||
− | | | + | | 0525219068 |
− | | | + | | US-OH-125739 |
− | | | + | | 2007-09-18 |
− | |||
− | |||
− | |||
− | |||
− | |||
| | | | ||
+ | | Failure to monitor annulus pressure | ||
|- | |- | ||
− | | | + | | 1082080785 |
− | | - | + | | US-OH-101858 |
− | | 2005- | + | | 2005-05-19 |
− | |||
− | |||
− | |||
− | |||
| | | | ||
+ | | Contamination at surface facility (permit after 6-1-82) | ||
|- | |- | ||
− | | | + | | 1538867436 |
− | | | + | | US-OH-114860 |
− | + | | 2014-04-23 | |
− | |||
− | | | ||
− | |||
− | |||
| | | | ||
+ | | Contamination at surface facility (permit before 6-1-82) | ||
|- | |- | ||
− | | | + | | 1538867436 |
− | | | + | | US-OH-114861 |
− | + | | 2014-04-23 | |
− | | | ||
− | |||
− | |||
− | |||
| | | | ||
+ | | Pits not liquid tight/Improper construction or use | ||
|- | |- | ||
− | | | + | | 2004688845 |
− | + | | US-OH-120340 | |
− | | | + | | 2014-04-10 |
− | |||
− | | | ||
− | |||
− | |||
| | | | ||
+ | | Pollution/Contamination | ||
|- | |- | ||
− | | | + | | 2004688845 |
− | | | + | | US-OH-120341 |
− | + | | 2014-04-10 | |
− | | | ||
− | |||
− | |||
− | |||
| | | | ||
+ | | Contamination at surface facility (permit after 6-1-82) | ||
|- | |- | ||
− | | | + | | 2004688845 |
− | | | + | | US-OH-120342 |
− | | | + | | 2014-04-10 |
− | |||
− | |||
− | |||
− | |||
| | | | ||
+ | | Permit not displayed | ||
|- | |- | ||
− | | | + | | 2004688845 |
− | | | + | | US-OH-120343 |
− | + | | 2014-04-10 | |
− | | | ||
− | |||
− | |||
− | |||
| | | | ||
+ | | Pits not liquid tight/Improper construction or use | ||
|- | |- | ||
− | | | + | | 2004688845 |
− | + | | US-OH-120344 | |
− | | | + | | 2014-04-10 |
− | |||
− | | | ||
− | |||
− | |||
| | | | ||
+ | | Failure to repair pits/Unlawful use of pits | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = | + | | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables |
− | | publisher = [ | + | |publisher = [[Ohio Department of Natural Resources]] |
− | | date = | + | | date = 2020-11-16 |
− | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2020-11-16 }}</ref> |
− | == References == | + | ==References== |
− | + | <references/> | |
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
− | [[Category:Wells]] | + | [[Category:Ohio Wells]] |
Well ID: 34-167-27401 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.41,"lon":-81.65,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Washington | |
Municipality: Barlow Township | |
Operator Name: CARPER WELL SERVICE INC. | |
Well Pad ID: | |
Farm/Lease Name: DAVIS-HUFFMAN | |
License Status: Active Injection | |
License Date: 1989-05-03 | |
Spud Date: 1983-01-07 | |
Spud Drilling Contractor: SWANK-ULLMAN | |
Final Drill Date: 1983-01-10 | |
Well Total Depth: 1911.00 ft | |
Configuration: Vertical | |
Latitude: 39.410000 | |
Longitude: -81.650000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1982-12-30 | 118 BIG INJUN OIL & GAS INC GeoDate 12/30/82 |
Oil and Gas | 1982-12-30 | Issued Date 12/30/82 Expired Date 6/28/83 Acres 0020000 Tool Type RTA Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000 |
Original Spud | 1983-01-07 | CONVERT 12-15-84 |
Completed | 1983-01-10 | CONVERT 12-15-84 |
Reached Total Depth | 1983-01-10 | CONVERT 12-15-84 |
CO | 1984-12-13 | 642 LOTHES OIL & GAS INC GeoDate 12/13/84 |
Salt Water Injection Well | 1984-12-13 | Issued Date 12/13/84 Expired Date 6/11/85 Acres 0020000 Tool Type RTA Proposed Formation BEREA Proposed Depth 01911 Proposed Drill Depth 01911 |
Storage Well | 1984-12-13 | Issued Date 12/13/84 Expired Date 6/11/85 Acres 0020000 Tool Type RTA Proposed Formation BEREA Proposed Depth 01911 Proposed Drill Depth 01911 |
Completion Report Received | 1986-02-13 | CONVERT 12-15-84 |
CO | 1989-05-03 | 3133 PETROEL GeoDate 5/3/89 |
Conversion to Injector | 1989-05-03 | |
Unknown | 1989-05-03 | Issued Date 5/3/89 Expired Date 5/3/90 Proposed Purpose SW Was Plug Supervised Who Superivsed Plug and Abandon Date |
Construction Permit Expires | 1990-05-03 | CONVERT 12-15-84 |
First Injection | 1990-08-29 | CONVERT 12-15-84 |
Change of Owner | 1998-06-15 | Operator changed from 3133, PETROEL to 6158, JONES PERLEY E |
Change of Owner | 1999-02-03 | Operator changed from 6158, JONES PERLEY E to 3133, PETROEL |
Annulus Pressure Monitoring Approved | 1999-06-10 | CONVERT 12-15-84 |
