If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-059-25210 | | Well ID: 37-059-25210 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="14" | {{#display_map: 39.900038, -80.066603 | width=100% | height=100% }} |
|- | |- | ||
− | | | + | | Country: United States |
|- | |- | ||
− | | | + | | State: Pennsylvania |
|- | |- | ||
− | | | + | | County: [[Greene_County,_Pennsylvania|Greene]] |
|- | |- | ||
− | | | + | | Municipality: [[Jefferson Township,_Greene_County,_Pennsylvania|Jefferson Township]] |
|- | |- | ||
− | | | + | | Operator Name: [[GREYLOCK PROD LLC]] |
|- | |- | ||
− | | | + | | Well Pad ID: [[150308]] |
|- | |- | ||
− | | | + | | Farm/Lease Name: SKIB 3MH |
|- | |- | ||
− | | | + | | License Status: Active |
|- | |- | ||
− | | | + | | Spud Date: 11/18/2010 |
|- | |- | ||
− | | | + | | Permit Date: 5/28/2009 |
|- | |- | ||
− | | Well | + | | Unconventional Well: Y |
|- | |- | ||
− | | | + | | Configuration: Horizontal Well |
|- | |- | ||
| Latitude: 39.900038 | | Latitude: 39.900038 | ||
|- | |- | ||
− | | Longitude: -80. | + | | Longitude: -80.066603 |
− | |||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Permits Issued Detail Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref><ref>{{cite web | ||
+ | | title = Spud Data Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-04-30 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-16 }}</ref><ref>{{cite web | ||
+ | | title = Oil and Gas Well Pad Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Operator Name |
− | !scope="col" | | + | !scope="col" | Gas Quantity (mcf) |
− | !scope="col" | | + | !scope="col" | Gas Production Days |
− | !scope="col" | | + | !scope="col" | Oil Quantity (bbl) |
− | !scope="col" | | + | !scope="col" | Oil Production Days |
− | !scope="col" | | + | !scope="col" | Water Quantity (bbl) |
− | + | !scope="col" | Water Production Days | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2009 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
− | | | + | | 2010 |
− | | style="text-align:right;" | | + | | [[ENERGY CORP OF AMER]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2011 | ||
+ | | [[ENERGY CORP OF AMER]] | ||
+ | | style="text-align: right;" | 627,123.00 | ||
+ | | style="text-align: right;" | 234 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2012 |
− | | style="text-align:right;" | | + | | [[ENERGY CORP OF AMER]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 576,254.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 366 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2013 | ||
+ | | [[ENERGY CORP OF AMER]] | ||
+ | | style="text-align: right;" | 383,540.00 | ||
+ | | style="text-align: right;" | 365 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | 2014 | + | | 2014 |
− | | style="text-align:right;" | | + | | [[ENERGY CORP OF AMER]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 266,690.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 323 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | 0 | + | | style="text-align: right;" | 0.00 |
− | + | | style="text-align: right;" | 0 | |
|- | |- | ||
− | | 2015 | + | | 2015 |
− | | style="text-align:right;" | | + | | [[ENERGY CORP OF AMER]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 292,168.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 360 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2016 | ||
+ | | [[ENERGY CORP OF AMER]] | ||
+ | | style="text-align: right;" | 224,991.00 | ||
+ | | style="text-align: right;" | 363 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2017 |
− | | style="text-align:right;" | | + | | [[ENERGY CORP OF AMER]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 181,402.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 363 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2018 | ||
+ | | [[ENERGY CORP OF AMER]] | ||
+ | | style="text-align: right;" | 163,878.00 | ||
+ | | style="text-align: right;" | 362 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2019 |
− | | style="text-align:right;" | | + | | [[GREYLOCK PROD LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 34,621.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 90 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Production Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
== Waste Data == | == Waste Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Waste Type |
− | !scope="col" | | + | !scope="col" | Quantity |
− | !scope="col" | | + | !scope="col" | Disposal Method |
− | !scope="col" | | + | !scope="col" | Waste Facility ID |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2011-1 | | 2011-1 | ||
