X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-019-22076"

m
 
m
 
(4 intermediate revisions by the same user not shown)
Line 1: Line 1:
__TOC__
+
__TOC__
 
== Well Details ==
 
== Well Details ==
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-019-22076
 
| Well ID: 34-019-22076
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.6060365992, -81.0222697981 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 40.6, -81.02 | width=100% | height=100% }}
 
|-
 
|-
| County:
+
| Country: United States
 
|-
 
|-
| Municipality:
+
| State: Ohio
 
|-
 
|-
| Operator Name:
+
| County: [[Carroll_County,_Ohio|Carroll]]
 
|-
 
|-
| Well Pad ID:
+
| Municipality: [[Washington_Township,_Carroll_County,_Ohio|Washington Township]]
 
|-
 
|-
| Farm/Lease Name:
+
| Operator Name: [[CHESAPEAKE EXPLORATION LLC]]
 
|-
 
|-
| First Permit Date:
+
| Well Pad ID: [[US-OH-000391]]
 
|-
 
|-
| Last Permit Date:
+
| Farm/Lease Name: HARVEY 16-14-5
 +
|-
 +
| License Status: Plugged Back
 +
|-
 +
| License Date: 2011-03-28
 
|-
 
|-
 
| Spud Date: 2011-06-01
 
| Spud Date: 2011-06-01
 
|-
 
|-
| Unconventional:
+
| Spud Drilling Contractor: [[NOMAC DRILLING CORP]]
 +
|-
 +
| Final Drill Date: 2011-06-29
 +
|-
 +
| Well Total Depth: 8240.00 ft
 +
|-
 +
| Configuration: Vertical
 +
|-
 +
| Latitude: 40.600000
 +
|-
 +
| Longitude: -81.020000
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2020-11-16
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-11-16 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Well Status
 +
!scope="col" style="width: 15%;text-align: center"| Well Status Date
 +
!scope="col" style="text-align: center"| Comment
 +
|-
 +
| APP
 +
| 2011-03-28
 +
| Proposed Formations:UTICA-TRENTON-BLACK RIVER, Issued Date:3/28/2011, Expired Date:3/27/2013 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:ST, Proposed Well Class:STRT
 +
|-
 +
| Reached Total Depth
 +
| 2011-06-29
 +
|
 +
|-
 +
| Completion Report Received
 +
| 2011-08-29
 +
|
 +
|-
 +
| Construction Permit Expires
 +
| 2013-03-27
 +
|
 +
|-
 +
| Record Last Modified
 +
| 2015-07-01
 +
|
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well and WellHistry Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date = 2020-11-16
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-11-16 }}</ref>
 +
== Perforation Treatments ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Perforation Date
 +
!scope="col" style="text-align: center"| Interval Top (ft)
 +
!scope="col" style="text-align: center"| Interval Base (ft)
 +
!scope="col" style="text-align: center"| Number of Shots
 +
|-
 +
| 2011-11-21
 +
| style="text-align: right;" | 9469
 +
| style="text-align: right;" | 9841
 +
| style="text-align: right;" | 48
 +
|-
 +
| 2011-11-21
 +
| style="text-align: right;" | 10801
 +
| style="text-align: right;" | 11173
 +
| style="text-align: right;" | 48
 +
|-
 +
| 2011-11-21
 +
| style="text-align: right;" | 9913
 +
| style="text-align: right;" | 10285
 +
| style="text-align: right;" | 48
 +
|-
 +
|
 +
| style="text-align: right;" | 12133
 +
| style="text-align: right;" | 12505
 +
| style="text-align: right;" | 48
 +
|-
 +
|
 +
| style="text-align: right;" | 11689
 +
| style="text-align: right;" | 12061
 +
| style="text-align: right;" | 48
 +
|-
 +
|
 +
| style="text-align: right;" | 10801
 +
| style="text-align: right;" | 11173
 +
| style="text-align: right;" | 48
 +
|-
 +
|
 +
| style="text-align: right;" | 9469
 +
| style="text-align: right;" | 9841
 +
| style="text-align: right;" | 48
 +
|-
 +
|
 +
| style="text-align: right;" | 9025
 +
| style="text-align: right;" | 9395
 +
| style="text-align: right;" | 48
 +
|-
 +
|
 +
| style="text-align: right;" | 8581
 +
| style="text-align: right;" | 8953
 +
| style="text-align: right;" | 48
 +
|-
 +
|
 +
| style="text-align: right;" | 8137
 +
| style="text-align: right;" | 8509
 +
| style="text-align: right;" | 48
 +
|-
 +
|
 +
| style="text-align: right;" | 8137
 +
| style="text-align: right;" | 8509
 +
| style="text-align: right;" | 48
 +
|-
 +
| 2011-11-21
 +
| style="text-align: right;" | 9025
 +
| style="text-align: right;" | 9395
 +
| style="text-align: right;" | 48
 +
|-
 +
| 2011-11-21
 +
| style="text-align: right;" | 8137
 +
| style="text-align: right;" | 8509
 +
| style="text-align: right;" | 48
 
