If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
(3 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | __TOC__ | + | __TOC__ |
== Well Details == | == Well Details == | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 34-019-22308 | | Well ID: 34-019-22308 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 40.45, -81.11 | width=100% | height=100% }} |
|- | |- | ||
− | | | + | | Country: United States |
|- | |- | ||
− | | | + | | State: Ohio |
|- | |- | ||
− | | | + | | County: [[Carroll_County,_Ohio|Carroll]] |
|- | |- | ||
− | | | + | | Municipality: [[Perry_Township,_Carroll_County,_Ohio|Perry Township]] |
|- | |- | ||
− | | | + | | Operator Name: [[EAP OHIO LLC]] |
|- | |- | ||
− | | | + | | Well Pad ID: [[US-OH-000637]] |
|- | |- | ||
− | | | + | | Farm/Lease Name: RAY HAYLEY 5-13-6 |
+ | |- | ||
+ | | License Status: Producing | ||
+ | |- | ||
+ | | License Date: 2014-01-16 | ||
|- | |- | ||
| Spud Date: 2014-02-01 | | Spud Date: 2014-02-01 | ||
|- | |- | ||
− | | | + | | Spud Drilling Contractor: [[NOMAC DRILLING CORP]] |
− | |||
− | |||
|- | |- | ||
− | | | + | | Final Drill Date: 2014-03-10 |
|- | |- | ||
− | | | + | | Well Total Depth: |
|- | |- | ||
− | | | + | | Configuration: Horizontal |
|- | |- | ||
− | | | + | | Latitude: 40.450000 |
|- | |- | ||
+ | | Longitude: -81.110000 | ||
|} | |} | ||
− | == | + | For data sources see<ref>{{cite web |
+ | | title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables | ||
+ | |publisher = [[Ohio Department of Natural Resources]] | ||
+ | | date = 2020-11-16 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-11-16 }}</ref> | ||
+ | == Well History == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | + | !scope="col" style="text-align: center"| Well Status |
− | + | !scope="col" style="width: 15%;text-align: center"| Well Status Date | |
− | !scope="col" | + | !scope="col" style="text-align: center"| Comment |
− | |||
− | !scope="col" | ||
− | |||
− | |||
|- | |- | ||
− | | | + | | APP |
− | | | + | | 2013-01-31 |
− | | | + | | Proposed Formations:TRENTON-BLACK RIVER, Issued Date:1/31/2013, Expired Date:1/31/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | Correction to Well |
− | + | | 2013-02-15 | |
− | + | | CORRECTION TO GROUND LEVEL ELEVATION. | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | APP |
− | | 2014- | + | | 2014-01-16 |
− | | | + | | Proposed Formations:POINT PLEASANT, Issued Date:1/16/2014, Expired Date:1/16/2016 12:00:00 PM, Drilling unit acres:273.88, Proposed Well Type:OG, Proposed Well Class:EOUT |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | Correction to Well | ||
+ | | 2014-01-24 | ||
+ | | CHANGED SURFACE FOOTAGE AND ADDED TARGET FOOTAGE. | ||
|- | |- | ||
− | | | + | | Reached Total Depth |
− | | 2014-03- | + | | 2014-03-10 |
− | |||
− | |||
− | |||
− | |||
| | | | ||
|- | |- | ||
+ | | Correction to Well | ||
+ | | 2015-01-16 | ||
+ | | CHANGES IN SURFACE, TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT. | ||
+ | |- | ||
+ | | Correction to Well | ||
+ | | 2015-01-23 | ||
+ | | UPDATE TO TAKE-POINT INFORMATION (COORDINATES) FROM NEWLY SUBMITTED PLAT. | ||
|- | |- | ||
− | | | + | | Completion Report Received |
− | | | + | | 2015-03-30 |
− | |||
− | |||
| | | | ||
+ | |- | ||
+ | | Construction Permit Expires | ||
+ | | 2016-01-16 | ||
| | | | ||
+ | |- | ||
+ | | Record Last Modified | ||
+ | | 2017-10-24 | ||
| | | | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = | + | | title = Risk Based Data Management System - Well and WellHistry Tables |
− | | publisher = [ | + | |publisher = [[Ohio Department of Natural Resources]] |
− | | date = | + | | date = 2020-11-16 |
− | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2020-11-16 }}</ref> |
− | + | <!--== Perforation Treatments == | |
− | == | + | {| class="wikitable sortable" width="95%" |
+ | !scope="col" style="text-align: center"| Perforation Date | ||
+ | !scope="col" style="text-align: center"| Interval Top (ft) | ||
+ | !scope="col" style="text-align: center"| Interval Base (ft) | ||
+ | !scope="col" style="text-align: center"| Number of Shots | ||
+ | |- | ||
+ | |}--> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" style="text-align: center"| Job Number |
− | !scope="col" | | + | !scope="col" style="text-align: center"| Job Start Date |
− | !scope="col" | | + | !scope="col" style="text-align: center"| Job End Date |
− | !scope="col" | | + | !scope="col" style="text-align: center"| True Vertical Depth (ft) |
− | !scope="col" | | + | !scope="col" style="text-align: center"| Total Water Volume (gal) |
− | !scope="col" | + | !scope="col" style="text-align: center"| Total Non-Water Volume (gal) |
− | |||
|- | |- | ||
− | | | + | | 1 |
− | | | + | | 11/12/2014 |
− | | | + | | 11/23/2014 |
− | | | + | | style="text-align: right;" | 7889 |
− | | | + | | style="text-align: right;" | 7,788,190.0 |
− | | | + | | style="text-align: right;" | 644610 |
− | | | ||
|- | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" style="width: 100%" | ||
+ | !scope="col" style="text-align: center"| Job Number | ||
+ | !scope="col" style="text-align: center"| Trade Name | ||
+ | !scope="col" style="text-align: center"| Supplier | ||
