X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-059-25678"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-059-25678
 
| Well ID: 37-059-25678
| style="height=100%; align=center" rowspan="15" | {{#display_map: 39.997266, -80.301394 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="14" | {{#display_map: 39.997267, -80.301394 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Greene County, Pennsylvania|Greene]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Morris Township, Greene County, Pennsylvania|Morris Township]]
+
| State: Pennsylvania
 +
|-
 +
| County: [[Greene_County,_Pennsylvania|Greene]]
 +
|-
 +
| Municipality: [[Morris Township,_Greene_County,_Pennsylvania|Morris Township]]
 
|-
 
|-
 
| Operator Name: [[CNX GAS CO LLC]]
 
| Operator Name: [[CNX GAS CO LLC]]
 
|-
 
|-
| Well Pad ID: [[148914|148914]]
+
| Well Pad ID: [[148914]]
 
|-
 
|-
 
| Farm/Lease Name: MOONEY NV48EHS
 
| Farm/Lease Name: MOONEY NV48EHS
 
|-
 
|-
| First Permit Date: 2011-02-25
+
| License Status: Active
 +
|-
 +
| Spud Date: 06/04/2011
 +
|-
 +
| Permit Date: 2/25/2011
 +
|-
 +
| Unconventional Well: Y
 +
|-
 +
| Configuration: Horizontal Well
 +
|-
 +
| Latitude: 39.997267
 +
|-
 +
| Longitude: -80.301394
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator Name
 +
!scope="col" | Gas Quantity (mcf)
 +
!scope="col" | Gas Production Days
 +
!scope="col" | Oil Quantity (bbl)
 +
!scope="col" | Oil Production Days
 +
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 +
|-
 +
| 2010
 +
| [[CNX GAS CO LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2011
 +
| [[CNX GAS CO LLC]]
 +
| style="text-align: right;" | 6,176.67
 +
| style="text-align: right;" | 3
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Last Permit Date: 2011-02-25
+
| 2012
 +
| [[CNX GAS CO LLC]]
 +
| style="text-align: right;" | 684,266.94
 +
| style="text-align: right;" | 366
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Spud Date: 2011-06-04
+
| 2013
 +
| [[CNX GAS CO LLC]]
 +
| style="text-align: right;" | 253,525.18
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Unconventional: Yes
+
| 2014
 +
| [[CNX GAS CO LLC]]
 +
| style="text-align: right;" | 320,994.59
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Horizontal: Yes
+
| 2015
 +
| [[CNX GAS CO LLC]]
 +
| style="text-align: right;" | 293,181.35
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Well Status: ACTIVE
+
| 2016
 +
| [[CNX GAS CO LLC]]
 +
| style="text-align: right;" | 239,473.33
 +
| style="text-align: right;" | 366
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Violations: 0
+
| 2017
 +
| [[CNX GAS CO LLC]]
 +
| style="text-align: right;" | 261,168.92
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Latitude: 39.997266
+
| 2018
 +
| [[CNX GAS CO LLC]]
 +
| style="text-align: right;" | 176,519.95
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Longitude: -80.301394
+
| 2019
 +
| [[CNX GAS CO LLC]]
 +
| style="text-align: right;" | 29,529.38
 +
| style="text-align: right;" | 90
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 
|}
 
|}
== Production Data ==
+
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Waste Type
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Quantity
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Disposal Method
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Waste Facility ID
!scope="col" | OIL QUANTITY
+
|-
!scope="col" | OIL PRODUCTION DAYS
+
| 15AUGU
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 907.62 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 15DECU
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 694.64 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 15JULU
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 1,192.85 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 15NOVU
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 742.28 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 15OCTU
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 779.35 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 15SEPU
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 832.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 16APRU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 505.94 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 16AUGU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 445.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 16DECU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 386.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 16FEBU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 455.67 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2010-2
+
| 16JANU
| style="text-align:right;" | 0.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 712.29 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 16JULU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 471.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2010-2
+
| 16JUNU
| style="text-align:right;" | 0.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 86.40 Bbl
| style="text-align:right;" | 0.0
+
| INJECTION DISPOSAL WELL
| style="text-align:right;" | 0.0
+
| 34-013-20609
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 16JUNU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 42.84 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 
|-
 
|-
| 2010-2
+
| 16JUNU
| style="text-align:right;" | 0.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 331.35 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 16MARU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 628.64 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2010-2
+
| 16MAYU
| style="text-align:right;" | 0.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 17.14 Bbl
| style="text-align:right;" | 0.0
+
| INJECTION DISPOSAL WELL
| style="text-align:right;" | 0.0
+
| 34-013-20609
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 16MAYU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 25.76 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 
|-
 
|-
| 2011-1
+
| 16MAYU
| style="text-align:right;" | 0.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 474.16 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 16NOVU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 26.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-013-20609
 
|-
 
|-
| 2011-1
+
| 16NOVU
| style="text-align:right;" | 0.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 84.00 Bbl
| style="text-align:right;" | 0.0
+
| INJECTION DISPOSAL WELL
| style="text-align:right;" | 0.0
+
| 34-119-28803
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 16NOVU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 316.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 16OCTU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 77.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-013-20609
 +
|-
 +
| 16OCTU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28780
 +
|-
 +
| 16OCTU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 163.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 +
|-
 +
| 16OCTU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 144.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 16SEPU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 417.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
 
| 2011-2
 
| 2011-2
| style="text-align:right;" | 6176.67
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 3.0
+
| style="text-align: right;" | 345.43 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2012-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 49.59 Bbl
 +
| LANDFILL
 +
| 100277
 
|-
 
|-
 
| 2012-1
 
| 2012-1
| style="text-align:right;" | 400052.44
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 182.0
+
| style="text-align: right;" | 2,832.01 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2012-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 37.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-013-20609
 
|-
 
|-
 
| 2012-2
 
| 2012-2
| style="text-align:right;" | 284214.5
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 184.0
+
| style="text-align: right;" | 27.00 Bbl
| style="text-align:right;" | 0.0
+
| INJECTION DISPOSAL WELL
| style="text-align:right;" | 0.0
+
| 34-031-27177
| style="text-align:right;" | 0.0
+
|-
| style="text-align:right;" | 0.0
+
| 2012-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 65.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-121-23995
 
