Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-105-23677
 
| Well ID: 34-105-23677
| style="height=100%; align=center" rowspan="15" | {{#display_map: 39.1374254816, -81.895574071 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 39.13731296, -81.89569128 | width=100% | height=100% }}  
 
|-
 
|-
| County:
+
| County: [[Meigs County, Ohio|Meigs]]
 
|-
 
|-
| Municipality:
+
| Municipality:  
 
|-
 
|-
| Operator Name:
+
| Operator Name: [[MOUNTAINEER STATE OPER LLC]]
 
|-
 
|-
| Well Pad ID:
+
| Well Pad ID:  
 
|-
 
|-
| Farm/Lease Name:
+
| Farm/Lease Name:  
 
|-
 
|-
| First Permit Date:
+
| First Permit Date:  
 
|-
 
|-
| Last Permit Date:
+
| Last Permit Date:  
 
|-
 
|-
 
| Spud Date: 2011-09-19
 
| Spud Date: 2011-09-19
 
|-
 
|-
| Unconventional:
+
| Unconventional: No
 
|-
 
|-
| Horizontal:
+
| Configuration: Vertical
 
|-
 
|-
| Producing: No
+
| Well Status: Producing
 
|-
 
|-
| Violations: 2
+
| Violations: 0
 
|-
 
|-
| Latitude: 39.1374254816
+
| Latitude: 39.13731296
 
|-
 
|-
| Longitude: -81.895574071
+
| Longitude: -81.89569128
 
|-
 
|-
 
|}
 
|}
Line 43: Line 43:
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL PRODUCTION DAYS
 
!scope="col" | OIL PRODUCTION DAYS
 +
|-
 +
| 2012-0
 +
| style="text-align:right;" | 18.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 0.0
 +
|
 +
|-
 +
|-
 +
| 2013-0
 +
| style="text-align:right;" | 0.0
 +
|
 +
|
 +
|
 +
| style="text-align:right;" | 0.0
 +
|
 +
|-
 +
|-
 +
| 2014-0
 +
| style="text-align:right;" | 0.0
 +
| style="text-align:right;" | 365.0
 +
|
 +
|
 +
| style="text-align:right;" | 0.0
 +
| style="text-align:right;" | 365.0
 +
|-
 
|}
 
|}
== Waste Data ==
+
For data sources see<ref>{{cite web
{| class="wikitable sortable" width="95%"
+
| title = Ohio Department of Natural Resources RBDMS
!scope="col" | PERIOD
+
| publisher = [http://oilandgas.ohiodnr.gov/]
!scope="col" | TYPE
+
| date = 2015-06-19
!scope="col" | QUANTITY
+
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Production
!scope="col" | UNITS
+
| accessdate = 2015-06-20 }}</ref>
!scope="col" | DISPOSAL METHOD
 
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
|}
 
 
== Inspection Data ==
 
== Inspection Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 64: Line 85:
 
!scope="col" | VIOLATION ID
 
!scope="col" | VIOLATION ID
 
!scope="col" | VIOLATION CODE
 
!scope="col" | VIOLATION CODE
!scope="col" | VIOLATION_COMMENT
+
!scope="col" | VIOLATION COMMENT
 
|-
 
|-
 
| -1244569509
 
| -1244569509
 
| 2012-12-04
 
| 2012-12-04
|
+
|  
 
| Follow up to inspection 385780457. Pits filled, no erosion, no equipment on site, vegetative cover has returned.
 
| Follow up to inspection 385780457. Pits filled, no erosion, no equipment on site, vegetative cover has returned.
|
+
|  
|
+
|  
|
+
|  
|-
 
|-
 
| -1481718940
 
| 2012-05-21
 
|
 
| Met with Tom Stone of Mountaineer State Operations to discuss erosion issues at well and remediation.
 
|
 
|
 
|
 
|-
 
|-
 
| -212780482
 
| 2012-11-13
 
|
 
| Follow up to inspection 385780457. The area has been graded, water bars have been emplaced along the road, and the area has been seeded and mulched. Grass is returning, but has covered less than 5% of the well site.
 
|
 
|
 
|
 
|-
 
|-
 
| -38659367
 
| 2011-09-26
 
|
 
| Called Tom Stone with Mountaineer State to see what depth of Berea Sandstone was.
 
|
 
|
 
|
 
|-
 
|-
 
| -465001405
 
| 2011-09-07
 
|
 
| Predrilling site review with Tom Stone of Mountaineer State Oper LLC.
 