+ | !scope="col" style="text-align: center"| Purpose | ||
+ | !scope="col" style="text-align: center"| Ingredient Name | ||
+ | !scope="col" style="white-space: nowrap;text-align: center"| CAS Number | ||
+ | !scope="col" style="text-align: center"| Additive Percentage by Mass | ||
+ | !scope="col" style="text-align: center"| Job Percentage by Mass | ||
+ | !scope="col" style="text-align: center"| Mass Used (lb) | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="37"| 1 |
− | | | + | |- valign="top" |
− | | CI-150 | + | | rowspan="8"| APB01 (AMMONIUM PERSUFATE BREAKER), |
− | | Corrosion Inhibitor | + | BXL02E (BORATE XL- INSTANT |
+ | XL), CI-150, CS-250 SI, FE 200, | ||
+ | FRW-200, ICI-3240 (1 GAL), LTB-01 | ||
+ | | rowspan="8"| FTS INTERNATIONAL | ||
+ | | rowspan="8"| Anti-Bacterial Agent, Breaker, Corrosion Inhibitor, Cross Linker, Friction Reducer, Iron Control Agent, Scale Inhibitor | ||
+ | | Proprietary Friction Reducer Additive | ||
+ | (FRW-200 and FRW-200W) | ||
| TRADE SECRET | | TRADE SECRET | ||
− | | | + | | style="text-align: right;" | 0 |
+ | | style="text-align: right;" | 0.04048 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | Proprietary Breaker (APB01) Additive | ||
+ | | TRADE SECRET | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | + | | Proprietary Corrosion Inhibitor Additive (CI-150) | |
− | | Proprietary | ||
− | |||
− | |||
− | |||
| TRADE SECRET | | TRADE SECRET | ||
− | | | + | | style="text-align: right;" | 0 |
+ | | style="text-align: right;" | 0.00058 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | Water | ||
+ | | 007732-18-5 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.07651 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | Proprietary Breaker Additive (LTB-1) |
− | | | + | | TRADE SECRET |
− | | | + | | style="text-align: right;" | 0 |
− | | | + | | style="text-align: right;" | 0.0128 |
− | | | + | | style="text-align: right;" | 0 |
− | | | ||
− | | | ||
|- | |- | ||
+ | | Proprietary Iron Control Additive (FE-200L) | ||
+ | | TRADE SECRET | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00275 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | + | | Proprietary Anti-Bacterial Additive (ICI-3240) | |
− | | Proprietary | ||
− | |||
− | |||
− | |||
| TRADE SECRET | | TRADE SECRET | ||
− | | | + | | style="text-align: right;" | 0 |
+ | | style="text-align: right;" | 0.01228 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | Non-MSDS Components Not Provided by Supplier | ||
+ | | NOT PROVIDED | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="1"| BXL02E (BORATE XL- INSTANT XL) |
− | | | + | | rowspan="1"| FTS INTERNATIONAL |
− | | | + | | rowspan="1"| Cross Linker |
− | | | + | | Sodium Metaborate Tetrahydrate |
− | | | + | | 010555-76-7 |
− | | | + | | style="text-align: right;" | 30 |
− | |- | + | | style="text-align: right;" | 0.0193 |
− | |- | + | | style="text-align: right;" | 0 |
− | | | ||
− | | | ||
− | | | ||
− | |||
− | | | ||
− | | | ||
− | |||
|- | |- | ||
− | |- | + | |- valign="top" |
− | | | + | | rowspan="3"| FE 200 |
+ | | rowspan="3"| FTS INTERNATIONAL | ||
+ | | rowspan="3"| Iron Control Agent | ||
| Tetrasodium Ethylenediaminetetraacetate | | Tetrasodium Ethylenediaminetetraacetate | ||
− | |||
− | |||
− | |||
| 000064-02-8 | | 000064-02-8 | ||
− | | | + | | style="text-align: right;" | 41 |
+ | | style="text-align: right;" | 0.00154 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | Trisodium Nitrilotriacetate | ||
+ | | 005064-31-3 | ||
+ | | style="text-align: right;" | 2 | ||
+ | | style="text-align: right;" | 0.00008000 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | |||
| Sodium Hydroxide | | Sodium Hydroxide | ||
− | |||
− | |||
− | |||
| 001310-73-2 | | 001310-73-2 | ||
− | | | + | | style="text-align: right;" | 2 |
+ | | style="text-align: right;" | 0.00007000 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| 100 Mesh Sand | ||
+ | | rowspan="1"| FTS INTERNATIONAL | ||
+ | | rowspan="1"| Proppant - Natural | ||
+ | | Crystalline Silica (Quartz Sand, Silicon Dioxide) | ||
+ | | 014808-60-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.43204 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="4"| HVG01 (TURQUOISE-1 BULK) |
− | | | + | | rowspan="4"| FTS INTERNATIONAL |
− | | | + | | rowspan="4"| Gelling Agent |
− | | | + | | Petroleum Distillate Hydrotreated Light |
− | | | + | | 064742-47-8 |
− | | | + | | style="text-align: right;" | 55 |
+ | | style="text-align: right;" | 0.08438 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | Crystalline Silica (Quartz Sand, Silicon Dioxide) | ||
+ | | 014808-60-7 | ||
+ | | style="text-align: right;" | 2 | ||
+ | | style="text-align: right;" | 0.00307 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | 0 | + | | Guar Gum |
− | | | + | | 009000-30-0 |
− | | | + | | style="text-align: right;" | 50 |
− | | | + | | style="text-align: right;" | 0.07671 |
− | | | + | | style="text-align: right;" | 0 |
− | | | ||
− | | | ||
|- | |- | ||
+ | | Surfactant | ||
+ | | 068439-51-0 | ||
+ | | style="text-align: right;" | 2 | ||
+ | | style="text-align: right;" | 0.00307 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="1"| CS-250 SI |
