Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-155-22621
 
| Well ID: 34-155-22621
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.2138222549, -80.879943639 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.21382225, -80.87994364 | width=100% | height=100% }}  
 
|-
 
|-
| County:
+
| County: [[Trumbull County, Ohio|Trumbull]]
 
|-
 
|-
| Municipality:
+
| Municipality:  
 
|-
 
|-
| Operator Name:
+
| Operator Name: [[OHIO VALLEY ENERGY SYSTEM CORP]]
 
|-
 
|-
| Well Pad ID:
+
| Well Pad ID:  
 
|-
 
|-
| Farm/Lease Name:
+
| Farm/Lease Name:  
 
|-
 
|-
| First Permit Date:
+
| First Permit Date:  
 
|-
 
|-
| Last Permit Date:
+
| Last Permit Date:  
 
|-
 
|-
 
| Spud Date: 1984-10-15
 
| Spud Date: 1984-10-15
 
|-
 
|-
| Unconventional:
+
| Unconventional: No
 
|-
 
|-
| Horizontal:
+
| Configuration: Vertical
 
|-
 
|-
| Producing: No
+
| Well Status: Producing
 
|-
 
|-
 
| Violations: 0
 
| Violations: 0
 
|-
 
|-
| Latitude: 41.2138222549
+
| Latitude: 41.21382225
 
|-
 
|-
| Longitude: -80.879943639
+
| Longitude: -80.87994364
 
|-
 
|-
 
|}
 
|}
Line 43: Line 43:
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL PRODUCTION DAYS
 
!scope="col" | OIL PRODUCTION DAYS
 +
|-
 +
| 1985-0
 +
| style="text-align:right;" | 6063.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 332.0
 +
|
 +
|-
 +
|-
 +
| 1986-0
 +
| style="text-align:right;" | 13164.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 282.0
 +
|
 +
|-
 +
|-
 +
| 1987-0
 +
| style="text-align:right;" | 8629.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 198.0
 +
|
 +
|-
 +
|-
 +
| 1988-0
 +
| style="text-align:right;" | 13444.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 528.0
 +
|
 +
|-
 +
|-
 +
| 1989-0
 +
| style="text-align:right;" | 9407.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 352.0
 +
|
 +
|-
 +
|-
 +
| 1990-0
 +
| style="text-align:right;" | 21603.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 530.0
 +
|
 +
|-
 +
|-
 +
| 1991-0
 +
| style="text-align:right;" | 15434.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 462.0
 +
|
 +
|-
 +
|-
 +
| 1992-0
 +
| style="text-align:right;" | 12826.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 300.0
 +
|
 +
|-
 +
|-
 +
| 1993-0
 +
| style="text-align:right;" | 10472.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 180.0
 +
|
 +
|-
 +
|-
 +
| 1994-0
 +
| style="text-align:right;" | 8964.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 147.0
 +
|
 +
|-
 +
|-
 +
| 1995-0
 +
| style="text-align:right;" | 7015.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 144.0
 +
|
 +
|-
 +
|-
 +
| 1996-0
 +
| style="text-align:right;" | 1542.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 0.0
 +
|
 +
|-
 +
|-
 +
| 1997-0
 +
| style="text-align:right;" | 7843.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 109.0
 +
|
 +
|-
 +
|-
 +
| 1998-0
 +
| style="text-align:right;" | 8210.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 130.0
 +
|
 +
|-
 +
|-
 +
| 1999-0
 +
| style="text-align:right;" | 6838.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 88.0
 +
|
 +
|-
 +
|-
 +
| 2000-0
 +
| style="text-align:right;" | 6660.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 145.0
 +
|
 +
|-
 +
|-
 +
| 2001-0
 +
| style="text-align:right;" | 5251.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 96.0
 +
|
 +
|-
 +
|-
 +
| 2002-0
 +
| style="text-align:right;" | 1312.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 65.0
 +
|
 +
|-
 +
|-
 +
| 2003-0
 +
| style="text-align:right;" | 4585.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 36.0
 +
|
 +
|-
 +
|-
 +
| 2004-0
 +
| style="text-align:right;" | 5281.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 93.0
 +
|
 +
|-
 +
|-
 +
| 2005-0
 +
| style="text-align:right;" | 4757.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 121.0
 +
|
 +
|-
 +
|-
 +
| 2006-0
 +
| style="text-align:right;" | 4795.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 73.0
 +
|
 +
|-
 +
|-
 +
| 2007-0
 +
| style="text-align:right;" | 4290.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 28.0
 +
|
 +
|-
 +
|-
 +
| 2008-0
 +
| style="text-align:right;" | 4778.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 60.0
 +
|
 +
|-
 +
|-
 +
| 2013-0
 +
| style="text-align:right;" | 2731.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 38.0
 +
|
 +
|-
 +
|-
 +
| 2014-0
 +
| style="text-align:right;" | 4205.0
 +
| style="text-align:right;" | 365.0
 +
|
 +
|
 +
| style="text-align:right;" | 101.0
 +
| style="text-align:right;" | 365.0
 +
|-
 
|}
 
|}
== Waste Data ==
+
For data sources see<ref>{{cite web
{| class="wikitable sortable" width="95%"
+
| title = Ohio Department of Natural Resources RBDMS
!scope="col" | PERIOD
+
| publisher = [http://oilandgas.ohiodnr.gov/]
!scope="col" | TYPE
+
| date = 2015-06-19
!scope="col" | QUANTITY
+
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Production
!scope="col" | UNITS
+
| accessdate = 2015-06-20 }}</ref>
!scope="col" | DISPOSAL METHOD
 
