| Well ID: 34-105-23319 | | Well ID: 34-105-23319 | ||
− | | style="height=100%; align=center" rowspan="15" | {{#display_map: 39. | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 39.06257255, -82.05656588 | width=100% | height=100% }} |
|- | |- | ||
− | | County: | + | | County: [[Meigs County, Ohio|Meigs]] |
|- | |- | ||
− | | Municipality: | + | | Municipality: |
|- | |- | ||
− | | Operator Name: | + | | Operator Name: [[AMERICAN NATURAL GAS INC]] |
|- | |- | ||
− | | Well Pad ID: | + | | Well Pad ID: |
|- | |- | ||
− | | Farm/Lease Name: | + | | Farm/Lease Name: |
|- | |- | ||
− | | First Permit Date: | + | | First Permit Date: |
|- | |- | ||
− | | Last Permit Date: | + | | Last Permit Date: |
|- | |- | ||
| Spud Date: 1984-12-01 | | Spud Date: 1984-12-01 | ||
|- | |- | ||
− | | Unconventional: | + | | Unconventional: No |
|- | |- | ||
− | | | + | | Configuration: Vertical |
|- | |- | ||
− | | | + | | Well Status: Active Injection |
|- | |- | ||
− | | Violations: | + | | Violations: 0 |
|- | |- | ||
− | | Latitude: 39. | + | | Latitude: 39.06257255 |
|- | |- | ||
− | | Longitude: -82. | + | | Longitude: -82.05656588 |
|- | |- | ||
|} | |} | ||
Line 43: | Line 43: | ||
!scope="col" | OIL QUANTITY | !scope="col" | OIL QUANTITY | ||
!scope="col" | OIL PRODUCTION DAYS | !scope="col" | OIL PRODUCTION DAYS | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | - | + | | 1988-0 |
− | | | + | | style="text-align:right;" | 5871.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 416.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2000-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 463.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2001-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 305.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2002-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 58.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2003-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 131.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2004-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 19.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2005-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 63.0 |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | 2006-0 |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | style="text-align:right;" | 0.0 |
− | | | + | | |
|- | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Ohio Department of Natural Resources RBDMS | ||
+ | | publisher = [http://oilandgas.ohiodnr.gov/] | ||
+ | | date = 2015-06-19 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Production | ||
+ | | accessdate = 2015-06-20 }}</ref> | ||
+ | == Inspection Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | INSPECTION ID | ||
+ | !scope="col" | DATE | ||
+ | !scope="col" | DESCRIPTION | ||
+ | !scope="col" | COMMENT | ||
+ | !scope="col" | VIOLATION ID | ||
+ | !scope="col" | VIOLATION CODE | ||
+ | !scope="col" | VIOLATION COMMENT | ||
|- | |- | ||
− | | - | + | | -101835701 |
− | | | + | | 2014-11-19 |
− | | | + | | |
− | | | + | | No noted violations at facility. |
− | | | + | | |
− | | | + | | |
− | | | + | | Compliance Notice |
|- | |- | ||
|- | |- | ||
− | | - | + | | -101835701 |
− | | | + | | 2014-11-19 |
− | | | + | | |
− | | | + | | No noted violations at facility. |
− | | | + | | |
− | | | + | | |
− | | | + | | Phone Call |
|- | |- | ||
|- | |- | ||
− | | - | + | | -101835701 |
− | | | + | | 2014-11-19 |
− | | | + | | |
− | | | + | | No noted violations at facility. |
− | | | + | | |
− | | | + | | |
− | | | + | | Phone Call |
|- | |- | ||
|- | |- | ||
− | | - | + | | -101835701 |
− | | | + | | 2014-11-19 |
− | | | + | | |
− | | | + | | No noted violations at facility. |
− | | | + | | |
− | | | + | | |
− | | | + | | Phone Call |
|- | |- | ||
|- | |- | ||
− | | - | + | | -101835701 |
− | | | + | | 2014-11-19 |
− | | | + | | |
− | | | + | | No noted violations at facility. |
− | | | + | | |
− | | | + | | |
− | | | + | | Field Visit or Inspection |
|- | |- | ||
|- | |- | ||
− | | - | + | | -101835701 |
− | | | + | | 2014-11-19 |
− | | | + | | |
− | | | + | | No noted violations at facility. |
− | | | + | | |
− | | | + | | |
− | | | + | | Field Visit or Inspection |
|- | |- | ||
|- | |- | ||
− | | - | + | | -101835701 |
− | | | + | | 2014-11-19 |
− | | | + | | |
− | | | + | | No noted violations at facility. |
− | | | + | | |
− | | | + | | |
− | | | + | | Field Visit or Inspection |
|- | |- | ||
|- | |- | ||
− | | - | + | | -101835701 |
− | | | + | | 2014-11-19 |
− | | | + | | |
− | | No violations | + | | No noted violations at facility. |
− | | | + | | |
− | | | + | | |
− | | | + | | Compliance Notice |
|- | |- | ||
|- | |- | ||
− | | - | + | | -101835701 |
− | | | + | | 2014-11-19 |
− | | | + | | |
− | | | + | | No noted violations at facility. |
− | | | + | | |
− | | | + | | |
− | | | + | | Field Visit or Inspection |
|- | |- | ||
|- | |- | ||
− | | - | + | | -101835701 |
− | | | + | | 2014-11-19 |
− | | | + | | |
− | | | + | | No noted violations at facility. |
− | | | + | | |
− | | | + | | |
− | | | + | | Field Visit or Inspection |
|- | |- | ||
|- | |- | ||
− | | - | + | | -101835701 |
− | | 2014- | + | | 2014-11-19 |
− | | | + | | |
− | | No noted violations | + | | No noted violations at facility. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | -101835701 |
− | | | + | | 2014-11-19 |
− | | | + | | |
− | | No violations | + | | No noted violations at facility. |
