X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-163-20318"

m
 
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-163-20318
 
| Well ID: 34-163-20318
| style="height=100%; align=center" rowspan="15" | {{#display_map: 39.3201708844, -82.4263555799 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 39.32052005, -82.4262431 | width=100% | height=100% }}  
 
|-
 
|-
| County:
+
| County: [[Vinton County, Ohio|Vinton]]
 
|-
 
|-
| Municipality:
+
| Municipality:  
 
|-
 
|-
| Operator Name:
+
| Operator Name: [[ADAMS OIL & GAS]]
 
|-
 
|-
| Well Pad ID:
+
| Well Pad ID:  
 
|-
 
|-
| Farm/Lease Name:
+
| Farm/Lease Name:  
 
|-
 
|-
| First Permit Date:
+
| First Permit Date:  
 
|-
 
|-
| Last Permit Date:
+
| Last Permit Date:  
 
|-
 
|-
 
| Spud Date: 1965-08-16
 
| Spud Date: 1965-08-16
 
|-
 
|-
| Unconventional:
+
| Unconventional: No
 
|-
 
|-
| Horizontal:
+
| Configuration: Vertical
 
|-
 
|-
| Producing: No
+
| Well Status: Active Injection
 
|-
 
|-
| Violations: 9
+
| Violations: 0
 
|-
 
|-
| Latitude: 39.3201708844
+
| Latitude: 39.32052005
 
|-
 
|-
| Longitude: -82.4263555799
+
| Longitude: -82.4262431
 
|-
 
|-
|}
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | PERIOD
 
!scope="col" | GAS QUANTITY
 
!scope="col" | GAS PRODUCTION DAYS
 
!scope="col" | CONDENSATE QUANTITY
 
!scope="col" | CONDENSATE PRODUCTION DAYS
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL PRODUCTION DAYS
 
|}
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | PERIOD
 
!scope="col" | TYPE
 
!scope="col" | QUANTITY
 
!scope="col" | UNITS
 
!scope="col" | DISPOSAL METHOD
 
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|}
 
|}
 
== Inspection Data ==
 
== Inspection Data ==
Line 64: Line 42:
 
!scope="col" | VIOLATION ID
 
!scope="col" | VIOLATION ID
 
!scope="col" | VIOLATION CODE
 
!scope="col" | VIOLATION CODE
!scope="col" | VIOLATION_COMMENT
+
!scope="col" | VIOLATION COMMENT
 
|-
 
|-
| -1058049147
+
| 1030713964
| 2012-02-07
+
| 2009-03-03
|
+
|  
| Enhanced recovery injection well is not connected to injection lines or equipment. Annulus has zero pressure. Injection tubing has zero pressure. Tank dike is full of water. Photos were taken of enhanced recovery injection well, tanks and dike.
+
| An inspection revealed that the injection side of the well will need to be equipped with  a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck. The dike is full of fluid and will need to be pumped.  The identification still shows the wrong owner. The well owner has been instructed to correct deficiencies.
|
+
|  
|
+
|  
|
+
| Compliance Notice
 
|-
 
|-
 
|-
 
|-
| -1228523624
+
| 1030713964
| 2004-05-24
+
| 2009-03-03
|
+
|  
| FOLLOW UP TO NOV # 1085405554 Reviewing records at the Vinton Co Courthouse, show the well has been assigned to Team RM, Inc.,2178 Castle Crest Dr., Worthington, Ohio
+
| An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck.  The dike is full of fluid and will need to be pumped.  The identification still shows the wrong owner.  The well owner has been instructed to correct deficiencies.
|
+
|  
| 9-5-10(J)
+
|  
|
+
| Compliance Notice
 
|-
 
|-
 
|-
 
|-
| -1271345052
+
| 1030713964
| 2013-01-15
+
| 2009-03-03
|
+
|  
| Enhanced recovery injection well is not connected to injection lines or equipment. Annulus has zero pressure. Injection tubing has zero pressure. Tank dike is full of water. Photos were taken of enhanced recovery injection well, tanks and dike. Accompanied by Andy Thomas MRI 2.
+
| An inspection revealed that the injection side of the well will need to be equipped with  a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck. The dike is full of fluid and will need to be pumped.  The identification still shows the wrong owner. The well owner has been instructed to correct deficiencies.
|
+
|  
|
+
|  
|
+
| Compliance Notice
 
|-
 
|-
 
|-
 
|-
| -1325486019
+
| 1030713964
| 2008-02-25
+
| 2009-03-03
|
+
|  
| A follow-up inspection revealed non-compliance.
+
| An inspection revealed that the injection side of the well will need to be equipped with  a 1/4 valve.  The annulus pressure was not obtained, due to a valve that was stuck.  The dike is full of fluid and will need to be pumped.  The identification still shows the wrong owner.  The well owner has been instructed to correct deficiencies.
|
+
|  
|
+
|  
|
+
| Compliance Notice
 
|-
 
|-
 
|-
 
|-
| -1350544812
+
| 1030713964
| 2009-04-07
+
| 2009-03-03
|
+
|  
| A follow-up inspection revealed that a 1/4" valve has been placed on the injection side of the well.  The valve for the annulus has been repaired and will now open.  No pressure was observed on the annulus and injection side of the wellAt the time of the inspection, the dike still contained fluid with no observed leaks.  A section along the side of this dike contains a trench and will need to be repaired.  The company has been instructed of this deficiency to include the liner that contains small tears along the top.  The identification at both the well and tank battery locations have been painted over incorrect well owner, Mountaineer Gas Transmission.  Adams Oil & Gas and ERP # will need to be added to the ID.
+
| An inspection revealed that the injection side of the well will need to be equipped with  a 1/4 valve.  The annulus pressure was not obtained, due to a valve that was stuckThe dike is full of fluid and will need to be pumped.  The identification still shows the wrong owner.  The well owner has been instructed to correct deficiencies.
|
+
|  
|
+
|  
|
+
| Compliance Notice
 
|-
 
|-
 
|-
 
|-
| -1465409721
+
| 1030713964
| 2008-09-11
+
| 2009-03-03
|
+
|  
| A follow-up inspection revealed non-compliance.  No action has been taken to resolve violations.  The injection side of the well will require a 1/4" fitting that will allow for a gauge to be installed.  The valve was opened and no vacuum or pressure was observed.  At the time of this inspection, a valve located on the annular side of the well could not be opened.  Therefore, the pressure was not obtained.  The meter connected to this well has been removed.  No identification was observed at the well and storage tanks.  A trench cut in the side of the dike will need to be repaired.  The liner contains small tears at locations along the top of the dike.
+
| An inspection revealed that the injection side of the well will need to be equipped with  a 1/4 valve.  The annulus pressure was not obtained, due to a valve that was stuck.  The dike is full of fluid and will need to be pumped.  The identification still shows the wrong owner.  The well owner has been instructed to correct deficiencies.
|
+
|  
|
+
|  
|
+
| Compliance Notice
 
|-
 
|-
 
|-
 
|-
| -1568589864
+
| 1030713964
| 2013-01-15
+
| 2009-03-03
|
+
|  
| Accompanied Inspector Jon Scott on this inspection.  No attempts have been made by company to gain compliance. Well head is disconnected from linesAnnulus and injection pressures are 0Containment dike is full of waterSpoke with the caretakers of the property, and gave them my card to give to the land owner.
+
| An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valveThe annulus pressure was not obtained, due to a valve that was stuckThe dike is full of fluid and will need to be pumpedThe identification still shows the wrong owner.  The well owner has been instructed to correct deficiencies.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
| -1719310720
+
| 1030713964
| 2009-09-01
+
| 2009-03-03
|
+
|  
| A follow-up inspection was conducted with Mr. Jeff Fry, West Region Oil & Gas Supervisor and UIC Field SupervisorIt was noted that the well status remains the same.
+
| An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck.  The dike is full of fluid and will need to be pumpedThe identification still shows the wrong owner.  The well owner has been instructed to correct deficiencies.
|
+
|  
|
+
|  
|
+
| Compliance Notice
 
