| Well ID: 37-015-22832 | | Well ID: 37-015-22832 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="14" | {{#display_map: 41.569228, -76.219367 | width=100% | height=100% }} |
|- | |- | ||
− | | | + | | Country: United States |
|- | |- | ||
− | | Municipality: [[Wilmot Township, | + | | State: Pennsylvania |
+ | |- | ||
+ | | County: [[Bradford_County,_Pennsylvania|Bradford]] | ||
+ | |- | ||
+ | | Municipality: [[Wilmot Township,_Bradford_County,_Pennsylvania|Wilmot Township]] | ||
|- | |- | ||
| Operator Name: [[CHESAPEAKE APPALACHIA LLC]] | | Operator Name: [[CHESAPEAKE APPALACHIA LLC]] | ||
|- | |- | ||
− | | Well Pad ID: [[ | + | | Well Pad ID: [[150854]] |
|- | |- | ||
| Farm/Lease Name: BIM BRA 2H | | Farm/Lease Name: BIM BRA 2H | ||
|- | |- | ||
− | | | + | | License Status: Active |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | Spud Date: 07/07/2014 |
|- | |- | ||
− | | | + | | Permit Date: 2/20/2014 |
|- | |- | ||
− | | Well | + | | Unconventional Well: Y |
|- | |- | ||
− | | | + | | Configuration: Horizontal Well |
|- | |- | ||
− | | Latitude: 41. | + | | Latitude: 41.569228 |
− | |||
− | |||
|- | |- | ||
+ | | Longitude: -76.219367 | ||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Permits Issued Detail Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref><ref>{{cite web | ||
+ | | title = Spud Data Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-04-30 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-16 }}</ref><ref>{{cite web | ||
+ | | title = Oil and Gas Well Pad Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Operator Name |
− | !scope="col" | | + | !scope="col" | Gas Quantity (mcf) |
− | !scope="col" | | + | !scope="col" | Gas Production Days |
− | !scope="col" | | + | !scope="col" | Oil Quantity (bbl) |
− | !scope="col" | | + | !scope="col" | Oil Production Days |
− | !scope="col" | | + | !scope="col" | Water Quantity (bbl) |
+ | !scope="col" | Water Production Days | ||
|- | |- | ||
− | | 2014 | + | | 2014 |
− | | style="text-align:right;" | 0. | + | | [[CHESAPEAKE APPALACHIA LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2015 | ||
+ | | [[CHESAPEAKE APPALACHIA LLC]] | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2016 |
− | | style="text-align:right;" | | + | | [[CHESAPEAKE APPALACHIA LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 1,945,667.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 132 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2017 | ||
+ | | [[CHESAPEAKE APPALACHIA LLC]] | ||
+ | | style="text-align: right;" | 3,297,726.00 | ||
+ | | style="text-align: right;" | 290 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2018 |
− | | style="text-align:right;" | | + | | [[CHESAPEAKE APPALACHIA LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 1,853,854.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 362 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2019 |
− | | | + | | [[CHESAPEAKE APPALACHIA LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 371,403.00 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 90 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0 |
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Production Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
== Waste Data == | == Waste Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Waste Type |
− | !scope="col" | | + | !scope="col" | Quantity |
− | !scope="col" | | + | !scope="col" | Disposal Method |
− | !scope="col" | | + | !scope="col" | Waste Facility ID |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2014-2 | | 2014-2 | ||
− | | | + | | Drill Cuttings (in Tons) |
− | | style="text-align:right;" | 431.29 | + | | style="text-align: right;" | 431.29 Tons |
− | |||
| LANDFILL | | LANDFILL | ||
| 8-0728-0004/013 | | 8-0728-0004/013 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2014-2 | ||
+ | | Drill Cuttings (in Tons) | ||
+ | | style="text-align: right;" | 432.99 Tons | ||
+ | | LANDFILL | ||
+ | | 8-4630-00010/00 | ||
|- | |- | ||
| 2014-2 | | 2014-2 | ||
− | | | + | | Drill Cuttings (in Tons) |
− | | style="text-align:right;" | 216. | + | | style="text-align: right;" | 216.50 Tons |
− | |||
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
| WMGR097R017 | | WMGR097R017 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2015-1 | ||
+ | | Drill Cuttings (in Tons) | ||
+ | | style="text-align: right;" | 5.13 Tons | ||
+ | | LANDFILL | ||
+ | | THR029 | ||
+ | |- | ||
+ | | 2016-1 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 17.50 Bbl | ||
+ | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
+ | | WMGR123 | ||
+ | |- | ||
+ | | 2016-1 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 51.59 Bbl | ||
+ | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
+ | | WMGR123NC008 | ||
+ | |- | ||
+ | | 2016-2 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 220.00 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123NC008 | ||
|- | |- | ||
− | | | + | | 2016-2 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 216.00 Bbl |
− | | Tons | + | | RESIDUAL WASTE PROCESSING FACILITY |