Change of Owner | 2001-06-25 | Operator changed from 3133, PETROEL to 7007, CARPER WELL SERVICE |
Last Compliance Report | 2015-06-11 | CONVERT 12-15-84 |
Record Last Modified | 2017-10-19 | CONVERT 12-15-84 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2000-05-09 | 1811 | 1816 | 4 |
1811 | 1816 | 4 | |
1811 | 1816 | 4 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
CO2 | 0 | 350 Bbl | 10000 | FRAC: 350 LBS OF LIQUID CO2, 150 GAL OF 15% ACID, AND 10,000 LBS OF SAND | ||
ACID | 15 | 150 Gal | 0 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1014406206 | 2011-11-23 0:00 | SW | No Violations | 1.00 |
-1082080785 | 2005-5-18 0:00: | SW | No Violations | |
-1101186217 | 2002-3-14 0:00: | SW | No Violations | |
-111560919 | 2010-11-29 0:00 | SW | No Violations | 0.70 |
-1255799910 | 2003-10-9 0:00: | SW | No Violations | |
-1344501040 | 2003-2-11 0:00: | SW | No Violations | |
-1360095314 | 2008-2-28 0:00: | SW | No Violations | |
-1392129284 | 2007-5-31 0:00: | SW | No Violations | |
-1403278144 | 2019-9-26 0:00: | SW | No Violations | |
-1447025193 | 2016-7-6 0:00:0 | SW | No Violations | |
-1455022409 | 2003-3-13 0:00: | SW | No Violations | |
-1604197124 | 2013-10-4 0:00: | SW | No Violations | |
-1606053051 | 2008-6-18 0:00: | SW | No Violations | |
-1616091438 | 2008-8-28 0:00: | SW | No Violations | |
-1757223329 | 2013-8-20 0:00: | SW | No Violations | 4.00 |
-1803067738 | 2015-11-17 0:00 | SW | No Violations | |
-1888978830 | 2012-4-12 0:00: | SW | No Violations | |
-1955540783 | 2007-10-18 0:00 | SW | No Violations | |
-1957627969 | 2018-4-25 0:00: | SW | No Violations | |
-1968010362 | 2017-6-12 0:00: | SW | No Violations | |
-2013257317 | 2007-6-6 0:00:0 | SW | No Violations | |
-2074430978 | 2005-3-18 0:00: | SW | No Violations | |
-2084257862 | 2010-3-9 0:00:0 | SW | No Violations | |
-219340022 | 2010-5-25 0:00: | SW | No Violations | 1.50 |
-282651337 | 2017-5-2 0:00:0 | SW | No Violations | |
-294549051 | 2018-2-18 0:00: | SW | No Violations | |
-311803435 | 2004-3-15 0:00: | SW | No Violations | |
-410693322 | 2014-10-20 0:00 | SW | No Violations | |
-431737975 | 2006-8-1 0:00:0 | SW | No Violations | |
-436577129 | 2019-2-11 0:00: | SW | No Violations | |
-459187439 | 2016-1-11 0:00: | SW | No Violations | |
-525219068 | 2007-9-14 0:00: | SW | No Violations | |
-528727351 | 2015-7-1 0:00:0 | SW | No Violations | |
-557797191 | 2017-12-14 0:00 | SW | No Violations | |
-609666894 | 2018-7-10 0:00: | SW | No Violations | |
-726365473 | 2006-2-7 0:00:0 | SW | No Violations | |
-783143412 | 2011-3-8 0:00:0 | SW | No Violations | 1.00 |
-791972241 | 2006-12-3 0:00: | SW | No Violations | |
-822754939 | 2017-1-6 0:00:0 | SW | No Violations | |
-864955083 | 2012-1-31 0:00: | SW | No Violations | 1.00 |
-872319558 | 2013-9-9 0:00:0 | SW | No Violations | |
-928840493 | 2010-8-30 0:00: | SW | No Violations | 0.50 |
-967336626 | 2010-8-23 0:00: | SW | No Violations | 0.70 |
-999881571 | 2005-8-15 0:00: | SW | No Violations | |
0000UIC915 | 1990-05-17 | Salt Water Injection Well | No Violations | 1501:9-3-07 (J) OPERATION, MONITORIN |
0000UIC999 | 1990-10-12 | Salt Water Injection Well | No Violations | 1501:9-3-07 E MONTHLY VOLMES - TL |
000UIC1000 | 1990-10-12 | Salt Water Injection Well | No Violations | 1501:9-3-07 F MONITOR ANNULAR - TL |
000UIC1703 | 1997-07-28 | Salt Water Injection Well | No Violations | 1501: 9-1-07 PREVENT CONTAMINATE |
000UIC1798 | 1999-09-17 | Salt Water Injection Well | No Violations | 1501:9-3-04 (A) POLLUTION |
000UIC1799 | 1999-09-17 | Salt Water Injection Well | No Violations | 1501:9-9-05 (10) IDENTIFICATION |
000UIC1800 | 1999-09-17 | Salt Water Injection Well | No Violations | 1509.072 RESTORATION |
0111560919 | 2010-11-29 | Salt Water Injection Well | No Violations | Inspection this day found pump not running, well not in use. Well had no # on it. Tickets in pump house show last water brought in on 11/23/10. Dike area contains water but very little to no oil. Water tests fresh. |
0186316124 | 2017-08-24 | Salt Water Injection Well | No Violations | Well not in operation at this time. |
0219340022 | 2010-05-25 | Salt Water Injection Well | No Violations | Inspection this day found pump not running, well tests #530 on tubing, 0 on annulus, good IDs at well and pump house, skim of oil on fresh water inside dike. |
