X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-015-21669"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-015-21669
 
| Well ID: 37-015-21669
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.715327, -76.34108 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="14" | {{#display_map: 41.715328, -76.341081 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Bradford County, Pennsylvania|Bradford]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Asylum Township, Bradford County, Pennsylvania|Asylum Township]]
+
| State: Pennsylvania
 +
|-
 +
| County: [[Bradford_County,_Pennsylvania|Bradford]]
 +
|-
 +
| Municipality: [[Asylum Township,_Bradford_County,_Pennsylvania|Asylum Township]]
 
|-
 
|-
 
| Operator Name: [[CHIEF OIL & GAS LLC]]
 
| Operator Name: [[CHIEF OIL & GAS LLC]]
 
|-
 
|-
| Well Pad ID: [[149071|149071]]
+
| Well Pad ID: [[149071]]
 
|-
 
|-
 
| Farm/Lease Name: PMG GOD UNIT A 4H
 
| Farm/Lease Name: PMG GOD UNIT A 4H
 
|-
 
|-
| First Permit Date: 2011-05-18
+
| License Status: Active
 
|-
 
|-
| Last Permit Date: 2011-05-18
+
| Spud Date: 06/17/2011
 
|-
 
|-
| Spud Date: 2011-06-17
+
| Permit Date: 5/18/2011
 
|-
 
|-
| Unconventional: Yes
+
| Unconventional Well: Y
 
|-
 
|-
| Horizontal: Yes
+
| Configuration: Horizontal Well
 
|-
 
|-
| Well Status: ACTIVE
+
| Latitude: 41.715328
|-
 
| Violations: 0
 
|-
 
| Latitude: 41.715327
 
|-
 
| Longitude: -76.34108
 
 
|-
 
|-
 +
| Longitude: -76.341081
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Operator Name
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Gas Production Days
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | OIL QUANTITY
+
!scope="col" | Oil Production Days
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 
|-
 
|-
| 2011-1
+
| 2011
| style="text-align:right;" | 0.0
+
| [[CHIEF OIL & GAS LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2012
 +
| [[CHIEF OIL & GAS LLC]]
 +
| style="text-align: right;" | 1,844,219.90
 +
| style="text-align: right;" | 305
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-2
+
| 2013
| style="text-align:right;" | 0.0
+
| [[CHIEF OIL & GAS LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 2,192,486.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 361
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2014
 +
| [[CHIEF OIL & GAS LLC]]
 +
| style="text-align: right;" | 886,111.00
 +
| style="text-align: right;" | 295
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2012-1
+
| 2015
| style="text-align:right;" | 721870.9
+
| [[CHIEF OIL & GAS LLC]]
| style="text-align:right;" | 121.0
+
| style="text-align: right;" | 800,250.23
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 310
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2016
 +
| [[CHIEF OIL & GAS LLC]]
 +
| style="text-align: right;" | 1,049,433.44
 +
| style="text-align: right;" | 362
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2012-2
+
| 2017
| style="text-align:right;" | 1122349.0
+
| [[CHIEF OIL & GAS LLC]]
| style="text-align:right;" | 184.0
+
| style="text-align: right;" | 755,409.47
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
|-
+
| style="text-align: right;" | 0
|-
 
| 2013-1
 
| style="text-align:right;" | 1194070.0
 
| style="text-align:right;" | 181.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2013-2
 
| style="text-align:right;" | 998416.0
 
| style="text-align:right;" | 180.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2018
 +
| [[CHIEF OIL & GAS LLC]]
 +
| style="text-align: right;" | 652,411.00
 +
| style="text-align: right;" | 358
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2014-1
+
| 2019
| style="text-align:right;" | 677892.0
+
| [[CHIEF OIL & GAS LLC]]
| style="text-align:right;" | 181.0
+
| style="text-align: right;" | 205,236.96
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 90
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
|-
+
| style="text-align: right;" | 0
|-
 
