X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-121-23390"

m
m
 
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-121-23390
 
| Well ID: 34-121-23390
| style="height=100%; align=center" rowspan="17" | {{#display_map: 39.777227951, -81.54713202 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 39.77, -81.54 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 29: Line 29:
 
| Final Drill Date: 1984-12-31
 
| Final Drill Date: 1984-12-31
 
|-
 
|-
| Well Total Depth: 5563 ft
+
| Well Total Depth: 5563.00 ft
 
|-
 
|-
 
| Configuration: Vertical
 
| Configuration: Vertical
 
|-
 
|-
| Latitude: 39.777227951
+
| Latitude: 39.770000
 
|-
 
|-
| Longitude: -81.54713202
+
| Longitude: -81.540000
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
 
  | title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 
  | title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date =  2019-05-07
+
  | date =  2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
== Well History ==
 
== Well History ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 125: Line 125:
 
  | title = Risk Based Data Management System - Well and WellHistry Tables
 
  | title = Risk Based Data Management System - Well and WellHistry Tables
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2019-05-07
+
  | date = 2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
== Perforation Treatments ==
 
== Perforation Treatments ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 144: Line 144:
 
| style="text-align: right;" | 5447
 
| style="text-align: right;" | 5447
 
| style="text-align: right;" | 1
 
| style="text-align: right;" | 1
 +
|-
 +
|
 +
| style="text-align: right;" | 5327
 +
| style="text-align: right;" | 5447
 +
| style="text-align: right;" | 1
 +
|-
 +
|
 +
| style="text-align: right;" | 4603
 +
| style="text-align: right;" | 4606
 +
| style="text-align: right;" | 12
 +
|-
 +
|
 +
| style="text-align: right;" | 4603
 +
| style="text-align: right;" | 4606
 +
| style="text-align: right;" | 12
 
|-
 
|-
 
|}
 
|}
Line 149: Line 164:
 
  | title = Risk Based Data Management System - Perfs Table
 
  | title = Risk Based Data Management System - Perfs Table
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date =  2019-05-07
+
  | date =  2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
<!--== Fracking Activities ==
 
<!--== Fracking Activities ==
 
==== Fracking Jobs ====
 
==== Fracking Jobs ====
Line 198: Line 213:
 
  | title = Risk Based Data Management System - tblStimulation Table
 
  | title = Risk Based Data Management System - tblStimulation Table
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date =  2019-05-07
+
  | date =  2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 211: Line 226:
 
| 1985
 
| 1985
 
| [[WALHONDING ENERGY CO]]
 
| [[WALHONDING ENERGY CO]]
| style="text-align: right;" | 3147
+
| style="text-align: right;" | 3147.00
| style="text-align: right;" | 0
+
| style="text-align: right;" | 0.00
 
| style="text-align: right;" | 0
 
| style="text-align: right;" | 0
 
|-
 
|-
 
| 1986
 
| 1986
 
| [[WALHONDING ENERGY CO]]
 
| [[WALHONDING ENERGY CO]]
| style="text-align: right;" | 656
+
| style="text-align: right;" | 656.00
| style="text-align: right;" | 0
+
| style="text-align: right;" | 0.00
 
| style="text-align: right;" | 365
 
| style="text-align: right;" | 365
 
|-
 
|-
Line 225: Line 240:
 
  | title = Risk Based Data Management System - Production Table - Oil and Gas Data
 
  | title = Risk Based Data Management System - Production Table - Oil and Gas Data
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date =  2019-05-07
+
  | date =  2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
<ref>{{cite web
 
<ref>{{cite web
 
  | title = Combined Production - Oil and Gas Data
 
  | title = Combined Production - Oil and Gas Data
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2019-05-07
+
  | date = 2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
== Waste Data ==
 
== Waste Data ==
 
{| class="wikitable sortable"
 
{| class="wikitable sortable"
Line 258: Line 273:
 
  | title = Risk Based Data Management System - Production Table - Brine Data
 
  | title = Risk Based Data Management System - Production Table - Brine Data
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date =  2019-05-07
+
  | date =  2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
<ref>{{cite web
 
<ref>{{cite web
 
  | title = Combined Production - Brine Data
 
  | title = Combined Production - Brine Data
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2019-05-07
+
  | date = 2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 
==== Inspections Performed ====
 
==== Inspections Performed ====
Line 276: Line 291:
 
!scope="col" style="text-align: center"| Inspection Comments
 
!scope="col" style="text-align: center"| Inspection Comments
 
|-
 
|-
| 00005604i4
+
| -1032171774
 +
| 2011-6-10 0:00:
 +
| SW
 +
| No Violations
 
|  
 
|  
| Salt Water Injection Well
+
|-
 +
| -1036095644
 +
| 2015-1-9 0:00:0
 +
| SW
 
| No Violations
 
| No Violations
|  
+
| 6.00
 
|-
 
|-
| 0005377227
+
| -1100645896
| 2002-08-13
+
| 2015-5-20 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
 
|  
 
|  
 
|-
 
|-
| 0005604i34
+
| -1202476629
| 2002-01-16
+
| 2007-1-2 0:00:0
| Work Over Reconditioning
+
| SW
 
| No Violations
 
| No Violations
 
|  
 
|  
 
|-
 
|-
| 0005604i63
+
| -1207662360
| 2002-02-06
+
| 2012-2-10 0:00:
| Work Over Reconditioning
+
| SW
 
| No Violations
 
| No Violations
 
|  
 
|  
 
|-
 
|-
| 000UIC1727
+
| -1211473851
| 1998-06-25
+
| 2015-5-7 0:00:0
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| 1501: 9-9-05 (10)  IDENTIFICATION
+
|  
 
|-
 
|-
| 001259i193
+
| -1230648854
| 2002-10-30
+
| 2011-4-28 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
 
|  
 
|  
 
|-
 
|-
| 0048328763
+
| -1252803534
| 2005-01-06
+
| 2014-10-27 0:00
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
|  
Noted:Three Key Energy tankers unloading brine during my inspection.
 
(11) Housekeeping needed in unloading area,stone needed in driveway area.
 
Tank area in need of a good steam cleaning!
 
 
|-
 
|-
| 005604i102
+
| -1254363886
| 2002-03-19
+
| 2010-12-29 0:00
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
|     Cleaning Tanks Preparing to place well in service.
+
|  
 
|-
 
|-
| 005604i169
+
| -1274296236
| 2002-04-26
+
| 2020-10-9 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
|   Hooking up pumps.
+
| 1.00
 
|-
 
|-
| 005604i206
+
| -1296272525
| 2002-05-09
+
| 2010-3-30 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
 
|  
 
|  
 
|-
 
|-
| 005604i224
+
| -1305694384
| 2002-05-17
+
| 2006-4-4 0:00:0
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
|   1st. Test on pipeline failed due to a well head leak.  2d. Test failed due to pipeline leak.    New curb poured for loading pad.
+
|  
 
|-
 
|-
| 005604i225
+
| -1351488117
| 2002-05-21
+
| 2004-5-10 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
|     Pipeline from pump to well tested at 1510psi. For 30min. Pressure did not drop.    Test Approved.
+
| 2.00
 
|-
 
|-
| 0085278170
+
| -1376609958
| 2002-05-06
+
| 2018-5-14 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| operator working on unloading pad. Carper well service is the owner!
+
|  
 
|-
 
|-
| 0087066765
+
| -1384500063
| 2014-11-03
+
| 2009-2-12 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| On site to witness rig operator pull tension on tubing string and then try and tighten up tubing head to stop small leak noted on previous inspection.
+
|  
 
|-
 
|-
| 0114208207
+
| -1417405530
| 2007-10-03
+
| 2015-10-21 0:00
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
|  
Note: Owner is in process of cleaning out storage tanks called his office and left message that I will need run tickets to verify proper disposal of tank waste.
 
 
|-
 
|-
| 0149493778
+
| -1419161005
| 2015-12-16
+
| 2003-6-2 0:00:0
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was in operation today and it was noted that two Ramco vacuum trucks were unloading at the facility on this day.
+
|  
 
|-
 
|-
| 0174001850
+
| -1428603162
| 2017-04-28
+
| 2015-9-9 0:00:0
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection today revealed that injection pump was in operation during my inspection.
+
|  
 
 
Note: Weedeating needed in area of wellhead and flowline area.
 
 
|-
 
|-
| 0185563784
+
| -1432751271
| 2006-05-02
+
| 2016-11-8 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
|  
Note:Operator is trying to clean up tank area(stills has a way to go) but is putting some effort into getting facility up into 21st Century industry standards.
 
Walked flow line no leaks found.
 
 
|-
 
|-
| 0210366979
+
| -1435892970
| 2015-04-27
+
| 2009-10-8 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Company owned  service rig on well cleaning out wellbore they were at 5251 with bit and hope to have interior of casing cleaned out by early next week.
+
|  
 
|-
 
|-
| 0214838369
+
| -1450120219
| 2014-01-24
+
| 2009-9-4 0:00:0
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection revealed that well is still down waiting on owner to submit rebuild plan for facility.
+
|  
 
|-
 
|-
| 0216435958
+
| -1455312752
| 2015-04-15
+
| 2016-12-21 0:00
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection revealed that service rig was pulling tubing and milling tools from well bore to replace milling tool this one has stopped cutting up debris.
+
|  
 
|-
 
|-
| 0225655085
+
| -1475831093
| 2005-09-23
+
| 2015-1-27 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| No violations noted ,facility appers to be in satisfactory condition this inspection.
+
|  
Called well owner and stated that entire plumbing system at storage site is in need of being replaced due too fact that band clamps that they have in place are seeping,also noted that 210bbl storage tank is leaking from heater tube and is in need of being repaired or replaced,also told operator that entire tank area is in need of a good steam cleaning he stated he would start repairs 9/26/05 weather permitting.
 
 
|-
 
|-
| 0250911662
+
| -149493778
| 2017-02-08
+
| 2015-12-16 0:00
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| On site to witness mini pressure test on annulus of tubing,injetion pup was in operation during my inspection.
+
|  
 
|-
 
|-
| 0259846312
+
| -1525433948
| 2019-02-12
+
| 2011-9-14 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was not in operation during my inspection.
+
|  
 
 
 
 
Note: Inside of tank area is in need of a good cleaning noticed trace amount of sheen in water within containment area.
 
 
|-
 
|-
| 0275102970
+
| -1553522418
| 2008-07-03
+
| 2020-1-15 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection
+
|  
Note: Requested owner to replace 2 high pressure hose @wellhead the one in use is showing signs of  defects.
 
 
|-
 
|-
| 0286257119
+
| -1564672871
| 2017-05-24
+
| 2015-1-8 0:00:0
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection today revealed that injection pump to this well was in operatin today and it was noted that one company owned  tanker was unloading at the facility during my inspection.
+
|  
 
|-
 
|-
| 0288665557
+
| -1581297244
| 2007-07-09
+
| 2008-4-2 0:00:0
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
|  
Note: Pump was not in operation during my inspection, noted stainingon unloading pad apparently  truck had a bad leak in valve during unloading procedure.House keeping needed in tank area operator needs to clean out tanks to allow for more for more volume of brine .
 
 
|-
 
|-
| 0345539737
+
| -1635545047
| 2007-02-06
+
| 2005-12-8 0:00:
| Salt Water Injection Well
+
| SW
 +
| No Violations
 +
|
 +
|-
 +
| -1819170680
 +
| 2007-5-3 0:00:0
 +
| SW
 
| No Violations
 
| No Violations
| No violations noted facility appears to be in satisfactory condition this inspection.
+
|  
Noted company owned tanker parked on unloading pad no truck attached,suggest placing tub under valve on tanker too catch salt water dripping from connections.
 
 
|-
 
|-
| 0371683144
+
| -1826454894
| 2010-05-21
+
| 2015-1-7 0:00:0
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection revealed that pump was in operation during my inspection.
+
| 3.00
Note: Area around wellhead is in need of restoration work preformed,area needs to be seeded&mulched to prevent eroision issues that might arise and road to wellhead is in need of stone.
 
 
|-
 
|-
| 0386632174
+
| -1841534296
| 2012-11-07
+
| 2016-3-24 0:00:
| Production Wells
+
| SW
 
| No Violations
 
| No Violations
| My inspection today finds that the well has 100 psi. on the 4.5 casing, and 280 psi. on the 2.375 tubing.
+
|  
 
|-
 
|-
| 0387365330
+
| -1890846684
| 2008-06-02
+
| 2004-10-18 0:00
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| 1.50
Note: Pump was not operating during my inspection also walked flow line area to monitor area for potential leaks none found, tank area has been somewhat cleaned sealant in cracks needs to be replaced (not what your using at present date its not oil/brine compatible!!
 
 
|-
 
|-
| 0391155921
+
| -1952207672
| 2017-08-29
+
| 2020-5-15 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection today indicated that injection pump was not in operation due to fact that Producers Services was on site performing 2000 gallon acid treatment on said well.
+
|  
 
|-
 
|-
| 0395414581
+
| -2019628224
| 2015-10-01
+
| 2005-2-4 0:00:0
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection on this day indicated that injection pump was not in operation during my inspection and it was noted that owner was having new lighting installed at the facility.
+
|  
 
|-
 
|-
| 0427080007
+
| -2037920083
| 2017-02-22
+
| 2014-12-10 0:00
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection today revealed that injection pump was not in operation during my inspection.
+
|  
 
|-
 
|-
| 0429657617
+
| -2091704699
| 2017-08-24
+
| 2020-4-23 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection today indicated that injection pump was in operation and operating at maximum allowable pressure and it was noted that two company owned vacuum trucks were unloading at the facility during my inspection.
+
|  
 
|-
 
|-
| 0434747279
+
| -2100004227
| 2015-09-25
+
| 2016-1-6 0:00:0
| Salt Water Injection Well
+
| AD
 
| No Violations
 
| No Violations
| On site to do walkthrough with operator prior to placing well back into operation, all plumbing has been replaced and new 300 bbl. Tanks installed and new pump house has been constructed and once electrical work is completed owner will resume operations at this site.
+
|  
 
|-
 
|-
| 0435286527
+
| -2102879171
| 2010-02-02
+
| 2015-12-29 0:00
| Salt Water Injection Well
+
| SW
| Violations Noted
+
| No Violations
| Inspection revealed that well has equalizedcalled company and let them be aware of suspension order,call central office and requested order be issued for said well. Repair tubing /packer and properly perform required testing before placing well back into operation.
+
|  
 
 
Failure to comply may result in bond forfeiture.
 
 
|-
 
|-
| 0438810527
+
| -210366979
| 2015-02-02
+
| 2015-4-27 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection revealed that company owned service rig was pulling tubing from well and changing out bit and once they get cement retainer drilled up and they get below perforations they will pressure test casing for integrity.
+
|  
 
|-
 
|-
| 0440372304
+
| -2130911311
| 2015-09-14
+
| 2015-5-18 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection on this day indicated that owner is nearly complete with rebuilding of facility and we pressure tested flow line to wellhead at 1400 psi with no pressure loss and I reminded owner that new identification needed to be posted on tanks and also wellhead.
+
|  
 
|-
 
|-
| 0451380060
+
| -2133064485
| 2007-06-05
+
| 2017-3-14 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
|  
Pump was not in operation during my inspection,called well owner and suggested that they have well tender weedeat path to wellhead and steamclean tank area ASAP.
 
 
|-
 
|-
| 0458578328
+
| -2143814339
| 2016-05-31
+
| 2018-3-11 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was in operation today.
+
|  
 
|-
 
|-
| 0479689203
+
| -225655085
| 2015-11-17
+
| 2005-9-23 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was in operation during our inspection today.
+
|  
 
|-
 
|-
| 0480021501
+
| -288665557
| 2015-01-05
+
| 2007-7-9 0:00:0
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection on this day revealed that company owned service rig was running a test packer in well to locate possible hole in casing and once they pinpoint it they will perform cement squeeze job to repair casing.
+
|  
 
|-
 
|-
| 0495884058
+
| -345539737
| 2016-09-07
+
| 2007-2-6 0:00:0
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| On site to witness mini pressure test on annulus of tubing they applied 500 psi of pressure and we monitored it for 15 minutes with no decline in pressure.
+
|  
 
|-
 
|-
| 0524935433
+
| -371683144
| 2008-12-04
+
| 2010-5-21 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection revealed that pump was not in operation during my inspection.
+
|  
Note:As weather permits housekeeping is needed  in tank area also noted damp conditions around cleanout plate on several 210 bbl tanks suggest empty tanks and reseal cover plates.
 
 
|-
 
|-
| 0528958761
+
| -391155921
| 2018-04-02
+
| 2017-8-29 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection revealed that there was no activity at the site during my inspection.
+
|  
 
|-
 
|-
| 0543784100
+
| -435286527
| 2009-05-12
+
| 2010-2-2 0:00:0
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection this day found Producers Service Co. acidizing injection well.  Used 2000 gal. Of 15% acid and well taking it fairly easily.
+
|  
 
|-
 
|-
| 0557678394
+
| -438810527
| 2014-10-30
+
| 2015-2-2 0:00:0
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection revealed that concrete has been put in place and workers are proceeding along with getting well back into operation.
+
| 2.00
 
|-
 
|-
| 0561435102
+
| -440372304
| 2015-04-06
+
| 2015-9-14 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Stopped by service rig for update and they have retrieved bridge plug and now they are making site ready to go back in well and start drilling out cement retainer.
+
|  
Note: Stopped at recently rebuilt containment area and tested water for chlorides none were detected after running quantab strip test.
 
 
|-
 
|-
| 0572190922
+
| -524935433
| 2010-12-09
+
| 2008-12-4 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was not in operation during my inspection.
+
|  
Note: Platform needs to be constructed at well head so inspector can properly remove gauge and monitor pressures at wellhead. Also noted that all storage tanks have been cleaned out and resealed and partially replumbed.
 
 
|-
 
|-
| 0585855735
+
| -53123739
| 2015-04-17
+
| 2019-9-26 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection revealed that power swivel broke down and owner is currently making repairs on swivel and they will resume workover procedure within the next couple of days.
+
|  
 
|-
 
|-
| 0599281069
+
| -557678394
| 2011-03-26
+
| 2014-10-30 0:00
| Annular Disposal
+
| SW
 
| No Violations
 
| No Violations
| Call from EMS in Noble Co. regarding a fire at disposal well south of Belle Valley.  Responded to call, observed fire and the extingushing of it - took many pictures.
+
|  
 
|-
 
|-
| 0602395613
+
| -585855735
| 2003-09-04
+
| 2015-4-17 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| No violations noted,facility appears to be in good condition.
+
|  
(3)oil tank still needs replaced
 
(11)housekeeping needed in unloading area
 
lease road to wellhead needs dressed up
 
Suggest replacing hoses at unloading site (camlock ends are getting worn)
 
Note:Walked flowline.
 
 
|-
 
|-
| 0636816591
+
| -599281069
| 2018-12-27
+
| 2011-3-26 0:00:
| Salt Water Injection Well
+
| AD
 
| No Violations
 
| No Violations
| Inspection today revealed that injection pump was in operation and it was noted that one company owned vacuum truck was offloading at the facility during my inspection.
+
| 4.00
 
|-
 
|-
| 0675004728
+
| -620810822
| 2008-05-07
+
| 2020-10-14 0:00
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactor condition this inspection.
+
| 6.00
Note: Tank area is in need of a severe steam cleaning and trash dumpster is in need of repacement it has hole in bottom seeping residue from filter changes,also 2 nipple on elbow is in need of thread tape replacement@ wellhead.
 
 
|-
 
|-
| 0678997720
+
| -636816591
| 2019-04-01
+
| 2018-12-27 0:00
| Salt Water Injection Well
+
| SW
 +
| No Violations
 +
|
 +
|-
 +
| -678997720
 +
| 2019-4-1 0:00:0
 +
| SW
 
| No Violations
 
| No Violations
| Inspection today indicated that injection pump was in operation during my inspection.
+
|  
 
 
Noted one company owned vacuum truck on site during my inspection.
 
 
|-
 
|-
| 0679021003
+
| -679021003
| 2015-04-02
+
| 2015-4-2 0:00:0
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Service rig still on site attempting to remove bridge plug that was set in well bore they have gotten a hold of it and are coming out of the hole with it today.
+
|  
 
|-
 
|-
| 0708379192
+
| -708379192
| 2015-02-04
+
| 2015-2-4 0:00:0
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| On site to witness pressure test of 4.5 casing they pressured up to 1250 psi and we monitored pressure for 15 minutes with a 10# loss(TEST PASSED).
+
|  
 
|-
 
|-
| 0716431656
+
| -716431656
| 2014-10-29
+
| 2014-10-29 0:00
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| On site to witness crew place stone on exterior of containment wall to help strengthen it and on this day they formed up area for the new pump house and trash bin area and if weather permits they will place concrete tomorrow.
+
|  
 
|-
 
|-
| 0757321958
+
| -759916444
| 2015-05-21
+
| 2013-8-20 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Timco on site to log well and possibly reperforate casing.
+
| 1.00
 
|-
 
|-
| 0759916444
+
| -795119875
| 2013-08-20
+
| 2008-10-2 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| My inspection today revealed that the injection well is still shut down awaiting the owner to rebuild the tank facility and pump house, they had fire at facility a couple years ago.
+
|  
 
 
 
|-
 
|-
| 0766214683
+
| -809104420
| 2016-05-18
+
| 2018-10-5 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection today revealed that injection pump was in operation and it was noted that one RAMCO bottle trucks was on site unloading during my inspection,
+
|  
 
|-
 
|-
| 0785092645
+
| -844377490
| 2015-01-30
+
| 2013-12-13 0:00
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Stopped by service rig for update they were still drilling cement retainer out  and operator stated that he could be ready to pressure test casing integrity tomorrow if they get hole cleaned up.
+
|  
 
|-
 
|-
| 0788205253
+
| -85278170
| 2015-03-31
+
| 2002-5-6 0:00:0
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Company owned rig milling on bridge plug they hope to pull it from well later this week.
+
|  
 
|-
 
|-
| 0795119875
+
| -855505376
| 2008-10-02
+
| 2007-11-16 0:00
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection revealed that well was not in operation during my inspection, well tender was replacing plumbing on tubing head 2 high pressure elbow was replaced and other assorted fittings also, tank area is in need of a good cleaning while the weather is favorable.
+
|  
 
|-
 
|-
| 0809104420
+
| -87066765
| 2018-10-05
+
| 2014-11-3 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| On site to witness acid treatment job 2000 gallon of 28% HCL was pumped and ISIP was noted at 1107 and after 10 minutes it was noted at 896 psi  Producers rigged down and job was deemed complete.
+
|  
 
|-
 
|-
| 0844377490
+
| -874994452
| 2013-12-13
+
| 2005-6-1 0:00:0
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection revealed that well is still down waiting on owner to submit rebuild plan to division.
+
| 1.50
 
|-
 
|-
| 0855505376
+
| -938018689
| 2007-11-16
+
| 2020-10-8 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Complaint called in from OHIO EPA(Dennis Deavers) of strong odor of sulfur smell near tank site,upon inspecting site found that operator had unloaded tanker truck prior to my inspection apparently source of smell derived from water source from unknown source in adjoining state, contacted well owner Millard Carper and discussed issues at well site, received several complaints from local citizens about odor told them smell would dissipate in time.
+
| 4.00
 
|-
 
|-
| 0874994452
+
| -939477225
| 2005-06-01
+
| 2009-11-3 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| No violations noted facility appears to be in satisfactory condition this inspection.
+
|  
Noted that partial cleanup in tank area has been preformed lots more to go!
 