|
 
|
 
|
 
|-
 
|-
 
| -699495920
 
| 2012-01-23
 
|
 
| Inspection revealed small oil leak on 2 inch line between mechanical separator and 100 barrel steel tank. Oil contamination radius is 1.5 feet around the 2 inch line. Took photos. Informed Tom Stone Mountaineer Field Supervisor of the leak, and instructed him to fix the leak and clean up the oil.
 
|
 
|
 
|
 
|-
 
|-
 
| -814375289
 
| 2012-10-31
 
|
 
| Follow up to inspection 385780457. The ground has been smoothed. The area has been reseeded and mulched. Vegetative cover has not yet been established. I will return on the due date to check for vegetative cove.
 
|
 
|
 
|
 
|-
 
|-
 
| -868784687
 
| 2011-09-20
 
|
 
| Surface cement job. Ran 682 feet of new 26 lb 9 5/8 inch surface casing in 690 feet of 12 1/4 borehole. 265 sacks of class A, 300 lb gel, 800 lb accelerator, 240 lb LCM, with 60% excess. Circulation established and good cement returns stayed at surface.
 
|
 
|
 
|
 
 
|-
 
|-
 
|-
 
|-
 
| 1316438664
 
| 1316438664
 
| 2011-09-19
 
| 2011-09-19
|
+
|  
 
| Drilling status check. Spudded today and 22 feet of drive pipe set in bedrock. Pit construction looks good and large enough to handle water from Injun. 30 feet of surface borehole drilled now.
 
| Drilling status check. Spudded today and 22 feet of drive pipe set in bedrock. Pit construction looks good and large enough to handle water from Injun. 30 feet of surface borehole drilled now.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1316613904
 
| 1316613904
 
| 2011-09-20
 
| 2011-09-20
|
+
|  
 
+
| Running surface casing into hole. Last two joints don
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1319463839
 
| 1319463839
 
| 2011-10-21
 
| 2011-10-21
|
+
|  
 
| Witnessed most of frac job on Gruesser well. 1978 PSI - breakdown, ~1000 PSI at 12.5 Bbl/min. When the water source was switched from pit to tanks, cuttings began to clog perfs. Pressured up to 2500 PSI and well was blown off in an attempt to clean out perfs. Attempted five times before success.
 
| Witnessed most of frac job on Gruesser well. 1978 PSI - breakdown, ~1000 PSI at 12.5 Bbl/min. When the water source was switched from pit to tanks, cuttings began to clog perfs. Pressured up to 2500 PSI and well was blown off in an attempt to clean out perfs. Attempted five times before success.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -1481718940
 +
| 2012-05-21
 +
|
 +
| Met with Tom Stone of Mountaineer State Operations to discuss erosion issues at well and remediation.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 1499898447
 
| 1499898447
 
| 2012-01-27
 
| 2012-01-27
|
+
|  
 
| No violations were noted.
 
| No violations were noted.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1518360589
 
| 1518360589
 
| 2012-09-27
 
| 2012-09-27
|
+
|  
 
| Inspection #757969285 has been voided because violation was given verbally. A written violation is being issued to the company today.
 
| Inspection #757969285 has been voided because violation was given verbally. A written violation is being issued to the company today.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|-
 
|-
 
| 1552864618
 
| 1552864618
 
| 2011-09-22
 
| 2011-09-22
|
+
|  
 
| Kerry Brown of Monroe drilling let me know the hole had bridged off when the wire log had been run.  Longstring to be delayed.
 
| Kerry Brown of Monroe drilling let me know the hole had bridged off when the wire log had been run.  Longstring to be delayed.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -212780482
 +
| 2012-11-13
 +
|
 +
| Follow up to inspection 385780457. The area has been graded, water bars have been emplaced along the road, and the area has been seeded and mulched. Grass is returning, but has covered less than 5% of the well site.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 385780457
 
| 385780457
 
| 2012-09-27
 
| 2012-09-27
|
+
|  
 
| Failure to complete the initial restoration requirements as required under division (A) of section 1509.072 of the Revised Code. An area around the wellhead and along the uphill and downhill sides of the site is void of vegetative cover. The owner or the owner's agent shall grade or terrace and plant, seed, or sod the area disturbed that is not required in production of the well where necessary to bind the soil and prevent substantial erosion and sedimentation. Failure to comply with in the given time period will result in a material and substantial violation.
 