|-
 
|-
 +
| 2012-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 586.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
 
| 2013-1
 
| 2013-1
| style="text-align:right;" | 218257.9
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 181.0
+
| style="text-align: right;" | 757.48 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
+
|-
| style="text-align:right;" | 0.0
+
| 2013-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 13.61 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-013-20609
 
|-
 
|-
 +
| 2013-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 9.68 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-031-27177
 
|-
 
|-
 
| 2013-2
 
| 2013-2
| style="text-align:right;" | 35267.28
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 184.0
+
| style="text-align: right;" | 5.30 Bbl
| style="text-align:right;" | 0.0
+
| INJECTION DISPOSAL WELL
| style="text-align:right;" | 0.0
+
| 34-059-24202
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2013-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 37.88 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-105-23619
 +
|-
 +
| 2013-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 0.50 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28776
 +
|-
 +
| 2013-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 473.08 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
 
| 2014-1
 
| 2014-1
| style="text-align:right;" | 173297.93
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 181.0
+
| style="text-align: right;" | 2.48 Bbl
| style="text-align:right;" | 0.0
+
| INJECTION DISPOSAL WELL
| style="text-align:right;" | 0.0
+
| 2D0859721
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2014-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 11.39 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-013-20609
 
|-
 
|-
| 2014-2
+
| 2014-1
| style="text-align:right;" | 147696.66
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 184.0
+
| style="text-align: right;" | 9.41 Bbl
| style="text-align:right;" | 0.0
+
| INJECTION DISPOSAL WELL
| style="text-align:right;" | 0.0
+
| 34-059-24202
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2014-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 2.48 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28776
 
|-
 
|-
| 2015-02
+
| 2014-1
| style="text-align:right;" | 27798.58
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 28.0
+
| style="text-align: right;" | 2.97 Bbl
| style="text-align:right;" | 0.0
+
| INJECTION DISPOSAL WELL
| style="text-align:right;" | 0.0
+
| 34-121-23995
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2014-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 285.85 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2015-01
+
| 2014-1
| style="text-align:right;" | 23269.59
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 31.0
+
| style="text-align: right;" | 20.79 Bbl
| style="text-align:right;" | 0.0
+
| STORAGE PENDING DISPOSAL OR REUSE
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2014-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 57.50 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2015-03
+
| 2015-07
| style="text-align:right;" | 28224.59
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 31.0
+
| style="text-align: right;" | 1,192.85 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
|}
+
| 2015-08
For data sources see<ref>{{cite web
+
| Produced Fluid (in Barrels)
| title = Oil and Gas Historical Production Report
+
| style="text-align: right;" | 907.62 Bbl
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| REUSE OTHER THAN ROAD SPREADING
| date = 2015-05-26
+
|  
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
 
| accessdate = 2015-05-27 }}</ref>
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | PERIOD
 
!scope="col" | TYPE
 
!scope="col" | QUANTITY
 
!scope="col" | UNITS
 
!scope="col" | DISPOSAL METHOD
 
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
| 2011-2
+
| 2015-09
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 345.43
+
| style="text-align: right;" | 832.00 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE OF BRINE TO FRAC A WELL
+
|-
 +
| 2015-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 12,919.72 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2015-10
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 779.35 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
 +
| 2015-11
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 742.28 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2012-1
+
| 2015-12
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 2.0
+
| style="text-align: right;" | 694.64 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR HYDRAULIC FRACTURING
+
|-
 +
| 2016-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 712.29 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2016-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 455.67 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
 +
| 2016-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 628.64 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2012-1
+
| 2016-04
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 49.59
+
| style="text-align: right;" | 505.94 Bbl
| Bbl
+
| REUSE OTHER THAN ROAD SPREADING
| LANDFILL
+
|  
| 100277
 
| WESTMORELAND WASTE LLC SANITARY LANDFILL
 
| BELLE VERNON
 
| PA
 
 
|-
 
|-
 +
| 2016-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 17.14 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-013-20609
 
|-
 
|-
| 2012-2
+
| 2016-05
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 27.0
+
| style="text-align: right;" | 25.76 Bbl
| Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-031-27177
+
| 34-119-28803
| ADAMS #1 (SWIW #10)
 
| COSHOCTON
 
| OH
 
 
|-
 
|-
 +
| 2016-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 474.16 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2012-2
+
| 2016-06
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 37.0
+
| style="text-align: right;" | 86.40 Bbl
| Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-013-20609
 
| 34-013-20609
| BUCKEYE UIC BARNESVILLE #1 (SWIW#2)
 
| BARNESVILLE
 
| OH
 
 
|-
 
|-
 +
| 2016-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 42.84 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 +
|-
 +
| 2016-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 331.35 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2016-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 471.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2012-2
+
| 2016-08
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 586.0
+
| style="text-align: right;" | 445.00 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR HYDRAULIC FRACTURING
+
|-
 +
| 2016-09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 417.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2016-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 77.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-013-20609
 +
|-
 +
| 2016-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28780
 +
|-
 +
| 2016-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 163.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 +
|-
 +
| 2016-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 144.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
 +
| 2016-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 26.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-013-20609
 
|-
 
|-
| 2012-2
+
| 2016-11
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 65.0
+
| style="text-align: right;" | 84.00 Bbl
| Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-121-23995
+
| 34-119-28803
| WARREN DRILLING CO #1 (SWIW #6)
 
| DEXTER CITY
 
| OH
 
 
|-
 
|-
 +
| 2016-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 316.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2013-1
+
| 2016-12
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 757.48
+
| style="text-align: right;" | 386.00 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR HYDRAULIC FRACTURING
+
|-
 +
| 2017-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 62.86 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 267.14 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-10
 +
|-
 +
| 2017-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 86.43 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2017-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.71 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-10
 +
|-
 +
| 2017-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 141.43 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 +
|-
 +
| 2017-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 77.86 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-21
 +
|-
 +
| 2017-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 63.57 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 129.80 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-16
 +
|-
 +
| 2017-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 86.43 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-17
 +
|-
 +
| 2017-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 32.46 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-21
 +
|-
 +
| 2017-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.71 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 286.29 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-10
 +
|-
 +
| 2017-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 351.29 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-10
 +
|-
 +
| 2017-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 22.14 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 211.29 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-10
 +
|-
 +
| 2017-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.71 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 +
|-
 +
| 2017-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 107.86 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-21
 +
|-
 +
| 2017-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 197.14 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-17
 +
|-
 +
| 2017-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 60.29 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 +
|-
 +
| 2017-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 47.14 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-21
 +
|-
 +
| 2017-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 109.57 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-013-20609
 +
|-
 +
| 2017-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 12.86 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28780
 