While preforming my inspection noted Arvilla truck unloading  noticed tank was leaking called their company rep and requested that they get tank repaired ASAP.
 
 
|-
 
|-
| 0923202239
+
| -987295990
| 2009-01-05
+
| 2006-12-14 0:00
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection revealed that pump was in operation during my inspection.
+
|  
Note: Housekeeping needed in tank area and stone is needed around unloading pad area to help minimize tracking mud out onto state route.
 
 
|-
 
|-
| 0939477225
+
| 00005604i4
| 2009-11-03
+
|  
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that pump was not in operation during my inspection,stopped at pumphouse and talked to well tender he stated that brine trucks have not been using facility recently,noted that tank area has been recently cleaned and facility appears to be in satisfactory condition this inspection.
+
|  
Note: Stone is needed on road to wellhead.
 
 
|-
 
|-
| 0963406981
+
| 0005377227
| 2004-11-09
+
| 2002-08-13
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
|  
(3)clean up needed in tank area
 
(11)housekeeping needed in unloading pad area.
 
 
|-
 
|-
| 0970119835
+
| 0005604i34
| 2015-01-10
+
| 2002-01-16
| Salt Water Injection Well
+
| Work Over Reconditioning
 
| No Violations
 
| No Violations
| On site to witness Formation cementing pump on tubing which was set on packer placed in between perforations and once rate was established decision was made that they would perform squeeze job tomorrow.
+
|  
 
|-
 
|-
| 0987295990
+
| 0005604i63
| 2006-12-14
+
| 2002-02-06
| Salt Water Injection Well
+
| Work Over Reconditioning
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in fair condition this inspection.
+
|  
Noted oil within tank area called company and requested that they clean up oil within tank area ASAP,told them that steam cleaning would need to be preformed within tank area to ensure of no pollution&contamination violations arose from free standing oil also cracks in concrete in need of repair! Small oil stain noted beside of unlading pad area in need of clean-up!
 
 
|-
 
|-
| 0996504738
+
| 000UIC1727
| 2018-05-17
+
| 1998-06-25
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Injection pump not in operation owner is currently having storage tanks cleaned out.
+
| 1501: 9-9-05 (10)  IDENTIFICATION
 
|-
 
|-
| 1015150122
+
| 001259i193
| 2015-07-14
+
| 2002-10-30
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that owner is still plumbing up new storage tanks and making preparations to start building new pump house facility
+
|  
 
|-
 
|-
| 1018136326
+
| 0048328763
| 2006-07-24
+
| 2005-01-06
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory this inspection.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
Noted: Pump was in operation on the day of my inspection,tank area in need of a good cleaning,cracks in concrete need to be resealed too ensure that no brine/oil can leach into the ground.
+
Noted:Three Key Energy tankers unloading brine during my inspection.
 +
(11) Housekeeping needed in unloading area,stone needed in driveway area.
 +
Tank area in need of a good steam cleaning!
 
|-
 
|-
| 1022095659
+
| 005604i102
| 2016-09-20
+
| 2002-03-19
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection today revealed that injection pump was in operation during my inspection and it was noted that one Evolution vacuum truck was unloading at the facility during my inspection.
+
|     Cleaning Tanks Preparing to place well in service.
 
|-
 
|-
| 1032171774
+
| 005604i169
| 2011-06-10
+
| 2002-04-26
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that owner is trying to remove old tanks and other waste from site,well is not in operation at this time due to fact of recent fire at tank facility.
+
|   Hooking up pumps.
 
|-
 
|-
| 1036095644
+
| 005604i206
| 2015-01-09
+
| 2002-05-09
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Onsite to witness bond logging of well to determine where possible leak is in wellbore and then perforate casing and tomorrow squeeze cement across defected zone.
+
|  
 
|-
 
|-
| 1036483126
+
| 005604i224
| 2010-06-17
+
| 2002-05-17
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Stopped and checked on service rig for update on getting packed and tubing out of well, rig crew stated that they have to mix more calcium chloride to kill well before removing packer and tubing.
+
|   1st. Test on pipeline failed due to a well head leak.  2d. Test failed due to pipeline leak.    New curb poured for loading pad.
 
|-
 
|-
| 1042501551
+
| 005604i225
| 2002-10-30
+
| 2002-05-21
| Annular Disposal
+
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Dike area needs house keeping done and unloading pad needs a good cleaning!
+
|     Pipeline from pump to well tested at 1510psi. For 30min. Pressure did not drop.    Test Approved.
Also need to change 1/4 valve on discharge side of well head.
 
 
|-
 
|-
| 1042657927
+
| 0085278170
| 2003-01-15
+
| 2002-05-06
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| [5]Tank area needs a good cleaning
+
| operator working on unloading pad. Carper well service is the owner!
 
|-
 
|-
| 1042658777
+
| 0087066765
| 2003-01-15
+
| 2014-11-03
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Tank area needs cleaned up.
+
| On site to witness rig operator pull tension on tubing string and then try and tighten up tubing head to stop small leak noted on previous inspection.
UNLOADING AREA NEEDS HOUSEKEEPING!
 
 
|-
 
|-
| 1044473445
+
| 0114208207
| 2003-02-05
+
| 2007-10-03
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Walked flow line appears to be O.K.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
(5) General house keeping in tank area.
+
Note: Owner is in process of cleaning out storage tanks called his office and left message that I will need run tickets to verify proper disposal of tank waste.
(11)House keeping on unloading pad.
 
 
|-
 
|-
| 1047389421
+
| 0149493778
| 2003-03-11
+
| 2015-12-16
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| well equalized called Carper Well to shut down well
+
| Inspection revealed that injection pump was in operation today and it was noted that two Ramco vacuum trucks were unloading at the facility on this day.
Called Tom Tomastik to get well shut down.
 
(11)housekeeping in unloading area
 
(3)tank area to be cleaned
 
 
|-
 
|-
| 1051625368
+
| 0174001850
| 2003-04-29
+
| 2017-04-28
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| On location to witness (Packer and tubing run in hole to 5220)due to supension order.4/30/03flush hole with30bbl fresh water and 5gal.inhibitor pressured tested well at 1230psi for 15min(pressure test passed)
+
| Inspection today revealed that injection pump was in operation during my inspection.
suggest removing old flowline going to tank facility.
+
 
 +
Note: Weedeating needed in area of wellhead and flowline area.
 
|-
 
|-
| 1052761827
+
| 0185563784
| 2003-05-12
+
| 2006-05-02
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted on the day of my inspection.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
(3)more clean-up needed in tank area
+
Note:Operator is trying to clean up tank area(stills has a way to go) but is putting some effort into getting facility up into 21st Century industry standards.
(11)housekeeping in unloading area
+
Walked flow line no leaks found.
needs to get service pit reclaimed
 
 
|-
 
|-
| 1054989774
+
| 0210366979
| 2011-04-01
+
| 2015-04-27
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| On site with well owner and insurance investigators to discuss recent fire at tank site, they were trying to determine cause of fire and estimate cost of replacing tanks and pump house and injection pump if owner decides to rebuild facility.
+
| Company owned  service rig on well cleaning out wellbore they were at 5251 with bit and hope to have interior of casing cleaned out by early next week.
 
|-
 
|-
| 1057420391
+
| 0214838369
| 2003-07-03
+
| 2014-01-24
 
| Salt Water Injection Well
 
| Salt Water Injection Well
| Violations Noted
+
| No Violations
| (3)oil tank in dike area has seepage on bottom seam,suggest replacing tank.
+
| Inspection revealed that well is still down waiting on owner to submit rebuild plan for facility.
(10)replace flowline to wellhead&remove all of old flowline
 
(11)housekeeping needed in unloading pad area.
 
Note:Contact inspector prior to putting well back into production after flowline is changed to pressure test new line.
 
 
|-
 
|-
| 1057751914
+
| 0216435958
| 2003-07-08
+
| 2015-04-15
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| preformed line pressure test on new flowline
+
| Inspection revealed that service rig was pulling tubing and milling tools from well bore to replace milling tool this one has stopped cutting up debris.
tested line at 1230 psi for 1hr. Test passed.
 
 
|-
 
|-
| 1060274630
+
| 0225655085
| 2003-08-04
+
| 2005-09-23
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted this inspection.
+
| No violations noted ,facility appers to be in satisfactory condition this inspection.
(3)suggest removing 100bbl.oil tank it appesrs to have small hole on bottom seam,also tank area needs a good steam cleaning.
+
Called well owner and stated that entire plumbing system at storage site is in need of being replaced due too fact that band clamps that they have in place are seeping,also noted that 210bbl storage tank is leaking from heater tube and is in need of being repaired or replaced,also told operator that entire tank area is in need of a good steam cleaning he stated he would start repairs 9/26/05 weather permitting.
(11)general housekeeping in unloading area needed.
 
 
|-
 
|-
| 1065265869
+
| 0250911662
| 2003-10-03
+
| 2017-02-08
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted,facility appears to be in good repair.
+
| On site to witness mini pressure test on annulus of tubing,injetion pup was in operation during my inspection.
(3)housekeeping needed in tank area
 
(11)housekeeping needed in unloading area
 
Restoration still needed in wellhead area!
 
 
|-
 
|-
| 1071295029
+
| 0259846312
| 2007-08-02
+
| 2019-02-12
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted ,facility appears to be in satisfactory condition this inspection.
+
| Inspection revealed that injection pump was not in operation during my inspection.
Noted that injection pump has been replaced since my last inspection.
+
 
Housekeeping is needed in unloading pad area it appears that customers tank valves leak during unloading process&also cleanup needed in tank area.
+
 
 +
Note: Inside of tank area is in need of a good cleaning noticed trace amount of sheen in water within containment area.
 
|-
 
|-
| 1071657513
+
| 0275102970
| 2003-12-16
+
| 2008-07-03
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted,facility appears to be in satisfactory condition.
+
| No violations noted, facility appears to be in satisfactory condition this inspection
(3)Housekeeping needed in tank area.
+
Note: Requested owner to replace 2 high pressure hose @wellhead the one in use is showing signs of  defects.
(11)Housekeeping needed in unloading area.
 
Conversation with Milard Carper stated he was going to change out 100bbl oil tank within dike next wee
 
 
|-
 
|-
| 1073727983
+
| 0286257119
| 2004-01-09
+
| 2017-05-24
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Facility appears to be in satisfactory condition on the day of my inspection.
+
| Inspection today revealed that injection pump to this well was in operatin today and it was noted that one company owned  tanker was unloading at the facility during my inspection.
(3)Housekeeping needed in tank area.
 
(11)Housekeeping needed in unloading pad area.
 
Note:100bbl oil tank still needs  to be replaced.
 
 
|-
 
|-
| 1078490394
+
| 0288665557
| 2004-03-04
+
| 2007-07-09
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted facility appears to be in satisfactory condition this inspection.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
(3)Clean up needed in tank area& old 100bbl tank that was removed from dike area needs to be hauled away.
+
Note: Pump was not in operation during my inspection, noted stainingon unloading pad apparently  truck had a bad leak in valve during unloading procedure.House keeping needed in tank area operator needs to clean out tanks to allow for more for more volume of brine .
(11)Clean up needed in unloading area
 
(4)area outside of dike needs to be addressed for cleanup.
 
 
|-
 
|-
| 1081207193
+
| 0345539737
| 2004-04-05
+
| 2007-02-06
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
 
| No violations noted facility appears to be in satisfactory condition this inspection.
 
| No violations noted facility appears to be in satisfactory condition this inspection.
(1)I.D. on tanks needs to be refreshed
+
Noted company owned tanker parked on unloading pad no truck attached,suggest placing tub under valve on tanker too catch salt water dripping from connections.
(3) tank area needs a good steam cleaning
+
|-
Triads water truck was unloading brine during my inspection UIC#310 driver Charlie Holly.
+
| 0371683144
 
+
| 2010-05-21
(11)housekeeping needed in unloading area
+
| Salt Water Injection Well
Note:old 100bbl tank needs to be removed from site!
+
| No Violations
 +
| Inspection revealed that pump was in operation during my inspection.
 +
Note: Area around wellhead is in need of restoration work preformed,area needs to be seeded&mulched to prevent eroision issues that might arise and road to wellhead is in need of stone.
 
|-
 
|-
| 1087052252
+
| 0386632174
| 2004-06-07
+
| 2012-11-07
| Salt Water Injection Well
+
| Production Wells
 
| No Violations
 
| No Violations
| No violations noted facility appears to be in satisfactory condition this inspection.
+
| My inspection today finds that the well has 100 psi. on the 4.5 casing, and 280 psi. on the 2.375 tubing.
(3)Steam cleaning needed in tank area.
 
(11)Housekeeping needed in unloading area.
 
 
|-
 
|-
| 1088984554
+
| 0387365330
| 2004-07-01
+
| 2008-06-02
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Facility appears to be in satisfactory condition this inspection.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
(1)Instructed operator to place proper I.D.at tank site,(3)Seggested to operator that clean is needed in tank area,told him failure to comply may result in suspension order.
+
Note: Pump was not operating during my inspection also walked flow line area to monitor area for potential leaks none found, tank area has been somewhat cleaned sealant in cracks needs to be replaced (not what your using at present date its not oil/brine compatible!!
RWS Trucking was unloading during my inspectionUIC#317
 
 
|-
 
|-
| 1091977487
+
| 0391155921
| 2004-08-04
+
| 2017-08-29
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted,facility appears to be in satisfactory this inspection.
+
| Inspection today indicated that injection pump was not in operation due to fact that Producers Services was on site performing 2000 gallon acid treatment on said well.
(6)Replace1/4valve on tubing side of wellhead to allow inspector to check pressure.
 
Customer ran storage tanks over suggested to well owner to steam clean tank area he agreed to do so.
 
 
|-
 
|-
| 1093169379
+
| 0395414581
| 2004-08-20
+
| 2015-10-01
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted,facility appears to be in satisfactory condition this inspection.
+
| Inspection on this day indicated that injection pump was not in operation during my inspection and it was noted that owner was having new lighting installed at the facility.
 
 
(6) 1/4 needle valve on tubing side of wellhead needs changed.
 
 
|-
 
|-
| 1100645896
+
| 0427080007
| 2015-05-20
+
| 2017-02-22
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Hole was cleaned out to 5501 and owner plans on logging well tomorrow and possibly start new tubing and packer in well next week.
+
| Inspection today revealed that injection pump was not in operation during my inspection.
 
|-
 
|-
| 1102177048
+
| 0429657617
| 2004-12-03
+
| 2017-08-24
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| Inspection today indicated that injection pump was in operation and operating at maximum allowable pressure and it was noted that two company owned vacuum trucks were unloading at the facility during my inspection.
Housekeeping needed in tank area.
 
Housekeeping needed in unloading pad area.
 
 
|-
 
|-
| 1111099522
+
| 0434747279
| 2005-03-14
+
| 2015-09-25
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| On site to do walkthrough with operator prior to placing well back into operation, all plumbing has been replaced and new 300 bbl. Tanks installed and new pump house has been constructed and once electrical work is completed owner will resume operations at this site.
(3)Tank area in need of a good steam cleaning.
 
Note:Walked flowline
 
 
|-
 
|-
| 1115482349
+
| 0435286527
| 2005-05-04
+
| 2010-02-02
 
| Salt Water Injection Well
 
| Salt Water Injection Well
| No Violations
+
| Violations Noted
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| Inspection revealed that well has equalizedcalled company and let them be aware of suspension order,call central office and requested order be issued for said well. Repair tubing /packer and properly perform required testing before placing well back into operation.
Well owner will need to preform clean-up within tank area(extensive steam cleaning).
+
 
Failure to comply may result in suspension order.
+
Failure to comply may result in bond forfeiture.
Energy Contractors vac truck on site but not driver could be located.
 
 
|-
 
|-
| 1129249585
+
| 0438810527
| 2005-10-07
+
| 2015-02-02
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| Inspection revealed that company owned service rig was pulling tubing from well and changing out bit and once they get cement retainer drilled up and they get below perforations they will pressure test casing for integrity.
Noted housekeeping has been preformed in tank area also new plumbing of piping system in place,cracks in concrete in need of being repaired.
 
Suggest cleaning of inside of storage tanks to allow for more volume of brine storage!
 
 
|-
 
|-
| 1131718009
+
| 0440372304
| 2005-11-07
+
| 2015-09-14
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| Inspection on this day indicated that owner is nearly complete with rebuilding of facility and we pressure tested flow line to wellhead at 1400 psi with no pressure loss and I reminded owner that new identification needed to be posted on tanks and also wellhead.
Noted: High pressure on annulus of tubing well operator stated that he liked to maintain high annulus pressure too help relieve pulsating tubing.
 
 
|-
 
|-
| 1136321763
+
| 0451380060
| 2006-01-03
+
| 2007-06-05
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactiry condition this inspection.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
Pump not running during my inspection,housekeeping needed in tank area when weather permits.
+
Pump was not in operation during my inspection,called well owner and suggested that they have well tender weedeat path to wellhead and steamclean tank area ASAP.
 
|-
 
|-
| 1142032665
+
| 0458578328
| 2006-03-08
+
| 2016-05-31
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| Inspection revealed that injection pump was in operation today.
Housekeeping needed in tank area, when weather permits steam cleaning needed in said area.
 
 
 
Suggest having fire extinguishers checked and refill if needed also check first aid kit for ample supplies.
 
 
|-
 
|-
| 1149347793
+
| 0479689203
| 2006-06-01
+
| 2015-11-17
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| Inspection revealed that injection pump was in operation during our inspection today.
Suggest placing stone on road to wellhead and housekeeping in tank area!
 
 
|-
 
|-
| 1155677242
+
| 0480021501
| 2006-08-15
+
| 2015-01-05
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| Inspection on this day revealed that company owned service rig was running a test packer in well to locate possible hole in casing and once they pinpoint it they will perform cement squeeze job to repair casing.
Noted that right away for flow line has been mowed to allow inspector to walkflowline area,cracks in concrete in tank area still need to be repaired.
 
 
|-
 
|-
| 1158401092
+
| 0495884058
| 2006-09-14
+
| 2016-09-07
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| On site to witness mini pressure test on annulus of tubing they applied 500 psi of pressure and we monitored it for 15 minutes with no decline in pressure.
Note:Pump note in operation today noted that seals were out of transfer pump and hoses were leaking inside of pump house called well owner Milard Carper and requested that he replace faulty hoses and repair seal on transfer pump or replace entire pump,also noted that steam cleaning has not been preformed in tank area that was suggested on previous inspection.
 
 
|-
 
|-
| 1160128383
+
| 0524935433
| 2006-10-04
+
| 2008-12-04
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection, walked flow line too monitor for possible leaks none found) also noted that housekeeping is suggested in tank area cracks in concrete in need of being resealed to prevent escape of brine water into fresh water strata.
+
| Inspection revealed that pump was not in operation during my inspection.
 +
Note:As weather permits housekeeping is needed  in tank area also noted damp conditions around cleanout plate on several 210 bbl tanks suggest empty tanks and reseal cover plates.
 
|-
 
|-
| 1164361592
+
| 0528958761
| 2006-11-20
+
| 2018-04-02
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted facility appears to be in satisfactory condition this inspection.
+
| Inspection revealed that there was no activity at the site during my inspection.
Pump not running today,operator will need to perform housekeeping in tank area,small cracks in concrete in tank area still needs to be sealed up!weed eating on path of flow line needs preformed before weather gets too bad.
 
 
|-
 
|-
| 1173468844
+
| 0543784100
| 2007-03-09
+
| 2009-05-12
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted facility appears to be in satisfactory condition this inspection,pump was not operating during my inspection Energy Contractors tanker was unloading at facility talked to driver and suggested he replace valve on truck before returning to this facility he stated he would tell supervisor when he returned truck to Weston WVA.Also called and talked to well owner concerning cleanup needed within tank area he stated that a valve had froze up and busted allowing small amount of oil to seep out within tank area.
+
| Inspection this day found Producers Service Co. acidizing injection well. Used 2000 gal. Of 15% acid and well taking it fairly easily.
 
|-
 
|-
| 1175641067
+
| 0557678394
| 2007-04-02
+
| 2014-10-30
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No vioolations noted facility appears to be in satisfactory condition this inspection.
+
| Inspection revealed that concrete has been put in place and workers are proceeding along with getting well back into operation.
Noted that well owner is attempting too repair cracks in concrete in tank area still has quite a bit of work to do before all cracks are sealed,suggest replacing 1/4 valves on wellhead the ones in place are getting hard to work!,stone is needed on road to wellhead.
 
 
|-
 
|-
| 1189721624
+
| 0561435102
| 2007-09-10
+
| 2015-04-06
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| Stopped by service rig for update and they have retrieved bridge plug and now they are making site ready to go back in well and start drilling out cement retainer.
Note: Pump was not operating during my inspectin,walked flow line area to monitor for leaks (none found) owner needs to clean up within tank area,noted possible seepage on two 210 bbl tanks will monitor as needed if  seepage worsens will request owner remove&replace tanks.
+
Note: Stopped at recently rebuilt containment area and tested water for chlorides none were detected after running quantab strip test.
 
|-
 
|-
| 1194259204
+
| 0572190922
| 2012-11-07
+
| 2010-12-09
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that facility is still down awaiting repairs to storage facility and pump house replacement and electrical services restored at site.
+
| Inspection revealed that injection pump was not in operation during my inspection.
 +
Note: Platform needs to be constructed at well head so inspector can properly remove gauge and monitor pressures at wellhead. Also noted that all storage tanks have been cleaned out and resealed and partially replumbed.
 
|-
 
|-
| 1194388911
+
| 0585855735
| 2007-11-02
+
| 2015-04-17
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| Inspection revealed that power swivel broke down and owner is currently making repairs on swivel and they will resume workover procedure within the next couple of days.
Note: Pump was in operation during my inspection, also noted that well owner is in process of cleaning out storage tanks,noted waste container placed on unloading pad it appeared that operator has been placing sludge in container and shiping it to a approved EPA landfill.
 
 
|-
 
|-
| 1195731531
+
| 0599281069
| 2007-11-20
+
| 2011-03-26
| Salt Water Injection Well
+
| Annular Disposal
 
| No Violations
 
| No Violations
| On site to witness clean-up efforts made by well owner,crew was steam cleaning tank area as suggested by inspector too help eliminate foul odor at unloading site,monitored H2S meter near tanks detected 6ppm during inspection,pump was in operation during inspection.
+
| Call from EMS in Noble Co. regarding a fire at disposal well south of Belle Valley. Responded to call, observed fire and the extingushing of it - took many pictures.
 
|-
 
|-
| 1195843018
+
| 0602395613
| 2007-11-21
+
| 2003-09-04
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Complaint made by Susan@AbabbellasRestaurant of foul odor wants something doneabout it,told her that smell would disapate with timeran monitor around location no H2S detected,crew was on site steam cleaning tank area trying to avoid any more complaints from local citizens,suggested they have local refuge hauler come and empty dumpster(old filters and filter sacks were in it and odor was detected.
+
| No violations noted,facility appears to be in good condition.
 +
(3)oil tank still needs replaced
 +
(11)housekeeping needed in unloading area
 +
lease road to wellhead needs dressed up
 +
Suggest replacing hoses at unloading site (camlock ends are getting worn)
 +
Note:Walked flowline.
 
|-
 
|-
| 1196722381
+
| 0636816591
| 2007-12-03
+
| 2018-12-27
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| Inspection today revealed that injection pump was in operation and it was noted that one company owned vacuum truck was offloading at the facility during my inspection.
Note: Pump was in operation during my inspection, walked flow line area to monitor area for potential leaks( none found),small trace of H2S odor detected on south side of storage tank area,storage tanks on south side of facility needs to be emptied and tanks properly cleaned!!!!!.
 
 
|-
 
|-
| 1199308204
+
| 0675004728
| 2008-01-02
+
| 2008-05-07
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| No violations noted, facility appears to be in satisfactor condition this inspection.
Note: Pump was not in operation during my inspection, well tender stated he had just shut pump down prior to my arrival.
+
Note: Tank area is in need of a severe steam cleaning and trash dumpster is in need of repacement it has hole in bottom seeping residue from filter changes,also 2 nipple on elbow is in need of thread tape replacement@ wellhead.
 