− | | | + | | |
− | | | + | | |
− | | | + | | Compliance Notice |
|- | |- | ||
|- | |- | ||
− | | - | + | | -101835701 |
− | | | + | | 2014-11-19 |
− | | | + | | |
− | | No violations | + | | No noted violations at facility. |
− | | | + | | |
− | | | + | | |
− | | | + | | Compliance Notice |
|- | |- | ||
|- | |- | ||
− | | - | + | | -101835701 |
− | | | + | | 2014-11-19 |
− | | | + | | |
− | | | + | | No noted violations at facility. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | -101835701 |
− | | | + | | 2014-11-19 |
− | | | + | | |
− | | No violations. | + | | No noted violations at facility. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | -101835701 |
− | | | + | | 2014-11-19 |
− | | | + | | |
− | | | + | | No noted violations at facility. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | -101835701 |
− | | | + | | 2014-11-19 |
− | | | + | | |
− | | | + | | No noted violations at facility. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1019317996 |
− | | | + | | 2005-05-06 |
− | | | + | | |
− | | | + | | Pump was off, while the readings were taken. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | -1034071380 |
− | | | + | | 2005-08-04 |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | - | + | | -104043520 |
− | | | + | | 2004-10-08 |
− | + | | | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
| There were no violations at the time of inspection. | | There were no violations at the time of inspection. | ||
− | + | | | |
− | + | | | |
− | + | | | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | | | ||
− | | | ||
|- | |- | ||
|- | |- | ||
| 1070648922 | | 1070648922 | ||
| 2003-12-04 | | 2003-12-04 | ||
− | | | + | | |
| No violations at the time of inspection. | | No violations at the time of inspection. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1127139298 | | 1127139298 | ||
| 2005-08-10 | | 2005-08-10 | ||
− | | | + | | |
| Waited for cement bond log to be completed. Then, witnessed the packer installation. | | Waited for cement bond log to be completed. Then, witnessed the packer installation. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1149894788 | ||
+ | | 2006-10-17 | ||
+ | | | ||
+ | | No violations. Accompanied by Jon Scott. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -1158475857 | ||
+ | | 2007-07-17 | ||
+ | | | ||
+ | | There were no violations at the time. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 1167241693 | | 1167241693 | ||
| 2012-08-22 | | 2012-08-22 | ||
− | | | + | | |
| Upon inspection it was noted the annular space was on vacuum. Injection operations shall cease immediately and a mechanical integrity test shall be performed. | | Upon inspection it was noted the annular space was on vacuum. Injection operations shall cease immediately and a mechanical integrity test shall be performed. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1223492827 | | 1223492827 | ||
| 2005-11-04 | | 2005-11-04 | ||
− | | | + | | |
| There were no violations at the time of inspection. | | There were no violations at the time of inspection. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1285061708 | | 1285061708 | ||
| 2013-04-12 | | 2013-04-12 | ||
− | | | + | | |
| Inspected the containment dike, tanks, pump house, unloading pad, injection pressure and annulus pressure. Identification on wellhead. Dike was free of water. Ohio Oil Gathering truck on site to haul oil from the 100 barrel steel tank. | | Inspected the containment dike, tanks, pump house, unloading pad, injection pressure and annulus pressure. Identification on wellhead. Dike was free of water. Ohio Oil Gathering truck on site to haul oil from the 100 barrel steel tank. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1317774207 | ||
+ | | 2010-11-19 | ||
+ | | | ||
+ | | Dike has been sealed. Oil barrel has been cleaned up. Injection fittings have been re-plumbed to allow easier access. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 1319266937 | | 1319266937 | ||
| 2007-09-12 | | 2007-09-12 | ||
− | | | + | | |
| There were no violations at the time of inspection. | | There were no violations at the time of inspection. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1333565423 | | 1333565423 | ||
| 2012-02-17 | | 2012-02-17 | ||
− | | | + | | |
| Identification is faded. I called Bob Adams and told him to remark the identification. | | Identification is faded. I called Bob Adams and told him to remark the identification. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1345728188 | | 1345728188 | ||
| 2012-08-23 | | 2012-08-23 | ||
− | | | + | | |
| Less than one gallon of fresh water was used to fill the annular space. 345 pounds were placed on the annular space and less than the allowable 5% loss was observed over the fifteen minute testing period. Less than five pounds total were lost. | | Less than one gallon of fresh water was used to fill the annular space. 345 pounds were placed on the annular space and less than the allowable 5% loss was observed over the fifteen minute testing period. Less than five pounds total were lost. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1345829422 | | 1345829422 | ||
| 2012-08-24 | | 2012-08-24 | ||
− | | | + | | |
| The company had just re-plumbed the well. I stopped in to check the injection pressures. There were no violations at the time of inspection. | | The company had just re-plumbed the well. I stopped in to check the injection pressures. There were no violations at the time of inspection. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1352102150 | | 1352102150 | ||