− | | | + | | rowspan="1"| FTS INTERNATIONAL |
− | | | + | | rowspan="1"| Scale Inhibitor |
− | | | + | | Ethylene Glycol |
− | | | + | | 000107-21-1 |
− | | | + | | style="text-align: right;" | 10 |
+ | | style="text-align: right;" | 0.00129 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="3"| LTB-01 | ||
+ | | rowspan="3"| FTS INTERNATIONAL | ||
+ | | rowspan="3"| Breaker | ||
+ | | Crystalline Silica (Quartz Sand, Silicon Dioxide) | ||
+ | | 014808-60-7 | ||
+ | | style="text-align: right;" | 25 | ||
+ | | style="text-align: right;" | 0.01076 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | Proprietary Cured Acrylic Resin |
− | | | + | | TRADE SECRET |
− | | | + | | style="text-align: right;" | 25 |
− | | | + | | style="text-align: right;" | 0.01076 |
− | | | + | | style="text-align: right;" | 0 |
− | | | ||
− | | | ||
|- | |- | ||
+ | | Ammonium Persulfate | ||
+ | | 007727-54-0 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.04305 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="5"| CI-150 |
− | | | + | | rowspan="5"| FTS INTERNATIONAL |
− | | | + | | rowspan="5"| Corrosion Inhibitor |
− | | | + | | Proprietary Quaternary Ammonium Compound |
− | | | + | | TRADE SECRET |
− | | | + | | style="text-align: right;" | 10 |
+ | | style="text-align: right;" | 0.00011 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | Dimethyl Formamide | ||
+ | | 000068-12-2 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00011 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | Proprietary Aromatic Aldehyde |
− | | | + | | TRADE SECRET |
− | | | + | | style="text-align: right;" | 10 |
− | | | + | | style="text-align: right;" | 0.00011 |
− | | | + | | style="text-align: right;" | 0 |
− | | | ||
− | |||
|- | |- | ||
− | + | | Proprietary Organic Amine Resin Salt | |
− | |||
− | | Proprietary | ||
− | |||
− | |||
− | |||
| TRADE SECRET | | TRADE SECRET | ||
− | | | + | | style="text-align: right;" | 30 |
+ | | style="text-align: right;" | 0.00032 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | Isopropanol (Isopropyl Alcohol, Propan-2-ol) | ||
+ | | 000067-63-0 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.00065 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | |- valign="top" |
+ | | rowspan="1"| Fresh Water | ||
+ | | rowspan="1"| CHESAPEAKE ENERGY | ||
+ | | rowspan="1"| Carrier/Base Fluid | ||
| Water | | Water | ||
− | |||
− | |||
− | |||
| 007732-18-5 | | 007732-18-5 | ||
− | | | + | | style="text-align: right;" | 100 |
+ | | style="text-align: right;" | 82.7123 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| 10.1 - 15 HCL | ||
+ | | rowspan="2"| FTS INTERNATIONAL | ||
+ | | rowspan="2"| Acid | ||
+ | | Water | ||
+ | | 007732-18-5 | ||
+ | | style="text-align: right;" | 85 | ||
+ | | style="text-align: right;" | 0.04899 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | Hydrochloric Acid |
− | | | + | | 007647-01-0 |
− | + | | style="text-align: right;" | 15 | |
− | | | + | | style="text-align: right;" | 0.00864 |
− | | | + | | style="text-align: right;" | 0 |
− | | | ||
− | | | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| 7.5pct HCl | ||
+ | | rowspan="2"| FTS INTERNATIONAL | ||
+ | | rowspan="2"| Acid | ||
+ | | Water | ||
+ | | 007732-18-5 | ||
+ | | style="text-align: right;" | 93 | ||
+ | | style="text-align: right;" | 0.50359 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | Hydrochloric Acid |
− | | | + | | 007647-01-0 |
− | + | | style="text-align: right;" | 8 | |
− | | | + | | style="text-align: right;" | 0.04083 |
− | | | + | | style="text-align: right;" | 0 |
− | | | ||
− | | | ||
|- | |- | ||
− | |- | + | |- valign="top" |
− | | | + | | rowspan="1"| FRW-200 |
+ | | rowspan="1"| FTS INTERNATIONAL | ||
+ | | rowspan="1"| Friction Reducer | ||
| Petroleum Distillate Hydrotreated Light | | Petroleum Distillate Hydrotreated Light | ||
− | |||
− | |||
− | |||
| 064742-47-8 | | 064742-47-8 | ||
− | | FTS INTERNATIONAL | + | | style="text-align: right;" | 26 |
+ | | style="text-align: right;" | 0.01074 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| ICI-3240 (1 GAL) | ||
+ | | rowspan="2"| FTS INTERNATIONAL | ||
+ | | rowspan="2"| Anti-Bacterial Agent | ||
+ | | Sodium Hydroxide | ||
+ | | 001310-73-2 | ||
+ | | style="text-align: right;" | 4 | ||
+ | | style="text-align: right;" | 0.00054 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | Dazomet | ||
+ | | 000533-74-4 | ||
+ | | style="text-align: right;" | 24 | ||
+ | | style="text-align: right;" | 0.00326 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Northern White Sand | ||
+ | | rowspan="1"| FTS INTERNATIONAL | ||
+ | | rowspan="1"| Proppant - Natural | ||
+ | | Crystalline Silica (Quartz Sand, Silicon Dioxide) | ||
+ | | 014808-60-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 15.4743 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| APB01 (AMMONIUM PERSUFATE BREAKER) | ||
+ | | rowspan="1"| FTS INTERNATIONAL | ||
+ | | rowspan="1"| Breaker | ||
+ | | Ammonium Persulfate | ||
+ | | 007727-54-0 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00007000 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | |- valign="top" |