|-
 
|-
| Horizontal:
+
| 2011-11-21
 +
| style="text-align: right;" | 8581
 +
| style="text-align: right;" | 8953
 +
| style="text-align: right;" | 48
 
|-
 
|-
| Producing:
+
| 2011-11-21
 +
| style="text-align: right;" | 11689
 +
| style="text-align: right;" | 12061
 +
| style="text-align: right;" | 48
 
|-
 
|-
| Violations: 0
+
| 2011-11-21
 +
| style="text-align: right;" | 12133
 +
| style="text-align: right;" | 12505
 +
| style="text-align: right;" | 48
 
|-
 
|-
| Latitude: 40.6060365992
+
| 2011-11-21
 +
| style="text-align: right;" | 11245
 +
| style="text-align: right;" | 11617
 +
| style="text-align: right;" | 48
 
|-
 
|-
| Longitude: -81.0222697981
+
| 2011-11-21
 +
| style="text-align: right;" | 10357
 +
| style="text-align: right;" | 10722
 +
| style="text-align: right;" | 48
 
|-
 
|-
 
|}
 
|}
== Production Data ==
+
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Perfs Table
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2020-11-16
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-11-16 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" style="text-align: center"| Job Number
!scope="col" | GAS QUANTITY
+
!scope="col" style="text-align: center"| Job Start Date
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" style="text-align: center"| Job End Date
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" style="text-align: center"| True Vertical Depth (ft)
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" style="text-align: center"| Total Water Volume (gal)
!scope="col" | OIL QUANTITY
+
!scope="col" style="text-align: center"| Total Non-Water Volume (gal)
!scope="col" | OIL PRODUCTION DAYS
+
|-
 +
| 1
 +
| 08/26/2011
 +
| 08/26/2011
 +
| style="text-align: right;" | 7866.00
 +
| style="text-align: right;" | 5,145,000.0
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" style="width: 100%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Trade Name
 +
!scope="col" style="text-align: center"| Supplier
 +
!scope="col" style="text-align: center"| Purpose
 +
!scope="col" style="text-align: center"| Ingredient Name
 +
!scope="col" style="white-space: nowrap;text-align: center"| CAS Number
 +
!scope="col" style="text-align: center"| Additive Percentage by Mass
 +
!scope="col" style="text-align: center"| Job Percentage by Mass
 +
!scope="col" style="text-align: center"| Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="39"| 1
 +
| rowspan="1"| Recycled Produced Water
 +
| rowspan="1"|
 +
| rowspan="1"| Carrier/Base Fluid
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 12.07
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| WGA-15L
 +
| rowspan="2"| Weatherford
 +
| rowspan="2"| Gelling Agent
 +
| Distillates, petroleum, hydrotreated light
 +
| 64742-47-8
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.07
 +
| style="text-align: right;" |
 +
|-
 +
| Proprietary Polymer
 +
|
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.07
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| WBK-133, Breaker
 +
| rowspan="1"| Weatherford
 +
| rowspan="1"| Breaker
 +
| Peroxydisulfuric acid, diammonium salt
 +
| 7727-54-0
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.00221000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="4"| WFR-61LA
 +
| rowspan="4"| Weatherford
 +
| rowspan="4"| Friction Reducer
 +
| Distillates, petroleum, hydrotreated light
 +
| 64742-47-8
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.06
 +
| style="text-align: right;" |
 +
|-
 +
| Sodium chloride
 +
| 7647-14-5
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 +
|-
 +
| Ethoxylated C12-16 alcohols
 +
| 68551-12-2
 +
| style="text-align: right;" | 7.00
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 +
|-
 +
| Ammonium chloride
 +
| 12125-02-9
 +
| style="text-align: right;" | 7.00
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="7"| Inhibitor - WAI-251LC
 +
| rowspan="7"| Weatherford
 +
| rowspan="7"| Corrosion Inhibitor
 +
| Proprietary
 +
|
 +
| style="text-align: right;" | 13.00
 +
| style="text-align: right;" | 0.00012000
 +
| style="text-align: right;" |
 +
|-
 +
| 1-Octanol
 +
| 111-87-5
 +
| style="text-align: right;" | 7.00
 +
| style="text-align: right;" | 0.00007000
 +
| style="text-align: right;" |
 +
|-
 +
| 1-Decanol
 +
| 112-30-1
 +
| style="text-align: right;" | 7.00
 +
| style="text-align: right;" | 0.00007000
 +
| style="text-align: right;" |
 +
|-
 +
| 2-Butoxyethanol
 +
| 111-76-2
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00005000
 +
| style="text-align: right;" |
 +
|-
 +
| N,N-Dimethylformamide
 +
| 68-12-2
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00028000
 +
| style="text-align: right;" |
 +
|-
 +
| Isopropanol
 +
| 67-63-0
 +
| style="text-align: right;" | 7.00
 +
| style="text-align: right;" | 0.00007000
 +
| style="text-align: right;" |
 +
|-
 +
