If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 34-167-27958 | | Well ID: 34-167-27958 | ||
− | | style="height=100%; align=center" rowspan="15" | {{#display_map: 39. | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 39.41370602, -81.65773857 | width=100% | height=100% }} |
|- | |- | ||
− | | County: | + | | County: [[Washington County, Ohio|Washington]] |
|- | |- | ||
− | | Municipality: | + | | Municipality: |
|- | |- | ||
− | | Operator Name: | + | | Operator Name: [[CARPER WELL SERVICE]] |
|- | |- | ||
− | | Well Pad ID: | + | | Well Pad ID: |
|- | |- | ||
− | | Farm/Lease Name: | + | | Farm/Lease Name: |
|- | |- | ||
− | | First Permit Date: | + | | First Permit Date: |
|- | |- | ||
− | | Last Permit Date: | + | | Last Permit Date: |
|- | |- | ||
| Spud Date: 1984-12-23 | | Spud Date: 1984-12-23 | ||
|- | |- | ||
− | | Unconventional: | + | | Unconventional: No |
|- | |- | ||
− | | | + | | Configuration: Vertical |
|- | |- | ||
− | | | + | | Well Status: Active Injection |
|- | |- | ||
− | | Violations: | + | | Violations: 0 |
|- | |- | ||
− | | Latitude: 39. | + | | Latitude: 39.41370602 |
|- | |- | ||
− | | Longitude: -81. | + | | Longitude: -81.65773857 |
|- | |- | ||
|} | |} | ||
Line 43: | Line 43: | ||
!scope="col" | OIL QUANTITY | !scope="col" | OIL QUANTITY | ||
!scope="col" | OIL PRODUCTION DAYS | !scope="col" | OIL PRODUCTION DAYS | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | - | + | | 1992-0 |
− | | | + | | style="text-align:right;" | 1906.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 17.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2001-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 100.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2002-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 100.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2003-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 80.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2004-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 79.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2005-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 75.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2006-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 70.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2007-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 75.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2008-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 20.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2011-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 10.0 |
− | | | + | | |
|- | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Ohio Department of Natural Resources RBDMS | ||
+ | | publisher = [http://oilandgas.ohiodnr.gov/] | ||
+ | | date = 2015-06-19 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Production | ||
+ | | accessdate = 2015-06-20 }}</ref> | ||
+ | == Inspection Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | INSPECTION ID | ||
+ | !scope="col" | DATE | ||
+ | !scope="col" | DESCRIPTION | ||
+ | !scope="col" | COMMENT | ||
+ | !scope="col" | VIOLATION ID | ||
+ | !scope="col" | VIOLATION CODE | ||
+ | !scope="col" | VIOLATION COMMENT | ||
|- | |- | ||
− | | | + | | 1076431758 |
− | | | + | | 2004-02-10 |
− | | | + | | |
− | | Inspection this day found | + | | Inspection this day found no violations, well capable of producing with jack, belt off motor but can be put back on, tank area clean, fresh water in pit, ID's good, good dike |
− | | | + | | |
− | | | + | | |
− | | | + | | Compliance Notice |
|- | |- | ||
|- | |- | ||
− | | | + | | 1083859212 |
− | | | + | | 2004-05-06 |
− | | | + | | |
− | | | + | | Reinspect this well as last time visited was oily mess - pin hole in line at well to flowline - well not capable of producing. Today, hole fixed, still a little oily but much better, well capable of producing - have fixed jack. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1168715853 |
− | | 2010- | + | | 2010-03-09 |
− | | | + | | |
− | | Inspection found | + | | Inspection this day found pump running, 370# on tubing, 0# on annulus. Good ID's at pump house and at well, small amount of fluid in dike area but they are working on clearing that. Very muddy, had to walk in. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | | + | | 1237389802 |
− | | | + | | 2009-03-18 |
− | | | + | | |
− | | | + | | Running packer in well this day. Running a Halliburton R-4 tension packer - rebuilt - on 2 7/8 tubing. Packer appears in good working order and watched go in hole. Bond log shows cement on backside of 4.5 casing to 1479'. 3/19/2009 - Packer set at 1773' - had originally put in 16' more but had to be pulled when packer wouldn't set. Well passed integrity test at 600# for 15 minutes. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1275774418 |