+ | | rowspan="1"| Recycled Produced Water | ||
+ | | rowspan="1"| CHESAPEAKE ENERGY | ||
+ | | rowspan="1"| Carrier/Base Fluid | ||
| Water | | Water | ||
− | |||
− | |||
− | |||
| 007732-18-5 | | 007732-18-5 | ||
− | | | + | | style="text-align: right;" | 100 |
+ | | style="text-align: right;" | 0.44574 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = FracFocus Fracking Chemicals Database | ||
+ | | date = 2019-04-02 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
+ | == Stimulations Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" style="text-align: center"| Stimulation Date | ||
+ | !scope="col" style="text-align: center"| Chemical Agent | ||
+ | !scope="col" style="text-align: center"| Chemical Agent Concentration (%) | ||
+ | !scope="col" style="text-align: center"| Fracking Fluid Volume | ||
+ | !scope="col" style="text-align: center"| Mass of Proppant Used (lb) | ||
+ | !scope="col" style="text-align: center"| Fracking Company | ||
+ | !scope="col" style="text-align: center"| Comments | ||
+ | |- | ||
+ | | 2014-11-23 | ||
+ | | H2O | ||
+ | | style="text-align: right;" | 15 | ||
+ | | style="text-align: right;" | 2476 Bbl | ||
+ | | style="text-align: right;" | 401600 | ||
+ | | [[Frac Tech Services]] | ||
+ | | STAGE 31/31 | ||
+ | 25 SHOTS | ||
|- | |- | ||
+ | | 2014-11-12 | ||
+ | | H2O | ||
+ | | style="text-align: right;" | 15 | ||
+ | | style="text-align: right;" | 3692 Bbl | ||
+ | | style="text-align: right;" | 406000 | ||
+ | | [[Frac Tech Services]] | ||
+ | | STAGE 1/31 | ||
+ | 25 SHOTS | ||
+ | STAGE 2-30 SEE IMAGES | ||
|- | |- | ||
− | | | + | |} |
− | | | + | For data sources see<ref>{{cite web |
− | | | + | | title = Risk Based Data Management System - tblStimulation Table |
− | | | + | |publisher = [[Ohio Department of Natural Resources]] |
− | | | + | | date = 2020-11-16 |
− | | | + | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources |
− | | | + | | accessdate = 2020-11-16 }}</ref> |
+ | == Production Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" style="text-align: center"| Period | ||
+ | !scope="col" style="text-align: center"| Operator Name | ||
+ | !scope="col" style="text-align: center"| Gas Quantity (mcf) | ||
+ | !scope="col" style="text-align: center"| Oil Quantity (bbl) | ||
+ | !scope="col" style="text-align: center"| Production Days | ||
+ | |- | ||
+ | | 2015 | ||
+ | | [[CHESAPEAKE EXPLORATION LLC]] | ||
+ | | style="text-align: right;" | 520378 | ||
+ | | style="text-align: right;" | 63581 | ||
+ | | style="text-align: right;" | 325 | ||
|- | |- | ||
+ | | 2016 | ||
+ | | [[CHESAPEAKE EXPLORATION LLC]] | ||
+ | | style="text-align: right;" | 259303 | ||
+ | | style="text-align: right;" | 22839 | ||
+ | | style="text-align: right;" | 366 | ||
|- | |- | ||
− | | | + | | 2017 |
− | | | + | | [[CHESAPEAKE EXPLORATION LLC]] |
− | | | + | | style="text-align: right;" | 182617 |
− | | | + | | style="text-align: right;" | 12811 |
− | | | + | | style="text-align: right;" | 345 |
− | | | ||
− | | | ||
|- | |- | ||
+ | | 2018 | ||
+ | | [[CHESAPEAKE EXPLORATION LLC]] | ||
+ | | style="text-align: right;" | 93042 | ||
+ | | style="text-align: right;" | 6686 | ||
+ | | style="text-align: right;" | 326 | ||
|- | |- | ||
− | | | + | | 2019 |
− | | | + | | [[CHESAPEAKE EXPLORATION LLC]] |
− | | | + | | style="text-align: right;" | 22142 |
− | | | + | | style="text-align: right;" | 1519 |
− | | | + | | style="text-align: right;" | 90 |
− | | | ||
− | | | ||
|- | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Risk Based Data Management System - Production Table - Oil and Gas Data | ||
+ | |publisher = [[Ohio Department of Natural Resources]] | ||
+ | | date = 2020-11-16 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-11-16 }}</ref> | ||
+ | <ref>{{cite web | ||
+ | | title = Combined Production - Oil and Gas Data | ||
+ | |publisher = [[Ohio Department of Natural Resources]] | ||
+ | | date = 2020-11-16 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-11-16 }}</ref> | ||
+ | == Waste Data == | ||
+ | {| class="wikitable sortable" | ||
+ | !scope="col" style="text-align: center"| Period | ||
+ | !scope="col" style="text-align: center"| Operator Name | ||
+ | !scope="col" style="text-align: center"| Waste Type | ||
+ | !scope="col" style="text-align: center"| Quantity (bbl) | ||
+ | !scope="col" style="text-align: center"| Production Days | ||
|- | |- | ||
− | | | + | | 2015 |
− | | | + | | [[CHESAPEAKE EXPLORATION LLC]] |
− | + | | Brine | |
− | | | + | | style="text-align: right;" | 26500 |
− | | | + | | style="text-align: right;" | 325 |
− | | | ||
− | | | ||
|- | |- | ||
+ | | 2016 | ||
+ | | [[CHESAPEAKE EXPLORATION LLC]] | ||
+ | | Brine | ||
+ | | style="text-align: right;" | 5790 | ||
+ | | style="text-align: right;" | 366 | ||
|- | |- | ||
− | | | + | | 2017 |
− | | | + | | [[CHESAPEAKE EXPLORATION LLC]] |
− | | | + | | Brine |
− | | | + | | style="text-align: right;" | 4450 |
− | + | | style="text-align: right;" | 345 | |
− | | | ||
− | | | ||
|- | |- | ||
+ | | 2018 | ||
+ | | [[CHESAPEAKE EXPLORATION LLC]] | ||
+ | | Brine | ||
+ | | style="text-align: right;" | 9141 | ||
+ | | style="text-align: right;" | 326 | ||
