X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-053-60003"

m
m
Line 1: Line 1:
__TOC__
+
__TOC__
 
== Well Details ==
 
== Well Details ==
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-053-60003
 
| Well ID: 34-053-60003
| style="height=100%; align=center" rowspan="15" | {{#display_map: 38.92515091, -82.16882172 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 38.924873989, -82.16754841 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Gallia County, Ohio|Gallia]]
+
| Country: United States
 
|-
 
|-
| Municipality:  
+
| State: Ohio
 +
|-
 +
| County: [[Gallia_County,_Ohio|Gallia]]
 +
|-
 +
| Municipality: [[Addison_Township,_Gallia_County,_Ohio|Addison Township]]
 
|-
 
|-
 
| Operator Name: [[OHIO VALLEY ELECTRIC CORP]]
 
| Operator Name: [[OHIO VALLEY ELECTRIC CORP]]
Line 13: Line 17:
 
| Well Pad ID:  
 
| Well Pad ID:  
 
|-
 
|-
| Farm/Lease Name:  
+
| Farm/Lease Name: SHAVER OLIVER
 
|-
 
|-
| First Permit Date:  
+
| License Status: Final Restoration
 
|-
 
|-
| Last Permit Date:  
+
| License Date: 2015-02-13
 
|-
 
|-
 
| Spud Date: 1932-07-01
 
| Spud Date: 1932-07-01
 
|-
 
|-
| Unconventional: No
+
| Spud Drilling Contractor:  
 +
|-
 +
| Final Drill Date: 1932-07-25
 +
|-
 +
| Well Total Depth: 1720 ft
 
|-
 
|-
 
| Configuration: Vertical
 
| Configuration: Vertical
 
|-
 
|-
| Well Status: Final Restoration
+
| Latitude: 38.924873989
 
|-
 
|-
| Violations: 0
+
| Longitude: -82.16754841
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Well Status
 +
!scope="col" style="width: 15%;text-align: center"| Well Status Date
 +
!scope="col" style="text-align: center"| Comment
 
|-
 
|-
| Latitude: 38.92515091
+
| Original Spud
 +
| 1932-07-01
 +
| INSPECTED BY LINDA SLATER BEFORE APRIL 18, 2005. SHE ACCOMPANIED MICHALE ALTIER TO THIS WELL AS HE PUT UP AN ID. QUAD=PT. PLEASANT, GL=739.98
 
|-
 
|-
| Longitude: -82.16882172
+
| Completed
 +
| 1932-07-25
 +
| INSPECTED BY LINDA SLATER BEFORE APRIL 18, 2005. SHE ACCOMPANIED MICHALE ALTIER TO THIS WELL AS HE PUT UP AN ID. QUAD=PT. PLEASANT, GL=739.98
 
|-
 
|-
|}
+
| Reached Total Depth
== Inspection Data ==
+
| 1932-07-25
{| class="wikitable sortable" width="95%"
+
| INSPECTED BY LINDA SLATER BEFORE APRIL 18, 2005. SHE ACCOMPANIED MICHALE ALTIER TO THIS WELL AS HE PUT UP AN ID. QUAD=PT. PLEASANT, GL=739.98
!scope="col" | INSPECTION ID
+
|-
!scope="col" | DATE
+
| Change of Owner
!scope="col" | DESCRIPTION
+
| 2005-09-15
!scope="col" | COMMENT
+
| Operator changed from 9999, UNKNOWN OWNER to 1982, MGA ENERGY INC.  WELLS TRANSFERRED TO MGA PER LINDA SLATER.
!scope="col" | VIOLATION ID
+
|-
!scope="col" | VIOLATION CODE
+
| Change of Owner
!scope="col" | VIOLATION COMMENT
+
| 2008-04-22
 +
| Operator changed from 1982, MGA ENERGY INC to 8161, OHIO VALLEY ELECTRIC CORP
 
|-
 
|-
| -1070888011
+
| APP
| 2005-04-05
+
| 2008-05-05
|  
+
| Proposed Formations:BEREA, Issued Date:5/5/2008, Expired Date:5/5/2009 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
| Accompanied Michael Altier; witnessed placement of  ID.
 