| 2011-07-12 | | 2011-07-12 | ||
− | | | + | | |
| No violations | | No violations | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1370527418 | | 1370527418 | ||
| 2013-06-06 | | 2013-06-06 | ||
− | | | + | | |
+ | | No violations. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -1380435045 | ||
+ | | 2013-07-17 | ||
+ | | | ||
| No violations. | | No violations. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1402009417 | | 1402009417 | ||
| 2014-07-24 | | 2014-07-24 | ||
− | | | + | | |
| No noted violations. | | No noted violations. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | 1420576743 | ||
+ | | 2015-01-06 | ||
+ | | | ||
+ | | Inspected the unloading pad, containment dike, tanks, pump house, injection line, injection pressure and annulus pressure. Identification is faded. I called company and told them to refresh the identification lease name and API number. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1420652212 | ||
+ | | 2015-01-07 | ||
+ | | | ||
+ | | Identification is not complete. I called Bob Adams (field supervisor for company) and we discussed the violation and how to remedy it. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 1422291796 | ||
+ | | 2015-01-26 | ||
+ | | | ||
+ | | Compliance Notice 1420576743 Follow up inspection. Identification is posted. Checked brine truck unloading on pad. Inspected the unloading pad, containment dike, tanks, pump house, injection line, injection pressure and annulus pressure. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 1440203876 | | 1440203876 | ||
| 2013-01-17 | | 2013-01-17 | ||
− | | | + | | |
| The well head pressures were tested while the pump was running. The pressure on the injection tubing was 240 psi and the annular space was on a vacuum. The owner shall cease all injection operations immediately until the it is determined that the mechanical integrity has been reestablished. | | The well head pressures were tested while the pump was running. The pressure on the injection tubing was 240 psi and the annular space was on a vacuum. The owner shall cease all injection operations immediately until the it is determined that the mechanical integrity has been reestablished. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1468081414 | ||
+ | | 2007-02-16 | ||
+ | | | ||
+ | | There were no violations at the time of inspection. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 1553650682 | | 1553650682 | ||
| 2009-03-17 | | 2009-03-17 | ||
− | | | + | | |
| The annulus pressure could not be gauged, due to a stuck valve. | | The annulus pressure could not be gauged, due to a stuck valve. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1555745678 | ||
+ | | 2005-07-22 | ||
+ | | | ||
+ | | Witnessed the cementing of the long string. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -1610702066 | ||
+ | | 2015-05-27 | ||
+ | | | ||
+ | | Using a temporary pump inside the dike because the pump in the house is down for repairs. No noted violations. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -1713684586 | ||
+ | | 2005-01-13 | ||
+ | | | ||
+ | | There were no violations at the time of inspection. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -1.71368E+15 | ||
+ | | 2005-01-13 | ||
+ | | | ||
+ | | There were no violations at the time of inspection. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 1734299107 | | 1734299107 | ||
| 2006-05-17 | | 2006-05-17 | ||
− | | | + | | |
| No violations were found. | | No violations were found. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1747703017 | | 1747703017 | ||
| 2014-05-15 | | 2014-05-15 | ||
− | | | + | | |
| Inspected the unloading pad, containment dike, tanks, injection line, injection pump, annulus pressure and injection pressure. | | Inspected the unloading pad, containment dike, tanks, injection line, injection pump, annulus pressure and injection pressure. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1756462270 | ||
+ | | 2005-07-07 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -1831406854 | ||
+ | | 2007-04-12 | ||
+ | | | ||
+ | | There were no violations at the time of inspection. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 1840767163 | | 1840767163 | ||
| 2007-10-22 | | 2007-10-22 | ||
− | | | + | | |
| There were no violations. | | There were no violations. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 185809969 | | 185809969 | ||
| 2008-04-21 | | 2008-04-21 | ||
− | | | + | | |
| No violations were found at the time. | | No violations were found at the time. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1887374859 | | 1887374859 | ||
| 2004-05-03 | | 2004-05-03 | ||
− | | | + | | |
| No violations at the time of inspection. | | No violations at the time of inspection. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1906886227 | | 1906886227 | ||
| 2006-08-14 | | 2006-08-14 | ||
− | | | + | | |
| There were no violations. | | There were no violations. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1936987605 | | 1936987605 | ||
| 2005-07-21 | | 2005-07-21 | ||
− | | | + | | |
| Running 4-1/2 inch casing into the well. | | Running 4-1/2 inch casing into the well. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 1961170410 | | 1961170410 | ||
