Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-013-21139
 
| Well ID: 34-013-21139
| style="height=100%; align=center" rowspan="17" | {{#display_map: 40.144242398, -80.85509877 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 40.14, -80.85 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 11: Line 11:
 
| County: [[Belmont_County,_Ohio|Belmont]]
 
| County: [[Belmont_County,_Ohio|Belmont]]
 
|-
 
|-
| Municipality: [[Colerain Township,_Belmont_County,_Ohio|Colerain Township]]
+
| Municipality: [[Colerain_Township,_Belmont_County,_Ohio|Colerain Township]]
 
|-
 
|-
 
| Operator Name: [[ASCENT RESOURCES UTICA LLC]]
 
| Operator Name: [[ASCENT RESOURCES UTICA LLC]]
Line 19: Line 19:
 
| Farm/Lease Name: BAKOS CLR BL
 
| Farm/Lease Name: BAKOS CLR BL
 
|-
 
|-
| License Status: Well Drilled
+
| License Status: Plugged Back
 
|-
 
|-
 
| License Date: 2016-12-02
 
| License Date: 2016-12-02
Line 33: Line 33:
 
| Configuration: Vertical
 
| Configuration: Vertical
 
|-
 
|-
| Latitude: 40.144242398
+
| Latitude: 40.140000
 
|-
 
|-
| Longitude: -80.85509877
+
| Longitude: -80.850000
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
 
  | title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 
  | title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date =  2019-05-07
+
  | date =  2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
== Well History ==
 
== Well History ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 69: Line 69:
 
  | title = Risk Based Data Management System - Well and WellHistry Tables
 
  | title = Risk Based Data Management System - Well and WellHistry Tables
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2019-05-07
+
  | date = 2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
== Perforation Treatments ==
 
== Perforation Treatments ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 88: Line 88:
 
| style="text-align: right;" | 20843
 
| style="text-align: right;" | 20843
 
| style="text-align: right;" | 18
 
| style="text-align: right;" | 18
 +
|-
 +
|
 +
| style="text-align: right;" | 20732
 +
| style="text-align: right;" | 20843
 +
| style="text-align: right;" | 18
 +
|-
 +
|
 +
| style="text-align: right;" | 9825
 +
| style="text-align: right;" | 9966
 +
| style="text-align: right;" | 40
 +
|-
 +
|
 +
| style="text-align: right;" | 9825
 +
| style="text-align: right;" | 9966
 +
| style="text-align: right;" | 40
 
|-
 
|-
 
|}
 
|}
Line 93: Line 108:
 
  | title = Risk Based Data Management System - Perfs Table
 
  | title = Risk Based Data Management System - Perfs Table
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date =  2019-05-07
+
  | date =  2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
== Fracking Activities ==
 
== Fracking Activities ==
 
==== Fracking Jobs ====
 
==== Fracking Jobs ====
Line 167: Line 182:
 
| style="text-align: right;" | 5161
 
| style="text-align: right;" | 5161
 
|-
 
|-
| Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl chlorides
+
| Quaternary ammonium compounds,
 +
benzyl-C12-16-alkyldimethyl chlorides
 
| 68424-85-1
 
| 68424-85-1
 
| style="text-align: right;" | 5
 
| style="text-align: right;" | 5
Line 269: Line 285:
 
| style="text-align: right;" | 427
 
| style="text-align: right;" | 427
 
|-
 
|-
| Reaction product of acetophenone, formaldehyde, thiourea and oleic acid in dimethyl formamide
+
| Reaction product of acetophenone,
 +
formaldehyde, thiourea and
 +
oleic acid in dimethyl formamide
 
| 68527-49-1
 
| 68527-49-1
 
| style="text-align: right;" | 30
 
| style="text-align: right;" | 30
Line 401: Line 419:
 
  | title = Risk Based Data Management System - Production Table - Brine Data
 
  | title = Risk Based Data Management System - Production Table - Brine Data
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date =  2019-05-07
+
  | date =  2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
<ref>{{cite web
 
<ref>{{cite web
 
  | title = Combined Production - Brine Data
 
  | title = Combined Production - Brine Data
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2019-05-07
+
  | date = 2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 
==== Inspections Performed ====
 