|-
 
|-
| 2013-2
+
| 2017-08
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 9.68
+
| style="text-align: right;" | 79.71 Bbl
| Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-031-27177
+
| 34-119-28803
| ADAMS #1 (SWIW #10)
+
|-
| COSHOCTON
+
| 2017-08
| OH
+
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 31.43 Bbl
 +
| REUSE (AT WELL PAD)
 +
|  
 
|-
 
|-
 +
| 2017-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 17.00 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 
|-
 
|-
| 2013-2
+
| 2017-09
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 13.61
+
| style="text-align: right;" | 30.41 Bbl
| Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-013-20609
 
| 34-013-20609
| BUCKEYE UIC BARNESVILLE #1 (SWIW#2)
 
| BARNESVILLE
 
| OH
 
 
|-
 
|-
 +
| 2017-09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 17.49 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28780
 
|-
 
|-
| 2013-2
+
| 2017-09
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 0.5
+
| style="text-align: right;" | 46.33 Bbl
| Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-119-28776
+
| 34-119-28803
| GOFF #1 (SWIW #27)
+
|-
| NORWICH
+
| 2017-09
| OH
+
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 60.34 Bbl
 +
| REUSE (AT WELL PAD)
 +
|  
 
|-
 
|-
 +
| 2017-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 36.14 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 
|-
 
|-
| 2013-2
+
| 2017-10
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 473.08
+
| style="text-align: right;" | 31.43 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2017-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 31.43 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 +
|-
 +
| 2017-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 93.84 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 +
|-
 +
| 2017-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 125.71 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 103.99 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-21
 +
|-
 +
| 2017-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 87.77 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-2-3794
 +
|-
 +
| 2017-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.71 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2017-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 35.27 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-17
 
|-
 
|-
| 2013-2
+
| 2017-12
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 5.3
+
| style="text-align: right;" | 102.24 Bbl
| Bbl
+
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 +
|-
 +
| 2017-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 16.46 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-21
 +
|-
 +
| 2018-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 200.14 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-059-24202
+
| 34-119-28803
| SOS-D #1 (SWIW #12)
+
|-
| CAMBRIDGE
+
| 2018-01
| OH
+
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 31.43 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-17
 +
|-
 +
| 2018-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 59.71 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 
|-
 
|-
 +
| 2018-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 21.43 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28780
 
|-
 
|-
| 2013-2
+
| 2018-02
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 37.88
+
| style="text-align: right;" | 219.54 Bbl
| Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-105-23619
+
| 34-119-28803
| SWIW #19
+
|-
| MEIGS
+
| 2018-02
| OH
+
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 23.57 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 40.71 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 +
|-
 +
| 2018-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.71 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 187.18 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 +
|-
 +
| 2018-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 31.43 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-21
 +
|-
 +
| 2018-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 31.43 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 47.14 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-17
 
|-
 
|-
 +
| 2018-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 77.57 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 
|-
 
|-
| 2014-1
+
| 2018-05
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 11.39
+
| style="text-align: right;" | 94.29 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| INJECTION DISPOSAL WELL
+
|  
| 34-013-20609
+
|-
| BUCKEYE UIC BARNESVILLE #1 (SWIW#2)
+
| 2018-05
| BARNESVILLE
+
| Produced Fluid (in Barrels) RWC 802
| OH
+
| style="text-align: right;" | 81.86 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 
|-
 
|-
 +
| 2018-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 90.00 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-21
 
|-
 
|-
| 2014-1
+
| 2018-06
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 2.48
+
| style="text-align: right;" | 15.71 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| INJECTION DISPOSAL WELL
+
|  
| 34-119-28776
+
|-
| GOFF #1 (SWIW #27)
+
| 2018-06
| NORWICH
+
| Produced Fluid (in Barrels) RWC 802
| OH
+
| style="text-align: right;" | 174.29 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 
|-
 
|-
 +
| 2018-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 33.43 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-21
 
|-
 
|-
| 2014-1
+
| 2018-07
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 20.79
+
| style="text-align: right;" | 15.71 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| STORAGE PENDING DISPOSAL OR REUSE
 
 
|  
 
|  
| HUNTER DISPOSAL - NEW MATAMORAS
 
| NEW MATAMORAS
 
| OH
 
 
|-
 
|-
 +
| 2018-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.71 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-17
 +
|-
 +
| 2018-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 180.00 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 +
|-
 +
| 2018-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 47.14 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-21
 +
|-
 +
| 2018-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 200.00 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 +
|-
 +
| 2018-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.71 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-21
 
|-
 
|-
| 2014-1
+
| 2018-09
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 2.48
+
| style="text-align: right;" | 234.29 Bbl
| Bbl
+
| SURFACE IMPOUNDMENT
| INJECTION DISPOSAL WELL
+
| 95-7-37312-19
| 2D0859721
+
|-
| MASON WELL #1 (47-085-09721)
+
| 2018-09
| ELLENBORO
+
| Produced Fluid (in Barrels) RWC 802
| WV
+
| style="text-align: right;" | 15.71 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-21
 
|-
 
|-
 +
| 2018-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.71 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2014-1
+
| 2018-10
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 285.85
+
| style="text-align: right;" | 14.29 Bbl
| Bbl
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2018-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.71 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-17
 +
|-
 +
| 2018-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 147.48 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 +
|-
 +
| 2018-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.71 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-21
 +
|-
 +
| 2018-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 164.87 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 +
|-
 +
| 2018-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 60.57 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 +
|-
 +
| 2018-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 207.14 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 +
|-
 +
| 2019-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 55.00 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 
|-
 
|-
 +
| 2019-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 166.43 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 
|-
 