| 2014-2
 
| style="text-align:right;" | 208219.0
 
| style="text-align:right;" | 114.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-02
 
| style="text-align:right;" | 0.02
 
| style="text-align:right;" | 1.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-01
 
| style="text-align:right;" | 15459.0
 
| style="text-align:right;" | 9.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-03
 
| style="text-align:right;" | 69857.42
 
| style="text-align:right;" | 31.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Production Report
+
  | title =Oil and Gas Production Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-27 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Waste Data ==
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Waste Type
!scope="col" | QUANTITY
+
!scope="col" | Quantity
!scope="col" | UNITS
+
!scope="col" | Disposal Method
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Waste Facility ID
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
 
| 2011-1
 
| 2011-1
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 37.58
+
| style="text-align: right;" | 331.55 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
| NY31346244
+
| 301626
| HAKES LANDFILL
 
| PAINTED POST
 
| NY
 
|-
 
 
|-
 
|-
 
| 2011-1
 
| 2011-1
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 331.55
+
| style="text-align: right;" | 37.58 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
| 301626
+
| NY31346244
| WHITE PINES LANDFILL
 
| MILLVILLE
 
| PA
 
|-
 
 
|-
 
|-
 
| 2011-1
 
| 2011-1
| FRACING FLUID WASTE
+
| Fracing Fluid Waste (in Barrels)
| style="text-align:right;" | 65.0
+
| style="text-align: right;" | 65.00 Bbl
| Bbl
 
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| PA0008451
 
| PA0008451
| SUNBURY GENERATION WASTE WATER TRMT FAC
 
| SHAMOKIN DAM
 
| PA
 
|-
 
 
|-
 
|-
 
| 2011-2
 
| 2011-2
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 615.31
+
| style="text-align: right;" | 615.31 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| 301626
 
| 301626
| WHITE PINES LANDFILL
 
| MILLVILLE
 
| PA
 
|-
 
 
|-
 
|-
 
| 2012-1
 
| 2012-1
| FRACING FLUID WASTE
+
| Fracing Fluid Waste (in Barrels)
| style="text-align:right;" | 2.0
+
| style="text-align: right;" | 2,229.00 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2012-1
 
| 2012-1
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 2.0
+
| style="text-align: right;" | 2,011.00 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2012-2
 
| 2012-2
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 1.0
+
| style="text-align: right;" | 1,062.20 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2013-1
 
| 2013-1
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 1.0
+
| style="text-align: right;" | 1,075.20 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
|
 
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
 
|  
 
|  
 
|-
 
|-
 +
| 2013-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 113.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW018
 
|-
 
|-
 
| 2013-2
 
| 2013-2
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 360.0
+
| style="text-align: right;" | 360.00 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2014-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 245.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2014-2
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 276.60 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
 +
| 2015-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 88.31 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2013-2
+
| 2015-2
| PRODUCED FLUID
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 113.0
+
| style="text-align: right;" | 145.73 Bbl
| Bbl
+
| REUSE OTHER THAN ROAD SPREADING
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
+
|  
| WMGR123D001X
 
| TERRAQUA RESOURCE MANAGEMENT
 
| WILLIAMSPORT
 
| PA
 
 
|-
 
|-
 +
| 2016-1
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 207.51 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2014-1
+
| 2016-2
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 245.0
+
| style="text-align: right;" | 164.13 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2017-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 30.20 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 33.17 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2017-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 36.41 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2014-2
+
| 2017-08
| PRODUCED FLUID
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 276.6
+
| style="text-align: right;" | 27.66 Bbl
| Bbl
+
| REUSE (AT WELL PAD)
| REUSE OTHER THAN ROAD SPREADING
 