|-
 
|-
| 1202476629
+
| 0678997720
| 2007-01-02
+
| 2019-04-01
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted facility appears to be in satisfactory condition this inspection.
+
| Inspection today indicated that injection pump was in operation during my inspection.
Pump was not running during my inspection noted operator has cleaned up oil within tank area since my last inspection but cracks in concrete still needs to be sealed.
+
 
 +
Noted one company owned vacuum truck on site during my inspection.
 
|-
 
|-
| 1202769405
+
| 0679021003
| 2008-02-11
+
| 2015-04-02
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| Service rig still on site attempting to remove bridge plug that was set in well bore they have gotten a hold of it and are coming out of the hole with it today.
Note: Clean-up needed in tank area,it appears that operator ran oil tank over and it is a mess within tank area, suggest that owner steam tank area as soon as weather permits also have well operator keep a better eye on tanks and not let them run over!!!!!!!.also clean up is needed in wellhead area it appears that tubing head packing has leaked a little since my last inspection.
 
 
|-
 
|-
| 1204580759
+
| 0708379192
| 2008-03-03
+
| 2015-02-04
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| On site to witness pressure test of 4.5 casing they pressured up to 1250 psi and we monitored pressure for 15 minutes with a 10# loss(TEST PASSED).
Note: Cleanup in tank area needed,tanks need cleaned and steamed,pump was in operation during my inspection also walked flow line area to monitor for potential leaks none found).
 
 
|-
 
|-
| 1207662360
+
| 0716431656
| 2012-02-10
+
| 2014-10-29
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| On site to met with landowner and well operator to discuss issues with getting well back into operation it was agreed upon that dike walls will be replaced and pump location be mover outside of tank area and road to wellhead will be stoned before going into operation and fire suppression system be in place also.
+
| On site to witness crew place stone on exterior of containment wall to help strengthen it and on this day they formed up area for the new pump house and trash bin area and if weather permits they will place concrete tomorrow.
 
|-
 
|-
| 1211473851
+
| 0757321958
| 2015-05-07
+
| 2015-05-21
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that company owned service rig on site preparing to trip out tubing and mill tomorrow.
+
| Timco on site to log well and possibly reperforate casing.
 
|-
 
|-
| 1217350529
+
| 0759916444
| 2003-04-14
+
| 2013-08-20
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Stopped by service rig for update they were getting ready to pull defected tubing out of hole.
+
| My inspection today revealed that the injection well is still shut down awaiting the owner to rebuild the tank facility and pump house, they had fire at facility a couple years ago.
 +
 
 
|-
 
|-
| 1217886805
+
| 0766214683
| 2008-08-04
+
| 2016-05-18
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| Inspection today revealed that injection pump was in operation and it was noted that one RAMCO bottle trucks was on site unloading during my inspection,
Note: Pump was in operation during my inspection, walked flow line area to monitor area for potential leaks none found),also noted three company owned vac trucks unloading at facility during my inspection ,talked to well tender  concerning leaking fittings on unloading plumbing he stated he would have bad fittings replaced by days end.
 
 
|-
 
|-
| 1220729098
+
| 0785092645
| 2008-09-04
+
| 2015-01-30
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Pump not in operation today,unloading pad is in need of a good cleaning and tank area alsois in needof a steam cleaning.
+
| Stopped by service rig for update they were still drilling cement retainer out  and operator stated that he could be ready to pressure test casing integrity tomorrow if they get hole cleaned up.
 
|-
 
|-
| 1226417143
+
| 0788205253
| 2008-11-10
+
| 2015-03-31
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that well was not in operation during my inspection,after talking to well tender stating that well has been down for pump repair,noted that H&L Oilfield Services vac truck was unloading at site during my inspection,told well tender thhat cleanup in tank area was needed he stated that he would let well owner know that work is neededd in tank area.
+
| Company owned rig milling on bridge plug they hope to pull it from well later this week.
 
|-
 
|-
| 1230648854
+
| 0795119875
| 2011-04-28
+
| 2008-10-02
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump has been removed from site of recent fire at facility,adjacient land owner called and voiced concerns if owner was planning on reopening well for commercial use.
+
| Inspection revealed that well was not in operation during my inspection, well tender was replacing plumbing on tubing head 2 high pressure elbow was replaced and other assorted fittings also, tank area is in need of a good cleaning while the weather is favorable.
 
|-
 
|-
| 1236212068
+
| 0809104420
| 2009-03-04
+
| 2018-10-05
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was not in operation today,welll tender stated that mainitence work in pump house was to be preformed today,called owner and discussed getting stone for facility and getting tank area steamed cleaned in the near future.
+
| On site to witness acid treatment job 2000 gallon of 28% HCL was pumped and ISIP was noted at 1107 and after 10 minutes it was noted at 896 psi  Producers rigged down and job was deemed complete.
 
|-
 
|-
| 1250073390
+
| 0844377490
| 2009-08-11
+
| 2013-12-13
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that well was not in operation today,instructed well tender to install new 1/4 needle valve on tubing old one is showing signs of leakage.Also inquired about getting belt guard installed on injection pump pulley,in its present state ther is a safety  issue.
+
| Inspection revealed that well is still down waiting on owner to submit rebuild plan to division.
 
|-
 
|-
| 1252803534
+
| 0855505376
| 2014-10-27
+
| 2007-11-16
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Stopped by well site to check on work crew that is making upgrades to facility.
+
| Complaint called in from OHIO EPA(Dennis Deavers) of strong odor of sulfur smell near tank site,upon inspecting site found that operator had unloaded tanker truck prior to my inspection apparently source of smell derived from water source from unknown source in adjoining state, contacted well owner Millard Carper and discussed issues at well site, received several complaints from local citizens about odor told them smell would dissipate in time.
 
|-
 
|-
| 1254363886
+
| 0874994452
| 2010-12-29
+
| 2005-06-01
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspected site along with supervisor and inspection revealed that pump was in operation today.
+
| No violations noted facility appears to be in satisfactory condition this inspection.
Note: Platform at wellhead is needed so inspector doesnt have to climb on tubing head to place gauge on and more cleanup around wellhead is needed there is still old pit liner and lumber that needs to be removed from site and as weather permits vegetation needs to be established in area of old working pit.
+
Noted that partial cleanup in tank area has been preformed lots more to go!
 +
While preforming my inspection noted Arvilla truck unloading  noticed tank was leaking called their company rep and requested that they get tank repaired ASAP.
 
|-
 
|-
| 1257841499
+
| 0923202239
| 2004-02-10
+
| 2009-01-05
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted facility appears to be in good repair.
+
| Inspection revealed that pump was in operation during my inspection.
(1)tank I.D.needs refreshed
+
Note: Housekeeping needed in tank area and stone is needed around unloading pad area to help minimize tracking mud out onto state route.
(3)extensive cleaning needed in tank area
 
(11)housekeeping needed in unloading pad area
 
Note:old 100bbl oil tank needs removed from site!
 
 
|-
 
|-
| 1265755723
+
| 0939477225
| 2010-02-09
+
| 2009-11-03
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Well down for repair, injection pressure and annulus pressure equalized .Talked to well owner Millard Carper and suggested that he bleed off pressure on backside of tubing then reapply pressure and I would monitor it for compliance.
+
| Inspection revealed that pump was not in operation during my inspection,stopped at pumphouse and talked to well tender he stated that brine trucks have not been using facility recently,noted that tank area has been recently cleaned and facility appears to be in satisfactory condition this inspection.
 +
Note: Stone is needed on road to wellhead.
 
|-
 
|-
| 1268771824
+
| 0963406981
| 2010-03-16
+
| 2004-11-09
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Stopped by well site to check on rig ,they were mixing Calcium Chloride to weight up water to kill well so they could pull tubing and then go in well to drill up cement retainer and then run new packer assembly  in well and if all goes good place well back into operation.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
 +
(3)clean up needed in tank area
 +
(11)housekeeping needed in unloading pad area.
 
|-
 
|-
| 1269124297
+
| 0970119835
| 2010-03-19
+
| 2015-01-10
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Stopped by service rig for update,rig crew was rigging up power swivel and mud pump in preparation to drill out cement retainer.3/20/2010 Rig operator called and stated they had drilled up retainer and possibly will be ready to run packer and tubing in well 3/22/2010.
+
| On site to witness Formation cementing pump on tubing which was set on packer placed in between perforations and once rate was established decision was made that they would perform squeeze job tomorrow.
 
|-
 
|-
| 1269296520
+
| 0987295990
| 2010-03-22
+
| 2006-12-14
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| On site to witness rig operator start new Patriot Packer in hole, will continue to run the rest of tubing 3/23/10 and pressure test annulus of tubing if Packer passes required testing.
+
| No violations noted, facility appears to be in fair condition this inspection.
 +
Noted oil within tank area called company and requested that they clean up oil within tank area ASAP,told them that steam cleaning would need to be preformed within tank area to ensure of no pollution&contamination violations arose from free standing oil also cracks in concrete in need of repair! Small oil stain noted beside of unlading pad area in need of clean-up!
 
|-
 
|-
| 1269389403
+
| 0996504738
| 2010-03-23
+
| 2018-05-17
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| On site to witness rig crew run tubing and set packer@5165 informed owner that he would be required to request variance on packer setting depth because they are not within 100 of top perf,called Central Office and talked to UIC supervisor regarding setting depth of packer.
+
| Injection pump not in operation owner is currently having storage tanks cleaned out.
Note: Packer is equipped with down hole shut off valve and setting depth is 5165 Patriot model T 607.
 
 
|-
 
|-
| 1271368944
+
| 1015150122
| 2010-04-13
+
| 2015-07-14
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was not in operation during my inspection.
+
| Inspection revealed that owner is still plumbing up new storage tanks and making preparations to start building new pump house facility
Note: Called company in reguards too restoration work needed at site,area needs to be seeded and mulched to help prevent erosion issues at site and old plastic pit liner needs to be properly disposed of.
 
 
|-
 
|-
| 1275050552
+
| 1018136326
| 2017-12-28
+
| 2006-07-24
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was in operation during my inspection and operating at maximum allowable pressure and in conversation with operator stating that they were receiving flowback water at this time.
+
| No violations noted, facility appears to be in satisfactory this inspection.
 +
Noted: Pump was in operation on the day of my inspection,tank area in need of a good cleaning,cracks in concrete need to be resealed too ensure that no brine/oil can leach into the ground.
 
|-
 
|-
| 1275517476
+
| 1022095659
| 2010-06-02
+
| 2016-09-20
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that well has equalized, called company and requested that they repair well, they stated that they would have service rig on well within the next couple days and they would pull tubing and packer and inspect element on packer and check for possible hole in tubing.
+
| Inspection today revealed that injection pump was in operation during my inspection and it was noted that one Evolution vacuum truck was unloading at the facility during my inspection.
 
|-
 
|-
| 1276901772
+
| 1032171774
| 2010-06-18
+
| 2011-06-10
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Stopped by service rig for update they were attempting to kill well in preparation to pull tubing and packer, rig operator called and stated they had removed tubing and packer from well and would attach swedge and valve to casing and shut it in for the weekend .
+
| Inspection revealed that owner is trying to remove old tanks and other waste from site,well is not in operation at this time due to fact of recent fire at tank facility.
 
|-
 
|-
| 1277672162
+
| 1036095644
| 2010-06-26
+
| 2015-01-09
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| On site at request of well owner too witness running of tubing and packer in hole to test for integrity of casing and tubing, arrived on site and witnessed rig operator run casing scrapper in hole to remove scale and any other obstruction that might hinder setting of packer element. Operator was unable to start running packer and tubing due to fact well was still flowing back told them to get well killed and once they reached that point call Inspector so he can come to site and witness running of tubing and packer in well.
+
| Onsite to witness bond logging of well to determine where possible leak is in wellbore and then perforate casing and tomorrow squeeze cement across defected zone.
 
|-
 
|-
| 1277672809
+
| 1036483126
| 2010-06-27
+
| 2010-06-17
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Rig operator called and stated they were ready to run tubing and packer into well,upon arriving on site it was determined that well was not static decision was made to mix more kill fluid and try again tomorrow.
+
| Stopped and checked on service rig for update on getting packed and tubing out of well, rig crew stated that they have to mix more calcium chloride to kill well before removing packer and tubing.
 
|-
 
|-
| 1277766028
+
| 1042501551
| 2010-06-28
+
| 2002-10-30
| Salt Water Injection Well
+
| Annular Disposal
 
| No Violations
 
| No Violations
| Onsite to witness operator run tubing and packer in well,setting depth was 5198.30 pressured up on annulus to 1270 psi and monitored pressure for 15 min pressure declined to 980 psi at end of test (TEST FAILED) will attempt to move packer up hole 8 tomorrow and retest.
+
| Dike area needs house keeping done and unloading pad needs a good cleaning!
 +
Also need to change 1/4 valve on discharge side of well head.
 
|-
 
|-
| 1278154931
+
| 1042657927
| 2010-07-02
+
| 2003-01-15
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Stopped by service rig for update on trying to repair casing they think that 4.5 possibly has hole in it above cement top is estimated to be@approximatly 900 according to E-logs at site, will continue to monitor well site for compliance.
+
| [5]Tank area needs a good cleaning
 
|-
 
|-
| 1279309367
+
| 1042658777
| 2010-07-13
+
| 2003-01-15
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| On site to witness rig operator run 1.5 tubing down backside of production casing and tag cement top and then pump cement slurry in casing to seal off any potential leakage in 4.5 casing, will retest annulus of tubing string and packer integrity in near future.
+
| Tank area needs cleaned up.
 +
UNLOADING AREA NEEDS HOUSEKEEPING!
 
|-
 
|-
| 1283288298
+
| 1044473445
| 2010-08-31
+
| 2003-02-05
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Stopped but service rig for update on running packer and tubing back in well too test for casing integrity and to flush annulus of tubing and add fresh water and inhibitor to backside of tubing if testing indicates that we have good integrity.
+
| Walked flow line appears to be O.K.
Note: Owner  will possibly want to set packer at higher depth in hole, suspects faulty casing at old setting depth.
+
(5) General house keeping in tank area.
 +
(11)House keeping on unloading pad.
 
|-
 
|-
| 1284161485
+
| 1047389421
| 2010-09-10
+
| 2003-03-11
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that well is not in operation at this time, on site to witness rig crew mix kill water and then packer rep attempted to release packer and set at higher depth, packer was released and we moved packer up hole one joint at a time and attempted pressure test, once we reached 5006 and packer would not set decision was made to pull packer from well and have packer rep rebuild it and we will run it back in hole as soon as it is delivered back to well site.
+
| well equalized called Carper Well to shut down well
 +
Called Tom Tomastik to get well shut down.
 +
(11)housekeeping in unloading area
 +
(3)tank area to be cleaned
 
|-
 
|-
| 1285196310
+
| 1051625368
| 2010-09-22
+
| 2003-04-29
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Stopped by well site to check on service rig crew, they were mixing calcium chloride in attempt too kill well and possibly start new packer in hole.
+
| On location to witness (Packer and tubing run in hole to 5220)due to supension order.4/30/03flush hole with30bbl fresh water and 5gal.inhibitor pressured tested well at 1230psi for 15min(pressure test passed)
 +
suggest removing old flowline going to tank facility.
 
|-
 
|-
| 1293304785
+
| 1052761827
| 2011-05-09
+
| 2003-05-12
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Stopped by site to check on fluid level in dike area there was approximatly 6 of fluid in dike with very low brine content it will need to be removed from dike and hauled to another disposal well.
+
| No violations noted on the day of my inspection.
 +
(3)more clean-up needed in tank area
 +
(11)housekeeping in unloading area
 +
needs to get service pit reclaimed
 
|-
 
|-
| 1296272525
+
| 1054989774
| 2010-03-30
+
| 2011-04-01
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Stopped by well to check on injection pump for leakage after start up at facility,none detected.
+
| On site with well owner and insurance investigators to discuss recent fire at tank site, they were trying to determine cause of fire and estimate cost of replacing tanks and pump house and injection pump if owner decides to rebuild facility.
Note: Pit at wellhead needs to be emptied ASAP and area restored and seeded and mulched to help prevent erosion at wellsite.
 
 
|-
 
|-
| 1298254422
+
| 1057420391
| 2013-09-13
+
| 2003-07-03
 
| Salt Water Injection Well
 
| Salt Water Injection Well
| No Violations
+
| Violations Noted
| Inspection revealed that well is still down awaiting on work over plan to be approved by Central Office.
+
| (3)oil tank in dike area has seepage on bottom seam,suggest replacing tank.
|-
+
(10)replace flowline to wellhead&remove all of old flowline
| 1301171506
+
(11)housekeeping needed in unloading pad area.
| 2011-03-26
+
Note:Contact inspector prior to putting well back into production after flowline is changed to pressure test new line.
| Salt Water Injection Well
 
| No Violations
 
| Received call from Com Center of tank fire south of Belle Valley on state route 821,investigated site and found that fire started in pump house area and then spread to tank area and all tanks and pump house were a total loss, two 210 bbl tanks erupted and landed on adjacent building and one landed in parking area, there was 6 fire departments responded and one officer from parks and one officer from wildlife were also on scene and three Noble county law enforcement officers were also present.
 
Once fire was put out and site evaluated it was determined that no brine/oil had escaped from dike area and I told well owner to remove all fluids from dike area and empty all remaining tanks at site and haul to another disposal well, will check on situation tomorrow.
 
 
|-
 
|-
| 1301240842
+
| 1057751914
| 2011-03-27
+
| 2003-07-08
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspected site to check on compliance of inspectors directions of removing brine from dike area and too also check on any potential tank leakage none noted and all but two storage tanks have been emptied and they will be hauled out tomorrow and taken to another disposal well will check back in on site at later date to check up on clean up detail.
+
| preformed line pressure test on new flowline
 +
tested line at 1230 psi for 1hr. Test passed.
 
|-
 
|-
| 1301519834
+
| 1060274630
| 2011-03-30
+
| 2003-08-04
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Visited site along with supervisor and we discussed events of recent fire at site and it was determined that if owner decides to rebuild facility concrete dike will need to be replaced not repaired.
+
| No violations noted this inspection.
 +
(3)suggest removing 100bbl.oil tank it appesrs to have small hole on bottom seam,also tank area needs a good steam cleaning.
 +
(11)general housekeeping in unloading area needed.
 
|-
 
|-
| 1304716629
+
| 1065265869
| 2011-05-05
+
| 2003-10-03
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that well is not in operation due to fact of recent fire destroying injection pump and tank facility and dike area.
+
| No violations noted,facility appears to be in good repair.
 +
(3)housekeeping needed in tank area
 +
(11)housekeeping needed in unloading area
 +
Restoration still needed in wellhead area!
 
|-
 
|-
| 1305694384
+
| 1071295029
| 2006-04-04
+
| 2007-08-02
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| No violations noted ,facility appears to be in satisfactory condition this inspection.
Note:Tank area in need of severe cleaning as soon as weather permits,also stone needed on lease road to wellhead,weedeating needed in area of flow line to wellhead.
+
Noted that injection pump has been replaced since my last inspection.
 +
Housekeeping is needed in unloading pad area it appears that customers tank valves leak during unloading process&also cleanup needed in tank area.
 
|-
 
|-
| 1310603768
+
| 1071657513
| 2011-07-13
+
| 2003-12-16
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that well is still down for repair, several storage tanks have been removed from dike area there is three remaining tanks within dike 1-210 bbl and 2-100 bbl tanks it appears that owner is planning on cleaning up area within dike and possibly rebuilding injection facility.
+
| No violations noted,facility appears to be in satisfactory condition.
 +
(3)Housekeeping needed in tank area.
 +
(11)Housekeeping needed in unloading area.
 +
Conversation with Milard Carper stated he was going to change out 100bbl oil tank within dike next wee
 
|-
 
|-
| 1314994147
+
| 1073727983
| 2011-08-31
+
| 2004-01-09
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that well is out of service due to fact that tank site and pump house burnt up in recent fire at facility, water within tank area needs to be removed and weeds going to wellhead need to be cut and if well is going to be repaired unloading pad and tank site will need to be moved to a new location.
+
| Facility appears to be in satisfactory condition on the day of my inspection.
 +
(3)Housekeeping needed in tank area.
 +
(11)Housekeeping needed in unloading pad area.
 +
Note:100bbl oil tank still needs  to be replaced.
 
|-
 
|-
| 1316122404
+
| 1078490394
| 2011-09-14
+
| 2004-03-04
 
| Salt Water Injection Well
 
| Salt Water Injection Well
| Violations Noted
+
| No Violations
| Inspection revealed that well is not in operation and has been idle for several months, tank area has water build up and needs to be hauled to another disposal facility.
+
| No violations noted facility appears to be in satisfactory condition this inspection.
Plug or put well back into operation after relocating unloading pad and tank and pump house areas.
+
(3)Clean up needed in tank area& old 100bbl tank that was removed from dike area needs to be hauled away.
Failure to comply may result in bond forfeiture.
+
(11)Clean up needed in unloading area
 +
(4)area outside of dike needs to be addressed for cleanup.
 
|-
 
|-
| 1323379584
+
| 1081207193
| 2011-12-08
+
| 2004-04-05
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that there has been no change in status of well it still remains idle and owner has made no attempts to place well back into operation.
+
| No violations noted facility appears to be in satisfactory condition this inspection.
 +
(1)I.D. on tanks needs to be refreshed
 +
(3) tank area needs a good steam cleaning
 +
Triads water truck was unloading brine during my inspection UIC#310 driver Charlie Holly.
 +
 
 +
(11)housekeeping needed in unloading area
 +
Note:old 100bbl tank needs to be removed from site!
 
|-
 
|-
| 1332629825
+
| 1087052252
| 2012-03-23
+
| 2004-06-07
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that well is not in operation at this time, owner is trying to make a deal with another operator to take over well and place back into operation.
+
| No violations noted facility appears to be in satisfactory condition this inspection.
 +
(3)Steam cleaning needed in tank area.
 +
(11)Housekeeping needed in unloading area.
 
|-
 
|-
| 1333834625
+
| 1088984554
| 2012-04-06
+
| 2004-07-01
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Well is down for repair and replacement of tanks and injection pump and upgrades being made too facility.
+
| Facility appears to be in satisfactory condition this inspection.
 +
(1)Instructed operator to place proper I.D.at tank site,(3)Seggested to operator that clean is needed in tank area,told him failure to comply may result in suspension order.
 +
RWS Trucking was unloading during my inspectionUIC#317
 
|-
 
|-
| 1339110616
+
| 1091977487
| 2012-06-04
+
| 2004-08-04
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that well is still down for repair, it was noted that all old storage tanks have been removed from site and it was also noted that vault in unloading pad has been emptied.
+
| No violations noted,facility appears to be in satisfactory this inspection.
 +
(6)Replace1/4valve on tubing side of wellhead to allow inspector to check pressure.
 +
Customer ran storage tanks over suggested to well owner to steam clean tank area he agreed to do so.
 
|-
 
|-
| 1351488117
+
| 1093169379
| 2004-05-10
+
| 2004-08-20
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
 
| No violations noted,facility appears to be in satisfactory condition this inspection.
 
| No violations noted,facility appears to be in satisfactory condition this inspection.
(3)housekeeping needed in tank area(steamed cleaned)
+
 
(11)housekeeping needed in unloading area.
+
(6) 1/4 needle valve on tubing side of wellhead needs changed.
 
|-
 
|-
| 1363030194
+
| 1100645896
| 2013-03-11
+
| 2015-05-20
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection well is still down awaiting on owner to rebuild tank facility and pump house, they had fire at facility a couple years ago.
+
| Hole was cleaned out to 5501 and owner plans on logging well tomorrow and possibly start new tubing and packer in well next week.
 