− | | | + | | Drill Cuttings (in Tons) |
− | | style="text-align:right;" | 755.99 | + | | style="text-align: right;" | 755.99 Tons |
− | |||
| LANDFILL | | LANDFILL | ||
| 100172 | | 100172 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2011-1 | | 2011-1 | ||
− | | | + | | Drilling Fluid Waste (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 2,907.00 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2011-1 | | 2011-1 | ||
− | | | + | | Fracing Fluid Waste (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 6,356.00 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2011-1 | | 2011-1 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 23,322.00 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2011-1 | | 2011-1 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | + | | style="text-align: right;" | 2,220.00 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | style="text-align:right;" | 2. | ||
− | |||
| STORAGE PENDING DISPOSAL OR REUSE | | STORAGE PENDING DISPOSAL OR REUSE | ||
| | | | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2011-2 | | 2011-2 | ||
− | | | + | | Drill Cuttings (in Tons) |
− | | style="text-align:right;" | 11.03 | + | | style="text-align: right;" | 11.03 Tons |
− | |||
| LANDFILL | | LANDFILL | ||
| 100172 | | 100172 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2011-2 | | 2011-2 | ||
− | | | + | | Drill Cuttings (in Tons) |
− | | style="text-align:right;" | 13.06 | + | | style="text-align: right;" | 13.06 Tons |
− | |||
| LANDFILL | | LANDFILL | ||
| SWF 1032-WV0109 | | SWF 1032-WV0109 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2011-2 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 279.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
| 2011-2 | | 2011-2 | ||
− | | | + | | Fracturing Fluid Waste (in Tons) |
− | | style="text-align:right;" | 4.95 | + | | style="text-align: right;" | 4.95 Tons |
− | |||
| LANDFILL | | LANDFILL | ||
| 100172 | | 100172 | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2011-2 | | 2011-2 | ||
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 4,163.00 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | | | + | |- |
+ | | 2012-1 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 285.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | |||
|- | |- | ||
+ | | 2012-2 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 1,833.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2013-1 |
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 595.00 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2013-2 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 120.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
+ | |- | ||
+ | | 2014-1 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 505.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
+ | | 2014-2 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 339.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2015-1 |
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 385.00 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2015-2 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 90.00 Bbl | ||
+ | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
+ | | WMGR123SW010 | ||
+ | |- | ||
+ | | 2015-2 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 180.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
+ | |- | ||
+ | | 2016-1 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 116.00 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | WMGR123SW019 | ||
+ | |- | ||
+ | | 2016-1 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 90.00 Bbl | ||
+ | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
+ | | WMGR123SW001 | ||
+ | |- | ||
+ | | 2016-1 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 110.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
+ | | 2016-1 | ||
+ | | Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | ||
+ | | style="text-align: right;" | 1.27 Tons | ||
+ | | LANDFILL | ||
+ | | 100419 | ||
+ | |- | ||
+ | | 2016-2 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 95.00 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW001 | ||
|- | |- | ||
− | | | + | | 2016-2 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 42.00 Bbl |
− | | Bbl | + | | RESIDUAL WASTE PROCESSING FACILITY |
+ | | WMGR123SW010 | ||
+ | |- | ||
+ | | 2016-2 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 375.00 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2017-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 55.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2017-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 100.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