|-
 
|-
 
|-
 
|-
| -1851787812
+
| 1030713964
| 2011-01-05
+
| 2009-03-03
|
+
|  
| An inspection revealed identification has now been corrected at the well.  No injection at this time.  The motor and injection lines from inside the shed have been removed.
+
| An inspection revealed that the injection side of the well will need to be equipped with  a 1/4 valveThe annulus pressure was not obtained, due to a valve that was stuck.  The dike is full of fluid and will need to be pumped.  The identification still shows the wrong owner.  The well owner has been instructed to correct deficiencies.
|
+
|  
|
+
|  
|
+
| Compliance Notice
 
|-
 
|-
 
|-
 
|-
| -2081918514
+
| 1030713964
| 2004-04-12
+
| 2009-03-03
|
+
|  
| An inspection of the well revealed well is incapable of producing, will start a I & O file on well.
+
| An inspection revealed that the injection side of the well will need to be equipped with  a 1/4 valve.  The annulus pressure was not obtained, due to a valve that was stuck.  The dike is full of fluid and will need to be pumped.  The identification still shows the wrong owner.  The well owner has been instructed to correct deficiencies.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
| -375170677
+
| 1030713964
| 2004-01-29
+
| 2009-03-03
|
+
|  
| Well is idle, unable to locate company, may need to turn over to I & O section for plugging.
+
| An inspection revealed that the injection side of the well will need to be equipped with  a 1/4 valve.  The annulus pressure was not obtained, due to a valve that was stuck.  The dike is full of fluid and will need to be pumped.  The identification still shows the wrong owner.  The well owner has been instructed to correct deficiencies.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
| -452102597
+
| 1030713964
| 2009-06-12
+
| 2009-03-03
|
+
|  
| An inspection revealed that the status remains unchanged.  No injection at this time.  The tanks are not connected to the well and valves are closed.  The pump does not contain a belt.  2" black plastic from 210 bbl tank to pump (inlet) and 2" steel from pump to well (outlet) found disconnected at well.  ID found not incomplete as, well owner name, emergency#, well name and ERP# were not observed.  6" of freshwater with aquatic life observed in dike. A 1' x 6" trench cut out along backside of dike for drainage(2) 210 bbl tanks are corroding, but unable to tell if leaking due to fluid inside dike.  The ID at tank location contains only correct owner name and emergency contact#..  The dike height is from 6' to 7'.  The liner contains approximately 5 tears along the top backside of dike.  The tears range from 6" to 2'.  Positive pressure was observed on annulus.
+
| An inspection revealed that the injection side of the well will need to be equipped with  a 1/4 valveThe annulus pressure was not obtained, due to a valve that was stuck.  The dike is full of fluid and will need to be pumped.  The identification still shows the wrong owner.  The well owner has been instructed to correct deficiencies.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
| -5293354
+
| 1030713964
| 2008-12-23
+
| 2009-03-03
|
+
|  
| A follow-up inspection revealed compliance.  Identification is displayed at the well and the storage tanks. However, the identification does not contain a lease name and Mountaineer Gas Transmission is listed as the owner.  At the time of the inspection, RBDMS showed that Adams Oil & Gas is still the owner of this well.  The previous inspection (mini-test) showed positive pressure on the annulus.  During the inspection, a ball valve could not be opened therefore, the pressure was not obtained.
+
| An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valve.  The annulus pressure was not obtained, due to a valve that was stuck. The dike is full of fluid and will need to be pumped. The identification still shows the wrong ownerThe well owner has been instructed to correct deficiencies.
|
+
|  
|
+
|  
|
+
|  
|-
 
|-
 
| -609848609
 
| 2009-12-11
 
|
 
| An inspection revealed positive pressure on the annular side of the well.  As previously noted, the well status remains the same.  The observed identification at tanks and well is not complete and the surface facility not connected for injection.
 
|
 
|
 
|
 
|-
 
|-
 
| -671344262
 
| 2013-08-12
 
|
 
| Chief's Order follow-up inspection. There has been no changes to the well or surface facility since the last inspection. Wellhead has been turned 3/4 of a turn. Injection tubing master valve and cross with two valves has been removed from the well. Annulus pressure gauge is damaged. Identification is on the ground at the well. There was no pressure on the annulus. Injection tubing is open with no valve. Containment dike is full of water. Site is over grown with vegetation. There are two steel tanks in the dike. Photos were taken.
 
|
 
|
 
|
 
|-
 
|-
 
| -825804352
 
| 2008-06-11
 
|
 
| A follow-up inspection revealed non-complianceNo action has been taken to resolve violations.
 
|
 
|
 
|
 
|-
 
|-
 
| -861525785
 
| 2008-11-12
 
|
 
| A mini-test revealed 3 psi loss after 15 minutes.  The well passed the required test.
 
|
 
|
 
|
 
|-
 
|-
 
| -92966440
 
| 2012-02-07
 
|
 
| Accompanied Inspector Jon Scott on an inspection of this well and tank battery.  Updated photos were taken.
 
|
 
|
 
|
 
 
|-
 
|-
 
|-
 
|-
 
| 1030713964
 
| 1030713964
 
| 2009-03-03
 
| 2009-03-03
|
+
|  
| An inspection revealed that the injection side of the well will need to be equipped with  a 1/4" valve.  The annulus pressure was not obtained, due to a valve that was stuck.  The dike is full of fluid and will need to be pumped.  The identification still shows the wrong owner.  The well owner has been instructed to correct deficiencies.
+
| An inspection revealed that the injection side of the well will need to be equipped with  a 1/4 valve.  The annulus pressure was not obtained, due to a valve that was stuck.  The dike is full of fluid and will need to be pumped.  The identification still shows the wrong owner.  The well owner has been instructed to correct deficiencies.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1045495259
 
| 1045495259
 
| 2013-09-12
 
| 2013-09-12
|
+
|  
 
| I accompanied Jon Scott on the inspection of this well. There is a Chiefs order that has not be satisfied. The well is idle and in disrepair. The dike has 18'' of water in it. There was no pressure on the annulus.
 
| I accompanied Jon Scott on the inspection of this well. There is a Chiefs order that has not be satisfied. The well is idle and in disrepair. The dike has 18'' of water in it. There was no pressure on the annulus.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -1058049147
 +
| 2012-02-07
 +
|
 +
| Enhanced recovery injection well is not connected to injection lines or equipment. Annulus has zero pressure. Injection tubing has zero pressure. Tank dike is full of water. Photos were taken of enhanced recovery injection well, tanks and dike.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 1085405554
 
| 1085405554
 
| 2004-05-24
 
| 2004-05-24
|
+
|  
 
| Reviewing records at the Vinton Co Courthouse, show the well has been assigned to Team RM, Inc.,2178 Castle Crest Dr., Worthington, Ohio
 
| Reviewing records at the Vinton Co Courthouse, show the well has been assigned to Team RM, Inc.,2178 Castle Crest Dr., Worthington, Ohio
|
+
|  
| 9-5-10(J)
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 109853924
 
| 109853924
 
| 2014-04-07
 
| 2014-04-07
|
+
|  
 
| Compliance notice follow-up. The well consists of 2-210 barrel tanks, injection well and 3- 100 barrel tanks.  Nothing has been done to bring the well into compliance.
 
| Compliance notice follow-up. The well consists of 2-210 barrel tanks, injection well and 3- 100 barrel tanks.  Nothing has been done to bring the well into compliance.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1101136015
 
| 1101136015
 
| 2004-08-16
 
| 2004-08-16
|
+
|  
 
| Follow-up on NOV, Non-Compliance, well still idle.
 