| Ethylene glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.00038000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="4"| WXL-105L
 +
| rowspan="4"| Weatherford
 +
| rowspan="4"| Crosslinker
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 65.00
 +
| style="text-align: right;" | 0.00687000
 +
| style="text-align: right;" |
 +
|-
 +
| Ethylene glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 35.00
 +
| style="text-align: right;" | 0.00370000
 +
| style="text-align: right;" |
 +
|-
 +
| Ethanolamine
 +
| 141-43-5
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00106000
 +
| style="text-align: right;" |
 +
|-
 +
| Boric acid
 +
| 10043-35-3
 +
| style="text-align: right;" | 15.00
 +
| style="text-align: right;" | 0.00159000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| WBK-132L
 +
| rowspan="1"| Weatherford
 +
| rowspan="1"| Breaker
 +
| No Hazardous Components
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| WCS-631LC
 +
| rowspan="2"| Weatherford
 +
| rowspan="2"| Clay Stabilizer
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 50.00
 +
| style="text-align: right;" | 0.06
 +
| style="text-align: right;" |
 +
|-
 +
| Proprietary Non Hazardous Salt
 +
|
 +
| style="text-align: right;" | 70.00
 +
| style="text-align: right;" | 0.08
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="3"| EC6110A
 +
| rowspan="3"| Nalco
 +
| rowspan="3"| Antibacterial Agent
 +
| Glutaraldehyde
 +
| 111-30-8
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 +
|-
 +
| Quaternary Ammonium Compounds
 +
|
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00306000
 +
| style="text-align: right;" |
 +
|-
 +
| Ethanol
 +
| 64-17-5
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00153000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Iron Control - WIC-641L
 +
| rowspan="1"| Weatherford
 +
| rowspan="1"| Iron Control Agent
 +
| Citric acid
 +
| 77-92-9
 +
| style="text-align: right;" | 50.00
 +
| style="text-align: right;" | 0.00220000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| EC6629 (010)
 +
| rowspan="2"| Nalco
 +
| rowspan="2"| Scale Inhibitor
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| No Hazardous Components
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| ACID, HYDROCHLORIC, 15 PCT
 +
| rowspan="2"| Weatherford
 +
| rowspan="2"| Acid
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 15.00
 +
| style="text-align: right;" | 0.06
 +
| style="text-align: right;" |
 +
|-
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 85.00
 +
| style="text-align: right;" | 0.37
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="5"| WNE-352LN
 +
| rowspan="5"| Weatherford
 +
| rowspan="5"| Non-Emulsifier
 +
| Residues, petroleum, catalytic reformer fractionator
 +
| 64741-67-9
 +
| style="text-align: right;" | 7.00
 +
| style="text-align: right;" | 0.00729000
 +
| style="text-align: right;" |
 +
|-
 +
| Isopropanol
 +
| 67-63-0
 +
| style="text-align: right;" | 13.00
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 +
|-
 +
| Naphthalene
 +
| 91-20-3
 +
| style="text-align: right;" | 1.50
 +
| style="text-align: right;" | 0.00156000
 +
| style="text-align: right;" |
 +
|-
 +
| (4R)-1-methyl-4-(prop-1-en-2-yl)cyclohexene
 +
| 5989-27-5
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 +
|-
 +
| Ethoxylated C6-12 alcohols
 +
| 68439-45-2
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.03
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| pH Adjusting Agents - WPB-584L
 +
| rowspan="2"| Weatherford
 +
| rowspan="2"| pH Adjusting Agent
 +
| Potassium hydroxide
 +
| 1310-58-3
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.00558000
 +
| style="text-align: right;" |
 +
|-
 +
| Carbonic acid, dipotassium salt
 +
| 584-08-7
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.00837000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Sand (Proppant)
 +
| rowspan="1"|
 +
| rowspan="1"| Proppant
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 11.76
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Fresh Water
 +
| rowspan="1"|
 +
| rowspan="1"| Carrier/Base Fluid
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 75.13
 +
| style="text-align: right;" |
 +
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 +
<!--== Stimulations Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Stimulation Date
 +
!scope="col" style="text-align: center"| Chemical Agent
 +
!scope="col" style="text-align: center"| Chemical Agent Concentration (%)
 +
!scope="col" style="text-align: center"| Fracking Fluid Volume
 +
!scope="col" style="text-align: center"| Mass of Proppant Used (lb)
 +
!scope="col" style="text-align: center"| Fracking Company
 +
!scope="col" style="text-align: center"| Comments
 +
|-
 +
|}-->
 +
<!--== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Gas Quantity (mcf)
 +
!scope="col" style="text-align: center"| Oil Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
|}-->
 