0282651337 | 2017-05-02 | Salt Water Injection Well | No Violations | Inspetion today indicated that injection pump was not in operation and it appears that wells are not being used much at this time. |
0291217080 | 2007-12-10 | Salt Water Injection Well | No Violations | Quarterly inspection due this day - found well/pump not in operation - trucker was there to clean up the water in the dike area - was sucking it out and putting it back into tanks to be pumped down well. He said he wasnt to start up well. Well very far back in - too muddy to walk or drive to this day. Well was recently treated with acid and brought down to allowable pressure so should be still OK. |
0294549051 | 2018-02-18 | Salt Water Injection Well | No Violations | Injection pump not in operation today.
|
0311803435 | 2004-03-15 | Salt Water Injection Well | No Violations | Violations remedied |
0357816093 | 2004-05-06 | Salt Water Injection Well | No Violations | Inspection this day found no violations - pumping not running - pit area looking a little better - still needs some work but pit area dry, had been cleaning some |
0366523147 | 2009-02-19 | Salt Water Injection Well | No Violations | Quarterly inspection due - well still not producing, have tubing pulled and need to find leak in casing. Service rig on location and are concentrating on getting 2nd well going for now. Have a lot of water they say, need to get rid off. Dike area full of water, assume its fresh. |
0410693322 | 2014-10-20 | Salt Water Injection Well | No Violations | Facility is still down waiting on owner to spot oil tank at the facility before placing wells into operation. |
0431737975 | 2006-08-01 | Salt Water Injection Well | No Violations | Inspection this day found dike area containing a little oil, someone ran the tank over again, man there doing maintanence on the pump - changing filters, water truck there unloading. |
0436577129 | 2019-02-11 | Salt Water Injection Well | Violations Noted | The Division has not received the 4th quarter brine disposal fees for 2018. Please forward disposal fees and sheets to the Division by 3/12/2019. |
0444319928 | 2012-03-05 | Salt Water Injection Well | No Violations | My inspection this day is routine - This day found the area inside the dike full of fresh rain water. The plan was for Triad to operate the facility for Carper Well Service - I am waiting on Triad to submit plan to Columbus to make changes, replace the leaking liner, reset the tanks and resolve the citation. No changes yet, pump and wells still down. |
0459187439 | 2016-01-11 | Salt Water Injection Well | No Violations | Injection pump not in operation during my inspection. |
0519100718 | 2005-05-27 | Salt Water Injection Well | No Violations | Inspection this day found unloading pad all cleaned off, someone had pumped oil/water out of pit area and attempting to clean up - not done yet and not good enough but will continue to monitor |
0519329515 | 2014-01-15 | Salt Water Injection Well | No Violations | Inspection revealed that owner has rebuilt dike area and they have new liner in place and it has been covered with sand and they are waiting on new storage tanks to be delivered and once in place they will replace injection lines from pumphouse to the wellhead.
Note: Previous notice of violation issuedon facility has been resolved. |
0525219068 | 2007-09-14 | Salt Water Injection Well | Violations Noted | Quarterly inspection due - today found dike area full of water and oil, pump was running, went back and checked well and it is over the permitted pressure - gauged at 620# and only 530# allowed. Called Tom Tomastik (no answer), Mike Kavage who advised to tell them to shut well down. Called Millard and told him to shut down, then Tom called back and said they didnt have to but had to have pressure down to continue to operator. According to secretary at Carper, had been down waiting on pump parts for several days - they had finally come and were now pumping to get caught up - this was not usual. Anyway, since they did not have to shut down, did not wait for Millard to come out - late Friday afternoon. Will recheck Monday to see progress. |
0528727351 | 2015-07-01 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection and we measured dike area and recorded total amount of tanks with in dike area.