| 2004-03-09 | | 2004-03-09 | ||
− | | | + | | |
| No violations at the time of inspection. | | No violations at the time of inspection. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -1965557682 | ||
+ | | 2011-03-25 | ||
+ | | | ||
+ | | Witnessed company monthly mini test. Tested annulus to 520 psi for 15 minutes. Pressure dropped to 505 in 15 minutes. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -1974093962 | ||
+ | | 2006-12-18 | ||
+ | | | ||
+ | | There were no violations at the time of inspection. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 2002938105 | | 2002938105 | ||
| 2011-11-07 | | 2011-11-07 | ||
− | | | + | | |
| Dike free of water. Id faded. | | Dike free of water. Id faded. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 2009122212 | | 2009122212 | ||
| 2005-07-20 | | 2005-07-20 | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 2086199067 | | 2086199067 | ||
| 2013-10-15 | | 2013-10-15 | ||
− | | | + | | |
| Inspected the unloading pad, containment dike, tanks, annulus pressure, and injection pressure. Containment dike is free of water. Collected a brine sample from a valve on the injection tubing between the filter housing and the well. | | Inspected the unloading pad, containment dike, tanks, annulus pressure, and injection pressure. Containment dike is free of water. Collected a brine sample from a valve on the injection tubing between the filter housing and the well. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -2090569248 | ||
+ | | 2013-12-02 | ||
+ | | | ||
+ | | No violations noted at facility. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -2117748693 | ||
+ | | 2004-02-05 | ||
+ | | | ||
+ | | Pressures were measured, while the pump was on. No violations at the time of inspection. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -26309294 | ||
+ | | 2012-04-19 | ||
+ | | | ||
+ | | Identification faded. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -288561532 | ||
+ | | 2014-02-28 | ||
+ | | | ||
+ | | No noted violations. It looks like there could be a small leak on the 2 ball valve developing. And the identification is beginning to fade. I notified field supervisor of potential issue. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -307779600 | ||
+ | | 2008-12-03 | ||
+ | | | ||
+ | | No violations were found. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -320252923 | ||
+ | | 2008-02-25 | ||
+ | | | ||
+ | | No violations were found at the time of inspection. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -326552695 | ||
+ | | 2010-07-14 | ||
+ | | | ||
+ | | Dike is free of water, and oil has been cleaned up. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -340581060 | ||
+ | | 2012-06-25 | ||
+ | | | ||
+ | | No violations. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 371610610 | | 371610610 | ||
| 2009-06-08 | | 2009-06-08 | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -382985498 | ||
+ | | 2011-03-07 | ||
+ | | | ||
+ | | Annulus had slight vacuum then zero. Injection 1/4 needle valve is not opening well and needs to be replaced. Tan colored oil in dike around pump house and wellhead, 3/4 deep in dike. Accompanied by Meigs Inspector Josh Garland. I called Bob Adams and left message Re: annulus needs tested and replace 1/4 valve. Dike has oil in it from the pump house that must be cleaned up. I stopped by American Natural Gas office and told Sue about the violations and what needs to be done to correct them. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 40540500 | | 40540500 | ||
| 2014-06-05 | | 2014-06-05 | ||
− | | | + | | |
| No noted violations. | | No noted violations. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -428472103 | ||
+ | | 2010-09-27 | ||
+ | | | ||
+ | | Cracks in dike need to be filled. Dike must be liquid tight. Oil barrel is over flowing inside dike. The injection test valve is 8 feet off the dike floor. The test valve needs to be lower and located on the well side of the check valve. Ideal location for test tee would be directly above the valve on the tubing. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -441215572 | ||
+ | | 2004-07-20 | ||
+ | | | ||
+ | | Unable to measure annular pressure. The needle valve was corroded shut. Notified operator. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 443699882 | | 443699882 | ||
| 2006-03-30 | | 2006-03-30 | ||
− | | | + | | |
| Pressures were measured while the pump was off. | | Pressures were measured while the pump was off. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -447861061 | ||
+ | | 2005-08-11 | ||
+ | | | ||
+ | | Preformed mechanical integrity test. The well passed the test with a 4% loss in pressure. | ||
+ | |||
+ | Start time: 11:26 Start pressure: 705 psi. Finish time: 11:41 Finish pressure: 676 psi. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -482224792 | ||
+ | | 2005-06-23 | ||
+ | | | ||
+ | | No one at the service rig. It appears the pipe is being tested. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -496087136 | ||
+ | | 2003-04-09 | ||
+ | | | ||
+ | | Met with Frank Herald(owner) on site to explain what is needed and required of Herald Oil to comply with this NOV. Will extend NOV until 5/9/03. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 513328171 | | 513328171 | ||
| 2008-09-17 | | 2008-09-17 | ||
− | | | + | | |
