X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-173-20568"

m
m
 
(4 intermediate revisions by the same user not shown)
Line 1: Line 1:
__TOC__
+
__TOC__
 
== Well Details ==
 
== Well Details ==
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-173-20568
 
| Well ID: 34-173-20568
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.28336739, -83.47892184 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.28, -83.47 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Wood County, Ohio|Wood]]
+
| Country: United States
 
|-
 
|-
| Municipality:  
+
| State: Ohio
 +
|-
 +
| County: [[Wood_County,_Ohio|Wood]]
 +
|-
 +
| Municipality: [[Montgomery_Township,_Wood_County,_Ohio|Montgomery Township]]
 
|-
 
|-
 
| Operator Name: [[LANDOWNER GRANT PROGRAM 2005]]
 
| Operator Name: [[LANDOWNER GRANT PROGRAM 2005]]
Line 13: Line 17:
 
| Well Pad ID:  
 
| Well Pad ID:  
 
|-
 
|-
| Farm/Lease Name:  
+
| Farm/Lease Name: COLEMAN RICK
 
|-
 
|-
| First Permit Date:  
+
| License Status: Final Restoration
 
|-
 
|-
| Last Permit Date:  
+
| License Date: 2005-01-04
 
|-
 
|-
 
| Spud Date:  
 
| Spud Date:  
 
|-
 
|-
| Unconventional: No
+
| Spud Drilling Contractor:
 +
|-
 +
| Final Drill Date:
 +
|-
 +
| Well Total Depth:  
 
|-
 
|-
 
| Configuration: Vertical
 
| Configuration: Vertical
 
|-
 
|-
| Well Status: Final Restoration
+
| Latitude: 41.280000
 +
|-
 +
| Longitude: -83.470000
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2020-11-16
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-11-16 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Well Status
 +
!scope="col" style="width: 15%;text-align: center"| Well Status Date
 +
!scope="col" style="text-align: center"| Comment
 +
|-
 +
| APP
 +
| 2005-01-04
 +
| Proposed Formations:TRENTON, Issued Date:1/4/2005, Expired Date:1/4/2006 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
 +
|-
 +
| Plugged by Orphan Well Program
 +
| 2005-02-02
 +
| Plugged by Orphan Well Program
 
|-
 
|-
| Violations: 0
+
| Plugged/Abandoned
 +
| 2005-02-02
 +
| RBDMS Rec
 +
I&O CN 2004 08 026
 
|-
 
|-
| Latitude: 41.28336739
+
| Construction Permit Expires
 +
| 2006-01-04
 +
| RBDMS Rec
 +
I&O CN 2004 08 026
 
|-
 
|-
| Longitude: -83.47892184
+
| Record Last Modified
 +
| 2013-03-14
 +
| RBDMS Rec
 +
I&O CN 2004 08 026
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well and WellHistry Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date = 2020-11-16
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-11-16 }}</ref>
 +
<!--== Perforation Treatments ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Perforation Date
 +
!scope="col" style="text-align: center"| Interval Top (ft)
 +
!scope="col" style="text-align: center"| Interval Base (ft)
 +
!scope="col" style="text-align: center"| Number of Shots
 +
|-
 +
|}-->
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Job Start Date
 +
!scope="col" style="text-align: center"| Job End Date
 +
!scope="col" style="text-align: center"| True Vertical Depth (ft)
 +
!scope="col" style="text-align: center"| Total Water Volume (gal)
 +
!scope="col" style="text-align: center"| Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" style="width: 100%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Trade Name
 +
!scope="col" style="text-align: center"| Supplier
 +
!scope="col" style="text-align: center"| Purpose
 +
!scope="col" style="text-align: center"| Ingredient Name
 +
!scope="col" style="white-space: nowrap;text-align: center"| CAS Number
 +
!scope="col" style="text-align: center"| Additive Percentage by Mass
 +
!scope="col" style="text-align: center"| Job Percentage by Mass
 +
!scope="col" style="text-align: center"| Mass Used (lb)
 +
|-
 +
|}-->
 +
<!--== Stimulations Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Stimulation Date
 +
!scope="col" style="text-align: center"| Chemical Agent
 +
!scope="col" style="text-align: center"| Chemical Agent Concentration (%)
 +
!scope="col" style="text-align: center"| Fracking Fluid Volume
 +
!scope="col" style="text-align: center"| Mass of Proppant Used (lb)
 +
!scope="col" style="text-align: center"| Fracking Company
 +
!scope="col" style="text-align: center"| Comments
 +
|-
 +
|}-->
 +
<!--== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Gas Quantity (mcf)
 +
!scope="col" style="text-align: center"| Oil Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
|}-->
 +
<!--== Waste Data ==
 +
{| class="wikitable sortable"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Waste Type
 +
!scope="col" style="text-align: center"| Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
|}-->
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" style="text-align: center"| Inspection ID
!scope="col" | DATE
+
!scope="col" style="text-align: center"| Inspection Date
!scope="col" | DESCRIPTION
+
!scope="col" style="text-align: center"| Inspection Type
!scope="col" | COMMENT
+
!scope="col" style="text-align: center"| Inspection Result
!scope="col" | VIOLATION ID
+
!scope="col" style="text-align: center"| Inspection Comments
!scope="col" | VIOLATION CODE
 