| Follow-up on NOV, Non-Compliance, well still idle.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 115189686
 
| 115189686
 
| 2012-08-02
 
| 2012-08-02
|
+
|  
 
| No change since last inspection.  Accompanied by inspector Morgan Button.
 
| No change since last inspection.  Accompanied by inspector Morgan Button.
|
+
|  
|
+
|  
|
+
|  
|-
 
|-
 
| 1154308579
 
| 2006-07-19
 
|
 
| An inspection was conducted at the facility owned by Adams Oil & Gas on 7/19/2006.  During the inspection, it was noted that there was no pressure at the injection or annulus side of the well.  A mini test will be required.  The dike needs repaired.  The unloading pad also needs to be repaired because, it is cracking.  No identification at the wellhead or at the storage tanks.
 
|
 
| 9-5-10(F)
 
|
 
 
|-
 
|-
 
|-
 
|-
 
| 1154308579
 
| 1154308579
 
| 2006-07-19
 
| 2006-07-19
|
+
|  
 
| An inspection was conducted at the facility owned by Adams Oil & Gas on 7/19/2006.  During the inspection, it was noted that there was no pressure at the injection or annulus side of the well.  A mini test will be required.  The dike needs repaired.  The unloading pad also needs to be repaired because, it is cracking.  No identification at the wellhead or at the storage tanks.
 
| An inspection was conducted at the facility owned by Adams Oil & Gas on 7/19/2006.  During the inspection, it was noted that there was no pressure at the injection or annulus side of the well.  A mini test will be required.  The dike needs repaired.  The unloading pad also needs to be repaired because, it is cracking.  No identification at the wellhead or at the storage tanks.
|
+
|  
| NONE(H)
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1175752455
 
| 1175752455
 
| 2006-09-13
 
| 2006-09-13
|
+
|  
 
| A follow-up inspection was conducted on 9/13/2006.  During the inspection, it was noted that the previously noted violations have not been resolved.  The company was contacted by telephone on 9/13/2006 and informed that the violations still exist.
 
| A follow-up inspection was conducted on 9/13/2006.  During the inspection, it was noted that the previously noted violations have not been resolved.  The company was contacted by telephone on 9/13/2006 and informed that the violations still exist.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1184016292
 
| 1184016292
 
| 2007-07-05
 
| 2007-07-05
|
+
|  
 
| A follow-up inspection revealed non-compliance.  No action has been taken to resolve the violations.  Mr. Jamie Adams states that the well ownership issue has not been resolved.  Also stating that they have not been working around the Vinton County area because of this issue.
 
| A follow-up inspection revealed non-compliance.  No action has been taken to resolve the violations.  Mr. Jamie Adams states that the well ownership issue has not been resolved.  Also stating that they have not been working around the Vinton County area because of this issue.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1213795798
 
| 1213795798
 
| 2008-06-11
 
| 2008-06-11
|
+
|  
 
| An inspection revealed that Adams Oil & Gas has failed to comply with previously noted violations.  Positive pressure is still needed on the annulus side of the well.  A mini-test has not been performed and will be required.  The unloading pad needs repaired, due to the concrete that is cracking.  No identification was observed at the well and storage tanks.  A new NOV will be reissued to the company.
 
| An inspection revealed that Adams Oil & Gas has failed to comply with previously noted violations.  Positive pressure is still needed on the annulus side of the well.  A mini-test has not been performed and will be required.  The unloading pad needs repaired, due to the concrete that is cracking.  No identification was observed at the well and storage tanks.  A new NOV will be reissued to the company.
|
+
|  
| 9-5-10(J )
+
|  
|
+
|  
|-
 
|-
 
| 1213795798
 
| 2008-06-11
 
|
 
| An inspection revealed that Adams Oil & Gas has failed to comply with previously noted violations.  Positive pressure is still needed on the annulus side of the well.  A mini-test has not been performed and will be required.  The unloading pad needs repaired, due to the concrete that is cracking.  No identification was observed at the well and storage tanks.  A new NOV will be reissued to the company.
 
|
 
| NONE(H)
 
|
 
 
|-
 
|-
 
|-
 
|-
 
| 1218503252
 
| 1218503252
 
| 2008-07-29
 
| 2008-07-29
|
+
|  
 
| A follow-up inspection revealed non-compliance.  No action has been taken to resolve violations.  Request Chiefs Order.
 
| A follow-up inspection revealed non-compliance.  No action has been taken to resolve violations.  Request Chiefs Order.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -1228523624
 +
| 2004-05-24
 +
|
 +
| FOLLOW UP TO NOV #  1085405554  Reviewing records at the Vinton Co Courthouse, show the well has been assigned to Team RM, Inc.,2178 Castle Crest Dr., Worthington, Ohio
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 1269i473
 
| 1269i473
 
| 2001-10-31
 
| 2001-10-31
|
+
|  
 
| Follow - up on NOV , Non - Compliance, no action to replace valve , rewrite ID at tanks , or make well capable of injecting.
 
| Follow - up on NOV , Non - Compliance, no action to replace valve , rewrite ID at tanks , or make well capable of injecting.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1269i744
 
| 1269i744
 
| 2002-02-06
 
| 2002-02-06
|
+
|  
 
| Follow-up on NOV, Non-Compliance, no action to comply with NOV or Chief's Order. Also dike standing full of fresh water at this time.
 
| Follow-up on NOV, Non-Compliance, no action to comply with NOV or Chief's Order. Also dike standing full of fresh water at this time.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1270671724
 
| 1270671724
 
| 2010-03-15
 
| 2010-03-15
|
+
|  
 
| An inspection revealed non-compliance.  The well status remains unchanged since the last inspection.  No injection at this time.  The dike contains fresh water and the fluid level will need to be addressed for capacity.  The identification sign at well and storage tank location remains incomplete.
 
| An inspection revealed non-compliance.  The well status remains unchanged since the last inspection.  No injection at this time.  The dike contains fresh water and the fluid level will need to be addressed for capacity.  The identification sign at well and storage tank location remains incomplete.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -1271345052
 +
| 2013-01-15
 +
|
 +
| Enhanced recovery injection well is not connected to injection lines or equipment. Annulus has zero pressure. Injection tubing has zero pressure. Tank dike is full of water. Photos were taken of enhanced recovery injection well, tanks and dike. Accompanied by Andy Thomas MRI 2.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 1297365034
 
| 1297365034
 
| 2011-02-10
 
| 2011-02-10
|
+
|  
 
| Upon arrival it was noted by myself and Rob Stonerock that there was no pump equipment in the building adjacent to the tank battery.  As we walked up to the tank battery, we noted several rips in the liner.  There is a pipe that sticks out toward the building that has been cut.  Containment area is filled with water up to about 1 foot from the top of the dike.  Proper identification was noted on the well head.  There are no lines going to/from well head to tank battery.
 
| Upon arrival it was noted by myself and Rob Stonerock that there was no pump equipment in the building adjacent to the tank battery.  As we walked up to the tank battery, we noted several rips in the liner.  There is a pipe that sticks out toward the building that has been cut.  Containment area is filled with water up to about 1 foot from the top of the dike.  Proper identification was noted on the well head.  There are no lines going to/from well head to tank battery.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1311805454
 
| 1311805454
 
| 2011-07-27
 
| 2011-07-27
|
+
|  
 
| CN follow up. Injection well is disconnected from injection lines. No pump on site. Tank dike is full of water. Well is not capable of injection. No change from last inspection.
 
| CN follow up. Injection well is disconnected from injection lines. No pump on site. Tank dike is full of water. Well is not capable of injection. No change from last inspection.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1323187361
 
| 1323187361
 
| 2011-12-05
 
| 2011-12-05
|
+
|  
 
| Follow up inspection for Compliance notice No. 1556115216 issued 4-6-2011. Annulus has zero pressure. Well is disconnected from injection lines. No pump equipment is on location. Dike is full of water. Identification is upside down on ground at well head. Well is not capable of injection. Photos were taken during inspection.
 