+ | | WMGR123NW011 | ||
+ | |- | ||
+ | | 2016-2 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 514.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2016-2 | ||
+ | | Synthetic Liner Materials (in Tons) RWC 806 | ||
+ | | style="text-align: right;" | 1.79 Tons | ||
| LANDFILL | | LANDFILL | ||
− | | 8- | + | | 8-0728-0004/013 |
− | | | + | |- |
− | | | + | | 2017-02 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
+ | | style="text-align: right;" | 103.00 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123NW011 | ||
+ | |- | ||
+ | | 2017-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 354.00 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123NW011 | ||
|- | |- | ||
− | | | + | | 2017-04 |
− | + | | Produced Fluid (in Barrels) RWC 802 | |
− | + | | style="text-align: right;" | 218.00 Bbl | |
− | + | | RESIDUAL WASTE PROCESSING FACILITY | |
− | + | | WMGR123NC010 | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2017-05 |
− | | | + | | Other Oil & Gas Wastes (in Barrels) RWC 899 |
− | | | + | | style="text-align: right;" | 18.40 Bbl |
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2017-05 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 123.00 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123NW011 | ||
+ | |- | ||
+ | | 2017-06 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 16.70 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123NC008 | ||
+ | |- | ||
+ | | 2017-06 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 55.20 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2017-06 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 307.00 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123NC008 | ||
+ | |- | ||
+ | | 2017-07 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 650.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2017-08 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 302.60 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123NC008 | ||
+ | |- | ||
+ | | 2017-08 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 872.00 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
+ | | 2017-09 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 131.20 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123NC008 | ||
|- | |- | ||
− | | | + | | 2017-09 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | | + | | style="text-align: right;" | 309.10 Bbl |
− | | | + | | REUSE (AT WELL PAD) |
| | | | ||
+ | |- | ||
+ | | 2017-09 | ||
+ | | Synthetic Liner Materials (in Tons) RWC 806 | ||
+ | | style="text-align: right;" | 0.60 Tons | ||
+ | | CENT WASTE TRT FAC NPDES DISCHARGE | ||
+ | | PAG034815 | ||
+ | |- | ||
+ | | 2017-09 | ||
+ | | Waste Water Treatment Sludge (in Tons) RWC 804 | ||
+ | | style="text-align: right;" | 6.20 Tons | ||
+ | | LANDFILL | ||
+ | | 301626 | ||
+ | |- | ||
+ | | 2017-11 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 219.30 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2017-12 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 27.50 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123NC018 | ||
+ | |- | ||
+ | | 2017-12 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 135.90 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
+ | | 2018-01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 26.80 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123NC018 | ||
|- | |- | ||
− | | | + | | 2018-01 |
− | + | | Produced Fluid (in Barrels) RWC 802 | |
− | | | + | | style="text-align: right;" | 27.80 Bbl |
− | | | + | | REUSE (AT WELL PAD) |
| | | | ||
+ | |- | ||
+ | | 2018-01 | ||
+ | | Waste Water Treatment Sludge (in Tons) RWC 804 | ||
+ | | style="text-align: right;" | 0.70 Tons | ||
+ | | LANDFILL | ||
+ | | 301626 | ||
+ | |- | ||
+ | | 2018-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 20.00 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123NC008 | ||
+ | |- | ||
+ | | 2018-03 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 54.30 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2018-03 | ||
+ | | Waste Water Treatment Sludge (in Tons) RWC 804 | ||
+ | | style="text-align: right;" | 0.60 Tons | ||
+ | | LANDFILL | ||
+ | | 301626 | ||
+ | |- | ||
+ | | 2018-05 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 54.30 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
+ | | 2018-06 | ||
+ | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
+ | | style="text-align: right;" | 18.40 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123NC008 | ||
|- | |- | ||
− | | | + | | 2018-06 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | | + | | style="text-align: right;" | 27.50 Bbl |
− | | | + | | REUSE (AT WELL PAD) |
− | |||
| | | | ||
+ | |- | ||
+ | | 2018-06 | ||
+ | | Synthetic Liner Materials (in Tons) RWC 806 | ||
+ | | style="text-align: right;" | 0.90 Tons | ||
+ | | CENT WASTE TRT FAC NPDES DISCHARGE | ||
+ | | PAG034815 | ||
+ | |- | ||
+ | | 2018-07 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 27.00 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123NC018 | ||
+ | |- | ||