| Failure to complete the initial restoration requirements as required under division (A) of section 1509.072 of the Revised Code. An area around the wellhead and along the uphill and downhill sides of the site is void of vegetative cover. The owner or the owner's agent shall grade or terrace and plant, seed, or sod the area disturbed that is not required in production of the well where necessary to bind the soil and prevent substantial erosion and sedimentation. Failure to comply with in the given time period will result in a material and substantial violation.
|
+
|  
| NONE5
+
|  
|
+
|
 +
|-
 +
|-
 +
| -38659367
 +
| 2011-09-26
 +
|
 +
| Called Tom Stone with Mountaineer State to see what depth of Berea Sandstone was.
 +
|
 +
|
 +
|
 +
|-
 +
|-
 +
| -465001405
 +
| 2011-09-07
 +
|
 +
| Predrilling site review with Tom Stone of Mountaineer State Oper LLC.
 +
|
 +
|
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 636871646
 
| 636871646
 
| 2012-06-25
 
| 2012-06-25
|
+
|  
 
| Erosion is under control.
 
| Erosion is under control.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -699495920
 +
| 2012-01-23
 +
|
 +
| Inspection revealed small oil leak on 2 inch line between mechanical separator and 100 barrel steel tank. Oil contamination radius is 1.5 feet around the 2 inch line. Took photos. Informed Tom Stone Mountaineer Field Supervisor of the leak, and instructed him to fix the leak and clean up the oil.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 757969285
 
| 757969285
 
| 2012-04-27
 
| 2012-04-27
|
+
|  
 
| There is erosion running down the hill roughly 120 feet. No vegetative cover has been established. Area shall be graded and vegetative cover shall be established in order to prevent erosion. There is a bailer on site next to the well. All drilling equipment shall be removed.
 
| There is erosion running down the hill roughly 120 feet. No vegetative cover has been established. Area shall be graded and vegetative cover shall be established in order to prevent erosion. There is a bailer on site next to the well. All drilling equipment shall be removed.
|
+
|  
| NONE5
+
|  
|
+
|
 +
|-
 +
|-
 +
| -814375289
 +
| 2012-10-31
 +
|
 +
| Follow up to inspection 385780457. The ground has been smoothed. The area has been reseeded and mulched. Vegetative cover has not yet been established. I will return on the due date to check for vegetative cove.
 +
|
 +
|
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 840269341
 
| 840269341
 
| 2011-09-20
 
| 2011-09-20
|
+
|  
 
| John Kent called and scheduled a Annular Disposal Mechanical Integrity Test (Fresh Water Test) on the surface casing. Test pressure 343 psi. 1st test (at 345 psi) lost 25 psi in 5 minutes. 2nd test (at 355 psi) lost 75 psi in 15 minutes. No further tests were done.
 
| John Kent called and scheduled a Annular Disposal Mechanical Integrity Test (Fresh Water Test) on the surface casing. Test pressure 343 psi. 1st test (at 345 psi) lost 25 psi in 5 minutes. 2nd test (at 355 psi) lost 75 psi in 15 minutes. No further tests were done.
|
+
|
|
+
|
|
+
|
 +
|-
 +
|-
 +
| -868784687
 +
| 2011-09-20
 +
|
 +
| Surface cement job. Ran 682 feet of new 26 lb 9 5/8 inch surface casing in 690 feet of 12 1/4 borehole. 265 sacks of class A, 300 lb gel, 800 lb accelerator, 240 lb LCM, with 60% excess. Circulation established and good cement returns stayed at surface.
 +
|  
 +
|  
 +
|  
 
|-
 
|-
 
|-
 
|-
 
| 974494694
 
| 974494694
 
| 2011-12-21
 
| 2011-12-21
|
+
|  
 
| Pits filled for two month preliminary restoration requirement. Some areas seeded and mulched, not all. Tank battery has been placed 50 feet from road. Well in production but ID has not been placed. Spoke with Tom Stone about ID.
 
| Pits filled for two month preliminary restoration requirement. Some areas seeded and mulched, not all. Tank battery has been placed 50 feet from road. Well in production but ID has not been placed. Spoke with Tom Stone about ID.
|
+
|  
|
+
|  
|
+
|  
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Ohio Department of Natural Resources RBDMS
 +
| publisher = [http://oilandgas.ohiodnr.gov/]
 +
| date = 2015-06-19
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection
 +
| accessdate = 2015-06-20 }}</ref>
 +
== References ==
 +
{{reflist}}
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 
[[Category:Wells]]
 
