Line 11: Line 11:
 
| County: [[Cuyahoga_County,_Ohio|Cuyahoga]]
 
| County: [[Cuyahoga_County,_Ohio|Cuyahoga]]
 
|-
 
|-
| Municipality:  
+
| Municipality: Orange Township
 
|-
 
|-
 
| Operator Name: [[PEP DRILLING LLC]]
 
| Operator Name: [[PEP DRILLING LLC]]
Line 21: Line 21:
 
| License Status: Producing
 
| License Status: Producing
 
|-
 
|-
| License Date: 2008-05-30
+
| License Date: 2007-08-27
 
|-
 
|-
 
| Spud Date: 2007-09-06
 
| Spud Date: 2007-09-06

Revision as of 14:19, 25 July 2019

Well Details

Well ID: 34-035-21995
Loading map...
Country: United States
State: Ohio
County: Cuyahoga
Municipality: Orange Township
Operator Name: PEP DRILLING LLC
Well Pad ID:
Farm/Lease Name: GRAEFF
License Status: Producing
License Date: 2007-08-27
Spud Date: 2007-09-06
Spud Drilling Contractor: PEP DRLG
Final Drill Date: 2007-09-12
Well Total Depth: 3860 ft
Configuration: Vertical
Latitude: 41.447420514
Longitude: -81.46851659

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-08-27 Proposed Formations:ORISKANY THRU CLINTON, Issued Date:8/27/2007, Expired Date:8/26/2008 6:00:00 AM, Drilling unit acres:28.14, Proposed Well Type:OG, Proposed Well Class:
Reached Total Depth 2007-09-12
Completion Report Received 2008-02-21
Construction Permit Expires 2008-08-26
Change of Owner 2016-03-04 Operator changed from 1198, PIPES PURSIE E to 9640, PEP DRILLING LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-05-30 3666 3718 111

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2400 Bbl 25000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 PIPES PURSIE E 5609 1186 319
2009 PIPES PURSIE E 454 606 365
2010 PIPES PURSIE E 3266 421 365
2011 PIPES PURSIE E 2424 346 365
2012 PIPES PURSIE E 2170 215 366
2013 PIPES PURSIE E 2039 325 365
2014 PIPES PURSIE E 1633 94 365
2016 PEP DRILLING LLC 1395 244 365
2017 PEP DRILLING LLC 848 0 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 PIPES PURSIE E Brine 1135 319
2009 PIPES PURSIE E Brine 4405 365
2010 PIPES PURSIE E Brine 353 365
2011 PIPES PURSIE E Brine 166 365
2012 PIPES PURSIE E Brine 160 366
2013 PIPES PURSIE E Brine 160 365
2014 PIPES PURSIE E Brine 65 365
2016 PEP DRILLING LLC Brine 0 365
2017 PEP DRILLING LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0156246986 2007-11-13 Drill / Deepen / Reopen No Violations area around well being graded
0287538789 2007-10-10 Drill / Deepen / Reopen No Violations
0594593159 2017-10-04 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: The wellhead and tank battery enclosures were locked and secure. Tank lids were closed and sealed. Load lines were closed, plugged, and secured with locks. The secondary containment was intact and dry with no signs of leaks or spills. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas surrounding the wellhead and battery which are comprised of meadow grasses and lightly wooded areas, and found no evidence of problems or impact to the surrounding greenscape attributable to the on-going production activity.
0724581369 2017-05-30 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the tiem of this inspection, I observed the following: The wellhead and tank battery enclosures were locked and secure. Tank lids were closed and sealed. Load lines were closed, plugged, and secured with locks. The secondary containment was intact and dry with no signs of leaks or spills. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas surrounding the wellhead and battery which are comprised of meadow grasses and lightly wooded areas, and found no evidence of problems or impact to the surrounding greenscape attributable to the on-going production activity.
1403103293 2014-06-18 UrbanProduction Wells No Violations I inspected this producing unit as part of regular site check and inspection activity. The well was completed on 2/21/2008. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger lift system. The wellhead is located in a closed and locked board-on-board enclosure. There are no signs of leakage or problems at the wellhead. The aboveground storage tank battery is located west and adjacent to the wellhead. The battery is comprised of 2 steel 100-barrel production tanks, and a horizontal separator. The battery is located in a separate board-on-board enclosure which is gated and locked. The load-outs are bull-plugged and locked. There is process safety equipment in use (carbon filter, low-pressure relief valve, and spark arrestor). The secondary containment at the battery appears well maintained. I did not observe any signs or evidence of leakage, spills, or problems. There is ID signage at the battery and wellhead which are legible and in good condition. The area of the well is generally level with a slight topographic drop to the west. Surface draining appears to be controlled by local infiltration. I did not observe any signs of gully formation or washouts. Access to the unit is afforded by a gravel-paved access road which is partially shared with the house at 29750 Havard Rd. The short access road is currently in good condition and free of washout or erosional deficits. Beyond the area cleared for the wellhead and tank battery, the areas surrounding the unit are heavily wooded with one single-family residential home bordering to the south, and no other residential strucutres within eyesight.
1777610717 2008-05-07 Drill / Deepen / Reopen No Violations checked aera wet
1846604316 2015-12-11 UrbanProduction Wells Violations Noted I inspected this producing well as part of routine inspection activity. The well and associated tank battery are located in the back of a single-family residence. At the time of this inspection, the enclosure gates at the wellhead and battery were locked and secure. Fittings and connections at the wellhead were secure and free from signs of leakage or problems. Areas around the wellhead and battery were comprised of grassy vegetation and wooded areas. I inspected the surrounding areas and did not observe any evidence of problems or impact. I observed the following maintenance deficiency: A portion of the battery enclosure fence is broken down and requires repair/replacement. I also observed the following safety deficiency: The production tank lids were old style hatch lids which do not seal and are not compliant with OAC 1501:9-9-05(E)(4)(d). Hatch lids must be replaced with lids that have functioning seals and must be closed and secure . These safety deficiencies must be addressed by 01/16/2016. Please contact Inspector Stephen Tompkins at 330-907-4647 regarding this inspection.
1923980459 2009-11-12 Preliminary Restoration No Violations no violation.
2136095567 2016-10-14 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previously-issued Compliance Notice. At the time of the previous inspection, I had noted that the tank lids were not capable of sealing as required by OAC 1501:9-9-05(E)(4)(d). At the time of this inspection, the lids had been replaced and were in compliance. I inspected the rest of the production elements and observed the following: fittings and connections at the wellhead and battery were secure and free from leakage or problems. The secondary containment was intact and the interior was dry. The enclosure gates were locked and secure. The shared access road was in good condition.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1846604316 US-OH-118453 2017-07-12 TANKS (a-i)

For data sources see[9]