| Well ID: 37-015-20422
 
| Well ID: 37-015-20422
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.786655, -76.230807 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="14" | {{#display_map: 41.786656, -76.230808 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Bradford County, Pennsylvania|Bradford]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Herrick Township, Bradford County, Pennsylvania|Herrick Township]]
+
| State: Pennsylvania
 
|-
 
|-
| Operator Name: [[SOUTHWESTERN ENERGY PROD CO]]
+
| County: [[Bradford_County,_Pennsylvania|Bradford]]
 
|-
 
|-
| Well Pad ID: [[148443|148443]]
+
| Municipality: [[Herrick Township,_Bradford_County,_Pennsylvania|Herrick Township]]
 +
|-
 +
| Operator Name: [[SWN PROD CO LLC]]
 +
|-
 +
| Well Pad ID: [[153757]]
 
|-
 
|-
 
| Farm/Lease Name: GREENZWEIG 3H
 
| Farm/Lease Name: GREENZWEIG 3H
 
|-
 
|-
| First Permit Date: 2009-09-02
+
| License Status: Active
 +
|-
 +
| Spud Date: 05/23/2010
 +
|-
 +
| Permit Date: 9/2/2009
 +
|-
 +
| Unconventional Well: Y
 +
|-
 +
| Configuration: Horizontal Well
 +
|-
 +
| Latitude: 41.786656
 +
|-
 +
| Longitude: -76.230808
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator Name
 +
!scope="col" | Gas Quantity (mcf)
 +
!scope="col" | Gas Production Days
 +
!scope="col" | Oil Quantity (bbl)
 +
!scope="col" | Oil Production Days
 +
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 +
|-
 +
| 2009
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" |
 +
|-
 +
| 2010
 +
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2011
 +
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| style="text-align: right;" | 210,660.00
 +
| style="text-align: right;" | 42
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Last Permit Date: 2010-08-24
+
| 2012
 +
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| style="text-align: right;" | 1,614,487.00
 +
| style="text-align: right;" | 344
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Spud Date: 2010-05-23
+
| 2013
 +
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| style="text-align: right;" | 1,229,213.00
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Unconventional: Yes
+
| 2014
 +
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| style="text-align: right;" | 891,222.00
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Horizontal: Yes
+
| 2015
 +
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| style="text-align: right;" | 678,445.00
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Well Status: ACTIVE
+
| 2016
 +
| [[SWN PROD CO LLC]]
 +
| style="text-align: right;" | 544,296.00
 +
| style="text-align: right;" | 366
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Violations: 0
+
| 2017
 +
| [[SWN PROD CO LLC]]
 +
| style="text-align: right;" | 441,106.00
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Latitude: 41.786655
+
| 2018
 +
| [[SWN PROD CO LLC]]
 +
| style="text-align: right;" | 342,115.00
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Longitude: -76.230807
+
| 2019
 +
| [[SWN PROD CO LLC]]
 +
| style="text-align: right;" | 78,297.00
 +
| style="text-align: right;" | 90
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 
|}
 
|}
== Production Data ==
+
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Waste Type
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Quantity
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Disposal Method
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Waste Facility ID
!scope="col" | OIL QUANTITY
+
|-
!scope="col" | OIL PRODUCTION DAYS
+
| 16APRU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 101.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC018
 
|-
 
|-
| 2010-3
+
| 16DECU
| style="text-align:right;" | 0.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 108.32 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 16FEBU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 100.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC018
 
|-
 
|-
| 2009-0
+
| 16JANU
| style="text-align:right;" | 0.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 109.00 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 16JULU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 92.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC018
 
|-
 
|-
| 2010-2
+
| 16JUNU
| style="text-align:right;" | 0.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 96.00 Bbl
| style="text-align:right;" | 0.0
+
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| style="text-align:right;" | 0.0
+
| WMGR123NC018
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 16MARU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 175.30 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC018
 
|-
 
|-
| 2010-2
+
| 16MAYU
| style="text-align:right;" | 0.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 100.00 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 16NOVU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 16.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC018
 
|-
 
|-
| 2011-1
+
| 16NOVU
| style="text-align:right;" | 0.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 51.50 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 16OCTU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 35.50 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC018
 
|-
 
|-
| 2011-2
+
| 16OCTU
| style="text-align:right;" | 210660.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 42.0
+
| style="text-align: right;" | 36.00 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 16SEPU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 68.50 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC018
 
|-
 
|-
 
| 2012-1
 
| 2012-1
| style="text-align:right;" | 973630.0
+
| Fracturing Fluid Waste (in Tons)
| style="text-align:right;" | 181.0
+
| style="text-align: right;" | 26.79 Tons
| style="text-align:right;" | 0.0
+
| LANDFILL
| style="text-align:right;" | 0.0
+
| 101247
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
 
