Well Details

Well ID: 34-031-26849
Loading map...
Country: United States
State: Ohio
County: Coshocton
Municipality: Jefferson Township
Operator Name: LBJ DRILLING CO INC
Well Pad ID:
Farm/Lease Name: W.C.M.A.
License Status: Producing
License Date: 2013-08-13
Spud Date: 2001-11-13
Spud Drilling Contractor: PROFESSIONAL WELL SVC-PWS
Final Drill Date: 2001-11-17
Well Total Depth: 3496 ft
Configuration: Vertical
Latitude: 40.335288160
Longitude: -81.99576649

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2001-11-01 1637 MACKENCO INC Proposed Formation CLINTON Issued Date 11/1/2001 Expired Date 11/1/2002 6:00:00 AM
Original Spud 2001-11-13 RBDMS Rec
Completed 2001-11-17 RBDMS Rec
Reached Total Depth 2001-11-17 RBDMS Rec
Completion Report Received 2002-01-18 RBDMS Rec
APP 2011-03-25 Proposed Formations:CLINTON, Issued Date:3/25/2011, Expired Date:3/24/2013 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:
APP 2013-08-13 Proposed Formations:CLINTON, Issued Date:8/13/2013, Expired Date:8/13/2015 12:00:00 PM, Drilling unit acres:20.22, Proposed Well Type:OG, Proposed Well Class:
Change of Owner 2014-10-21 Operator changed from 1637, MACKENCO INC to 226, LBJ DRILLING CO INC
Construction Permit Expires 2015-08-13 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2002-03-01 3304 3374 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 69600 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 MACKENCO INC 0 224 15
2002 MACKENCO INC 9854 1060 365
2003 MACKENCO INC 2395 303 365
2004 MACKENCO INC 897 280 365
2005 MACKENCO INC 432 147 365
2006 MACKENCO INC 274 149 365
2007 MACKENCO INC 156 150 365
2008 MACKENCO INC 0 131 365
2009 MACKENCO INC 0 141 365
2010 MACKENCO INC 0 72 365
2011 MACKENCO INC 1871 0 365
2012 MACKENCO INC 0 76 366
2013 MACKENCO INC 0 75 365
2014 LBJ DRILLING CO INC 187 0 365
2016 LBJ DRILLING CO INC 0 62 365
2017 LBJ DRILLING CO INC 0 126 365
2018 LBJ DRILLING CO INC 0 72 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 MACKENCO INC Brine 0 15
2002 MACKENCO INC Brine 135 365
2003 MACKENCO INC Brine 30 365
2004 MACKENCO INC Brine 0 365
2005 MACKENCO INC Brine 0 365
2006 MACKENCO INC Brine 0 365
2007 MACKENCO INC Brine 25 365
2008 MACKENCO INC Brine 0 365
2009 MACKENCO INC Brine 20 365
2010 MACKENCO INC Brine 0 365
2011 MACKENCO INC Brine 0 365
2012 MACKENCO INC Brine 0 366
2013 MACKENCO INC Brine 0 365
2014 LBJ DRILLING CO INC Brine 0 365
2016 LBJ DRILLING CO INC Brine 0 365
2017 LBJ DRILLING CO INC Brine 0 365
2018 LBJ DRILLING CO INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
001287i711 2002-05-03 Preliminary Restoration No Violations pits closed , well in production.
0878090089 2006-02-01 Production Wells No Violations Well in production .
1043065520 2013-09-12 Production Wells No Violations On the day of my inspection I found that the well head was equipped with a pumping unit. The tank battery consisted of two 100 barrel stock tanks, one 30 barrel brine tank, one separator and an earthen dike. Proper identification was posted and there were no leaks or spills. Both the pumping unit and tank battery were fenced with chain link and three-strand barbed wire. No violations at this time.

For data sources see[9]

References