61x40x48 high with a calculated volume of 1733 bbl and there is 5-210 bbl placed within dike area. |
0557797191 | 2017-12-14 | Salt Water Injection Well | No Violations | Well is not in operation at this time. |
0585139923 | 2002-03-14 | Salt Water Injection Well | No Violations | |
0609666894 | 2018-07-10 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was not in operation and I was on site to witness MIT testing of said well, they applied 600 psi of pressure and we monitored it for thirty minutes with no decline in pressure. |
0726365473 | 2006-02-07 | Salt Water Injection Well | No Violations | Pump not running today, must be taking alittle water as flilter laying out to dry on pad. Looks pretty good today, dike area dry, not much oil around the area. |
0783143412 | 2011-03-08 | Salt Water Injection Well | No Violations | Inspection this day found pump not running, wells registering no pressure. Disposal not used much, good IDs, dike area has fresh water pumped out, still very oily. |
0791972241 | 2006-12-03 | Salt Water Injection Well | No Violations | Inspection this day found no pump in pumphouse. Either it went bad or needed service? Did not go back to well as too muddy to get to it. It has been tto muddy for a week so went ahead and did one. |
0822754939 | 2017-01-06 | Salt Water Injection Well | No Violations | Inspection today revealed that well is currently not in operation due to lack of brine hauling activity. |
0864955083 | 2012-01-31 | Salt Water Injection Well | No Violations | I met with John Jack and Dylan from Triad, as well as Jeff Jones from J & L Water Services, to discuss their plans for re-working the facility. Triad plans to clean out the storage tanks, then remove all equipment from inside the dike area, clean out and re-lay the plastic liner and cover it with gravel. They will then place the tanks back inside the dike, adding a 100 bbl tank for oil/condensate. They will rework the sump pump and collection hole to make it work, will move the pumphouse building off to the side and pour concrete, then replace the building back on top of the concrete. I told John he needed to put these plans in writing and submit to Tom Tomastik. J & L will be doing most of the construction and BBU will be cleaning the tanks. Triad is anxious to begin. |
0872319558 | 2013-09-09 | Salt Water Injection Well | No Violations | Clean up continues within tank area. |
0889290563 | 2018-12-06 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection.
|
0928840493 | 2010-08-30 | Salt Water Injection Well | No Violations | Dike area has had water removed from inside but still is oil inside dike. Called Ryan, he said they would come over and put fresh water in, float the oil up and suck it off. Has not been done yet. |
0967336626 | 2010-08-23 | Salt Water Injection Well | No Violations | Inspection this day found well not in operation, does not look like being used much. Dike surrounding storage tanks has water, think coating of oil in it - called operator and asked him to pump out. Test on well showed on pressure on annulus or tubing. |
0999710244 | 2013-02-12 | Salt Water Injection Well | No Violations | Inspection revealed that well is not in operation at this time, walked flow line to check for leaks none were found.
Note: Called company and requested that they have positive pressure applied to annulus of tubing and also remove fresh water build up in tank area. |
0999881571 | 2005-08-15 | Salt Water Injection Well | No Violations | Inspection this day found facility looking much better. Still little bits of oil around but that happens - this well gets more oil and junk than others. Dike area clean, dry, empty of fluids, pump not running - no pressure (30#) on well. |
1005312311 | 2007-10-01 | Salt Water Injection Well | No Violations | Pump not running - cannot check pressure. |
1005625518 | 2014-09-15 | Salt Water Injection Well | No Violations | Inspection revealed that owner has nearly completed rework project at site and I informed him that flow line would need to be tested along with performing annulus test on tubing to ensure the division that they still have good casing integrity. |
1014406206 | 2011-11-23 | Salt Water Injection Well | No Violations | Inspection this day found facility still down. I found fresh water, about 1 deep, inside the facility. This is probably due to the hard rainfall from the last couple of days. The operator is trying to keep it pumped out. The brine kill area below dike still has not grown back completely. Water still appears to be running from inside dike area. Still will not resolve the Notice of Violation. Proper identification are posted. I did not go to the wells as they are still shut down. |
1035794489 | 2016-10-14 | Salt Water Injection Well | No Violations | Well not in operation at this time. |
1039207994 | 2013-12-03 | Salt Water Injection Well | No Violations | Owner is presently placing sand on top of liner making preparation for spotting of new storage tanks when are delivered. |
1045398657 | 2011-07-27 | Salt Water Injection Well | No Violations | Inspection this day found bine kill area still has not been cleaned up - nothing growing, no sign of lime and grass seed. Told him he could not use well until kill area back to grass. Has been keeping dike area clear of fluids but still oily mess, oil coating on gravel. |
1050681812 | 2003-04-18 | Salt Water Injection Well | No Violations | (4)gather up old flow line
(10)housekeeping needs done on unloadng pad area. (11)clean up needed in tank area seed and mulch needed on kill area Pressured tested flow line@700psi for 15min. Suggest operator walk flow line daily to monitor for possible leaks/ |