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
|}
 
 
== Inspection Data ==
 
== Inspection Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 64: Line 292:
 
!scope="col" | VIOLATION ID
 
!scope="col" | VIOLATION ID
 
!scope="col" | VIOLATION CODE
 
!scope="col" | VIOLATION CODE
!scope="col" | VIOLATION_COMMENT
+
!scope="col" | VIOLATION COMMENT
 +
|-
 +
| 1375273800
 +
| 2013-07-17
 +
|
 +
| My inspection found the well in production.  The well was equipped with a plunger lift unit.  I noticed a flow line leak approximately 15' northeast of the wellhead in a 10' x 3' water puddle.  The tank battery contained a 100 barrel production tank, a 50 barrel brine tank, and a separator.  The dike was weathered and not capable of meeting containment requirements.  There was a plug on the load line.  Identification signs were posted on the production tank and well.  There was a 7 day production chart at the separator.  The lease road was in good condition.  I called Don Nething at 330-283-5758.  I instructed him to send the well tender to isolate the leak and make repair to the flow line.  Also, I told him to build a new dike capable of meeting containment requirements.
 +
|
 +
|
 +
|
 +
|-
 
|-
 
|-
 
| -1751297846
 
| -1751297846
 
| 2013-07-30
 
| 2013-07-30
|
+
|  
 
| My inspection found the flow line leak repaired per my request.
 
| My inspection found the flow line leak repaired per my request.
|
+
|  
|
+
|  
|
+
|  
|-
 
|-
 
| 1375273800
 
| 2013-07-17
 
|
 
| My inspection found the well in production.  The well was equipped with a plunger lift unit.  I noticed a flow line leak approximately 15' northeast of the wellhead in a 10' x 3' water puddle.  The tank battery contained a 100 barrel production tank, a 50 barrel brine tank, and a separator.  The dike was weathered and not capable of meeting containment requirements.  There was a plug on the load line.  Identification signs were posted on the production tank and well.  There was a 7 day production chart at the separator.  The lease road was in good condition.  I called Don Nething at 330-283-5758.  I instructed him to send the well tender to isolate the leak and make repair to the flow line.  Also, I told him to build a new dike capable of meeting containment requirements.
 
|
 
|
 
|
 
 
|-
 
|-
 
|-
 
|-
 
| PL3690
 
| PL3690
|
+
|  
|
+
|  
 
| Preliminary Restoration  done information from Data Point
 
| Preliminary Restoration  done information from Data Point
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Ohio Department of Natural Resources RBDMS
 +
| publisher = [http://oilandgas.ohiodnr.gov/]
 +
| date = 2015-06-19
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection
 +
| accessdate = 2015-06-20 }}</ref>
 +
== References ==
 +
{{reflist}}
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 
[[Category:Wells]]
 
[[Category:Wells]]

Revision as of 07:56, 15 July 2015

Well Details

Well ID: 34-155-22621
Loading map...
County: Trumbull
Municipality:
Operator Name: OHIO VALLEY ENERGY SYSTEM CORP
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1984-10-15
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.21382225
Longitude: -80.87994364

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1985-0 6063.0 332.0
1986-0 13164.0 282.0
1987-0 8629.0 198.0
1988-0 13444.0 528.0
1989-0 9407.0 352.0
1990-0 21603.0 530.0
1991-0 15434.0 462.0
1992-0 12826.0 300.0
1993-0 10472.0 180.0
1994-0 8964.0 147.0
1995-0 7015.0 144.0
1996-0 1542.0 0.0
1997-0 7843.0 109.0
1998-0 8210.0 130.0
1999-0 6838.0 88.0
2000-0 6660.0 145.0
2001-0 5251.0 96.0
2002-0 1312.0 65.0
2003-0 4585.0 36.0
2004-0 5281.0 93.0
2005-0 4757.0 121.0
2006-0 4795.0 73.0
2007-0 4290.0 28.0
2008-0 4778.0 60.0
2013-0 2731.0 38.0
2014-0 4205.0 365.0 101.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1375273800 2013-07-17 My inspection found the well in production. The well was equipped with a plunger lift unit. I noticed a flow line leak approximately 15' northeast of the wellhead in a 10' x 3' water puddle. The tank battery contained a 100 barrel production tank, a 50 barrel brine tank, and a separator. The dike was weathered and not capable of meeting containment requirements. There was a plug on the load line. Identification signs were posted on the production tank and well. There was a 7 day production chart at the separator. The lease road was in good condition. I called Don Nething at 330-283-5758. I instructed him to send the well tender to isolate the leak and make repair to the flow line. Also, I told him to build a new dike capable of meeting containment requirements.
-1751297846 2013-07-30 My inspection found the flow line leak repaired per my request.
PL3690 Preliminary Restoration done information from Data Point

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 