| Follow up inspection for Compliance notice No. 1556115216 issued 4-6-2011. Annulus has zero pressure. Well is disconnected from injection lines. No pump equipment is on location. Dike is full of water. Identification is upside down on ground at well head. Well is not capable of injection. Photos were taken during inspection.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -1325486019
 +
| 2008-02-25
 +
|
 +
| A follow-up inspection revealed non-compliance.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 1330533828
 
| 1330533828
 
| 2012-01-20
 
| 2012-01-20
|
+
|  
 
| Enhanced recovery injection well is not connected to injection lines or equipment. Annulus has zero pressure. Injection tubing has zero pressure. Tank dike is full of water. Photos were taken of enhanced recovery injection well, tanks and dike.
 
| Enhanced recovery injection well is not connected to injection lines or equipment. Annulus has zero pressure. Injection tubing has zero pressure. Tank dike is full of water. Photos were taken of enhanced recovery injection well, tanks and dike.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1340532399
 
| 1340532399
 
| 2011-03-31
 
| 2011-03-31
|
+
|  
 
| FOLLOW UP TO NOV #  1556115216 Injection well is disconnected from injection lines. No pump equipment on site. Tank dike is full of water. Remove water from dike. Annulus has zero pressure. Annulus must be tested to maximum injection pressure of 562 psi for 15 minutes with no more than 5% loss. Well in not capable of injection. Well must be capable of injection or plugged 1509-22 (J). Schedule mechanical integrity test with Inspector Jon Scott 740-624-4963.
 
| FOLLOW UP TO NOV #  1556115216 Injection well is disconnected from injection lines. No pump equipment on site. Tank dike is full of water. Remove water from dike. Annulus has zero pressure. Annulus must be tested to maximum injection pressure of 562 psi for 15 minutes with no more than 5% loss. Well in not capable of injection. Well must be capable of injection or plugged 1509-22 (J). Schedule mechanical integrity test with Inspector Jon Scott 740-624-4963.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -1350544812
 +
| 2009-04-07
 +
|
 +
| A follow-up inspection revealed that a 1/4 valve has been placed on the injection side of the well.  The valve for the annulus has been repaired and will now open.  No pressure was observed on the annulus and injection side of the well.  At the time of the inspection, the dike still contained fluid with no observed leaks.  A section along the side of this dike contains a trench and will need to be repaired.  The company has been instructed of this deficiency to include the liner that contains small tears along the top.  The identification at both the well and tank battery locations have been painted over incorrect well owner, Mountaineer Gas Transmission.  Adams Oil & Gas and ERP # will need to be added to the ID.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 1374086774
 
| 1374086774
 
| 2013-07-17
 
| 2013-07-17
|
+
|  
 
| Chief's Order follow-up inspection. Wellhead has been turned 3/4 of a turn. Injection tubing master valve and cross with two valves has been removed from the well. Annulus pressure gauge is damaged. Identification is on the ground at the well. There was no pressure on the annulus. Injection tubing is open with no valve. Containment dike is full of water. Site is over grown with vegetation. There are two steel tanks in the dike. Photos were taken.
 
| Chief's Order follow-up inspection. Wellhead has been turned 3/4 of a turn. Injection tubing master valve and cross with two valves has been removed from the well. Annulus pressure gauge is damaged. Identification is on the ground at the well. There was no pressure on the annulus. Injection tubing is open with no valve. Containment dike is full of water. Site is over grown with vegetation. There are two steel tanks in the dike. Photos were taken.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1384957488
 
| 1384957488
 
| 2013-11-19
 
| 2013-11-19
|
+
|  
 
| Injection tubing is open with no valve. Dike is full of water and vegetation. Annulus has zero pressure. Identification is on the ground. There has been no efforts made to equip the well for injection.
 
| Injection tubing is open with no valve. Dike is full of water and vegetation. Annulus has zero pressure. Identification is on the ground. There has been no efforts made to equip the well for injection.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| 1411580388
 +
| 2014-09-24
 +
|
 +
| Chief's Order follow up inspection. Inspected the containment dike, tanks, unloading pad, annulus pressure and injection pressure. The injection tubing is open with no master valve. Annulus has zero pressure. Site is overgrown with vegetation. Containment dike is full of water with aquatic vegetation and fish.  A skim coating of oil is on 25% of the surface area of the water. The well is not connected to injection equipment and is not capable of injection. No identification is posted on the location.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| 1426801030
 +
| 2015-03-19
 +
|
 +
| Chief's Order follow up inspection. Inspected the containment dike, tanks, unloading pad, annulus pressure and injection pressure. The injection tubing is open with no master valve. Annulus has zero pressure. Site is overgrown with vegetation.  There has been recent activity near the well, small trees have been cut down and branches are all around the well site. The containment dike is full of water with aquatic vegetation. There were no visible signs of the crude oil (in the containment dike) that was observed during the previous inspection. The well is not connected to injection equipment and is not capable of injection. No identification is posted on the location.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 145744486
 
| 145744486
 
| 2014-07-03
 
| 2014-07-03
|
+
|  
 
| Chief's Order follow up inspection. Inspected the containment dike, tanks, unloading pad, annulus pressure and injection pressure. The injection tubing is open with no master valve. Annulus has zero pressure. Site is overgrown with vegetation. Containment dike is full of water with aquatic vegetation and fish. The well is not connected to injection equipment and is not capable of injection. No identification is posted on the location.
 
| Chief's Order follow up inspection. Inspected the containment dike, tanks, unloading pad, annulus pressure and injection pressure. The injection tubing is open with no master valve. Annulus has zero pressure. Site is overgrown with vegetation. Containment dike is full of water with aquatic vegetation and fish. The well is not connected to injection equipment and is not capable of injection. No identification is posted on the location.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
| 1556115216
+
| -1465409721
| 2011-03-31
+
| 2008-09-11
|
+
|  
| Injection well is disconnected from injection lines. No pump equipment on site. Tank dike is full of water. Remove water from dike. Annulus has zero pressure. Annulus must be tested to maximum injection pressure of 562 psi for 15 minutes with no more than 5% loss. Well in not capable of injection. Well must be capable of injection or plugged 1509-22 (J). Schedule mechanical integrity test with Inspector Jon Scott 740-624-4963.
+
| A follow-up inspection revealed non-compliance. No action has been taken to resolve violations. The injection side of the well will require a 1/4 fitting that will allow for a gauge to be installed. The valve was opened and no vacuum or pressure was observed.  At the time of this inspection, a valve located on the annular side of the well could not be opened. Therefore, the pressure was not obtained. The meter connected to this well has been removed.  No identification was observed at the well and storage tanks. A trench cut in the side of the dike will need to be repaired. The liner contains small tears at locations along the top of the dike.
|
+
|  
| 9-5-10(F)
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
| 1556115216
+
| 1549013258
| 2011-03-31
+
| 2015-06-10
|
+
|  
| Injection well is disconnected from injection lines. No pump equipment on site. Tank dike is full of water. Remove water from dike. Annulus has zero pressure. Annulus must be tested to maximum injection pressure of 562 psi for 15 minutes with no more than 5% loss. Well in not capable of injection. Well must be capable of injection or plugged 1509-22 (J). Schedule mechanical integrity test with Inspector Jon Scott 740-624-4963.
+
| Chief's Order 2011-50 follow up inspection. Inspected the containment dike, tanks, unloading pad, annulus pressure and injection pressure. The injection tubing is open with no master valve. Annulus has zero pressure. Well site is overgrown with vegetation.  There has been recent activity near the well, the access road and an area near the unloading pad have been mowed recently.  The containment dike is full of water with aquatic vegetation. The well is not connected to injection equipment and is not capable of injection. No identification is posted on the location.
|
+
|  
| 9-5-10(J)
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1556115216
 
| 1556115216
 
| 2011-03-31
 
| 2011-03-31
|
+
|  
 
| Injection well is disconnected from injection lines. No pump equipment on site. Tank dike is full of water. Remove water from dike. Annulus has zero pressure. Annulus must be tested to maximum injection pressure of 562 psi for 15 minutes with no more than 5% loss. Well in not capable of injection. Well must be capable of injection or plugged 1509-22 (J). Schedule mechanical integrity test with Inspector Jon Scott 740-624-4963.
 