|-
| 2014-1
+
| 2019-02
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 9.41
+
| style="text-align: right;" | 12.14 Bbl
| Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-059-24202
+
| 34-119-28780
| SOS-D #1 (SWIW #12)
 
| CAMBRIDGE
 
| OH
 
 
|-
 
|-
 +
| 2019-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.29 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 
|-
 
|-
| 2014-1
+
| 2019-02
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 2.97
+
| style="text-align: right;" | 15.71 Bbl
| Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-121-23995
+
| 34-157-25511
| WARREN DRILLING CO #1 (SWIW #6)
 
| DEXTER CITY
 
| OH
 
 
|-
 
|-
 +
| 2019-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 47.14 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2014-2
+
| 2019-02
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 57.5
+
| style="text-align: right;" | 44.29 Bbl
| Bbl
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
| REUSE OTHER THAN ROAD SPREADING
 
|
 
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
 
 
|  
 
|  
 +
|-
 +
| 2019-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 42.14 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-17
 +
|-
 +
| 2019-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 31.43 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW005
 +
|-
 +
| 2019-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 31.43 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2019-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 92.86 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-19
 +
|-
 +
| 2019-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.71 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-7-37312-21
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Waste Report
+
  | title =Oil and Gas Waste Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-26 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Inspection ID
!scope="col" | DATE
+
!scope="col" | Inspection Category
!scope="col" | DESCRIPTION
+
!scope="col" | Inspection Date
!scope="col" | COMMENT
+
!scope="col" | Inspection Type
!scope="col" | VIOLATION ID
+
!scope="col" | Inspection Result
!scope="col" | VIOLATION CODE
+
!scope="col" | Inspection Comments
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
 
| 2006639
 
| 2006639
| 2011-09-28
+
| Primary Facility
 +
| 09/28/2011
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| Well is top-holed; waiting onhoriz. drilling; E&S good
 
| Well is top-holed; waiting onhoriz. drilling; E&S good
 +
|-
 +
| 2052129
 +
| Primary Facility
 +
| 02/15/2012
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| The Department was at the above referenced Marcellus Well to conduct a Routine Inspection.  The wells have been drilled and just recently fracked.  The pits are still open on site.  The site appears to be in good condition.  The E/S Controls are in place and appear to be in good working condition.
 +
|-
 +
| 2166701
 +
| Primary Facility
 +
| 04/25/2013
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| On April 25, 2013, I stopped at CONSOL’s NV-48 pad for a routine inspection.  The site is in production and CONSOL has started to reclaim the site.  I checked the following areas:
 +
|-
 +
| 2273561
 +
| Primary Facility
 +
| 05/06/2014
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| ROUTINE INSPECTION. PRODUCING WELL. PRODUCTION UNIT AND TANK IN PLACE.
 +
|-
 +
| 2303880
 +
| Primary Facility
 +
| 09/12/2014
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 +
|-
 +
| 2530884
 +
| Primary Facility
 +
| 2016-10-07
 +
| Site Restoration
 +
| No Violations Noted
 +
| A site restoration inspection conducted in response to an operator submittal of a notice of termination for an ESCGP.
 +
|-
 +
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
|}-->
 +
<!--==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 12/05/2011
 +
| 12/05/2011
 +
| style="text-align: right;" | 7860.00
 +
| style="text-align: right;" | 2,888,250.0
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="23"| 1
 +
| rowspan="1"| DWP-938
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Surfactant
 +
| Soap
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 0.06
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="6"| DAP-901
 +
| rowspan="6"| Calfrac Well Services
 +
| rowspan="6"| Scale Inhibitor
 +
| Oxyalkylated Polyamine
 +
|
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00070000
 +
| style="text-align: right;" |
 +
|-
 +
| Amine Salt
 
|  
 
|  
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00070000
 +
| style="text-align: right;" |
 +
|-
 +
| Methanol
 +
| 67-56-1
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00419000
 +
| style="text-align: right;" |
 +
|-
 +
| Phosphoric Acid Ammonium Salt
 
|  
 
|  
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00070000
 +
| style="text-align: right;" |
 +
|-
 +
| Ammonium chloride
 +
| 12125-02-9
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00140000
 +
| style="text-align: right;" |
 +
|-
 +
| Organic Phosphonate
 
|  
 
|  
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00419000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="7"| DAP-923
 +
| rowspan="7"| Calfrac Well Services
 +
| rowspan="7"| Corrosion Inhibitor
 +
| Thiourea polymer
 +
| 68527-49-1
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00014000
 +
| style="text-align: right;" |
 +
|-
 +
| Methanol
 +
| 67-56-1
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.00028000
 +
| style="text-align: right;" |
 
|-
 
|-
 +
| Fatty Acids
 +
|
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00014000
 +
| style="text-align: right;" |
 
|-
 
|-
| 2052129
+
| Polyoxyalkylenes
| 2012-02-15
 
| No Violations Noted
 
| The Department was at the above referenced Marcellus Well to conduct a Routine Inspection.  The wells have been drilled and just recently fracked.  The pits are still open on site.  The site appears to be in good condition.  The E/S Controls are in place and appear to be in good working condition.
 
 
|  
 
|  
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00014000
 +
| style="text-align: right;" |
 +
|-
 
|  
 
|  
 
|  
 
|  
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 
|-
 
|-
 +
| Olefin
 +
|
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00002000
 +
| style="text-align: right;" |
 
|-
 
|-
| 2166701
+
| Propargyl alcohol
| 2013-04-25
+
| 107-19-7
| No Violations Noted
+
| style="text-align: right;" | 10.00
| On April 25, 2013, I stopped at CONSOLï¾’s NV-48 pad for a routine inspection. The site is in production and CONSOL has started to reclaim the site.  I checked the following areas:
+
| style="text-align: right;" | 0.00005000
 
+
| style="text-align: right;" |
NV-48 pad ESX10-059-0062, Site 738130
+
|-
NV-48-DHS,  059-25666
+
|- valign="top"
NV-48-BHS,    059-25614
+
| rowspan="1"| DWP-612
NV-48-AHS    059-25634
+
| rowspan="1"| Calfrac Well Services
NV-48-EHS      059-25678
+
| rowspan="1"| Friction Reduction
 
+
| Long Chain Polyacrylamide
An additional well, NV-48-CHS was permitted for this site on December 27, 2010 but it was never spudded.
 