− | | | + | | 2015-05-29 |
− | | | + | | |
− | | | + | | On site to witness MIT Testing of annulus of tubing and ensuring that they have good casing integrity company rep applied 585 psi of pressure and we monitored pressure for 15 minutes with no decline in pressures.(TEST PASSED) |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | | + | | 1312230760 |
− | | | + | | 2011-07-27 |
− | | | + | | |
− | | | + | | Inspection this day found facility still down due to brine escape outside the dike. Appears brine kill area has not been treated with lime or re-seeded. Have heard facility is for sale but believe they need to follow thru on their violation. Oil very heavy on gravel inside dike - this should all be cleaned up - seems to be short-lived when it does get resolved. Will continue to monitor. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1336326888 |
− | | | + | | 2002-03-14 |
− | | | + | | |
− | | | + | | |
− | + | | | |
− | + | | | |
− | | | + | | |
− | | | ||
− | | | ||
|- | |- | ||
|- | |- | ||
− | | - | + | | -1367615308 |
− | | 2013- | + | | 2013-08-20 |
− | | | + | | |
− | | | + | | On site to witness clean up efforts being made at site, owner is removing material from tank area and hauling it to a approved landfill and once all solids and liquids are removed they will remove tanks and then start rebuilding process of entire storage facility. |
− | + | | | |
− | + | | | |
− | | | + | | |
− | | | ||
− | | | ||
|- | |- | ||
|- | |- | ||
− | | | + | | 1381300462 |
− | | | + | | 2015-03-02 |
− | | | + | | |
− | | Inspection revealed that | + | | Inspection revealed that well is not in operation at this time, owner has rebuilt facility and they are waiting on better weather so they can cover exposed portions of containment liner so it wont rot due to exposure to the sunlight. |
− | + | | | |
− | + | | | |
− | | | + | | |
− | | | ||
− | | | ||
|- | |- | ||
|- | |- | ||
− | | - | + | | -14118249 |
− | | | + | | 2014-09-15 |
− | | | + | | |
− | | Inspection revealed that | + | | Inspection revealed that owner has nearly completed rework project at site and I informed him that flow line would need to be tested along with performing annulus test on tubing to ensure the division that they still have good casing integrity. |
− | + | | | |
− | + | | | |
− | | | + | | |
− | | | ||
− | | | ||
|- | |- | ||
|- | |- | ||
− | | - | + | | -143082761 |
− | | | + | | 2014-05-12 |
− | | | + | | |
− | | Inspection | + | | Inspection revealed that owner has two more old tanks to be removed from site before they can start setting new storage tanks in dike area and it was discussed that they will replace flow line going to well head before placing well into operation. |
− | + | | | |
− | + | | | |
− | + | | | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | | | ||
− | | | ||
|- | |- | ||
|- | |- | ||
| 1455390301 | | 1455390301 | ||
| 2014-03-10 | | 2014-03-10 | ||
− | | | + | | |
| Inspection revealed that well is down waiting on owner to complete rebuilding of storage tank facility. | | Inspection revealed that well is down waiting on owner to complete rebuilding of storage tank facility. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1584860842 | ||
+ | | 2009-12-01 | ||
+ | | | ||
+ | | Inspection this day found pump not running, pressures were 320# on tubing, 0# on annulus. No ID's at well or on house - asked operator to get ID's up and would recheck next week. Reclamation has been done on this well and looks very nice - grass growing. 12/7/09 - ID's now up at well, will add sticker at pump house. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 1655151667 | | 1655151667 | ||
| 2013-12-03 | | 2013-12-03 | ||
− | | | + | | |
| Owner is presently placing sand on top of liner making preparation for spotting of new storage tanks when are delivered. | | Owner is presently placing sand on top of liner making preparation for spotting of new storage tanks when are delivered. | ||
Note: Before placing well back into operation we will need to perform pressure test on annulus of tubing. | Note: Before placing well back into operation we will need to perform pressure test on annulus of tubing. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1670145972 | ||
+ | | 2002-03-14 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -1724166923 | ||
+ | | 2015-03-23 | ||
+ | | | ||
+ | | Inspection revealed that owner has completed remedial work required at site and is ready to place wells on the lease back into operation. | ||
+ | Note: Witnessed MIT testing on annulus of tubing today owner applied 550 psi and we monitored pressure for 15 minutes with no decline in pressure. | ||
+ | Dike measurements are as follows 25'X50'X48TALL with a calculated volume of 888 bbl. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 1728242773 | | 1728242773 | ||