|-
 
|-
 
| 2012-2
 
| 2012-2
| style="text-align:right;" | 640857.0
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 163.0
+
| style="text-align: right;" | 1,086.87 Tons
| style="text-align:right;" | 0.0
+
| LANDFILL
| style="text-align:right;" | 0.0
+
| 101247
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2013-1
 +
| Fracturing Fluid Waste (in Tons)
 +
| style="text-align: right;" | 51.03 Tons
 +
| LANDFILL
 +
| 101247
 
|-
 
|-
 
| 2013-1
 
| 2013-1
| style="text-align:right;" | 670942.0
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 181.0
+
| style="text-align: right;" | 3,847.00 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2013-2
 +
| Fracing Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 79.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
 
| 2013-2
 
| 2013-2
| style="text-align:right;" | 558271.0
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 184.0
+
| style="text-align: right;" | 1,567.00 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|
| style="text-align:right;" | 0.0
+
|-
| style="text-align:right;" | 0.0
+
| 2014-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 1,534.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2015-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 685.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2015-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 1,066.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2016-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 109.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2016-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 100.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC018
 +
|-
 +
| 2016-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 175.30 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC018
 +
|-
 +
| 2016-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 101.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC018
 +
|-
 +
| 2016-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 100.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
 +
| 2016-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 96.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC018
 
|-
 
|-
| 2014-1
+
| 2016-07
| style="text-align:right;" | 457802.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 181.0
+
| style="text-align: right;" | 92.00 Bbl
| style="text-align:right;" | 0.0
+
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| style="text-align:right;" | 0.0
+
| WMGR123NC018
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2016-09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 68.50 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC018
 
|-
 
|-
| 2014-2
+
| 2016-10
| style="text-align:right;" | 433420.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 184.0
+
| style="text-align: right;" | 35.50 Bbl
| style="text-align:right;" | 0.0
+
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| style="text-align:right;" | 0.0
+
| WMGR123NC018
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2016-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 36.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2015-02
+
| 2016-11
| style="text-align:right;" | 57464.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 28.0
+
| style="text-align: right;" | 16.00 Bbl
| style="text-align:right;" | 0.0
+
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| style="text-align:right;" | 0.0
+
| WMGR123NC018
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2016-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 51.50 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2015-01
+
| 2016-12
| style="text-align:right;" | 65085.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 31.0
+
| style="text-align: right;" | 108.32 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2017-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 341.00 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 
|-
 
|-
| 2015-03
+
| 2017-07
| style="text-align:right;" | 63133.0
+
| Other Oil & Gas Wastes (in Barrels) RWC 899
| style="text-align:right;" | 31.0
+
| style="text-align: right;" | 10.57 Bbl
| style="text-align:right;" | 0.0
+
| SURFACE IMPOUNDMENT
| style="text-align:right;" | 0.0
+
| 826342
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
|}
+
| 2017-07
For data sources see<ref>{{cite web
+
| Produced Fluid (in Barrels) RWC 802
| title = Oil and Gas Historical Production Report
+
| style="text-align: right;" | 49.86 Bbl
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| SURFACE IMPOUNDMENT
| date = 2015-05-26
+
| 826342
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
 
| accessdate = 2015-05-27 }}</ref>
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | PERIOD
 
!scope="col" | TYPE
 
!scope="col" | QUANTITY
 
!scope="col" | UNITS
 
!scope="col" | DISPOSAL METHOD
 
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
| 2012-1
+
| 2017-07
| FLOWBACK FRACTURING SAND
+
| Synthetic Liner Materials (in Tons) RWC 806
| style="text-align:right;" | 26.79
+
| style="text-align: right;" | 0.66 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
| 101247
+
| 100933
| KEYSTONE SANITARY LANDFILL
+
|-
| DUNMORE
+
| 2017-08
| PA
+
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 15.71 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 826342
 +
|-
 +
| 2017-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 41.00 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 826342
 +
|-
 +
| 2017-09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 47.57 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 
|-
 
|-
 +
| 2017-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 49.86 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 
|-
 
|-
| 2012-2
+
| 2017-11
| DRILL CUTTINGS
+
| Other Oil & Gas Wastes (in Barrels) RWC 899
| style="text-align:right;" | 1.0
+
| style="text-align: right;" | 7.14 Bbl
| Tons
+
| SURFACE IMPOUNDMENT
| LANDFILL
+
| 95-16-65420-013
| 101247
 
| KEYSTONE SANITARY LANDFILL
 
| DUNMORE
 
| PA
 
 
|-
 
|-
 +
| 2017-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 32.43 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 
|-
 