 
 
|-
 
|-
| 1376609958
+
| 1102177048
| 2018-05-14
+
| 2004-12-03
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was not in operation today due too fact they are preparing to have all of there storage tanks cleaned out.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
 +
Housekeeping needed in tank area.
 +
Housekeeping needed in unloading pad area.
 
|-
 
|-
| 1384500063
+
| 1111099522
| 2009-02-12
+
| 2005-03-14
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was in operation during my inspection, noted that storage tanks had run over all spillage was contained within dike ,talked to well tender and suggested that they have tanks cleaned as soon as weather permits.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
Note: STONE IS NEEDED AROUND FACILITY TO HELP KEEP MUD FROM ENTERING HIGHWAY!!!!!!
+
(3)Tank area in need of a good steam cleaning.
 +
Note:Walked flowline
 
|-
 
|-
| 1389820083
+
| 1115482349
| 2014-01-15
+
| 2005-05-04
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that well is still down waiting on plan to be submitted to rebuild facility to current industry standards.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
 +
Well owner will need to preform clean-up within tank area(extensive steam cleaning).
 +
Failure to comply may result in suspension order.
 +
Energy Contractors vac truck on site but not driver could be located.
 
|-
 
|-
| 1398286402
+
| 1129249585
| 2014-04-23
+
| 2005-10-07
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that well is still down awaiting on rebuild plan to be submitted to Central Office.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
 
+
Noted housekeeping has been preformed in tank area also new plumbing of piping system in place,cracks in concrete in need of being repaired.
Note: Called company and requested that they have positive pressure applied to annulus of tubing.
+
Suggest cleaning of inside of storage tanks to allow for more volume of brine storage!
 
|-
 
|-
| 1400017013
+
| 1131718009
| 2014-05-13
+
| 2005-11-07
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that well is still down waiting on owner to rebuild facility.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
Note: On site along with Ryan Carper to pressure test annulus of tubing he applied 1000# of pressure and we monitored it for 15+ minutes with no decline in pressure.
+
Noted: High pressure on annulus of tubing well operator stated that he liked to maintain high annulus pressure too help relieve pulsating tubing.
 
|-
 
|-
| 1407867614
+
| 1136321763
| 2014-08-12
+
| 2006-01-03
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that well is still down waiting on owner to repair well or sell it to a responsible owner.
+
| No violations noted, facility appears to be in satisfactiry condition this inspection.
 +
Pump not running during my inspection,housekeeping needed in tank area when weather permits.
 
|-
 
|-
| 1409215036
+
| 1142032665
| 2016-07-21
+
| 2006-03-08
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was not in operation during my inspection.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
 +
Housekeeping needed in tank area, when weather permits steam cleaning needed in said area.
 +
 
 +
Suggest having fire extinguishers checked and refill if needed also check first aid kit for ample supplies.
 
|-
 
|-
| 1414002865
+
| 114208207
| 2014-10-22
+
| 2007-10-3 0:00:
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection revealed that Crescent Supply crew is on site placing felt padding in dike area and once it is in place they will place 60 mil liner in place and spot storage tanks after that point.
+
|  
 
|-
 
|-
| 1415357458
+
| 1149347793
| 2014-11-05
+
| 2006-06-01
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| On site to witness rig crew pull tension on tubing string and then tighten up tubing head to try and fix small leak noted on it on my last inspection after they tightened it up they applied pressure and we noticed another small leak we will retighten it later this week and retest it.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
 +
Suggest placing stone on road to wellhead and housekeeping in tank area!
 
|-
 
|-
| 1415472044
+
| 1155677242
| 2014-11-07
+
| 2006-08-15
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| On site to witness owner attempt to pressure test annulus of tubing after they made repairs to tubing head they pressured up to1275 and we monitored pressure for 15 minutes and at the end of test period pressure had dropped too 900 psi and test failed and owner stated that they would try and pull more tension on packer and retry test on Monday.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
 +
Noted that right away for flow line has been mowed to allow inspector to walkflowline area,cracks in concrete in tank area still need to be repaired.
 
|-
 
|-
| 1416254682
+
| 1158401092
| 2014-11-17
+
| 2006-09-14
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Owner called and stated that rig crew would be on site this morning to release packer and pull from well, arrived on site but rig crew did not show up as planned called company office to inquire about crew and they stated that crew got hung up in snow storm in WVA.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
 +
Note:Pump note in operation today noted that seals were out of transfer pump and hoses were leaking inside of pump house called well owner Milard Carper and requested that he replace faulty hoses and repair seal on transfer pump or replace entire pump,also noted that steam cleaning has not been preformed in tank area that was suggested on previous inspection.
 
|-
 
|-
| 1417300588
+
| 1160128383
| 2014-11-28
+
| 2006-10-04
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| On site to witness company rig release packer and start it out of hole.
+
| No violations noted, facility appears to be in satisfactory condition this inspection, walked flow line too monitor for possible leaks none found) also noted that housekeeping is suggested in tank area cracks in concrete in need of being resealed to prevent escape of brine water into fresh water strata.
 
|-
 
|-
| 1417405530
+
| 1164361592
| 2015-10-21
+
| 2006-11-20
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was not in operation today.
+
| No violations noted facility appears to be in satisfactory condition this inspection.
 +
Pump not running today,operator will need to perform housekeeping in tank area,small cracks in concrete in tank area still needs to be sealed up!weed eating on path of flow line needs preformed before weather gets too bad.
 
|-
 
|-
| 1419161005
+
| 1173468844
| 2003-06-02
+
| 2007-03-09
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted
+
| No violations noted facility appears to be in satisfactory condition this inspection,pump was not operating during my inspection  Energy Contractors tanker was unloading at facility talked to driver and suggested he replace valve on truck before returning to this facility he stated he would tell supervisor when he returned truck to Weston WVA.Also called and talked to well owner concerning cleanup needed within tank area he stated that a valve had froze up and busted allowing small amount of oil to seep out within tank area.
(3)replace oil tank in tank area,appears to be seeping on bottom seam.
 
(10)clean-up needed around flowline area
 
(12)Better restoration needed on pit area(seed+mulch needed)
 
 
|-
 
|-
| 1419620526
+
| 1175641067
| 2014-12-23
+
| 2007-04-02
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that service rig is still on site and owner is waiting on new tubing and packer to be delivered to site and once it is here they plan on running it into well and then perform required pressure testing.
+
| No vioolations noted facility appears to be in satisfactory condition this inspection.
 +
Noted that well owner is attempting too repair cracks in concrete in tank area still has quite a bit of work to do before all cracks are sealed,suggest replacing 1/4 valves on wellhead the ones in place are getting hard to work!,stone is needed on road to wellhead.
 
|-
 
|-
| 1420062416
+
| 1189721624
| 2014-12-29
+
| 2007-09-10
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| On site to witness company owned service rig start new packer and used 2.375 tubing run into well.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
Note: Old setting depth  was 5072 and there is still a cement retainer in the well bore at 5220 and I told owner if they plan on fixing well they would need to drill out the retainer and then clean out hole to total depth. Packer was equipped with on/off valve and also on/off tool we tried to set packer several times and pressure test with no positive test results at this time they will move packer assembly up hole tomorrow and try and retest.
+
Note: Pump was not operating during my inspectin,walked flow line area to monitor for leaks (none found) owner needs to clean up within tank area,noted possible seepage on two 210 bbl tanks will monitor as needed if seepage worsens will request owner remove&replace tanks.
 
|-
 
|-
| 1420066540
+
| 1194259204
| 2014-12-30
+
| 2012-11-07
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Tested casing at 5078 and test failed tested again at the following depths5032,5015 ,5007 and they also failed pressure test the rig crew shut down for the night and will resume testing tomorrow.
+
| Inspection revealed that facility is still down awaiting repairs to storage facility and pump house replacement and electrical services restored at site.
 
|-
 
|-
| 1420134575
+
| 1194388911
| 2014-12-31
+
| 2007-11-02
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| On site to witness releasing of packer and pressure testing of tubing and rig crew pulled packer up to a depth of 3272 and casing pressure tested OK and then they dropped down too 3380 and pressure tested again and it was still OK  and decision was made to further test casing integrity at deeper depths on 1/5/15.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
 +
Note: Pump was in operation during my inspection, also noted that well owner is in process of cleaning out storage tanks,noted waste container placed on unloading pad it appeared that operator has been placing sludge in container and shiping it to a approved EPA landfill.
 
|-
 
|-
| 1421091228
+
| 1195731531
| 2015-01-11
+
| 2007-11-20
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| On site along with Formation Cementing to witness cement squeeze job on defected casing they pumped 20 sacks of Class A cement and then rig crew pulled setting tool up above cement calculated top and then they pressured up on casing and well was shut in for the night and rig crew will remove tubing tomorrow and then make plans on drilling cement out from within casing and then we will pressure test casing.
+
| On site to witness clean-up efforts made by well owner,crew was steam cleaning tank area as suggested by inspector too help eliminate foul odor at unloading site,monitored H2S meter near tanks detected 6ppm  during inspection,pump was in operation during inspection.
 
|-
 
|-
| 1422998068
+
| 1195843018
| 2015-02-03
+
| 2007-11-21
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that service rig was still milling on cement retainer at 3377 and they should be ready to pressure test tomorrow.
+
| Complaint made by Susan@AbabbellasRestaurant of foul odor wants something doneabout it,told her that smell would disapate with timeran monitor around location no H2S detected,crew was on site steam cleaning tank area trying to avoid any more complaints from local citizens,suggested they have local refuge hauler come and empty dumpster(old filters and filter sacks were in it and odor was detected.
 
|-
 
|-
| 1423598499
+
| 1196722381
| 2015-02-08
+
| 2007-12-03
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that company owned service rig was still trying to retrieve plug from inside of casing and after talking to packer hand decision was made to go in hole with wash over pipe and clean up around on/off tool and then run overshot in hole and attempt to get retrievable plug from well.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
 +
Note: Pump was in operation during my inspection, walked flow line area to monitor area for potential leaks( none found),small trace of H2S odor detected on south side of storage tank area,storage tanks on south side of facility needs to be emptied and tanks properly cleaned!!!!!.
 
|-
 
|-
| 1428603162
+
| 1199308204
| 2015-09-09
+
| 2008-01-02
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection on this day indicated that owner has completed upgrades to dike area it now measurers 59x59 inside diameter and dike walls are 60 tall with a capacity of 3091 bbl. And there is 8-300 bbl. tanks connected and 2-210 bbl. Oil tanks within dike area and new pump house is going to be delivered in the next couple of days and then electrical work will begin and owner is planning on being in operation by the end of the month.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
 +
Note: Pump was not in operation during my inspection, well tender stated he had just shut pump down prior to my arrival.
 
|-
 
|-
| 1432751271
+
| 1202476629
| 2016-11-08
+
| 2007-01-02
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was in operation and well is currently operating at maximum injection pressure allowable.
+
| No violations noted facility appears to be in satisfactory condition this inspection.
 +
Pump was not running during my inspection noted operator has cleaned up oil within tank area since my last inspection but cracks in concrete still needs to be sealed.
 
|-
 
|-
| 1433021635
+
| 1202769405
| 2005-04-06
+
| 2008-02-11
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted facility appears to be in satisfactory condition this inspection.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
Tank area in need of extensive steam cleaning.
+
Note: Clean-up needed in tank area,it appears that operator ran oil tank over and it is a mess within tank area, suggest that owner steam tank area as soon as weather permits also have well operator keep a better eye on tanks and not let them run over!!!!!!!.also clean up is needed in wellhead area it appears that tubing head packing has leaked a little since my last inspection.
More stone needed in unloading area.
 
 
|-
 
|-
| 1435513803
+
| 1204580759
| 2015-06-25
+
| 2008-03-03
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| On site to witness owner spot 8-300 bbl tanks within dike area and they will place 1-210 bbl oil tank in place and then begin to plumb them up and pump house will be built in the near future and owner is going to raise dike wall by 24 to allow for calculated volumes of required storage capacity when done dike wall will be approximately 40 high.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
 +
Note: Cleanup in tank area needed,tanks need cleaned and steamed,pump was in operation during my inspection also walked flow line area to monitor for potential leaks none found).
 
|-
 
|-
| 1435892970
+
| 1207662360
| 2009-10-08
+
| 2012-02-10
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that well is in operation pump was running on the day of my inspection.
+
| On site to met with landowner and well operator to discuss issues with getting well back into operation it was agreed upon that dike walls will be replaced and pump location be mover outside of tank area and road to wellhead will be stoned before going into operation and fire suppression system be in place also.
Note: Hose on filter housing is in need of replacement it is showing signs of leakage.
 
 
|-
 
|-
| 1450120219
+
| 1211473851
| 2009-09-04
+
| 2015-05-07
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was not in operation today,on my last inpection I requested that belt guard be installed on pump  owner has not completed task as of this inspection,also noted that clean up in tank area is needed and unloading pad area needs steam cleaned also.
+
| Inspection revealed that company owned service rig on site preparing to trip out tubing and mill tomorrow.
 
|-
 
|-
| 1454353876
+
| 1217350529
| 2016-02-01
+
| 2003-04-14
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was in operation during my inspection.
+
| Stopped by service rig for update they were getting ready to pull defected tubing out of hole.
 
|-
 
|-
| 1455039776
+
| 1217886805
| 2016-02-09
+
| 2008-08-04
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Injection pump was not in operation today and in conversation with well tender they have not seen any trucks today.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
 +
Note: Pump was in operation during my inspection, walked flow line area to monitor area for potential leaks none found),also noted three company owned vac trucks unloading at facility during my inspection ,talked to well tender concerning leaking fittings on unloading plumbing he stated he would have bad fittings replaced by days end.
 
|-
 
|-
| 1455312752
+
| 1220729098
| 2016-12-21
+
| 2008-09-04
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection today indicated that injection pump was in operation and one company owned vacuum truck was unloading at he facility during my inspection.
+
| Pump not in operation today,unloading pad is in need of a good cleaning and tank area alsois in needof a steam cleaning.
 
|-
 
|-
| 1457558328
+
| 1226417143
| 2016-03-07
+
| 2008-11-10
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was not in operation during my inspection.
+
| Inspection revealed that well was not in operation during my inspection,after talking to well tender stating that well has been down for pump repair,noted that H&L Oilfield Services vac truck was unloading at site during my inspection,told well tender thhat cleanup in tank area was needed he stated that he would let well owner know that work is neededd in tank area.
 
|-
 
|-
| 1472562624
+
| 1230648854
| 2016-08-30
+
| 2011-04-28
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| On site to witness Producers Well Services perform 1000 gallon acid treatment on said well.
+
| Inspection revealed that injection pump has been removed from site of recent fire at facility,adjacient land owner called and voiced concerns if owner was planning on reopening well for commercial use.
 
|-
 
|-
| 1475831093
+
| 1236212068
| 2015-01-27
+
| 2009-03-04
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that rig crew was drilling cement out from within casing and once they get cement drilled out we will pressure test casing for integrity before they drill up the bridge plug.
+
| Inspection revealed that injection pump was not in operation today,welll tender stated that mainitence work in pump house was to be preformed today,called owner and discussed getting stone for facility and getting tank area steamed cleaned in the near future.
 
|-
 
|-
| 1476384583
+
| 1250073390
| 2016-10-13
+
| 2009-08-11
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection today indicated that injection pump was in operation and it was noted that injection pump was operating at maximum pressure allowed and in conversation with well attendant stating that they were receiving flow back only at this time and I warned them not to exceed maximum allowable pressures.
+
| Inspection revealed that well was not in operation today,instructed well tender to install new 1/4 needle valve on tubing old one is showing signs of leakage.Also inquired about getting belt guard installed on injection pump pulley,in its present state ther is a safety  issue.
 
|-
 
|-
| 1485376298
+
| 1252803534
| 2017-01-25
+
| 2014-10-27
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Pressures were recorded prior to acid treatment, Producers Services on site to perform 1000 gallon acid treatment on said well they pumped 500 gallon of 28% then displaced into formation and they let it soak for 30 minutes and then they pumped another 500 gallon of 15% acid and then displaced it into formation and owner is going to let acid soak overnight before pacing well back into operation.
+
| Stopped by well site to check on work crew that is making upgrades to facility.
 
 
Note: Two UIC staff members from central office were on site to witness acid treatment job today.
 
 
|-
 
|-
| 1500924787
+
| 1254363886
| 2017-07-24
+
| 2010-12-29
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection today revealed that injection pump was in operation and it was noted that one company owned tanker was unloading at the facility during my inspection.
+
| Inspected site along with supervisor and inspection revealed that pump was in operation today.
 +
Note: Platform at wellhead is needed so inspector doesnt have to climb on tubing head to place gauge on and more cleanup around wellhead is needed there is still old pit liner and lumber that needs to be removed from site and as weather permits vegetation needs to be established in area of old working pit.
 
|-
 
|-
| 1509130040
+
| 1257841499
| 2017-10-27
+
| 2004-02-10
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection today revealed that injection pump was in operation during my inspection and it was noted that well is currently operating at maximum allowable pressure.
+
| No violations noted facility appears to be in good repair.
 +
(1)tank I.D.needs refreshed
 +
(3)extensive cleaning needed in tank area
 +
(11)housekeeping needed in unloading pad area
 +
Note:old 100bbl oil tank needs removed from site!
 
|-
 
|-
| 1512595831
+
| 1259i193
| 2017-12-06
+
| 2002-10-30 0:00
| Salt Water Injection Well
+
| SW
 
| No Violations
 
| No Violations
| Inspection today indicated that injection pump was in operation and it was noted that one CS Trucking vacuum truck was unloading at the facility during my inspection.
+
|  
 
|-
 
|-
| 1523385418
+
| 1265755723
| 2018-04-09
+
| 2010-02-09
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection today indicated that injection pump was in operation and it was noted that one Monroe Drilling vacuum truck was offloading at the facility during my inspection and it was noted that proper identification was missing from truck told driver and also called truck owner that truck must be properly identified before they haul any more brine.
+
| Well down for repair, injection pressure and annulus pressure equalized .Talked to well owner Millard Carper and suggested that he bleed off pressure on backside of tubing then reapply pressure and I would monitor it for compliance.
 
|-
 
|-
| 1525433948
+
| 1268771824
| 2011-09-14
+
| 2010-03-16
| Salt Water Injection Well
+
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| FOLLOW UP TO NOV #  1316122404 Inspection revealed that well is not in operation and has been idle for several months.  Tank area has water build up that needs to be hauled to another disposal facility. Plug or put well back into operation after relocating unloading pad and tank/pump house areas.  Failure to comply may result in bond forfeiture.
+
| Stopped by well site to check on rig ,they were mixing Calcium Chloride to weight up water to kill well so they could pull tubing and then go in well to drill up cement retainer and then run new packer assembly in well and if all goes good place well back into operation.
 
|-
 
|-
| 1526054504
+
| 1269124297
| 2018-05-11
+
| 2010-03-19
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was in operation during my inspection and one company owned vacuum truck was on site during my inspection.
+
| Stopped by service rig for update,rig crew was rigging up power swivel and mud pump in preparation to drill out cement retainer.3/20/2010 Rig operator called and stated they had drilled up retainer and possibly will be ready to run packer and tubing in well 3/22/2010.
 
|-
 
|-
| 1529248713
+
| 1269296520
| 2018-06-13
+
| 2010-03-22
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection today indicated that injection pump was in operation and it was noted that two company owned vacuum trucks were offloading at the site during my inspection.
+
| On site to witness rig operator start new Patriot Packer in hole, will continue to run the rest of tubing 3/23/10 and pressure test annulus of tubing if Packer passes required testing.
 
|-
 
|-
| 1532041234
+
| 1269389403
| 2018-07-17
+
| 2010-03-23
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was not in operation during my inspection and according to well operator injection pump has not run since last week.
+
| On site to witness rig crew run tubing and set packer@5165 informed owner that he would be required to request variance on packer setting depth because they are not within 100 of top perf,called Central Office and talked to UIC supervisor regarding setting depth of packer.
 
+
Note: Packer is equipped with down hole shut off valve and setting depth is 5165 Patriot model T 607.
 
 
Note: Two company owned vacuum trucks were offloading at the facility during my inspection.
 
 
|-
 
|-
| 1532367729
+
| 1271368944
| 2010-08-05
+
| 2010-04-13
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that service rig is still rigged up on well and crew is trying to determine if production casing has a hole in it and it was stated that they thought new packer element was not holding properly and that a new packer had possibly been ordered.
+
| Inspection revealed that injection pump was not in operation during my inspection.
 +
Note: Called company in reguards too restoration work needed at site,area needs to be seeded and mulched to help prevent erosion issues at site and old plastic pit liner needs to be properly disposed of.
 
|-
 
|-
| 1542831200
+
| 1275050552
| 2018-11-21
+
| 2017-12-28
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was in operation during my inspection.
+
| Inspection revealed that injection pump was in operation during my inspection and operating at maximum allowable pressure and in conversation with operator stating that they were receiving flowback water at this time.
 