| 2013-02-12 | | 2013-02-12 | ||
− | | | + | | |
| Inspection revealed that well is not in operation at this time, walked flow line to check for leaks none were found. | | Inspection revealed that well is not in operation at this time, walked flow line to check for leaks none were found. | ||
Note: Called company and requested that they have positive pressure applied to annulus of tubing and also remove fresh water build up in tank area. | Note: Called company and requested that they have positive pressure applied to annulus of tubing and also remove fresh water build up in tank area. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1947441163 | | 1947441163 | ||
| 2012-04-12 | | 2012-04-12 | ||
− | | | + | | |
| Inspection revealed that injection pump was not in operation today and it appears that well has been out of service for quite some time, it has been noted that Green Hunter is working on service agreement with Carper to operate well and clean up existing issues at facility. | | Inspection revealed that injection pump was not in operation today and it appears that well has been out of service for quite some time, it has been noted that Green Hunter is working on service agreement with Carper to operate well and clean up existing issues at facility. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1947703385 | | 1947703385 | ||
| 2012-03-05 | | 2012-03-05 | ||
− | | | + | | |
| My inspection this day is routine - facility still has citation, no changes have been made. The dike area this day full of fresh rain water. Hopefully, Triad will get started soon and reworking the site and get wells into production. | | My inspection this day is routine - facility still has citation, no changes have been made. The dike area this day full of fresh rain water. Hopefully, Triad will get started soon and reworking the site and get wells into production. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1967576347 | | 1967576347 | ||
| 2011-11-23 | | 2011-11-23 | ||
− | | | + | | |
| My inspection this day found facility was still down. Fresh water, about 1' deep, is inside the diked area. This is due to heavy rains in last few days. The operator has been pumping area out. The brine kill area is growing back slowly. Proper identification is posted. The Notice of Violation cannot be resolved yet. Did not go to well this day. | | My inspection this day found facility was still down. Fresh water, about 1' deep, is inside the diked area. This is due to heavy rains in last few days. The operator has been pumping area out. The brine kill area is growing back slowly. Proper identification is posted. The Notice of Violation cannot be resolved yet. Did not go to well this day. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 2012194893 | | 2012194893 | ||
| 2013-10-04 | | 2013-10-04 | ||
− | | | + | | |
| Clean up continues at site owner has removed all storage tanks from dike area and is in process of removing all contaminated material from dike area and once all material is removed they will begin rebuilding facility. | | Clean up continues at site owner has removed all storage tanks from dike area and is in process of removing all contaminated material from dike area and once all material is removed they will begin rebuilding facility. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 2022100403 | | 2022100403 | ||
| 2013-09-09 | | 2013-09-09 | ||
− | | | + | | |
| Clean up continues within tank area. | | Clean up continues within tank area. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 2038859740 | | 2038859740 | ||
| 2003-02-11 | | 2003-02-11 | ||
− | | | + | | |
| no violations noted day of inspection. | | no violations noted day of inspection. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -2070598164 | ||
+ | | 2013-03-18 | ||
+ | | | ||
+ | | Inspection revealed that well was not in operation and owner still needs to have tanks removed and cleaned out and containment area fixed up and drains from pump house plumbed to vault area. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -2094693522 | ||
+ | | 2009-05-29 | ||
+ | | | ||
+ | | Inspection this day found well/pump not in use. Walked out to well, checked pressures. ID's still needed at well, on pumphouse building and tanks for this well. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -210520627 | ||
+ | | 2010-05-25 | ||
+ | | | ||
+ | | Inspection this day found pump not running, good ID's at well and pump, skim of oil on pit at tanks, #530 on tubing, 0 on annulus. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 269531335 | | 269531335 | ||
| 2013-11-04 | | 2013-11-04 | ||
− | | | + | | |