|-
| 2013-1
+
| 2017-12
| FLOWBACK FRACTURING SAND
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 51.03
+
| style="text-align: right;" | 31.57 Bbl
| Tons
+
| SURFACE IMPOUNDMENT
| LANDFILL
+
| 95-16-65420-013
| 101247
 
| KEYSTONE SANITARY LANDFILL
 
| DUNMORE
 
| PA
 
 
|-
 
|-
 +
| 2018-01
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 7.14 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 
|-
 
|-
| 2013-1
+
| 2018-01
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 3.0
+
| style="text-align: right;" | 31.43 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2018-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 49.86 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2018-02
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 31.30 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2018-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 18.57 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 34.57 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 826342
 +
|-
 +
| 2018-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.71 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2018-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 46.86 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 826342
 +
|-
 +
| 2018-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 34.43 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 826342
 +
|-
 +
| 2018-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 29.43 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2018-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 34.29 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 18.29 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2018-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 48.00 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 
|-
 
|-
| 2013-2
+
| 2018-08
| FRACING FLUID WASTE
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 79.0
+
| style="text-align: right;" | 15.71 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2018-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 32.00 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2018-09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 33.14 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2018-10
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 22.86 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-10
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 15.71 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2018-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 32.86 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.71 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 
|-
 
|-
| 2013-2
+
| 2018-11
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 1.0
+
| style="text-align: right;" | 33.43 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2018-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 15.71 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2018-12
 +
| Other Oil & Gas Wastes (in Barrels) RWC 899
 +
| style="text-align: right;" | 8.82 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 8.57 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 47.14 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 
|-
 
|-
| 2014-2
+
| 2019-01
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 1.0
+
| style="text-align: right;" | 15.71 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2019-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 13.57 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2019-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 7.71 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2019-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 10.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2019-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 31.43 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Waste Report
+
  | title =Oil and Gas Waste Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-26 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Inspection ID
!scope="col" | DATE
+
!scope="col" | Inspection Category
!scope="col" | DESCRIPTION
+
!scope="col" | Inspection Date
!scope="col" | COMMENT
+
!scope="col" | Inspection Type
!scope="col" | VIOLATION ID
+
!scope="col" | Inspection Result
!scope="col" | VIOLATION CODE
+
!scope="col" | Inspection Comments
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
 
| 2006361
 
| 2006361
| 2011-09-13
+
| Primary Facility
 +
| 09/13/2011
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| Please refer to the Greenzweig Unit #1H inspection report for comments.
 
| Please refer to the Greenzweig Unit #1H inspection report for comments.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2073313
 
| 2073313
| 2012-06-04
+
| Primary Facility
 +
| 06/04/2012
 +
| Administrative/File Review
 
| No Violations Noted
 
| No Violations Noted
 
| Violations and specifcs associated with this inspection have been attached to the Greenzweig Unit #1 inspection report. Permit number is 015-20081.
 
| Violations and specifcs associated with this inspection have been attached to the Greenzweig Unit #1 inspection report. Permit number is 015-20081.
 
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2074918
 
| 2074918
| 2012-06-12
+
| Primary Facility
 +
| 06/12/2012
 +
| Administrative/File Review
 
| No Violations Noted
 
| No Violations Noted
 
| Violations and specfics associated with this inspection report are attached to the Greenzweig Unit #1 inspection report.  Permit number is 015-20081.
 
| Violations and specfics associated with this inspection report are attached to the Greenzweig Unit #1 inspection report.  Permit number is 015-20081.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2075055
 
| 2075055
| 2012-05-15
+
| Primary Facility
 +
| 05/15/2012
 +
| Incident- Response to Accident or Event
 
| No Violations Noted
 
| No Violations Noted
 
| Please refer to the Greenzweig Unit #1 inspection report regarding details of the investigation.  Permit number is 015-20081.
 
| Please refer to the Greenzweig Unit #1 inspection report regarding details of the investigation.  Permit number is 015-20081.
 +
|-
 +
| 2098057
 +
| Primary Facility
 +
| 09/05/2012
 +
| Administrative/File Review
 +
| No Violations Noted
 +
| Violations and specifics associated with this inspection report are attached to the Greenzweig Unit #1 inspection report.  Permit number is 015-20081.
 +
|-
 +
| 2120012
 +
| Primary Facility
 +
| 09/27/2012
 +
| Follow-up Inspection
 +
| No Violations Noted
 +
| Follow-up of onsite fire.  Fitting outside of seperator servicing Greenwich 3 and 4 blew out causing fire which was extinguished immediately.  Crews onsite working to replace unit.
 +
|-
 +
| 2163309
 +
| Primary Facility
 +
| 04/24/2013
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
|  
+
|-
 +
| 2256688
 +
| Primary Facility
 +
| 03/20/2014
 +
| Routine/Partial Inspection
 +
| No Violations Noted
 