== Waste Data ==
 
== Waste Data ==
{| class="wikitable sortable" width="95%"
+
{| class="wikitable sortable"
!scope="col" | PERIOD
+
!scope="col" style="text-align: center"| Period
!scope="col" | TYPE
+
!scope="col" style="text-align: center"| Operator Name
!scope="col" | QUANTITY
+
!scope="col" style="text-align: center"| Waste Type
!scope="col" | UNITS
+
!scope="col" style="text-align: center"| Quantity (bbl)
!scope="col" | DISPOSAL METHOD
+
!scope="col" style="text-align: center"| Production Days
!scope="col" | WASTE FACILITY PERMIT ID
+
|-
!scope="col" | WASTE FACILITY NAME
+
| 2011
!scope="col" | FACILITY CITY
+
| [[CHESAPEAKE APPALACHIA LLC]]
!scope="col" | FACILITY STATE
+
| Brine
 +
| style="text-align: right;" | 9102
 +
| style="text-align: right;" | 92
 +
|-
 +
| 2012
 +
| [[CHESAPEAKE EXPLORATION LLC]]
 +
| Brine
 +
| style="text-align: right;" | 6587
 +
| style="text-align: right;" | 295
 +
|-
 +
| 2013
 +
| [[CHESAPEAKE EXPLORATION LLC]]
 +
| Brine
 +
| style="text-align: right;" | 1987
 +
| style="text-align: right;" | 119
 +
|-
 +
| 2014
 +
| [[CHESAPEAKE EXPLORATION LLC]]
 +
| Brine
 +
| style="text-align: right;" | 1825
 +
| style="text-align: right;" | 339
 +
|-
 +
| 2015
 +
| [[CHESAPEAKE EXPLORATION LLC]]
 +
| Brine
 +
| style="text-align: right;" | 3782
 +
| style="text-align: right;" | 292
 +
|-
 +
| 2016
 +
| [[CHESAPEAKE EXPLORATION LLC]]
 +
| Brine
 +
| style="text-align: right;" | 4373
 +
| style="text-align: right;" | 366
 +
|-
 +
| 2017
 +
| [[CHESAPEAKE EXPLORATION LLC]]
 +
| Brine
 +
| style="text-align: right;" | 2832
 +
| style="text-align: right;" | 364
 +
|-
 +
| 2018
 +
| [[CHESAPEAKE EXPLORATION LLC]]
 +
| Brine
 +
| style="text-align: right;" | 1238
 +
| style="text-align: right;" | 364
 +
|-
 +
| 2019
 +
| [[CHESAPEAKE EXPLORATION LLC]]
 +
| Brine
 +
| style="text-align: right;" | 352
 +
| style="text-align: right;" | 90
 +
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Production Table - Brine Data
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2020-11-16
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-11-16 }}</ref>
 +
<ref>{{cite web
 +
| title = Combined Production - Brine Data
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date = 2020-11-16
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-11-16 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" style="text-align: center"| Inspection ID
!scope="col" | DATE
+
!scope="col" style="text-align: center"| Inspection Date
!scope="col" | DESCRIPTION
+
!scope="col" style="text-align: center"| Inspection Type
!scope="col" | COMMENT
+
!scope="col" style="text-align: center"| Inspection Result
!scope="col" | VIOLATION ID
+
!scope="col" style="text-align: center"| Inspection Comments
!scope="col" | VIOLATION CODE
 
