If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
(One intermediate revision by the same user not shown) | |||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 34-013-21406 | | Well ID: 34-013-21406 | ||
− | | style="height=100%; align=center" rowspan="17" | {{#display_map: 40. | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 40.0, -80.78 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 11: | Line 11: | ||
| County: [[Belmont_County,_Ohio|Belmont]] | | County: [[Belmont_County,_Ohio|Belmont]] | ||
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Pultney_Township,_Belmont_County,_Ohio|Pultney Township]] |
|- | |- | ||
| Operator Name: [[XTO ENERGY INC.]] | | Operator Name: [[XTO ENERGY INC.]] | ||
Line 19: | Line 19: | ||
| Farm/Lease Name: MILLER UNIT C | | Farm/Lease Name: MILLER UNIT C | ||
|- | |- | ||
− | | License Status: | + | | License Status: Producing |
|- | |- | ||
| License Date: 2019-03-06 | | License Date: 2019-03-06 | ||
Line 27: | Line 27: | ||
| Spud Drilling Contractor: | | Spud Drilling Contractor: | ||
|- | |- | ||
− | | Final Drill Date: | + | | Final Drill Date: 2019-06-27 |
|- | |- | ||
− | | Well Total Depth: | + | | Well Total Depth: 21581.00 ft |
|- | |- | ||
| Configuration: Horizontal | | Configuration: Horizontal | ||
|- | |- | ||
− | | Latitude: 40. | + | | Latitude: 40.000000 |
|- | |- | ||
− | | Longitude: -80. | + | | Longitude: -80.780000 |
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
| title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables | | title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables | ||
|publisher = [[Ohio Department of Natural Resources]] | |publisher = [[Ohio Department of Natural Resources]] | ||
− | | date = | + | | date = 2020-11-16 |
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
− | | accessdate = | + | | accessdate = 2020-11-16 }}</ref> |
== Well History == | == Well History == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 65: | Line 65: | ||
| title = Risk Based Data Management System - Well and WellHistry Tables | | title = Risk Based Data Management System - Well and WellHistry Tables | ||
|publisher = [[Ohio Department of Natural Resources]] | |publisher = [[Ohio Department of Natural Resources]] | ||
− | | date = | + | | date = 2020-11-16 |
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
− | | accessdate = | + | | accessdate = 2020-11-16 }}</ref> |
<!--== Perforation Treatments == | <!--== Perforation Treatments == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 137: | Line 137: | ||
!scope="col" style="text-align: center"| Inspection Result | !scope="col" style="text-align: center"| Inspection Result | ||
!scope="col" style="text-align: center"| Inspection Comments | !scope="col" style="text-align: center"| Inspection Comments | ||
+ | |- | ||
+ | | -1725755802 | ||
+ | | 2019-4-17 0:00: | ||
+ | | CS | ||
+ | | No Violations | ||
+ | | 1.50 | ||
+ | |- | ||
+ | | -2053559313 | ||
+ | | 2019-4-18 0:00: | ||
+ | | CS | ||
+ | | No Violations | ||
+ | | 2.00 | ||
+ | |- | ||
+ | | 1559570526 | ||
+ | | 2019-6-1 0:00:0 | ||
+ | | CS | ||
+ | | No Violations | ||
+ | | 4.00 | ||
|- | |- | ||
| 1725755802 | | 1725755802 | ||
Line 143: | Line 161: | ||
| No Violations | | No Violations | ||
| On the day of my inspection I witnessed Lightning Energy had drilled a 36-inch diameter hole to the depth of 100 feet. Lightning Energy ran 100.5 feet of 30-inch diameter 117 pound per foot Conductor Pipe, with .5 feet of stick up. C&J Energy Services was on location rigged up their cement lines pumped 5 barrels of fresh water and performed a 500 pound per square inch pressure test, pumped 25 barrels of gel, washed up with 5 barrels of fresh water and cemented casing with 66 barrels, 306 sacks of class A cement with 3% Calcium Chloride and .25 pound per sack of poly flake with a weight of 15.6 pounds per gallon and a yield of 1.21 cubic foot per sack. Cement weight was verified by mud scales, Cement was displaced to 90 feet with 74 barrels of fresh water, with 25 barrels of good cement to surface. Mix water was tested revealing 51 parts per million chlorides, with a PH of 7 and 72 degrees. | | On the day of my inspection I witnessed Lightning Energy had drilled a 36-inch diameter hole to the depth of 100 feet. Lightning Energy ran 100.5 feet of 30-inch diameter 117 pound per foot Conductor Pipe, with .5 feet of stick up. C&J Energy Services was on location rigged up their cement lines pumped 5 barrels of fresh water and performed a 500 pound per square inch pressure test, pumped 25 barrels of gel, washed up with 5 barrels of fresh water and cemented casing with 66 barrels, 306 sacks of class A cement with 3% Calcium Chloride and .25 pound per sack of poly flake with a weight of 15.6 pounds per gallon and a yield of 1.21 cubic foot per sack. Cement weight was verified by mud scales, Cement was displaced to 90 feet with 74 barrels of fresh water, with 25 barrels of good cement to surface. Mix water was tested revealing 51 parts per million chlorides, with a PH of 7 and 72 degrees. | ||
+ | |- | ||
+ | | 1726799114 | ||
+ | | 2020-4-10 0:00: | ||
+ | | PW | ||
+ | | No Violations | ||
+ | | 0.20 | ||
+ | |- | ||
+ | | 1867465017 | ||
+ | | 2019-8-12 0:00: | ||
+ | | CT | ||
+ | | No Violations | ||
+ | | 1.00 | ||
|- | |- | ||
| 2053559313 | | 2053559313 | ||
Line 149: | Line 179: | ||
| No Violations | | No Violations | ||