 
Note: Informed owner that unloading pad area is in need of a good cleaning.
 
 
|-
 
|-
| 1549914798
+
| 1275517476
| 2019-02-11
+
| 2010-06-02
 
| Salt Water Injection Well
 
| Salt Water Injection Well
| Violations Noted
+
| No Violations
| The Division has not received the 4th quarter brine disposal fees for 2018. Please forward disposal fees and sheets to the Division by 3/12/2019.
+
| Inspection revealed that well has equalized, called company and requested that they repair well, they stated that they would have service rig on well within the next couple days and they would pull tubing and packer and inspect element on packer and check for possible hole in tubing.
 
|-
 
|-
| 1564672871
+
| 1276901772
| 2015-01-08
+
| 2010-06-18
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No activity at site today due too extreme cold weather conditions.
+
| Stopped by service rig for update they were attempting to kill well in preparation to pull tubing and packer, rig operator called and stated they had removed tubing and packer from well and would attach swedge and valve to casing and shut it in for the weekend .
 
|-
 
|-
| 1581297244
+
| 1277672162
| 2008-04-02
+
| 2010-06-26
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| On site at request of well owner too witness running of tubing and packer in hole to test for integrity of casing and tubing, arrived on site and witnessed rig operator run casing scrapper in hole to remove scale and any other obstruction that might hinder setting of packer element. Operator was unable to start running packer and tubing due to fact well was still flowing back told them to get well killed and once they reached that point call Inspector so he can come to site and witness running of tubing and packer in well.
Pump was not in operation during my inspection also noted that new 2 check valve has been installed at wellhead since my last inspection, also noted that tank within dike has been run over since my last inspection steam cleaning tank area is highly advised and reseal cracks in concrete to ensure proper integrity of tank area.
 
 
|-
 
|-
| 1618385507
+
| 1277672809
| 2018-08-16
+
| 2010-06-27
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection today indicated that injection pump was down for repair, operator stated that parts were in route and they hoped too be up and in operation later today.
+
| Rig operator called and stated they were ready to run tubing and packer into well,upon arriving on site it was determined that well was not static decision was made to mix more kill fluid and try again tomorrow.
 
|-
 
|-
| 1635545047
+
| 1277766028
| 2005-12-08
+
| 2010-06-28
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection,noted that replumbing of piping at facility has been completed.
+
| Onsite to witness operator run tubing and packer in well,setting depth was 5198.30 pressured up on annulus to 1270 psi and monitored pressure for 15 min pressure declined to 980 psi at end of test (TEST FAILED) will attempt to move packer up hole 8 tomorrow and retest.
Housekeeping in tank area needed as weather permits.
 
 
|-
 
|-
| 1650270922
+
| 1278154931
| 2016-04-12
+
| 2010-07-02
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection today revealed that injection pump was in operation and in conversation with well attendant stating that they were receiving fluids from Flex Water facility and various sites from Eclipse Resources at the present time.
+
| Stopped by service rig for update on trying to repair casing they think that 4.5 possibly has hole in it above cement top is estimated to be@approximatly 900 according to E-logs at site, will continue to monitor well site for compliance.
 
|-
 
|-
| 1676197129
+
| 1279309367
| 2018-08-20
+
| 2010-07-13
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Cleaning off unloading pad today with steam cleaner/power washer.
+
| On site to witness rig operator run 1.5 tubing down backside of production casing and tag cement top and then pump cement slurry in casing to seal off any potential leakage in 4.5 casing, will retest annulus of tubing string and packer integrity in near future.
 
|-
 
|-
| 1683461129
+
| 1283288298
| 2005-07-13
+
| 2010-08-31
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| Stopped but service rig for update on running packer and tubing back in well too test for casing integrity and to flush annulus of tubing and add fresh water and inhibitor to backside of tubing if testing indicates that we have good integrity.
During my inspection noted Energy Contractors truck unloading at site noted faulty 3valve on vac truck instructed driver to replace valve before returning to well.
+
Note: Owner  will possibly want to set packer at higher depth in hole, suspects faulty casing at old setting depth.
Need path to wellhead weedeated in area of flowline,cant properly inspect line when it buried in tall weeds.
 
 
|-
 
|-
| 1791113881
+
| 1284161485
| 2005-08-08
+
| 2010-09-10
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| Inspection revealed that well is not in operation at this time, on site to witness rig crew mix kill water and then packer rep attempted to release packer and set at higher depth, packer was released and we moved packer up hole one joint at a time and attempted pressure test, once we reached 5006 and packer would not set decision was made to pull packer from well and have packer rep rebuild it and we will run it back in hole as soon as it is delivered back to well site.
Conversation with well owner concerning cleaning of storage tanks told him that all waste from tanks needed to be hauled to EPA approved landfill closest on around is located in Brownville Oh.
 
 
|-
 
|-
| 1819170680
+
| 1285196310
| 2007-05-03
+
| 2010-09-22
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection..
+
| Stopped by well site to check on service rig crew, they were mixing calcium chloride in attempt too kill well and possibly start new packer in hole.
Note: Pump was running during my inspection,weed eating needed along flow line area and around wellhead!!!!!!,also housekeeping needed in tank area&tank area also.
 
 
|-
 
|-
| 1824766083
+
| 1293304785
| 2007-11-23
+
| 2011-05-09
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Stopped by well site and check on cleanup and monitor air quality o2 level 20.9 north side of tanks no H2S detected 20.6 inside of pump house slight H2S odor detected would not register on gas meter,told well tender to call owner and have injection pump worked on #2&3 cylinders are in need of repair or replacement noted leakage on both.Contacted well owner and suggested he have pump worked on ASAP he agreed,picked up ticket for water they received 11/13/07 from BOBCAT OIL&GAS,Wayne WVA.suspect that was site of foul smelling water received at well site.
+
| Stopped by site to check on fluid level in dike area there was approximatly 6 of fluid in dike with very low brine content it will need to be removed from dike and hauled to another disposal well.
 
|-
 
|-
| 1826454894
+
| 1296272525
| 2015-01-07
+
| 2010-03-30
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| My inspection today finds the casing is being tested for holes.  Carper Well Service is using a packer to test the 4.5 casing.  The holes appear to be between 3380 and 3420.
+
| Stopped by well to check on injection pump for leakage after start up at facility,none detected.
 +
Note: Pit at wellhead needs to be emptied ASAP and area restored and seeded and mulched to help prevent erosion at wellsite.
 
|-
 
|-
| 1841183360
+
| 1298254422
| 2017-06-02
+
| 2013-09-13
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealedthat injection pump was in operation and it was noted that flowline area and wellhead area has been recently mowed and looks good.
+
| Inspection revealed that well is still down awaiting on work over plan to be approved by Central Office.
 
|-
 
|-
| 1841534296
+
| 1301171506
| 2016-03-24
+
| 2011-03-26
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was not in operation today and it was stated by operator that they have not run injection pump since the first part of the week.
+
| Received call from Com Center of tank fire south of Belle Valley on state route 821,investigated site and found that fire started in pump house area and then spread to tank area and all tanks and pump house were a total loss, two 210 bbl tanks erupted and landed on adjacent building and one landed in parking area, there was 6 fire departments responded and one officer from parks and one officer from wildlife were also on scene and three Noble county law enforcement officers were also present.
 +
Once fire was put out and site evaluated it was determined that no brine/oil had escaped from dike area and I told well owner to remove all fluids from dike area and empty all remaining tanks at site and haul to another disposal well, will check on situation tomorrow.
 
|-
 
|-
| 1852116223
+
| 1301240842
| 2011-05-19
+
| 2011-03-27
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| On site with Tom Tomastik to inspect well site.
+
| Inspected site to check on compliance of inspectors directions of removing brine from dike area and too also check on any potential tank leakage none noted and all but two storage tanks have been emptied and they will be hauled out tomorrow and taken to another disposal well will check back in on site at later date to check up on clean up detail.
 
 
Note:  Tom confirmed with my findings that entire dike facility needs to be replaced before placing well back into operation.
 
 
|-
 
|-
| 1865560157
+
| 1301519834
| 2019-03-06
+
| 2011-03-30
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection today indicated that injection pump was in operation during my inspection.
+
| Visited site along with supervisor and we discussed events of recent fire at site and it was determined that if owner decides to rebuild facility concrete dike will need to be replaced not repaired.
 
|-
 
|-
| 1872303264
+
| 1304716629
| 2014-07-22
+
| 2011-05-05
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that well is still down waiting on owner to start rebuilding process.
+
| Inspection revealed that well is not in operation due to fact of recent fire destroying injection pump and tank facility and dike area.
 
|-
 
|-
| 1886853626
+
| 1305694384
| 2010-01-20
+
| 2006-04-04
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that pump was in operation today, noted H&L Water was unloading at facility during my inspection.
+
| No violations noted, facility appears to be in satisfactory condition this inspection.
Note: Unable to check tubing pressure due to fact there was ice in valve, stopped at pump house and suggested too operator that they thaw out valve and place 1/4 plug in it to insure that valve is working properly.
+
Note:Tank area in need of severe cleaning as soon as weather permits,also stone needed on lease road to wellhead,weedeating needed in area of flow line to wellhead.
 
|-
 
|-
| 1890846684
+
| 1310603768
| 2004-10-18
+
| 2011-07-13
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility in satisfactory condition this inspection.
+
| Inspection revealed that well is still down for repair, several storage tanks have been removed from dike area there is three remaining tanks within dike 1-210 bbl and 2-100 bbl tanks it appears that owner is planning on cleaning up area within dike and possibly rebuilding injection facility.
Pump not running today.
 
Housekeeping needed in tank area.
 
 
|-
 
|-
| 1912702274
+
| 1314994147
| 2004-09-14
+
| 2011-08-31
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| Inspection revealed that well is out of service due to fact that tank site and pump house burnt up in recent fire at facility, water within tank area needs to be removed and weeds going to wellhead need to be cut and if well is going to be repaired unloading pad and tank site will need to be moved to a new location.
(6) Need to replace 1/4 valve at wellhead (tubing pressure side).
 
 
|-
 
|-
| 1919132471
+
| 1316122404
| 2015-11-27
+
| 2011-09-14
 
| Salt Water Injection Well
 
| Salt Water Injection Well
| No Violations
+
| Violations Noted
| Inspection revealed that injection pump was in operation during my inspection and it was noted that one Ramco vacuum truck was unloading at the facility during my inspection.
+
| Inspection revealed that well is not in operation and has been idle for several months, tank area has water build up and needs to be hauled to another disposal facility.
 +
Plug or put well back into operation after relocating unloading pad and tank and pump house areas.
 +
Failure to comply may result in bond forfeiture.
 
|-
 
|-
| 1922802762
+
| 1323379584
| 2015-06-08
+
| 2011-12-08
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| MIT test passed well is capable of injecting fluid and this resolves previous compliance notice issued.
+
| Inspection revealed that there has been no change in status of well it still remains idle and owner has made no attempts to place well back into operation.
 
|-
 
|-
| 1928889728
+
| 1332629825
| 2010-06-16
+
| 2012-03-23
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Stopped by service rig too check and see if they had well killed and were ready to release packer and pull tubing, they were still mixing calcium chloride to get fluid weight to 12.5+ so well would become static and then they would release packer and pull tubing.
+
| Inspection revealed that well is not in operation at this time, owner is trying to make a deal with another operator to take over well and place back into operation.
 
|-
 
|-
| 1956712549
+
| 1333834625
| 2003-11-18
+
| 2012-04-06
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted,facility appears to be in good repair.
+
| Well is down for repair and replacement of tanks and injection pump and upgrades being made too facility.
(3)Clean-up needed in tank area! 100bbl oil tank needs to be replaced.
 
(11)Housekeeping needed in unloading area.
 
(12)Restoration still needed aronnd wellhead.
 
 
|-
 
|-
| 1969386471
+
| 1339110616
| 2006-02-13
+
| 2012-06-04
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| Inspection revealed that well is still down for repair, it was noted that all old storage tanks have been removed from site and it was also noted that vault in unloading pad has been emptied.
Note: Pump was running on the day of my inspection,walked flowline.
 
Could use some stone on lease road to wellhead!
 
Tank area needs steamed cleaned as soon as weather permits.
 
 
|-
 
|-
| 1979004610
+
| 1351488117
| 2018-05-04
+
| 2004-05-10
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was in operation during my inspection.
+
| No violations noted,facility appears to be in satisfactory condition this inspection.
 +
(3)housekeeping needed in tank area(steamed cleaned)
 +
(11)housekeeping needed in unloading area.
 
|-
 
|-
| 2019628224
+
| 1363030194
| 2005-02-04
+
| 2013-03-11
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| No violations noted, facility appears to be in satisfactory condition this inspection.
+
| Inspection revealed that injection well is still down awaiting on owner to rebuild tank facility and pump house, they had fire at facility a couple years ago.
(3) Housekeeping needed in tank area.
+
 
(11) Area around unloading pad in need of stone to help from tracking mud onto state highway when truck are leaving site.
 
 
|-
 
|-
| 2037920083
+
| 1376609958
| 2014-12-10
+
| 2018-05-14
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Company rep on site with swab rig to run casing scrapper in well and clean up the interior wall of the casing and once completed they will run new packer and tubing in well and perform MIT test and once testing is complete they will start construction of pump house.
+
| Inspection revealed that injection pump was not in operation today due too fact they are preparing to have all of there storage tanks cleaned out.
 
|-
 
|-
| 2092464991
+
| 1384500063
| 2013-10-15
+
| 2009-02-12
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that well is still idle and owner has submitted rebuild plan to the division and they are waiting on approval of plan.
+
| Inspection revealed that injection pump was in operation during my inspection, noted that storage tanks had run over all spillage was contained within dike ,talked to well tender and suggested that they have tanks cleaned as soon as weather permits.
 +
Note: STONE IS NEEDED AROUND FACILITY TO HELP KEEP MUD FROM ENTERING HIGHWAY!!!!!!
 
|-
 
|-
| 2100004227
+
| 1389820083
| 2016-01-06
+
| 2014-01-15
| Annular Disposal
+
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Injection pump was in operation on the day of my inspection.
+
| Inspection revealed that well is still down waiting on plan to be submitted to rebuild facility to current industry standards.
 
|-
 
|-
| 2102879171
+
| 1398286402
| 2015-12-29
+
| 2014-04-23
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection revealed that injection pump was in operation on this day of my inspection.
+
| Inspection revealed that well is still down awaiting on rebuild plan to be submitted to Central Office.
 +
 
 +
Note: Called company and requested that they have positive pressure applied to annulus of tubing.
 
|-
 
|-
| 2130911311
+
| 1400017013
| 2015-05-18
+
| 2014-05-13
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Stopped by service rig for update they are currently stuck in hole at 5380 we worked string and tubing became free and they were able to pump fluid around bit and continue to clean out wellbore.
+
| Inspection revealed that well is still down waiting on owner to rebuild facility.
 +
Note: On site along with Ryan Carper to pressure test annulus of tubing he applied 1000# of pressure and we monitored it for 15+ minutes with no decline in pressure.
 
|-
 
|-
| 2133064485
+
| 1407867614
| 2017-03-14
+
| 2014-08-12
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
| Inspection today revealed that injection pump was in operation during my inspection.
+
| Inspection revealed that well is still down waiting on owner to repair well or sell it to a responsible owner.
 
|-
 
|-
| 2143814339
+
| 1409215036
| 2018-03-11
+
| 2016-07-21
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that injection pump was not in operation during my inspection.
 +
|-
 +
| 1414002865
 +
| 2014-10-22
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that Crescent Supply crew is on site placing felt padding in dike area and once it is in place they will place 60 mil liner in place and spot storage tanks after that point.
 +
|-
 +
| 1415357458
 +
| 2014-11-05
 +
| Salt Water Injection Well
 +
| No Violations
 +
| On site to witness rig crew pull tension on tubing string and then tighten up tubing head to try and fix small leak noted on it on my last inspection after they tightened it up they applied pressure and we noticed another small leak we will retighten it later this week and retest it.
 +
|-
 +
| 1415472044
 +
| 2014-11-07
 +
| Salt Water Injection Well
 +
| No Violations
 +
| On site to witness owner attempt to pressure test annulus of tubing after they made repairs to tubing head they pressured up to1275 and we monitored pressure for 15 minutes and at the end of test period pressure had dropped too 900 psi and test failed and owner stated that they would try and pull more tension on packer and retry test on Monday.
 +
|-
 +
| 1416254682
 +
| 2014-11-17
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Owner called and stated that rig crew would be on site this morning to release packer and pull from well, arrived on site but rig crew did not show up as planned called company office to inquire about crew and they stated that crew got hung up in snow storm in WVA.
 +
|-
 +
| 1417300588
 +
| 2014-11-28
 +
| Salt Water Injection Well
 +
| No Violations
 +
| On site to witness company rig release packer and start it out of hole.
 +
|-
 +
| 1417405530
 +
| 2015-10-21
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that injection pump was not in operation today.
 +
|-
 +
| 1419161005
 +
| 2003-06-02
 +
| Salt Water Injection Well
 +
| No Violations
 +
| No violations noted
 +
(3)replace oil tank in tank area,appears to be seeping on bottom seam.
 +
(10)clean-up needed around flowline area
 +
(12)Better restoration needed on pit area(seed+mulch needed)
 +
|-
 +
| 1419620526
 +
| 2014-12-23
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that service rig is still on site and owner is waiting on new tubing and packer to be delivered to site and once it is here they plan on running it into well and then perform required pressure testing.
 +
|-
 +
| 1420062416
 +
| 2014-12-29
 +
| Salt Water Injection Well
 +
| No Violations
 +
| On site to witness company owned service rig start new packer and used 2.375 tubing run into well.
 +
Note: Old setting depth  was 5072 and there is still a cement retainer in the well bore at 5220 and I told owner if they plan on fixing well they would need to drill out the retainer and then clean out hole to total depth.  Packer was equipped with on/off valve and also on/off tool we tried to set packer several times and pressure test with no positive test results at this time they will move packer assembly up hole tomorrow and try and retest.
 +
|-
 +
| 1420066540
 +
| 2014-12-30
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Tested casing at 5078 and test failed tested again at the following depths5032,5015 ,5007 and they also failed pressure test the rig crew shut down for the night and will resume testing tomorrow.
 +
|-
 +
| 1420134575
 +
| 2014-12-31
 +
| Salt Water Injection Well
 +
| No Violations
 +
| On site to witness releasing of packer and pressure testing of tubing and rig crew pulled packer up to a depth of 3272 and casing pressure tested OK and then they dropped down too 3380 and pressure tested again and it was still OK  and decision was made to further test casing integrity at deeper depths on 1/5/15.
 +
|-
 +
| 1421091228
 +
| 2015-01-11
 +
| Salt Water Injection Well
 +
| No Violations
 +
| On site along with Formation Cementing to witness cement squeeze job on defected casing they pumped 20 sacks of Class A cement and then rig crew pulled setting tool up above cement calculated top and then they pressured up on casing and well was shut in for the night and rig crew will remove tubing tomorrow and then make plans on drilling cement out from within casing and then we will pressure test casing.
 +
|-
 +
| 1422998068
 +
| 2015-02-03
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that service rig was still milling on cement retainer at 3377 and they should be ready to pressure test tomorrow.
 +
|-
 +
| 1423598499
 +
| 2015-02-08
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that company owned service rig was still trying to retrieve plug from inside of casing and after talking to packer hand decision was made to go in hole with wash over pipe and clean up around on/off tool and then run overshot in hole and attempt to get retrievable plug from well.
 +
|-
 +
| 1428603162
 +
| 2015-09-09
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection on this day indicated that owner has completed upgrades to dike area it now measurers 59x59 inside diameter and dike walls are 60 tall with a capacity of 3091 bbl. And there is 8-300 bbl. tanks connected and 2-210 bbl. Oil tanks within dike area and new pump house is going to be delivered in the next couple of days and then electrical work will begin and owner is planning on being in operation by the end of the month.
 +
|-
 +
| 1432751271
 +
| 2016-11-08
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that injection pump was in operation and well is currently operating at maximum injection pressure allowable.
 +
|-
 +
| 1433021635
 +
| 2005-04-06
 +
| Salt Water Injection Well
 +
| No Violations
 +
| No violations noted facility appears to be in satisfactory condition this inspection.
 +
Tank area in need of extensive steam cleaning.
 +
More stone needed in unloading area.
 +
|-
 +
| 1435513803
 +
| 2015-06-25
 +
| Salt Water Injection Well
 +
| No Violations
 +
| On site to witness owner spot 8-300 bbl tanks within dike area and they will place 1-210 bbl oil tank in place and then begin to plumb them up and pump house will be built in the near future and owner is going to raise dike wall by 24 to allow for calculated volumes of required storage capacity when done dike wall will be approximately 40 high.
 +
|-
 +
| 1435892970
 +
| 2009-10-08
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that well is in operation pump was running on the day of my inspection.
 +
Note: Hose on filter housing is in need of replacement it is showing signs of leakage.
 +
|-
 +
| 1450120219
 +
| 2009-09-04
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that injection pump was not in operation today,on my last inpection I requested that belt guard be installed on pump  owner has not completed task as of this inspection,also noted that clean up in tank area is needed and unloading pad area needs steam cleaned also.
 +
|-
 +
| 1454353876
 +
| 2016-02-01
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that injection pump was in operation during my inspection.
 +
|-
 +
| 1455039776
 +
| 2016-02-09
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Injection pump was not in operation today and in conversation with well tender they have not seen any trucks today.
 +
|-
 +
| 1455312752
 +
| 2016-12-21
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection today indicated that injection pump was in operation and one company owned vacuum truck was unloading at he facility during my inspection.
 +
|-
 +
| 1457558328
 +
| 2016-03-07
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that injection pump was not in operation during my inspection.
 +
|-
 +
| 1472562624
 +
| 2016-08-30
 +
| Salt Water Injection Well
 +
| No Violations
 +
| On site to witness Producers Well Services perform 1000 gallon acid treatment on said well.
 +
|-
 +
| 1475831093
 +
| 2015-01-27
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that rig crew was drilling cement out from within casing and once they get cement drilled out we will pressure test casing for integrity before they drill up the bridge plug.
 +
|-
 +
| 1476384583
 +
| 2016-10-13
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection today indicated that injection pump was in operation and it was noted that injection pump was operating at maximum pressure allowed and in conversation with well attendant stating that they were receiving flow back only at this time and I warned them not to exceed maximum allowable pressures.
 +
|-
 +
| 1485376298
 +
| 2017-01-25
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Pressures were recorded prior to acid treatment, Producers Services on site to perform 1000 gallon acid treatment on said well they pumped 500 gallon of 28% then displaced into formation and they let it soak for 30 minutes and then they pumped another 500 gallon of 15% acid and then displaced it into formation and owner is going to let acid soak overnight before pacing well back into operation.
 +
 
 +
Note: Two UIC staff members from central office were on site to witness acid treatment job today.
 +
|-
 +
| 1500924787
 +
| 2017-07-24
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection today revealed that injection pump was in operation and it was noted that one company owned tanker was unloading at the facility during my inspection.
 +
|-
 +
| 1509130040
 +
| 2017-10-27
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection today revealed that injection pump was in operation during my inspection and it was noted that well is currently operating at maximum allowable pressure.
 +
|-
 +
| 1512595831
 +
| 2017-12-06
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection today indicated that injection pump was in operation and it was noted that one CS Trucking vacuum truck was unloading at the facility during my inspection.
 +
|-
 +
| 1523385418
 +
| 2018-04-09
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection today indicated that injection pump was in operation and it was noted that one Monroe Drilling vacuum truck was offloading at the facility during my inspection and it was noted that proper identification was missing from truck told driver and also called truck owner that truck must be properly identified before they haul any more brine.
 +
|-
 +
| 1525433948
 +
| 2011-09-14
 +
| Salt Water Injection Well
 +
| No Violations
 +
| FOLLOW UP TO NOV #  1316122404 Inspection revealed that well is not in operation and has been idle for several months.  Tank area has water build up that needs to be hauled to another disposal facility.  Plug or put well back into operation after relocating unloading pad and tank/pump house areas.  Failure to comply may result in bond forfeiture.
 +
|-
 +
| 1526054504
 +
| 2018-05-11
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that injection pump was in operation during my inspection and one company owned vacuum truck was on site during my inspection.
 +
|-
 +
| 1529248713
 +
| 2018-06-13
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection today indicated that injection pump was in operation and it was noted that two company owned vacuum trucks were offloading at the site during my inspection.
 +
|-
 +
| 1532041234
 +
| 2018-07-17
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that injection pump was not in operation during my inspection and according to well operator injection pump has not run since last week.
 +
 
 +
 
 +
Note: Two company owned vacuum trucks were offloading at the facility during my inspection.
 +
|-
 +
| 1532367729
 +
| 2010-08-05
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that service rig is still rigged up on well and crew is trying to determine if production casing has a hole in it and it was stated that they thought new packer element was not holding properly and that a new packer had possibly been ordered.
 +
|-
 +
| 1542831200
 +
| 2018-11-21
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that injection pump was in operation during my inspection.
 +
 
 +
Note: Informed owner that unloading pad area is in need of a good cleaning.
 +
|-
 +
| 1549914798
 +
| 2019-02-11
 +
| Salt Water Injection Well
 +
| Violations Noted
 +
| The Division has not received the 4th quarter brine disposal fees for 2018. Please forward disposal fees and sheets to the Division by 3/12/2019.
 +
|-
 +
| 1563722676
 +
| 2019-7-19 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 1564672871
 +
| 2015-01-08
 +
| Salt Water Injection Well
 +
| No Violations
 +
| No activity at site today due too extreme cold weather conditions.
 +
|-
 +
| 1581297244
 +
| 2008-04-02
 +
| Salt Water Injection Well
 +
| No Violations
 +
| No violations noted, facility appears to be in satisfactory condition this inspection.
 +
Pump was not in operation during my inspection also noted that new 2 check valve has been installed at wellhead since my last inspection, also noted that tank within dike has been run over since my last inspection steam cleaning tank area is highly advised and reseal cracks in concrete to ensure proper integrity of tank area.
 +
|-
 +
| 1587417154
 +
| 2020-4-20 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 16158636
 +
| 2020-10-13 0:00
 +
| SW
 +
| No Violations
 +
| 4.00
 +
|-
 +
| 1618385507
 +
| 2018-08-16
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection today indicated that injection pump was down for repair, operator stated that parts were in route and they hoped too be up and in operation later today.
 +
|-
 +
| 1635545047
 +
| 2005-12-08
 +
| Salt Water Injection Well
 +
| No Violations
 +
| No violations noted, facility appears to be in satisfactory condition this inspection,noted that replumbing of piping at facility has been completed.
 +
Housekeeping in tank area needed as weather permits.
 +
|-
 +
| 1650270922
 +
| 2016-04-12
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection today revealed that injection pump was in operation and in conversation with well attendant stating that they were receiving fluids from Flex Water facility and various sites from Eclipse Resources at the present time.
 +
|-
 +
| 1676197129
 +
| 2018-08-20
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Cleaning off unloading pad today with steam cleaner/power washer.
 +
|-
 +
| 1683461129
 +
| 2005-07-13
 +
| Salt Water Injection Well
 +
| No Violations
 +
| No violations noted, facility appears to be in satisfactory condition this inspection.
 +
During my inspection noted Energy Contractors truck unloading at site noted faulty 3valve on vac truck instructed driver to replace valve before returning to well.
 +
Need path to wellhead weedeated in area of flowline,cant properly inspect line when it buried in tall weeds.
 +
|-
 +
| 174001850
 +
| 2017-4-28 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 1771712023
 +
| 2020-8-14 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 1791113881
 +
| 2005-08-08
 +
| Salt Water Injection Well
 +
| No Violations
 +
| No violations noted, facility appears to be in satisfactory condition this inspection.
 +
Conversation with well owner concerning cleaning of storage tanks told him that all waste from tanks needed to be hauled to EPA approved landfill closest on around is located in Brownville Oh.
 +
|-
 +
| 1819170680
 +
| 2007-05-03
 +
| Salt Water Injection Well
 +
| No Violations
 +
| No violations noted, facility appears to be in satisfactory condition this inspection..
 +
Note: Pump was running during my inspection,weed eating needed along flow line area and around wellhead!!!!!!,also housekeeping needed in tank area&tank area also.
 +
|-
 +
| 1824766083
 +
| 2007-11-23
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Stopped by well site and check on cleanup and monitor air quality o2 level 20.9 north side of tanks no H2S detected 20.6 inside of pump house slight H2S odor detected would not register on gas meter,told well tender to call owner and have injection pump worked on #2&3 cylinders are in need of repair or replacement noted leakage on both.Contacted well owner and suggested he have pump worked on ASAP he agreed,picked up ticket for water they received 11/13/07 from BOBCAT OIL&GAS,Wayne WVA.suspect that was site of foul smelling water received at well site.
 +
|-
 +
| 1826454894
 +
| 2015-01-07
 +
| Salt Water Injection Well
 +
| No Violations
 +
| My inspection today finds the casing is being tested for holes.  Carper Well Service is using a packer to test the 4.5 casing.  The holes appear to be between 3380 and 3420.
 +
|-
 +
| 1841183360
 +
| 2017-06-02
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealedthat injection pump was in operation and it was noted that flowline area and wellhead area has been recently mowed and looks good.
 +
|-
 +
| 1841534296
 +
| 2016-03-24
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that injection pump was not in operation today and it was stated by operator that they have not run injection pump since the first part of the week.
 +
|-
 +
| 1852116223
 +
| 2011-05-19
 +
| Salt Water Injection Well
 +
| No Violations
 +
| On site with Tom Tomastik to inspect well site.
 +
 