==== Inspections Performed ====
Line 418: Line 436:
 
!scope="col" style="text-align: center"| Inspection Result
 
!scope="col" style="text-align: center"| Inspection Result
 
!scope="col" style="text-align: center"| Inspection Comments
 
!scope="col" style="text-align: center"| Inspection Comments
 +
|-
 +
| -1028015335
 +
| 2017-6-14 0:00:
 +
| PL
 +
| No Violations
 +
| 0.50
 +
|-
 +
| -1053995004
 +
| 2019-8-23 0:00:
 +
| PW
 +
| No Violations
 +
| 0.30
 +
|-
 +
| -1417495193
 +
| 2020-1-23 0:00:
 +
| PW
 +
| No Violations
 +
| 1.00
 +
|-
 +
| -1599955396
 +
| 2019-12-19 0:00
 +
| PW
 +
| No Violations
 +
| 1.00
 +
|-
 +
| -1817462276
 +
| 2019-11-27 0:00
 +
| PW
 +
| No Violations
 +
| 2.00
 +
|-
 +
| -1906695931
 +
| 2020-3-27 0:00:
 +
| PL
 +
| No Violations
 +
| 0.20
 +
|-
 +
| -237537465
 +
| 2017-12-8 0:00:
 +
| PW
 +
| No Violations
 +
| 1.00
 +
|-
 +
| -428762010
 +
| 2017-10-11 0:00
 +
| PW
 +
| No Violations
 +
| 1.00
 +
|-
 +
| -993993477
 +
| 2019-11-5 0:00:
 +
| DD
 +
| No Violations
 +
| 0.40
 
|-
 
|-
 
| 0237537465
 
| 0237537465
Line 442: Line 514:
 
| No Violations
 
| No Violations
 
| On the day of my inspection the site passed preliminary restoration per ORC 1509.072A.
 
| On the day of my inspection the site passed preliminary restoration per ORC 1509.072A.
 +
|-
 +
| 141931754
 +
| 2020-2-4 0:00:0
 +
| CT
 +
| No Violations
 +
| 1.00
 
|-
 
|-
 
| 1486591058
 
| 1486591058
Line 448: Line 526:
 
| No Violations
 
| No Violations
 
|  On site inspection to witness the surface casing cement job with Falcon Drilling rig # 26 and Allied Cement Service. The rig has drilled a 17.5 diameter surface borehole to a measured depth of 1,635 and ran 1,610 of 61 lb/ft J-55 buttress thread 13.375 diameter casing with a float shoe and collar casing equipment ran and proper casing centralizer placement demonstrated along with a cement basket ran on the casing at 242. Allied Cement Service cemented the casing by first establishing circulation to surface with fresh water followed by pumping 50 barrels of 6% gel then 356 barrels of Class H cement, the cement mix consisted of 1665 sacks of class H cement along with 2% calcium chloride and 1/4 lb/sk loss circulation material with the cement weight being verified by weight of scale. The cement was displaced with 232 barrels of water and the casing pressure tested to 1000 psi upon the landing of the cement plug into the float collar and cement returns were witnessed to surface.
 
|  On site inspection to witness the surface casing cement job with Falcon Drilling rig # 26 and Allied Cement Service. The rig has drilled a 17.5 diameter surface borehole to a measured depth of 1,635 and ran 1,610 of 61 lb/ft J-55 buttress thread 13.375 diameter casing with a float shoe and collar casing equipment ran and proper casing centralizer placement demonstrated along with a cement basket ran on the casing at 242. Allied Cement Service cemented the casing by first establishing circulation to surface with fresh water followed by pumping 50 barrels of 6% gel then 356 barrels of Class H cement, the cement mix consisted of 1665 sacks of class H cement along with 2% calcium chloride and 1/4 lb/sk loss circulation material with the cement weight being verified by weight of scale. The cement was displaced with 232 barrels of water and the casing pressure tested to 1000 psi upon the landing of the cement plug into the float collar and cement returns were witnessed to surface.
 +
|-
 +
| 1572976654
 +
| 2019-11-5 0:00:
 +
| PL
 +
| No Violations
 +
| 0.50
 
|-
 
|-
 
| 1919981876
 
| 1919981876
Line 460: Line 544:
 
| No Violations
 
| No Violations
 
| Falcon 26 had reached total depth of the 17.5 open hole section of the well bore. The 13.375 casing was ran and cemented to surface. The rest of the job covered by Bill Stolarik.
 