+ | | 2018-07 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 54.30 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2018-09 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 54.10 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123NC018 | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Waste Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
− | + | == Inspection Data == | |
− | == | + | ==== Inspections Performed ==== |
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Inspection ID |
− | !scope="col" | | + | !scope="col" | Inspection Category |
− | !scope="col" | | + | !scope="col" | Inspection Date |
− | !scope="col" | | + | !scope="col" | Inspection Type |
− | !scope="col" | | + | !scope="col" | Inspection Result |
− | !scope="col" | | + | !scope="col" | Inspection Comments |
− | |||
|- | |- | ||
− | | | + | | 2283444 |
− | | | + | | Primary Facility |
− | | | + | | 06/27/2014 |
− | | | + | | Preoperation Inspection |
− | | | + | | No Violations Noted |
− | | | + | | |
− | |||
|- | |- | ||
+ | | 2308484 | ||
+ | | Primary Facility | ||
+ | | 09/30/2014 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2324842 |
− | | | + | | Primary Facility |
− | | | + | | 11/24/2014 |
− | | | + | | Routine/Complete Inspection |
− | | | + | | No Violations Noted |
− | | | + | | While in the process of surveying the containment and equipment and evaluation site conditions, I observed the evidence of a petroleum product release on the ground surface of the Pad at 41° 34’ 8”; 76° 13’ 9”. The pooled fluid on the pad surface was reddish/pink in color, indicative of diesel fuel. I also observed a rainbow colored sheen in a puddle of water nearby the pooled fluid. Sorbents pads used to control and contain the release remained in place. The location of the release and sheen observed was in the southeast section of the pad in between (2) mud pumps not stored on containment and the oil based mud tanks. the total amount of diesel fuel released to the pad surface for (2) separate releases was approximately (3) gallons. |
− | |||
|- | |- | ||
+ | | 2360118 | ||
+ | | Primary Facility | ||
+ | | 04/02/2015 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | There was no activity at the site during the inspection. The secondary containment used during hydraulic fracturing operations remains on-site. There are no frac tanks on-site. I recorded (2) milliSiemens/cm³ conductivity in pad surface water in front of the containment at N-41° 34' 10"; W-76° 13" 7'. Conductivity readings in water on containment were less than (1) ms/cm³. Conductivity readings ranged between (2-3.3) ms/cm³ in water at the end and below the diversion swale/rock-lined ditch below the fill slope of the pad at N- 41.57006°; W-076.21923° and in water just below a culvert in the diversion swale/rock-lined ditch at N- 41.56949°; W-076.21852°. Conductivity readings were less than (1) ms/cm³ in water accumulated next to filter sock below a rock spreader at in a rock-lined ditch at N-41.565958°; W-076.21847°. I also observed some trash on containment. | ||
|- | |- | ||
− | | | + | | 2360151 |
− | | | + | | Primary Facility |
− | | | + | | 04/07/2015 |
− | | | + | | Follow-up Inspection |
− | | | + | | No Violations Noted |
− | | | + | | I recorded (1) milliSiemens/cm³ conductivity in pad surface water in front of the containment at N-41° 34' 10"; W-76° 13" 7'. Conductivity readings in water on containment were less than (1) ms/cm³. Conductivity readings ranged between (2-3.3) ms/cm³ in water at the end and below the diversion swale/rock-lined ditch below the fill slope of the pad at N- 41.57006°; W-076.21923° and in water just below a culvert in the diversion swale/rock-lined ditch at N- 41.56949°; W-076.21852°. I collected a water sample in the diversion swale at the first co-ordinates listed above in the inspection using the PADEP Bureau of Laboratories Standard Analysis Code 046. Conductivity readings were less than (1) ms/cm³ in water accumulated next to compost filter sock below a rock spreader in a rock-lined ditch near the access road and pad entrance at N-41.565958°; W-076.21847°, where I also collected a water sample using SAC 046. |
− | |||
|- | |- | ||
+ | | 2558250 | ||
+ | | Primary Facility | ||
+ | | 2017-02-02 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | Routine inspection conducted to assess general site conditions. No Chesapeake representatives were present. | ||
+ | |||
+ | Vegetative cover on site is greater than 70%, and temporary erosion and sediment control BMPs are still in place. No evidence of accelerated erosion or sedimentation was observed. | ||
+ | |||
+ | A 2-year extension of time for restoring the well site was approved by the Department on 09/17/2015. The post-construction stormwater management BMPs required as part of the extension approval have been installed. | ||
+ | |||
+ | No violations were cited during this inspection. | ||
|- | |- | ||
− | | | + | | 2617828 |
− | | | + | | Primary Facility |
− | | | + | | 2017-07-21 |
− | + | | Routine/Complete Inspection | |
− | | | + | | No Violations Noted |