|  
 
|  
 
|-
 
|-
 +
| 2603357
 +
| Primary Facility
 +
| 2017-06-06
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| On June 6, 2017, at 1200 hrs., the Department conducted a routine inspection at the SWN Production Company LLC, GU-C-Pad in Herrick Township, Bradford County.  Andrew Hobbins, Water Quality Specialist, represented the Department.  A SWN representative was on site performing maintenance work on the adjacent waste impoundments. 
 +
 +
The site sign, E & S plan and the weekly inspection logs were on site and available for review.  The site was well vegetated and no erosion issues were observed.  PCSM has not been addressed at the site, but the site has been re-permitted and upgraded to an ESCGP-2.  PCSM installation is scheduled for the month of June. 
 +
 +
Seven wells were in production phase during the inspection.  All of the wells were labeled and no bubbling was observed in the well cellars.  Two production tanks and seven GPUs were also observed on site.  The production tanks were observed in secondary containment.  Puddles on the pad surface were low in specific conductivity.  A small area of stained gravel was
 
|-
 
|-
| 2098057
+
| 2818312
| 2012-09-05
+
| Primary Facility
 +
| 2018-12-18
 +
| Site Restoration
 
| No Violations Noted
 
| No Violations Noted
| Violations and specifics associated with this inspection report are attached to the Greenzweig Unit #1 inspection report.  Permit number is 015-20081.  
+
| The DEP conducted a RESTORATION inspection of SWN's Greenzweig (C Pad) in Herrick Twp, Bradford County on 12/18/2018 at 1155 hours. The inspection was conducted in response to a Well Site Restoration Report received by the DEP.  
  
 +
The site has recently been disturbed to install PCSM BMPs per restoration plans. The areas that were disturbed now have straw/hay layered to assist in vegetation growth in the Spring. The areas are poorly vegetated now and are not stabilized. Silt sock was observed beneath the newly constructed Bioretention basin. This site does not meet the requirements for restoration under a well site restoration report. The site is not stabilized with 70% vegetative cover and temporary E&S BMPs are still installed. It is understood that Southwestern has a Consent & Order agreement with the department to install these newly permitted PCSM BMPs. Upon further discussion, the sites already inspected will have to be returned.
  
 +
This Well Site Restoration Report is considered returned at this time.
 +
 +
No
 +
|-
 +
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
|}-->
 +
<!--==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 09/20/2011
 +
| 09/20/2011
 +
| style="text-align: right;" | 6388.00
 +
| style="text-align: right;" | 7,767,060.0
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="30"| 1
 +
| rowspan="4"| PA Local 100 mesh Sand
 +
| rowspan="4"| Superior Well Services
 +
| rowspan="4"| Sand - Bulk - Pennsylvania
 +
| Titanium dioxide
 +
| 13463-67-7
 +
| style="text-align: right;" | 0.10
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 +
|-
 +
| Alumina
 +
| 1344-28-1
 +
| style="text-align: right;" | 1.10
 +
| style="text-align: right;" | 0.15
 +
| style="text-align: right;" |
 +
|-
 +
| Quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 99.90
 +
| style="text-align: right;" | 13.70
 +
| style="text-align: right;" |
 +
|-
 +
| Ferric oxide
 +
| 1309-37-1
 +
| style="text-align: right;" | 0.10
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| KR-153SL
 +
| rowspan="2"| Superior Well Services
 +
| rowspan="2"| Biocide
 +
| 2,2-Dibromo-3-nitrilopropionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 20.00
 +
| style="text-align: right;" | 0.03
 +
| style="text-align: right;" |
 +
|-
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 80.00
 +
| style="text-align: right;" | 0.15
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="0"| WFR-3B
 +
| rowspan="0"| Superior Well Services
 +
| rowspan="0"| Friction Reducer
 +
|- valign="top"
 +
| rowspan="6"| Acid Inhibitor 2 (AI-2)
 +
| rowspan="6"| Superior Well Services
 +
| rowspan="6"| Acid Corrosion Inhibitor
 +
| Glycol Ethers
 