| Injection well is disconnected from injection lines. No pump equipment on site. Tank dike is full of water. Remove water from dike. Annulus has zero pressure. Annulus must be tested to maximum injection pressure of 562 psi for 15 minutes with no more than 5% loss. Well in not capable of injection. Well must be capable of injection or plugged 1509-22 (J). Schedule mechanical integrity test with Inspector Jon Scott 740-624-4963.
|
+
|  
| 9-9-05(A)9
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1564108278
 
| 1564108278
 
| 2002-11-25
 
| 2002-11-25
|
+
|  
 
| An inspection of the well revealed that the well is idle and incapable of injecting brine at this time, MIT test has not been done, production lines and pump not hooked up to well. No ID at the well or tanks.
 
| An inspection of the well revealed that the well is idle and incapable of injecting brine at this time, MIT test has not been done, production lines and pump not hooked up to well. No ID at the well or tanks.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 156472717
 
| 156472717
 
| 2002-11-25
 
| 2002-11-25
|
+
|  
 
| An inspection of the well revealed that the well is idle and incapable of injecting brine at this time, MIT test has not been done, production lines and pump not hooked up to well. No ID at the well or tanks.
 
| An inspection of the well revealed that the well is idle and incapable of injecting brine at this time, MIT test has not been done, production lines and pump not hooked up to well. No ID at the well or tanks.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -1568589864
 +
| 2013-01-15
 +
|
 +
| Accompanied Inspector Jon Scott on this inspection.  No attempts have been made by company to gain compliance.  Well head is disconnected from lines.  Annulus and injection pressures are 0.  Containment dike is full of water.  Spoke with the caretakers of the property, and gave them my card to give to the land owner.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| -1719310720
 +
| 2009-09-01
 +
|
 +
| A follow-up inspection was conducted with Mr. Jeff Fry, West Region Oil & Gas Supervisor and UIC Field Supervisor.  It was noted that the well status remains the same.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 1725113274
 
| 1725113274
 
| 2010-07-08
 
| 2010-07-08
|
+
|  
 
| An inspection revealed that the identification has been corrected.  The well status remains the same.  No injection at this time.
 
| An inspection revealed that the identification has been corrected.  The well status remains the same.  No injection at this time.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1832032079
 
| 1832032079
 
| 2003-05-08
 
| 2003-05-08
|
+
|  
 
| Follow-up on Chief's Order, Non-Compliance, well still idle and not injecting at this time, hung a copy of the Chief's Order on the well and storage tanks.
 
| Follow-up on Chief's Order, Non-Compliance, well still idle and not injecting at this time, hung a copy of the Chief's Order on the well and storage tanks.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1834641563
 
| 1834641563
 
| 2007-11-05
 
| 2007-11-05
|
+
|  
 
| A follow-up inspection revealed that violations have not been resolved.  No action has been taken to bring the EOR well into compliance.  The injection side of the well does not contain 1/4 inch fitting which would allow placement of gauge.  Annulus side of the well does not contain pressure.  A mini-test is required.  No identification observed.  Dike is full and needs pumped.
 
| A follow-up inspection revealed that violations have not been resolved.  No action has been taken to bring the EOR well into compliance.  The injection side of the well does not contain 1/4 inch fitting which would allow placement of gauge.  Annulus side of the well does not contain pressure.  A mini-test is required.  No identification observed.  Dike is full and needs pumped.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -1851787812
 +
| 2011-01-05
 +
|
 +
| An inspection revealed identification has now been corrected at the well.  No injection at this time.  The motor and injection lines from inside the shed have been removed.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 2051542214
 
| 2051542214
 
| 2004-11-17
 
| 2004-11-17
|
+
|  
 
| Follow-up on NOV, Non-Compliance, well still idle and incapable of producing.
 
| Follow-up on NOV, Non-Compliance, well still idle and incapable of producing.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -2081918514
 +
| 2004-04-12
 +
|
 +
| An inspection of the well revealed well is incapable of producing, will start a I & O file on well.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 2124728484
 
| 2124728484
 
| 2014-05-13
 
| 2014-05-13
|
+
|  
 
| Injection tubing is open with no master  valve. Dike is full of water and vegetation. Annulus has zero pressure. No identification. There has been no efforts made to equip the well for injection. (no injection lines or injection filters, pumps).
 
| Injection tubing is open with no master  valve. Dike is full of water and vegetation. Annulus has zero pressure. No identification. There has been no efforts made to equip the well for injection. (no injection lines or injection filters, pumps).
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -375170677
 +
| 2004-01-29
 +
|
 +
| Well is idle, unable to locate company, may need to turn over to I & O section for plugging.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 379016273
 
| 379016273
 
| 2011-03-31
 
| 2011-03-31
|
+
|  
 
| FOLLOW UP TO NOV #  1340532399 FOLLOW UP TO NOV #  1556115216 Injection well is disconnected from injection lines. No pump equipment on site. Tank dike is full of water. Remove water from dike. Annulus has zero pressure. Annulus must be tested to maximum injection pressure of 562 psi for 15 minutes with no more than 5% loss. Well in not capable of injection. Well must be capable of injection or plugged 1509-22 (J). Schedule mechanical integrity test with Inspector Jon Scott 740-624-4963.
 
| FOLLOW UP TO NOV #  1340532399 FOLLOW UP TO NOV #  1556115216 Injection well is disconnected from injection lines. No pump equipment on site. Tank dike is full of water. Remove water from dike. Annulus has zero pressure. Annulus must be tested to maximum injection pressure of 562 psi for 15 minutes with no more than 5% loss. Well in not capable of injection. Well must be capable of injection or plugged 1509-22 (J). Schedule mechanical integrity test with Inspector Jon Scott 740-624-4963.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -452102597
 +
| 2009-06-12
 +
|
 +
| An inspection revealed that the status remains unchanged.  No injection at this time.  The tanks are not connected to the well and valves are closed.  The pump does not contain a belt.  2 black plastic from 210 bbl tank to pump (inlet) and 2 steel from pump to well (outlet) found disconnected at well.  ID found not incomplete as, well owner name, emergency#, well name and ERP# were not observed.  6 of freshwater with aquatic life observed in dike.  A 1' x 6 trench cut out along backside of dike for drainage.  (2) 210 bbl tanks are corroding, but unable to tell if leaking due to fluid inside dike.  The ID at tank location contains only correct owner name and emergency contact#..  The dike height is from 6' to 7'.  The liner contains approximately 5 tears along the top backside of dike.  The tears range from 6 to 2'.  Positive pressure was observed on annulus.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| -5293354
 +
| 2008-12-23
 +
|
 +
| A follow-up inspection revealed compliance.  Identification is displayed at the well and the storage tanks.  However, the identification does not contain a lease name and Mountaineer Gas Transmission is listed as the owner.  At the time of the inspection, RBDMS showed that Adams Oil & Gas is still the owner of this well.  The previous inspection (mini-test) showed positive pressure on the annulus.  During the inspection, a ball valve could not be opened therefore, the pressure was not obtained.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 536365566
 
| 536365566
 
| 2006-07-19
 
| 2006-07-19
|
+
|  
 
| Brent Bear will issue NOV.
 