| On the day of my inspection I witnessed Lightning Energy had drilled a 36-inch diameter hole to the depth of 100 feet. Lightning Energy ran 102 feet of 30-inch diameter 117 pound per foot Conductor Pipe, with 2 feet of stick up. C&J Energy Services was on location rigged up their cement lines pumped 5 barrels of fresh water and performed a 50 pound per square inch pressure test, pumped 25 barrels of gel spacer, washed up with 5 barrels of fresh water and cemented casing with 66 barrels, 310 sacks of class A cement with 2% Calcium Chloride and .25 pound per sack of poly flake with a weight of 15.6 pounds per gallon and a yield of 1.20 cubic foot per sack. Cement weight was verified by mud scales, Cement was displaced to 84 feet with 70 barrels of fresh water, with 25 barrels of good cement to surface. | | On the day of my inspection I witnessed Lightning Energy had drilled a 36-inch diameter hole to the depth of 100 feet. Lightning Energy ran 102 feet of 30-inch diameter 117 pound per foot Conductor Pipe, with 2 feet of stick up. C&J Energy Services was on location rigged up their cement lines pumped 5 barrels of fresh water and performed a 50 pound per square inch pressure test, pumped 25 barrels of gel spacer, washed up with 5 barrels of fresh water and cemented casing with 66 barrels, 310 sacks of class A cement with 2% Calcium Chloride and .25 pound per sack of poly flake with a weight of 15.6 pounds per gallon and a yield of 1.20 cubic foot per sack. Cement weight was verified by mud scales, Cement was displaced to 84 feet with 70 barrels of fresh water, with 25 barrels of good cement to surface. | ||
+ | |- | ||
+ | | 2075626453 | ||
+ | | 2019-6-26 0:00: | ||
+ | | CS | ||
+ | | No Violations | ||
+ | | 2.00 | ||
|- | |- | ||
|} | |} | ||
Line 163: | Line 199: | ||
| title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables | | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables | ||
|publisher = [[Ohio Department of Natural Resources]] | |publisher = [[Ohio Department of Natural Resources]] | ||
− | | date = | + | | date = 2020-11-16 |
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
− | | accessdate = | + | | accessdate = 2020-11-16 }}</ref> |
==References== | ==References== | ||
<references/> | <references/> | ||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
[[Category:Ohio Wells]] | [[Category:Ohio Wells]] |
Well ID: 34-013-21406 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40,"lon":-80.78,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Belmont | |
Municipality: Pultney Township | |
Operator Name: XTO ENERGY INC. | |
Well Pad ID: US-OH-001326 | |
Farm/Lease Name: MILLER UNIT C | |
License Status: Producing | |
License Date: 2019-03-06 | |
Spud Date: 2019-04-16 | |
Spud Drilling Contractor: | |
Final Drill Date: 2019-06-27 | |
Well Total Depth: 21581.00 ft | |
Configuration: Horizontal | |
Latitude: 40.000000 | |
Longitude: -80.780000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2019-03-06 | Proposed Formations:POINT PLEASANT, Issued Date:3/6/2019, Expired Date:3/5/2021 12:00:00 PM, Drilling unit acres:643.6792, Proposed Well Type:OG, Proposed Well Class:POOL |
Record Last Modified | 2019-04-23 | |
Construction Permit Expires | 2021-03-05 |
For data sources see[2]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1725755802 | 2019-4-17 0:00: | CS | No Violations | 1.50 |
-2053559313 | 2019-4-18 0:00: | CS | No Violations | 2.00 |
1559570526 | 2019-6-1 0:00:0 | CS | No Violations | 4.00 |
1725755802 | 2019-04-17 | Casing String Witnessed | No Violations | On the day of my inspection I witnessed Lightning Energy had drilled a 36-inch diameter hole to the depth of 100 feet. Lightning Energy ran 100.5 feet of 30-inch diameter 117 pound per foot Conductor Pipe, with .5 feet of stick up. C&J Energy Services was on location rigged up their cement lines pumped 5 barrels of fresh water and performed a 500 pound per square inch pressure test, pumped 25 barrels of gel, washed up with 5 barrels of fresh water and cemented casing with 66 barrels, 306 sacks of class A cement with 3% Calcium Chloride and .25 pound per sack of poly flake with a weight of 15.6 pounds per gallon and a yield of 1.21 cubic foot per sack. Cement weight was verified by mud scales, Cement was displaced to 90 feet with 74 barrels of fresh water, with 25 barrels of good cement to surface. Mix water was tested revealing 51 parts per million chlorides, with a PH of 7 and 72 degrees. |
1726799114 | 2020-4-10 0:00: | PW | No Violations | 0.20 |
1867465017 | 2019-8-12 0:00: | CT | No Violations | 1.00 |
2053559313 | 2019-04-18 | Casing String Witnessed | No Violations | On the day of my inspection I witnessed Lightning Energy had drilled a 36-inch diameter hole to the depth of 100 feet. Lightning Energy ran 102 feet of 30-inch diameter 117 pound per foot Conductor Pipe, with 2 feet of stick up. C&J Energy Services was on location rigged up their cement lines pumped 5 barrels of fresh water and performed a 50 pound per square inch pressure test, pumped 25 barrels of gel spacer, washed up with 5 barrels of fresh water and cemented casing with 66 barrels, 310 sacks of class A cement with 2% Calcium Chloride and .25 pound per sack of poly flake with a weight of 15.6 pounds per gallon and a yield of 1.20 cubic foot per sack. Cement weight was verified by mud scales, Cement was displaced to 84 feet with 70 barrels of fresh water, with 25 barrels of good cement to surface. |
2075626453 | 2019-6-26 0:00: | CS | No Violations | 2.00 |
For data sources see[3]