|
 
|
 
| Informal Letter
 
 
|-
 
|-
 +
| Plugged/Abandoned
 +
| 2008-05-15
 +
| INSPECTED BY LINDA SLATER BEFORE APRIL 18, 2005. SHE ACCOMPANIED MICHALE ALTIER TO THIS WELL AS HE PUT UP AN ID. QUAD=PT. PLEASANT, GL=739.98
 
|-
 
|-
| 1206031036
+
| Construction Permit Expires
| 2008-03-03
+
| 2009-05-05
|  
+
| INSPECTED BY LINDA SLATER BEFORE APRIL 18, 2005. SHE ACCOMPANIED MICHALE ALTIER TO THIS WELL AS HE PUT UP AN ID. QUAD=PT. PLEASANT, GL=739.98
| This well is to be plugged by OVEC as part of their FGD Landfill project. A 14 steel conductor has a 6 Od casing in it that is sealed at the surface with cement. The 6 casing has a 2 tubing in it. This 2 tubing has cement around it at the surface also. There are no hangers so the tubing must be on a packer of some sort.
 
|
 
|
 
|
 
 
|-
 
|-
 +
| Record Last Modified
 +
| 2017-02-15
 +
| INSPECTED BY LINDA SLATER BEFORE APRIL 18, 2005. SHE ACCOMPANIED MICHALE ALTIER TO THIS WELL AS HE PUT UP AN ID. QUAD=PT. PLEASANT, GL=739.98
 
|-
 
|-
| 1212585392
+
|}
| 2008-05-09
+
For data sources see<ref>{{cite web
|  
+
| title = Risk Based Data Management System - Well and WellHistry Tables
| Spot bottom plug by running 1 inside 2 tubing. Ran 1 to 1717.95' . Pulled 4 joints 1 and then circulated to clean out for wire line.
+
|publisher = [[Ohio Department of Natural Resources]]
|  
+
| date =  2019-05-07
|  
+
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
|  
+
| accessdate = 2019-05-21 }}</ref>
 +
<!--== Perforation Treatments ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Perforation Date
 +
!scope="col" style="text-align: center"| Interval Top (ft)
 +
!scope="col" style="text-align: center"| Interval Base (ft)
 +
!scope="col" style="text-align: center"| Number of Shots
 
|-
 
|-
 +
|}-->
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Job Start Date
 +
!scope="col" style="text-align: center"| Job End Date
 +
!scope="col" style="text-align: center"| True Vertical Depth (ft)
 +
!scope="col" style="text-align: center"| Total Water Volume (gal)
 +
!scope="col" style="text-align: center"| Total Non-Water Volume (gal)
 
|-
 
|-
| -1638793073
+
|}-->
| 2015-02-13
+
<!--==== Fluid Composition Data ====
|  
+
{| class="wikitable sortable" style="width: 100%"
| Final Restoration complete. Plugged well is now located in the Kyger Creek FGD Landfill site. Please see previous RBDMS reports for further clarification.
+
!scope="col" style="text-align: center"| Job Number
|  
+
!scope="col" style="text-align: center"| Trade Name
|  
+
!scope="col" style="text-align: center"| Supplier
|  
+
!scope="col" style="text-align: center"| Purpose
 +
!scope="col" style="text-align: center"| Ingredient Name
 +
!scope="col" style="white-space: nowrap;text-align: center"| CAS Number
 +
!scope="col" style="text-align: center"| Additive Percentage by Mass
 +
!scope="col" style="text-align: center"| Job Percentage by Mass
 +
!scope="col" style="text-align: center"| Mass Used (lb)
 
|-
 
|-
 +
|}-->
 +
== Stimulations Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Stimulation Date
 +
!scope="col" style="text-align: center"| Chemical Agent
 +
!scope="col" style="text-align: center"| Chemical Agent Concentration (%)
 +
!scope="col" style="text-align: center"| Fracking Fluid Volume
 +
!scope="col" style="text-align: center"| Mass of Proppant Used (lb)
 +
!scope="col" style="text-align: center"| Fracking Company
 +
!scope="col" style="text-align: center"| Comments
 
|-
 
|-
| -1856271519
 
| 2005-02-07
 
|
 
| No ID; still producing; belongs to MJA (Michael Altier).  Coords need adjusting - off about 300'.
 