| Brent Bear will issue NOV.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 5609i102
 
| 5609i102
 
| 2001-03-22
 
| 2001-03-22
|
+
|  
| Follow - up on NOV , Non - Complaince , company has not put ID at well and or storage tanks , and put a 1/4" valve on the well for inspection.
+
| Follow - up on NOV , Non - Complaince , company has not put ID at well and or storage tanks , and put a 1/4 valve on the well for inspection.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 575326649
 
| 575326649
 
| 2003-07-28
 
| 2003-07-28
|
+
|  
 
| Follow - up on Chief's Order, well still idle and incapable of injecting brine. No action seen to comply with NOV or Chief's Order.
 
| Follow - up on Chief's Order, well still idle and incapable of injecting brine. No action seen to comply with NOV or Chief's Order.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 579330070
 
| 579330070
 
| 2013-09-12
 
| 2013-09-12
|
+
|  
 
| Injection tubing is open with no valve. Dike is full of water and vegetation. Annulus has zero pressure. Identification is on the ground. The access road to the well has been mowed. There has been no efforts made to equip the well for injection. Accompanied by Inspector Kip Thompson.
 
| Injection tubing is open with no valve. Dike is full of water and vegetation. Annulus has zero pressure. Identification is on the ground. The access road to the well has been mowed. There has been no efforts made to equip the well for injection. Accompanied by Inspector Kip Thompson.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -609848609
 +
| 2009-12-11
 +
|
 +
| An inspection revealed positive pressure on the annular side of the well.  As previously noted, the well status remains the same.  The observed identification at tanks and well is not complete and the surface facility not connected for injection.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| -671344262
 +
| 2013-08-12
 +
|
 +
| Chief's Order follow-up inspection. There has been no changes to the well or surface facility since the last inspection. Wellhead has been turned 3/4 of a turn. Injection tubing master valve and cross with two valves has been removed from the well. Annulus pressure gauge is damaged. Identification is on the ground at the well. There was no pressure on the annulus. Injection tubing is open with no valve. Containment dike is full of water. Site is over grown with vegetation. There are two steel tanks in the dike. Photos were taken.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 745432480
 
| 745432480
 
| 2011-03-31
 
| 2011-03-31
|
+
|  
 
| FOLLOW UP TO NOV #  1556115216 Injection well is disconnected from injection lines. No pump equipment on site. Tank dike is full of water. Remove water from dike. Annulus has zero pressure. Annulus must be tested to maximum injection pressure of 562 psi for 15 minutes with no more than 5% loss. Well in not capable of injection. Well must be capable of injection or plugged 1509-22 (J). Schedule mechanical integrity test with Inspector Jon Scott 740-624-4963.
 
| FOLLOW UP TO NOV #  1556115216 Injection well is disconnected from injection lines. No pump equipment on site. Tank dike is full of water. Remove water from dike. Annulus has zero pressure. Annulus must be tested to maximum injection pressure of 562 psi for 15 minutes with no more than 5% loss. Well in not capable of injection. Well must be capable of injection or plugged 1509-22 (J). Schedule mechanical integrity test with Inspector Jon Scott 740-624-4963.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -825804352
 +
| 2008-06-11
 +
|
 +
| A follow-up inspection revealed non-compliance.  No action has been taken to resolve violations.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| -861525785
 +
| 2008-11-12
 +
|
 +
| A mini-test revealed 3 psi loss after 15 minutes.  The well passed the required test.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| -92966440
 +
| 2012-02-07
 +
|
 +
| Accompanied Inspector Jon Scott on an inspection of this well and tank battery.  Updated photos were taken.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| iTOMK000112
 
| iTOMK000112
 
| 2001-02-15
 
| 2001-02-15
|
+
|  
 
| 1501:9-5-09 (A)(3) AND 1501:9-9-05 (A)(10)
 
| 1501:9-5-09 (A)(3) AND 1501:9-9-05 (A)(10)
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| UIC329
 
| UIC329
 
| 1987-03-13
 
| 1987-03-13
|
+
|  
 
| ACTION  CH.ORD  1501:9-3-07 (E)(F)  DELINQUENT QTLY RPT.
 
| ACTION  CH.ORD  1501:9-3-07 (E)(F)  DELINQUENT QTLY RPT.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| UIC705
 
| UIC705
 
| 1989-06-13
 
| 1989-06-13
|
+
|  
 
| ACTION  CH.ORD  1501:9-5-10 (E)  Delinquent Qtly Rpt.
 
| ACTION  CH.ORD  1501:9-5-10 (E)  Delinquent Qtly Rpt.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| UIC993
 
| UIC993
 
| 1990-10-12
 
| 1990-10-12
|
+
|  
 
| ACTION  CH.ORD  1501:9-3-07 E  MONTHLY VOLUMES -TL
 
| ACTION  CH.ORD  1501:9-3-07 E  MONTHLY VOLUMES -TL
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| UIC994
 
| UIC994
 
| 1990-10-12
 
| 1990-10-12
|
+
|  
 
| ACTION  CH.ORD  1501:9-3-07 F  MONITOR ANNULAR -TL
 
| ACTION  CH.ORD  1501:9-3-07 F  MONITOR ANNULAR -TL
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Ohio Department of Natural Resources RBDMS
 +
| publisher = [http://oilandgas.ohiodnr.gov/]
 +
| date = 2015-06-19
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection
 +
| accessdate = 2015-06-20 }}</ref>
 +
== References ==
 +
{{reflist}}
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 
[[Category:Wells]]
 
[[Category:Wells]]

Revision as of 02:51, 16 July 2015

Well Details

Well ID: 34-163-20318
Loading map...
County: Vinton
Municipality:
Operator Name: ADAMS OIL & GAS
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1965-08-16
Unconventional: No
Configuration: Vertical
Well Status: Active Injection
Violations: 0
Latitude: 39.32052005
Longitude: -82.4262431