1051385611 | 2003-04-18 | Salt Water Injection Well | No Violations | (4)clean up needed in tank area
(10)remove old flow line (11)housekeeping needed done in unloading area seed+mulch needed on kill area suggest walking flow line daily to monitor for possible leaks Well not in operation the day of my inspection,changing flowline. |
1061016400 | 2007-09-17 | Salt Water Injection Well | No Violations | Inspection found pump running, did not go back in field to check pressure, work had been done on dike area and water/oil levels are lower than they were on Friday. Will give a week before rechecking pressures and dike area. Tom T. said they were allowed to continue pumping and had to get their pressure down. |
1063032549 | 2003-09-08 | Salt Water Injection Well | No Violations | IDs good, dike good, pit area still very messy with oil, had called operator and he said would clean up, pump running, well head pressure 55# |
1076508211 | 2004-02-11 | Salt Water Injection Well | No Violations | Area looks better than it had but still fresh water and a little oil in pit at tanks - met Ryan Carper and he said didnt want to put fresh water in lines and then have them freeze - so put in pit - had repaired hoses but still one leaking - he said woul |
1082080785 | 2005-05-18 | Salt Water Injection Well | Violations Noted | Well tested OK but pit/dike area big mess - full of oil and sludge. Called Carper and they say people who dump water dont look to see if tanks full before unloading. They just dump, running the tanks over and it runs in pit. Asked to get cleaned up. |
1092078026 | 2004-08-09 | Salt Water Injection Well | No Violations | Inspection this day found well, tanks and pit area looking about the same - messy. Well not in operation, 15# on tubing, 0# on annulus. Filter out and tore apart - well not pumped in awhile but Decker there dumping water |
1100796120 | 2004-11-17 | Salt Water Injection Well | No Violations | Inspection this day found shut-off valve not holding - called and asked them to get new valve and gauge on well and will go back next week. |
1101186217 | 2002-03-14 | Salt Water Injection Well | No Violations | |
1102962763 | 2004-12-13 | Salt Water Injection Well | No Violations | Inspection this day found no violations, pump not running, pit area around tanks empty. |
1108597221 | 2009-05-27 | Salt Water Injection Well | No Violations | Well is still not in operation. Still need to find hole in casing. |
1139630263 | 2005-11-21 | Salt Water Injection Well | No Violations | Inspection this day found no violations, unit looking pretty good, pump not running |
1227277576 | 2008-11-20 | Salt Water Injection Well | No Violations | Inspection this day found operator out at well, trying to get house gas back on for landowner. They are expecting a service rig in next day or so. This well still down, looking for hole in the casing but rig will go on new well - they believe they can run packer, tubing and start injecting as they found no new/additional perfs in this well (#7958). Repeated that I needed to be there when packer goes in. |
1237988515 | 2009-03-24 | Salt Water Injection Well | No Violations | Inspection this day found service rig has moved back over well. Producing casing has hole, injection not possible as cant hold pressure. Previously, packer and tubing had been pulled from well, plug set below the perfs and retainer had been set above, well reperfd above the cement. Retainer and plug provided the opportunity to circulate after casing perfd to prove well is circulating, zone can be squeezed. Well would not circulate so plans are to get a pump truck in, pressure up on the well to see if circulation can be realized, then cement backside of casing up past where hole is in 4.5 casing. If that doesnt work, will make into a producer in the Cow Run Sand. |
1252591045 | 2009-09-07 | Salt Water Injection Well | No Violations | Inspection this day --4 hook-wall packer going into hole - new rubber on it - and then tubing. Tubing/bottom of packer ran to 1779.7 Will pressure test tomorrow. |
1255799910 | 2003-10-09 | Salt Water Injection Well | No Violations | Inspection this day found well still very messy with oil and saltwater in pit. Hose connected to pump in pumphouse leaking saltwater. Also need fence or gate as horse prints around pit. Contacted Operator and gave verbal NOV requesting removal of all contaminated soil, check pit liner to make sure still good, repair leaking hose, and remove all water from pit. Gave operator 2 weeks |
1304906615 | 2013-03-18 | Salt Water Injection Well | No Violations | Inspection revealed that well was not in operation and owner still needs to have tanks removed and cleaned out and containment area fixed up and drains from pump house plumbed to vault area. |
1307377426 | 2011-06-02 | Salt Water Injection Well | No Violations | Inspection found pit has been sucked out, still small amount of oil they need to get out. No lime spread yet and called Smitty and asked him to get it done soon. Said he would, he thought Millard had done it. |
1310991737 | 2011-07-14 | Salt Water Injection Well | No Violations | Met with Millard Carper - says he has put lime down, can he start using well again? I said to sow grass seed, give it alittle time to grow. Pump dike out and keep it dry. He seems to think dike was full, due to many rains, and simply ran over when got full to the top - shouldnt have been brine. I am willing to restart back up, when kill area is reclaimed, on the condition they keep water out of the dike area. Can start back up and test Millards theory before replacing all the liner. He says he also needs to clean out sump hole and that will help keep dike dry inside. |