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
 
| -1203801268
 
| -1203801268
 +
| 2013-7-15 0:00:
 +
| PW
 +
| No Violations
 +
| 2.00
 +
|-
 +
| -1585171737
 +
| 2013-4-15 0:00:
 +
| DD
 +
| No Violations
 +
| 3.00
 +
|-
 +
| -1940948925
 +
| 2017-9-6 0:00:0
 +
| PW
 +
| No Violations
 +
| 1.00
 +
|-
 +
| -539366306
 +
| 2015-10-1 0:00:
 +
| PL
 +
| No Violations
 +
|
 +
|-
 +
| -544864317
 +
| 2019-9-3 0:00:0
 +
| PW
 +
| No Violations
 +
| 1.00
 +
|-
 +
| -551502835
 +
| 2015-10-1 0:00:
 +
| PL
 +
| No Violations
 +
|
 +
|-
 +
| 0539366306
 +
| 2015-10-01
 +
| Preliminary Restoration
 +
| No Violations
 +
| I was on location to conduct a preliminary restoration inspection.  The well is open flow with a wellhead Christmas tree assembly.  Jersey barriers were installed around the wellhead.  The well is properly identified with a clear, legibly marked well identification sign.  The tank battery consisted of six 400 BBL production tanks and was diked. The tanks are located within a spray-lined and sealed secondary containment.  There are e-stops outside the barriers, and the tanks are grounded, and have static dissipators.  There is a truck grounding area for trucks collecting condensate and/or produced water.  Lightning protection and a windsock is installed on top of the production tanks.  Other production equipment on the well pad consisted of:
 +
 +
 +
 +
 +
Jersey barriers are installed around the production equipment.  The entire well pad is enclosed with a 6 foot high, chain link fence with 3 strand barbed wire and the man doors were locked.  Along the interior of the chain link fence there is an earthen berm and it was stable. The soil stockpile is well-stabilized with vegetation.  Drainage and erosion controls at the pad are in place and functioning.  A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure.  The pad has a crushed limestone surface, and is in good repair.  The lease road is stable and drivable.  Preliminary restoration passed.
 +
|-
 +
| 0551502835
 +
| 2015-10-01
 +
| Preliminary Restoration
 +
| No Violations
 +
| I was on location to conduct a preliminary restoration inspection.  The well is open flow with a wellhead Christmas tree assembly.  Jersey barriers were installed around the wellhead.  The well is properly identified with a clear, legibly-marked well identification sign.  The tank battery consisted of six, 400 BBL production tanks and was diked. The tanks are located within a spray-lined and sealed secondary containment.  There are e-stops outside the barriers, and the tanks are grounded, and have static dissipators.  There is a truck grounding area for trucks collecting condensate and/or produced water.  Lightning protection and a windsock are installed on top of the production tanks.  Other production equipment on the well pad consisted of:
 +
 +
 +
 +
 +
Jersey barriers are installed around the production equipment.  The entire well pad is enclosed with a six-foot high, chain link fence with three-strand barbed wire and the man doors were locked.  Along the interior of the chain link fence there is an earthen berm and it was stable. The soil stockpile is well-stabilized with vegetation.  Drainage and erosion controls at the pad are in place and functioning.  A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure.  The pad has a crushed limestone surface, and is in good repair.  The lease road is stable and drivable.  Preliminary restoration passed.
 +
|-
 +
| 0689921233
 +
| 2013-06-06
 +
| Production Wells
 +
| No Violations
 +
| I was onsite to check the status of these wells. The wells have been drilled, hydraulically fractured and fully prepared for production. Currently crews are onsite preparing the flow lines for the wells to the production facilities onsite. The wells are currently shut in and the annulus and wellheads show not recordable pressures at this time. There is a gas sales line for this location so that gas will be sold when the wells are in production. There are no violations at this time for this location and these wells.
 +
|-
 +
| 1131548140
 +
| 2020-7-13 0:00:
 +
| PW
 +
| No Violations
 +
| 1.00
 +
|-
 +
| 1203801268
 
| 2013-07-15
 
| 2013-07-15
|
+
| Production Wells
 +
| No Violations
 
| I was onsite to check the erosion controls of this wellsite following strong storms that made it through the region the previous week. There were no issues on the pad and all erosion controls are working properly. The wells on this site are currently shut-in as they are waiting for the completion of the production facilities for the four wells.
 
| I was onsite to check the erosion controls of this wellsite following strong storms that made it through the region the previous week. There were no issues on the pad and all erosion controls are working properly. The wells on this site are currently shut-in as they are waiting for the completion of the production facilities for the four wells.
|
 
|
 
|
 
 
|-
 
|-
|-
+
| 1585171737
| -1585171737
 
 
| 2013-04-15
 
| 2013-04-15
|
+
| Drill / Deepen /  Reopen
 +
| No Violations
 
| I was onsite to get updated GPS coordinates for the wells on the Harvey pad. There are 4 drilled wells on the pad, 1 well was previously drilled and is producing. There is production equipment onsite including a 6 400 barrel production tank battery surrounded by a steel dike. The wells appear to be static and the site is being prepared to be hydraulically fractured in the near future. A Grady Rentals crew was onsite laying down containment for the well pad. Surrounding the well pad is new erosion controls which have been recently installed. There are no site violations at this time.
 
| I was onsite to get updated GPS coordinates for the wells on the Harvey pad. There are 4 drilled wells on the pad, 1 well was previously drilled and is producing. There is production equipment onsite including a 6 400 barrel production tank battery surrounded by a steel dike. The wells appear to be static and the site is being prepared to be hydraulically fractured in the near future. A Grady Rentals crew was onsite laying down containment for the well pad. Surrounding the well pad is new erosion controls which have been recently installed. There are no site violations at this time.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1725637136
 
| 1725637136
 
| 2013-06-06
 
| 2013-06-06
|
+
| Production Wells
 +
| No Violations
 
| I was onsite to check the status of these wells. The wells have been drilled, hydraulically fractured and fully prepared for production. Currently crews are onsite preparing the flow lines for the wells to the production facilities onsite. The wells are currently shut in and the annulus and wellheads show not recordable pressures at this time. There is a gas sales line for this location so that gas will be sold when the wells are in production. There are no violations at this time for this location and these wells.
 