|- | |- | ||
− | | | + | | 2019 |
− | | | + | | [[CHESAPEAKE EXPLORATION LLC]] |
− | + | | Brine | |
− | | | + | | style="text-align: right;" | 1677 |
− | | | + | | style="text-align: right;" | 90 |
− | | | ||
− | | | ||
|- | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Risk Based Data Management System - Production Table - Brine Data | ||
+ | |publisher = [[Ohio Department of Natural Resources]] | ||
+ | | date = 2020-11-16 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-11-16 }}</ref> | ||
+ | <ref>{{cite web | ||
+ | | title = Combined Production - Brine Data | ||
+ | |publisher = [[Ohio Department of Natural Resources]] | ||
+ | | date = 2020-11-16 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-11-16 }}</ref> | ||
+ | == Inspection Data == | ||
+ | ==== Inspections Performed ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" style="text-align: center"| Inspection ID | ||
+ | !scope="col" style="text-align: center"| Inspection Date | ||
+ | !scope="col" style="text-align: center"| Inspection Type | ||
+ | !scope="col" style="text-align: center"| Inspection Result | ||
+ | !scope="col" style="text-align: center"| Inspection Comments | ||
|- | |- | ||
− | | | + | | -1889442261 |
− | + | | 2017-3-2 0:00:0 | |
− | | 0 | + | | PL |
− | | | + | | No Violations |
− | | | + | | |
− | | | ||
− | |||
|- | |- | ||
+ | | -2077328686 | ||
+ | | 2018-11-19 0:00 | ||
+ | | PW | ||
+ | | No Violations | ||
+ | | 1.00 | ||
|- | |- | ||
− | | | + | | 0332798325 |
− | | | + | | 2014-02-03 |
− | + | | Drill / Deepen / Reopen | |
− | + | | No Violations | |
− | | | + | | I was on site to witness the cementing of the 20 inch conductor casing. My inspection revealed that Enviro Drill has drilled a 30 inch hole to a total depth of 120 feet and ran 120 of 20 inch conductor casing (78.67 pounds per foot / inside diameter of 19.25 inches). Allied pumped 433 sacks of Class A cement with 2% CaCl and 1/2 pound per sack floseal. The cement had a density of 15.6 pounds per gallon, a yield of 1.18 cubic feet per sack, and they used 5.23 gallons of mix water per sack. Allied pumped 91 barrels of cement slurry, 39.5 barrels of displacement, and there was 10 barrels of cement returns to surface. My inspection revealed no violations at this time. NOTE: Started pumping water on the 6H well and found the 2 inch ball valve on the conductor cap was split. Enviro Drill replaced the ball valve and Allied started pumping on the casing again. Had to shut down again because the weld on the conductor cap was leaking. They also found that the 5H and 10H conductor holes were communicating so they decided to pump this cement job first and then go back to the 5H and 10H conductor cement jobs. Region Supervisor Tom Hill was present for the cementing of the casing. |
− | | | ||
− | | | ||
|- | |- | ||
+ | | 1010857237 | ||
+ | | 2019-12-9 0:00: | ||
+ | | PW | ||
+ | | No Violations | ||
+ | | 0.80 | ||
|- | |- | ||
− | | | + | | 1393923913 |
− | | | + | | 2014-03-04 |
− | | | + | | Drill / Deepen / Reopen |
− | | | + | | No Violations |
− | + | | Inspector James Bucksar and I were on site to witness the cementing of the 13 3/8 inch surface casing. Our inspection revealed that Nomac Drilling Rig # 71 has drilled a 17 1/2 inch hole to a total depth of 575 feet and ran 565 feet of 13 3/8 inch surface casing (54.5 pounds per foot / inside diameter is 12.615 inches). They installed 7 bowspring centralizers on the casing string on joints (2 on 1st, 2,3,6,9, and 12). Schlumberger cemented the casing with 514 sacks of Class A D901 with 1% D154, 0.5 B348, 0.15% B160A,, 0.2% D046, .125 pound per sack D130. The cement had a density of 15.6 pounds per gallon, a yield of 1.2 cubic feet per sack, and they used 5.219 gallons of mix water per sack. Schlumberger pumped 110 barrels of cement slurry, 80.5 barrels of displacement, and there was 21 barrels of cement returns to surface. They landed the plug with 275 PSI and bumped the pressure up to 728 PSI for the casing test. The casing test was approved, they released the pressure, the floats held, and there was 1/2 barrel of water flowed back when the pressure was released. Our inspection revealed no violations at this time. | |
− | |||
− | |||
|- | |- | ||
+ | | 1394076265 | ||
+ | | 2014-03-05 | ||
+ | | Drill / Deepen / Reopen | ||
+ | | No Violations | ||
+ | | I was on site to witness the cementing of the 9 5/8 inch intermediate casing. My inspection revealed that Nomac Drilling Rig #71 has drilled a 12 1/4 inch hole to a total depth of 1896 feet and ran 1888 feet of 9 5/8 inch intermediate casing (40 pounds per foot / inside diameter 8.830 inches). They installed 17 bowspring centralizers on the casing string; 2 on 1st joint,2,3,6,9,12,15,18,21,24,27,30,33,36,39,and 42. O-TEX cemented the casing with 690 sacks of Class H with 3% Gypsum, 2% CaCl, 0.8% MC500,0.5% C45, and 0.4% C-41P. The cement had a density of 15.8 pounds per gallon, a yield of 1.21 cubic feet per sack, and they used 5.14 gallons of mix water per sack. O-TEX pumped 149 barrels of cement slurry, 133 barrels of displacement, and there was 28 barrels of cement returns to surface. They bumped the plug with 1110 PSI and then took the pressure up to 1606 PSI and conducted the casing test. The casing test was approved, pressure was released, floats held, and there was 3/4 barrel of water flowed back. My inspection revealed no violations at this time. | ||