!scope="col" | VIOLATION COMMENT
 
 
|-
 
|-
| 1107278643
+
| -633288022
| 2005-02-01
+
| 2005-4-18 0:00:
|
+
| FR
| Operator attempted to plug well but had equipment problems. Bob Harpster thought that there was too much resistance at a depth of approximately 600 feet where old tubing was not able to be removed. Pump blew off hoses and finally blew hose while trying to plug well. Cement truck had to leave site. Bob thought that plugging at depth of approximately 400 may allow cement to circulate. This is below the fresh water zone. He indicated that the depth was previously approved by Dave Hodges. Inspector will verify.
+
| No Violations
|  
 
|  
 
 
|  
 
|  
 
|-
 
|-
|-
+
| 0633288022
| -633288022
 
 
| 2005-04-18
 
| 2005-04-18
|  
+
| Final Restoration
 +
| No Violations
 
| Spoke to operator Bob Harpster by phone. He said 3 wells plugged for I&O on Coleman property have been cut off and ID plate attached. Operator did not notify inspector as requested so that ID plate placement could be observed. There is no sign of well casing at surface. Small amounts of broken cement were noted on the ground surface. The field has been recently planted. Final restoration will be recommended for approval.
 
| Spoke to operator Bob Harpster by phone. He said 3 wells plugged for I&O on Coleman property have been cut off and ID plate attached. Operator did not notify inspector as requested so that ID plate placement could be observed. There is no sign of well casing at surface. Small amounts of broken cement were noted on the ground surface. The field has been recently planted. Final restoration will be recommended for approval.
|  
+
|-
|  
+
| 1107278643
|  
+
| 2005-02-01
 +
| Orphan
 +
| No Violations
 +
| Operator attempted to plug well but had equipment problems. Bob Harpster thought that there was too much resistance at a depth of approximately 600 feet where old tubing was not able to be removed. Pump blew off hoses and finally blew hose while trying to plug well. Cement truck had to leave site. Bob thought that plugging at depth of approximately 400 may allow cement to circulate. This is below the fresh water zone. He indicated that the depth was previously approved by Dave Hodges. Inspector will verify.
 
|-
 
|-
 
|}
 
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Violation ID
 +
!scope="col" style="text-align: center"| Violation Date
 +
!scope="col" style="text-align: center"| Violation Code
 +
!scope="col" style="text-align: center"| Violation Comments
 +
|-
 +
|}-->
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Ohio Department of Natural Resources RBDMS
+
  | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
  | publisher = [http://oilandgas.ohiodnr.gov/]
+
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2015-06-19
+
  | date = 2020-11-16
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection
+
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2015-06-20 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
== References ==
+
==References==
{{reflist}}
+
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Ohio Wells]]

Latest revision as of 10:33, 12 January 2021

Well Details

Well ID: 34-173-20568
Loading map...
Country: United States
State: Ohio
County: Wood
Municipality: Montgomery Township
Operator Name: LANDOWNER GRANT PROGRAM 2005
Well Pad ID:
Farm/Lease Name: COLEMAN RICK
License Status: Final Restoration
License Date: 2005-01-04
Spud Date:
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 41.280000
Longitude: -83.470000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-01-04 Proposed Formations:TRENTON, Issued Date:1/4/2005, Expired Date:1/4/2006 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Plugged by Orphan Well Program 2005-02-02 Plugged by Orphan Well Program
Plugged/Abandoned 2005-02-02 RBDMS Rec

I&O CN 2004 08 026

Construction Permit Expires 2006-01-04 RBDMS Rec

I&O CN 2004 08 026

Record Last Modified 2013-03-14 RBDMS Rec

I&O CN 2004 08 026

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-633288022 2005-4-18 0:00: FR No Violations
0633288022 2005-04-18 Final Restoration No Violations Spoke to operator Bob Harpster by phone. He said 3 wells plugged for I&O on Coleman property have been cut off and ID plate attached. Operator did not notify inspector as requested so that ID plate placement could be observed. There is no sign of well casing at surface. Small amounts of broken cement were noted on the ground surface. The field has been recently planted. Final restoration will be recommended for approval.
1107278643 2005-02-01 Orphan No Violations Operator attempted to plug well but had equipment problems. Bob Harpster thought that there was too much resistance at a depth of approximately 600 feet where old tubing was not able to be removed. Pump blew off hoses and finally blew hose while trying to plug well. Cement truck had to leave site. Bob thought that plugging at depth of approximately 400 may allow cement to circulate. This is below the fresh water zone. He indicated that the depth was previously approved by Dave Hodges. Inspector will verify.

For data sources see[3]

References