X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-155-23980"

m
m
Line 1: Line 1:
__TOC__
+
__TOC__
 
== Well Details ==
 
== Well Details ==
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-155-23980
 
| Well ID: 34-155-23980
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.18728244, -80.58948907 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.187225409, -80.58969344 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Trumbull County, Ohio|Trumbull]]
+
| Country: United States
 
|-
 
|-
| Municipality:  
+
| State: Ohio
 +
|-
 +
| County: [[Trumbull_County,_Ohio|Trumbull]]
 +
|-
 +
| Municipality: [[Hubbard,_Ohio|Hubbard]]
 
|-
 
|-
 
| Operator Name: [[PAC DRILLING LLC]]
 
| Operator Name: [[PAC DRILLING LLC]]
Line 13: Line 17:
 
| Well Pad ID:  
 
| Well Pad ID:  
 
|-
 
|-
| Farm/Lease Name:  
+
| Farm/Lease Name: SARISKY
 
|-
 
|-
| First Permit Date:  
+
| License Status: Producing
 
|-
 
|-
| Last Permit Date:  
+
| License Date: 2009-06-04
 
|-
 
|-
 
| Spud Date: 2008-11-18
 
| Spud Date: 2008-11-18
 
|-
 
|-
| Unconventional: No
+
| Spud Drilling Contractor: [[CAPSTAR DRILLING]]
 +
|-
 +
| Final Drill Date: 2008-11-24
 +
|-
 +
| Well Total Depth: 5276 ft
 
|-
 
|-
 
| Configuration: Vertical
 
| Configuration: Vertical
 
|-
 
|-
| Well Status: Producing
+
| Latitude: 41.187225409
 +
|-
 +
| Longitude: -80.58969344
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Well Status
 +
!scope="col" style="width: 15%;text-align: center"| Well Status Date
 +
!scope="col" style="text-align: center"| Comment
 +
|-
 +
| APP
 +
| 2008-11-14
 +
| Proposed Formations:CLINTON/MEDINA, Issued Date:11/14/2008, Expired Date:11/14/2009 6:00:00 AM, Drilling unit acres:46.56, Proposed Well Type:OG, Proposed Well Class:POOL
 +
|-
 +
| Reached Total Depth
 +
| 2008-11-24
 +
 +
|-
 +
| Completion Report Received
 +
| 2009-03-06
 +
 
|-
 
|-
| Violations: 0
+
| Construction Permit Expires
 +
| 2009-11-14
 +
 +
|-
 +
| Record Last Modified
 +
| 2015-09-24
 +
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well and WellHistry Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Perforation Treatments ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Perforation Date
 +
!scope="col" style="text-align: center"| Interval Top (ft)
 +
!scope="col" style="text-align: center"| Interval Base (ft)
 +
!scope="col" style="text-align: center"| Number of Shots
 
|-
 
|-
| Latitude: 41.18728244
+
| 2009-06-04
 +
| style="text-align: right;" | 4972
 +
| style="text-align: right;" | 5050
 +
| style="text-align: right;" | 39
 
|-
 
|-
| Longitude: -80.58948907
+
| 2009-06-04
 +
| style="text-align: right;" | 5132
 +
| style="text-align: right;" | 5136
 +
| style="text-align: right;" | 6
 
|-
 
|-
 
|}
 
|}
== Production Data ==
+
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Perfs Table
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Job Start Date
 +
!scope="col" style="text-align: center"| Job End Date
 +
!scope="col" style="text-align: center"| True Vertical Depth (ft)
 +
!scope="col" style="text-align: center"| Total Water Volume (gal)
 +
!scope="col" style="text-align: center"| Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" style="width: 100%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Trade Name
 +
!scope="col" style="text-align: center"| Supplier
 +
!scope="col" style="text-align: center"| Purpose
 +
!scope="col" style="text-align: center"| Ingredient Name
 +
!scope="col" style="white-space: nowrap;text-align: center"| CAS Number
 +
!scope="col" style="text-align: center"| Additive Percentage by Mass
 +
!scope="col" style="text-align: center"| Job Percentage by Mass
 +
!scope="col" style="text-align: center"| Mass Used (lb)
 +
|-
 +
|}-->
 +
== Stimulations Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" style="text-align: center"| Stimulation Date
!scope="col" | GAS QUANTITY
+
!scope="col" style="text-align: center"| Chemical Agent
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" style="text-align: center"| Chemical Agent Concentration (%)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" style="text-align: center"| Fracking Fluid Volume
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" style="text-align: center"| Mass of Proppant Used (lb)
!scope="col" | OIL QUANTITY
+
!scope="col" style="text-align: center"| Fracking Company
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" style="text-align: center"| Comments
 