1317237266 | 2011-09-28 | Salt Water Injection Well | No Violations | Inspection this day found pump not running, about 4 fresh water inside dike. Rained in last day so probably have not pumped it out yet - told them to keep it empty. Kill area below the dike starting to grow back but not satisfactory yet. Good IDs - still have to fix/repair plastic liner or prove it is not leaking. |
1344501040 | 2003-02-11 | Salt Water Injection Well | No Violations | (3) housekeeping unloading pad
(4)inside of dike area needs a good cleaning (11)house keeping in unloading pad area No violations noted this inspection. |
1360095314 | 2008-02-28 | Salt Water Injection Well | No Violations | Inspection this day found quarterly requirement. Well not in production, pumphouse door shut with lock so believe not getting much water. Pump not running. Went back to well and gauges show both annulus and tubing on 0#. Water was in dike area at tank but was froze - this well difficult to get to, had to go when froze instead of waiting another couple weeks when road would be thawed out and muddy. |
1383591326 | 2013-11-04 | Salt Water Injection Well | No Violations | Inspection on this day indicated that owner is presently installing new pit liner in tank area and placing sand on top of liner to help hold it in place. |
1392129284 | 2007-05-31 | Salt Water Injection Well | No Violations | Called Carper and informed time for yearly pressure test - well down producing this day but did not do pressure test - will wait until next week for yearly. |
1394934178 | 2009-09-08 | Salt Water Injection Well | No Violations
-10# in 15 minute period. Passed test. Well tied into line, IDs back up and back taking water. I requested pit be emptied this day and filled in - cattle in the area and needed area cleaned up to avoid any livestock problems. Chief Orders resolved. | |
1403904313 | 2014-06-26 | Salt Water Injection Well | No Violations | Inspection revealed that owner has removed old tanks from facility and they are waiting on new storage tanks to be delivered to site and placed in storage area. |
1408315368 | 2014-08-13 | Salt Water Injection Well | No Violations | Inspection revealed that owner has recently placed two 100 bbl. tanks at site and they plan on setting more storage tanks in the near future and also they plan on replacing flow line to both wells on the lease before placing them back into operation. |
1411817526 | 2014-09-23 | Salt Water Injection Well | No Violations | On site to hydro test new flow line and pressure test annulus of tubing company rep pumped fresh water through flow line and we tested it at 560 psi with no decline in pressure and then we moved on to performing annulus testing they placed 530 psi on annulus and we monitored pressure for 15 minutes with no decline in pressure. |
1425331649 | 2015-03-02 | Salt Water Injection Well | No Violations | Inspection revealed that well is not in operation at this time, owner has rebuilt facility and they are waiting on better weather so they can cover exposed portions of containment liner so it wont rot due to exposure to the sunlight. |
1427205444 | 2015-03-23 | Salt Water Injection Well | No Violations | Inspection revealed that owner has completed remedial work required at site and is ready to place wells on the lease back into operation.
Note: Witnessed MIT testing on annulus of tubing today owner applied 550 psi and we monitored pressure for 15 minutes with no decline in pressure. Dike measurements are as follows 25X50X48TALL with a calculated volume of 888 bbl. |
1433281537 | 2015-05-29 | Salt Water Injection Well | No Violations | On site to witness MIT Testing of annulus of tubing and ensuring that they have good casing integrity company rep applied 585 psi of pressure and we monitored pressure for 15 minutes with no decline in pressures.(TEST PASSED) |
1436765132 | 2006-05-24 | Salt Water Injection Well | No Violations | Inspection this day found well looking pretty good, no big messes, pump not running. |
1447025193 | 2016-07-06 | Salt Water Injection Well | No Violations | Inspection today revealed that well is not in operation at this time,owner is currently hauling water too there other facility in Noble county. |
1455022409 | 2003-03-13 | Salt Water Injection Well | No Violations | No violations noted
(3)tank area needs cleaned(remove oily soil in tank area+replace with stone to protect liner in dike area. If storing oil in tank beside of pump house tank will need tobeI.D.ed+diked |
1459624320 | 2017-02-08 | Salt Water Injection Well | No Violations | Inspection revealed that well is not in operation at this time but I had owner come out and perform mini pressure test on annulus of tubing to ensure the division of casing integrity. |
1482799903 | 2016-09-06 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was not in operation and it was noted that injection line right away has been recently brush hogged and there was a worker on site weed eating around containment area during my inspection. |
1484495878 | 2013-07-24 | Salt Water Injection Well | No Violations | Accompanied UIC III inspector Dave Ball on inspection of this well and tank battery. The tank battery has an excessive amount of fluid in it with oily fluid on top. |
1517664349 | 2019-9-17 0:00: | SW | No Violations | |
1538867436 | 2011-05-24 | Salt Water Injection Well | Violations Noted | Inspection this day found pump not running. When looked over the facility, found brine kill area below and off to the side of the dike - looks like plastic liner has failed and brine has went beneath the dike brim, under the liner and killed vegetation in an area 100 x 25. Called operator and told him would need to shut down until issues are resolved - liner may have to be replaced and tanks removed from dike to do that. Have often found water inside the dike and tanks seem to overflow, thus the brine remains inside the dike and has travelled under the plastic. Carper in agreement, will start by liming the spot, then determine and fix leakage. 6/11/12 - Talked to Ryan Carper - he says lease is about to run out - |