| I was onsite to check the status of these wells. The wells have been drilled, hydraulically fractured and fully prepared for production. Currently crews are onsite preparing the flow lines for the wells to the production facilities onsite. The wells are currently shut in and the annulus and wellheads show not recordable pressures at this time. There is a gas sales line for this location so that gas will be sold when the wells are in production. There are no violations at this time for this location and these wells.
|
 
|
 
|
 
 
|-
 
|-
 +
| 1846632623
 +
| 2017-07-12
 +
| Production Wells
 +
| No Violations
 +
| I conducted a status check of this well.  Identification signs were posted at the access entrance and the tanks.  An identification sign for the well had fallen and was located on the ground adjacent to the well.  I requested to Jody Jones of CHK on 07/12/2017 to have the identification sign re-posted at the well.    The #8H well is in production and is equipped with a plunger-lift assembly.  The production tanks are surrounded by a steel dike.  The pad is surrounded by a fence and all man doors were locked. 
 +
The equipment on the pad consists of the following:
 +
4 producing wells
 +
 +
1 Low pressure vertical separator 
 +
4 sand separators
 +
4 gas processing units
 +
1 vapor recovery unit
 +
1 heat treater
 
|-
 
|-
 
| 1931134014
 
| 1931134014
 
| 2013-04-15
 
| 2013-04-15
|
+
| Drill / Deepen /  Reopen
 +
| No Violations
 
| I was onsite to get updated GPS coordinates for the wells on the Harvey pad. There are 4 drilled wells on the pad, 1 well was previously drilled and is producing. There is production equipment onsite including a 6 400 barrel production tank battery surrounded by a steel dike. The wells appear to be static and the site is being prepared to be hydraulically fractured in the near future. A Grady Rentals crew was onsite laying down containment for the well pad. Surrounding the well pad is new erosion controls which have been recently installed. There are no site violations at this time.
 
| I was onsite to get updated GPS coordinates for the wells on the Harvey pad. There are 4 drilled wells on the pad, 1 well was previously drilled and is producing. There is production equipment onsite including a 6 400 barrel production tank battery surrounded by a steel dike. The wells appear to be static and the site is being prepared to be hydraulically fractured in the near future. A Grady Rentals crew was onsite laying down containment for the well pad. Surrounding the well pad is new erosion controls which have been recently installed. There are no site violations at this time.
|
 
|
 
|
 
 
|-
 
|-
 +
| 1940948925
 +
| 2017-09-06
 +
| Production Wells
 +
| No Violations
 +
| I conducted a status check of the well.  I did not locate a 13.375 annular pressure gauge at the well.  I contacted Jody Jones of Chesapeake on 09/06/2017 and requested that one be installed.  No other changes have been made to the pad since my last inspection.
 
|-
 
|-
 
| 689921233
 
| 689921233
| 2013-06-06
+
| 2013-6-6 0:00:0
|
+
| PW
| I was onsite to check the status of these wells. The wells have been drilled, hydraulically fractured and fully prepared for production. Currently crews are onsite preparing the flow lines for the wells to the production facilities onsite. The wells are currently shut in and the annulus and wellheads show not recordable pressures at this time. There is a gas sales line for this location so that gas will be sold when the wells are in production. There are no violations at this time for this location and these wells.
+
| No Violations
|
+
| 1.50
|
 
|
 
 
|-
 
|-
 
|}
 
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Violation ID
 +
!scope="col" style="text-align: center"| Violation Date
 +
!scope="col" style="text-align: center"| Violation Code
 +
!scope="col" style="text-align: center"| Violation Comments
 +
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2020-11-16
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-11-16 }}</ref>
 +
==References==
 +
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Ohio Wells]]
 +
[[Category:FracFocus]]

Latest revision as of 22:47, 12 January 2021

Well Details

Well ID: 34-019-22076
Loading map...
Country: United States
State: Ohio
County: Carroll
Municipality: Washington Township
Operator Name: CHESAPEAKE EXPLORATION LLC
Well Pad ID: US-OH-000391
Farm/Lease Name: HARVEY 16-14-5
License Status: Plugged Back
License Date: 2011-03-28
Spud Date: 2011-06-01
Spud Drilling Contractor: NOMAC DRILLING CORP
Final Drill Date: 2011-06-29
Well Total Depth: 8240.00 ft
Configuration: Vertical
Latitude: 40.600000
Longitude: -81.020000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-03-28 Proposed Formations:UTICA-TRENTON-BLACK RIVER, Issued Date:3/28/2011, Expired Date:3/27/2013 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:ST, Proposed Well Class:STRT
Reached Total Depth 2011-06-29
Completion Report Received 2011-08-29
Construction Permit Expires 2013-03-27
Record Last Modified 2015-07-01

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-11-21 9469 9841 48
2011-11-21 10801 11173 48
2011-11-21 9913 10285 48
12133 12505 48
11689 12061 48
10801 11173 48
9469 9841 48
9025 9395 48
8581 8953 48
8137 8509 48
8137 8509 48
2011-11-21 9025 9395 48
2011-11-21 8137 8509 48
2011-11-21 8581 8953 48
2011-11-21 11689 12061 48
2011-11-21 12133 12505 48
2011-11-21 11245 11617 48
2011-11-21 10357 10722 48