| Inspection on this day indicated that owner is presently installing new pit liner in tank area and placing sand on top of liner to help hold it in place. | | Inspection on this day indicated that owner is presently installing new pit liner in tank area and placing sand on top of liner to help hold it in place. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -29708929 | ||
+ | | 2014-09-23 | ||
+ | | | ||
+ | | On site to hydro test new flow line and pressure test annulus of tubing company rep pumped fresh water through flow line and we tested it at 560 psi with no decline in pressure and then we moved on to performing annulus testing they placed 530 psi on annulus and we monitored pressure for 15 minutes with no decline in pressure. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 391114439 | | 391114439 | ||
| 2013-07-29 | | 2013-07-29 | ||
− | | | + | | |
| I stopped to look and see if the tank battery dike had been sucked out. Dike had been sucked out with the exception of a few small pools on the bottom. Brush has been cut around the whole site. | | I stopped to look and see if the tank battery dike had been sucked out. Dike had been sucked out with the exception of a few small pools on the bottom. Brush has been cut around the whole site. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -405741539 | ||
+ | | 2011-03-08 | ||
+ | | | ||
+ | | Inspection this day found pump not running, on pressure on well. Dike area has been pumped free of water, still an oily mess. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -42858509 | ||
+ | | 2011-05-24 | ||
+ | | | ||
+ | | Inspection this day found pump not running, dike area almost full of brine, fresh and skim of oil. Wrote violation on other well - applies to this well also - can called Carper and shut injection down until problems fixed. Large brine kill about 100 x 25' below and off to side of enpoundment - appears pit liner has a hole in it and brine moved under the brim of the dike and down into horse pasture. Millard says will address problems and call me with a plan. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -462431287 | ||
+ | | 2014-08-13 | ||
+ | | | ||
+ | | Inspection revealed that owner has recently placed two 100 bbl. tanks at site and they plan on setting more storage tanks in the near future and also they plan on replacing flow line to both wells on the lease before placing them back into operation. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -499467593 | ||
+ | | 2010-08-23 | ||
+ | | | ||
+ | | Inspection found well not in production, pump not running. Appears facility not getting much water, dike area needs pumped out with water with thin layer of oil on top. Called operator and asked he to get it cleaned out. No pressure on tubing or annulus. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -550908666 | ||
+ | | 2014-06-26 | ||
+ | | | ||
+ | | Inspection revealed that owner has removed old tanks from facility and they are waiting on new storage tanks to be delivered to site and placed in storage area. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -577391960 | ||
+ | | 2009-03-24 | ||
+ | | | ||
+ | | Well passed integrity test on 3/19/2009, holding pressure at 600#. Today, pressure testing the line - 2 3/8 steel line laid on top of ground - pressured up with injection pump to 560# - held and passed test. Will start injecting this afternoon. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -664843207 | ||
+ | | 2013-07-24 | ||
+ | | | ||
+ | | Accompanied UIC III inspector Dave Ball on inspection of this well and tank battery. The tank battery has an excessive amount of fluid in it with oily fluid on top. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -702846340 | ||
+ | | 2013-07-24 | ||
+ | | | ||
+ | | Inspection revealed that there was brine&oil within dike area and it appeared that someone had recently ran tanks over and owner has not complied with previous Compliance notice issued 5/24/11 for contamination at surface facility and dike not being liquid tight because it appears to be leaking because we ran Quantab test in water hole and they indicated that there was brine present outside of dike. | ||
+ | Note: Photo's were taken and water samples were taken to Cambridge lab to be analyzed, | ||
+ | Note: To properly fix dike owner will need to have tanks cleaned and removed from dike area and new liner installed after all contaminated material is removed from dike area and replaced with fresh soil. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 747898934 | | 747898934 | ||
| 2010-11-29 | | 2010-11-29 | ||
− | | | + | | |