|-
 
|-
| 2009-0
 
| style="text-align:right;" | 23725.0
 
 
|  
 
|  
 +
| H2O
 +
| style="text-align: right;" | 20
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 34500
 
|  
 
|  
 
|  
 
|  
| style="text-align:right;" | 506.0
 
|
 
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - tblStimulation Table
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Gas Quantity (mcf)
 +
!scope="col" style="text-align: center"| Oil Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
| 2009
 +
| [[PAC DRILLING LLC]]
 +
| style="text-align: right;" | 23725
 +
| style="text-align: right;" | 506
 +
| style="text-align: right;" | 351
 +
|-
 +
| 2010
 +
| [[PAC DRILLING LLC]]
 +
| style="text-align: right;" | 20250
 +
| style="text-align: right;" | 210
 +
| style="text-align: right;" | 349
 +
|-
 +
| 2011
 +
| [[PAC DRILLING LLC]]
 +
| style="text-align: right;" | 8649
 +
| style="text-align: right;" | 203
 +
| style="text-align: right;" | 335
 +
|-
 +
| 2012
 +
| [[PAC DRILLING LLC]]
 +
| style="text-align: right;" | 4632
 +
| style="text-align: right;" | 166
 +
| style="text-align: right;" | 334
 +
|-
 +
| 2013
 +
| [[PAC DRILLING LLC]]
 +
| style="text-align: right;" | 3414
 +
| style="text-align: right;" | 134
 +
| style="text-align: right;" | 365
 +
|-
 +
| 2014
 +
| [[PAC DRILLING LLC]]
 +
| style="text-align: right;" | 3106
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 360
 +
|-
 +
| 2015
 +
| [[PAC DRILLING LLC]]
 +
| style="text-align: right;" | 3590
 +
| style="text-align: right;" | 90
 +
| style="text-align: right;" | 360
 +
|-
 +
| 2016
 +
| [[PAC DRILLING LLC]]
 +
| style="text-align: right;" | 2600
 +
| style="text-align: right;" | 79
 +
| style="text-align: right;" | 355
 +
|-
 +
| 2017
 +
| [[PAC DRILLING LLC]]
 +
| style="text-align: right;" | 2554
 +
| style="text-align: right;" | 67
 +
| style="text-align: right;" | 356
 +
|-
 +
| 2018
 +
| [[PAC DRILLING LLC]]
 +
| style="text-align: right;" | 2441
 +
| style="text-align: right;" | 146
 +
| style="text-align: right;" | 356
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Production Table - Oil and Gas Data
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
<ref>{{cite web
 +
| title = Combined Production - Oil and Gas Data
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date = 2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Waste Data ==
 +
{| class="wikitable sortable"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Waste Type
 +
!scope="col" style="text-align: center"| Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
| 2009
 +
| [[PAC DRILLING LLC]]
 +
| Brine
 +
| style="text-align: right;" | 50
 +
| style="text-align: right;" | 351
 
|-
 
|-
| 2010-0
+
| 2010
| style="text-align:right;" | 20250.0
+
| [[PAC DRILLING LLC]]
|
+
| Brine
|
+
| style="text-align: right;" | 70
|
+
| style="text-align: right;" | 349
| style="text-align:right;" | 210.0
 
|
 
 
|-
 
|-
 +
| 2011
 +
| [[PAC DRILLING LLC]]
 +
| Brine
 +
| style="text-align: right;" | 40
 +
| style="text-align: right;" | 335
 