 
 
There was an Act 9 sign at the Barker Road entrance.  In the mailbox I found both an E&S plan and a PPC plan.
 
 
 
As stated, CONSOL is reclaiming the site.  Thus they removed the sediment traps and the perimeter E&S controls, re-graded and are working on re-vegetation, but they arenï¾’t ready for a formal N.O.T. yet. 
 
 
 
I found no violations, but CONSOL needs to finish the work, watch erosion issues and inspect the site weekly and after precipitation events.
 
 
 
 
|  
 
|  
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 0.14
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| Hydrochloric Acid
 +
| rowspan="2"| Calfrac Well Services
 +
| rowspan="2"| Acid
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.93
 +
| style="text-align: right;" |
 +
|-
 
|  
 
|  
 
|  
 
|  
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="2"| DWP-944
 +
| rowspan="2"| Calfrac Well Services
 +
| rowspan="2"| Biocide
 +
| Polyethylene glycol
 +
| 25322-68-3
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.00619000
 +
| style="text-align: right;" |
 
|-
 
|-
| 2303880
+
| 2,2-Dibromo-3-nitrilopropionamide
| 2014-09-12
+
| 10222-01-2
| No Violations Noted
+
| style="text-align: right;" | 20.00
 +
| style="text-align: right;" | 0.00206000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Sand
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Proppant
 +
| Sand
 
|  
 
|  
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 5.58
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Water
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Carrier
 +
| Water
 
|  
 
|  
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 93.23
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| DWP-690
 +
| rowspan="2"| Calfrac Well Services
 +
| rowspan="2"| Friction Reducer Breaker
 
|  
 
|  
 
|  
 
|  
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Hydrogen peroxide
 +
| 7722-84-1
 +
| style="text-align: right;" | 7.00
 +
| style="text-align: right;" | 0.00069000
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Inspection Report
+
  | title =FracFocus Fracking Chemicals Database
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| date = 2019-04-02
| date = 2015-05-26
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
+
  | accessdate = 2019-06-19 }}</ref>
  | accessdate = 2015-05-27 }}</ref>
+
==References==
== References ==
+
<references/>
{{reflist}}
 
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Revision as of 15:19, 13 July 2019

Well Details

Well ID: 37-059-25678
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Morris Township
Operator Name: CNX GAS CO LLC
Well Pad ID: 148914
Farm/Lease Name: MOONEY NV48EHS
License Status: Active
Spud Date: 06/04/2011
Permit Date: 2/25/2011
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 39.997267
Longitude: -80.301394