 
|  
 
|  
 +
| Not Treated
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 20 Qts
 +
| style="text-align: right;" | 0
 
|  
 
|  
 
|  
 
|  
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - tblStimulation Table
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
<!--== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Gas Quantity (mcf)
 +
!scope="col" style="text-align: center"| Oil Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 
|-
 
|-
| -2013609551
+
|}-->
| 2005-02-07
+
<!--== Waste Data ==
|  
+
{| class="wikitable sortable"
| No ID; still producing; belongs to MJA (Michael Altier).  Coords need adjusting - off about 300'.
+
!scope="col" style="text-align: center"| Period
|  
+
!scope="col" style="text-align: center"| Operator Name
|  
+
!scope="col" style="text-align: center"| Waste Type
|  
+
!scope="col" style="text-align: center"| Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 
|-
 
|-
 +
|}-->
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Inspection Date
 +
!scope="col" style="text-align: center"| Inspection Type
 +
!scope="col" style="text-align: center"| Inspection Result
 +
!scope="col" style="text-align: center"| Inspection Comments
 
|-
 
|-
| 451178481
+
| 0451178481
 
| 2008-05-12
 
| 2008-05-12
|  
+
| Plug / Plug Back
| Rig has been vandalized. A fire extinguisher from the rig was set off in the cab of the rig. Some wrenches are missing from the rig. Debris was placed down the well. Obstruction hit at 686' wire line cannot get past it. Ran 1 jars could get to 700' then stopped. Ran 1 tubing back down to 1585' 1 pushed the obstruction down hole. Pulled 1 back out. Wire line shot at 1545' (7shots). 2 free set 300' plug through 2 then pulled 400' of 2 tubing and circulated 5 3/16 out. Pulled 1545' of  2 out.
+
| No Violations
|
+
| Rig has been vandalized. A fire extinguisher from the rig was set off in the cab of the rig. Some wrenches are missing from the rig. Debris was placed down the well. Obstruction hit at 686 wire line cannot get past it. Ran 1 jars could get to 700 then stopped. Ran 1 tubing back down to 1585 1 pushed the obstruction down hole. Pulled 1 back out. Wire line shot at 1545 (7shots). 2 free set 300 plug through 2 then pulled 400 of 2 tubing and circulated 5 3/16 out. Pulled 1545 of  2 out.
|
 
|
 
|-
 
 
|-
 
|-
| -534904644
+
| 0534904644
 
| 2008-05-13
 
| 2008-05-13
|  
+
| Plug / Plug Back
| Tag top of cement plug at 1185' Rig hands refused to check for fluid level. Timco ran casing cutter could only get to 290'. Tried to use collar buster and got to 805' Shot at 805' Casing jumped but rig could not pull casing. 2nd shot at 783' pulled 15,000lbs over string weight before shooting. 783'of 6 casing was pulled out.
+
| No Violations
|
+
| Tag top of cement plug at 1185 Rig hands refused to check for fluid level. Timco ran casing cutter could only get to 290. Tried to use collar buster and got to 805 Shot at 805 Casing jumped but rig could not pull casing. 2nd shot at 783 pulled 15,000lbs over string weight before shooting. 783of 6 casing was pulled out.
|
 
|
 
|-
 
 
|-
 
|-
| -588314355
+
| 0588314355
 
| 2008-05-14
 
| 2008-05-14
|  
+
| Plug / Plug Back
| Ran 671' of 2 tubing. Cement to surface. Did it in two lifts of 322' each. Cement did not circulate to surface. Cement truck ran out of cement. Will have to tag latter and order more cement.
+
| No Violations
|
+
| Ran 671 of 2 tubing. Cement to surface. Did it in two lifts of 322 each. Cement did not circulate to surface. Cement truck ran out of cement. Will have to tag latter and order more cement.
|
 
|
 
 
|-
 
|-
|-
+
| 0649767427
| 649767427
 
 
| 2008-05-15
 
| 2008-05-15
|  
+
| Plug / Plug Back
| Tag top of cement plug at 150' ran 2 tubing down to 150' and cemented to surface. Cement stayed at surface.
+
| No Violations
|
+
| Tag top of cement plug at 150 ran 2 tubing down to 150 and cemented to surface. Cement stayed at surface.
|
 
|
 
|-
 
 
|-
 
|-
| -801818636
+
| 0801818636
 
| 2005-10-05
 
| 2005-10-05
|  
+
| Production Wells
 +
| No Violations
 
| Need to correct coordinates.
 