| There were no violations at the time of inspection. | | There were no violations at the time of inspection. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -519944651 | ||
+ | | 2011-03-08 | ||
+ | | | ||
+ | | Cleaning up oil in dike. 80 % has been removed. Clean up is on going. Scheduling a annulus test. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -568594611 | ||
+ | | 2009-08-18 | ||
+ | | | ||
+ | | Has identification. Dike has oil and water in it. Dike needs cleaned up. Concrete dike has cracks that need patched. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -608223106 | ||
+ | | 2004-08-17 | ||
+ | | | ||
+ | | The annular pressure needs reduced. Spoke with the operator regarding this matter. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | 638762240 | ||
+ | | 2015-03-12 | ||
+ | | | ||
+ | | No noted violations. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -645732800 | ||
+ | | 2008-06-12 | ||
+ | | | ||
+ | | No violations were found. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -650989428 | ||
+ | | 2004-06-23 | ||
+ | | | ||
+ | | No violations at the time of inspection. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 703919485 | | 703919485 | ||
| 2010-03-18 | | 2010-03-18 | ||
− | | | + | | |
| Good identification. Dike has been cleaned up. | | Good identification. Dike has been cleaned up. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -73847225 | ||
+ | | 2009-11-24 | ||
+ | | | ||
+ | | Zero pressure on annulus. Need to do mechanical integrity test on annulus. 2 valve on annulus needs to be replaced. Needle valve on injection needs to be replaced. Concrete dike has cracks that need to be patched. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -748286452 | ||
+ | | 2003-03-05 | ||
+ | | | ||
+ | | An inspection of the site revealed that the brine trucks are not using unloading pad properly, trucks not on pad, this is violation of construction requirements. Wrong Permit # on ID at tanks, oily sand indike around tanks, oil and brine under plastic liner in dike. UNLOAD BRINE TRUCKS ON UNLOADING PAD PROPERLY OR BUILD PAD LARGE ENOUGH TOO. CORRECT PERMIT # ON ID STICKERS, CLEAN UP AND REMOVE ALL CONTAMINATED SOILS IN AND UNDER PLASTIC LINER IN DIKE. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -760500646 | ||
+ | | 2005-07-12 | ||
+ | | | ||
+ | | Plugged back well. | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |- | ||
+ | | -792190530 | ||
+ | | 2006-07-11 | ||
+ | | | ||
+ | | There were no violations at the time of inspection. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 800256612 | | 800256612 | ||
| 2004-04-08 | | 2004-04-08 | ||
− | | | + | | |
| No violations at the time of inspection. | | No violations at the time of inspection. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -851042783 | ||
+ | | 2013-12-19 | ||
+ | | | ||
+ | | Inspected the containment dike, tanks, injection pump, injection line, unloading pad, injection pressure, and annulus pressure. A 4' area around a new filter housing had a skim of oil residue in the dike. I asked the well tender about this and was told that the oil is from spillage during filter changes. I suggested installing a tee with valve and a line to the sump for draining the filter housing prior to filter changes. Instead of draining the filter housing into the dike. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| 869079438 | | 869079438 | ||
| 2003-03-05 | | 2003-03-05 | ||
− | | | + | | |
| FOLLOW UP TO NOV # -748286452 An inspection of the site revealed that the brine trucks are not using unloading pad properly, trucks not on pad, this is violation of construction requirements. Wrong Permit # on ID at tanks, oily sand in dike around tanks, oil and brine under plastic li | | FOLLOW UP TO NOV # -748286452 An inspection of the site revealed that the brine trucks are not using unloading pad properly, trucks not on pad, this is violation of construction requirements. Wrong Permit # on ID at tanks, oily sand in dike around tanks, oil and brine under plastic li | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
− | | | + | | -909771906 |
− | | | + | | 2006-02-22 |
− | | | + | | |
− | | | + | | No violations were found at the time of inspection. |
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 933651915 | | 933651915 | ||
| 2007-06-06 | | 2007-06-06 | ||
− | | | + | | |
| No violations were found at the time. | | No violations were found at the time. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 96680467 | | 96680467 | ||
| 2010-11-24 | | 2010-11-24 | ||
− | | | + | | |
| Dike is free of fluids. | | Dike is free of fluids. | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| 970248812 | | 970248812 | ||
| 2009-12-15 | | 2009-12-15 | ||
− | | | + | | |
− | | Test annulus at 990 psi for 15 minutes. At 5 minutes 985psi, At 15 minutes 980psi. A new 2 | + | | Test annulus at 990 psi for 15 minutes. At 5 minutes 985psi, At 15 minutes 980psi. A new 2 ballvalve and a new 1/4 needle valve has been installed. Has id at well. They are pressure washing the dike and preparing for sealing the cracks. Released pressure on annulus down to 90psi. Injection at 180psi |
− | | | + | | |
− | | | + | | |
− | | | + | | |
+ | |- | ||
+ | |- | ||
+ | | -970616252 | ||
+ | | 2012-12-11 | ||
+ | | | ||
+ | | Inspected injection tubing pressure, annulus pressure. Inspected dike, tanks and unloading pad. Took brine sample from injection line in pump house. Transported brine sample to Jackson office for shipment to lab. An empty 4200 gallon plastic tank was seen inside the dike. | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