| Inspection this day found pump not running, wells not in use. Pressures showed 0#. Tickets from brine haulers showed last water brought in 11/23/2010. Dike area contained small amt. fresh water, very little oil - they seem to be doing better job of keeping oil out of dike area. | | Inspection this day found pump not running, wells not in use. Pressures showed 0#. Tickets from brine haulers showed last water brought in 11/23/2010. Dike area contained small amt. fresh water, very little oil - they seem to be doing better job of keeping oil out of dike area. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -858871157 | ||
+ | | 2009-08-27 | ||
+ | | | ||
+ | | Inspection this day found Millard Carper changing filters, then starting pump up. Other well (#7401) still down. Pressure on this well to the limits - told him not to go any higher on the presssure - should reduce when get 2nd well going again. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 969939026 | | 969939026 | ||
| 2012-01-31 | | 2012-01-31 | ||
− | | | + | | |
| I met with John Jack and Dylan from Triad and Jeff Jones from J & L Water Services to discuss plans for re-working the site and resolving the violation. See #7401 for full inspection The wells are still not in production. | | I met with John Jack and Dylan from Triad and Jeff Jones from J & L Water Services to discuss plans for re-working the site and resolving the violation. See #7401 for full inspection The wells are still not in production. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -99312161 | ||
+ | | 2013-07-25 | ||
+ | | | ||
+ | | Obtained water sample from inside and outside of dike. I was able to obtain sample from dike by dipping water out of it. I had to use a large syringe to obtain the sample from outside of the dike. I tested the water outside of the dike with high range Quantab test strips, and it measured 5.4 on the strip which is representative of 1268 parts per million (ppm) cloride. I then put the samples on ice, and took them directly to Cambridge lab. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| PL1620 | | PL1620 | ||
− | | | + | | |
− | | | + | | |
| Preliminary Restoration done information from Data Point | | Preliminary Restoration done information from Data Point | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Ohio Department of Natural Resources RBDMS | ||
+ | | publisher = [http://oilandgas.ohiodnr.gov/] | ||
+ | | date = 2015-06-19 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection | ||
+ | | accessdate = 2015-06-20 }}</ref> | ||
+ | == References == | ||
+ | {{reflist}} | ||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
[[Category:Wells]] | [[Category:Wells]] |
Well ID: 34-167-27958 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.41370602,"lon":-81.65773857,"icon":""}]} |
County: Washington | |
Municipality: | |
Operator Name: CARPER WELL SERVICE | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1984-12-23 | |
Unconventional: No | |
Configuration: Vertical | |
Well Status: Active Injection | |
Violations: 0 | |
Latitude: 39.41370602 | |
Longitude: -81.65773857 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
1992-0 | 1906.0 | 17.0 | ||||
2001-0 | 0.0 | 100.0 | ||||
2002-0 | 0.0 | 100.0 | ||||
2003-0 | 0.0 | 80.0 | ||||
2004-0 | 0.0 | 79.0 | ||||
2005-0 | 0.0 | 75.0 | ||||
2006-0 | 0.0 | 70.0 | ||||
2007-0 | 0.0 | 75.0 | ||||
2008-0 | 0.0 | 20.0 | ||||
2011-0 | 0.0 | 10.0 |
For data sources see[1]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION COMMENT |
---|---|---|---|---|---|---|
1076431758 | 2004-02-10 | Inspection this day found no violations, well capable of producing with jack, belt off motor but can be put back on, tank area clean, fresh water in pit, ID's good, good dike | Compliance Notice | |||
1083859212 | 2004-05-06 | Reinspect this well as last time visited was oily mess - pin hole in line at well to flowline - well not capable of producing. Today, hole fixed, still a little oily but much better, well capable of producing - have fixed jack. | ||||
-1168715853 | 2010-03-09 | Inspection this day found pump running, 370# on tubing, 0# on annulus. Good ID's at pump house and at well, small amount of fluid in dike area but they are working on clearing that. Very muddy, had to walk in. | ||||
1237389802 | 2009-03-18 | Running packer in well this day. Running a Halliburton R-4 tension packer - rebuilt - on 2 7/8 tubing. Packer appears in good working order and watched go in hole. Bond log shows cement on backside of 4.5 casing to 1479'. 3/19/2009 - Packer set at 1773' - had originally put in 16' more but had to be pulled when packer wouldn't set. Well passed integrity test at 600# for 15 minutes. | ||||
-1275774418 | 2015-05-29 | On site to witness MIT Testing of annulus of tubing and ensuring that they have good casing integrity company rep applied 585 psi of pressure and we monitored pressure for 15 minutes with no decline in pressures.(TEST PASSED) | ||||