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 08/26/2011 08/26/2011 7866.00 5,145,000.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Recycled Produced Water Carrier/Base Fluid 12.07
WGA-15L Weatherford Gelling Agent Distillates, petroleum, hydrotreated light 64742-47-8 60.00 0.07
Proprietary Polymer 60.00 0.07
WBK-133, Breaker Weatherford Breaker Peroxydisulfuric acid, diammonium salt 7727-54-0 100.00 0.00221000
WFR-61LA Weatherford Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 40.00 0.06
Sodium chloride 7647-14-5 10.00 0.01
Ethoxylated C12-16 alcohols 68551-12-2 7.00 0.01
Ammonium chloride 12125-02-9 7.00 0.01
Inhibitor - WAI-251LC Weatherford Corrosion Inhibitor Proprietary 13.00 0.00012000
1-Octanol 111-87-5 7.00 0.00007000
1-Decanol 112-30-1 7.00 0.00007000
2-Butoxyethanol 111-76-2 5.00 0.00005000
N,N-Dimethylformamide 68-12-2 30.00 0.00028000
Isopropanol 67-63-0 7.00 0.00007000
Ethylene glycol 107-21-1 40.00 0.00038000
WXL-105L Weatherford Crosslinker Water 7732-18-5 65.00 0.00687000
Ethylene glycol 107-21-1 35.00 0.00370000
Ethanolamine 141-43-5 10.00 0.00106000
Boric acid 10043-35-3 15.00 0.00159000
WBK-132L Weatherford Breaker No Hazardous Components 0.00
WCS-631LC Weatherford Clay Stabilizer Water 7732-18-5 50.00 0.06
Proprietary Non Hazardous Salt 70.00 0.08
EC6110A Nalco Antibacterial Agent Glutaraldehyde 111-30-8 60.00 0.01
Quaternary Ammonium Compounds 10.00 0.00306000
Ethanol 64-17-5 5.00 0.00153000
Iron Control - WIC-641L Weatherford Iron Control Agent Citric acid 77-92-9 50.00 0.00220000
EC6629 (010) Nalco Scale Inhibitor
No Hazardous Components 0.00
ACID, HYDROCHLORIC, 15 PCT Weatherford Acid Hydrochloric acid 7647-01-0 15.00 0.06
Water 7732-18-5 85.00 0.37
WNE-352LN Weatherford Non-Emulsifier Residues, petroleum, catalytic reformer fractionator 64741-67-9 7.00 0.00729000
Isopropanol 67-63-0 13.00 0.01
Naphthalene 91-20-3 1.50 0.00156000
(4R)-1-methyl-4-(prop-1-en-2-yl)cyclohexene 5989-27-5 10.00 0.01
Ethoxylated C6-12 alcohols 68439-45-2 30.00 0.03
pH Adjusting Agents - WPB-584L Weatherford pH Adjusting Agent Potassium hydroxide 1310-58-3 40.00 0.00558000
Carbonic acid, dipotassium salt 584-08-7 60.00 0.00837000
Sand (Proppant) Proppant 11.76
Fresh Water Carrier/Base Fluid 75.13

For data sources see[4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 CHESAPEAKE APPALACHIA LLC Brine 9102 92
2012 CHESAPEAKE EXPLORATION LLC Brine 6587 295
2013 CHESAPEAKE EXPLORATION LLC Brine 1987 119
2014 CHESAPEAKE EXPLORATION LLC Brine 1825 339
2015 CHESAPEAKE EXPLORATION LLC Brine 3782 292
2016 CHESAPEAKE EXPLORATION LLC Brine 4373 366
2017 CHESAPEAKE EXPLORATION LLC Brine 2832 364
2018 CHESAPEAKE EXPLORATION LLC Brine 1238 364
2019 CHESAPEAKE EXPLORATION LLC Brine 352 90

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1203801268 2013-7-15 0:00: PW No Violations 2.00
-1585171737 2013-4-15 0:00: DD No Violations 3.00
-1940948925 2017-9-6 0:00:0 PW No Violations 1.00
-539366306 2015-10-1 0:00: PL No Violations
-544864317 2019-9-3 0:00:0 PW No Violations 1.00
-551502835 2015-10-1 0:00: PL No Violations
0539366306 2015-10-01 Preliminary Restoration No Violations I was on location to conduct a preliminary restoration inspection. The well is open flow with a wellhead Christmas tree assembly. Jersey barriers were installed around the wellhead. The well is properly identified with a clear, legibly marked well identification sign. The tank battery consisted of six 400 BBL production tanks and was diked. The tanks are located within a spray-lined and sealed secondary containment. There are e-stops outside the barriers, and the tanks are grounded, and have static dissipators. There is a truck grounding area for trucks collecting condensate and/or produced water. Lightning protection and a windsock is installed on top of the production tanks. Other production equipment on the well pad consisted of:



Jersey barriers are installed around the production equipment. The entire well pad is enclosed with a 6 foot high, chain link fence with 3 strand barbed wire and the man doors were locked. Along the interior of the chain link fence there is an earthen berm and it was stable. The soil stockpile is well-stabilized with vegetation. Drainage and erosion controls at the pad are in place and functioning. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. The pad has a crushed limestone surface, and is in good repair. The lease road is stable and drivable. Preliminary restoration passed.