1577064649 | 2009-12-01 | Salt Water Injection Well | No Violations
-- Checked pressures - pump not running has hasnt run for awhile. 0# on tubing, 0# on annulus - will have to check when pump running to verify there is difference. Inside dike area is completely dry - looks good! | |
1595438252 | 2020-7-21 0:00: | SW | No Violations | |
1604197124 | 2013-10-04 | Salt Water Injection Well | No Violations | Clean up continues at site owner has removed all storage tanks from dike area and is in process of removing all contaminated material from dike area and once all material is removed they will begin rebuilding facility. |
1606053051 | 2008-06-18 | Salt Water Injection Well | No Violations | Inspection this day for yearly pressure test. Well was shut off when we got there. Millard present to perform test, had to fill annulus with 32 gal water - when pressured up to 200#, did not hold and gradually fell to 0 over a period of 15-20 minutes. Millard was afraid it would not hold as had tested it early in the month and had taken it up to 400-500# which he realized later had hurt its integrety. Must have small hole in casing. Pressure test on tubing while pump running was 530# - this part passes and well is in no danger of contaminating ground water or other formations. Called Tom Tomastik to see what he wanted operator to do but I believe will have to fix casing. |
1616091438 | 2008-08-28 | Salt Water Injection Well | No Violations | Well still has Chiefs Orders due to hole in casing. Millard says he is going to try to fix and then will continue to use. Still down this day. |
1650540372 | 2003-11-04 | Salt Water Injection Well | No Violations | Inspection this day found disposal site and location still not cleaned up. Called Operator and he was sending someone out today to get started on cleanup. Will recheck soon. |
1684661490 | 2009-08-27 | Salt Water Injection Well | No Violations | Service rig on location today, sending mandrel down to make sure casing is clear and clean before running packer on tubing. Millard Carper present and says well has been logged to find hole in casing, plug set below hole, casing perfd and squeezed to repaid/seal off hole, plug removed and well now ready to get back in operation. Plans are to run rebuilt packer next week and will call me before doing so. |
1692665486 | 2014-05-12 | Salt Water Injection Well | No Violations | Inspection revealed that owner has two more old tanks to be removed from site before they can start setting new storage tanks in dike area and it was discussed that they will replace flow line going to well head before placing well into operation. |
1743901733 | 2003-09-02 | Salt Water Injection Well | No Violations | No violations noted this inspection,facility appears to be in good repair.
(3)clean up in tank area needed. (11)housekeeping in unloading area needed Note:Walked flowline |
1747602971 | 2008-06-03 | Salt Water Injection Well | No Violations | Inspection for quarter - time for yearly pressure test and have scheduled 2Xs and had to cancel. Will get done in next week or so. Today well not running, pit/dike area fairly dry - better than some other visits. |
1757223329 | 2013-08-20 | Salt Water Injection Well | No Violations | On site to witness clean up efforts being made at site, owner is removing material from tank area and hauling it to a approved landfill and once all solids and liquids are removed they will remove tanks and then start rebuilding process of entire storage facility. |
1772252492 | 2014-03-10 | Salt Water Injection Well | No Violations | Inspection revealed that well is down waiting on owner to complete rebuilding of storage tank facility. |
1803067738 | 2015-11-17 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today. |
186316124 | 2017-8-24 0:00: | SW | No Violations | |
1888978830 | 2012-04-12 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today and it appears that well has been out of service for quite some time, it has been noted that Green Hunter is working on service agreement with Carper to operate well and clean up existing issues at facility. |
1955540783 | 2007-10-18 | Salt Water Injection Well | No Violations | Inspection this day was to meet with Dean Decker - can turn pump on so I can check pressures. He said Carper has had well acidized with 1200 gal. Of 15% - when I checked pressure it was at 530# which is the maximum limit. Carper has also cleaned out storage tanks, dike area is dry but still black from the water running over the tanks and coloring the gravel. Dean thinks it is more black water than oil. Will go ahead and clear NOV with the understanding that they must keep the dike area dry and continue to try and clean it up more. Pressure is passable. |
1957627969 | 2018-04-25 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was not in operation during my inspection. |
1968010362 | 2017-06-12 | Salt Water Injection Well | No Violations | Well not in operation at this time. |
2004688845 | 2013-07-24 | Salt Water Injection Well | Violations Noted | Inspection revealed that there was brine&oil within dike area and it appeared that someone had recently ran tanks over and owner has not complied with previous Compliance notice issued 5/24/11 for contamination at surface facility and dike not being liquid tight because it appears to be leaking because we ran Quantab test in water hole and they indicated that there was brine present outside of dike.