|-
 
|-
| 2011-0
+
| 2012
| style="text-align:right;" | 8649.0
+
| [[PAC DRILLING LLC]]
|
+
| Brine
|
+
| style="text-align: right;" | 40
|
+
| style="text-align: right;" | 334
| style="text-align:right;" | 203.0
 
|
 
 
|-
 
|-
 +
| 2013
 +
| [[PAC DRILLING LLC]]
 +
| Brine
 +
| style="text-align: right;" | 57
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 2012-0
+
| 2014
| style="text-align:right;" | 4632.0
+
| [[PAC DRILLING LLC]]
|
+
| Brine
|
+
| style="text-align: right;" | 57
|
+
| style="text-align: right;" | 360
| style="text-align:right;" | 166.0
 
|
 
 
|-
 
|-
 +
| 2015
 +
| [[PAC DRILLING LLC]]
 +
| Brine
 +
| style="text-align: right;" | 37
 +
| style="text-align: right;" | 360
 
|-
 
|-
| 2013-0
+
| 2016
| style="text-align:right;" | 3414.0
+
| [[PAC DRILLING LLC]]
|
+
| Brine
|
+
| style="text-align: right;" | 0
|
+
| style="text-align: right;" | 355
| style="text-align:right;" | 134.0
 
|
 
 
|-
 
|-
 +
| 2017
 +
| [[PAC DRILLING LLC]]
 +
| Brine
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 356
 
|-
 
|-
| 2014-0
+
| 2018
| style="text-align:right;" | 3106.0
+
| [[PAC DRILLING LLC]]
| style="text-align:right;" | 360.0
+
| Brine
|  
+
| style="text-align: right;" | 0
|  
+
| style="text-align: right;" | 356
| style="text-align:right;" | 100.0
 
| style="text-align:right;" | 360.0
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Ohio Department of Natural Resources RBDMS
+
  | title = Risk Based Data Management System - Production Table - Brine Data
  | publisher = [http://oilandgas.ohiodnr.gov/]
+
|publisher = [[Ohio Department of Natural Resources]]
  | date = 2015-06-19
+
  | date =  2019-05-07
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Production
+
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2015-06-20 }}</ref>
+
| accessdate = 2019-05-21 }}</ref>
 +
<ref>{{cite web
 +
| title = Combined Production - Brine Data
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
  | date = 2019-05-07
 +
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
  | accessdate = 2019-05-21 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" style="text-align: center"| Inspection ID
!scope="col" | DATE
+
!scope="col" style="text-align: center"| Inspection Date
!scope="col" | DESCRIPTION
+
!scope="col" style="text-align: center"| Inspection Type
!scope="col" | COMMENT
+
!scope="col" style="text-align: center"| Inspection Result
!scope="col" | VIOLATION ID
+
!scope="col" style="text-align: center"| Inspection Comments
!scope="col" | VIOLATION CODE
+
|-
!scope="col" | VIOLATION COMMENT
+
| 0317875937
 +
| 2016-11-09
 +
| UrbanProduction Wells
 +
| No Violations
 +
 
 +
 
 +
PAC Drilling will:
 +
Install locks on the load lines or remove the valve handles
 +
Install the required safety equipment
 +
 
 +
 
 +
-pressure relief valve
 +
 
 +
 
 +
The equipment on the site consists of the following:
 +
 
 +
 
 +
 
 +
 
 +
 
 +
On 12/13/2016, Northeast Regional Supervisor Tom Hill and I met with Justin Caldwell, co-owner of PAC Drilling, and Rusty Hornhill, well tender for PAC Drilling concerning the missing required urban safety equipment on 31 PAC Drilling wells in Hubbard and Liberty Townships.  Mr. Caldwell has been given a document listing the wells with the missing the urban safety equipment.  PAC Drilling is to submit a schedule for equipment installation for review and approval by the Division of Oil & Gas.
 +
|-
 +
| 0583375018
 +
| 2019-02-28
 +
| UrbanProduction Wells
 +
| No Violations
 +
| I conducted a compliance notice follow-up for compliance notice 1356512650.  At the time of this inspection, The identification and fencing still needs to be installed at the well.  The 210 BBL storage tank was missing the required urban safety equipment, spark arrestor and low pressure relief valve.  A charcoal filter has been installed on the 210 BBL tank.  The identification sign was missing the required information per 1501:9-9-05E(1)(a-e).  The production tank is over 3 foot above the top of the fence.  The lease access gate was a steel wire.
 +
 