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1030713964 2009-03-03 An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck. The dike is full of fluid and will need to be pumped. The identification still shows the wrong owner. The well owner has been instructed to correct deficiencies. Compliance Notice
1030713964 2009-03-03 An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck. The dike is full of fluid and will need to be pumped. The identification still shows the wrong owner. The well owner has been instructed to correct deficiencies. Compliance Notice
1030713964 2009-03-03 An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck. The dike is full of fluid and will need to be pumped. The identification still shows the wrong owner. The well owner has been instructed to correct deficiencies. Compliance Notice
1030713964 2009-03-03 An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck. The dike is full of fluid and will need to be pumped. The identification still shows the wrong owner. The well owner has been instructed to correct deficiencies. Compliance Notice
1030713964 2009-03-03 An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck. The dike is full of fluid and will need to be pumped. The identification still shows the wrong owner. The well owner has been instructed to correct deficiencies. Compliance Notice
1030713964 2009-03-03 An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck. The dike is full of fluid and will need to be pumped. The identification still shows the wrong owner. The well owner has been instructed to correct deficiencies. Compliance Notice
1030713964 2009-03-03 An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck. The dike is full of fluid and will need to be pumped. The identification still shows the wrong owner. The well owner has been instructed to correct deficiencies.
1030713964 2009-03-03 An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck. The dike is full of fluid and will need to be pumped. The identification still shows the wrong owner. The well owner has been instructed to correct deficiencies. Compliance Notice
1030713964 2009-03-03 An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck. The dike is full of fluid and will need to be pumped. The identification still shows the wrong owner. The well owner has been instructed to correct deficiencies. Compliance Notice
1030713964 2009-03-03 An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck. The dike is full of fluid and will need to be pumped. The identification still shows the wrong owner. The well owner has been instructed to correct deficiencies.
1030713964 2009-03-03 An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck. The dike is full of fluid and will need to be pumped. The identification still shows the wrong owner. The well owner has been instructed to correct deficiencies.
1030713964 2009-03-03 An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck. The dike is full of fluid and will need to be pumped. The identification still shows the wrong owner. The well owner has been instructed to correct deficiencies.
1030713964 2009-03-03 An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck. The dike is full of fluid and will need to be pumped. The identification still shows the wrong owner. The well owner has been instructed to correct deficiencies.
1030713964 2009-03-03 An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck. The dike is full of fluid and will need to be pumped. The identification still shows the wrong owner. The well owner has been instructed to correct deficiencies.
1045495259 2013-09-12 I accompanied Jon Scott on the inspection of this well. There is a Chiefs order that has not be satisfied. The well is idle and in disrepair. The dike has 18 of water in it. There was no pressure on the annulus.
-1058049147 2012-02-07 Enhanced recovery injection well is not connected to injection lines or equipment. Annulus has zero pressure. Injection tubing has zero pressure. Tank dike is full of water. Photos were taken of enhanced recovery injection well, tanks and dike.
1085405554 2004-05-24 Reviewing records at the Vinton Co Courthouse, show the well has been assigned to Team RM, Inc.,2178 Castle Crest Dr., Worthington, Ohio
109853924 2014-04-07 Compliance notice follow-up. The well consists of 2-210 barrel tanks, injection well and 3- 100 barrel tanks. Nothing has been done to bring the well into compliance.
1101136015 2004-08-16 Follow-up on NOV, Non-Compliance, well still idle.
115189686 2012-08-02 No change since last inspection. Accompanied by inspector Morgan Button.
1154308579 2006-07-19 An inspection was conducted at the facility owned by Adams Oil & Gas on 7/19/2006. During the inspection, it was noted that there was no pressure at the injection or annulus side of the well. A mini test will be required. The dike needs repaired. The unloading pad also needs to be repaired because, it is cracking. No identification at the wellhead or at the storage tanks.
1175752455 2006-09-13 A follow-up inspection was conducted on 9/13/2006. During the inspection, it was noted that the previously noted violations have not been resolved. The company was contacted by telephone on 9/13/2006 and informed that the violations still exist.
1184016292 2007-07-05 A follow-up inspection revealed non-compliance. No action has been taken to resolve the violations. Mr. Jamie Adams states that the well ownership issue has not been resolved. Also stating that they have not been working around the Vinton County area because of this issue.
1213795798 2008-06-11 An inspection revealed that Adams Oil & Gas has failed to comply with previously noted violations. Positive pressure is still needed on the annulus side of the well. A mini-test has not been performed and will be required. The unloading pad needs repaired, due to the concrete that is cracking. No identification was observed at the well and storage tanks. A new NOV will be reissued to the company.
1218503252 2008-07-29 A follow-up inspection revealed non-compliance. No action has been taken to resolve violations. Request Chiefs Order.
-1228523624 2004-05-24 FOLLOW UP TO NOV # 1085405554 Reviewing records at the Vinton Co Courthouse, show the well has been assigned to Team RM, Inc.,2178 Castle Crest Dr., Worthington, Ohio
1269i473 2001-10-31 Follow - up on NOV , Non - Compliance, no action to replace valve , rewrite ID at tanks , or make well capable of injecting.
1269i744 2002-02-06 Follow-up on NOV, Non-Compliance, no action to comply with NOV or Chief's Order. Also dike standing full of fresh water at this time.
1270671724 2010-03-15 An inspection revealed non-compliance. The well status remains unchanged since the last inspection. No injection at this time. The dike contains fresh water and the fluid level will need to be addressed for capacity. The identification sign at well and storage tank location remains incomplete.
-1271345052 2013-01-15 Enhanced recovery injection well is not connected to injection lines or equipment. Annulus has zero pressure. Injection tubing has zero pressure. Tank dike is full of water. Photos were taken of enhanced recovery injection well, tanks and dike. Accompanied by Andy Thomas MRI 2.
1297365034 2011-02-10 Upon arrival it was noted by myself and Rob Stonerock that there was no pump equipment in the building adjacent to the tank battery. As we walked up to the tank battery, we noted several rips in the liner. There is a pipe that sticks out toward the building that has been cut. Containment area is filled with water up to about 1 foot from the top of the dike. Proper identification was noted on the well head. There are no lines going to/from well head to tank battery.
1311805454 2011-07-27 CN follow up. Injection well is disconnected from injection lines. No pump on site. Tank dike is full of water. Well is not capable of injection. No change from last inspection.
1323187361 2011-12-05 Follow up inspection for Compliance notice No. 1556115216 issued 4-6-2011. Annulus has zero pressure. Well is disconnected from injection lines. No pump equipment is on location. Dike is full of water. Identification is upside down on ground at well head. Well is not capable of injection. Photos were taken during inspection.
-1325486019 2008-02-25 A follow-up inspection revealed non-compliance.
1330533828 2012-01-20 Enhanced recovery injection well is not connected to injection lines or equipment. Annulus has zero pressure. Injection tubing has zero pressure. Tank dike is full of water. Photos were taken of enhanced recovery injection well, tanks and dike.
1340532399 2011-03-31 FOLLOW UP TO NOV # 1556115216 Injection well is disconnected from injection lines. No pump equipment on site. Tank dike is full of water. Remove water from dike. Annulus has zero pressure. Annulus must be tested to maximum injection pressure of 562 psi for 15 minutes with no more than 5% loss. Well in not capable of injection. Well must be capable of injection or plugged 1509-22 (J). Schedule mechanical integrity test with Inspector Jon Scott 740-624-4963.
-1350544812 2009-04-07 A follow-up inspection revealed that a 1/4 valve has been placed on the injection side of the well. The valve for the annulus has been repaired and will now open. No pressure was observed on the annulus and injection side of the well. At the time of the inspection, the dike still contained fluid with no observed leaks. A section along the side of this dike contains a trench and will need to be repaired. The company has been instructed of this deficiency to include the liner that contains small tears along the top. The identification at both the well and tank battery locations have been painted over incorrect well owner, Mountaineer Gas Transmission. Adams Oil & Gas and ERP # will need to be added to the ID.
1374086774 2013-07-17 Chief's Order follow-up inspection. Wellhead has been turned 3/4 of a turn. Injection tubing master valve and cross with two valves has been removed from the well. Annulus pressure gauge is damaged. Identification is on the ground at the well. There was no pressure on the annulus. Injection tubing is open with no valve. Containment dike is full of water. Site is over grown with vegetation. There are two steel tanks in the dike. Photos were taken.
1384957488 2013-11-19 Injection tubing is open with no valve. Dike is full of water and vegetation. Annulus has zero pressure. Identification is on the ground. There has been no efforts made to equip the well for injection.