[[Category:Wells]]

Revision as of 07:04, 16 July 2015

Well Details

Well ID: 34-105-23677
Loading map...
County: Meigs
Municipality:
Operator Name: MOUNTAINEER STATE OPER LLC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2011-09-19
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 39.13731296
Longitude: -81.89569128

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2012-0 18.0 0.0
2013-0 0.0 0.0
2014-0 0.0 365.0 0.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
-1244569509 2012-12-04 Follow up to inspection 385780457. Pits filled, no erosion, no equipment on site, vegetative cover has returned.
1316438664 2011-09-19 Drilling status check. Spudded today and 22 feet of drive pipe set in bedrock. Pit construction looks good and large enough to handle water from Injun. 30 feet of surface borehole drilled now.
1316613904 2011-09-20 Running surface casing into hole. Last two joints don
1319463839 2011-10-21 Witnessed most of frac job on Gruesser well. 1978 PSI - breakdown, ~1000 PSI at 12.5 Bbl/min. When the water source was switched from pit to tanks, cuttings began to clog perfs. Pressured up to 2500 PSI and well was blown off in an attempt to clean out perfs. Attempted five times before success.
-1481718940 2012-05-21 Met with Tom Stone of Mountaineer State Operations to discuss erosion issues at well and remediation.
1499898447 2012-01-27 No violations were noted.
1518360589 2012-09-27 Inspection #757969285 has been voided because violation was given verbally. A written violation is being issued to the company today.
1552864618 2011-09-22 Kerry Brown of Monroe drilling let me know the hole had bridged off when the wire log had been run. Longstring to be delayed.
-212780482 2012-11-13 Follow up to inspection 385780457. The area has been graded, water bars have been emplaced along the road, and the area has been seeded and mulched. Grass is returning, but has covered less than 5% of the well site.
385780457 2012-09-27 Failure to complete the initial restoration requirements as required under division (A) of section 1509.072 of the Revised Code. An area around the wellhead and along the uphill and downhill sides of the site is void of vegetative cover. The owner or the owner's agent shall grade or terrace and plant, seed, or sod the area disturbed that is not required in production of the well where necessary to bind the soil and prevent substantial erosion and sedimentation. Failure to comply with in the given time period will result in a material and substantial violation.
-38659367 2011-09-26 Called Tom Stone with Mountaineer State to see what depth of Berea Sandstone was.
-465001405 2011-09-07 Predrilling site review with Tom Stone of Mountaineer State Oper LLC.
636871646 2012-06-25 Erosion is under control.
-699495920 2012-01-23 Inspection revealed small oil leak on 2 inch line between mechanical separator and 100 barrel steel tank. Oil contamination radius is 1.5 feet around the 2 inch line. Took photos. Informed Tom Stone Mountaineer Field Supervisor of the leak, and instructed him to fix the leak and clean up the oil.
757969285 2012-04-27 There is erosion running down the hill roughly 120 feet. No vegetative cover has been established. Area shall be graded and vegetative cover shall be established in order to prevent erosion. There is a bailer on site next to the well. All drilling equipment shall be removed.
-814375289 2012-10-31 Follow up to inspection 385780457. The ground has been smoothed. The area has been reseeded and mulched. Vegetative cover has not yet been established. I will return on the due date to check for vegetative cove.
840269341 2011-09-20 John Kent called and scheduled a Annular Disposal Mechanical Integrity Test (Fresh Water Test) on the surface casing. Test pressure 343 psi. 1st test (at 345 psi) lost 25 psi in 5 minutes. 2nd test (at 355 psi) lost 75 psi in 15 minutes. No further tests were done.
-868784687 2011-09-20 Surface cement job. Ran 682 feet of new 26 lb 9 5/8 inch surface casing in 690 feet of 12 1/4 borehole. 265 sacks of class A, 300 lb gel, 800 lb accelerator, 240 lb LCM, with 60% excess. Circulation established and good cement returns stayed at surface.
974494694 2011-12-21 Pits filled for two month preliminary restoration requirement. Some areas seeded and mulched, not all. Tank battery has been placed 50 feet from road. Well in production but ID has not been placed. Spoke with Tom Stone about ID.