 +
PAC needs to:
 +
1)  Post an identification sign to be in compliance with 1501:9-9-05E(1)(a-e) at the tank battery with:
 +
Well owners address and phone number
 +
Property street address or nearest address to the access road entrance.
 +
2)  Install urban safety equipment on the production tank as required by 1501:9-9-05E(4)(b-e):
 +
Functioning low-pressure relief valve.
 +
Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. 
 +
Functioning lightning arrestor.
 +
3)  Install a fence around the well as required by 1501:9-9-05E(2)
 +
4)  Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05E(4)(f).
 +
|-
 +
| 0617676889
 +
| 2011-09-27
 +
| Preliminary Restoration
 +
| No Violations
 +
| Preliminary Restoration meets all requirements.
 +
|-
 +
| 0947395401
 +
| 2017-04-24
 +
| UrbanProduction Wells
 +
| No Violations
 +
| I found the well in production on the day of my inspection.  The well is equipped with a plunger lift assembly.  The gate valve on the tubing is open.  The identification sign at the well is lying on the ground.  There is no fencing around the well and was not waived during the pre---up line is missing a plug.  The 210 bbl. storage tank is missing the required urban safety equipment.  The identification sign is missing the required information per 1501:9-9-05(E)(1)(a-
 +
 
 +
The equipment on the pad consists of the following:
 +
 
 +
 
 +
 
 +
 
 
|-
 
|-
 
| 1171353805
 
| 1171353805
 
| 2014-10-22
 
| 2014-10-22
|  
+
| UrbanProduction Wells
 +
| No Violations
 
| I was on location for a status check.  During my inspection, I found the well in production.  The well was equipped with a plunger lift assembly.  The tank batter consisted of a 210 barrel production tank, a 50 barrel brine tank and a separator.  There was a locked, chain link fence surrounding the tank battery.  A dike surrounded the production equipment.  Identification signs were posted at the well and tank battery.  A bull plug was installed on the load line.  The lease road was in stable condition.
 
| I was on location for a status check.  During my inspection, I found the well in production.  The well was equipped with a plunger lift assembly.  The tank batter consisted of a 210 barrel production tank, a 50 barrel brine tank and a separator.  There was a locked, chain link fence surrounding the tank battery.  A dike surrounded the production equipment.  Identification signs were posted at the well and tank battery.  A bull plug was installed on the load line.  The lease road was in stable condition.
|
 
|
 
|
 
 
|-
 
|-
 +
| 1356512650
 +
| 2017-10-11
 +
| UrbanProduction Wells
 +
| Violations Noted
 +
| I found the well in production on the day of my inspection.  The identification sign at the well is lying on the ground.  There is no fencing around the well and was not waived during the pre---up line is missing a plug.  The 210 bbl. storage tank is missing the required urban safety equipment.  The identification sign is missing the required information per 1501:9-9--
 +
 +
PAC needs to:
 +
1)  Post an identification sign to be in compliance with 1501:9-9--e) at the tank battery with:
 +
Well owners address and phone number
 +
Property street address or nearest address to the access road entrance.
 +
2)  Install urban safety equipment on the production tank as required by 1501:9-9--e):
 +
Activated charcoal filters.
 +
Functioning low-pressure relief valve.
 +
Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. 
 +
Functioning lightning arrestor.
 +
3)  Install a fence around the wellhead as required by 1501:9-9-
 +
-up line.
 +
5)  Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-
 +
|-
 +
| 1755279961
 +
| 2018-05-17
 +
| UrbanProduction Wells
 +
| No Violations
 +
| I conducted a compliance notice follow-up for compliance notice 1356512650.  The well was equipped with a plunger lift assembly and the annulus and flow line valves were open.  There was no signage or fencing installed at the well.  The diked tank battery has two storage tanks and a separator.  The pick-up line was secure with a plug and the handle has been removed from the valve.  The 210 BBL storage tank was missing the required urban safety equipment.  The identification sign was missing the required information per 1501:9-9--e).  A locked chain link fence surrounds the tank battery.  The production tank is over 3 foot above the top of the fence.  The access road was stable, with a steel wire as the gate.
 +
 +
PAC needs to:
 +
1)  Post an identification sign to be in compliance with 1501:9-9--e) at the tank battery with:
 +
Well owners address and phone number
 +
Property street address or nearest address to the access road entrance.
 +
2)  Install urban safety equipment on the production tank as required by 1501:9-9--e):
 +
Activated charcoal filters.
 +
Functioning low-pressure relief valve.
 +
Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. 
 +
Functioning lightning arrestor.
 +
3)  Install a fence around the well as required by 1501:9-9-
 +
4)  Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-
 +
|-
 +
|}
 +
==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Violation ID
 +
!scope="col" style="text-align: center"| Violation Date
 +
!scope="col" style="text-align: center"| Violation Code
 +
!scope="col" style="text-align: center"| Violation Comments
 
