X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-151-25710"

m
m
Line 21: Line 21:
 
| License Status: Producing
 
| License Status: Producing
 
|-
 
|-
| License Date: 2011-05-18
+
| License Date: 2010-11-17
 
|-
 
|-
 
| Spud Date: 2011-01-07
 
| Spud Date: 2011-01-07

Revision as of 06:23, 26 July 2019

Well Details

Well ID: 34-151-25710
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Lake Township
Operator Name: C & T ENERGY OF EAST CANTON IN
Well Pad ID:
Farm/Lease Name: BRADFORD UNIT
License Status: Producing
License Date: 2010-11-17
Spud Date: 2011-01-07
Spud Drilling Contractor: ADVENT DRLG
Final Drill Date: 2011-01-17
Well Total Depth: 4538 ft
Configuration: Vertical
Latitude: 40.977761926
Longitude: -81.39542153

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-11-17 Proposed Formations:CLINTON, Issued Date:11/17/2010, Expired Date:11/16/2012 12:00:00 PM, Drilling unit acres:40.7, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2011-01-17
Completion Report Received 2011-02-15
Construction Permit Expires 2011-11-17
Correction to Well 2013-04-05 UNIT SIZE INCREASED TO 56.47 ACRES.
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-05-19 4343 4395 20

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2011-01-28 H2O 8 88500 Gal 68500 Superior Well Services

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 C & T ENERGY OF EAST CANTON IN 11130 10117 0
2012 C & T ENERGY OF EAST CANTON IN 13870 5851 366
2013 C & T ENERGY OF EAST CANTON IN 9983 4013 365
2014 C & T ENERGY OF EAST CANTON IN 7817 2797 365
2015 C & T ENERGY OF EAST CANTON IN 7329 1930 365
2016 C & T ENERGY OF EAST CANTON IN 6713 1732 365
2017 C & T ENERGY OF EAST CANTON IN 7114 1431 365
2018 C & T ENERGY OF EAST CANTON IN 8781 1425 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 C & T ENERGY OF EAST CANTON IN Brine 1063
2012 C & T ENERGY OF EAST CANTON IN Brine 369 366
2013 C & T ENERGY OF EAST CANTON IN Brine 297 365
2014 C & T ENERGY OF EAST CANTON IN Brine 220 365
2015 C & T ENERGY OF EAST CANTON IN Brine 191 365
2016 C & T ENERGY OF EAST CANTON IN Brine 110 365
2017 C & T ENERGY OF EAST CANTON IN Brine 225 365
2018 C & T ENERGY OF EAST CANTON IN Brine 150 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0547360048 2011-01-28 Urban Drill / Deepen / Reopen No Violations On 1/27, Hotwell logged and perforated the well with 20 shots from 4343 to 4395. On 1/28, Superior Well Services was on site to frac the well. This slick-water job started with 1000 gallons of 15% iron acid. Superior pumped a total of 88,500 gallons of slurry with 65,500 lbs of 20/40 sand. The formation broke at 1153 psi with an average treating pressure of 2004 psi at an average rate of 39.8 bpm. The initial shut in pressure was 1406 psi and the five minute shut in pressure was 1367 psi. Superior rigged down and the wellhead was set up to flow back into the open pit.
0760252295 2012-01-04 Preliminary Restoration No Violations The site has been reclaimed and vegetation is established. Identification signs have been posted at the wellhead and at the tank battery. Locks have been placed on the wellhead gate and the tank battery gate. The natural gas meter run at Mogadore Road has been fenced off. The Preliminary Restoration is PASSED.
1173455249 2011-02-24 Preliminary Restoration No Violations The drilling pits are closed and the well is in production.
1294844875 2011-01-06 Urban Drill / Deepen / Reopen No Violations Advent Drilling is on site and will spud later tonight or early tomorrow morning. The pits are fenced lined and in good condition. The well will be drilled entirely on fluid. The required identification is posted at the lease entrance.
1295476726 2011-01-10 Urban Drill / Deepen / Reopen No Violations Advent Drilling is drilling surface hole with fresh water mud. Should be ready to set and cement surface casing later today. The drilling pits are fenced, lined and in good condition.
1295488280 2011-01-11 Urban Drill / Deepen / Reopen No Violations After waiting on surface casing cement, Advent broke off the landing joint and rigged up the blowout preventor. Successfully completed the pressure test of the BOP. Advent will start drilling the 7-7/8 hole later this morning. The well will be drilled on fluid.
1295876886 2011-01-18 Urban Drill / Deepen / Reopen No Violations Advent Drilling finished the well and ran 4-1/2 casing on 1/17. The derrick was down and the rig was secured. They will be moving off tomorrow. The drilling pits are fenced, lined and in good condition with sufficient freeboard.
1311300537 2011-07-20 Preliminary Restoration No Violations The site has been reclaimed and vegetation is established. The Preliminary Restoration is PASSED. I.D. signs need to be posted at the wellhead and at the tank battery. Locks need to be placed on the wellhead gate and the tank battery gate. The natural gas meter run at Mogadore Rd. needs to be fenced off. I will call Rob Frock.
1354286393 2011-01-14 Urban Drill / Deepen / Reopen No Violations Advent is drilling ahead and should finish within 48 hours. The drilling pits are fenced, lined and in good condition.
1391200696 2014-01-31 Production Wells No Violations I was on site to perform an inspection on this well in regards to complaint #4589. Complainant states that there is oil in her gas lines and she is afraid that it will get in her water supply. Dominion is on location purging the gas lines and the Health Dept. recommended she call the Division of Oil & Gas because there is a gas well within the vicinity that was drilled a year ago. I talked with Andy Smith, (330-831-1553) C & T Energy Pumper, who stated that the sales line for this well may have sent oil into the Dominion gas line. He has shut down the four wells (other wells #25710, 25770 and 25817 ) that sell into this sales line. I performed an inspection of this well and found a fully fenced in pump jack in good mechanical condition and contained all the proper identification, valves and annular gauges which showed no pressures on any casings but the production casing. The lease road was stable, plowed and the tank battery was fully fenced, contained the proper identification and had a SPPC dike. The tank battery is fully fenced and is shared with well #25828 and 25770 and contained three 100 bbl production tank, two 50 brine tanks and a poly brine tank. It also contained three vertical separators. All the equipment has bull plugs and locks. There are no violations at this time.
1704519687 2011-01-10 Drill / Deepen / Reopen No Violations I performed a rig inspection on Advent rig #1. The rig was drilling the surface hole and the drilling depth was 681 drilling on fluid. The ID sign was posted and a fence was around the drilling pits. This inspection satisfies 1501:9-9-03. There were no violations at this time.
1735506950 2011-01-05 Urban Drill / Deepen / Reopen No Violations Advent Drilling has started moving equipment on site and have dug the pits which are fenced. The permit information is posted at the lease entrance.

For data sources see[9]

References