1411580388 2014-09-24 Chief's Order follow up inspection. Inspected the containment dike, tanks, unloading pad, annulus pressure and injection pressure. The injection tubing is open with no master valve. Annulus has zero pressure. Site is overgrown with vegetation. Containment dike is full of water with aquatic vegetation and fish. A skim coating of oil is on 25% of the surface area of the water. The well is not connected to injection equipment and is not capable of injection. No identification is posted on the location.
1426801030 2015-03-19 Chief's Order follow up inspection. Inspected the containment dike, tanks, unloading pad, annulus pressure and injection pressure. The injection tubing is open with no master valve. Annulus has zero pressure. Site is overgrown with vegetation. There has been recent activity near the well, small trees have been cut down and branches are all around the well site. The containment dike is full of water with aquatic vegetation. There were no visible signs of the crude oil (in the containment dike) that was observed during the previous inspection. The well is not connected to injection equipment and is not capable of injection. No identification is posted on the location.
145744486 2014-07-03 Chief's Order follow up inspection. Inspected the containment dike, tanks, unloading pad, annulus pressure and injection pressure. The injection tubing is open with no master valve. Annulus has zero pressure. Site is overgrown with vegetation. Containment dike is full of water with aquatic vegetation and fish. The well is not connected to injection equipment and is not capable of injection. No identification is posted on the location.
-1465409721 2008-09-11 A follow-up inspection revealed non-compliance. No action has been taken to resolve violations. The injection side of the well will require a 1/4 fitting that will allow for a gauge to be installed. The valve was opened and no vacuum or pressure was observed. At the time of this inspection, a valve located on the annular side of the well could not be opened. Therefore, the pressure was not obtained. The meter connected to this well has been removed. No identification was observed at the well and storage tanks. A trench cut in the side of the dike will need to be repaired. The liner contains small tears at locations along the top of the dike.
1549013258 2015-06-10 Chief's Order 2011-50 follow up inspection. Inspected the containment dike, tanks, unloading pad, annulus pressure and injection pressure. The injection tubing is open with no master valve. Annulus has zero pressure. Well site is overgrown with vegetation. There has been recent activity near the well, the access road and an area near the unloading pad have been mowed recently. The containment dike is full of water with aquatic vegetation. The well is not connected to injection equipment and is not capable of injection. No identification is posted on the location.
1556115216 2011-03-31 Injection well is disconnected from injection lines. No pump equipment on site. Tank dike is full of water. Remove water from dike. Annulus has zero pressure. Annulus must be tested to maximum injection pressure of 562 psi for 15 minutes with no more than 5% loss. Well in not capable of injection. Well must be capable of injection or plugged 1509-22 (J). Schedule mechanical integrity test with Inspector Jon Scott 740-624-4963.
1564108278 2002-11-25 An inspection of the well revealed that the well is idle and incapable of injecting brine at this time, MIT test has not been done, production lines and pump not hooked up to well. No ID at the well or tanks.
156472717 2002-11-25 An inspection of the well revealed that the well is idle and incapable of injecting brine at this time, MIT test has not been done, production lines and pump not hooked up to well. No ID at the well or tanks.
-1568589864 2013-01-15 Accompanied Inspector Jon Scott on this inspection. No attempts have been made by company to gain compliance. Well head is disconnected from lines. Annulus and injection pressures are 0. Containment dike is full of water. Spoke with the caretakers of the property, and gave them my card to give to the land owner.
-1719310720 2009-09-01 A follow-up inspection was conducted with Mr. Jeff Fry, West Region Oil & Gas Supervisor and UIC Field Supervisor. It was noted that the well status remains the same.
1725113274 2010-07-08 An inspection revealed that the identification has been corrected. The well status remains the same. No injection at this time.
1832032079 2003-05-08 Follow-up on Chief's Order, Non-Compliance, well still idle and not injecting at this time, hung a copy of the Chief's Order on the well and storage tanks.
1834641563 2007-11-05 A follow-up inspection revealed that violations have not been resolved. No action has been taken to bring the EOR well into compliance. The injection side of the well does not contain 1/4 inch fitting which would allow placement of gauge. Annulus side of the well does not contain pressure. A mini-test is required. No identification observed. Dike is full and needs pumped.
-1851787812 2011-01-05 An inspection revealed identification has now been corrected at the well. No injection at this time. The motor and injection lines from inside the shed have been removed.
2051542214 2004-11-17 Follow-up on NOV, Non-Compliance, well still idle and incapable of producing.
-2081918514 2004-04-12 An inspection of the well revealed well is incapable of producing, will start a I & O file on well.
2124728484 2014-05-13 Injection tubing is open with no master valve. Dike is full of water and vegetation. Annulus has zero pressure. No identification. There has been no efforts made to equip the well for injection. (no injection lines or injection filters, pumps).
-375170677 2004-01-29 Well is idle, unable to locate company, may need to turn over to I & O section for plugging.
379016273 2011-03-31 FOLLOW UP TO NOV # 1340532399 FOLLOW UP TO NOV # 1556115216 Injection well is disconnected from injection lines. No pump equipment on site. Tank dike is full of water. Remove water from dike. Annulus has zero pressure. Annulus must be tested to maximum injection pressure of 562 psi for 15 minutes with no more than 5% loss. Well in not capable of injection. Well must be capable of injection or plugged 1509-22 (J). Schedule mechanical integrity test with Inspector Jon Scott 740-624-4963.
-452102597 2009-06-12 An inspection revealed that the status remains unchanged. No injection at this time. The tanks are not connected to the well and valves are closed. The pump does not contain a belt. 2 black plastic from 210 bbl tank to pump (inlet) and 2 steel from pump to well (outlet) found disconnected at well. ID found not incomplete as, well owner name, emergency#, well name and ERP# were not observed. 6 of freshwater with aquatic life observed in dike. A 1' x 6 trench cut out along backside of dike for drainage. (2) 210 bbl tanks are corroding, but unable to tell if leaking due to fluid inside dike. The ID at tank location contains only correct owner name and emergency contact#.. The dike height is from 6' to 7'. The liner contains approximately 5 tears along the top backside of dike. The tears range from 6 to 2'. Positive pressure was observed on annulus.
-5293354 2008-12-23 A follow-up inspection revealed compliance. Identification is displayed at the well and the storage tanks. However, the identification does not contain a lease name and Mountaineer Gas Transmission is listed as the owner. At the time of the inspection, RBDMS showed that Adams Oil & Gas is still the owner of this well. The previous inspection (mini-test) showed positive pressure on the annulus. During the inspection, a ball valve could not be opened therefore, the pressure was not obtained.
536365566 2006-07-19 Brent Bear will issue NOV.
5609i102 2001-03-22 Follow - up on NOV , Non - Complaince , company has not put ID at well and or storage tanks , and put a 1/4 valve on the well for inspection.
575326649 2003-07-28 Follow - up on Chief's Order, well still idle and incapable of injecting brine. No action seen to comply with NOV or Chief's Order.
579330070 2013-09-12 Injection tubing is open with no valve. Dike is full of water and vegetation. Annulus has zero pressure. Identification is on the ground. The access road to the well has been mowed. There has been no efforts made to equip the well for injection. Accompanied by Inspector Kip Thompson.
-609848609 2009-12-11 An inspection revealed positive pressure on the annular side of the well. As previously noted, the well status remains the same. The observed identification at tanks and well is not complete and the surface facility not connected for injection.
-671344262 2013-08-12 Chief's Order follow-up inspection. There has been no changes to the well or surface facility since the last inspection. Wellhead has been turned 3/4 of a turn. Injection tubing master valve and cross with two valves has been removed from the well. Annulus pressure gauge is damaged. Identification is on the ground at the well. There was no pressure on the annulus. Injection tubing is open with no valve. Containment dike is full of water. Site is over grown with vegetation. There are two steel tanks in the dike. Photos were taken.
745432480 2011-03-31 FOLLOW UP TO NOV # 1556115216 Injection well is disconnected from injection lines. No pump equipment on site. Tank dike is full of water. Remove water from dike. Annulus has zero pressure. Annulus must be tested to maximum injection pressure of 562 psi for 15 minutes with no more than 5% loss. Well in not capable of injection. Well must be capable of injection or plugged 1509-22 (J). Schedule mechanical integrity test with Inspector Jon Scott 740-624-4963.
-825804352 2008-06-11 A follow-up inspection revealed non-compliance. No action has been taken to resolve violations.
-861525785 2008-11-12 A mini-test revealed 3 psi loss after 15 minutes. The well passed the required test.
-92966440 2012-02-07 Accompanied Inspector Jon Scott on an inspection of this well and tank battery. Updated photos were taken.
iTOMK000112 2001-02-15 1501:9-5-09 (A)(3) AND 1501:9-9-05 (A)(10)
UIC329 1987-03-13 ACTION CH.ORD 1501:9-3-07 (E)(F) DELINQUENT QTLY RPT.
UIC705 1989-06-13 ACTION CH.ORD 1501:9-5-10 (E) Delinquent Qtly Rpt.
UIC993 1990-10-12 ACTION CH.ORD 1501:9-3-07 E MONTHLY VOLUMES -TL
UIC994 1990-10-12 ACTION CH.ORD 1501:9-3-07 F MONITOR ANNULAR -TL