0551502835 2015-10-01 Preliminary Restoration No Violations I was on location to conduct a preliminary restoration inspection. The well is open flow with a wellhead Christmas tree assembly. Jersey barriers were installed around the wellhead. The well is properly identified with a clear, legibly-marked well identification sign. The tank battery consisted of six, 400 BBL production tanks and was diked. The tanks are located within a spray-lined and sealed secondary containment. There are e-stops outside the barriers, and the tanks are grounded, and have static dissipators. There is a truck grounding area for trucks collecting condensate and/or produced water. Lightning protection and a windsock are installed on top of the production tanks. Other production equipment on the well pad consisted of:



Jersey barriers are installed around the production equipment. The entire well pad is enclosed with a six-foot high, chain link fence with three-strand barbed wire and the man doors were locked. Along the interior of the chain link fence there is an earthen berm and it was stable. The soil stockpile is well-stabilized with vegetation. Drainage and erosion controls at the pad are in place and functioning. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. The pad has a crushed limestone surface, and is in good repair. The lease road is stable and drivable. Preliminary restoration passed.

0689921233 2013-06-06 Production Wells No Violations I was onsite to check the status of these wells. The wells have been drilled, hydraulically fractured and fully prepared for production. Currently crews are onsite preparing the flow lines for the wells to the production facilities onsite. The wells are currently shut in and the annulus and wellheads show not recordable pressures at this time. There is a gas sales line for this location so that gas will be sold when the wells are in production. There are no violations at this time for this location and these wells.
1131548140 2020-7-13 0:00: PW No Violations 1.00
1203801268 2013-07-15 Production Wells No Violations I was onsite to check the erosion controls of this wellsite following strong storms that made it through the region the previous week. There were no issues on the pad and all erosion controls are working properly. The wells on this site are currently shut-in as they are waiting for the completion of the production facilities for the four wells.
1585171737 2013-04-15 Drill / Deepen / Reopen No Violations I was onsite to get updated GPS coordinates for the wells on the Harvey pad. There are 4 drilled wells on the pad, 1 well was previously drilled and is producing. There is production equipment onsite including a 6 400 barrel production tank battery surrounded by a steel dike. The wells appear to be static and the site is being prepared to be hydraulically fractured in the near future. A Grady Rentals crew was onsite laying down containment for the well pad. Surrounding the well pad is new erosion controls which have been recently installed. There are no site violations at this time.
1725637136 2013-06-06 Production Wells No Violations I was onsite to check the status of these wells. The wells have been drilled, hydraulically fractured and fully prepared for production. Currently crews are onsite preparing the flow lines for the wells to the production facilities onsite. The wells are currently shut in and the annulus and wellheads show not recordable pressures at this time. There is a gas sales line for this location so that gas will be sold when the wells are in production. There are no violations at this time for this location and these wells.
1846632623 2017-07-12 Production Wells No Violations I conducted a status check of this well. Identification signs were posted at the access entrance and the tanks. An identification sign for the well had fallen and was located on the ground adjacent to the well. I requested to Jody Jones of CHK on 07/12/2017 to have the identification sign re-posted at the well. The #8H well is in production and is equipped with a plunger-lift assembly. The production tanks are surrounded by a steel dike. The pad is surrounded by a fence and all man doors were locked.

The equipment on the pad consists of the following: 4 producing wells

1 Low pressure vertical separator 4 sand separators 4 gas processing units 1 vapor recovery unit 1 heat treater

1931134014 2013-04-15 Drill / Deepen / Reopen No Violations I was onsite to get updated GPS coordinates for the wells on the Harvey pad. There are 4 drilled wells on the pad, 1 well was previously drilled and is producing. There is production equipment onsite including a 6 400 barrel production tank battery surrounded by a steel dike. The wells appear to be static and the site is being prepared to be hydraulically fractured in the near future. A Grady Rentals crew was onsite laying down containment for the well pad. Surrounding the well pad is new erosion controls which have been recently installed. There are no site violations at this time.
1940948925 2017-09-06 Production Wells No Violations I conducted a status check of the well. I did not locate a 13.375 annular pressure gauge at the well. I contacted Jody Jones of Chesapeake on 09/06/2017 and requested that one be installed. No other changes have been made to the pad since my last inspection.
689921233 2013-6-6 0:00:0 PW No Violations 1.50

For data sources see[7]

References