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0
2011 CNX GAS CO LLC 6,176.67 3 0.00 0 0.00 0
2012 CNX GAS CO LLC 684,266.94 366 0.00 0 0.00 0
2013 CNX GAS CO LLC 253,525.18 365 0.00 0 0.00 0
2014 CNX GAS CO LLC 320,994.59 365 0.00 0 0.00 0
2015 CNX GAS CO LLC 293,181.35 365 0.00 0 0.00 0
2016 CNX GAS CO LLC 239,473.33 366 0.00 0 0.00 0
2017 CNX GAS CO LLC 261,168.92 365 0.00 0 0.00 0
2018 CNX GAS CO LLC 176,519.95 365 0.00 0 0.00 0
2019 CNX GAS CO LLC 29,529.38 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
15AUGU Produced Fluid (in Barrels) 907.62 Bbl REUSE OTHER THAN ROAD SPREADING
15DECU Produced Fluid (in Barrels) 694.64 Bbl REUSE OTHER THAN ROAD SPREADING
15JULU Produced Fluid (in Barrels) 1,192.85 Bbl REUSE OTHER THAN ROAD SPREADING
15NOVU Produced Fluid (in Barrels) 742.28 Bbl REUSE OTHER THAN ROAD SPREADING
15OCTU Produced Fluid (in Barrels) 779.35 Bbl REUSE OTHER THAN ROAD SPREADING
15SEPU Produced Fluid (in Barrels) 832.00 Bbl REUSE OTHER THAN ROAD SPREADING
16APRU Produced Fluid (in Barrels) RWC 802 505.94 Bbl REUSE OTHER THAN ROAD SPREADING
16AUGU Produced Fluid (in Barrels) RWC 802 445.00 Bbl REUSE OTHER THAN ROAD SPREADING
16DECU Produced Fluid (in Barrels) RWC 802 386.00 Bbl REUSE OTHER THAN ROAD SPREADING
16FEBU Produced Fluid (in Barrels) RWC 802 455.67 Bbl REUSE OTHER THAN ROAD SPREADING
16JANU Produced Fluid (in Barrels) RWC 802 712.29 Bbl REUSE OTHER THAN ROAD SPREADING
16JULU Produced Fluid (in Barrels) RWC 802 471.00 Bbl REUSE OTHER THAN ROAD SPREADING
16JUNU Produced Fluid (in Barrels) RWC 802 86.40 Bbl INJECTION DISPOSAL WELL 34-013-20609
16JUNU Produced Fluid (in Barrels) RWC 802 42.84 Bbl INJECTION DISPOSAL WELL 34-119-28803
16JUNU Produced Fluid (in Barrels) RWC 802 331.35 Bbl REUSE OTHER THAN ROAD SPREADING
16MARU Produced Fluid (in Barrels) RWC 802 628.64 Bbl REUSE OTHER THAN ROAD SPREADING
16MAYU Produced Fluid (in Barrels) RWC 802 17.14 Bbl INJECTION DISPOSAL WELL 34-013-20609
16MAYU Produced Fluid (in Barrels) RWC 802 25.76 Bbl INJECTION DISPOSAL WELL 34-119-28803
16MAYU Produced Fluid (in Barrels) RWC 802 474.16 Bbl REUSE OTHER THAN ROAD SPREADING
16NOVU Produced Fluid (in Barrels) RWC 802 26.00 Bbl INJECTION DISPOSAL WELL 34-013-20609
16NOVU Produced Fluid (in Barrels) RWC 802 84.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
16NOVU Produced Fluid (in Barrels) RWC 802 316.00 Bbl REUSE OTHER THAN ROAD SPREADING
16OCTU Produced Fluid (in Barrels) RWC 802 77.00 Bbl INJECTION DISPOSAL WELL 34-013-20609
16OCTU Produced Fluid (in Barrels) RWC 802 13.00 Bbl INJECTION DISPOSAL WELL 34-119-28780
16OCTU Produced Fluid (in Barrels) RWC 802 163.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
16OCTU Produced Fluid (in Barrels) RWC 802 144.00 Bbl REUSE OTHER THAN ROAD SPREADING
16SEPU Produced Fluid (in Barrels) RWC 802 417.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011-2 Produced Fluid (in Barrels) 345.43 Bbl REUSE OTHER THAN ROAD SPREADING
2012-1 Produced Fluid (in Barrels) 49.59 Bbl LANDFILL 100277
2012-1 Produced Fluid (in Barrels) 2,832.01 Bbl REUSE OTHER THAN ROAD SPREADING
2012-2 Produced Fluid (in Barrels) 37.00 Bbl INJECTION DISPOSAL WELL 34-013-20609
2012-2 Produced Fluid (in Barrels) 27.00 Bbl INJECTION DISPOSAL WELL 34-031-27177
2012-2 Produced Fluid (in Barrels) 65.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2012-2 Produced Fluid (in Barrels) 586.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-1 Produced Fluid (in Barrels) 757.48 Bbl REUSE OTHER THAN ROAD SPREADING
2013-2 Produced Fluid (in Barrels) 13.61 Bbl INJECTION DISPOSAL WELL 34-013-20609
2013-2 Produced Fluid (in Barrels) 9.68 Bbl INJECTION DISPOSAL WELL 34-031-27177
2013-2 Produced Fluid (in Barrels) 5.30 Bbl INJECTION DISPOSAL WELL 34-059-24202
2013-2 Produced Fluid (in Barrels) 37.88 Bbl INJECTION DISPOSAL WELL 34-105-23619
2013-2 Produced Fluid (in Barrels) 0.50 Bbl INJECTION DISPOSAL WELL 34-119-28776
2013-2 Produced Fluid (in Barrels) 473.08 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Produced Fluid (in Barrels) 2.48 Bbl INJECTION DISPOSAL WELL 2D0859721
2014-1 Produced Fluid (in Barrels) 11.39 Bbl INJECTION DISPOSAL WELL 34-013-20609
2014-1 Produced Fluid (in Barrels) 9.41 Bbl INJECTION DISPOSAL WELL 34-059-24202
2014-1 Produced Fluid (in Barrels) 2.48 Bbl INJECTION DISPOSAL WELL 34-119-28776
2014-1 Produced Fluid (in Barrels) 2.97 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014-1 Produced Fluid (in Barrels) 285.85 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Produced Fluid (in Barrels) 20.79 Bbl STORAGE PENDING DISPOSAL OR REUSE
2014-2 Produced Fluid (in Barrels) 57.50 Bbl REUSE OTHER THAN ROAD SPREADING
2015-07 Produced Fluid (in Barrels) 1,192.85 Bbl REUSE OTHER THAN ROAD SPREADING
2015-08 Produced Fluid (in Barrels) 907.62 Bbl REUSE OTHER THAN ROAD SPREADING
2015-09 Produced Fluid (in Barrels) 832.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Produced Fluid (in Barrels) 12,919.72 Bbl REUSE OTHER THAN ROAD SPREADING
2015-10 Produced Fluid (in Barrels) 779.35 Bbl REUSE OTHER THAN ROAD SPREADING
2015-11 Produced Fluid (in Barrels) 742.28 Bbl REUSE OTHER THAN ROAD SPREADING
2015-12 Produced Fluid (in Barrels) 694.64 Bbl REUSE OTHER THAN ROAD SPREADING
2016-01 Produced Fluid (in Barrels) RWC 802 712.29 Bbl REUSE OTHER THAN ROAD SPREADING
2016-02 Produced Fluid (in Barrels) RWC 802 455.67 Bbl REUSE OTHER THAN ROAD SPREADING
2016-03 Produced Fluid (in Barrels) RWC 802 628.64 Bbl REUSE OTHER THAN ROAD SPREADING
2016-04 Produced Fluid (in Barrels) RWC 802 505.94 Bbl REUSE OTHER THAN ROAD SPREADING
2016-05 Produced Fluid (in Barrels) RWC 802 17.14 Bbl INJECTION DISPOSAL WELL 34-013-20609
2016-05 Produced Fluid (in Barrels) RWC 802 25.76 Bbl INJECTION DISPOSAL WELL 34-119-28803
2016-05 Produced Fluid (in Barrels) RWC 802 474.16 Bbl REUSE OTHER THAN ROAD SPREADING
2016-06 Produced Fluid (in Barrels) RWC 802 86.40 Bbl INJECTION DISPOSAL WELL 34-013-20609
2016-06 Produced Fluid (in Barrels) RWC 802 42.84 Bbl INJECTION DISPOSAL WELL 34-119-28803
2016-06 Produced Fluid (in Barrels) RWC 802 331.35 Bbl REUSE OTHER THAN ROAD SPREADING
2016-07 Produced Fluid (in Barrels) RWC 802 471.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-08 Produced Fluid (in Barrels) RWC 802 445.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-09 Produced Fluid (in Barrels) RWC 802 417.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-10 Produced Fluid (in Barrels) RWC 802 77.00 Bbl INJECTION DISPOSAL WELL 34-013-20609
2016-10 Produced Fluid (in Barrels) RWC 802 13.00 Bbl INJECTION DISPOSAL WELL 34-119-28780
2016-10 Produced Fluid (in Barrels) RWC 802 163.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2016-10 Produced Fluid (in Barrels) RWC 802 144.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-11 Produced Fluid (in Barrels) RWC 802 26.00 Bbl INJECTION DISPOSAL WELL 34-013-20609
2016-11 Produced Fluid (in Barrels) RWC 802 84.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2016-11 Produced Fluid (in Barrels) RWC 802 316.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-12 Produced Fluid (in Barrels) RWC 802 386.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017-01 Produced Fluid (in Barrels) RWC 802 62.86 Bbl REUSE (AT WELL PAD)
2017-01 Produced Fluid (in Barrels) RWC 802 267.14 Bbl SURFACE IMPOUNDMENT 95-7-37312-10
2017-02 Produced Fluid (in Barrels) RWC 802 86.43 Bbl REUSE (AT WELL PAD)
2017-02 Produced Fluid (in Barrels) RWC 802 15.71 Bbl SURFACE IMPOUNDMENT 95-7-37312-10