| PL10659 | | PL10659 | ||
− | | | + | | |
− | | | + | | |
| Preliminary Restoration done information from Data Point | | Preliminary Restoration done information from Data Point | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| UIC1501 | | UIC1501 | ||
| 1994-06-17 | | 1994-06-17 | ||
− | | | + | | |
| 1501: 9-9-05 (A) (9) REMOVE FLUID - DIKE | | 1501: 9-9-05 (A) (9) REMOVE FLUID - DIKE | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| UIC1579 | | UIC1579 | ||
| 1995-05-18 | | 1995-05-18 | ||
− | | | + | | |
| 1501: 9-3-07 (E) QUARTERLY REPORTS | | 1501: 9-3-07 (E) QUARTERLY REPORTS | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| UIC1719 | | UIC1719 | ||
| 1998-05-20 | | 1998-05-20 | ||
− | | | + | | |
| 1501:9-3-07 (E) (F) QUARTERLY REPORTS | | 1501:9-3-07 (E) (F) QUARTERLY REPORTS | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|- | |- | ||
| UIC430 | | UIC430 | ||
| 1987-12-08 | | 1987-12-08 | ||
− | | | + | | |
| 1501:9-3-7 (E)(F) | | 1501:9-3-7 (E)(F) | ||
− | | | + | | |
− | | | + | | |
− | | | + | | |
|- | |- | ||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Ohio Department of Natural Resources RBDMS | ||
+ | | publisher = [http://oilandgas.ohiodnr.gov/] | ||
+ | | date = 2015-06-19 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection | ||
+ | | accessdate = 2015-06-20 }}</ref> | ||
+ | == References == | ||
+ | {{reflist}} | ||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
[[Category:Wells]] | [[Category:Wells]] |
Well ID: 34-105-23319 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.06257255,"lon":-82.05656588,"icon":""}]} |
County: Meigs | |
Municipality: | |
Operator Name: AMERICAN NATURAL GAS INC | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1984-12-01 | |
Unconventional: No | |
Configuration: Vertical | |
Well Status: Active Injection | |
Violations: 0 | |
Latitude: 39.06257255 | |
Longitude: -82.05656588 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
1988-0 | 5871.0 | 416.0 | ||||
2000-0 | 0.0 | 463.0 | ||||
2001-0 | 0.0 | 305.0 | ||||
2002-0 | 0.0 | 58.0 | ||||
2003-0 | 0.0 | 131.0 | ||||
2004-0 | 0.0 | 19.0 | ||||
2005-0 | 0.0 | 63.0 | ||||
2006-0 | 0.0 | 0.0 |
For data sources see[1]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION COMMENT |
---|---|---|---|---|---|---|
-101835701 | 2014-11-19 | No noted violations at facility. | Compliance Notice | |||
-101835701 | 2014-11-19 | No noted violations at facility. | Phone Call | |||
-101835701 | 2014-11-19 | No noted violations at facility. | Phone Call | |||
-101835701 | 2014-11-19 | No noted violations at facility. | Phone Call | |||
-101835701 | 2014-11-19 | No noted violations at facility. | Field Visit or Inspection | |||
-101835701 | 2014-11-19 | No noted violations at facility. | Field Visit or Inspection | |||
-101835701 | 2014-11-19 | No noted violations at facility. | Field Visit or Inspection | |||
-101835701 | 2014-11-19 | No noted violations at facility. | Compliance Notice | |||
-101835701 | 2014-11-19 | No noted violations at facility. | Field Visit or Inspection | |||
-101835701 | 2014-11-19 | No noted violations at facility. | Field Visit or Inspection | |||
-101835701 | 2014-11-19 | No noted violations at facility. | ||||
-101835701 | 2014-11-19 | No noted violations at facility. | Compliance Notice | |||
-101835701 | 2014-11-19 | No noted violations at facility. | Compliance Notice | |||
-101835701 | 2014-11-19 | No noted violations at facility. | ||||
-101835701 | 2014-11-19 | No noted violations at facility. | ||||
-101835701 | 2014-11-19 | No noted violations at facility. | ||||
-101835701 | 2014-11-19 | No noted violations at facility. | ||||
-1019317996 | 2005-05-06 | Pump was off, while the readings were taken. | ||||
-1034071380 | 2005-08-04 | |||||
-104043520 | 2004-10-08 | There were no violations at the time of inspection. | ||||
1070648922 | 2003-12-04 | No violations at the time of inspection. | ||||
1127139298 | 2005-08-10 | Waited for cement bond log to be completed. Then, witnessed the packer installation. | ||||
-1149894788 | 2006-10-17 | No violations. Accompanied by Jon Scott. | ||||
-1158475857 | 2007-07-17 | There were no violations at the time. | ||||
1167241693 | 2012-08-22 | Upon inspection it was noted the annular space was on vacuum. Injection operations shall cease immediately and a mechanical integrity test shall be performed. | ||||
1223492827 | 2005-11-04 | There were no violations at the time of inspection. | ||||
1285061708 | 2013-04-12 | Inspected the containment dike, tanks, pump house, unloading pad, injection pressure and annulus pressure. Identification on wellhead. Dike was free of water. Ohio Oil Gathering truck on site to haul oil from the 100 barrel steel tank. | ||||
-1317774207 | 2010-11-19 | Dike has been sealed. Oil barrel has been cleaned up. Injection fittings have been re-plumbed to allow easier access. | ||||
1319266937 | 2007-09-12 | There were no violations at the time of inspection. | ||||
1333565423 | 2012-02-17 | Identification is faded. I called Bob Adams and told him to remark the identification. | ||||
1345728188 | 2012-08-23 | Less than one gallon of fresh water was used to fill the annular space. 345 pounds were placed on the annular space and less than the allowable 5% loss was observed over the fifteen minute testing period. Less than five pounds total were lost. | ||||