 +
Note:  Tom confirmed with my findings that entire dike facility needs to be replaced before placing well back into operation.
 +
|-
 +
| 185563784
 +
| 2006-5-2 0:00:0
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 1865560157
 +
| 2019-03-06
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection today indicated that injection pump was in operation during my inspection.
 +
|-
 +
| 1872303264
 +
| 2014-07-22
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that well is still down waiting on owner to start rebuilding process.
 +
|-
 +
| 1882426079
 +
| 2020-2-20 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 1886853626
 +
| 2010-01-20
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that pump was in operation today, noted H&L Water was unloading at facility during my inspection.
 +
Note: Unable to check tubing pressure due to fact there was ice in valve, stopped at pump house and suggested too operator that they thaw out valve and place 1/4 plug in it to insure that valve is working properly.
 +
|-
 +
| 1890846684
 +
| 2004-10-18
 +
| Salt Water Injection Well
 +
| No Violations
 +
| No violations noted, facility in satisfactory condition this inspection.
 +
Pump not running today.
 +
Housekeeping needed in tank area.
 +
|-
 +
| 1912702274
 +
| 2004-09-14
 +
| Salt Water Injection Well
 +
| No Violations
 +
| No violations noted, facility appears to be in satisfactory condition this inspection.
 +
(6) Need to replace 1/4 valve at wellhead (tubing pressure side).
 +
|-
 +
| 1919132471
 +
| 2015-11-27
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that injection pump was in operation during my inspection and it was noted that one Ramco vacuum truck was unloading at the facility during my inspection.
 +
|-
 +
| 1922802762
 +
| 2015-06-08
 +
| Salt Water Injection Well
 +
| No Violations
 +
| MIT test passed well is capable of injecting fluid and this resolves previous compliance notice issued.
 +
|-
 +
| 1928889728
 +
| 2010-06-16
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Stopped by service rig too check and see if they had well killed and were ready to release packer and pull tubing, they were still mixing calcium chloride to get fluid weight to 12.5+ so well would become static and then they would release packer and pull tubing.
 +
|-
 +
| 1956712549
 +
| 2003-11-18
 +
| Salt Water Injection Well
 +
| No Violations
 +
| No violations noted,facility appears to be in good repair.
 +
(3)Clean-up needed in tank area! 100bbl oil tank needs to be replaced.
 +
(11)Housekeeping needed in unloading area.
 +
(12)Restoration still needed aronnd wellhead.
 +
|-
 +
| 1969386471
 +
| 2006-02-13
 +
| Salt Water Injection Well
 +
| No Violations
 +
| No violations noted, facility appears to be in satisfactory condition this inspection.
 +
Note: Pump was running on the day of my inspection,walked flowline.
 +
Could use some stone on lease road to wellhead!
 +
Tank area needs steamed cleaned as soon as weather permits.
 +
|-
 +
| 1979004610
 +
| 2018-05-04
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that injection pump was in operation during my inspection.
 +
|-
 +
| 200022468
 +
| 2020-5-4 0:00:0
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 2006298469
 +
| 2019-9-5 0:00:0
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 2019628224
 +
| 2005-02-04
 +
| Salt Water Injection Well
 +
| No Violations
 +
| No violations noted, facility appears to be in satisfactory condition this inspection.
 +
(3) Housekeeping needed in tank area.
 +
(11) Area around unloading pad in need of stone to help from tracking mud onto state highway when truck are leaving site.
 +
|-
 +
| 2037920083
 +
| 2014-12-10
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Company rep on site with swab rig to run casing scrapper in well and clean up the interior wall of the casing and once completed they will run new packer and tubing in well and perform MIT test and once testing is complete they will start construction of pump house.
 +
|-
 +
| 2092464991
 +
| 2013-10-15
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that well is still idle and owner has submitted rebuild plan to the division and they are waiting on approval of plan.
 +
|-
 +
| 2100004227
 +
| 2016-01-06
 +
| Annular Disposal
 +
| No Violations
 +
| Injection pump was in operation on the day of my inspection.
 +
|-
 +
| 2102879171
 +
| 2015-12-29
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection revealed that injection pump was in operation on this day of my inspection.
 +
|-
 +
| 2130911311
 +
| 2015-05-18
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Stopped by service rig for update they are currently stuck in hole at 5380 we worked string and tubing became free and they were able to pump fluid around bit and continue to clean out wellbore.
 +
|-
 +
| 2133064485
 +
| 2017-03-14
 +
| Salt Water Injection Well
 +
| No Violations
 +
| Inspection today revealed that injection pump was in operation during my inspection.
 +
|-
 +
| 2143814339
 +
| 2018-03-11
 
| Salt Water Injection Well
 
| Salt Water Injection Well
 
| No Violations
 
| No Violations
 
| Inspection revealed that injection pump was in operation during my inspection and it was noted that one CS Trucking tanker was on site offloading during my inspection.
 
| Inspection revealed that injection pump was in operation during my inspection and it was noted that one CS Trucking tanker was on site offloading during my inspection.
 +
|-
 +
| 214838369
 +
| 2014-1-24 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 216435958
 +
| 2015-4-15 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 250911662
 +
| 2017-2-8 0:00:0
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 259846312
 +
| 2019-2-12 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 275102970
 +
| 2008-7-3 0:00:0
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 286257119
 +
| 2017-5-24 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 386632174
 +
| 2012-11-7 0:00:
 +
| PW
 +
| No Violations
 +
| 0.20
 +
|-
 +
| 387365330
 +
| 2008-6-2 0:00:0
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 395414581
 +
| 2015-10-1 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 427080007
 +
| 2017-2-22 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 429657617
 +
| 2017-8-24 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 434747279
 +
| 2015-9-25 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 451380060
 +
| 2007-6-5 0:00:0
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 458578328
 +
| 2016-5-31 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 468527408
 +
| 2019-6-17 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 479689203
 +
| 2015-11-17 0:00
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 480021501
 +
| 2015-1-5 0:00:0
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 48328763
 +
| 2005-1-6 0:00:0
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 495884058
 +
| 2016-9-7 0:00:0
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 528958761
 +
| 2018-4-2 0:00:0
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 5377227
 +
| 2002-8-13 0:00:
 +
| SW
 +
| No Violations
 +
| 1.00
 +
|-
 +
| 543784100
 +
| 2009-5-12 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 5604i102
 +
| 2002-3-19 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 5604i169
 +
| 2002-4-26 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 5604i206
 +
| 2002-5-9 0:00:0
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 5604i224
 +
| 2002-5-17 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 5604i225
 +
| 2002-5-21 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 5604i34
 +
| 2002-1-16 0:00:
 +
| WR
 +
| No Violations
 +
| 2.00
 +
|-
 +
| 5604i4
 +
|
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 5604i63
 +
| 2002-2-6 0:00:0
 +
| WR
 +
| No Violations
 +
| 1.00
 +
|-
 +
| 561435102
 +
| 2015-4-6 0:00:0
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 572190922
 +
| 2010-12-9 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 602395613
 +
| 2003-9-4 0:00:0
 +
| SW
 +
| No Violations
 +
| 2.00
 +
|-
 +
| 675004728
 +
| 2008-5-7 0:00:0
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 757321958
 +
| 2015-5-21 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 766214683
 +
| 2016-5-18 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 785092645
 +
| 2015-1-30 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 788205253
 +
| 2015-3-31 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 805768247
 +
| 2020-10-9 0:00:
 +
| SW
 +
| No Violations
 +
| 1.00
 +
|-
 +
| 923202239
 +
| 2009-1-5 0:00:0
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| 963406981
 +
| 2004-11-9 0:00:
 +
| SW
 +
| No Violations
 +
| 1.00
 +
|-
 +
| 970119835
 +
| 2015-1-10 0:00:
 +
| SW
 +
| No Violations
 +
| 4.00
 +
|-
 +
| 996504738
 +
| 2018-5-17 0:00:
 +
| SW
 +
| No Violations
 +
|
 +
|-
 +
| UIC1727
 +
| 1998-6-25 0:00:
 +
| SW
 +
| No Violations
 +
|
 
|-
 
|-
 
|}
 
|}
Line 2,003: Line 2,786:
 
  | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
 
  | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date =  2019-05-07
+
  | date =  2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
==References==
 
==References==
 
<references/>
 
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 
[[Category:Ohio Wells]]
 
[[Category:Ohio Wells]]

Latest revision as of 03:43, 12 January 2021

Well Details

Well ID: 34-121-23390
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Noble Township
Operator Name: CARPER WELL SERVICE INC.
Well Pad ID:
Farm/Lease Name: BRYAN-SMITH INC UNIT {SWIW #3}
License Status: Active Injection
License Date: 1987-11-20
Spud Date: 1984-12-19
Spud Drilling Contractor: MID ATLANTC DRLG
Final Drill Date: 1984-12-31
Well Total Depth: 5563.00 ft
Configuration: Vertical
Latitude: 39.770000
Longitude: -81.540000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-12-17 54 TITAN ENERGY CORP GeoDate 12/17/84
Oil and Gas 1984-12-17 Issued Date 12/17/84 Expired Date 6/15/85 Acres 0040490 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05563 Proposed Drill Depth 05563
Original Spud 1984-12-19
Completed 1984-12-31
Reached Total Depth 1984-12-31
Completion Report Received 1986-03-18
CO 1987-11-20 54 TITAN ENERGY CORP GeoDate 11/20/87
Conversion to Injector 1987-11-20
Salt Water Injection Well 1987-11-20 Issued Date 11/20/87 Expired Date 11/19/88 Acres 0040490 Tool Type RTA Proposed Formation CLINTON/MEDI Proposed Depth 00000 Proposed Drill Depth 00000
Storage Well 1987-11-20 Issued Date 11/20/87 Expired Date 11/19/88 Acres 0040490 Tool Type RTA Proposed Formation CLINTON/MEDI Proposed Depth 00000 Proposed Drill Depth 00000
First Injection 1988-10-11
Construction Permit Expires 1988-11-19
Annulus Pressure Monitoring Approved 1995-09-06
Change of Owner 1997-12-18 Operator changed from 54, TITAN ENERGY CORP to 4540, PEOPLES PETROLEUM CORP.
Change of Owner 2001-02-23 Operator changed from 4540, PEOPLES PETROLEUM CORP. to 3133, PETROEL
Change of Owner 2001-06-25 Operator changed from 3133, PETROEL to 7007, CARPER WELL SERVICE
Last Compliance Report 2010-03-29
Record Last Modified 2017-10-19

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2001-11-05 4603 4606 12
2000-05-05 5327 5447 1
5327 5447 1
4603 4606 12
4603 4606 12

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
FOAM 0 68000 Gal 40000 FRAC;H2O,SAND; ALSO INJECTED INTO MEDINA SS.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 WALHONDING ENERGY CO 3147.00 0.00 0
1986 WALHONDING ENERGY CO 656.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 WALHONDING ENERGY CO Brine 0 0
1986 WALHONDING ENERGY CO Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1032171774 2011-6-10 0:00: SW No Violations
-1036095644 2015-1-9 0:00:0 SW No Violations 6.00
-1100645896 2015-5-20 0:00: SW No Violations
-1202476629 2007-1-2 0:00:0 SW No Violations
-1207662360 2012-2-10 0:00: SW No Violations
-1211473851 2015-5-7 0:00:0 SW No Violations
-1230648854 2011-4-28 0:00: SW No Violations
-1252803534 2014-10-27 0:00 SW No Violations
-1254363886 2010-12-29 0:00 SW No Violations
-1274296236 2020-10-9 0:00: SW No Violations 1.00
-1296272525 2010-3-30 0:00: SW No Violations
-1305694384 2006-4-4 0:00:0 SW No Violations
-1351488117 2004-5-10 0:00: SW No Violations 2.00
-1376609958 2018-5-14 0:00: SW No Violations
-1384500063 2009-2-12 0:00: SW No Violations
-1417405530 2015-10-21 0:00 SW No Violations
-1419161005 2003-6-2 0:00:0 SW No Violations
-1428603162 2015-9-9 0:00:0 SW No Violations
-1432751271 2016-11-8 0:00: SW No Violations
-1435892970 2009-10-8 0:00: SW No Violations
-1450120219 2009-9-4 0:00:0 SW No Violations
-1455312752 2016-12-21 0:00 SW No Violations
-1475831093 2015-1-27 0:00: SW No Violations
-149493778 2015-12-16 0:00 SW No Violations
-1525433948 2011-9-14 0:00: SW No Violations
-1553522418 2020-1-15 0:00: SW No Violations
-1564672871 2015-1-8 0:00:0 SW No Violations
-1581297244 2008-4-2 0:00:0 SW No Violations
-1635545047 2005-12-8 0:00: SW No Violations
-1819170680 2007-5-3 0:00:0 SW No Violations
-1826454894 2015-1-7 0:00:0 SW No Violations 3.00
-1841534296 2016-3-24 0:00: SW No Violations
-1890846684 2004-10-18 0:00 SW No Violations 1.50
-1952207672 2020-5-15 0:00: SW No Violations
-2019628224 2005-2-4 0:00:0 SW No Violations
-2037920083 2014-12-10 0:00 SW No Violations
-2091704699 2020-4-23 0:00: SW No Violations
-2100004227 2016-1-6 0:00:0 AD No Violations
-2102879171 2015-12-29 0:00 SW No Violations
-210366979 2015-4-27 0:00: SW No Violations
-2130911311 2015-5-18 0:00: SW No Violations
-2133064485 2017-3-14 0:00: SW No Violations
-2143814339 2018-3-11 0:00: SW No Violations
-225655085 2005-9-23 0:00: SW No Violations
-288665557 2007-7-9 0:00:0 SW No Violations
-345539737 2007-2-6 0:00:0 SW No Violations
-371683144 2010-5-21 0:00: SW No Violations
-391155921 2017-8-29 0:00: SW No Violations
-435286527 2010-2-2 0:00:0 SW No Violations
-438810527 2015-2-2 0:00:0 SW No Violations 2.00
-440372304 2015-9-14 0:00: SW No Violations
-524935433 2008-12-4 0:00: SW No Violations
-53123739 2019-9-26 0:00: SW No Violations
-557678394 2014-10-30 0:00 SW No Violations
-585855735 2015-4-17 0:00: SW No Violations
-599281069 2011-3-26 0:00: AD No Violations 4.00
-620810822 2020-10-14 0:00 SW No Violations 6.00
-636816591 2018-12-27 0:00 SW No Violations
-678997720 2019-4-1 0:00:0 SW No Violations
-679021003 2015-4-2 0:00:0 SW No Violations
-708379192 2015-2-4 0:00:0 SW No Violations
-716431656 2014-10-29 0:00 SW No Violations
-759916444 2013-8-20 0:00: SW No Violations 1.00
-795119875 2008-10-2 0:00: SW No Violations
-809104420 2018-10-5 0:00: SW No Violations
-844377490 2013-12-13 0:00 SW No Violations
-85278170 2002-5-6 0:00:0 SW No Violations
-855505376 2007-11-16 0:00 SW No Violations
-87066765 2014-11-3 0:00: SW No Violations
-874994452 2005-6-1 0:00:0 SW No Violations 1.50
-938018689 2020-10-8 0:00: SW No Violations 4.00
-939477225 2009-11-3 0:00: SW No Violations
-987295990 2006-12-14 0:00 SW No Violations
00005604i4 Salt Water Injection Well No Violations
0005377227 2002-08-13 Salt Water Injection Well No Violations
0005604i34 2002-01-16 Work Over Reconditioning No Violations
0005604i63 2002-02-06 Work Over Reconditioning No Violations
000UIC1727 1998-06-25 Salt Water Injection Well No Violations 1501: 9-9-05 (10) IDENTIFICATION
001259i193 2002-10-30 Salt Water Injection Well No Violations
0048328763 2005-01-06 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Noted:Three Key Energy tankers unloading brine during my inspection. (11) Housekeeping needed in unloading area,stone needed in driveway area. Tank area in need of a good steam cleaning!

005604i102 2002-03-19 Salt Water Injection Well No Violations Cleaning Tanks Preparing to place well in service.
005604i169 2002-04-26 Salt Water Injection Well No Violations Hooking up pumps.
005604i206 2002-05-09 Salt Water Injection Well No Violations
005604i224 2002-05-17 Salt Water Injection Well No Violations 1st. Test on pipeline failed due to a well head leak. 2d. Test failed due to pipeline leak. New curb poured for loading pad.
005604i225 2002-05-21 Salt Water Injection Well No Violations Pipeline from pump to well tested at 1510psi. For 30min. Pressure did not drop. Test Approved.
0085278170 2002-05-06 Salt Water Injection Well No Violations operator working on unloading pad. Carper well service is the owner!
0087066765 2014-11-03 Salt Water Injection Well No Violations On site to witness rig operator pull tension on tubing string and then try and tighten up tubing head to stop small leak noted on previous inspection.
0114208207 2007-10-03 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Owner is in process of cleaning out storage tanks called his office and left message that I will need run tickets to verify proper disposal of tank waste.

0149493778 2015-12-16 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that two Ramco vacuum trucks were unloading at the facility on this day.
0174001850 2017-04-28 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation during my inspection.

Note: Weedeating needed in area of wellhead and flowline area.

0185563784 2006-05-02 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note:Operator is trying to clean up tank area(stills has a way to go) but is putting some effort into getting facility up into 21st Century industry standards. Walked flow line no leaks found.

0210366979 2015-04-27 Salt Water Injection Well No Violations Company owned service rig on well cleaning out wellbore they were at 5251 with bit and hope to have interior of casing cleaned out by early next week.
0214838369 2014-01-24 Salt Water Injection Well No Violations Inspection revealed that well is still down waiting on owner to submit rebuild plan for facility.
0216435958 2015-04-15 Salt Water Injection Well No Violations Inspection revealed that service rig was pulling tubing and milling tools from well bore to replace milling tool this one has stopped cutting up debris.
0225655085 2005-09-23 Salt Water Injection Well No Violations No violations noted ,facility appers to be in satisfactory condition this inspection.

Called well owner and stated that entire plumbing system at storage site is in need of being replaced due too fact that band clamps that they have in place are seeping,also noted that 210bbl storage tank is leaking from heater tube and is in need of being repaired or replaced,also told operator that entire tank area is in need of a good steam cleaning he stated he would start repairs 9/26/05 weather permitting.

0250911662 2017-02-08 Salt Water Injection Well No Violations On site to witness mini pressure test on annulus of tubing,injetion pup was in operation during my inspection.
0259846312 2019-02-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.


Note: Inside of tank area is in need of a good cleaning noticed trace amount of sheen in water within containment area.

0275102970 2008-07-03 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection

Note: Requested owner to replace 2 high pressure hose @wellhead the one in use is showing signs of defects.

0286257119 2017-05-24 Salt Water Injection Well No Violations Inspection today revealed that injection pump to this well was in operatin today and it was noted that one company owned tanker was unloading at the facility during my inspection.
0288665557 2007-07-09 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Pump was not in operation during my inspection, noted stainingon unloading pad apparently truck had a bad leak in valve during unloading procedure.House keeping needed in tank area operator needs to clean out tanks to allow for more for more volume of brine .

0345539737 2007-02-06 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Noted company owned tanker parked on unloading pad no truck attached,suggest placing tub under valve on tanker too catch salt water dripping from connections.

0371683144 2010-05-21 Salt Water Injection Well No Violations Inspection revealed that pump was in operation during my inspection.

Note: Area around wellhead is in need of restoration work preformed,area needs to be seeded&mulched to prevent eroision issues that might arise and road to wellhead is in need of stone.

0386632174 2012-11-07 Production Wells No Violations My inspection today finds that the well has 100 psi. on the 4.5 casing, and 280 psi. on the 2.375 tubing.
0387365330 2008-06-02 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Pump was not operating during my inspection also walked flow line area to monitor area for potential leaks none found, tank area has been somewhat cleaned sealant in cracks needs to be replaced (not what your using at present date its not oil/brine compatible!!

0391155921 2017-08-29 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation due to fact that Producers Services was on site performing 2000 gallon acid treatment on said well.
0395414581 2015-10-01 Salt Water Injection Well No Violations Inspection on this day indicated that injection pump was not in operation during my inspection and it was noted that owner was having new lighting installed at the facility.
0427080007 2017-02-22 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection.
0429657617 2017-08-24 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation and operating at maximum allowable pressure and it was noted that two company owned vacuum trucks were unloading at the facility during my inspection.
0434747279 2015-09-25 Salt Water Injection Well No Violations On site to do walkthrough with operator prior to placing well back into operation, all plumbing has been replaced and new 300 bbl. Tanks installed and new pump house has been constructed and once electrical work is completed owner will resume operations at this site.
0435286527 2010-02-02 Salt Water Injection Well Violations Noted Inspection revealed that well has equalizedcalled company and let them be aware of suspension order,call central office and requested order be issued for said well. Repair tubing /packer and properly perform required testing before placing well back into operation.

Failure to comply may result in bond forfeiture.

0438810527 2015-02-02 Salt Water Injection Well No Violations Inspection revealed that company owned service rig was pulling tubing from well and changing out bit and once they get cement retainer drilled up and they get below perforations they will pressure test casing for integrity.
0440372304 2015-09-14 Salt Water Injection Well No Violations Inspection on this day indicated that owner is nearly complete with rebuilding of facility and we pressure tested flow line to wellhead at 1400 psi with no pressure loss and I reminded owner that new identification needed to be posted on tanks and also wellhead.
0451380060 2007-06-05 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Pump was not in operation during my inspection,called well owner and suggested that they have well tender weedeat path to wellhead and steamclean tank area ASAP.