2017-02 Produced Fluid (in Barrels) RWC 802 141.43 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2017-02 Produced Fluid (in Barrels) RWC 802 77.86 Bbl SURFACE IMPOUNDMENT 95-7-37312-21
2017-03 Produced Fluid (in Barrels) RWC 802 63.57 Bbl REUSE (AT WELL PAD)
2017-03 Produced Fluid (in Barrels) RWC 802 129.80 Bbl SURFACE IMPOUNDMENT 95-7-37312-16
2017-03 Produced Fluid (in Barrels) RWC 802 86.43 Bbl SURFACE IMPOUNDMENT 95-7-37312-17
2017-03 Produced Fluid (in Barrels) RWC 802 32.46 Bbl SURFACE IMPOUNDMENT 95-7-37312-21
2017-04 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE (AT WELL PAD)
2017-04 Produced Fluid (in Barrels) RWC 802 286.29 Bbl SURFACE IMPOUNDMENT 95-7-37312-10
2017-05 Produced Fluid (in Barrels) RWC 802 351.29 Bbl SURFACE IMPOUNDMENT 95-7-37312-10
2017-06 Produced Fluid (in Barrels) RWC 802 22.14 Bbl REUSE (AT WELL PAD)
2017-06 Produced Fluid (in Barrels) RWC 802 211.29 Bbl SURFACE IMPOUNDMENT 95-7-37312-10
2017-06 Produced Fluid (in Barrels) RWC 802 15.71 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2017-06 Produced Fluid (in Barrels) RWC 802 107.86 Bbl SURFACE IMPOUNDMENT 95-7-37312-21
2017-07 Produced Fluid (in Barrels) RWC 802 197.14 Bbl SURFACE IMPOUNDMENT 95-7-37312-17
2017-07 Produced Fluid (in Barrels) RWC 802 60.29 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2017-07 Produced Fluid (in Barrels) RWC 802 47.14 Bbl SURFACE IMPOUNDMENT 95-7-37312-21
2017-08 Produced Fluid (in Barrels) RWC 802 109.57 Bbl INJECTION DISPOSAL WELL 34-013-20609
2017-08 Produced Fluid (in Barrels) RWC 802 12.86 Bbl INJECTION DISPOSAL WELL 34-119-28780
2017-08 Produced Fluid (in Barrels) RWC 802 79.71 Bbl INJECTION DISPOSAL WELL 34-119-28803
2017-08 Produced Fluid (in Barrels) RWC 802 31.43 Bbl REUSE (AT WELL PAD)
2017-08 Produced Fluid (in Barrels) RWC 802 17.00 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2017-09 Produced Fluid (in Barrels) RWC 802 30.41 Bbl INJECTION DISPOSAL WELL 34-013-20609
2017-09 Produced Fluid (in Barrels) RWC 802 17.49 Bbl INJECTION DISPOSAL WELL 34-119-28780
2017-09 Produced Fluid (in Barrels) RWC 802 46.33 Bbl INJECTION DISPOSAL WELL 34-119-28803
2017-09 Produced Fluid (in Barrels) RWC 802 60.34 Bbl REUSE (AT WELL PAD)
2017-10 Produced Fluid (in Barrels) RWC 802 36.14 Bbl INJECTION DISPOSAL WELL 34-119-28803
2017-10 Produced Fluid (in Barrels) RWC 802 31.43 Bbl REUSE (AT WELL PAD)
2017-10 Produced Fluid (in Barrels) RWC 802 31.43 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2017-11 Produced Fluid (in Barrels) RWC 802 93.84 Bbl INJECTION DISPOSAL WELL 34-119-28803
2017-11 Produced Fluid (in Barrels) RWC 802 125.71 Bbl REUSE (AT WELL PAD)
2017-11 Produced Fluid (in Barrels) RWC 802 103.99 Bbl SURFACE IMPOUNDMENT 95-7-37312-21
2017-12 Produced Fluid (in Barrels) RWC 802 87.77 Bbl INJECTION DISPOSAL WELL 34-155-2-3794
2017-12 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE (AT WELL PAD)
2017-12 Produced Fluid (in Barrels) RWC 802 35.27 Bbl SURFACE IMPOUNDMENT 95-7-37312-17
2017-12 Produced Fluid (in Barrels) RWC 802 102.24 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2017-12 Produced Fluid (in Barrels) RWC 802 16.46 Bbl SURFACE IMPOUNDMENT 95-7-37312-21
2018-01 Produced Fluid (in Barrels) RWC 802 200.14 Bbl INJECTION DISPOSAL WELL 34-119-28803
2018-01 Produced Fluid (in Barrels) RWC 802 31.43 Bbl SURFACE IMPOUNDMENT 95-7-37312-17
2018-01 Produced Fluid (in Barrels) RWC 802 59.71 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-02 Produced Fluid (in Barrels) RWC 802 21.43 Bbl INJECTION DISPOSAL WELL 34-119-28780
2018-02 Produced Fluid (in Barrels) RWC 802 219.54 Bbl INJECTION DISPOSAL WELL 34-119-28803
2018-02 Produced Fluid (in Barrels) RWC 802 23.57 Bbl REUSE (AT WELL PAD)
2018-02 Produced Fluid (in Barrels) RWC 802 40.71 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-03 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE (AT WELL PAD)
2018-03 Produced Fluid (in Barrels) RWC 802 187.18 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-03 Produced Fluid (in Barrels) RWC 802 31.43 Bbl SURFACE IMPOUNDMENT 95-7-37312-21
2018-04 Produced Fluid (in Barrels) RWC 802 31.43 Bbl REUSE (AT WELL PAD)
2018-04 Produced Fluid (in Barrels) RWC 802 47.14 Bbl SURFACE IMPOUNDMENT 95-7-37312-17
2018-04 Produced Fluid (in Barrels) RWC 802 77.57 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-05 Produced Fluid (in Barrels) RWC 802 94.29 Bbl REUSE (AT WELL PAD)
2018-05 Produced Fluid (in Barrels) RWC 802 81.86 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-05 Produced Fluid (in Barrels) RWC 802 90.00 Bbl SURFACE IMPOUNDMENT 95-7-37312-21
2018-06 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE (AT WELL PAD)
2018-06 Produced Fluid (in Barrels) RWC 802 174.29 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-06 Produced Fluid (in Barrels) RWC 802 33.43 Bbl SURFACE IMPOUNDMENT 95-7-37312-21
2018-07 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE (AT WELL PAD)
2018-07 Produced Fluid (in Barrels) RWC 802 15.71 Bbl SURFACE IMPOUNDMENT 95-7-37312-17
2018-07 Produced Fluid (in Barrels) RWC 802 180.00 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-07 Produced Fluid (in Barrels) RWC 802 47.14 Bbl SURFACE IMPOUNDMENT 95-7-37312-21
2018-08 Produced Fluid (in Barrels) RWC 802 200.00 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-08 Produced Fluid (in Barrels) RWC 802 15.71 Bbl SURFACE IMPOUNDMENT 95-7-37312-21
2018-09 Produced Fluid (in Barrels) RWC 802 234.29 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-09 Produced Fluid (in Barrels) RWC 802 15.71 Bbl SURFACE IMPOUNDMENT 95-7-37312-21
2018-10 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE (AT WELL PAD)
2018-10 Produced Fluid (in Barrels) RWC 802 14.29 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-10 Produced Fluid (in Barrels) RWC 802 15.71 Bbl SURFACE IMPOUNDMENT 95-7-37312-17
2018-10 Produced Fluid (in Barrels) RWC 802 147.48 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-10 Produced Fluid (in Barrels) RWC 802 15.71 Bbl SURFACE IMPOUNDMENT 95-7-37312-21
2018-11 Produced Fluid (in Barrels) RWC 802 164.87 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2018-12 Produced Fluid (in Barrels) RWC 802 60.57 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-12 Produced Fluid (in Barrels) RWC 802 207.14 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019-01 Produced Fluid (in Barrels) RWC 802 55.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-01 Produced Fluid (in Barrels) RWC 802 166.43 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019-02 Produced Fluid (in Barrels) RWC 802 12.14 Bbl INJECTION DISPOSAL WELL 34-119-28780
2019-02 Produced Fluid (in Barrels) RWC 802 13.29 Bbl INJECTION DISPOSAL WELL 34-119-28803
2019-02 Produced Fluid (in Barrels) RWC 802 15.71 Bbl INJECTION DISPOSAL WELL 34-157-25511
2019-02 Produced Fluid (in Barrels) RWC 802 47.14 Bbl REUSE (AT WELL PAD)
2019-02 Produced Fluid (in Barrels) RWC 802 44.29 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-02 Produced Fluid (in Barrels) RWC 802 42.14 Bbl SURFACE IMPOUNDMENT 95-7-37312-17
2019-03 Produced Fluid (in Barrels) RWC 802 31.43 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019-03 Produced Fluid (in Barrels) RWC 802 31.43 Bbl REUSE (AT WELL PAD)
2019-03 Produced Fluid (in Barrels) RWC 802 92.86 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019-03 Produced Fluid (in Barrels) RWC 802 15.71 Bbl SURFACE IMPOUNDMENT 95-7-37312-21