1312230760 | 2011-07-27 | Inspection this day found facility still down due to brine escape outside the dike. Appears brine kill area has not been treated with lime or re-seeded. Have heard facility is for sale but believe they need to follow thru on their violation. Oil very heavy on gravel inside dike - this should all be cleaned up - seems to be short-lived when it does get resolved. Will continue to monitor. | ||||
-1336326888 | 2002-03-14 | |||||
-1367615308 | 2013-08-20 | On site to witness clean up efforts being made at site, owner is removing material from tank area and hauling it to a approved landfill and once all solids and liquids are removed they will remove tanks and then start rebuilding process of entire storage facility. | ||||
1381300462 | 2015-03-02 | Inspection revealed that well is not in operation at this time, owner has rebuilt facility and they are waiting on better weather so they can cover exposed portions of containment liner so it wont rot due to exposure to the sunlight. | ||||
-14118249 | 2014-09-15 | Inspection revealed that owner has nearly completed rework project at site and I informed him that flow line would need to be tested along with performing annulus test on tubing to ensure the division that they still have good casing integrity. | ||||
-143082761 | 2014-05-12 | Inspection revealed that owner has two more old tanks to be removed from site before they can start setting new storage tanks in dike area and it was discussed that they will replace flow line going to well head before placing well into operation. | ||||
1455390301 | 2014-03-10 | Inspection revealed that well is down waiting on owner to complete rebuilding of storage tank facility. | ||||
-1584860842 | 2009-12-01 | Inspection this day found pump not running, pressures were 320# on tubing, 0# on annulus. No ID's at well or on house - asked operator to get ID's up and would recheck next week. Reclamation has been done on this well and looks very nice - grass growing. 12/7/09 - ID's now up at well, will add sticker at pump house. | ||||
1655151667 | 2013-12-03 | Owner is presently placing sand on top of liner making preparation for spotting of new storage tanks when are delivered.
Note: Before placing well back into operation we will need to perform pressure test on annulus of tubing. |
||||
-1670145972 | 2002-03-14 | |||||
-1724166923 | 2015-03-23 | Inspection revealed that owner has completed remedial work required at site and is ready to place wells on the lease back into operation.
Note: Witnessed MIT testing on annulus of tubing today owner applied 550 psi and we monitored pressure for 15 minutes with no decline in pressure. Dike measurements are as follows 25'X50'X48TALL with a calculated volume of 888 bbl. |
||||
1728242773 | 2013-02-12 | Inspection revealed that well is not in operation at this time, walked flow line to check for leaks none were found.
Note: Called company and requested that they have positive pressure applied to annulus of tubing and also remove fresh water build up in tank area. |
||||
1947441163 | 2012-04-12 | Inspection revealed that injection pump was not in operation today and it appears that well has been out of service for quite some time, it has been noted that Green Hunter is working on service agreement with Carper to operate well and clean up existing issues at facility. | ||||
1947703385 | 2012-03-05 | My inspection this day is routine - facility still has citation, no changes have been made. The dike area this day full of fresh rain water. Hopefully, Triad will get started soon and reworking the site and get wells into production. | ||||
1967576347 | 2011-11-23 | My inspection this day found facility was still down. Fresh water, about 1' deep, is inside the diked area. This is due to heavy rains in last few days. The operator has been pumping area out. The brine kill area is growing back slowly. Proper identification is posted. The Notice of Violation cannot be resolved yet. Did not go to well this day. | ||||
2012194893 | 2013-10-04 | Clean up continues at site owner has removed all storage tanks from dike area and is in process of removing all contaminated material from dike area and once all material is removed they will begin rebuilding facility. | ||||
2022100403 | 2013-09-09 | Clean up continues within tank area. | ||||
2038859740 | 2003-02-11 | no violations noted day of inspection. | ||||
-2070598164 | 2013-03-18 | Inspection revealed that well was not in operation and owner still needs to have tanks removed and cleaned out and containment area fixed up and drains from pump house plumbed to vault area. | ||||
-2094693522 | 2009-05-29 | Inspection this day found well/pump not in use. Walked out to well, checked pressures. ID's still needed at well, on pumphouse building and tanks for this well. | ||||
-210520627 | 2010-05-25 | Inspection this day found pump not running, good ID's at well and pump, skim of oil on pit at tanks, #530 on tubing, 0 on annulus. | ||||