− | | | + | | The 6H well is being fracked at the 12th stage. The 1H has the coil tubing down hole at this time. FTS is performing the frack. No site security or check point.No leaks detected from equipment. Secondary containment nearly empty of all water. |
− | | | ||
|- | |- | ||
+ | | 2702809 | ||
+ | | Primary Facility | ||
+ | | 2018-03-08 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | Arrived at 1:30. Weather: cloudy threat of snow. Six wellson a six slot set up. Four wells are in production: 1H, 5H, 2H, and 6H. Two wells appear to be TD'ed but not completed. No violations were observed at the time of my inspection. | ||
|- | |- | ||
− | | | + | | 2814588 |
− | | | + | | Primary Facility |
− | | | + | | 2018-12-12 |
− | | | + | | Routine/Complete Inspection |
− | | | + | | No Violations Noted |
− | | | + | | Arrived onsite for a routine inspection at 12:45; the weather was ~30°F and calm. |
− | + | ||
+ | There were 4 active wells and 2 regulatory inactive wells onsite. All well cellars were filled with water; no bubbling was observed. There were also 4 GPUs, 4 sand separators, and 2 produce water tanks onsite and in secondary containment. | ||
+ | |||
+ | Overall, the site was greater than 70% vegetative cover. No E&S issues were observed. There were some sections of filter still around the pad (Photos #1, 2). There was also a section of hose on the pad surface that may or may not be needed for production (Photo #3). | ||
+ | |||
+ | According to Department records a restoration extension request was returned on 9/18/17 due PCSM calculations done for a reduced pad size, however the pad remained at its full size. It also appears that the ESCGP for this pad expired on 11/25/18. | ||
+ | |||
+ | No violations noted. | ||
|- | |- | ||
+ | |} | ||
+ | <!--==== Violations Commited ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Inspection ID | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Violation Date | ||
+ | !scope="col" | Date Resolved | ||
+ | !scope="col" | Violation Code | ||
+ | !scope="col" | Violation Type | ||
+ | !scope="col" | Violation Comments | ||
|- | |- | ||
− | | | + | |}--> |
− | | | + | <!--==== Penalties Applied ==== |
− | | | + | {| class="wikitable sortable" width="95%" |
− | | | + | !scope="col" | Violation ID |
− | | | + | !scope="col" | Penalty ID |
− | | | + | !scope="col" | Penalty Code |
− | | | + | !scope="col" | Penalty Status |
+ | !scope="col" | Penalty Date | ||
+ | !scope="col" | Enforcement Date | ||
+ | !scope="col" | Penalty Amount | ||
+ | !scope="col" | Amount Collected | ||
|- | |- | ||
+ | |}--> | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =Oil and Gas Compliance Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
|- | |- | ||
− | | | + | | 1 |
− | | | + | | 02/06/2015 |
− | | | + | | 02/13/2015 |
− | | | + | | style="text-align: right;" | 7617 |
− | | | + | | style="text-align: right;" | 5,488,730.0 |
− | | | + | | style="text-align: right;" | 467380 |
− | | | ||
|- | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
|- | |- | ||
− | | | + | |- valign="top" |
+ | | rowspan="28"| 1 | ||
+ | | rowspan="2"| WFR-66LC | ||
+ | | rowspan="2"| WEATHERFORD | ||
+ | | rowspan="2"| Friction Reducer | ||
| Petroleum Distillate Hydrotreated Light | | Petroleum Distillate Hydrotreated Light | ||
− | |||
− | |||
− | |||
| 064742-47-8 | | 064742-47-8 | ||
− | | | + | | style="text-align: right;" | 40 |
+ | | style="text-align: right;" | 0.00698 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Sodium Chloride | ||
+ | | 007647-14-5 | ||
+ | | style="text-align: right;" | 20 | ||
+ | | style="text-align: right;" | 0.00349 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Recycled Produced Water | ||
+ | | rowspan="1"| CHESAPEAKE ENERGY | ||
+ | | rowspan="1"| Carrier/Base Fluid | ||
+ | | Water | ||
+ | | 007732-18-5 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 6.03862 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="5"| WAI-251LC, WFR-61LA, WFR-66LC, WIC-641L |
− | | | + | | rowspan="5"| WEATHERFORD |
− | | | + | | rowspan="5"| Corrosion Inhibitor, Friction Reducer, Iron Control Agent |
− | | | + | | Proprietary Alcohol |
| TRADE SECRET | | TRADE SECRET | ||
− | | | + | | style="text-align: right;" | 0 |
− | |- | + | | style="text-align: right;" | 0.00053 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| Water | | Water | ||
− | |||
− | |||
− | |||
| 007732-18-5 | | 007732-18-5 | ||
− | | | + | | style="text-align: right;" | 0 |
+ | | style="text-align: right;" | 0.0064 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | | Proprietary Friction Reducer Additive (WFR-61LA) | ||
+ | | TRADE SECRET | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.04736 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | Proprietary Ethoxylated Nonylphenol | ||
+ | | TRADE SECRET | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00053 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | |||
| Non-MSDS Components Not Provided by Supplier | | Non-MSDS Components Not Provided by Supplier | ||
− | |||
− | |||
− | |||
| NOT PROVIDED | | NOT PROVIDED | ||
− | | | + | | style="text-align: right;" | 0 |