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2017-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 235.33 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2018-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 20.57 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Waste Report
+
  | title =Oil and Gas Waste Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-26 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Inspection ID
!scope="col" | DATE
+
!scope="col" | Inspection Category
!scope="col" | DESCRIPTION
+
!scope="col" | Inspection Date
!scope="col" | COMMENT
+
!scope="col" | Inspection Type
!scope="col" | VIOLATION ID
+
!scope="col" | Inspection Result
!scope="col" | VIOLATION CODE
+
!scope="col" | Inspection Comments
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
 
| 1985377
 
| 1985377
| 2011-07-01
+
| Primary Facility
 +
| 07/01/2011
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
| PATTERSON 251 - DRILLING WITH MUD
 
| PATTERSON 251 - DRILLING WITH MUD
KICKOFF SWITCHING TO INVERT
+
|-
 +
| 1990557
 +
| Primary Facility
 +
| 07/25/2011
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Conductor and surface casing cut off.  Gauges on 13 3/8 and 9 5/8 -0psi.  Vented to tank.
 +
|-
 +
| 2298712
 +
| Primary Facility
 +
| 08/11/2014
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 +
|-
 +
| 2306438
 +
| Primary Facility
 +
| 09/19/2014
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| While in the process of surveying the site, I observed an area of standing water on the pad surface behind the reuse water tank battery.  There was also an area of standing water inside the tank battery.  The water inside the tank battery appeared to be sediment laden.  It had a rust like appearance to it; orange and brown in color.  Based on visual observance of the discolored water in containment and water on the pad surface which appeared to be emanating from under the containment system, I used  an Extech, ExStik (2) pH, Conductivity, Salinty and TDS meter to field screen the water for conductivity.  Conductivity readings were in the range of (6-8) milliSiemens/cm in containment.  I recorded over the limit conductivity readings on the pad surface just outside containment and in standing water pooled in rocks in the site perimeter ditch.  The highest possible recorded reading on this meter is (19.99) milliSiemens/cm.
 +
|-
 +
| 2308792
 +
| Primary Facility
 +
| 09/26/2014
 +
| Follow-up Inspection
 +
| No Violations Noted
 +
| I met with (2) employees of Mr. Dirt, the company Chief Oil and Gas has subcontracted to remediate an area of staining and potential contamination of the NW corner of the pad surface.  Thus far Mr. Dirt has filled (7) steel containers of excavated material in the general area where I recorded elevated conductivity readings in surface water next to the reuse water and gas buster tank battery.  Please see the 9/19/14 inspection report, which describes the details of the conditions observed at the site and the conductivity readings recorded on my meter.  The remediation of the pad surface was temporarily halted as Mr. Dirt was waiting for another container as they have planned to continue to excavate the impacted area.  The 8th container as part of the remediation process is expected to be the final container as part of the process, according to Mr. Dirt.  Mr. Dirt stated that around (250) cubic yards of the pad surface has been excavated and filled into containers up to this point.
 +
|-
 +
| 2440942
 +
| Primary Facility
 +
| 2016-01-14
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 +
|-
 +
| 2508232
 +
| Primary Facility
 +
| 2016-08-04
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 +
|-
 +
| 2518849
 +
| Primary Facility
 +
| 2016-09-13
 +
| Site Restoration
 +
| No Violations Noted
 +
|
 +
|-
 +
| 2642803
 +
| Primary Facility
 +
| 2017-10-02
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Four wells staged for production. Site has interim restoration.  Four separators within containment. One production tank severely corroded.  The operator will empty the 1H tank  by the afternoon of 10/2/2017. No violations noted at this time.
 +
|-
 +
| 2803114
 +
| Primary Facility
 +
| 2018-11-13
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| This site was restored and the NOT was acknowledged 8/8/16.
  
 +
Four wells are staged for production. Four GPUs are present within secondary containment. This containment was in good condition overall. One steel produced water tank is present and in good condition. The secondary containment around the produced water tank is steel with plastic lining and is in good condition.
  