1345829422 | 2012-08-24 | The company had just re-plumbed the well. I stopped in to check the injection pressures. There were no violations at the time of inspection. | ||||
1352102150 | 2011-07-12 | No violations | ||||
1370527418 | 2013-06-06 | No violations. | ||||
-1380435045 | 2013-07-17 | No violations. | ||||
1402009417 | 2014-07-24 | No noted violations. | ||||
1420576743 | 2015-01-06 | Inspected the unloading pad, containment dike, tanks, pump house, injection line, injection pressure and annulus pressure. Identification is faded. I called company and told them to refresh the identification lease name and API number. | ||||
1420652212 | 2015-01-07 | Identification is not complete. I called Bob Adams (field supervisor for company) and we discussed the violation and how to remedy it. | ||||
1422291796 | 2015-01-26 | Compliance Notice 1420576743 Follow up inspection. Identification is posted. Checked brine truck unloading on pad. Inspected the unloading pad, containment dike, tanks, pump house, injection line, injection pressure and annulus pressure. | ||||
1440203876 | 2013-01-17 | The well head pressures were tested while the pump was running. The pressure on the injection tubing was 240 psi and the annular space was on a vacuum. The owner shall cease all injection operations immediately until the it is determined that the mechanical integrity has been reestablished. | ||||
-1468081414 | 2007-02-16 | There were no violations at the time of inspection. | ||||
1553650682 | 2009-03-17 | The annulus pressure could not be gauged, due to a stuck valve. | ||||
-1555745678 | 2005-07-22 | Witnessed the cementing of the long string. | ||||
-1610702066 | 2015-05-27 | Using a temporary pump inside the dike because the pump in the house is down for repairs. No noted violations. | ||||
-1713684586 | 2005-01-13 | There were no violations at the time of inspection. | ||||
-1.71368E+15 | 2005-01-13 | There were no violations at the time of inspection. | ||||
1734299107 | 2006-05-17 | No violations were found. | ||||
1747703017 | 2014-05-15 | Inspected the unloading pad, containment dike, tanks, injection line, injection pump, annulus pressure and injection pressure. | ||||
-1756462270 | 2005-07-07 | |||||
-1831406854 | 2007-04-12 | There were no violations at the time of inspection. | ||||
1840767163 | 2007-10-22 | There were no violations. | ||||
185809969 | 2008-04-21 | No violations were found at the time. | ||||
1887374859 | 2004-05-03 | No violations at the time of inspection. | ||||
1906886227 | 2006-08-14 | There were no violations. | ||||
1936987605 | 2005-07-21 | Running 4-1/2 inch casing into the well. | ||||
1961170410 | 2004-03-09 | No violations at the time of inspection. | ||||
-1965557682 | 2011-03-25 | Witnessed company monthly mini test. Tested annulus to 520 psi for 15 minutes. Pressure dropped to 505 in 15 minutes. | ||||
-1974093962 | 2006-12-18 | There were no violations at the time of inspection. | ||||
2002938105 | 2011-11-07 | Dike free of water. Id faded. | ||||
2009122212 | 2005-07-20 | |||||
2086199067 | 2013-10-15 | Inspected the unloading pad, containment dike, tanks, annulus pressure, and injection pressure. Containment dike is free of water. Collected a brine sample from a valve on the injection tubing between the filter housing and the well. | ||||
-2090569248 | 2013-12-02 | No violations noted at facility. | ||||
-2117748693 | 2004-02-05 | Pressures were measured, while the pump was on. No violations at the time of inspection. | ||||
-26309294 | 2012-04-19 | Identification faded. | ||||
-288561532 | 2014-02-28 | No noted violations. It looks like there could be a small leak on the 2 ball valve developing. And the identification is beginning to fade. I notified field supervisor of potential issue. | ||||
-307779600 | 2008-12-03 | No violations were found. | ||||
-320252923 | 2008-02-25 | No violations were found at the time of inspection. | ||||
-326552695 | 2010-07-14 | Dike is free of water, and oil has been cleaned up. | ||||
-340581060 | 2012-06-25 | No violations. | ||||
371610610 | 2009-06-08 | |||||
-382985498 | 2011-03-07 | Annulus had slight vacuum then zero. Injection 1/4 needle valve is not opening well and needs to be replaced. Tan colored oil in dike around pump house and wellhead, 3/4 deep in dike. Accompanied by Meigs Inspector Josh Garland. I called Bob Adams and left message Re: annulus needs tested and replace 1/4 valve. Dike has oil in it from the pump house that must be cleaned up. I stopped by American Natural Gas office and told Sue about the violations and what needs to be done to correct them. | ||||
40540500 | 2014-06-05 | No noted violations. | ||||
-428472103 | 2010-09-27 | Cracks in dike need to be filled. Dike must be liquid tight. Oil barrel is over flowing inside dike. The injection test valve is 8 feet off the dike floor. The test valve needs to be lower and located on the well side of the check valve. Ideal location for test tee would be directly above the valve on the tubing. | ||||
-441215572 | 2004-07-20 | Unable to measure annular pressure. The needle valve was corroded shut. Notified operator. | ||||
443699882 | 2006-03-30 | Pressures were measured while the pump was off. | ||||
-447861061 | 2005-08-11 | Preformed mechanical integrity test. The well passed the test with a 4% loss in pressure.