|- | |- | ||
− | | | + | | 1889442261 |
− | | | + | | 2017-03-02 |
− | | | + | | Preliminary Restoration |
− | | | + | | No Violations |
− | + | | I was on location to conduct a preliminary restoration inspection. The #6H well is in production and is equipped with plunger lift assembly. Jersey barriers were installed around the wellhead. The well is identified with a legibly-marked well identification sign. Identification was posted at the tank battery which consisted of eight 400 bbl production tanks, four labeled as containing produced water, and four labelled as containing condensate, and one low-pressure vertical separator. The tank battery is surrounded by a dike. There are e-stops outside the barriers, and the tanks are grounded, and have static dissipaters. There is a truck grounding area for trucks collecting condensate and/or produced water. Lightning protection and a windsock are installed on top of the production tanks. Production equipment on the well pad consisted of: | |
− | + | 6 producing wells | |
− | + | 8- 400 bbl production tanks, four labelled as containing fresh water, and four labelled as containing condensate | |
+ | 6 sand separators | ||
+ | 6 gas processing units | ||
+ | 1 low pressure vertical separator located inside of the dike | ||
+ | 1 vapor recovery unit | ||
+ | 1 horizontal separator, | ||
+ | 1 compressor station | ||
+ | 2 bullet tanks | ||
+ | Jersey barriers are installed around the production equipment. The access road and man doors were locked. Drainage and erosion controls at the pad are in place and functioning. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. The pad has a crushed limestone surface, and is in good repair. The lease road was stable in in good repair. | ||
|- | |- | ||
+ | | 2077328686 | ||
+ | | 2018-11-19 | ||
+ | | Production Wells | ||
+ | | No Violations | ||
+ | | The well was equipped with a plunger-lift assembly. The surface/intermediate and intermediate/production annular gauges displayed readings of zero psi. I performed a walk-around inspection of the pad and erosional controls appeared functioning. No violations were observed at the time of inspection. | ||
|- | |- | ||
− | | | + | | 332798325 |
− | | | + | | 2014-2-3 0:00:0 |
− | + | | DD | |
− | | | + | | No Violations |
− | | | + | | 5.00 |
− | | | ||
− | |||
|- | |- | ||
|} | |} | ||
− | For data sources see<ref>{{cite web | title = | + | <!--==== Violations Commited ==== |
− | == References == | + | {| class="wikitable sortable" width="95%" |
− | + | !scope="col" style="text-align: center"| Inspection ID | |
+ | !scope="col" style="text-align: center"| Violation ID | ||
+ | !scope="col" style="text-align: center"| Violation Date | ||
+ | !scope="col" style="text-align: center"| Violation Code | ||
+ | !scope="col" style="text-align: center"| Violation Comments | ||
+ | |- | ||
+ | |}--> | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables | ||
+ | |publisher = [[Ohio Department of Natural Resources]] | ||
+ | | date = 2020-11-16 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-11-16 }}</ref> | ||
+ | ==References== | ||
+ | <references/> | ||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
− | [[Category:Wells]] | + | [[Category:Ohio Wells]] |
+ | [[Category:FracFocus]] |
Well ID: 34-019-22308 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.45,"lon":-81.11,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Carroll | |
Municipality: Perry Township | |
Operator Name: EAP OHIO LLC | |
Well Pad ID: US-OH-000637 | |
Farm/Lease Name: RAY HAYLEY 5-13-6 | |
License Status: Producing | |
License Date: 2014-01-16 | |
Spud Date: 2014-02-01 | |
Spud Drilling Contractor: NOMAC DRILLING CORP | |
Final Drill Date: 2014-03-10 | |
Well Total Depth: | |
Configuration: Horizontal | |
Latitude: 40.450000 | |
Longitude: -81.110000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2013-01-31 | Proposed Formations:TRENTON-BLACK RIVER, Issued Date:1/31/2013, Expired Date:1/31/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
Correction to Well | 2013-02-15 | CORRECTION TO GROUND LEVEL ELEVATION. |
APP | 2014-01-16 | Proposed Formations:POINT PLEASANT, Issued Date:1/16/2014, Expired Date:1/16/2016 12:00:00 PM, Drilling unit acres:273.88, Proposed Well Type:OG, Proposed Well Class:EOUT |
Correction to Well | 2014-01-24 | CHANGED SURFACE FOOTAGE AND ADDED TARGET FOOTAGE. |
Reached Total Depth | 2014-03-10 | |
Correction to Well | 2015-01-16 | CHANGES IN SURFACE, TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT. |
Correction to Well | 2015-01-23 | UPDATE TO TAKE-POINT INFORMATION (COORDINATES) FROM NEWLY SUBMITTED PLAT. |
Completion Report Received | 2015-03-30 | |
Construction Permit Expires | 2016-01-16 | |
Record Last Modified | 2017-10-24 |
For data sources see[2]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 11/12/2014 | 11/23/2014 | 7889 | 7,788,190.0 | 644610 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | ||||||||