|  
 
|  
 +
| style="text-align: right;" | 20.00
 +
| style="text-align: right;" | 0.00356400
 +
| style="text-align: right;" |
 +
|-
 +
| Poly(oxy-1,2-ethanediyl), alpha-(nonylphenyl)-omega-hydroxy-
 +
, branched
 +
| 68412-54-4
 +
| style="text-align: right;" | 13.00
 +
| style="text-align: right;" | 0.00231700
 +
| style="text-align: right;" |
 +
|-
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.00712800
 +
| style="text-align: right;" |
 +
|-
 +
| Isopropanol
 +
| 67-63-0
 +
| style="text-align: right;" | 15.00
 +
| style="text-align: right;" | 0.00267300
 +
| style="text-align: right;" |
 +
|-
 +
| Propargyl alcohol
 +
| 107-19-7
 +
| style="text-align: right;" | 20.00
 +
| style="text-align: right;" | 0.00356400
 +
| style="text-align: right;" |
 +
|-
 +
| Tar bases, quinoline derivatives, benzyl chloride-quaternized
 +
| 72480-70-7
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00178200
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="3"| Super TSC LT
 +
| rowspan="3"| Superior Well Services
 +
| rowspan="3"| Paraffin & Scale Additive
 +
| Proprietary
 
|  
 
|  
 +
| style="text-align: right;" | 50.00
 +
| style="text-align: right;" | 0.11
 +
| style="text-align: right;" |
 +
|-
 +
| Proprietary
 
|  
 
|  
 +
| style="text-align: right;" | 15.00
 +
| style="text-align: right;" | 0.03
 +
| style="text-align: right;" |
 
|-
 
|-
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.13
 +
| style="text-align: right;" |
 
|-
 
|-
| 2120012
+
|- valign="top"
| 2012-09-27
+
| rowspan="8"| WFR-3B
| No Violations Noted
+
| rowspan="8"| Services Company, USA
| Follow-up of onsite fire.  Fitting outside of seperator servicing Greenwich 3 and 4 blew out causing fire which was extinguished immediately.  Crews onsite working to replace unit.
+
| rowspan="8"| Friction Reducer
 +
| Microparticle
 
|  
 
|  
 +
| style="text-align: right;" | 1.00
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 +
|-
 +
| Ethoxylated C12-16 alcohols
 +
| 68551-12-2
 +
| style="text-align: right;" | 15.00
 +
| style="text-align: right;" | 0.16
 +
| style="text-align: right;" |
 +
|-
 +
| Poly(oxy-1,2-ethanediyl), .alpha.,.alpha.'-[[(9Z)-9-octadecenylimino]di-2,1-ethanediyl]bis[.omega.-hydroxy-
 +
| 26635-93-8
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.05
 +
| style="text-align: right;" |
 +
|-
 +
| 1,2-Propylene glycol
 +
| 57-55-6
 +
| style="text-align: right;" | 15.00
 +
| style="text-align: right;" | 0.16
 +
| style="text-align: right;" |
 +
|-
 
|  
 
|  
 
|  
 
|  
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Distillates, petroleum, hydrotreated light
 +
| 64742-47-8
 +
| style="text-align: right;" | 50.00
 +
| style="text-align: right;" | 0.56
 +
| style="text-align: right;" |
 +
|-
 +
| 1,2-Propylene glycol
 +
| 57-55-6
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.45
 +
| style="text-align: right;" |
 +
|-
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.45
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="4"| PA Specific 30/70 mesh Sand
 +
| rowspan="4"| Superior Well Services
 +
| rowspan="4"| Sand - Bulk - Pennsylvania
 +
| Ferric oxide
 +
| 1309-37-1
 +
| style="text-align: right;" | 0.10
 +
| style="text-align: right;" | 0.07
 +
| style="text-align: right;" |
 +
|-
 +
| Alumina
 +
| 1344-28-1
 +
| style="text-align: right;" | 1.10
 +
| style="text-align: right;" | 0.81
 +
| style="text-align: right;" |
 +
|-
 +
| Titanium dioxide
 +
| 13463-67-7
 +
| style="text-align: right;" | 0.10
 +
| style="text-align: right;" | 0.07
 +
| style="text-align: right;" |
 +
|-
 +
| Quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 99.90
 +
| style="text-align: right;" | 74.03
 +
| style="text-align: right;" |
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="3"| Iron Acid 10M (12.6-18.0)
 +
| rowspan="3"| Superior Well Services
 +
| rowspan="3"| Acid Blend
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 84.10
 +
| style="text-align: right;" | 8.92
 +
| style="text-align: right;" |
 
|-
 
|-
| 2163309
+
| Proprietary
| 2013-04-24
 
| No Violations Noted
 
|
 
|
 
|
 
 
|  
 
|  
 +
| style="text-align: right;" | 1.20
 +
| style="text-align: right;" | 0.12
 +
| style="text-align: right;" |
 +
|-
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 15.80
 +
| style="text-align: right;" | 1.67
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Inspection Report
+
  | title =FracFocus Fracking Chemicals Database
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| date = 2019-04-02
| date = 2015-05-26
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
+
  | accessdate = 2019-06-19 }}</ref>
  | accessdate = 2015-05-27 }}</ref>
+
==References==
== References ==
+
<references/>
{{reflist}}
 