0458578328 2016-05-31 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today.
0479689203 2015-11-17 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during our inspection today.
0480021501 2015-01-05 Salt Water Injection Well No Violations Inspection on this day revealed that company owned service rig was running a test packer in well to locate possible hole in casing and once they pinpoint it they will perform cement squeeze job to repair casing.
0495884058 2016-09-07 Salt Water Injection Well No Violations On site to witness mini pressure test on annulus of tubing they applied 500 psi of pressure and we monitored it for 15 minutes with no decline in pressure.
0524935433 2008-12-04 Salt Water Injection Well No Violations Inspection revealed that pump was not in operation during my inspection.

Note:As weather permits housekeeping is needed in tank area also noted damp conditions around cleanout plate on several 210 bbl tanks suggest empty tanks and reseal cover plates.

0528958761 2018-04-02 Salt Water Injection Well No Violations Inspection revealed that there was no activity at the site during my inspection.
0543784100 2009-05-12 Salt Water Injection Well No Violations Inspection this day found Producers Service Co. acidizing injection well. Used 2000 gal. Of 15% acid and well taking it fairly easily.
0557678394 2014-10-30 Salt Water Injection Well No Violations Inspection revealed that concrete has been put in place and workers are proceeding along with getting well back into operation.
0561435102 2015-04-06 Salt Water Injection Well No Violations Stopped by service rig for update and they have retrieved bridge plug and now they are making site ready to go back in well and start drilling out cement retainer.

Note: Stopped at recently rebuilt containment area and tested water for chlorides none were detected after running quantab strip test.

0572190922 2010-12-09 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.

Note: Platform needs to be constructed at well head so inspector can properly remove gauge and monitor pressures at wellhead. Also noted that all storage tanks have been cleaned out and resealed and partially replumbed.

0585855735 2015-04-17 Salt Water Injection Well No Violations Inspection revealed that power swivel broke down and owner is currently making repairs on swivel and they will resume workover procedure within the next couple of days.
0599281069 2011-03-26 Annular Disposal No Violations Call from EMS in Noble Co. regarding a fire at disposal well south of Belle Valley. Responded to call, observed fire and the extingushing of it - took many pictures.
0602395613 2003-09-04 Salt Water Injection Well No Violations No violations noted,facility appears to be in good condition.

(3)oil tank still needs replaced (11)housekeeping needed in unloading area lease road to wellhead needs dressed up Suggest replacing hoses at unloading site (camlock ends are getting worn) Note:Walked flowline.

0636816591 2018-12-27 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation and it was noted that one company owned vacuum truck was offloading at the facility during my inspection.
0675004728 2008-05-07 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactor condition this inspection.

Note: Tank area is in need of a severe steam cleaning and trash dumpster is in need of repacement it has hole in bottom seeping residue from filter changes,also 2 nipple on elbow is in need of thread tape replacement@ wellhead.

0678997720 2019-04-01 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation during my inspection.

Noted one company owned vacuum truck on site during my inspection.

0679021003 2015-04-02 Salt Water Injection Well No Violations Service rig still on site attempting to remove bridge plug that was set in well bore they have gotten a hold of it and are coming out of the hole with it today.
0708379192 2015-02-04 Salt Water Injection Well No Violations On site to witness pressure test of 4.5 casing they pressured up to 1250 psi and we monitored pressure for 15 minutes with a 10# loss(TEST PASSED).
0716431656 2014-10-29 Salt Water Injection Well No Violations On site to witness crew place stone on exterior of containment wall to help strengthen it and on this day they formed up area for the new pump house and trash bin area and if weather permits they will place concrete tomorrow.
0757321958 2015-05-21 Salt Water Injection Well No Violations Timco on site to log well and possibly reperforate casing.
0759916444 2013-08-20 Salt Water Injection Well No Violations My inspection today revealed that the injection well is still shut down awaiting the owner to rebuild the tank facility and pump house, they had fire at facility a couple years ago.
0766214683 2016-05-18 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation and it was noted that one RAMCO bottle trucks was on site unloading during my inspection,
0785092645 2015-01-30 Salt Water Injection Well No Violations Stopped by service rig for update they were still drilling cement retainer out and operator stated that he could be ready to pressure test casing integrity tomorrow if they get hole cleaned up.
0788205253 2015-03-31 Salt Water Injection Well No Violations Company owned rig milling on bridge plug they hope to pull it from well later this week.
0795119875 2008-10-02 Salt Water Injection Well No Violations Inspection revealed that well was not in operation during my inspection, well tender was replacing plumbing on tubing head 2 high pressure elbow was replaced and other assorted fittings also, tank area is in need of a good cleaning while the weather is favorable.
0809104420 2018-10-05 Salt Water Injection Well No Violations On site to witness acid treatment job 2000 gallon of 28% HCL was pumped and ISIP was noted at 1107 and after 10 minutes it was noted at 896 psi Producers rigged down and job was deemed complete.
0844377490 2013-12-13 Salt Water Injection Well No Violations Inspection revealed that well is still down waiting on owner to submit rebuild plan to division.
0855505376 2007-11-16 Salt Water Injection Well No Violations Complaint called in from OHIO EPA(Dennis Deavers) of strong odor of sulfur smell near tank site,upon inspecting site found that operator had unloaded tanker truck prior to my inspection apparently source of smell derived from water source from unknown source in adjoining state, contacted well owner Millard Carper and discussed issues at well site, received several complaints from local citizens about odor told them smell would dissipate in time.
0874994452 2005-06-01 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Noted that partial cleanup in tank area has been preformed lots more to go! While preforming my inspection noted Arvilla truck unloading noticed tank was leaking called their company rep and requested that they get tank repaired ASAP.

0923202239 2009-01-05 Salt Water Injection Well No Violations Inspection revealed that pump was in operation during my inspection.

Note: Housekeeping needed in tank area and stone is needed around unloading pad area to help minimize tracking mud out onto state route.

0939477225 2009-11-03 Salt Water Injection Well No Violations Inspection revealed that pump was not in operation during my inspection,stopped at pumphouse and talked to well tender he stated that brine trucks have not been using facility recently,noted that tank area has been recently cleaned and facility appears to be in satisfactory condition this inspection.

Note: Stone is needed on road to wellhead.

0963406981 2004-11-09 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

(3)clean up needed in tank area (11)housekeeping needed in unloading pad area.

0970119835 2015-01-10 Salt Water Injection Well No Violations On site to witness Formation cementing pump on tubing which was set on packer placed in between perforations and once rate was established decision was made that they would perform squeeze job tomorrow.
0987295990 2006-12-14 Salt Water Injection Well No Violations No violations noted, facility appears to be in fair condition this inspection.

Noted oil within tank area called company and requested that they clean up oil within tank area ASAP,told them that steam cleaning would need to be preformed within tank area to ensure of no pollution&contamination violations arose from free standing oil also cracks in concrete in need of repair! Small oil stain noted beside of unlading pad area in need of clean-up!

0996504738 2018-05-17 Salt Water Injection Well No Violations Injection pump not in operation owner is currently having storage tanks cleaned out.
1015150122 2015-07-14 Salt Water Injection Well No Violations Inspection revealed that owner is still plumbing up new storage tanks and making preparations to start building new pump house facility
1018136326 2006-07-24 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory this inspection.

Noted: Pump was in operation on the day of my inspection,tank area in need of a good cleaning,cracks in concrete need to be resealed too ensure that no brine/oil can leach into the ground.

1022095659 2016-09-20 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation during my inspection and it was noted that one Evolution vacuum truck was unloading at the facility during my inspection.
1032171774 2011-06-10 Salt Water Injection Well No Violations Inspection revealed that owner is trying to remove old tanks and other waste from site,well is not in operation at this time due to fact of recent fire at tank facility.
1036095644 2015-01-09 Salt Water Injection Well No Violations Onsite to witness bond logging of well to determine where possible leak is in wellbore and then perforate casing and tomorrow squeeze cement across defected zone.
1036483126 2010-06-17 Salt Water Injection Well No Violations Stopped and checked on service rig for update on getting packed and tubing out of well, rig crew stated that they have to mix more calcium chloride to kill well before removing packer and tubing.
1042501551 2002-10-30 Annular Disposal No Violations Dike area needs house keeping done and unloading pad needs a good cleaning!

Also need to change 1/4 valve on discharge side of well head.

1042657927 2003-01-15 Salt Water Injection Well No Violations [5]Tank area needs a good cleaning
1042658777 2003-01-15 Salt Water Injection Well No Violations Tank area needs cleaned up.

UNLOADING AREA NEEDS HOUSEKEEPING!

1044473445 2003-02-05 Salt Water Injection Well No Violations Walked flow line appears to be O.K.

(5) General house keeping in tank area. (11)House keeping on unloading pad.

1047389421 2003-03-11 Salt Water Injection Well No Violations well equalized called Carper Well to shut down well

Called Tom Tomastik to get well shut down. (11)housekeeping in unloading area (3)tank area to be cleaned

1051625368 2003-04-29 Salt Water Injection Well No Violations On location to witness (Packer and tubing run in hole to 5220)due to supension order.4/30/03flush hole with30bbl fresh water and 5gal.inhibitor pressured tested well at 1230psi for 15min(pressure test passed)

suggest removing old flowline going to tank facility.

1052761827 2003-05-12 Salt Water Injection Well No Violations No violations noted on the day of my inspection.

(3)more clean-up needed in tank area (11)housekeeping in unloading area needs to get service pit reclaimed

1054989774 2011-04-01 Salt Water Injection Well No Violations On site with well owner and insurance investigators to discuss recent fire at tank site, they were trying to determine cause of fire and estimate cost of replacing tanks and pump house and injection pump if owner decides to rebuild facility.
1057420391 2003-07-03 Salt Water Injection Well Violations Noted (3)oil tank in dike area has seepage on bottom seam,suggest replacing tank.

(10)replace flowline to wellhead&remove all of old flowline (11)housekeeping needed in unloading pad area. Note:Contact inspector prior to putting well back into production after flowline is changed to pressure test new line.

1057751914 2003-07-08 Salt Water Injection Well No Violations preformed line pressure test on new flowline

tested line at 1230 psi for 1hr. Test passed.

1060274630 2003-08-04 Salt Water Injection Well No Violations No violations noted this inspection.

(3)suggest removing 100bbl.oil tank it appesrs to have small hole on bottom seam,also tank area needs a good steam cleaning. (11)general housekeeping in unloading area needed.

1065265869 2003-10-03 Salt Water Injection Well No Violations No violations noted,facility appears to be in good repair.

(3)housekeeping needed in tank area (11)housekeeping needed in unloading area Restoration still needed in wellhead area!

1071295029 2007-08-02 Salt Water Injection Well No Violations No violations noted ,facility appears to be in satisfactory condition this inspection.

Noted that injection pump has been replaced since my last inspection. Housekeeping is needed in unloading pad area it appears that customers tank valves leak during unloading process&also cleanup needed in tank area.

1071657513 2003-12-16 Salt Water Injection Well No Violations No violations noted,facility appears to be in satisfactory condition.

(3)Housekeeping needed in tank area. (11)Housekeeping needed in unloading area. Conversation with Milard Carper stated he was going to change out 100bbl oil tank within dike next wee

1073727983 2004-01-09 Salt Water Injection Well No Violations Facility appears to be in satisfactory condition on the day of my inspection.

(3)Housekeeping needed in tank area. (11)Housekeeping needed in unloading pad area. Note:100bbl oil tank still needs to be replaced.

1078490394 2004-03-04 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

(3)Clean up needed in tank area& old 100bbl tank that was removed from dike area needs to be hauled away. (11)Clean up needed in unloading area (4)area outside of dike needs to be addressed for cleanup.

1081207193 2004-04-05 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

(1)I.D. on tanks needs to be refreshed (3) tank area needs a good steam cleaning Triads water truck was unloading brine during my inspection UIC#310 driver Charlie Holly.

(11)housekeeping needed in unloading area Note:old 100bbl tank needs to be removed from site!

1087052252 2004-06-07 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

(3)Steam cleaning needed in tank area. (11)Housekeeping needed in unloading area.

1088984554 2004-07-01 Salt Water Injection Well No Violations Facility appears to be in satisfactory condition this inspection.

(1)Instructed operator to place proper I.D.at tank site,(3)Seggested to operator that clean is needed in tank area,told him failure to comply may result in suspension order. RWS Trucking was unloading during my inspectionUIC#317

1091977487 2004-08-04 Salt Water Injection Well No Violations No violations noted,facility appears to be in satisfactory this inspection.

(6)Replace1/4valve on tubing side of wellhead to allow inspector to check pressure. Customer ran storage tanks over suggested to well owner to steam clean tank area he agreed to do so.

1093169379 2004-08-20 Salt Water Injection Well No Violations No violations noted,facility appears to be in satisfactory condition this inspection.

(6) 1/4 needle valve on tubing side of wellhead needs changed.

1100645896 2015-05-20 Salt Water Injection Well No Violations Hole was cleaned out to 5501 and owner plans on logging well tomorrow and possibly start new tubing and packer in well next week.
1102177048 2004-12-03 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Housekeeping needed in tank area. Housekeeping needed in unloading pad area.

1111099522 2005-03-14 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

(3)Tank area in need of a good steam cleaning. Note:Walked flowline

1115482349 2005-05-04 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Well owner will need to preform clean-up within tank area(extensive steam cleaning). Failure to comply may result in suspension order. Energy Contractors vac truck on site but not driver could be located.

1129249585 2005-10-07 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Noted housekeeping has been preformed in tank area also new plumbing of piping system in place,cracks in concrete in need of being repaired. Suggest cleaning of inside of storage tanks to allow for more volume of brine storage!

1131718009 2005-11-07 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Noted: High pressure on annulus of tubing well operator stated that he liked to maintain high annulus pressure too help relieve pulsating tubing.

1136321763 2006-01-03 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactiry condition this inspection.

Pump not running during my inspection,housekeeping needed in tank area when weather permits.

1142032665 2006-03-08 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Housekeeping needed in tank area, when weather permits steam cleaning needed in said area.

Suggest having fire extinguishers checked and refill if needed also check first aid kit for ample supplies.

114208207 2007-10-3 0:00: SW No Violations
1149347793 2006-06-01 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Suggest placing stone on road to wellhead and housekeeping in tank area!

1155677242 2006-08-15 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Noted that right away for flow line has been mowed to allow inspector to walkflowline area,cracks in concrete in tank area still need to be repaired.

1158401092 2006-09-14 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note:Pump note in operation today noted that seals were out of transfer pump and hoses were leaking inside of pump house called well owner Milard Carper and requested that he replace faulty hoses and repair seal on transfer pump or replace entire pump,also noted that steam cleaning has not been preformed in tank area that was suggested on previous inspection.

1160128383 2006-10-04 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection, walked flow line too monitor for possible leaks none found) also noted that housekeeping is suggested in tank area cracks in concrete in need of being resealed to prevent escape of brine water into fresh water strata.
1164361592 2006-11-20 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Pump not running today,operator will need to perform housekeeping in tank area,small cracks in concrete in tank area still needs to be sealed up!weed eating on path of flow line needs preformed before weather gets too bad.

1173468844 2007-03-09 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection,pump was not operating during my inspection Energy Contractors tanker was unloading at facility talked to driver and suggested he replace valve on truck before returning to this facility he stated he would tell supervisor when he returned truck to Weston WVA.Also called and talked to well owner concerning cleanup needed within tank area he stated that a valve had froze up and busted allowing small amount of oil to seep out within tank area.
1175641067 2007-04-02 Salt Water Injection Well No Violations No vioolations noted facility appears to be in satisfactory condition this inspection.

Noted that well owner is attempting too repair cracks in concrete in tank area still has quite a bit of work to do before all cracks are sealed,suggest replacing 1/4 valves on wellhead the ones in place are getting hard to work!,stone is needed on road to wellhead.

1189721624 2007-09-10 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.
Note: Pump was not operating during my inspectin,walked flow line area to monitor for leaks (none found) owner needs to clean up within tank area,noted possible seepage on two 210 bbl tanks will monitor as needed if  seepage worsens will request owner remove&replace tanks.
1194259204 2012-11-07 Salt Water Injection Well No Violations Inspection revealed that facility is still down awaiting repairs to storage facility and pump house replacement and electrical services restored at site.
1194388911 2007-11-02 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Pump was in operation during my inspection, also noted that well owner is in process of cleaning out storage tanks,noted waste container placed on unloading pad it appeared that operator has been placing sludge in container and shiping it to a approved EPA landfill.

1195731531 2007-11-20 Salt Water Injection Well No Violations On site to witness clean-up efforts made by well owner,crew was steam cleaning tank area as suggested by inspector too help eliminate foul odor at unloading site,monitored H2S meter near tanks detected 6ppm during inspection,pump was in operation during inspection.
1195843018 2007-11-21 Salt Water Injection Well No Violations Complaint made by Susan@AbabbellasRestaurant of foul odor wants something doneabout it,told her that smell would disapate with timeran monitor around location no H2S detected,crew was on site steam cleaning tank area trying to avoid any more complaints from local citizens,suggested they have local refuge hauler come and empty dumpster(old filters and filter sacks were in it and odor was detected.
1196722381 2007-12-03 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Pump was in operation during my inspection, walked flow line area to monitor area for potential leaks( none found),small trace of H2S odor detected on south side of storage tank area,storage tanks on south side of facility needs to be emptied and tanks properly cleaned!!!!!.

1199308204 2008-01-02 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Pump was not in operation during my inspection, well tender stated he had just shut pump down prior to my arrival.

1202476629 2007-01-02 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Pump was not running during my inspection noted operator has cleaned up oil within tank area since my last inspection but cracks in concrete still needs to be sealed.

1202769405 2008-02-11 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Clean-up needed in tank area,it appears that operator ran oil tank over and it is a mess within tank area, suggest that owner steam tank area as soon as weather permits also have well operator keep a better eye on tanks and not let them run over!!!!!!!.also clean up is needed in wellhead area it appears that tubing head packing has leaked a little since my last inspection.

1204580759 2008-03-03 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Cleanup in tank area needed,tanks need cleaned and steamed,pump was in operation during my inspection also walked flow line area to monitor for potential leaks none found).

1207662360 2012-02-10 Salt Water Injection Well No Violations On site to met with landowner and well operator to discuss issues with getting well back into operation it was agreed upon that dike walls will be replaced and pump location be mover outside of tank area and road to wellhead will be stoned before going into operation and fire suppression system be in place also.
1211473851 2015-05-07 Salt Water Injection Well No Violations Inspection revealed that company owned service rig on site preparing to trip out tubing and mill tomorrow.
1217350529 2003-04-14 Salt Water Injection Well No Violations Stopped by service rig for update they were getting ready to pull defected tubing out of hole.
1217886805 2008-08-04 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Pump was in operation during my inspection, walked flow line area to monitor area for potential leaks none found),also noted three company owned vac trucks unloading at facility during my inspection ,talked to well tender concerning leaking fittings on unloading plumbing he stated he would have bad fittings replaced by days end.

1220729098 2008-09-04 Salt Water Injection Well No Violations Pump not in operation today,unloading pad is in need of a good cleaning and tank area alsois in needof a steam cleaning.
1226417143 2008-11-10 Salt Water Injection Well No Violations Inspection revealed that well was not in operation during my inspection,after talking to well tender stating that well has been down for pump repair,noted that H&L Oilfield Services vac truck was unloading at site during my inspection,told well tender thhat cleanup in tank area was needed he stated that he would let well owner know that work is neededd in tank area.
1230648854 2011-04-28 Salt Water Injection Well No Violations Inspection revealed that injection pump has been removed from site of recent fire at facility,adjacient land owner called and voiced concerns if owner was planning on reopening well for commercial use.
1236212068 2009-03-04 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today,welll tender stated that mainitence work in pump house was to be preformed today,called owner and discussed getting stone for facility and getting tank area steamed cleaned in the near future.
1250073390 2009-08-11 Salt Water Injection Well No Violations Inspection revealed that well was not in operation today,instructed well tender to install new 1/4 needle valve on tubing old one is showing signs of leakage.Also inquired about getting belt guard installed on injection pump pulley,in its present state ther is a safety issue.
1252803534 2014-10-27 Salt Water Injection Well No Violations Stopped by well site to check on work crew that is making upgrades to facility.
1254363886 2010-12-29 Salt Water Injection Well No Violations Inspected site along with supervisor and inspection revealed that pump was in operation today.

Note: Platform at wellhead is needed so inspector doesnt have to climb on tubing head to place gauge on and more cleanup around wellhead is needed there is still old pit liner and lumber that needs to be removed from site and as weather permits vegetation needs to be established in area of old working pit.

1257841499 2004-02-10 Salt Water Injection Well No Violations No violations noted facility appears to be in good repair.

(1)tank I.D.needs refreshed (3)extensive cleaning needed in tank area (11)housekeeping needed in unloading pad area Note:old 100bbl oil tank needs removed from site!

1259i193 2002-10-30 0:00 SW No Violations
1265755723 2010-02-09 Salt Water Injection Well No Violations Well down for repair, injection pressure and annulus pressure equalized .Talked to well owner Millard Carper and suggested that he bleed off pressure on backside of tubing then reapply pressure and I would monitor it for compliance.
1268771824 2010-03-16 Salt Water Injection Well No Violations Stopped by well site to check on rig ,they were mixing Calcium Chloride to weight up water to kill well so they could pull tubing and then go in well to drill up cement retainer and then run new packer assembly in well and if all goes good place well back into operation.
1269124297 2010-03-19 Salt Water Injection Well No Violations Stopped by service rig for update,rig crew was rigging up power swivel and mud pump in preparation to drill out cement retainer.3/20/2010 Rig operator called and stated they had drilled up retainer and possibly will be ready to run packer and tubing in well 3/22/2010.
1269296520 2010-03-22 Salt Water Injection Well No Violations On site to witness rig operator start new Patriot Packer in hole, will continue to run the rest of tubing 3/23/10 and pressure test annulus of tubing if Packer passes required testing.
1269389403 2010-03-23 Salt Water Injection Well No Violations On site to witness rig crew run tubing and set packer@5165 informed owner that he would be required to request variance on packer setting depth because they are not within 100 of top perf,called Central Office and talked to UIC supervisor regarding setting depth of packer.

Note: Packer is equipped with down hole shut off valve and setting depth is 5165 Patriot model T 607.

1271368944 2010-04-13 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.

Note: Called company in reguards too restoration work needed at site,area needs to be seeded and mulched to help prevent erosion issues at site and old plastic pit liner needs to be properly disposed of.

1275050552 2017-12-28 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and operating at maximum allowable pressure and in conversation with operator stating that they were receiving flowback water at this time.
1275517476 2010-06-02 Salt Water Injection Well No Violations Inspection revealed that well has equalized, called company and requested that they repair well, they stated that they would have service rig on well within the next couple days and they would pull tubing and packer and inspect element on packer and check for possible hole in tubing.
1276901772 2010-06-18 Salt Water Injection Well No Violations Stopped by service rig for update they were attempting to kill well in preparation to pull tubing and packer, rig operator called and stated they had removed tubing and packer from well and would attach swedge and valve to casing and shut it in for the weekend .
1277672162 2010-06-26 Salt Water Injection Well No Violations On site at request of well owner too witness running of tubing and packer in hole to test for integrity of casing and tubing, arrived on site and witnessed rig operator run casing scrapper in hole to remove scale and any other obstruction that might hinder setting of packer element. Operator was unable to start running packer and tubing due to fact well was still flowing back told them to get well killed and once they reached that point call Inspector so he can come to site and witness running of tubing and packer in well.
1277672809 2010-06-27 Salt Water Injection Well No Violations Rig operator called and stated they were ready to run tubing and packer into well,upon arriving on site it was determined that well was not static decision was made to mix more kill fluid and try again tomorrow.
1277766028 2010-06-28 Salt Water Injection Well No Violations Onsite to witness operator run tubing and packer in well,setting depth was 5198.30 pressured up on annulus to 1270 psi and monitored pressure for 15 min pressure declined to 980 psi at end of test (TEST FAILED) will attempt to move packer up hole 8 tomorrow and retest.
1278154931 2010-07-02 Salt Water Injection Well No Violations Stopped by service rig for update on trying to repair casing they think that 4.5 possibly has hole in it above cement top is estimated to be@approximatly 900 according to E-logs at site, will continue to monitor well site for compliance.
1279309367 2010-07-13 Salt Water Injection Well No Violations On site to witness rig operator run 1.5 tubing down backside of production casing and tag cement top and then pump cement slurry in casing to seal off any potential leakage in 4.5 casing, will retest annulus of tubing string and packer integrity in near future.
1283288298 2010-08-31 Salt Water Injection Well No Violations Stopped but service rig for update on running packer and tubing back in well too test for casing integrity and to flush annulus of tubing and add fresh water and inhibitor to backside of tubing if testing indicates that we have good integrity.