|-
 
|-
| -617676889
+
| 1356512650
| 2011-09-27
+
| US-OH-110310
|  
+
| 2017-12-26
| Preliminary Restoration meets all requirements.
 
 
|  
 
|  
 +
| ID (a-i)
 +
|-
 +
| 1356512650
 +
| US-OH-110311
 +
| 2017-12-26
 
|  
 
|  
 +
| FENCING (a-d)
 +
|-
 +
| 1356512650
 +
| US-OH-110312
 +
| 2017-12-26
 
|  
 
|  
 +
| TANKS (a-i)
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Ohio Department of Natural Resources RBDMS
+
  | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
  | publisher = [http://oilandgas.ohiodnr.gov/]
+
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2015-06-19
+
  | date = 2019-05-07
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection
+
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2015-06-20 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
== References ==
+
==References==
{{reflist}}
+
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Ohio Wells]]

Revision as of 18:47, 24 July 2019

Well Details

Well ID: 34-155-23980
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hubbard
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: SARISKY
License Status: Producing
License Date: 2009-06-04
Spud Date: 2008-11-18
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2008-11-24
Well Total Depth: 5276 ft
Configuration: Vertical
Latitude: 41.187225409
Longitude: -80.58969344

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-11-14 Proposed Formations:CLINTON/MEDINA, Issued Date:11/14/2008, Expired Date:11/14/2009 6:00:00 AM, Drilling unit acres:46.56, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-11-24
Completion Report Received 2009-03-06
Construction Permit Expires 2009-11-14
Record Last Modified 2015-09-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-06-04 4972 5050 39
2009-06-04 5132 5136 6

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 20 0 34500

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 PAC DRILLING LLC 23725 506 351
2010 PAC DRILLING LLC 20250 210 349
2011 PAC DRILLING LLC 8649 203 335
2012 PAC DRILLING LLC 4632 166 334
2013 PAC DRILLING LLC 3414 134 365
2014 PAC DRILLING LLC 3106 100 360
2015 PAC DRILLING LLC 3590 90 360
2016 PAC DRILLING LLC 2600 79 355
2017 PAC DRILLING LLC 2554 67 356
2018 PAC DRILLING LLC 2441 146 356

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 PAC DRILLING LLC Brine 50 351
2010 PAC DRILLING LLC Brine 70 349
2011 PAC DRILLING LLC Brine 40 335
2012 PAC DRILLING LLC Brine 40 334
2013 PAC DRILLING LLC Brine 57 365
2014 PAC DRILLING LLC Brine 57 360
2015 PAC DRILLING LLC Brine 37 360
2016 PAC DRILLING LLC Brine 0 355
2017 PAC DRILLING LLC Brine 0 356
2018 PAC DRILLING LLC Brine 0 356

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0317875937 2016-11-09 UrbanProduction Wells No Violations


PAC Drilling will: Install locks on the load lines or remove the valve handles Install the required safety equipment


-pressure relief valve


The equipment on the site consists of the following:



On 12/13/2016, Northeast Regional Supervisor Tom Hill and I met with Justin Caldwell, co-owner of PAC Drilling, and Rusty Hornhill, well tender for PAC Drilling concerning the missing required urban safety equipment on 31 PAC Drilling wells in Hubbard and Liberty Townships. Mr. Caldwell has been given a document listing the wells with the missing the urban safety equipment. PAC Drilling is to submit a schedule for equipment installation for review and approval by the Division of Oil & Gas.