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="8"| WAI-251LC | ||
+ | | rowspan="8"| WEATHERFORD | ||
+ | | rowspan="8"| Corrosion Inhibitor | ||
+ | | Tar bases, quinoline derivs, benzyl chloride-qauternized | ||
+ | | 072480-70-7 | ||
+ | | style="text-align: right;" | 13 | ||
+ | | style="text-align: right;" | 0.0002 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | Dimethyl Formamide |
− | | | + | | 000068-12-2 |
− | | | + | | style="text-align: right;" | 40 |
− | | | + | | style="text-align: right;" | 0.00062 |
− | | | + | | style="text-align: right;" | 0 |
− | | | ||
− | | | ||
|- | |- | ||
+ | | 2-Butoxyethanol (Ethylene Glycol Monobutyl Ether) | ||
+ | | 000111-76-2 | ||
+ | | style="text-align: right;" | 7 | ||
+ | | style="text-align: right;" | 0.00011 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | Ethylene Glycol |
− | | | + | | 000107-21-1 |
− | | | + | | style="text-align: right;" | 60 |
− | | | + | | style="text-align: right;" | 0.00092 |
− | | | + | | style="text-align: right;" | 0 |
− | | | ||
− | | | ||
|- | |- | ||
+ | | Branched-Ethoxylated Nonyl Phenol (Branched-Nonyl Phenol Ethoxylate) | ||
+ | | 068412-54-4 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00015 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | Isopropanol (Isopropyl Alcohol, Propan-2-ol) |
− | | | + | | 000067-63-0 |
− | + | | style="text-align: right;" | 7 | |
− | | | + | | style="text-align: right;" | 0.00011 |
− | | | + | | style="text-align: right;" | 0 |
− | | | ||
− | | | ||
|- | |- | ||
+ | | Cinnamaldehyde | ||
+ | | 000104-55-2 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00015 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | Triethyl Phosphate |
− | | | + | | 000078-40-0 |
− | + | | style="text-align: right;" | 7 | |
− | | | + | | style="text-align: right;" | 0.00011 |
− | | | + | | style="text-align: right;" | 0 |
− | | | ||
− | | | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="4"| WFR-61LA | ||
+ | | rowspan="4"| WEATHERFORD | ||
+ | | rowspan="4"| Friction Reducer | ||
+ | | Alcohols ethoxylated C12-16 | ||
+ | | 068551-12-2 | ||
+ | | style="text-align: right;" | 7 | ||
+ | | style="text-align: right;" | 0.00375 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | Quaternary Ammonium Chloride (Ammonium Chloride) |
− | | | + | | 012125-02-9 |
− | | | + | | style="text-align: right;" | 7 |
− | | | + | | style="text-align: right;" | 0.00375 |
− | | | + | | style="text-align: right;" | 0 |
− | | | ||
− | | | ||
|- | |- | ||
+ | | Sodium Chloride | ||
+ | | 007647-14-5 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00535 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | Petroleum Distillate Hydrotreated Light |
− | | | + | | 064742-47-8 |
− | | | + | | style="text-align: right;" | 40 |
− | | | + | | style="text-align: right;" | 0.0214 |
− | | | + | | style="text-align: right;" | 0 |
− | | | ||
− | | | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| TS-15 | ||
+ | | rowspan="1"| TERRA SERVICES | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Proprietary Sodium Polycarboxylate | ||
+ | | TRADE SECRET | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00874 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="1"| Northern White Sand |
− | | | + | | rowspan="1"| WEATHERFORD |
− | | | + | | rowspan="1"| Proppant - Natural |
− | | | + | | Crystalline Silica (Quartz Sand, Silicon Dioxide) |
− | | | + | | 014808-60-7 |
− | | | + | | style="text-align: right;" | 100 |
+ | | style="text-align: right;" | 8.14319 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| ACID, HYDROCHLORIC, 7.5 PCT | ||
+ | | rowspan="2"| WEATHERFORD | ||
+ | | rowspan="2"| Acid | ||
+ | | Water | ||
+ | | 007732-18-5 | ||
+ | | style="text-align: right;" | 93 | ||
+ | | style="text-align: right;" | 0.69167 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | 0 | + | | Hydrochloric Acid |
− | | | + | | 007647-01-0 |
− | | | + | | style="text-align: right;" | 8 |
− | | | + | | style="text-align: right;" | 0.05608 |
− | | | + | | style="text-align: right;" | 0 |
− | | | ||
− | | | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Chlorine Dioxide | ||
+ | | rowspan="1"| TERRA SERVICES | ||
+ | | rowspan="1"| Anti-Bacterial Agent | ||
+ | | Chlorine Dioxide | ||
+ | | 010049-04-4 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00978 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="1"| Fresh Water |
− | | | + | | rowspan="1"| CHESAPEAKE ENERGY |
− | | | + | | rowspan="1"| Carrier/Base Fluid |
− | | | + | | Water |
− | | | + | | 007732-18-5 |
− | | | + | | style="text-align: right;" | 100 |
+ | | style="text-align: right;" | 76.714 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| WIC-641L | ||
+ | | rowspan="1"| WEATHERFORD | ||
+ | | rowspan="1"| Iron Control Agent | ||
+ | | Citric Acid | ||
+ | | 000077-92-9 | ||
+ | | style="text-align: right;" | 70 | ||
+ | | style="text-align: right;" | 0.00624 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="1"| 100 Mesh Sand |
− | | | + | | rowspan="1"| WEATHERFORD |
− | | | + | | rowspan="1"| Proppant - Natural |