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Revision as of 18:52, 13 July 2019

Well Details

Well ID: 37-015-20422
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Herrick Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 153757
Farm/Lease Name: GREENZWEIG 3H
License Status: Active
Spud Date: 05/23/2010
Permit Date: 9/2/2009
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.786656
Longitude: -76.230808

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 0.00 0.00 0.00
2010 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2011 SOUTHWESTERN ENERGY PROD CO 210,660.00 42 0.00 0 0.00 0
2012 SOUTHWESTERN ENERGY PROD CO 1,614,487.00 344 0.00 0 0.00 0
2013 SOUTHWESTERN ENERGY PROD CO 1,229,213.00 365 0.00 0 0.00 0
2014 SOUTHWESTERN ENERGY PROD CO 891,222.00 365 0.00 0 0.00 0
2015 SOUTHWESTERN ENERGY PROD CO 678,445.00 365 0.00 0 0.00 0
2016 SWN PROD CO LLC 544,296.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 441,106.00 365 0.00 0 0.00 0
2018 SWN PROD CO LLC 342,115.00 365 0.00 0 0.00 0
2019 SWN PROD CO LLC 78,297.00 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
16APRU Produced Fluid (in Barrels) RWC 802 101.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
16DECU Produced Fluid (in Barrels) RWC 802 108.32 Bbl REUSE OTHER THAN ROAD SPREADING
16FEBU Produced Fluid (in Barrels) RWC 802 100.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
16JANU Produced Fluid (in Barrels) RWC 802 109.00 Bbl REUSE OTHER THAN ROAD SPREADING
16JULU Produced Fluid (in Barrels) RWC 802 92.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
16JUNU Produced Fluid (in Barrels) RWC 802 96.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
16MARU Produced Fluid (in Barrels) RWC 802 175.30 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
16MAYU Produced Fluid (in Barrels) RWC 802 100.00 Bbl REUSE OTHER THAN ROAD SPREADING
16NOVU Produced Fluid (in Barrels) RWC 802 16.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
16NOVU Produced Fluid (in Barrels) RWC 802 51.50 Bbl REUSE OTHER THAN ROAD SPREADING
16OCTU Produced Fluid (in Barrels) RWC 802 35.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
16OCTU Produced Fluid (in Barrels) RWC 802 36.00 Bbl REUSE OTHER THAN ROAD SPREADING
16SEPU Produced Fluid (in Barrels) RWC 802 68.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2012-1 Fracturing Fluid Waste (in Tons) 26.79 Tons LANDFILL 101247
2012-2 Drill Cuttings (in Tons) 1,086.87 Tons LANDFILL 101247
2013-1 Fracturing Fluid Waste (in Tons) 51.03 Tons LANDFILL 101247
2013-1 Produced Fluid (in Barrels) 3,847.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-2 Fracing Fluid Waste (in Barrels) 79.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-2 Produced Fluid (in Barrels) 1,567.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Produced Fluid (in Barrels) 1,534.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Produced Fluid (in Barrels) 685.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Produced Fluid (in Barrels) 1,066.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-01 Produced Fluid (in Barrels) RWC 802 109.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-02 Produced Fluid (in Barrels) RWC 802 100.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016-03 Produced Fluid (in Barrels) RWC 802 175.30 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016-04 Produced Fluid (in Barrels) RWC 802 101.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016-05 Produced Fluid (in Barrels) RWC 802 100.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-06 Produced Fluid (in Barrels) RWC 802 96.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016-07 Produced Fluid (in Barrels) RWC 802 92.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016-09 Produced Fluid (in Barrels) RWC 802 68.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016-10 Produced Fluid (in Barrels) RWC 802 35.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016-10 Produced Fluid (in Barrels) RWC 802 36.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-11 Produced Fluid (in Barrels) RWC 802 16.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016-11 Produced Fluid (in Barrels) RWC 802 51.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016-12 Produced Fluid (in Barrels) RWC 802 108.32 Bbl REUSE OTHER THAN ROAD SPREADING
2017-04 Produced Fluid (in Barrels) RWC 802 341.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-07 Other Oil & Gas Wastes (in Barrels) RWC 899 10.57 Bbl SURFACE IMPOUNDMENT 826342
2017-07 Produced Fluid (in Barrels) RWC 802 49.86 Bbl SURFACE IMPOUNDMENT 826342
2017-07 Synthetic Liner Materials (in Tons) RWC 806 0.66 Tons LANDFILL 100933
2017-08 Other Oil & Gas Wastes (in Barrels) RWC 899 15.71 Bbl SURFACE IMPOUNDMENT 826342
2017-08 Produced Fluid (in Barrels) RWC 802 41.00 Bbl SURFACE IMPOUNDMENT 826342
2017-09 Produced Fluid (in Barrels) RWC 802 47.57 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-10 Produced Fluid (in Barrels) RWC 802 49.86 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-11 Other Oil & Gas Wastes (in Barrels) RWC 899 7.14 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-11 Produced Fluid (in Barrels) RWC 802 32.43 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-12 Produced Fluid (in Barrels) RWC 802 31.57 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-01 Other Oil & Gas Wastes (in Barrels) RWC 899 7.14 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-01 Produced Fluid (in Barrels) RWC 802 31.43 Bbl REUSE (AT WELL PAD)
2018-01 Produced Fluid (in Barrels) RWC 802 49.86 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-02 Other Oil & Gas Wastes (in Barrels) RWC 899 31.30 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-02 Produced Fluid (in Barrels) RWC 802 18.57 Bbl REUSE (AT WELL PAD)
2018-02 Produced Fluid (in Barrels) RWC 802 34.57 Bbl SURFACE IMPOUNDMENT 826342
2018-02 Produced Fluid (in Barrels) RWC 802 15.71 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-03 Produced Fluid (in Barrels) RWC 802 46.86 Bbl SURFACE IMPOUNDMENT 826342
2018-04 Produced Fluid (in Barrels) RWC 802 34.43 Bbl SURFACE IMPOUNDMENT 826342
2018-05 Produced Fluid (in Barrels) RWC 802 29.43 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-06 Produced Fluid (in Barrels) RWC 802 34.29 Bbl REUSE (AT WELL PAD)
2018-06 Produced Fluid (in Barrels) RWC 802 18.29 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-07 Produced Fluid (in Barrels) RWC 802 48.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-08 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE (AT WELL PAD)
2018-08 Produced Fluid (in Barrels) RWC 802 32.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-09 Produced Fluid (in Barrels) RWC 802 33.14 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-10 Other Oil & Gas Wastes (in Barrels) RWC 899 22.86 Bbl REUSE (AT WELL PAD)
2018-10 Other Oil & Gas Wastes (in Barrels) RWC 899 15.71 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-10 Produced Fluid (in Barrels) RWC 802 32.86 Bbl REUSE (AT WELL PAD)
2018-10 Produced Fluid (in Barrels) RWC 802 15.71 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-11 Produced Fluid (in Barrels) RWC 802 33.43 Bbl REUSE (AT WELL PAD)
2018-11 Produced Fluid (in Barrels) RWC 802 15.71 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-12 Other Oil & Gas Wastes (in Barrels) RWC 899 8.82 Bbl REUSE (AT WELL PAD)
2018-12 Produced Fluid (in Barrels) RWC 802 8.57 Bbl REUSE (AT WELL PAD)
2018-12 Produced Fluid (in Barrels) RWC 802 47.14 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019-01 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE (AT WELL PAD)
2019-01 Produced Fluid (in Barrels) RWC 802 13.57 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019-02 Produced Fluid (in Barrels) RWC 802 7.71 Bbl REUSE (AT WELL PAD)
2019-03 Produced Fluid (in Barrels) RWC 802 10.00 Bbl REUSE (AT WELL PAD)
2019-03 Produced Fluid (in Barrels) RWC 802 31.43 Bbl SURFACE IMPOUNDMENT 95-16-65420-013