20 set at 87'
+
A labeled methanol container is present near the well heads. This container sits on top of a black plastic tank. The department recommends more substantial secondary containment for this container. An unlabeled green container is also present near the well heads. The department recommends labeling this container.
13 3/8 set at 543 - 96 bbls, 15.7#, 28 bbls ret (UNIVERSAL)
 
9 5/8 set at 1831 - 97 bbls. 41 bbls ret. (HALIRBURTON)
 
  
vd ~ 6300'
+
Several portions of the pad which had been restored and vegetated have been disturbed by truck traffic. In these areas, the soil has been compacted, some vegetated has died, and water is ponding. The department recommends restabilizing these areas as needed in the spring.
~MD -133348'
 
  
kICKOFF 5750'
+
Post Construction Stormwater Management (PCSM) is handle
 +
|-
 +
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
|}-->
 +
<!--==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 11/29/2011
 +
| 11/29/2011
 +
| style="text-align: right;" | 6190.00
 +
| style="text-align: right;" | 6,741,630.0
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="20"| 1
 +
| rowspan="5"| Super Scale Control TSC
 +
| rowspan="5"| Superior Well Services
 +
| rowspan="5"| Scale Inhibitor
 +
| 1,2,4-Butanetricarboxylic acid, 2-phosphono-
 +
| 37971-36-1
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 
|  
 
|  
 
|  
 
|  
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Anionic Polymer
 
|  
 
|  
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 
|-
 
|-
 +
| 1,2-Propylene glycol
 +
| 57-55-6
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 0.03
 +
| style="text-align: right;" |
 
|-
 
|-
| 1990557
+
| Anionic Copolymer
| 2011-07-25
 
| No Violations Noted
 
| Conductor and surface casing cut off.  Gauges on 13 3/8 and 9 5/8 -0psi.  Vented to tank.
 
 
|  
 
|  
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="5"| WFR-3B
 +
| rowspan="5"| Superior Well Services
 +
| rowspan="5"| Friction Reducer
 +
| Stoddard solvent
 +
| 8052-41-3
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| 1,2-Propylene glycol
 +
| 57-55-6
 +
| style="text-align: right;" | 25.00
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Ethoxylated C12-16 alcohols
 +
| 68551-12-2
 +
| style="text-align: right;" | 4.00
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 
|  
 
|  
 
|  
 
|  
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Distillates, petroleum, hydrotreated light
 +
| 64742-47-8
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 0.11
 +
| style="text-align: right;" |
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="2"| FE OXCLEAR
 +
| rowspan="2"| Superior Well Services
 +
| rowspan="2"| Oxygen Scavenger
 +
| Ammonium bisulfite
 +
| 10192-30-0
 +
| style="text-align: right;" |
 +
| style="text-align: right;" | 0.00300000
 +
| style="text-align: right;" |
 
|-
 
|-
| 2306438
 
| 2014-09-19
 
| No Violations Noted
 
| While in the process of surveying the site
 
 
|  
 
|  
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="5"| KR-153SL
 +
| rowspan="5"| Superior Well Services
 +
| rowspan="5"| Biocide
 +
| Ethylene glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Polyethylene glycol
 +
| 25322-68-3
 +
| style="text-align: right;" | 5000.00
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 
|  
 
|  
 
|  
 
|  
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Diethylene glycol
 +
| 111-46-6
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| 2,2-Dibromo-3-nitrilopropionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 20.00
 +
| style="text-align: right;" | 0.02
 +
| style="text-align: right;" |
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="2"| Sand (Proppant)
 +
| rowspan="2"| Superior Well Services
 +
| rowspan="2"| Propping Agent
 +
| Quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 99.90
 +
| style="text-align: right;" | 22.96
 +
| style="text-align: right;" |
 
|-
 
|-
| 2308792
 
| 2014-09-26
 
| No Violations Noted
 
| I met with (2) employees of Mr. Dirt
 
 
|  
 
|  
 
|  
 
|  
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Water
 +
| rowspan="1"|
 +
| rowspan="1"| Base Fluid
 +
| Fresh Water
 
|  
 
|  
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 76.86
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Inspection Report
+
  | title =FracFocus Fracking Chemicals Database
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| date = 2019-04-02
| date = 2015-05-26
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
+
  | accessdate = 2019-06-19 }}</ref>
  | accessdate = 2015-05-27 }}</ref>
+
==References==
== References ==
+
<references/>
{{reflist}}
 