− | | | + | | Crystalline Silica (Quartz Sand, Silicon Dioxide) |
− | | | + | | 014808-60-7 |
− | | | + | | style="text-align: right;" | 100 |
+ | | style="text-align: right;" | 8.2565 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
|} | |} | ||
− | For data sources see<ref>{{cite web | title = FracFocus | + | For data sources see<ref>{{cite web |
− | == References == | + | | title =FracFocus Fracking Chemicals Database |
− | + | | date = 2019-04-02 | |
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
+ | ==References== | ||
+ | <references/> | ||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
− | [[Category:Wells]] | + | [[Category:Pennsylvania Wells]] |
+ | [[Category:FracFocus]] |
Well ID: 37-015-22832 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.569228,"lon":-76.219367,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Bradford | |
Municipality: Wilmot Township | |
Operator Name: CHESAPEAKE APPALACHIA LLC | |
Well Pad ID: 150854 | |
Farm/Lease Name: BIM BRA 2H | |
License Status: Active | |
Spud Date: 07/07/2014 | |
Permit Date: 2/20/2014 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.569228 | |
Longitude: -76.219367 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | CHESAPEAKE APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CHESAPEAKE APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | CHESAPEAKE APPALACHIA LLC | 1,945,667.00 | 132 | 0.00 | 0 | 0.00 | 0 |
2017 | CHESAPEAKE APPALACHIA LLC | 3,297,726.00 | 290 | 0.00 | 0 | 0.00 | 0 |
2018 | CHESAPEAKE APPALACHIA LLC | 1,853,854.00 | 362 | 0.00 | 0 | 0.00 | 0 |
2019 | CHESAPEAKE APPALACHIA LLC | 371,403.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2014-2 | Drill Cuttings (in Tons) | 431.29 Tons | LANDFILL | 8-0728-0004/013 |
2014-2 | Drill Cuttings (in Tons) | 432.99 Tons | LANDFILL | 8-4630-00010/00 |
2014-2 | Drill Cuttings (in Tons) | 216.50 Tons | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR097R017 |
2015-1 | Drill Cuttings (in Tons) | 5.13 Tons | LANDFILL | THR029 |
2016-1 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 17.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2016-1 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 51.59 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC008 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 220.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC008 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 216.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 514.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-2 | Synthetic Liner Materials (in Tons) RWC 806 | 1.79 Tons | LANDFILL | 8-0728-0004/013 |
2017-02 | Produced Fluid (in Barrels) RWC 802 | 103.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-03 | Produced Fluid (in Barrels) RWC 802 | 354.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-04 | Produced Fluid (in Barrels) RWC 802 | 218.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017-05 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 18.40 Bbl | REUSE (AT WELL PAD) | |
2017-05 | Produced Fluid (in Barrels) RWC 802 | 123.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-06 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 16.70 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC008 |
2017-06 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 55.20 Bbl | REUSE (AT WELL PAD) | |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 307.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC008 |
2017-07 | Produced Fluid (in Barrels) RWC 802 | 650.00 Bbl | REUSE (AT WELL PAD) | |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 302.60 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC008 |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 872.00 Bbl | REUSE (AT WELL PAD) | |
2017-09 | Produced Fluid (in Barrels) RWC 802 | 131.20 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC008 |
2017-09 | Produced Fluid (in Barrels) RWC 802 | 309.10 Bbl | REUSE (AT WELL PAD) | |
2017-09 | Synthetic Liner Materials (in Tons) RWC 806 | 0.60 Tons | CENT WASTE TRT FAC NPDES DISCHARGE | PAG034815 |
2017-09 | Waste Water Treatment Sludge (in Tons) RWC 804 | 6.20 Tons | LANDFILL | 301626 |
2017-11 | Produced Fluid (in Barrels) RWC 802 | 219.30 Bbl | REUSE (AT WELL PAD) | |
2017-12 | Produced Fluid (in Barrels) RWC 802 | 27.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017-12 | Produced Fluid (in Barrels) RWC 802 | 135.90 Bbl | REUSE (AT WELL PAD) | |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 26.80 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 27.80 Bbl | REUSE (AT WELL PAD) | |
2018-01 | Waste Water Treatment Sludge (in Tons) RWC 804 | 0.70 Tons | LANDFILL | 301626 |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 20.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC008 |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 54.30 Bbl | REUSE (AT WELL PAD) | |
2018-03 | Waste Water Treatment Sludge (in Tons) RWC 804 | 0.60 Tons | LANDFILL | 301626 |
2018-05 | Produced Fluid (in Barrels) RWC 802 | 54.30 Bbl | REUSE (AT WELL PAD) | |