Note: Photos were taken and water samples were taken to Cambridge lab to be analyzed, Note: To properly fix dike owner will need to have tanks cleaned and removed from dike area and new liner installed after all contaminated material is removed from dike area and replaced with fresh soil and properly place identification at wellhead with complete information. |
2013257317 | 2007-06-06 | Salt Water Injection Well | No Violations | Completed yearly injection pressure test this day. Pressured up annulus to 100# - pump was not working correctly and couldnt get any higher. Held 100# for 15 min - tubing tested at 318# - also held. Operator says he had pressured up annulus on Monday (this is Wednesday) and when we arrived, annulus was back to 0 already - this well never holds its annulus pressure, yet feel if there was a pipe or packer failure, we would see a rapid fall. I feel this pipe good but standard test requires 200# for 15 min. Pumphouse had been steam cleaned, looks good, fair amount of crusty, old oil in dike area but no water. Pump running this day |
2021086250 | 2007-02-28 | Salt Water Injection Well | No Violations | Inspection this day found dike area full of fresh water. Pump was running, would have liked to put my gauge on well, but valve to shut was not shutting. Contacted operator and asked to put a new gauge on - gauge read 700# and he was sure gauge was not reading correctly - and install a new valve so I could shut to put my own gauge on. No longer gauge in pumphouse - not required. Too muddy to back to well again today, or this week - will try to get a good test next week. Carper W. S. truck unloading water. |
2074430978 | 2005-03-18 | Salt Water Injection Well | No Violations | Inspection this day found site still messy - never changes - hauler has spilled some oil on unloading pad and they have had broom out, trying to clean up. Fresh water in dike area but no oil this time. Injection well looks OK, up to 350# and pump not running. Good IDs, new needle valve on well. |
2084257862 | 2010-03-09 | Salt Water Injection Well | No Violations | Inspection this day found pump running, well tested 370# on tubing, 0# on annulus. Very muddy, had to walk in to wells. Small amt fluid in dike area, good IDs at well and at house. |
291217080 | 2007-12-10 0:00 | SW | No Violations | |
357816093 | 2004-5-6 0:00:0 | SW | No Violations | |
366523147 | 2009-2-19 0:00: | SW | No Violations | |
444319928 | 2012-3-5 0:00:0 | SW | No Violations | 0.70 |
519100718 | 2005-5-27 0:00: | SW | No Violations | |
519329515 | 2014-1-15 0:00: | SW | No Violations | |
585139923 | 2002-3-14 0:00: | SW | No Violations | |
889290563 | 2018-12-6 0:00: | SW | No Violations | |
999710244 | 2013-2-12 0:00: | SW | No Violations | |
UIC1000 | 1990-10-12 0:00 | SW | No Violations | |
UIC1703 | 1997-7-28 0:00: | SW | No Violations | |
UIC1798 | 1999-9-17 0:00: | SW | No Violations | |
UIC1799 | 1999-9-17 0:00: | SW | No Violations | |
UIC1800 | 1999-9-17 0:00: | SW | No Violations | |
UIC915 | 1990-5-17 0:00: | SW | No Violations | |
UIC999 | 1990-10-12 0:00 | SW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0436577129 | US-OH-124556 | 2019-04-08 | Failure to report disposal fees | |
0525219068 | US-OH-125736 | 2007-09-18 | Pollution/Contamination | |
0525219068 | US-OH-125737 | 2007-09-18 | Exceeding maximum allowable injection pressure | |
0525219068 | US-OH-125738 | 2007-09-18 | Failure to monitor pressures/volumes | |
0525219068 | US-OH-125739 | 2007-09-18 | Failure to monitor annulus pressure | |
1082080785 | US-OH-101858 | 2005-05-19 | Contamination at surface facility (permit after 6-1-82) | |
1538867436 | US-OH-114860 | 2014-04-23 | Contamination at surface facility (permit before 6-1-82) | |
1538867436 | US-OH-114861 | 2014-04-23 | Pits not liquid tight/Improper construction or use | |
2004688845 | US-OH-120340 | 2014-04-10 | Pollution/Contamination | |
2004688845 | US-OH-120341 | 2014-04-10 | Contamination at surface facility (permit after 6-1-82) | |
2004688845 | US-OH-120342 | 2014-04-10 | Permit not displayed | |
2004688845 | US-OH-120343 | 2014-04-10 | Pits not liquid tight/Improper construction or use | |
2004688845 | US-OH-120344 | 2014-04-10 | Failure to repair pits/Unlawful use of pits |