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Revision as of 20:54, 13 July 2019

Well Details

Well ID: 37-015-21669
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Asylum Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 149071
Farm/Lease Name: PMG GOD UNIT A 4H
License Status: Active
Spud Date: 06/17/2011
Permit Date: 5/18/2011
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.715328
Longitude: -76.341081

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2012 CHIEF OIL & GAS LLC 1,844,219.90 305 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 2,192,486.00 361 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 886,111.00 295 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 800,250.23 310 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 1,049,433.44 362 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 755,409.47 365 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 652,411.00 358 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 205,236.96 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2011-1 Drill Cuttings (in Tons) 331.55 Tons LANDFILL 301626
2011-1 Drill Cuttings (in Tons) 37.58 Tons LANDFILL NY31346244
2011-1 Fracing Fluid Waste (in Barrels) 65.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2011-2 Drill Cuttings (in Tons) 615.31 Tons LANDFILL 301626
2012-1 Fracing Fluid Waste (in Barrels) 2,229.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012-1 Produced Fluid (in Barrels) 2,011.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012-2 Produced Fluid (in Barrels) 1,062.20 Bbl REUSE OTHER THAN ROAD SPREADING
2013-1 Produced Fluid (in Barrels) 1,075.20 Bbl REUSE OTHER THAN ROAD SPREADING
2013-2 Produced Fluid (in Barrels) 113.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2013-2 Produced Fluid (in Barrels) 360.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Produced Fluid (in Barrels) 245.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Produced Fluid (in Barrels) 276.60 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Produced Fluid (in Barrels) 88.31 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Produced Fluid (in Barrels) 145.73 Bbl REUSE OTHER THAN ROAD SPREADING
2016-1 Produced Fluid (in Barrels) RWC 802 207.51 Bbl REUSE OTHER THAN ROAD SPREADING
2016-2 Produced Fluid (in Barrels) RWC 802 164.13 Bbl REUSE OTHER THAN ROAD SPREADING
2017-02 Produced Fluid (in Barrels) RWC 802 30.20 Bbl REUSE (AT WELL PAD)
2017-03 Produced Fluid (in Barrels) RWC 802 33.17 Bbl REUSE (AT WELL PAD)
2017-05 Produced Fluid (in Barrels) RWC 802 36.41 Bbl REUSE (AT WELL PAD)
2017-08 Produced Fluid (in Barrels) RWC 802 27.66 Bbl REUSE (AT WELL PAD)
2017-10 Produced Fluid (in Barrels) RWC 802 235.33 Bbl REUSE (AT WELL PAD)
2018-07 Produced Fluid (in Barrels) RWC 802 20.57 Bbl REUSE (AT WELL PAD)