2018-06 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 18.40 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC008 |
2018-06 | Produced Fluid (in Barrels) RWC 802 | 27.50 Bbl | REUSE (AT WELL PAD) | |
2018-06 | Synthetic Liner Materials (in Tons) RWC 806 | 0.90 Tons | CENT WASTE TRT FAC NPDES DISCHARGE | PAG034815 |
2018-07 | Produced Fluid (in Barrels) RWC 802 | 27.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018-07 | Produced Fluid (in Barrels) RWC 802 | 54.30 Bbl | REUSE (AT WELL PAD) | |
2018-09 | Produced Fluid (in Barrels) RWC 802 | 54.10 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2283444 | Primary Facility | 06/27/2014 | Preoperation Inspection | No Violations Noted | |
2308484 | Primary Facility | 09/30/2014 | Routine/Complete Inspection | No Violations Noted | |
2324842 | Primary Facility | 11/24/2014 | Routine/Complete Inspection | No Violations Noted | While in the process of surveying the containment and equipment and evaluation site conditions, I observed the evidence of a petroleum product release on the ground surface of the Pad at 41° 34’ 8”; 76° 13’ 9”. The pooled fluid on the pad surface was reddish/pink in color, indicative of diesel fuel. I also observed a rainbow colored sheen in a puddle of water nearby the pooled fluid. Sorbents pads used to control and contain the release remained in place. The location of the release and sheen observed was in the southeast section of the pad in between (2) mud pumps not stored on containment and the oil based mud tanks. the total amount of diesel fuel released to the pad surface for (2) separate releases was approximately (3) gallons. |
2360118 | Primary Facility | 04/02/2015 | Routine/Complete Inspection | No Violations Noted | There was no activity at the site during the inspection. The secondary containment used during hydraulic fracturing operations remains on-site. There are no frac tanks on-site. I recorded (2) milliSiemens/cm³ conductivity in pad surface water in front of the containment at N-41° 34' 10"; W-76° 13" 7'. Conductivity readings in water on containment were less than (1) ms/cm³. Conductivity readings ranged between (2-3.3) ms/cm³ in water at the end and below the diversion swale/rock-lined ditch below the fill slope of the pad at N- 41.57006°; W-076.21923° and in water just below a culvert in the diversion swale/rock-lined ditch at N- 41.56949°; W-076.21852°. Conductivity readings were less than (1) ms/cm³ in water accumulated next to filter sock below a rock spreader at in a rock-lined ditch at N-41.565958°; W-076.21847°. I also observed some trash on containment. |
2360151 | Primary Facility | 04/07/2015 | Follow-up Inspection | No Violations Noted | I recorded (1) milliSiemens/cm³ conductivity in pad surface water in front of the containment at N-41° 34' 10"; W-76° 13" 7'. Conductivity readings in water on containment were less than (1) ms/cm³. Conductivity readings ranged between (2-3.3) ms/cm³ in water at the end and below the diversion swale/rock-lined ditch below the fill slope of the pad at N- 41.57006°; W-076.21923° and in water just below a culvert in the diversion swale/rock-lined ditch at N- 41.56949°; W-076.21852°. I collected a water sample in the diversion swale at the first co-ordinates listed above in the inspection using the PADEP Bureau of Laboratories Standard Analysis Code 046. Conductivity readings were less than (1) ms/cm³ in water accumulated next to compost filter sock below a rock spreader in a rock-lined ditch near the access road and pad entrance at N-41.565958°; W-076.21847°, where I also collected a water sample using SAC 046. |
2558250 | Primary Facility | 2017-02-02 | Routine/Complete Inspection | No Violations Noted | Routine inspection conducted to assess general site conditions. No Chesapeake representatives were present.
Vegetative cover on site is greater than 70%, and temporary erosion and sediment control BMPs are still in place. No evidence of accelerated erosion or sedimentation was observed. A 2-year extension of time for restoring the well site was approved by the Department on 09/17/2015. The post-construction stormwater management BMPs required as part of the extension approval have been installed. No violations were cited during this inspection. |
2617828 | Primary Facility | 2017-07-21 | Routine/Complete Inspection | No Violations Noted | The 6H well is being fracked at the 12th stage. The 1H has the coil tubing down hole at this time. FTS is performing the frack. No site security or check point.No leaks detected from equipment. Secondary containment nearly empty of all water. |
2702809 | Primary Facility | 2018-03-08 | Routine/Complete Inspection | No Violations Noted | Arrived at 1:30. Weather: cloudy threat of snow. Six wellson a six slot set up. Four wells are in production: 1H, 5H, 2H, and 6H. Two wells appear to be TD'ed but not completed. No violations were observed at the time of my inspection. |
2814588 | Primary Facility | 2018-12-12 | Routine/Complete Inspection | No Violations Noted | Arrived onsite for a routine inspection at 12:45; the weather was ~30°F and calm.