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2006361 Primary Facility 09/13/2011 Routine/Complete Inspection No Violations Noted Please refer to the Greenzweig Unit #1H inspection report for comments.
2073313 Primary Facility 06/04/2012 Administrative/File Review No Violations Noted Violations and specifcs associated with this inspection have been attached to the Greenzweig Unit #1 inspection report. Permit number is 015-20081.
2074918 Primary Facility 06/12/2012 Administrative/File Review No Violations Noted Violations and specfics associated with this inspection report are attached to the Greenzweig Unit #1 inspection report. Permit number is 015-20081.
2075055 Primary Facility 05/15/2012 Incident- Response to Accident or Event No Violations Noted Please refer to the Greenzweig Unit #1 inspection report regarding details of the investigation. Permit number is 015-20081.
2098057 Primary Facility 09/05/2012 Administrative/File Review No Violations Noted Violations and specifics associated with this inspection report are attached to the Greenzweig Unit #1 inspection report. Permit number is 015-20081.
2120012 Primary Facility 09/27/2012 Follow-up Inspection No Violations Noted Follow-up of onsite fire. Fitting outside of seperator servicing Greenwich 3 and 4 blew out causing fire which was extinguished immediately. Crews onsite working to replace unit.
2163309 Primary Facility 04/24/2013 Routine/Complete Inspection No Violations Noted
2256688 Primary Facility 03/20/2014 Routine/Partial Inspection No Violations Noted
2603357 Primary Facility 2017-06-06 Routine/Complete Inspection No Violations Noted On June 6, 2017, at 1200 hrs., the Department conducted a routine inspection at the SWN Production Company LLC, GU-C-Pad in Herrick Township, Bradford County. Andrew Hobbins, Water Quality Specialist, represented the Department. A SWN representative was on site performing maintenance work on the adjacent waste impoundments.