+ | | 2017-05 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 65.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2017-06 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 55.00 Bbl |
− | + | | REUSE (AT WELL PAD) | |
− | | REUSE | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2017-09 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 60.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2017-10 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 75.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
+ | | 2017-11 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 45.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2018-01 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 47.00 Bbl |
− | + | | REUSE (AT WELL PAD) | |
− | | REUSE | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2018-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 90.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2018-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 90.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
+ | | 2018-05 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 100.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2018-06 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 70.00 Bbl |
− | + | | REUSE (AT WELL PAD) | |
− | | REUSE | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2018-08 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 51.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2018-10 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 55.00 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW005 | ||
+ | |- | ||
+ | | 2018-10 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 30.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
+ | | 2018-11 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 22.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2018-12 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 50.00 Bbl |
− | | Bbl | + | | RESIDUAL WASTE PROCESSING FACILITY |
− | | REUSE | + | | WMGR123SW019 |
+ | |- | ||
+ | | 2019-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 83.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2019-02 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 38.80 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2019-02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 23.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2019-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 30.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Waste Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
== Inspection Data == | == Inspection Data == | ||
+ | ==== Inspections Performed ==== | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Inspection ID |
− | !scope="col" | | + | !scope="col" | Inspection Category |
− | !scope="col" | | + | !scope="col" | Inspection Date |
− | !scope="col" | | + | !scope="col" | Inspection Type |
− | !scope="col" | | + | !scope="col" | Inspection Result |
− | + | !scope="col" | Inspection Comments | |
− | !scope="col" | | ||
|- | |- | ||
| 2008079 | | 2008079 | ||
− | | | + | | Primary Facility |
+ | | 10/04/2011 | ||
+ | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| Well drilled and in line; location reclaimed; E&S good | | Well drilled and in line; location reclaimed; E&S good | ||
+ | |- | ||
+ | | 2016929 | ||
+ | | Primary Facility | ||
+ | | 10/11/2011 | ||
+ | | Drilling/Alteration | ||
+ | | No Violations Noted | ||
+ | | WELL IS HOOKED UP AND PRODUCING. | ||
+ | |- | ||
+ | | 2375243 | ||
+ | | Primary Facility | ||
+ | | 04/14/2015 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | Well completed and is in production. Well in compliance. | ||
+ | |- | ||
+ | | 2415732 | ||
+ | | Primary Facility | ||
+ | | 09/04/2015 | ||
+ | | Routine/Partial Inspection | ||
+ | | No Violations Noted | ||
+ | | On 9/4/15, I inspected the Skib A and B Pads with DEP Engineer Dr. Tae-Uk Kim and DEP Biologist Samantha Sullivan and made the following observations: | ||
+ | |- | ||
+ | | 2448921 | ||
+ | | Primary Facility | ||
+ | | 2016-02-05 | ||
+ | | Compliance Evaluation | ||
+ | | No Violations Noted | ||
+ | | On 2/5/16, I performed a compliance evaluation inspection at the Skib A & B Unit Site in response to a previous inspection from 9/4/15 (2415691) that resulted in multiple violations and made the following observations: | ||
+ | •Inconsistencies in pad construction and unmarked wetland areas have been addressed… | ||
+ | •At the time of inspection the impoundment on site was full with the liner in place… | ||