Note: Owner will possibly want to set packer at higher depth in hole, suspects faulty casing at old setting depth.

1284161485 2010-09-10 Salt Water Injection Well No Violations Inspection revealed that well is not in operation at this time, on site to witness rig crew mix kill water and then packer rep attempted to release packer and set at higher depth, packer was released and we moved packer up hole one joint at a time and attempted pressure test, once we reached 5006 and packer would not set decision was made to pull packer from well and have packer rep rebuild it and we will run it back in hole as soon as it is delivered back to well site.
1285196310 2010-09-22 Salt Water Injection Well No Violations Stopped by well site to check on service rig crew, they were mixing calcium chloride in attempt too kill well and possibly start new packer in hole.
1293304785 2011-05-09 Salt Water Injection Well No Violations Stopped by site to check on fluid level in dike area there was approximatly 6 of fluid in dike with very low brine content it will need to be removed from dike and hauled to another disposal well.
1296272525 2010-03-30 Salt Water Injection Well No Violations Stopped by well to check on injection pump for leakage after start up at facility,none detected.

Note: Pit at wellhead needs to be emptied ASAP and area restored and seeded and mulched to help prevent erosion at wellsite.

1298254422 2013-09-13 Salt Water Injection Well No Violations Inspection revealed that well is still down awaiting on work over plan to be approved by Central Office.
1301171506 2011-03-26 Salt Water Injection Well No Violations Received call from Com Center of tank fire south of Belle Valley on state route 821,investigated site and found that fire started in pump house area and then spread to tank area and all tanks and pump house were a total loss, two 210 bbl tanks erupted and landed on adjacent building and one landed in parking area, there was 6 fire departments responded and one officer from parks and one officer from wildlife were also on scene and three Noble county law enforcement officers were also present.

Once fire was put out and site evaluated it was determined that no brine/oil had escaped from dike area and I told well owner to remove all fluids from dike area and empty all remaining tanks at site and haul to another disposal well, will check on situation tomorrow.

1301240842 2011-03-27 Salt Water Injection Well No Violations Inspected site to check on compliance of inspectors directions of removing brine from dike area and too also check on any potential tank leakage none noted and all but two storage tanks have been emptied and they will be hauled out tomorrow and taken to another disposal well will check back in on site at later date to check up on clean up detail.
1301519834 2011-03-30 Salt Water Injection Well No Violations Visited site along with supervisor and we discussed events of recent fire at site and it was determined that if owner decides to rebuild facility concrete dike will need to be replaced not repaired.
1304716629 2011-05-05 Salt Water Injection Well No Violations Inspection revealed that well is not in operation due to fact of recent fire destroying injection pump and tank facility and dike area.
1305694384 2006-04-04 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note:Tank area in need of severe cleaning as soon as weather permits,also stone needed on lease road to wellhead,weedeating needed in area of flow line to wellhead.

1310603768 2011-07-13 Salt Water Injection Well No Violations Inspection revealed that well is still down for repair, several storage tanks have been removed from dike area there is three remaining tanks within dike 1-210 bbl and 2-100 bbl tanks it appears that owner is planning on cleaning up area within dike and possibly rebuilding injection facility.
1314994147 2011-08-31 Salt Water Injection Well No Violations Inspection revealed that well is out of service due to fact that tank site and pump house burnt up in recent fire at facility, water within tank area needs to be removed and weeds going to wellhead need to be cut and if well is going to be repaired unloading pad and tank site will need to be moved to a new location.
1316122404 2011-09-14 Salt Water Injection Well Violations Noted Inspection revealed that well is not in operation and has been idle for several months, tank area has water build up and needs to be hauled to another disposal facility.

Plug or put well back into operation after relocating unloading pad and tank and pump house areas. Failure to comply may result in bond forfeiture.

1323379584 2011-12-08 Salt Water Injection Well No Violations Inspection revealed that there has been no change in status of well it still remains idle and owner has made no attempts to place well back into operation.
1332629825 2012-03-23 Salt Water Injection Well No Violations Inspection revealed that well is not in operation at this time, owner is trying to make a deal with another operator to take over well and place back into operation.
1333834625 2012-04-06 Salt Water Injection Well No Violations Well is down for repair and replacement of tanks and injection pump and upgrades being made too facility.
1339110616 2012-06-04 Salt Water Injection Well No Violations Inspection revealed that well is still down for repair, it was noted that all old storage tanks have been removed from site and it was also noted that vault in unloading pad has been emptied.
1351488117 2004-05-10 Salt Water Injection Well No Violations No violations noted,facility appears to be in satisfactory condition this inspection.

(3)housekeeping needed in tank area(steamed cleaned) (11)housekeeping needed in unloading area.

1363030194 2013-03-11 Salt Water Injection Well No Violations Inspection revealed that injection well is still down awaiting on owner to rebuild tank facility and pump house, they had fire at facility a couple years ago.
1376609958 2018-05-14 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today due too fact they are preparing to have all of there storage tanks cleaned out.
1384500063 2009-02-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection, noted that storage tanks had run over all spillage was contained within dike ,talked to well tender and suggested that they have tanks cleaned as soon as weather permits.

Note: STONE IS NEEDED AROUND FACILITY TO HELP KEEP MUD FROM ENTERING HIGHWAY!!!!!!

1389820083 2014-01-15 Salt Water Injection Well No Violations Inspection revealed that well is still down waiting on plan to be submitted to rebuild facility to current industry standards.
1398286402 2014-04-23 Salt Water Injection Well No Violations Inspection revealed that well is still down awaiting on rebuild plan to be submitted to Central Office.

Note: Called company and requested that they have positive pressure applied to annulus of tubing.

1400017013 2014-05-13 Salt Water Injection Well No Violations Inspection revealed that well is still down waiting on owner to rebuild facility.

Note: On site along with Ryan Carper to pressure test annulus of tubing he applied 1000# of pressure and we monitored it for 15+ minutes with no decline in pressure.

1407867614 2014-08-12 Salt Water Injection Well No Violations Inspection revealed that well is still down waiting on owner to repair well or sell it to a responsible owner.
1409215036 2016-07-21 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
1414002865 2014-10-22 Salt Water Injection Well No Violations Inspection revealed that Crescent Supply crew is on site placing felt padding in dike area and once it is in place they will place 60 mil liner in place and spot storage tanks after that point.
1415357458 2014-11-05 Salt Water Injection Well No Violations On site to witness rig crew pull tension on tubing string and then tighten up tubing head to try and fix small leak noted on it on my last inspection after they tightened it up they applied pressure and we noticed another small leak we will retighten it later this week and retest it.
1415472044 2014-11-07 Salt Water Injection Well No Violations On site to witness owner attempt to pressure test annulus of tubing after they made repairs to tubing head they pressured up to1275 and we monitored pressure for 15 minutes and at the end of test period pressure had dropped too 900 psi and test failed and owner stated that they would try and pull more tension on packer and retry test on Monday.
1416254682 2014-11-17 Salt Water Injection Well No Violations Owner called and stated that rig crew would be on site this morning to release packer and pull from well, arrived on site but rig crew did not show up as planned called company office to inquire about crew and they stated that crew got hung up in snow storm in WVA.
1417300588 2014-11-28 Salt Water Injection Well No Violations On site to witness company rig release packer and start it out of hole.
1417405530 2015-10-21 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today.
1419161005 2003-06-02 Salt Water Injection Well No Violations No violations noted

(3)replace oil tank in tank area,appears to be seeping on bottom seam. (10)clean-up needed around flowline area (12)Better restoration needed on pit area(seed+mulch needed)

1419620526 2014-12-23 Salt Water Injection Well No Violations Inspection revealed that service rig is still on site and owner is waiting on new tubing and packer to be delivered to site and once it is here they plan on running it into well and then perform required pressure testing.
1420062416 2014-12-29 Salt Water Injection Well No Violations On site to witness company owned service rig start new packer and used 2.375 tubing run into well.

Note: Old setting depth was 5072 and there is still a cement retainer in the well bore at 5220 and I told owner if they plan on fixing well they would need to drill out the retainer and then clean out hole to total depth. Packer was equipped with on/off valve and also on/off tool we tried to set packer several times and pressure test with no positive test results at this time they will move packer assembly up hole tomorrow and try and retest.

1420066540 2014-12-30 Salt Water Injection Well No Violations Tested casing at 5078 and test failed tested again at the following depths5032,5015 ,5007 and they also failed pressure test the rig crew shut down for the night and will resume testing tomorrow.
1420134575 2014-12-31 Salt Water Injection Well No Violations On site to witness releasing of packer and pressure testing of tubing and rig crew pulled packer up to a depth of 3272 and casing pressure tested OK and then they dropped down too 3380 and pressure tested again and it was still OK and decision was made to further test casing integrity at deeper depths on 1/5/15.
1421091228 2015-01-11 Salt Water Injection Well No Violations On site along with Formation Cementing to witness cement squeeze job on defected casing they pumped 20 sacks of Class A cement and then rig crew pulled setting tool up above cement calculated top and then they pressured up on casing and well was shut in for the night and rig crew will remove tubing tomorrow and then make plans on drilling cement out from within casing and then we will pressure test casing.
1422998068 2015-02-03 Salt Water Injection Well No Violations Inspection revealed that service rig was still milling on cement retainer at 3377 and they should be ready to pressure test tomorrow.
1423598499 2015-02-08 Salt Water Injection Well No Violations Inspection revealed that company owned service rig was still trying to retrieve plug from inside of casing and after talking to packer hand decision was made to go in hole with wash over pipe and clean up around on/off tool and then run overshot in hole and attempt to get retrievable plug from well.
1428603162 2015-09-09 Salt Water Injection Well No Violations Inspection on this day indicated that owner has completed upgrades to dike area it now measurers 59x59 inside diameter and dike walls are 60 tall with a capacity of 3091 bbl. And there is 8-300 bbl. tanks connected and 2-210 bbl. Oil tanks within dike area and new pump house is going to be delivered in the next couple of days and then electrical work will begin and owner is planning on being in operation by the end of the month.
1432751271 2016-11-08 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation and well is currently operating at maximum injection pressure allowable.
1433021635 2005-04-06 Salt Water Injection Well No Violations No violations noted facility appears to be in satisfactory condition this inspection.

Tank area in need of extensive steam cleaning. More stone needed in unloading area.

1435513803 2015-06-25 Salt Water Injection Well No Violations On site to witness owner spot 8-300 bbl tanks within dike area and they will place 1-210 bbl oil tank in place and then begin to plumb them up and pump house will be built in the near future and owner is going to raise dike wall by 24 to allow for calculated volumes of required storage capacity when done dike wall will be approximately 40 high.
1435892970 2009-10-08 Salt Water Injection Well No Violations Inspection revealed that well is in operation pump was running on the day of my inspection.

Note: Hose on filter housing is in need of replacement it is showing signs of leakage.

1450120219 2009-09-04 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today,on my last inpection I requested that belt guard be installed on pump owner has not completed task as of this inspection,also noted that clean up in tank area is needed and unloading pad area needs steam cleaned also.
1454353876 2016-02-01 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.
1455039776 2016-02-09 Salt Water Injection Well No Violations Injection pump was not in operation today and in conversation with well tender they have not seen any trucks today.
1455312752 2016-12-21 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation and one company owned vacuum truck was unloading at he facility during my inspection.
1457558328 2016-03-07 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
1472562624 2016-08-30 Salt Water Injection Well No Violations On site to witness Producers Well Services perform 1000 gallon acid treatment on said well.
1475831093 2015-01-27 Salt Water Injection Well No Violations Inspection revealed that rig crew was drilling cement out from within casing and once they get cement drilled out we will pressure test casing for integrity before they drill up the bridge plug.
1476384583 2016-10-13 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation and it was noted that injection pump was operating at maximum pressure allowed and in conversation with well attendant stating that they were receiving flow back only at this time and I warned them not to exceed maximum allowable pressures.
1485376298 2017-01-25 Salt Water Injection Well No Violations Pressures were recorded prior to acid treatment, Producers Services on site to perform 1000 gallon acid treatment on said well they pumped 500 gallon of 28% then displaced into formation and they let it soak for 30 minutes and then they pumped another 500 gallon of 15% acid and then displaced it into formation and owner is going to let acid soak overnight before pacing well back into operation.

Note: Two UIC staff members from central office were on site to witness acid treatment job today.

1500924787 2017-07-24 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation and it was noted that one company owned tanker was unloading at the facility during my inspection.
1509130040 2017-10-27 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation during my inspection and it was noted that well is currently operating at maximum allowable pressure.
1512595831 2017-12-06 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation and it was noted that one CS Trucking vacuum truck was unloading at the facility during my inspection.
1523385418 2018-04-09 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation and it was noted that one Monroe Drilling vacuum truck was offloading at the facility during my inspection and it was noted that proper identification was missing from truck told driver and also called truck owner that truck must be properly identified before they haul any more brine.
1525433948 2011-09-14 Salt Water Injection Well No Violations FOLLOW UP TO NOV # 1316122404 Inspection revealed that well is not in operation and has been idle for several months. Tank area has water build up that needs to be hauled to another disposal facility. Plug or put well back into operation after relocating unloading pad and tank/pump house areas. Failure to comply may result in bond forfeiture.
1526054504 2018-05-11 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and one company owned vacuum truck was on site during my inspection.
1529248713 2018-06-13 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation and it was noted that two company owned vacuum trucks were offloading at the site during my inspection.
1532041234 2018-07-17 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and according to well operator injection pump has not run since last week.


Note: Two company owned vacuum trucks were offloading at the facility during my inspection.

1532367729 2010-08-05 Salt Water Injection Well No Violations Inspection revealed that service rig is still rigged up on well and crew is trying to determine if production casing has a hole in it and it was stated that they thought new packer element was not holding properly and that a new packer had possibly been ordered.
1542831200 2018-11-21 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.

Note: Informed owner that unloading pad area is in need of a good cleaning.

1549914798 2019-02-11 Salt Water Injection Well Violations Noted The Division has not received the 4th quarter brine disposal fees for 2018. Please forward disposal fees and sheets to the Division by 3/12/2019.
1563722676 2019-7-19 0:00: SW No Violations
1564672871 2015-01-08 Salt Water Injection Well No Violations No activity at site today due too extreme cold weather conditions.
1581297244 2008-04-02 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Pump was not in operation during my inspection also noted that new 2 check valve has been installed at wellhead since my last inspection, also noted that tank within dike has been run over since my last inspection steam cleaning tank area is highly advised and reseal cracks in concrete to ensure proper integrity of tank area.

1587417154 2020-4-20 0:00: SW No Violations
16158636 2020-10-13 0:00 SW No Violations 4.00
1618385507 2018-08-16 Salt Water Injection Well No Violations Inspection today indicated that injection pump was down for repair, operator stated that parts were in route and they hoped too be up and in operation later today.
1635545047 2005-12-08 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection,noted that replumbing of piping at facility has been completed.

Housekeeping in tank area needed as weather permits.

1650270922 2016-04-12 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation and in conversation with well attendant stating that they were receiving fluids from Flex Water facility and various sites from Eclipse Resources at the present time.
1676197129 2018-08-20 Salt Water Injection Well No Violations Cleaning off unloading pad today with steam cleaner/power washer.
1683461129 2005-07-13 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

During my inspection noted Energy Contractors truck unloading at site noted faulty 3valve on vac truck instructed driver to replace valve before returning to well. Need path to wellhead weedeated in area of flowline,cant properly inspect line when it buried in tall weeds.

174001850 2017-4-28 0:00: SW No Violations
1771712023 2020-8-14 0:00: SW No Violations
1791113881 2005-08-08 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Conversation with well owner concerning cleaning of storage tanks told him that all waste from tanks needed to be hauled to EPA approved landfill closest on around is located in Brownville Oh.

1819170680 2007-05-03 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection..

Note: Pump was running during my inspection,weed eating needed along flow line area and around wellhead!!!!!!,also housekeeping needed in tank area&tank area also.

1824766083 2007-11-23 Salt Water Injection Well No Violations Stopped by well site and check on cleanup and monitor air quality o2 level 20.9 north side of tanks no H2S detected 20.6 inside of pump house slight H2S odor detected would not register on gas meter,told well tender to call owner and have injection pump worked on #2&3 cylinders are in need of repair or replacement noted leakage on both.Contacted well owner and suggested he have pump worked on ASAP he agreed,picked up ticket for water they received 11/13/07 from BOBCAT OIL&GAS,Wayne WVA.suspect that was site of foul smelling water received at well site.
1826454894 2015-01-07 Salt Water Injection Well No Violations My inspection today finds the casing is being tested for holes. Carper Well Service is using a packer to test the 4.5 casing. The holes appear to be between 3380 and 3420.
1841183360 2017-06-02 Salt Water Injection Well No Violations Inspection revealedthat injection pump was in operation and it was noted that flowline area and wellhead area has been recently mowed and looks good.
1841534296 2016-03-24 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and it was stated by operator that they have not run injection pump since the first part of the week.
1852116223 2011-05-19 Salt Water Injection Well No Violations On site with Tom Tomastik to inspect well site.

Note: Tom confirmed with my findings that entire dike facility needs to be replaced before placing well back into operation.

185563784 2006-5-2 0:00:0 SW No Violations
1865560157 2019-03-06 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation during my inspection.
1872303264 2014-07-22 Salt Water Injection Well No Violations Inspection revealed that well is still down waiting on owner to start rebuilding process.
1882426079 2020-2-20 0:00: SW No Violations
1886853626 2010-01-20 Salt Water Injection Well No Violations Inspection revealed that pump was in operation today, noted H&L Water was unloading at facility during my inspection.

Note: Unable to check tubing pressure due to fact there was ice in valve, stopped at pump house and suggested too operator that they thaw out valve and place 1/4 plug in it to insure that valve is working properly.

1890846684 2004-10-18 Salt Water Injection Well No Violations No violations noted, facility in satisfactory condition this inspection.

Pump not running today. Housekeeping needed in tank area.

1912702274 2004-09-14 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

(6) Need to replace 1/4 valve at wellhead (tubing pressure side).

1919132471 2015-11-27 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that one Ramco vacuum truck was unloading at the facility during my inspection.
1922802762 2015-06-08 Salt Water Injection Well No Violations MIT test passed well is capable of injecting fluid and this resolves previous compliance notice issued.
1928889728 2010-06-16 Salt Water Injection Well No Violations Stopped by service rig too check and see if they had well killed and were ready to release packer and pull tubing, they were still mixing calcium chloride to get fluid weight to 12.5+ so well would become static and then they would release packer and pull tubing.
1956712549 2003-11-18 Salt Water Injection Well No Violations No violations noted,facility appears to be in good repair.

(3)Clean-up needed in tank area! 100bbl oil tank needs to be replaced. (11)Housekeeping needed in unloading area. (12)Restoration still needed aronnd wellhead.

1969386471 2006-02-13 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

Note: Pump was running on the day of my inspection,walked flowline. Could use some stone on lease road to wellhead! Tank area needs steamed cleaned as soon as weather permits.

1979004610 2018-05-04 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.
200022468 2020-5-4 0:00:0 SW No Violations
2006298469 2019-9-5 0:00:0 SW No Violations
2019628224 2005-02-04 Salt Water Injection Well No Violations No violations noted, facility appears to be in satisfactory condition this inspection.

(3) Housekeeping needed in tank area. (11) Area around unloading pad in need of stone to help from tracking mud onto state highway when truck are leaving site.

2037920083 2014-12-10 Salt Water Injection Well No Violations Company rep on site with swab rig to run casing scrapper in well and clean up the interior wall of the casing and once completed they will run new packer and tubing in well and perform MIT test and once testing is complete they will start construction of pump house.
2092464991 2013-10-15 Salt Water Injection Well No Violations Inspection revealed that well is still idle and owner has submitted rebuild plan to the division and they are waiting on approval of plan.
2100004227 2016-01-06 Annular Disposal No Violations Injection pump was in operation on the day of my inspection.
2102879171 2015-12-29 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation on this day of my inspection.
2130911311 2015-05-18 Salt Water Injection Well No Violations Stopped by service rig for update they are currently stuck in hole at 5380 we worked string and tubing became free and they were able to pump fluid around bit and continue to clean out wellbore.
2133064485 2017-03-14 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation during my inspection.
2143814339 2018-03-11 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that one CS Trucking tanker was on site offloading during my inspection.
214838369 2014-1-24 0:00: SW No Violations
216435958 2015-4-15 0:00: SW No Violations
250911662 2017-2-8 0:00:0 SW No Violations
259846312 2019-2-12 0:00: SW No Violations
275102970 2008-7-3 0:00:0 SW No Violations
286257119 2017-5-24 0:00: SW No Violations
386632174 2012-11-7 0:00: PW No Violations 0.20
387365330 2008-6-2 0:00:0 SW No Violations
395414581 2015-10-1 0:00: SW No Violations
427080007 2017-2-22 0:00: SW No Violations
429657617 2017-8-24 0:00: SW No Violations
434747279 2015-9-25 0:00: SW No Violations
451380060 2007-6-5 0:00:0 SW No Violations
458578328 2016-5-31 0:00: SW No Violations
468527408 2019-6-17 0:00: SW No Violations
479689203 2015-11-17 0:00 SW No Violations
480021501 2015-1-5 0:00:0 SW No Violations
48328763 2005-1-6 0:00:0 SW No Violations
495884058 2016-9-7 0:00:0 SW No Violations
528958761 2018-4-2 0:00:0 SW No Violations
5377227 2002-8-13 0:00: SW No Violations 1.00
543784100 2009-5-12 0:00: SW No Violations
5604i102 2002-3-19 0:00: SW No Violations
5604i169 2002-4-26 0:00: SW No Violations
5604i206 2002-5-9 0:00:0 SW No Violations
5604i224 2002-5-17 0:00: SW No Violations
5604i225 2002-5-21 0:00: SW No Violations
5604i34 2002-1-16 0:00: WR No Violations 2.00
5604i4 SW No Violations
5604i63 2002-2-6 0:00:0 WR No Violations 1.00
561435102 2015-4-6 0:00:0 SW No Violations
572190922 2010-12-9 0:00: SW No Violations
602395613 2003-9-4 0:00:0 SW No Violations 2.00
675004728 2008-5-7 0:00:0 SW No Violations
757321958 2015-5-21 0:00: SW No Violations
766214683 2016-5-18 0:00: SW No Violations
785092645 2015-1-30 0:00: SW No Violations
788205253 2015-3-31 0:00: SW No Violations
805768247 2020-10-9 0:00: SW No Violations 1.00
923202239 2009-1-5 0:00:0 SW No Violations
963406981 2004-11-9 0:00: SW No Violations 1.00
970119835 2015-1-10 0:00: SW No Violations 4.00
996504738 2018-5-17 0:00: SW No Violations
UIC1727 1998-6-25 0:00: SW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0435286527 US-OH-124673 2010-02-02 Mechanical failure/contamination
1057420391 US-OH-101074 2003-07-05 Pollution/Contamination
1057420391 US-OH-101075 2003-07-05 Violation of injection tubing/fitting requirements
1316122404 US-OH-109006 2015-08-28 Permit not displayed
1316122404 US-OH-109007 2015-08-28 Well shall be plugged
1549914798 US-OH-115050 2019-04-08 Failure to report disposal fees

For data sources see[9]

References