There were 4 active wells and 2 regulatory inactive wells onsite. All well cellars were filled with water; no bubbling was observed. There were also 4 GPUs, 4 sand separators, and 2 produce water tanks onsite and in secondary containment. Overall, the site was greater than 70% vegetative cover. No E&S issues were observed. There were some sections of filter still around the pad (Photos #1, 2). There was also a section of hose on the pad surface that may or may not be needed for production (Photo #3). According to Department records a restoration extension request was returned on 9/18/17 due PCSM calculations done for a reduced pad size, however the pad remained at its full size. It also appears that the ESCGP for this pad expired on 11/25/18. No violations noted. |
For data sources see[6]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 02/06/2015 | 02/13/2015 | 7617 | 5,488,730.0 | 467380 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | WFR-66LC | WEATHERFORD | Friction Reducer | Petroleum Distillate Hydrotreated Light | 064742-47-8 | 40 | 0.00698 | 0 |
Sodium Chloride | 007647-14-5 | 20 | 0.00349 | 0 | ||||
Recycled Produced Water | CHESAPEAKE ENERGY | Carrier/Base Fluid | Water | 007732-18-5 | 100 | 6.03862 | 0 | |
WAI-251LC, WFR-61LA, WFR-66LC, WIC-641L | WEATHERFORD | Corrosion Inhibitor, Friction Reducer, Iron Control Agent | Proprietary Alcohol | TRADE SECRET | 0 | 0.00053 | 0 | |
Water | 007732-18-5 | 0 | 0.0064 | 0 | ||||
Proprietary Friction Reducer Additive (WFR-61LA) | TRADE SECRET | 0 | 0.04736 | 0 | ||||
Proprietary Ethoxylated Nonylphenol | TRADE SECRET | 0 | 0.00053 | 0 | ||||
Non-MSDS Components Not Provided by Supplier | NOT PROVIDED | 0 | 0 | 0 | ||||
WAI-251LC | WEATHERFORD | Corrosion Inhibitor | Tar bases, quinoline derivs, benzyl chloride-qauternized | 072480-70-7 | 13 | 0.0002 | 0 | |
Dimethyl Formamide | 000068-12-2 | 40 | 0.00062 | 0 | ||||
2-Butoxyethanol (Ethylene Glycol Monobutyl Ether) | 000111-76-2 | 7 | 0.00011 | 0 | ||||
Ethylene Glycol | 000107-21-1 | 60 | 0.00092 | 0 | ||||
Branched-Ethoxylated Nonyl Phenol (Branched-Nonyl Phenol Ethoxylate) | 068412-54-4 | 10 | 0.00015 | 0 | ||||
Isopropanol (Isopropyl Alcohol, Propan-2-ol) | 000067-63-0 | 7 | 0.00011 | 0 | ||||
Cinnamaldehyde | 000104-55-2 | 10 | 0.00015 | 0 | ||||
Triethyl Phosphate | 000078-40-0 | 7 | 0.00011 | 0 | ||||
WFR-61LA | WEATHERFORD | Friction Reducer | Alcohols ethoxylated C12-16 | 068551-12-2 | 7 | 0.00375 | 0 | |
Quaternary Ammonium Chloride (Ammonium Chloride) | 012125-02-9 | 7 | 0.00375 | 0 | ||||
Sodium Chloride | 007647-14-5 | 10 | 0.00535 | 0 | ||||
Petroleum Distillate Hydrotreated Light | 064742-47-8 | 40 | 0.0214 | 0 | ||||
TS-15 | TERRA SERVICES | Scale Inhibitor | Proprietary Sodium Polycarboxylate | TRADE SECRET | 100 | 0.00874 | 0 | |
Northern White Sand | WEATHERFORD | Proppant - Natural | Crystalline Silica (Quartz Sand, Silicon Dioxide) | 014808-60-7 | 100 | 8.14319 | 0 | |
ACID, HYDROCHLORIC, 7.5 PCT | WEATHERFORD | Acid | Water | 007732-18-5 | 93 | 0.69167 | 0 | |
Hydrochloric Acid | 007647-01-0 | 8 | 0.05608 | 0 | ||||
Chlorine Dioxide | TERRA SERVICES | Anti-Bacterial Agent | Chlorine Dioxide | 010049-04-4 | 100 | 0.00978 | 0 | |
Fresh Water | CHESAPEAKE ENERGY | Carrier/Base Fluid | Water | 007732-18-5 | 100 | 76.714 | 0 | |
WIC-641L | WEATHERFORD | Iron Control Agent | Citric Acid | 000077-92-9 | 70 | 0.00624 | 0 | |
100 Mesh Sand | WEATHERFORD | Proppant - Natural | Crystalline Silica (Quartz Sand, Silicon Dioxide) | 014808-60-7 | 100 | 8.2565 | 0 |
For data sources see[7]