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2006639 Primary Facility 09/28/2011 Drilling/Alteration No Violations Noted Well is top-holed; waiting onhoriz. drilling; E&S good
2052129 Primary Facility 02/15/2012 Routine/Complete Inspection No Violations Noted The Department was at the above referenced Marcellus Well to conduct a Routine Inspection. The wells have been drilled and just recently fracked. The pits are still open on site. The site appears to be in good condition. The E/S Controls are in place and appear to be in good working condition.
2166701 Primary Facility 04/25/2013 Routine/Complete Inspection No Violations Noted On April 25, 2013, I stopped at CONSOL’s NV-48 pad for a routine inspection. The site is in production and CONSOL has started to reclaim the site. I checked the following areas:
2273561 Primary Facility 05/06/2014 Routine/Complete Inspection No Violations Noted ROUTINE INSPECTION. PRODUCING WELL. PRODUCTION UNIT AND TANK IN PLACE.
2303880 Primary Facility 09/12/2014 Routine/Complete Inspection No Violations Noted
2530884 Primary Facility 2016-10-07 Site Restoration No Violations Noted A site restoration inspection conducted in response to an operator submittal of a notice of termination for an ESCGP.

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 12/05/2011 12/05/2011 7860.00 2,888,250.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 DWP-938 Calfrac Well Services Surfactant Soap 0.06
DAP-901 Calfrac Well Services Scale Inhibitor Oxyalkylated Polyamine 5.00 0.00070000
Amine Salt 5.00 0.00070000
Methanol 67-56-1 30.00 0.00419000
Phosphoric Acid Ammonium Salt 5.00 0.00070000
Ammonium chloride 12125-02-9 10.00 0.00140000
Organic Phosphonate 30.00 0.00419000
DAP-923 Calfrac Well Services Corrosion Inhibitor Thiourea polymer 68527-49-1 30.00 0.00014000
Methanol 67-56-1 60.00 0.00028000
Fatty Acids 30.00 0.00014000
Polyoxyalkylenes 30.00 0.00014000
Olefin 5.00 0.00002000
Propargyl alcohol 107-19-7 10.00 0.00005000
DWP-612 Calfrac Well Services Friction Reduction Long Chain Polyacrylamide 0.14
Hydrochloric Acid Calfrac Well Services Acid Hydrochloric acid 7647-01-0 5.00 0.93
DWP-944 Calfrac Well Services Biocide Polyethylene glycol 25322-68-3 60.00 0.00619000
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.00206000
Sand Calfrac Well Services Proppant Sand 100.00 5.58
Water Calfrac Well Services Carrier Water 100.00 93.23
DWP-690 Calfrac Well Services Friction Reducer Breaker
Hydrogen peroxide 7722-84-1 7.00 0.00069000

For data sources see[7]

References