| Falcon 26 had reached total depth of the 17.5 open hole section of the well bore. The 13.375 casing was ran and cemented to surface. The rest of the job covered by Bill Stolarik.
 +
|-
 +
| 712765824
 +
| 2020-1-27 0:00:
 +
| PW
 +
| No Violations
 +
| 1.00
 +
|-
 +
| 852178462
 +
| 2017-12-8 0:00:
 +
| PW
 +
| No Violations
 +
| 1.00
 
|-
 
|-
 
|}
 
|}
Line 474: Line 570:
 
  | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
 
  | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date =  2019-05-07
+
  | date =  2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
==References==
 
==References==
 
<references/>
 
<references/>

Latest revision as of 19:15, 12 January 2021

Well Details

Well ID: 34-013-21139
Loading map...
Country: United States
State: Ohio
County: Belmont
Municipality: Colerain Township
Operator Name: ASCENT RESOURCES UTICA LLC
Well Pad ID: US-OH-001445
Farm/Lease Name: BAKOS CLR BL
License Status: Plugged Back
License Date: 2016-12-02
Spud Date: 2016-12-17
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 40.140000
Longitude: -80.850000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2016-12-02 Proposed Formations:UTICA, Issued Date:12/2/2016, Expired Date:12/2/2017 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
Correction to Well 2017-02-24 CORRECTION TO PROPOSED TOTAL DEPTH.
Record Last Modified 2017-05-08 STATUS CHANGED TO DG TO DR BASED ON COMPLETION REPORT RECEIVED FOR 34-013-2-1139-01-00-05/08/2017-ALE.
Construction Permit Expires 2017-12-02 STATUS CHANGED TO DG TO DR BASED ON COMPLETION REPORT RECEIVED FOR 34-013-2-1139-01-00-05/08/2017-ALE.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2017-10-05 9825 9966 40
2017-10-05 20732 20843 18
20732 20843 18
9825 9966 40
9825 9966 40

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 07/14/2017 08/03/2017 9809 12,554,600.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 SAND-PREMIUM WHITE-40/70, BULK Halliburton Proppant Listed Below Listed Below 0 0 0
FE-1A ACIDIZING COMPOSITION Halliburton Additive Listed Below Listed Below 0 0 0
FR-76 Halliburton Friction Reducer Listed Below Listed Below 0 0 0
Acetic acid 64-19-7 60 0.00426036 5161
Quaternary ammonium compounds,

benzyl-C12-16-alkyldimethyl chlorides

68424-85-1 5 0.0010361 1256
Ethylene Glycol 107-21-1 60 0.0179606 21758
Glutaraldehyde 111-30-8 30 0.00621663 7531
Crystalline silica, quartz 14808-60-7 100 12.0133 14,552,800.0
Inorganic salt Proprietary 30 0.0172643 20914
Olefins Proprietary 5 0.000140934 174
Neutralized Polyacrylic Emulsion Proprietary 10 0.00299343 3627
Methanol 67-56-1 60 0.000733682 890
Acetic anhydride 108-24-7 100 0.0071006 8602
Propargyl alcohol 107-19-7 10 0.000117445 143
Hydrotreated light petroleum distillate 64742-47-8 30 0.0172643 20914
Phosphoric acid 7664-38-2 0.1 0.00002072 26
Acrylamide acrylate copolymer Proprietary 30 0.0172643 20914
Ethanol 64-17-5 1 0.000207221 252
Fatty acids, tall oil Proprietary 30 0.000352335 427
Hydrochloric acid 7647-01-0 7.5 0.115516 139935
Ethoxylated alcohols Proprietary 30 0.000352335 427
Reaction product of acetophenone,

formaldehyde, thiourea and oleic acid in dimethyl formamide

68527-49-1 30 0.000352335 427
HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Listed Below Listed Below 0 0 0
Ingredients Listed Above Listed Above Water 7732-18-5 100 1.6099 1,950,220.0
MC S-2510T Halliburton Scale Inhibitor Listed Below Listed Below 0 0 0
HYDROCHLORIC ACID Halliburton Solvent Listed Below Listed Below 0 0 0
MC B-8614 Halliburton Biocide Listed Below Listed Below 0 0 0
Fresh Water Operator Base Fluid Water 7732-18-5 100 86.33 104,579,000.0
SAND-COMMON WHITE - 100 MESH, 3307 LB BAG Halliburton Proppant Listed Below Listed Below 0 0 0

