If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 21: | Line 21: | ||
| License Status: Producing | | License Status: Producing | ||
|- | |- | ||
− | | License Date: 2010- | + | | License Date: 2010-09-21 |
|- | |- | ||
| Spud Date: 2010-10-08 | | Spud Date: 2010-10-08 |
Well ID: 34-151-25696 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.844294383,"lon":-81.10292088,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Stark | |
Municipality: Washington Township | |
Operator Name: C & T ENERGY OF EAST CANTON IN | |
Well Pad ID: | |
Farm/Lease Name: STOUDT UNIT | |
License Status: Producing | |
License Date: 2010-09-21 | |
Spud Date: 2010-10-08 | |
Spud Drilling Contractor: ADVENT DRLG | |
Final Drill Date: 2010-10-12 | |
Well Total Depth: 5541 ft | |
Configuration: Vertical | |
Latitude: 40.844294383 | |
Longitude: -81.10292088 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2010-09-21 | Proposed Formations:CLINTON, Issued Date:9/21/2010, Expired Date:9/20/2012 12:00:00 PM, Drilling unit acres:40.76, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2010-10-12 | |
Construction Permit Expires | 2012-09-20 | |
Completion Report Received | 2013-09-23 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2013-09-24 | 5318 | 5426 | 53 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 178000 Gal | 76000 | Superior Well Services |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | C & T ENERGY OF EAST CANTON IN | 0 | 129 | 30 |
2011 | C & T ENERGY OF EAST CANTON IN | 20405 | 2470 | 0 |
2012 | C & T ENERGY OF EAST CANTON IN | 10697 | 1151 | 366 |
2013 | C & T ENERGY OF EAST CANTON IN | 8817 | 935 | 365 |
2014 | C & T ENERGY OF EAST CANTON IN | 6786 | 615 | 365 |
2015 | C & T ENERGY OF EAST CANTON IN | 5310 | 611 | 365 |
2016 | C & T ENERGY OF EAST CANTON IN | 4284 | 627 | 365 |
2017 | C & T ENERGY OF EAST CANTON IN | 4243 | 496 | 365 |
2018 | C & T ENERGY OF EAST CANTON IN | 2353 | 372 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | C & T ENERGY OF EAST CANTON IN | Brine | 1050 | 30 |
2011 | C & T ENERGY OF EAST CANTON IN | Brine | 1450 | |
2012 | C & T ENERGY OF EAST CANTON IN | Brine | 385 | 366 |
2013 | C & T ENERGY OF EAST CANTON IN | Brine | 350 | 365 |
2014 | C & T ENERGY OF EAST CANTON IN | Brine | 210 | 365 |
2015 | C & T ENERGY OF EAST CANTON IN | Brine | 140 | 365 |
2016 | C & T ENERGY OF EAST CANTON IN | Brine | 140 | 365 |
2017 | C & T ENERGY OF EAST CANTON IN | Brine | 70 | 365 |
2018 | C & T ENERGY OF EAST CANTON IN | Brine | 150 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0050014095 | 2011-11-01 | Preliminary Restoration | No Violations | The well is in production, the site is reclaimed, and identification signs are posted. The Preliminary Restoration is PASSED. |
0918000426 | 2011-02-11 | Preliminary Restoration | No Violations | The well is in production. There is evidence within the tank battery dike that a the stock tank overflowed. The release area is covered with straw and snow covered. |
1160153966 | 2010-12-01 | Preliminary Restoration | No Violations | The site is reclaimed and the well is in production. There was no vegetation observed, so I did not pass the Preliminary Restoration at this time. |
1286499642 | 2010-10-07 | Drill / Deepen / Reopen | No Violations | The drilling location is cut and the access is stoned. |
1287006352 | 2010-10-13 | Drill / Deepen / Reopen | No Violations | Cemented 4-1/2 dia casing. Good circulation was maintained throughout the entire cement job. Drilling pits and liners are intact. |
1287411832 | 2010-10-15 | Drill / Deepen / Reopen | No Violations | Advent Drilling is moving off of the location today. |
1656575198 | 2010-10-09 | Drill / Deepen / Reopen | No Violations | Cemented surface casing. Drilling pits and liners are intact. |
1688374840 | 2010-10-08 | Drill / Deepen / Reopen | No Violations | Advent Drilling is moving onto the location and will spud today. |