+ | •The non-permitted access road noted during the 9/4/15 inspection was reported by ECA to be… | ||
+ | •The sediment trap that was found to previously be in poor condition had been renovated… | ||
+ | |||
+ | Conclusion: | ||
+ | •All violations noted in NOV from the 9/4/15 inspection appear to have been satisfactorily resolved. | ||
+ | •No additional violations were noted at the time of inspection. Issues related to the impoundment will be followed up on in summer 2016. | ||
+ | |- | ||
+ | |} | ||
+ | <!--==== Violations Commited ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Inspection ID | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Violation Date | ||
+ | !scope="col" | Date Resolved | ||
+ | !scope="col" | Violation Code | ||
+ | !scope="col" | Violation Type | ||
+ | !scope="col" | Violation Comments | ||
+ | |- | ||
+ | |}--> | ||
+ | <!--==== Penalties Applied ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Penalty ID | ||
+ | !scope="col" | Penalty Code | ||
+ | !scope="col" | Penalty Status | ||
+ | !scope="col" | Penalty Date | ||
+ | !scope="col" | Enforcement Date | ||
+ | !scope="col" | Penalty Amount | ||
+ | !scope="col" | Amount Collected | ||
+ | |- | ||
+ | |}--> | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =Oil and Gas Compliance Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 04/17/2011 | ||
+ | | 04/17/2011 | ||
+ | | style="text-align: right;" | 8030.00 | ||
+ | | style="text-align: right;" | 3,621,198.0 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="27"| 1 | ||
+ | | rowspan="1"| LP-65 | ||
+ | | rowspan="1"| Halliburton Energy Services | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Ammonium chloride | ||
+ | | 12125-02-9 | ||
+ | | style="text-align: right;" | 10.00 | ||
+ | | style="text-align: right;" | 0.00064000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| HAI-OS ACID INHIBITOR | ||
+ | | rowspan="2"| Halliburton Energy Services | ||
+ | | rowspan="2"| Corrosion Inhibitor for Acid | ||
+ | | Methanol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 60.00 | ||
+ | | style="text-align: right;" | 0.00011000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Propargyl alcohol | ||
+ | | 107-19-7 | ||
+ | | style="text-align: right;" | 10.00 | ||
+ | | style="text-align: right;" | 0.00002000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| GW-3LDF | ||
+ | | rowspan="2"| BJ Services Company | ||
+ | | rowspan="2"| Liquid Gel | ||
+ | | Polysaccharide blend | ||
| | | | ||
+ | | style="text-align: right;" | 60.00 | ||
+ | | style="text-align: right;" | 0.00480000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Petroleum distillate blend | ||
| | | | ||
+ | | style="text-align: right;" | 60.00 | ||
+ | | style="text-align: right;" | 0.00480000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| CI-14 | ||
+ | | rowspan="2"| BJ Services Company | ||
+ | | rowspan="2"| Corrosion Inhibitor for Acid | ||
+ | | Methanol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 68.00 | ||
+ | | style="text-align: right;" | 0.00053000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Propargyl alcohol | ||
| | | | ||
+ | | style="text-align: right;" | 5.00 | ||
+ | | style="text-align: right;" | 0.00004000 | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Ferrotrol 300L | ||
+ | | rowspan="1"| BJ Services Company | ||
+ | | rowspan="1"| Iron Control for Acid | ||
+ | | Citric acid | ||
+ | | 77-92-9 | ||
+ | | style="text-align: right;" | 70.00 | ||
+ | | style="text-align: right;" | 0.00236000 | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="1"| Sand-Premium Plus, 40/70, HES |
− | | | + | | rowspan="1"| Halliburton Energy Services |
− | | | + | | rowspan="1"| Proppant |
− | + | | Quartz | |
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 100.00 | ||
+ | | style="text-align: right;" | 1.41 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="4"| Alpha 1427 | ||
+ | | rowspan="4"| BJ Services Company | ||
+ | | rowspan="4"| Biocide | ||
+ | | Ethanol | ||
+ | | 64-17-5 | ||
+ | | style="text-align: right;" | 5.00 | ||
+ | | style="text-align: right;" | 0.00055000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides | ||
+ | | 68424-85-1 | ||
+ | | style="text-align: right;" | 7.00 | ||
+ | | style="text-align: right;" | 0.00077000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Didecyl dimethyl ammonium chloride | ||
+ | | 7173-51-5 | ||
+ | | style="text-align: right;" | 10.00 | ||
+ | | style="text-align: right;" | 0.00110000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Glutaraldehyde | ||
+ | | 111-30-8 | ||
+ | | style="text-align: right;" | 30.00 | ||