| Need to correct coordinates.
|  
+
|-
|  
+
| 1070888011
|  
+
| 2005-04-05
 +
| Production Wells
 +
| No Violations
 +
| Accompanied Michael Altier; witnessed placement of  ID.
 +
|-
 +
| 1206031036
 +
| 2008-03-03
 +
| Production Wells
 +
| No Violations
 +
| This well is to be plugged by OVEC as part of their FGD Landfill project. A 14 steel conductor has a 6 Od casing in it that is sealed at the surface with cement. The 6 casing has a 2 tubing in it. This 2 tubing has cement around it at the surface also. There are no hangers so the tubing must be on a packer of some sort.
 +
|-
 +
| 1212585392
 +
| 2008-05-09
 +
| Plug / Plug Back
 +
| No Violations
 +
| Spot bottom plug by running 1 inside 2 tubing. Ran 1 to 1717.95 . Pulled 4 joints 1 and then circulated to clean out for wire line.
 +
|-
 +
| 1638793073
 +
| 2015-02-13
 +
| Final Restoration
 +
| No Violations
 +
| Final Restoration complete. Plugged well is now located in the Kyger Creek FGD Landfill site. Please see previous RBDMS reports for further clarification.
 +
|-
 +
| 1856271519
 +
| 2005-02-07
 +
| Production Wells
 +
| No Violations
 +
| No ID; still producing; belongs to MJA (Michael Altier).  Coords need adjusting - off about 300.
 +
|-
 +
| 2013609551
 +
| 2005-02-07
 +
| Production Wells
 +
| No Violations
 +
| No ID; still producing; belongs to MJA (Michael Altier).  Coords need adjusting - off about 300.
 
|-
 
|-
 
|}
 
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Violation ID
 +
!scope="col" style="text-align: center"| Violation Date
 +
!scope="col" style="text-align: center"| Violation Code
 +
!scope="col" style="text-align: center"| Violation Comments
 +
|-
 +
|}-->
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Ohio Department of Natural Resources RBDMS
+
  | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
  | publisher = [http://oilandgas.ohiodnr.gov/]
+
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2015-06-19
+
  | date = 2019-05-07
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection
+
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2015-06-20 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
== References ==
+
==References==
{{reflist}}
+
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Ohio Wells]]

Revision as of 04:47, 25 July 2019

Well Details

Well ID: 34-053-60003
Loading map...
Country: United States
State: Ohio
County: Gallia
Municipality: Addison Township
Operator Name: OHIO VALLEY ELECTRIC CORP
Well Pad ID:
Farm/Lease Name: SHAVER OLIVER
License Status: Final Restoration
License Date: 2015-02-13
Spud Date: 1932-07-01
Spud Drilling Contractor:
Final Drill Date: 1932-07-25
Well Total Depth: 1720 ft
Configuration: Vertical
Latitude: 38.924873989
Longitude: -82.16754841