For data sources see[4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2017 ASCENT RESOURCES UTICA LLC Brine 24677 103
2018 ASCENT RESOURCES UTICA LLC Brine 25362 365
2019 ASCENT RESOURCES UTICA LLC Brine 3376 86

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1028015335 2017-6-14 0:00: PL No Violations 0.50
-1053995004 2019-8-23 0:00: PW No Violations 0.30
-1417495193 2020-1-23 0:00: PW No Violations 1.00
-1599955396 2019-12-19 0:00 PW No Violations 1.00
-1817462276 2019-11-27 0:00 PW No Violations 2.00
-1906695931 2020-3-27 0:00: PL No Violations 0.20
-237537465 2017-12-8 0:00: PW No Violations 1.00
-428762010 2017-10-11 0:00 PW No Violations 1.00
-993993477 2019-11-5 0:00: DD No Violations 0.40
0237537465 2017-12-08 Production Wells No Violations This well is equipped with 5.5-inch diameter production casing. The well appears to be free flowing with no artificial lift technology present. There are gas processing units on this site. The production area currently contains two 400-barrel production fluid holding tanks. Production records for this well have not yet been submitted.
0428762010 2017-10-11 Production Wells No Violations This well is equipped with 5.5-inch diameter production casing. The well appears to be free flowing with no artificial lift technology present. The well is piped to a gas processing unit and then to a production area that contains two 400-
0852178462 2017-12-08 Production Wells No Violations This well is equipped with 5.5-inch diameter production casing. The well appears to be free flowing with no artificial lift technology present. There are gas processing units on this site. The production area currently contains two 400-barrel production fluid holding tanks. Production records for this well have not yet been submitted.
1028015335 2017-06-14 Preliminary Restoration No Violations On the day of my inspection the site passed preliminary restoration per ORC 1509.072A.
141931754 2020-2-4 0:00:0 CT No Violations 1.00
1486591058 2017-02-08 Casing String Witnessed No Violations On site inspection to witness the surface casing cement job with Falcon Drilling rig # 26 and Allied Cement Service. The rig has drilled a 17.5 diameter surface borehole to a measured depth of 1,635 and ran 1,610 of 61 lb/ft J-55 buttress thread 13.375 diameter casing with a float shoe and collar casing equipment ran and proper casing centralizer placement demonstrated along with a cement basket ran on the casing at 242. Allied Cement Service cemented the casing by first establishing circulation to surface with fresh water followed by pumping 50 barrels of 6% gel then 356 barrels of Class H cement, the cement mix consisted of 1665 sacks of class H cement along with 2% calcium chloride and 1/4 lb/sk loss circulation material with the cement weight being verified by weight of scale. The cement was displaced with 232 barrels of water and the casing pressure tested to 1000 psi upon the landing of the cement plug into the float collar and cement returns were witnessed to surface.
1572976654 2019-11-5 0:00: PL No Violations 0.50
1919981876 2018-01-09 Production Wells No Violations This well is equipped with 5.5-inch diameter production casing. The well appears to be free flowing with no artificial lift technology present. The well is piped to a gas processing unit and then to a production area. This report shall serve as a correction of the previous inspection report that stated there are two 400-barrel holding tanks. Upon further review and evaluation, the production area contains two 500-barrel production fluid storage tanks. The production reports for this well are current to 2017.
2030585138 2017-02-08 Casing String Witnessed No Violations Falcon 26 had reached total depth of the 17.5 open hole section of the well bore. The 13.375 casing was ran and cemented to surface. The rest of the job covered by Bill Stolarik.
712765824 2020-1-27 0:00: PW No Violations 1.00
852178462 2017-12-8 0:00: PW No Violations 1.00

For data sources see[7]

References