+ | | style="text-align: right;" | 0.00329000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| GBW-30 BREAKER | ||
+ | | rowspan="2"| Halliburton Energy Services | ||
+ | | rowspan="2"| Breaker | ||
+ | | Hemicellulase enzyme | ||
+ | | 9012-54-8 | ||
+ | | style="text-align: right;" | 15.00 | ||
+ | | style="text-align: right;" | 0.00007000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Carbohydrates | ||
| | | | ||
+ | | style="text-align: right;" | 95.00 | ||
+ | | style="text-align: right;" | 0.00046000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| BE-9M | ||
+ | | rowspan="2"| Halliburton Energy Services | ||
+ | | rowspan="2"| Biocide | ||
+ | | Methanol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 30.00 | ||
+ | | style="text-align: right;" | 0.00063000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Tri-n-butyl tetradecyl phosphonium chloride | ||
+ | | 81741-28-8 | ||
+ | | style="text-align: right;" | 10.00 | ||
+ | | style="text-align: right;" | 0.00021000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| 15 Hydrochloric Acid (BJ) | ||
+ | | rowspan="1"| BJ Services Company | ||
+ | | rowspan="1"| Acid | ||
+ | | Hydrochloric acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 15.00 | ||
+ | | style="text-align: right;" | 0.07 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Sand-Prem White-40/70, BJ | ||
+ | | rowspan="1"| BJ Services Company | ||
+ | | rowspan="1"| Proppant | ||
+ | | Quartz | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 100.00 | ||
+ | | style="text-align: right;" | 6.04 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| WG-36 GELLING AGENT | ||
+ | | rowspan="1"| Halliburton Energy Services | ||
+ | | rowspan="1"| Dry Gellant | ||
+ | | Guar gum | ||
+ | | 9000-30-0 | ||
+ | | style="text-align: right;" | 100.00 | ||
+ | | style="text-align: right;" | 0.01 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Water | ||
+ | | rowspan="1"| ECA | ||
+ | | rowspan="1"| Base Fluid | ||
| | | | ||
| | | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | 90.24 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| FR-66 Friction Reducer | ||
+ | | rowspan="1"| Halliburton Energy Services | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Distillates, petroleum, hydrotreated light | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 30.00 | ||
+ | | style="text-align: right;" | 0.00498000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| FRW-18 | ||
+ | | rowspan="1"| BJ Services Company | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Distillates, petroleum, hydrotreated light | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 30.00 | ||
+ | | style="text-align: right;" | 0.01 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| 15 HCl TH | ||
+ | | rowspan="1"| Halliburton Energy Services | ||
+ | | rowspan="1"| Acid | ||
+ | | Hydrochloric acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 15.00 | ||
+ | | style="text-align: right;" | 0.02 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Sand-Premium Plus, 100 Mesh, HES | ||
+ | | rowspan="1"| Halliburton Energy Services | ||
+ | | rowspan="1"| Proppant | ||
+ | | Quartz | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 100.00 | ||
+ | | style="text-align: right;" | 0.54 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| SP Breaker | ||
+ | | rowspan="1"| Halliburton Energy Services | ||
+ | | rowspan="1"| Breaker | ||
+ | | Sodium persulfate | ||
+ | | 7775-27-1 | ||
+ | | style="text-align: right;" | 100.00 | ||
+ | | style="text-align: right;" | 0.00080000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Sand-Prem White-100 Mesh, BJ | ||
+ | | rowspan="1"| BJ Services Company | ||
+ | | rowspan="1"| Proppant | ||
+ | | Quartz | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 100.00 | ||
+ | | style="text-align: right;" | 1.59 | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = | + | | title =FracFocus Fracking Chemicals Database |
− | + | | date = 2019-04-02 | |
− | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | accessdate = 2019-06-19 }}</ref> |
− | | accessdate = | + | ==References== |
− | == References == | + | <references/> |
− | |||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
− | [[Category:Wells]] | + | [[Category:Pennsylvania Wells]] |
+ | [[Category:FracFocus]] |
Well ID: 37-059-25210 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.900038,"lon":-80.066603,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Jefferson Township | |
Operator Name: GREYLOCK PROD LLC | |
Well Pad ID: 150308 | |
Farm/Lease Name: SKIB 3MH | |
License Status: Active | |