APB01 (AMMONIUM PERSUFATE BREAKER),
BXL02E (BORATE XL- INSTANT XL), CI-150, CS-250 SI, FE 200, FRW-200, ICI-3240 (1 GAL), LTB-01 |
FTS INTERNATIONAL | Anti-Bacterial Agent, Breaker, Corrosion Inhibitor, Cross Linker, Friction Reducer, Iron Control Agent, Scale Inhibitor | Proprietary Friction Reducer Additive
(FRW-200 and FRW-200W) |
TRADE SECRET | 0 | 0.04048 | 0 | |
Proprietary Breaker (APB01) Additive | TRADE SECRET | 0 | 0 | 0 | ||||
Proprietary Corrosion Inhibitor Additive (CI-150) | TRADE SECRET | 0 | 0.00058 | 0 | ||||
Water | 007732-18-5 | 0 | 0.07651 | 0 | ||||
Proprietary Breaker Additive (LTB-1) | TRADE SECRET | 0 | 0.0128 | 0 | ||||
Proprietary Iron Control Additive (FE-200L) | TRADE SECRET | 0 | 0.00275 | 0 | ||||
Proprietary Anti-Bacterial Additive (ICI-3240) | TRADE SECRET | 0 | 0.01228 | 0 | ||||
Non-MSDS Components Not Provided by Supplier | NOT PROVIDED | 0 | 0 | 0 | ||||
BXL02E (BORATE XL- INSTANT XL) | FTS INTERNATIONAL | Cross Linker | Sodium Metaborate Tetrahydrate | 010555-76-7 | 30 | 0.0193 | 0 | |
FE 200 | FTS INTERNATIONAL | Iron Control Agent | Tetrasodium Ethylenediaminetetraacetate | 000064-02-8 | 41 | 0.00154 | 0 | |
Trisodium Nitrilotriacetate | 005064-31-3 | 2 | 0.00008000 | 0 | ||||
Sodium Hydroxide | 001310-73-2 | 2 | 0.00007000 | 0 | ||||
100 Mesh Sand | FTS INTERNATIONAL | Proppant - Natural | Crystalline Silica (Quartz Sand, Silicon Dioxide) | 014808-60-7 | 100 | 0.43204 | 0 | |
HVG01 (TURQUOISE-1 BULK) | FTS INTERNATIONAL | Gelling Agent | Petroleum Distillate Hydrotreated Light | 064742-47-8 | 55 | 0.08438 | 0 | |
Crystalline Silica (Quartz Sand, Silicon Dioxide) | 014808-60-7 | 2 | 0.00307 | 0 | ||||
Guar Gum | 009000-30-0 | 50 | 0.07671 | 0 | ||||
Surfactant | 068439-51-0 | 2 | 0.00307 | 0 | ||||
CS-250 SI | FTS INTERNATIONAL | Scale Inhibitor | Ethylene Glycol | 000107-21-1 | 10 | 0.00129 | 0 | |
LTB-01 | FTS INTERNATIONAL | Breaker | Crystalline Silica (Quartz Sand, Silicon Dioxide) | 014808-60-7 | 25 | 0.01076 | 0 | |
Proprietary Cured Acrylic Resin | TRADE SECRET | 25 | 0.01076 | 0 | ||||
Ammonium Persulfate | 007727-54-0 | 100 | 0.04305 | 0 | ||||
CI-150 | FTS INTERNATIONAL | Corrosion Inhibitor | Proprietary Quaternary Ammonium Compound | TRADE SECRET | 10 | 0.00011 | 0 | |
Dimethyl Formamide | 000068-12-2 | 10 | 0.00011 | 0 | ||||
Proprietary Aromatic Aldehyde | TRADE SECRET | 10 | 0.00011 | 0 | ||||
Proprietary Organic Amine Resin Salt | TRADE SECRET | 30 | 0.00032 | 0 | ||||
Isopropanol (Isopropyl Alcohol, Propan-2-ol) | 000067-63-0 | 60 | 0.00065 | 0 | ||||
Fresh Water | CHESAPEAKE ENERGY | Carrier/Base Fluid | Water | 007732-18-5 | 100 | 82.7123 | 0 | |
10.1 - 15 HCL | FTS INTERNATIONAL | Acid | Water | 007732-18-5 | 85 | 0.04899 | 0 | |
Hydrochloric Acid | 007647-01-0 | 15 | 0.00864 | 0 | ||||
7.5pct HCl | FTS INTERNATIONAL | Acid | Water | 007732-18-5 | 93 | 0.50359 | 0 | |
Hydrochloric Acid | 007647-01-0 | 8 | 0.04083 | 0 | ||||
FRW-200 | FTS INTERNATIONAL | Friction Reducer | Petroleum Distillate Hydrotreated Light | 064742-47-8 | 26 | 0.01074 | 0 | |
ICI-3240 (1 GAL) | FTS INTERNATIONAL | Anti-Bacterial Agent | Sodium Hydroxide | 001310-73-2 | 4 | 0.00054 | 0 | |
Dazomet | 000533-74-4 | 24 | 0.00326 | 0 | ||||
Northern White Sand | FTS INTERNATIONAL | Proppant - Natural | Crystalline Silica (Quartz Sand, Silicon Dioxide) | 014808-60-7 | 100 | 15.4743 | 0 | |
APB01 (AMMONIUM PERSUFATE BREAKER) | FTS INTERNATIONAL | Breaker | Ammonium Persulfate | 007727-54-0 | 100 | 0.00007000 | 0 | |
Recycled Produced Water | CHESAPEAKE ENERGY | Carrier/Base Fluid | Water | 007732-18-5 | 100 | 0.44574 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2014-11-23 | H2O | 15 | 2476 Bbl | 401600 | Frac Tech Services | STAGE 31/31
25 SHOTS |
2014-11-12 | H2O | 15 | 3692 Bbl | 406000 | Frac Tech Services | STAGE 1/31
25 SHOTS STAGE 2-30 SEE IMAGES |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2015 | CHESAPEAKE EXPLORATION LLC | 520378 | 63581 | 325 |
2016 | CHESAPEAKE EXPLORATION LLC | 259303 | 22839 | 366 |
2017 | CHESAPEAKE EXPLORATION LLC | 182617 | 12811 | 345 |
2018 | CHESAPEAKE EXPLORATION LLC | 93042 | 6686 | 326 |
2019 | CHESAPEAKE EXPLORATION LLC | 22142 | 1519 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2015 | CHESAPEAKE EXPLORATION LLC | Brine | 26500 | 325 |
2016 | CHESAPEAKE EXPLORATION LLC | Brine | 5790 | 366 |
2017 | CHESAPEAKE EXPLORATION LLC | Brine | 4450 | 345 |
2018 | CHESAPEAKE EXPLORATION LLC | Brine | 9141 | 326 |
2019 | CHESAPEAKE EXPLORATION LLC | Brine | 1677 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1889442261 | 2017-3-2 0:00:0 | PL | No Violations | |
-2077328686 | 2018-11-19 0:00 | PW | No Violations | 1.00 |