0583375018 2019-02-28 UrbanProduction Wells No Violations I conducted a compliance notice follow-up for compliance notice 1356512650. At the time of this inspection, The identification and fencing still needs to be installed at the well. The 210 BBL storage tank was missing the required urban safety equipment, spark arrestor and low pressure relief valve. A charcoal filter has been installed on the 210 BBL tank. The identification sign was missing the required information per 1501:9-9-05E(1)(a-e). The production tank is over 3 foot above the top of the fence. The lease access gate was a steel wire.

PAC needs to: 1) Post an identification sign to be in compliance with 1501:9-9-05E(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install urban safety equipment on the production tank as required by 1501:9-9-05E(4)(b-e): Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor. 3) Install a fence around the well as required by 1501:9-9-05E(2) 4) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05E(4)(f).

0617676889 2011-09-27 Preliminary Restoration No Violations Preliminary Restoration meets all requirements.
0947395401 2017-04-24 UrbanProduction Wells No Violations I found the well in production on the day of my inspection. The well is equipped with a plunger lift assembly. The gate valve on the tubing is open. The identification sign at the well is lying on the ground. There is no fencing around the well and was not waived during the pre---up line is missing a plug. The 210 bbl. storage tank is missing the required urban safety equipment. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a-

The equipment on the pad consists of the following:



1171353805 2014-10-22 UrbanProduction Wells No Violations I was on location for a status check. During my inspection, I found the well in production. The well was equipped with a plunger lift assembly. The tank batter consisted of a 210 barrel production tank, a 50 barrel brine tank and a separator. There was a locked, chain link fence surrounding the tank battery. A dike surrounded the production equipment. Identification signs were posted at the well and tank battery. A bull plug was installed on the load line. The lease road was in stable condition.
1356512650 2017-10-11 UrbanProduction Wells Violations Noted I found the well in production on the day of my inspection. The identification sign at the well is lying on the ground. There is no fencing around the well and was not waived during the pre---up line is missing a plug. The 210 bbl. storage tank is missing the required urban safety equipment. The identification sign is missing the required information per 1501:9-9--

PAC needs to: 1) Post an identification sign to be in compliance with 1501:9-9--e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install urban safety equipment on the production tank as required by 1501:9-9--e): Activated charcoal filters. Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor. 3) Install a fence around the wellhead as required by 1501:9-9- -up line. 5) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-

1755279961 2018-05-17 UrbanProduction Wells No Violations I conducted a compliance notice follow-up for compliance notice 1356512650. The well was equipped with a plunger lift assembly and the annulus and flow line valves were open. There was no signage or fencing installed at the well. The diked tank battery has two storage tanks and a separator. The pick-up line was secure with a plug and the handle has been removed from the valve. The 210 BBL storage tank was missing the required urban safety equipment. The identification sign was missing the required information per 1501:9-9--e). A locked chain link fence surrounds the tank battery. The production tank is over 3 foot above the top of the fence. The access road was stable, with a steel wire as the gate.

PAC needs to: 1) Post an identification sign to be in compliance with 1501:9-9--e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install urban safety equipment on the production tank as required by 1501:9-9--e): Activated charcoal filters. Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor. 3) Install a fence around the well as required by 1501:9-9- 4) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1356512650 US-OH-110310 2017-12-26 ID (a-i)
1356512650 US-OH-110311 2017-12-26 FENCING (a-d)
1356512650 US-OH-110312 2017-12-26 TANKS (a-i)

For data sources see[9]

References