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1985377 Primary Facility 07/01/2011 Drilling/Alteration No Violations Noted PATTERSON 251 - DRILLING WITH MUD
1990557 Primary Facility 07/25/2011 Routine/Complete Inspection No Violations Noted Conductor and surface casing cut off. Gauges on 13 3/8 and 9 5/8 -0psi. Vented to tank.
2298712 Primary Facility 08/11/2014 Routine/Complete Inspection No Violations Noted
2306438 Primary Facility 09/19/2014 Routine/Complete Inspection No Violations Noted While in the process of surveying the site, I observed an area of standing water on the pad surface behind the reuse water tank battery. There was also an area of standing water inside the tank battery. The water inside the tank battery appeared to be sediment laden. It had a rust like appearance to it; orange and brown in color. Based on visual observance of the discolored water in containment and water on the pad surface which appeared to be emanating from under the containment system, I used an Extech, ExStik (2) pH, Conductivity, Salinty and TDS meter to field screen the water for conductivity. Conductivity readings were in the range of (6-8) milliSiemens/cm in containment. I recorded over the limit conductivity readings on the pad surface just outside containment and in standing water pooled in rocks in the site perimeter ditch. The highest possible recorded reading on this meter is (19.99) milliSiemens/cm.
2308792 Primary Facility 09/26/2014 Follow-up Inspection No Violations Noted I met with (2) employees of Mr. Dirt, the company Chief Oil and Gas has subcontracted to remediate an area of staining and potential contamination of the NW corner of the pad surface. Thus far Mr. Dirt has filled (7) steel containers of excavated material in the general area where I recorded elevated conductivity readings in surface water next to the reuse water and gas buster tank battery. Please see the 9/19/14 inspection report, which describes the details of the conditions observed at the site and the conductivity readings recorded on my meter. The remediation of the pad surface was temporarily halted as Mr. Dirt was waiting for another container as they have planned to continue to excavate the impacted area. The 8th container as part of the remediation process is expected to be the final container as part of the process, according to Mr. Dirt. Mr. Dirt stated that around (250) cubic yards of the pad surface has been excavated and filled into containers up to this point.
2440942 Primary Facility 2016-01-14 Routine/Complete Inspection No Violations Noted
2508232 Primary Facility 2016-08-04 Routine/Complete Inspection No Violations Noted
2518849 Primary Facility 2016-09-13 Site Restoration No Violations Noted
2642803 Primary Facility 2017-10-02 Routine/Complete Inspection No Violations Noted Four wells staged for production. Site has interim restoration. Four separators within containment. One production tank severely corroded. The operator will empty the 1H tank by the afternoon of 10/2/2017. No violations noted at this time.
2803114 Primary Facility 2018-11-13 Routine/Complete Inspection No Violations Noted This site was restored and the NOT was acknowledged 8/8/16.

Four wells are staged for production. Four GPUs are present within secondary containment. This containment was in good condition overall. One steel produced water tank is present and in good condition. The secondary containment around the produced water tank is steel with plastic lining and is in good condition.

A labeled methanol container is present near the well heads. This container sits on top of a black plastic tank. The department recommends more substantial secondary containment for this container. An unlabeled green container is also present near the well heads. The department recommends labeling this container.

Several portions of the pad which had been restored and vegetated have been disturbed by truck traffic. In these areas, the soil has been compacted, some vegetated has died, and water is ponding. The department recommends restabilizing these areas as needed in the spring.

Post Construction Stormwater Management (PCSM) is handle

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 11/29/2011 11/29/2011 6190.00 6,741,630.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Super Scale Control TSC Superior Well Services Scale Inhibitor 1,2,4-Butanetricarboxylic acid, 2-phosphono- 37971-36-1
Anionic Polymer
1,2-Propylene glycol 57-55-6 0.03
Anionic Copolymer
WFR-3B Superior Well Services Friction Reducer Stoddard solvent 8052-41-3 10.00
1,2-Propylene glycol 57-55-6 25.00
Ethoxylated C12-16 alcohols 68551-12-2 4.00
Distillates, petroleum, hydrotreated light 64742-47-8 0.11
FE OXCLEAR Superior Well Services Oxygen Scavenger Ammonium bisulfite 10192-30-0 0.00300000
KR-153SL Superior Well Services Biocide Ethylene glycol 107-21-1 100.00
Polyethylene glycol 25322-68-3 5000.00
Diethylene glycol 111-46-6
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.02
Sand (Proppant) Superior Well Services Propping Agent Quartz 14808-60-7 99.90 22.96
Water Base Fluid Fresh Water 100.00 76.86

For data sources see[7]

References