Well Details

Well ID: 34-031-24740
Loading map...
Country: United States
State: Ohio
County: Coshocton
Municipality: Newcastle Township
Operator Name: ELSAAN ENERGY LLC
Well Pad ID:
Farm/Lease Name: RINGWALT H& L
License Status: Producing
License Date: 1982-08-05
Spud Date: 1982-12-30
Spud Drilling Contractor: SERVICE RIG
Final Drill Date: 1983-01-11
Well Total Depth: 3425 ft
Configuration: Vertical
Latitude: 40.310497424
Longitude: -82.15722947

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1982-08-05 Issued Date 8/5/82 Expired Date 2/1/83 Acres 0020000 Tool Type CT Proposed Formation CLINTON Proposed Depth 03425 Proposed Drill Depth 03425
Original Spud 1982-12-30
Completed 1983-01-11
Reached Total Depth 1983-01-11
Construction Permit Expires 1983-02-01
CO 1983-02-12 303 TIME ENERGY INC GeoDate 8/5/82
Completion Report Received 1983-03-14
Change of Owner 2006-06-28 Operator changed from 303, TIME ENERGY INC to 8053, RINGWALT HARRY J
Change of Owner 2013-10-16 Operator changed from 8053, RINGWALT HARRY J to 8163, ELSAAN ENERGY LLC
Correction to Well 2015-05-01 CHANGE IN WELL NUMBER
Record Last Modified 2019-04-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3296 3386 0
2006-09-11 3356 3363 8

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
FOAM 0 9160 Gal 25000 FRAC;10MG H2O,25M# SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 EDCO DRILLING & PRODUCING 395 147 0
2014 ELSAAN ENERGY LLC 0 0 0
2015 ELSAAN ENERGY LLC 0 0 365
2016 ELSAAN ENERGY LLC 0 0 365
2017 ELSAAN ENERGY LLC 0 32 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 EDCO DRILLING & PRODUCING Brine 0 0
2014 ELSAAN ENERGY LLC Brine 0 0
2015 ELSAAN ENERGY LLC Brine 0 365
2016 ELSAAN ENERGY LLC Brine 0 365
2017 ELSAAN ENERGY LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0001252i54 2002-02-07 Orphan Violations Noted arrived on site and found well to be idle, cannot locate company.
0005495637 2002-02-07 Orphan No Violations arrived on site and found well to be idle, cannot locate company.
0872514649 2013-02-20 Production Wells Violations Noted On the day of my inspection I found that the well head was equipped with a pumping unit. The tank battery consisted of one 100 barrel stock tank, one 20 barrel poly brine tank and an earthen dike. There were no leaks or spills at the well head or tank battery. There was no identification posted. Ohio Administrative Code 1501:9-9-05(A)10 states that all producing leases shall be legibly identified in a conspicuous place on or near the well-head or the storage tank(s) as to owner, lease name, well number, permit number, county, and emergency telephone number.
1040939123 2013-04-15 Production Wells No Violations FOLLOW UP TO CA #872514649: On the day of my inspection I found that proper identification was posted. This violation is resolved.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0001252i54 US-OH-106800 2002-03-04 Defective casing, leaking well
0872514649 US-OH-129937 2013-04-15 Failure to legibly identify well

For data sources see[9]

References