Spud Date: 11/18/2010 | |
Permit Date: 5/28/2009 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 39.900038 | |
Longitude: -80.066603 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | 0.00 | 0.00 | 0.00 | ||||
2010 | ENERGY CORP OF AMER | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | ENERGY CORP OF AMER | 627,123.00 | 234 | 0.00 | 0 | 0.00 | 0 |
2012 | ENERGY CORP OF AMER | 576,254.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2013 | ENERGY CORP OF AMER | 383,540.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | ENERGY CORP OF AMER | 266,690.00 | 323 | 0.00 | 0 | 0.00 | 0 |
2015 | ENERGY CORP OF AMER | 292,168.00 | 360 | 0.00 | 0 | 0.00 | 0 |
2016 | ENERGY CORP OF AMER | 224,991.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2017 | ENERGY CORP OF AMER | 181,402.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2018 | ENERGY CORP OF AMER | 163,878.00 | 362 | 0.00 | 0 | 0.00 | 0 |
2019 | GREYLOCK PROD LLC | 34,621.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2011-1 | Drill Cuttings (in Tons) | 755.99 Tons | LANDFILL | 100172 |
2011-1 | Drilling Fluid Waste (in Barrels) | 2,907.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011-1 | Fracing Fluid Waste (in Barrels) | 6,356.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011-1 | Produced Fluid (in Barrels) | 23,322.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011-1 | Produced Fluid (in Barrels) | 2,220.00 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2011-2 | Drill Cuttings (in Tons) | 11.03 Tons | LANDFILL | 100172 |
2011-2 | Drill Cuttings (in Tons) | 13.06 Tons | LANDFILL | SWF 1032-WV0109 |
2011-2 | Fracing Fluid Waste (in Barrels) | 279.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011-2 | Fracturing Fluid Waste (in Tons) | 4.95 Tons | LANDFILL | 100172 |
2011-2 | Produced Fluid (in Barrels) | 4,163.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-1 | Produced Fluid (in Barrels) | 285.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-2 | Produced Fluid (in Barrels) | 1,833.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-1 | Produced Fluid (in Barrels) | 595.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-2 | Produced Fluid (in Barrels) | 120.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-1 | Produced Fluid (in Barrels) | 505.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-2 | Produced Fluid (in Barrels) | 339.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-1 | Produced Fluid (in Barrels) | 385.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-2 | Produced Fluid (in Barrels) | 90.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW010 |
2015-2 | Produced Fluid (in Barrels) | 180.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 116.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 90.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-1 | Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | 1.27 Tons | LANDFILL | 100419 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 95.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 42.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 375.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017-02 | Produced Fluid (in Barrels) RWC 802 | 55.00 Bbl | REUSE (AT WELL PAD) | |
2017-03 | Produced Fluid (in Barrels) RWC 802 | 100.00 Bbl | REUSE (AT WELL PAD) | |
2017-05 | Produced Fluid (in Barrels) RWC 802 | 65.00 Bbl | REUSE (AT WELL PAD) | |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 55.00 Bbl | REUSE (AT WELL PAD) | |
2017-09 | Produced Fluid (in Barrels) RWC 802 | 60.00 Bbl | REUSE (AT WELL PAD) | |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 75.00 Bbl | REUSE (AT WELL PAD) | |
2017-11 | Produced Fluid (in Barrels) RWC 802 | 45.00 Bbl | REUSE (AT WELL PAD) | |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 47.00 Bbl | REUSE (AT WELL PAD) | |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 90.00 Bbl | REUSE (AT WELL PAD) | |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 90.00 Bbl | REUSE (AT WELL PAD) | |
2018-05 | Produced Fluid (in Barrels) RWC 802 | 100.00 Bbl | REUSE (AT WELL PAD) | |
2018-06 | Produced Fluid (in Barrels) RWC 802 | 70.00 Bbl | REUSE (AT WELL PAD) | |
2018-08 | Produced Fluid (in Barrels) RWC 802 | 51.00 Bbl | REUSE (AT WELL PAD) | |
2018-10 | Produced Fluid (in Barrels) RWC 802 | 55.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-10 | Produced Fluid (in Barrels) RWC 802 | 30.00 Bbl | REUSE (AT WELL PAD) | |
2018-11 | Produced Fluid (in Barrels) RWC 802 | 22.00 Bbl | REUSE (AT WELL PAD) | |