0332798325 | 2014-02-03 | Drill / Deepen / Reopen | No Violations | I was on site to witness the cementing of the 20 inch conductor casing. My inspection revealed that Enviro Drill has drilled a 30 inch hole to a total depth of 120 feet and ran 120 of 20 inch conductor casing (78.67 pounds per foot / inside diameter of 19.25 inches). Allied pumped 433 sacks of Class A cement with 2% CaCl and 1/2 pound per sack floseal. The cement had a density of 15.6 pounds per gallon, a yield of 1.18 cubic feet per sack, and they used 5.23 gallons of mix water per sack. Allied pumped 91 barrels of cement slurry, 39.5 barrels of displacement, and there was 10 barrels of cement returns to surface. My inspection revealed no violations at this time. NOTE: Started pumping water on the 6H well and found the 2 inch ball valve on the conductor cap was split. Enviro Drill replaced the ball valve and Allied started pumping on the casing again. Had to shut down again because the weld on the conductor cap was leaking. They also found that the 5H and 10H conductor holes were communicating so they decided to pump this cement job first and then go back to the 5H and 10H conductor cement jobs. Region Supervisor Tom Hill was present for the cementing of the casing. |
1010857237 | 2019-12-9 0:00: | PW | No Violations | 0.80 |
1393923913 | 2014-03-04 | Drill / Deepen / Reopen | No Violations | Inspector James Bucksar and I were on site to witness the cementing of the 13 3/8 inch surface casing. Our inspection revealed that Nomac Drilling Rig # 71 has drilled a 17 1/2 inch hole to a total depth of 575 feet and ran 565 feet of 13 3/8 inch surface casing (54.5 pounds per foot / inside diameter is 12.615 inches). They installed 7 bowspring centralizers on the casing string on joints (2 on 1st, 2,3,6,9, and 12). Schlumberger cemented the casing with 514 sacks of Class A D901 with 1% D154, 0.5 B348, 0.15% B160A,, 0.2% D046, .125 pound per sack D130. The cement had a density of 15.6 pounds per gallon, a yield of 1.2 cubic feet per sack, and they used 5.219 gallons of mix water per sack. Schlumberger pumped 110 barrels of cement slurry, 80.5 barrels of displacement, and there was 21 barrels of cement returns to surface. They landed the plug with 275 PSI and bumped the pressure up to 728 PSI for the casing test. The casing test was approved, they released the pressure, the floats held, and there was 1/2 barrel of water flowed back when the pressure was released. Our inspection revealed no violations at this time. |
1394076265 | 2014-03-05 | Drill / Deepen / Reopen | No Violations | I was on site to witness the cementing of the 9 5/8 inch intermediate casing. My inspection revealed that Nomac Drilling Rig #71 has drilled a 12 1/4 inch hole to a total depth of 1896 feet and ran 1888 feet of 9 5/8 inch intermediate casing (40 pounds per foot / inside diameter 8.830 inches). They installed 17 bowspring centralizers on the casing string; 2 on 1st joint,2,3,6,9,12,15,18,21,24,27,30,33,36,39,and 42. O-TEX cemented the casing with 690 sacks of Class H with 3% Gypsum, 2% CaCl, 0.8% MC500,0.5% C45, and 0.4% C-41P. The cement had a density of 15.8 pounds per gallon, a yield of 1.21 cubic feet per sack, and they used 5.14 gallons of mix water per sack. O-TEX pumped 149 barrels of cement slurry, 133 barrels of displacement, and there was 28 barrels of cement returns to surface. They bumped the plug with 1110 PSI and then took the pressure up to 1606 PSI and conducted the casing test. The casing test was approved, pressure was released, floats held, and there was 3/4 barrel of water flowed back. My inspection revealed no violations at this time. |
1889442261 | 2017-03-02 | Preliminary Restoration | No Violations | I was on location to conduct a preliminary restoration inspection. The #6H well is in production and is equipped with plunger lift assembly. Jersey barriers were installed around the wellhead. The well is identified with a legibly-marked well identification sign. Identification was posted at the tank battery which consisted of eight 400 bbl production tanks, four labeled as containing produced water, and four labelled as containing condensate, and one low-pressure vertical separator. The tank battery is surrounded by a dike. There are e-stops outside the barriers, and the tanks are grounded, and have static dissipaters. There is a truck grounding area for trucks collecting condensate and/or produced water. Lightning protection and a windsock are installed on top of the production tanks. Production equipment on the well pad consisted of:
6 producing wells 8- 400 bbl production tanks, four labelled as containing fresh water, and four labelled as containing condensate 6 sand separators 6 gas processing units 1 low pressure vertical separator located inside of the dike 1 vapor recovery unit 1 horizontal separator, 1 compressor station 2 bullet tanks Jersey barriers are installed around the production equipment. The access road and man doors were locked. Drainage and erosion controls at the pad are in place and functioning. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. The pad has a crushed limestone surface, and is in good repair. The lease road was stable in in good repair. |
2077328686 | 2018-11-19 | Production Wells | No Violations | The well was equipped with a plunger-lift assembly. The surface/intermediate and intermediate/production annular gauges displayed readings of zero psi. I performed a walk-around inspection of the pad and erosional controls appeared functioning. No violations were observed at the time of inspection. |
332798325 | 2014-2-3 0:00:0 | DD | No Violations | 5.00 |
For data sources see[9]