Start time: 11:26 Start pressure: 705 psi. Finish time: 11:41 Finish pressure: 676 psi. |
||||
-482224792 | 2005-06-23 | No one at the service rig. It appears the pipe is being tested. | ||||
-496087136 | 2003-04-09 | Met with Frank Herald(owner) on site to explain what is needed and required of Herald Oil to comply with this NOV. Will extend NOV until 5/9/03. | ||||
513328171 | 2008-09-17 | There were no violations at the time of inspection. | ||||
-519944651 | 2011-03-08 | Cleaning up oil in dike. 80 % has been removed. Clean up is on going. Scheduling a annulus test. | ||||
-568594611 | 2009-08-18 | Has identification. Dike has oil and water in it. Dike needs cleaned up. Concrete dike has cracks that need patched. | ||||
-608223106 | 2004-08-17 | The annular pressure needs reduced. Spoke with the operator regarding this matter. | ||||
638762240 | 2015-03-12 | No noted violations. | ||||
-645732800 | 2008-06-12 | No violations were found. | ||||
-650989428 | 2004-06-23 | No violations at the time of inspection. | ||||
703919485 | 2010-03-18 | Good identification. Dike has been cleaned up. | ||||
-73847225 | 2009-11-24 | Zero pressure on annulus. Need to do mechanical integrity test on annulus. 2 valve on annulus needs to be replaced. Needle valve on injection needs to be replaced. Concrete dike has cracks that need to be patched. | ||||
-748286452 | 2003-03-05 | An inspection of the site revealed that the brine trucks are not using unloading pad properly, trucks not on pad, this is violation of construction requirements. Wrong Permit # on ID at tanks, oily sand indike around tanks, oil and brine under plastic liner in dike. UNLOAD BRINE TRUCKS ON UNLOADING PAD PROPERLY OR BUILD PAD LARGE ENOUGH TOO. CORRECT PERMIT # ON ID STICKERS, CLEAN UP AND REMOVE ALL CONTAMINATED SOILS IN AND UNDER PLASTIC LINER IN DIKE. | ||||
-760500646 | 2005-07-12 | Plugged back well. | ||||
-792190530 | 2006-07-11 | There were no violations at the time of inspection. | ||||
800256612 | 2004-04-08 | No violations at the time of inspection. | ||||
-851042783 | 2013-12-19 | Inspected the containment dike, tanks, injection pump, injection line, unloading pad, injection pressure, and annulus pressure. A 4' area around a new filter housing had a skim of oil residue in the dike. I asked the well tender about this and was told that the oil is from spillage during filter changes. I suggested installing a tee with valve and a line to the sump for draining the filter housing prior to filter changes. Instead of draining the filter housing into the dike. | ||||
869079438 | 2003-03-05 | FOLLOW UP TO NOV # -748286452 An inspection of the site revealed that the brine trucks are not using unloading pad properly, trucks not on pad, this is violation of construction requirements. Wrong Permit # on ID at tanks, oily sand in dike around tanks, oil and brine under plastic li | ||||
-909771906 | 2006-02-22 | No violations were found at the time of inspection. | ||||
933651915 | 2007-06-06 | No violations were found at the time. | ||||
96680467 | 2010-11-24 | Dike is free of fluids. | ||||
970248812 | 2009-12-15 | Test annulus at 990 psi for 15 minutes. At 5 minutes 985psi, At 15 minutes 980psi. A new 2 ballvalve and a new 1/4 needle valve has been installed. Has id at well. They are pressure washing the dike and preparing for sealing the cracks. Released pressure on annulus down to 90psi. Injection at 180psi | ||||
-970616252 | 2012-12-11 | Inspected injection tubing pressure, annulus pressure. Inspected dike, tanks and unloading pad. Took brine sample from injection line in pump house. Transported brine sample to Jackson office for shipment to lab. An empty 4200 gallon plastic tank was seen inside the dike. | ||||
PL10659 | Preliminary Restoration done information from Data Point | |||||
UIC1501 | 1994-06-17 | 1501: 9-9-05 (A) (9) REMOVE FLUID - DIKE | ||||
UIC1579 | 1995-05-18 | 1501: 9-3-07 (E) QUARTERLY REPORTS | ||||
UIC1719 | 1998-05-20 | 1501:9-3-07 (E) (F) QUARTERLY REPORTS | ||||
UIC430 | 1987-12-08 | 1501:9-3-7 (E)(F) |
For data sources see[2]