The site sign, E & S plan and the weekly inspection logs were on site and available for review. The site was well vegetated and no erosion issues were observed. PCSM has not been addressed at the site, but the site has been re-permitted and upgraded to an ESCGP-2. PCSM installation is scheduled for the month of June.

Seven wells were in production phase during the inspection. All of the wells were labeled and no bubbling was observed in the well cellars. Two production tanks and seven GPUs were also observed on site. The production tanks were observed in secondary containment. Puddles on the pad surface were low in specific conductivity. A small area of stained gravel was

2818312 Primary Facility 2018-12-18 Site Restoration No Violations Noted The DEP conducted a RESTORATION inspection of SWN's Greenzweig (C Pad) in Herrick Twp, Bradford County on 12/18/2018 at 1155 hours. The inspection was conducted in response to a Well Site Restoration Report received by the DEP.

The site has recently been disturbed to install PCSM BMPs per restoration plans. The areas that were disturbed now have straw/hay layered to assist in vegetation growth in the Spring. The areas are poorly vegetated now and are not stabilized. Silt sock was observed beneath the newly constructed Bioretention basin. This site does not meet the requirements for restoration under a well site restoration report. The site is not stabilized with 70% vegetative cover and temporary E&S BMPs are still installed. It is understood that Southwestern has a Consent & Order agreement with the department to install these newly permitted PCSM BMPs. Upon further discussion, the sites already inspected will have to be returned.

This Well Site Restoration Report is considered returned at this time.

No

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 09/20/2011 09/20/2011 6388.00 7,767,060.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 PA Local 100 mesh Sand Superior Well Services Sand - Bulk - Pennsylvania Titanium dioxide 13463-67-7 0.10 0.01
Alumina 1344-28-1 1.10 0.15
Quartz 14808-60-7 99.90 13.70
Ferric oxide 1309-37-1 0.10 0.01
KR-153SL Superior Well Services Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.03
Water 7732-18-5 80.00 0.15
WFR-3B Superior Well Services Friction Reducer
Acid Inhibitor 2 (AI-2) Superior Well Services Acid Corrosion Inhibitor Glycol Ethers 20.00 0.00356400
Poly(oxy-1,2-ethanediyl), alpha-(nonylphenyl)-omega-hydroxy-

, branched

68412-54-4 13.00 0.00231700
Water 7732-18-5 40.00 0.00712800
Isopropanol 67-63-0 15.00 0.00267300
Propargyl alcohol 107-19-7 20.00 0.00356400
Tar bases, quinoline derivatives, benzyl chloride-quaternized 72480-70-7 10.00 0.00178200
Super TSC LT Superior Well Services Paraffin & Scale Additive Proprietary 50.00 0.11
Proprietary 15.00 0.03
Water 7732-18-5 60.00 0.13
WFR-3B Services Company, USA Friction Reducer Microparticle 1.00 0.01
Ethoxylated C12-16 alcohols 68551-12-2 15.00 0.16
Poly(oxy-1,2-ethanediyl), .alpha.,.alpha.'-[[(9Z)-9-octadecenylimino]di-2,1-ethanediyl]bis[.omega.-hydroxy- 26635-93-8 5.00 0.05
1,2-Propylene glycol 57-55-6 15.00 0.16
Distillates, petroleum, hydrotreated light 64742-47-8 50.00 0.56
1,2-Propylene glycol 57-55-6 40.00 0.45
Water 7732-18-5 40.00 0.45
PA Specific 30/70 mesh Sand Superior Well Services Sand - Bulk - Pennsylvania Ferric oxide 1309-37-1 0.10 0.07
Alumina 1344-28-1 1.10 0.81
Titanium dioxide 13463-67-7 0.10 0.07
Quartz 14808-60-7 99.90 74.03
Iron Acid 10M (12.6-18.0) Superior Well Services Acid Blend Water 7732-18-5 84.10 8.92
Proprietary 1.20 0.12
Hydrochloric acid 7647-01-0 15.80 1.67

For data sources see[7]