X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-035-61263"

m
m
Line 1: Line 1:
__TOC__
+
__TOC__
 
== Well Details ==
 
== Well Details ==
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-035-61263
 
| Well ID: 34-035-61263
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.5260502, -81.40802021 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.525908069, -81.40789646 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Cuyahoga County, Ohio|Cuyahoga]]
+
| Country: United States
 +
|-
 +
| State: Ohio
 +
|-
 +
| County: [[Cuyahoga_County,_Ohio|Cuyahoga]]
 
|-
 
|-
 
| Municipality:  
 
| Municipality:  
Line 13: Line 17:
 
| Well Pad ID:  
 
| Well Pad ID:  
 
|-
 
|-
| Farm/Lease Name:  
+
| Farm/Lease Name: MLAKER, KATHERINE
 
|-
 
|-
| First Permit Date:  
+
| License Status: Orphan Well - Ready
 
|-
 
|-
| Last Permit Date:  
+
| License Date: 2010-05-01
 
|-
 
|-
 
| Spud Date:  
 
| Spud Date:  
 
|-
 
|-
| Unconventional: No
+
| Spud Drilling Contractor:
 +
|-
 +
| Final Drill Date:
 +
|-
 +
| Well Total Depth:  
 
|-
 
|-
 
| Configuration: Vertical
 
| Configuration: Vertical
 
|-
 
|-
| Well Status:  
+
| Latitude: 41.525908069
 
|-
 
|-
| Violations: 0
+
| Longitude: -81.40789646
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Well Status
 +
!scope="col" style="width: 15%;text-align: center"| Well Status Date
 +
!scope="col" style="text-align: center"| Comment
 
|-
 
|-
| Latitude: 41.5260502
+
| Changed to  Orphan Well Ready
 +
| 2010-05-01
 +
| Changed Well To Orphan Ready
 
|-
 
|-
| Longitude: -81.40802021
+
| Well Added to System
 +
| 2013-05-21
 +
| WELL WAS ADDED TO SYSTEM ON  5/21/2013 10:35:28 AM
 +
|-
 +
| Record Last Modified
 +
| 2019-03-25
 +
| RBDMS Rec
 +
WELL IN SQUARE VAULT (3'X3'). WELLHEAD IS A 2 BOLT WITH MISSING CAP AND 2" TUBING WITH VALVE ON SIDE.  WELL IS 40' TO SOUTH OF DRIVE.
 +
I&O CN 2010 05 028. UPDATED LOCATION PER DOGRM SURVEYOR 11/27/18-ALE
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well and WellHistry Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
<!--== Perforation Treatments ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Perforation Date
 +
!scope="col" style="text-align: center"| Interval Top (ft)
 +
!scope="col" style="text-align: center"| Interval Base (ft)
 +
!scope="col" style="text-align: center"| Number of Shots
 +
|-
 +
|}-->
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Job Start Date
 +
!scope="col" style="text-align: center"| Job End Date
 +
!scope="col" style="text-align: center"| True Vertical Depth (ft)
 +
!scope="col" style="text-align: center"| Total Water Volume (gal)
 +
!scope="col" style="text-align: center"| Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" style="width: 100%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Trade Name
 +
!scope="col" style="text-align: center"| Supplier
 +
!scope="col" style="text-align: center"| Purpose
 +
!scope="col" style="text-align: center"| Ingredient Name
 +
!scope="col" style="white-space: nowrap;text-align: center"| CAS Number
 +
!scope="col" style="text-align: center"| Additive Percentage by Mass
 +
!scope="col" style="text-align: center"| Job Percentage by Mass
 +
!scope="col" style="text-align: center"| Mass Used (lb)
 +
|-
 +
|}-->
 +
<!--== Stimulations Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Stimulation Date
 +
!scope="col" style="text-align: center"| Chemical Agent
 +
!scope="col" style="text-align: center"| Chemical Agent Concentration (%)
 +
!scope="col" style="text-align: center"| Fracking Fluid Volume
 +
!scope="col" style="text-align: center"| Mass of Proppant Used (lb)
 +
!scope="col" style="text-align: center"| Fracking Company
 +
!scope="col" style="text-align: center"| Comments
 +
|-
 +
|}-->
 +
<!--== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Gas Quantity (mcf)
 +
!scope="col" style="text-align: center"| Oil Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
|}-->
 +
<!--== Waste Data ==
 +
{| class="wikitable sortable"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Waste Type
 +
!scope="col" style="text-align: center"| Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
|}-->
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" style="text-align: center"| Inspection ID
!scope="col" | DATE
+
!scope="col" style="text-align: center"| Inspection Date
!scope="col" | DESCRIPTION
+
!scope="col" style="text-align: center"| Inspection Type
!scope="col" | COMMENT
+
!scope="col" style="text-align: center"| Inspection Result
!scope="col" | VIOLATION ID
+
!scope="col" style="text-align: center"| Inspection Comments
!scope="col" | VIOLATION CODE
+
|-
!scope="col" | VIOLATION COMMENT
+
| 0001101070
 +
| 2015-10-15
 +
| Orphan
 +
| No Violations
 +
| Field review of location to be familiar with site and location.  Gathered 3 pictures and confirmed GPS readings.  Confirmed that well is not presently leaking, utilizing Sperian Gas Meter and recording 0% LEL.
 +
|-
 +
| 0221388674
 +
| 2017-03-07
 +
| Orphan
 +
| No Violations
 +
| On location today with Terry Whitehair and Vicki Bunting from Emergency Response Section for technical review of location.  Contacted Mr. Mlakar by phone yesterday, and e-mailed him a Right of Entry and Landowner Selection form.  He is to fill out and return to office via e-mail of regular mail.  Safety SectionTechnical Review is complete.
 