2018-12 | Produced Fluid (in Barrels) RWC 802 | 50.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019-01 | Produced Fluid (in Barrels) RWC 802 | 83.00 Bbl | REUSE (AT WELL PAD) | |
2019-02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 38.80 Bbl | REUSE (AT WELL PAD) | |
2019-02 | Produced Fluid (in Barrels) RWC 802 | 23.00 Bbl | REUSE (AT WELL PAD) | |
2019-03 | Produced Fluid (in Barrels) RWC 802 | 30.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2008079 | Primary Facility | 10/04/2011 | Drilling/Alteration | No Violations Noted | Well drilled and in line; location reclaimed; E&S good |
2016929 | Primary Facility | 10/11/2011 | Drilling/Alteration | No Violations Noted | WELL IS HOOKED UP AND PRODUCING. |
2375243 | Primary Facility | 04/14/2015 | Routine/Complete Inspection | No Violations Noted | Well completed and is in production. Well in compliance. |
2415732 | Primary Facility | 09/04/2015 | Routine/Partial Inspection | No Violations Noted | On 9/4/15, I inspected the Skib A and B Pads with DEP Engineer Dr. Tae-Uk Kim and DEP Biologist Samantha Sullivan and made the following observations: |
2448921 | Primary Facility | 2016-02-05 | Compliance Evaluation | No Violations Noted | On 2/5/16, I performed a compliance evaluation inspection at the Skib A & B Unit Site in response to a previous inspection from 9/4/15 (2415691) that resulted in multiple violations and made the following observations:
•Inconsistencies in pad construction and unmarked wetland areas have been addressed… •At the time of inspection the impoundment on site was full with the liner in place… •The non-permitted access road noted during the 9/4/15 inspection was reported by ECA to be… •The sediment trap that was found to previously be in poor condition had been renovated… Conclusion: •All violations noted in NOV from the 9/4/15 inspection appear to have been satisfactorily resolved. •No additional violations were noted at the time of inspection. Issues related to the impoundment will be followed up on in summer 2016. |
For data sources see[6]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 04/17/2011 | 04/17/2011 | 8030.00 | 3,621,198.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | LP-65 | Halliburton Energy Services | Scale Inhibitor | Ammonium chloride | 12125-02-9 | 10.00 | 0.00064000 | |
HAI-OS ACID INHIBITOR | Halliburton Energy Services | Corrosion Inhibitor for Acid | Methanol | 67-56-1 | 60.00 | 0.00011000 | ||
Propargyl alcohol | 107-19-7 | 10.00 | 0.00002000 | |||||
GW-3LDF | BJ Services Company | Liquid Gel | Polysaccharide blend | 60.00 | 0.00480000 | |||
Petroleum distillate blend | 60.00 | 0.00480000 | ||||||
CI-14 | BJ Services Company | Corrosion Inhibitor for Acid | Methanol | 67-56-1 | 68.00 | 0.00053000 | ||
Propargyl alcohol | 5.00 | 0.00004000 | ||||||
Ferrotrol 300L | BJ Services Company | Iron Control for Acid | Citric acid | 77-92-9 | 70.00 | 0.00236000 | ||
Sand-Premium Plus, 40/70, HES | Halliburton Energy Services | Proppant | Quartz | 14808-60-7 | 100.00 | 1.41 | ||
Alpha 1427 | BJ Services Company | Biocide | Ethanol | 64-17-5 | 5.00 | 0.00055000 | ||
Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides | 68424-85-1 | 7.00 | 0.00077000 | |||||
Didecyl dimethyl ammonium chloride | 7173-51-5 | 10.00 | 0.00110000 | |||||
Glutaraldehyde | 111-30-8 | 30.00 | 0.00329000 | |||||
GBW-30 BREAKER | Halliburton Energy Services | Breaker | Hemicellulase enzyme | 9012-54-8 | 15.00 | 0.00007000 | ||
Carbohydrates | 95.00 | 0.00046000 | ||||||
BE-9M | Halliburton Energy Services | Biocide | Methanol | 67-56-1 | 30.00 | 0.00063000 | ||
Tri-n-butyl tetradecyl phosphonium chloride | 81741-28-8 | 10.00 | 0.00021000 | |||||
15 Hydrochloric Acid (BJ) | BJ Services Company | Acid | Hydrochloric acid | 7647-01-0 | 15.00 | 0.07 | ||
Sand-Prem White-40/70, BJ | BJ Services Company | Proppant | Quartz | 14808-60-7 | 100.00 | 6.04 | ||
WG-36 GELLING AGENT | Halliburton Energy Services | Dry Gellant | Guar gum | 9000-30-0 | 100.00 | 0.01 | ||
Water | ECA | Base Fluid | 90.24 | |||||
FR-66 Friction Reducer | Halliburton Energy Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.00498000 | ||
FRW-18 | BJ Services Company | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.01 | ||
15 HCl TH | Halliburton Energy Services | Acid | Hydrochloric acid | 7647-01-0 | 15.00 | 0.02 | ||
Sand-Premium Plus, 100 Mesh, HES | Halliburton Energy Services | Proppant | Quartz | 14808-60-7 | 100.00 | 0.54 | ||
SP Breaker | Halliburton Energy Services | Breaker | Sodium persulfate | 7775-27-1 | 100.00 | 0.00080000 | ||
Sand-Prem White-100 Mesh, BJ | BJ Services Company | Proppant | Quartz | 14808-60-7 | 100.00 | 1.59 |
For data sources see[7]