269531335 | 2013-11-04 | Inspection on this day indicated that owner is presently installing new pit liner in tank area and placing sand on top of liner to help hold it in place. | ||||
-29708929 | 2014-09-23 | On site to hydro test new flow line and pressure test annulus of tubing company rep pumped fresh water through flow line and we tested it at 560 psi with no decline in pressure and then we moved on to performing annulus testing they placed 530 psi on annulus and we monitored pressure for 15 minutes with no decline in pressure. | ||||
391114439 | 2013-07-29 | I stopped to look and see if the tank battery dike had been sucked out. Dike had been sucked out with the exception of a few small pools on the bottom. Brush has been cut around the whole site. | ||||
-405741539 | 2011-03-08 | Inspection this day found pump not running, on pressure on well. Dike area has been pumped free of water, still an oily mess. | ||||
-42858509 | 2011-05-24 | Inspection this day found pump not running, dike area almost full of brine, fresh and skim of oil. Wrote violation on other well - applies to this well also - can called Carper and shut injection down until problems fixed. Large brine kill about 100 x 25' below and off to side of enpoundment - appears pit liner has a hole in it and brine moved under the brim of the dike and down into horse pasture. Millard says will address problems and call me with a plan. | ||||
-462431287 | 2014-08-13 | Inspection revealed that owner has recently placed two 100 bbl. tanks at site and they plan on setting more storage tanks in the near future and also they plan on replacing flow line to both wells on the lease before placing them back into operation. | ||||
-499467593 | 2010-08-23 | Inspection found well not in production, pump not running. Appears facility not getting much water, dike area needs pumped out with water with thin layer of oil on top. Called operator and asked he to get it cleaned out. No pressure on tubing or annulus. | ||||
-550908666 | 2014-06-26 | Inspection revealed that owner has removed old tanks from facility and they are waiting on new storage tanks to be delivered to site and placed in storage area. | ||||
-577391960 | 2009-03-24 | Well passed integrity test on 3/19/2009, holding pressure at 600#. Today, pressure testing the line - 2 3/8 steel line laid on top of ground - pressured up with injection pump to 560# - held and passed test. Will start injecting this afternoon. | ||||
-664843207 | 2013-07-24 | Accompanied UIC III inspector Dave Ball on inspection of this well and tank battery. The tank battery has an excessive amount of fluid in it with oily fluid on top. | ||||
-702846340 | 2013-07-24 | Inspection revealed that there was brine&oil within dike area and it appeared that someone had recently ran tanks over and owner has not complied with previous Compliance notice issued 5/24/11 for contamination at surface facility and dike not being liquid tight because it appears to be leaking because we ran Quantab test in water hole and they indicated that there was brine present outside of dike.
Note: Photo's were taken and water samples were taken to Cambridge lab to be analyzed, Note: To properly fix dike owner will need to have tanks cleaned and removed from dike area and new liner installed after all contaminated material is removed from dike area and replaced with fresh soil. |
||||
747898934 | 2010-11-29 | Inspection this day found pump not running, wells not in use. Pressures showed 0#. Tickets from brine haulers showed last water brought in 11/23/2010. Dike area contained small amt. fresh water, very little oil - they seem to be doing better job of keeping oil out of dike area. | ||||
-858871157 | 2009-08-27 | Inspection this day found Millard Carper changing filters, then starting pump up. Other well (#7401) still down. Pressure on this well to the limits - told him not to go any higher on the presssure - should reduce when get 2nd well going again. | ||||
969939026 | 2012-01-31 | I met with John Jack and Dylan from Triad and Jeff Jones from J & L Water Services to discuss plans for re-working the site and resolving the violation. See #7401 for full inspection The wells are still not in production. | ||||
-99312161 | 2013-07-25 | Obtained water sample from inside and outside of dike. I was able to obtain sample from dike by dipping water out of it. I had to use a large syringe to obtain the sample from outside of the dike. I tested the water outside of the dike with high range Quantab test strips, and it measured 5.4 on the strip which is representative of 1268 parts per million (ppm) cloride. I then put the samples on ice, and took them directly to Cambridge lab. | ||||
PL1620 | Preliminary Restoration done information from Data Point |
For data sources see[2]