|-
 
|-
 
| 1378740839
 
| 1378740839
 
| 2013-08-22
 
| 2013-08-22
|  
+
| Orphan
 +
| No Violations
 
| On this inspection I gathered additional information for the site location sketch, took additional pictures and confirmed GPS coordinated.
 
| On this inspection I gathered additional information for the site location sketch, took additional pictures and confirmed GPS coordinated.
|  
+
|-
|  
+
| 1488827479
|  
+
| 2017-02-23
 +
| Orphan
 +
| No Violations
 +
| Went to location to deliver Right Of Entry and Landowner Selection Forms forms to landowner.  No one at home, placed papers in mailbox.
 +
|-
 +
| 1489760917
 +
| 2017-03-16
 +
| Orphan
 +
| No Violations
 +
| On location today to pump the water from within the 3 X 3 vault, examine the existing piping and attempt to determine open annular space between the tubing and casing.  After removing water from the vault it was determined that there is open annular space to the west and northwest of the tubing.  Due to the fact that there was an inordinate amount of sludge in the bottom of the vault, the total amount of fluid could not be removed, and the casing surrounding the tubing was not visible.
 +
|-
 +
| 2081958137
 +
| 2015-08-06
 +
| Orphan
 +
| No Violations
 +
| I inspected this well as an update on current condition and status. The well is located along the private entrance drive of a residence. Areas surrounding the well consist of well-maintained turf grass. The well is accessible from the house driveway. The well is located in a 30 square concrete and masonry vault structure with a metal lid. The well is located in the vault, below grade level. The vault is full of water and all of the well elements are submerged. The wellhead is not discernible under the water.  I did not detect gas odors or meter-detected gas near the well. There is no visible gas coming from the submerged well. The vault will have to be drained to make a more detailed inspection.
 
|-
 
|-
 
|}
 
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Violation ID
 +
!scope="col" style="text-align: center"| Violation Date
 +
!scope="col" style="text-align: center"| Violation Code
 +
!scope="col" style="text-align: center"| Violation Comments
 +
|-
 +
|}-->
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Ohio Department of Natural Resources RBDMS
+
  | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
  | publisher = [http://oilandgas.ohiodnr.gov/]
+
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2015-06-19
+
  | date = 2019-05-07
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection
+
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2015-06-20 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
== References ==
+
==References==
{{reflist}}
+
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Ohio Wells]]

Revision as of 17:27, 24 July 2019

Well Details

Well ID: 34-035-61263
Loading map...
Country: United States
State: Ohio
County: Cuyahoga
Municipality:
Operator Name: HISTORIC OWNER
Well Pad ID:
Farm/Lease Name: MLAKER, KATHERINE
License Status: Orphan Well - Ready
License Date: 2010-05-01
Spud Date:
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 41.525908069
Longitude: -81.40789646

For data sources see[1]

Well History

Well Status Well Status Date Comment
Changed to Orphan Well Ready 2010-05-01 Changed Well To Orphan Ready
Well Added to System 2013-05-21 WELL WAS ADDED TO SYSTEM ON 5/21/2013 10:35:28 AM
Record Last Modified 2019-03-25 RBDMS Rec

WELL IN SQUARE VAULT (3'X3'). WELLHEAD IS A 2 BOLT WITH MISSING CAP AND 2" TUBING WITH VALVE ON SIDE. WELL IS 40' TO SOUTH OF DRIVE. I&O CN 2010 05 028. UPDATED LOCATION PER DOGRM SURVEYOR 11/27/18-ALE

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0001101070 2015-10-15 Orphan No Violations Field review of location to be familiar with site and location. Gathered 3 pictures and confirmed GPS readings. Confirmed that well is not presently leaking, utilizing Sperian Gas Meter and recording 0% LEL.
0221388674 2017-03-07 Orphan No Violations On location today with Terry Whitehair and Vicki Bunting from Emergency Response Section for technical review of location. Contacted Mr. Mlakar by phone yesterday, and e-mailed him a Right of Entry and Landowner Selection form. He is to fill out and return to office via e-mail of regular mail. Safety SectionTechnical Review is complete.
1378740839 2013-08-22 Orphan No Violations On this inspection I gathered additional information for the site location sketch, took additional pictures and confirmed GPS coordinated.
1488827479 2017-02-23 Orphan No Violations Went to location to deliver Right Of Entry and Landowner Selection Forms forms to landowner. No one at home, placed papers in mailbox.
1489760917 2017-03-16 Orphan No Violations On location today to pump the water from within the 3 X 3 vault, examine the existing piping and attempt to determine open annular space between the tubing and casing. After removing water from the vault it was determined that there is open annular space to the west and northwest of the tubing. Due to the fact that there was an inordinate amount of sludge in the bottom of the vault, the total amount of fluid could not be removed, and the casing surrounding the tubing was not visible.
2081958137 2015-08-06 Orphan No Violations I inspected this well as an update on current condition and status. The well is located along the private entrance drive of a residence. Areas surrounding the well consist of well-maintained turf grass. The well is accessible from the house driveway. The well is located in a 30 square concrete and masonry vault structure with a metal lid. The well is located in the vault, below grade level. The vault is full of water and all of the well elements are submerged. The wellhead is not discernible under the water. I did not detect gas odors or meter-detected gas near the well. There is no visible gas coming from the submerged well. The vault will have to be drained to make a more detailed inspection.