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1932-07-01 INSPECTED BY LINDA SLATER BEFORE APRIL 18, 2005. SHE ACCOMPANIED MICHALE ALTIER TO THIS WELL AS HE PUT UP AN ID. QUAD=PT. PLEASANT, GL=739.98
Completed 1932-07-25 INSPECTED BY LINDA SLATER BEFORE APRIL 18, 2005. SHE ACCOMPANIED MICHALE ALTIER TO THIS WELL AS HE PUT UP AN ID. QUAD=PT. PLEASANT, GL=739.98
Reached Total Depth 1932-07-25 INSPECTED BY LINDA SLATER BEFORE APRIL 18, 2005. SHE ACCOMPANIED MICHALE ALTIER TO THIS WELL AS HE PUT UP AN ID. QUAD=PT. PLEASANT, GL=739.98
Change of Owner 2005-09-15 Operator changed from 9999, UNKNOWN OWNER to 1982, MGA ENERGY INC. WELLS TRANSFERRED TO MGA PER LINDA SLATER.
Change of Owner 2008-04-22 Operator changed from 1982, MGA ENERGY INC to 8161, OHIO VALLEY ELECTRIC CORP
APP 2008-05-05 Proposed Formations:BEREA, Issued Date:5/5/2008, Expired Date:5/5/2009 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2008-05-15 INSPECTED BY LINDA SLATER BEFORE APRIL 18, 2005. SHE ACCOMPANIED MICHALE ALTIER TO THIS WELL AS HE PUT UP AN ID. QUAD=PT. PLEASANT, GL=739.98
Construction Permit Expires 2009-05-05 INSPECTED BY LINDA SLATER BEFORE APRIL 18, 2005. SHE ACCOMPANIED MICHALE ALTIER TO THIS WELL AS HE PUT UP AN ID. QUAD=PT. PLEASANT, GL=739.98
Record Last Modified 2017-02-15 INSPECTED BY LINDA SLATER BEFORE APRIL 18, 2005. SHE ACCOMPANIED MICHALE ALTIER TO THIS WELL AS HE PUT UP AN ID. QUAD=PT. PLEASANT, GL=739.98

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 20 Qts 0

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0451178481 2008-05-12 Plug / Plug Back No Violations Rig has been vandalized. A fire extinguisher from the rig was set off in the cab of the rig. Some wrenches are missing from the rig. Debris was placed down the well. Obstruction hit at 686 wire line cannot get past it. Ran 1 jars could get to 700 then stopped. Ran 1 tubing back down to 1585 1 pushed the obstruction down hole. Pulled 1 back out. Wire line shot at 1545 (7shots). 2 free set 300 plug through 2 then pulled 400 of 2 tubing and circulated 5 3/16 out. Pulled 1545 of 2 out.
0534904644 2008-05-13 Plug / Plug Back No Violations Tag top of cement plug at 1185 Rig hands refused to check for fluid level. Timco ran casing cutter could only get to 290. Tried to use collar buster and got to 805 Shot at 805 Casing jumped but rig could not pull casing. 2nd shot at 783 pulled 15,000lbs over string weight before shooting. 783of 6 casing was pulled out.
0588314355 2008-05-14 Plug / Plug Back No Violations Ran 671 of 2 tubing. Cement to surface. Did it in two lifts of 322 each. Cement did not circulate to surface. Cement truck ran out of cement. Will have to tag latter and order more cement.
0649767427 2008-05-15 Plug / Plug Back No Violations Tag top of cement plug at 150 ran 2 tubing down to 150 and cemented to surface. Cement stayed at surface.
0801818636 2005-10-05 Production Wells No Violations Need to correct coordinates.
1070888011 2005-04-05 Production Wells No Violations Accompanied Michael Altier; witnessed placement of ID.
1206031036 2008-03-03 Production Wells No Violations This well is to be plugged by OVEC as part of their FGD Landfill project. A 14 steel conductor has a 6 Od casing in it that is sealed at the surface with cement. The 6 casing has a 2 tubing in it. This 2 tubing has cement around it at the surface also. There are no hangers so the tubing must be on a packer of some sort.
1212585392 2008-05-09 Plug / Plug Back No Violations Spot bottom plug by running 1 inside 2 tubing. Ran 1 to 1717.95 . Pulled 4 joints 1 and then circulated to clean out for wire line.
1638793073 2015-02-13 Final Restoration No Violations Final Restoration complete. Plugged well is now located in the Kyger Creek FGD Landfill site. Please see previous RBDMS reports for further clarification.
1856271519 2005-02-07 Production Wells No Violations No ID; still producing; belongs to MJA (Michael Altier). Coords need adjusting - off about 300.
2013609551 2005-02-07 Production Wells No Violations No ID; still producing; belongs to MJA (Michael Altier). Coords need adjusting - off about 300.