If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 21: | Line 21: | ||
| License Status: Producing | | License Status: Producing | ||
|- | |- | ||
− | | License Date: 2013- | + | | License Date: 2013-04-15 |
|- | |- | ||
| Spud Date: 2013-05-28 | | Spud Date: 2013-05-28 |
Well ID: 34-089-26128 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.100795564,"lon":-82.64619579,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Licking | |
Municipality: St. albans Township | |
Operator Name: KNOX ENERGY INC. | |
Well Pad ID: | |
Farm/Lease Name: DONAHEY R | |
License Status: Producing | |
License Date: 2013-04-15 | |
Spud Date: 2013-05-28 | |
Spud Drilling Contractor: KILBARGER DRLG | |
Final Drill Date: 2013-06-01 | |
Well Total Depth: 2041 ft | |
Configuration: Vertical | |
Latitude: 40.100795564 | |
Longitude: -82.64619579 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2013-04-15 | Proposed Formations:BEREA THRU CLINTON, Issued Date:4/15/2013, Expired Date:4/15/2015 12:00:00 PM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2013-06-01 | |
Completion Report Received | 2013-08-30 | |
Construction Permit Expires | 2015-04-15 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2013-09-06 | 1935 | 1942 | 15 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2013-06-14 | H2O | 0 | 40000 Gal | 20000 | Producers Service Corporation | Producers Service Corp. on location to frac the Donahey #4 for Knox Energy. Bill Mitton was on location for Knox Energy. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | KNOX ENERGY INC. | 0 | 210 | 108 |
2014 | KNOX ENERGY INC. | 0 | 532 | 365 |
2015 | KNOX ENERGY INC. | 0 | 446 | 365 |
2016 | KNOX ENERGY INC. | 0 | 372 | 365 |
2017 | KNOX ENERGY INC. | 0 | 281 | 365 |
2018 | KNOX ENERGY INC. | 0 | 263 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | KNOX ENERGY INC. | Brine | 366 | 108 |
2014 | KNOX ENERGY INC. | Brine | 17 | 365 |
2015 | KNOX ENERGY INC. | Brine | 5 | 365 |
2016 | KNOX ENERGY INC. | Brine | 5 | 365 |
2017 | KNOX ENERGY INC. | Brine | 0 | 365 |
2018 | KNOX ENERGY INC. | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0078471032 | 2013-11-25 | Preliminary Restoration | No Violations | This inspection was conducted as a preliminary restoration status check. The well was equipped with a pumping unit and motor. A GPS reading was taken at the wellhead. The well is located in an agricultural field. The area around the well has been restored. The tank battery consists of (1) 210 barrel tank and (2) 100 barrel tanks inside an earthen dike. A GPS reading was taken at the tank battery location. This well shares the tank battery with p# 3646. Identification posted at wellhead and tank battery. Inspection meets ORC 1509.072 requirements. Weather: 22 degrees F, Clear |
0573694346 | 2013-06-07 | Drill / Deepen / Reopen | No Violations | Bill Mitton with Knox Energy called to inform me that the backside of the 8 surface casing had caved in approximately 15 feet down. He was called in a cement mixer to grout the backside of the casing from the surface with 9 sack grout. I witnessed this job and cement stayed at the surface. |
0731355902 | 2013-06-14 | Production Wells | No Violations | I witnessed this frac job for Knox Energy. Producers Service Corp. was contracted to frac this well. Refer to stimulation report for details. |
0790746894 | 2013-07-16 | Preliminary Restoration | No Violations | I inspected this well location today. The well was equipped with a pumping unit and motor. The well was pumping during inspection. The drilling pits were open. Knox Energy will be closing the pits this week. |
1278379918 | 2013-05-30 | Drill / Deepen / Reopen | No Violations | I witnessed the cementing of the 8 inch surface casing for Knox Energy on Kilbarger rig 5. Bill Mitton with Knox Energy was on location. Petroset Cementing was contracted to cement the casing. Circulation was established. Partial cement returns were observed. A cement basket was not installed. |
1372869555 | 2013-05-31 | Drill / Deepen / Reopen | No Violations | I inspected drilling operations today. Kilbarger rig #5 drilling on air with 7.88 bit. Depth approximately 1,680 feet during inspection. No violations this date. |
1435228971 | 2013-07-16 | Preliminary Restoration | No Violations | This inspection was conducted as a preliminary restoration status check. The well was equipped with a pumping unit and motor. The pits used during drilling have not been closed. Knox Energy will be closing the pits this week . |
1599051356 | 2013-05-29 | Drill / Deepen / Reopen | No Violations | I inspected drilling operations today. Kilbarger rig 5 drilling on fluid during inspection. Depth was approximately 287 feet. No violations this date. |
For data sources see[9]