Well Details

Well ID: 34-155-23873
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Liberty Township
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: WALLEY
License Status: Producing
License Date: 2007-07-30
Spud Date: 2007-08-04
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2007-08-09
Well Total Depth: 5336 ft
Configuration: Vertical
Latitude: 41.156749875
Longitude: -80.62304987

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-07-30 Proposed Formations:CLINTON, Issued Date:7/30/2007, Expired Date:7/29/2008 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-08-09
Reached Total Depth 2007-08-09
Completion Report Received 2007-10-01
Construction Permit Expires 2008-07-29
Record Last Modified 2015-09-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-01-02 4986 5068 50
2008-01-02 5148 5160 11

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2500 Bbl 50000 THIS FRAC TREATMENT INCLUDES THE MEDINA SANDSTONE

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 PAC DRILLING LLC 27448 461 347
2009 PAC DRILLING LLC 20897 256 354
2010 PAC DRILLING LLC 15849 247 344
2011 PAC DRILLING LLC 6342 124 341
2012 PAC DRILLING LLC 4158 155 363
2013 PAC DRILLING LLC 3128 130 365
2014 PAC DRILLING LLC 2462 120 360
2015 PAC DRILLING LLC 2134 51 360
2016 PAC DRILLING LLC 2598 78 358
2017 PAC DRILLING LLC 3058 131 359
2018 PAC DRILLING LLC 2700 51 359

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 PAC DRILLING LLC Brine 75 347
2009 PAC DRILLING LLC Brine 67 354
2010 PAC DRILLING LLC Brine 68 344
2011 PAC DRILLING LLC Brine 30 341
2012 PAC DRILLING LLC Brine 49 363
2013 PAC DRILLING LLC Brine 5 365
2014 PAC DRILLING LLC Brine 25 360
2015 PAC DRILLING LLC Brine 21 360
2016 PAC DRILLING LLC Brine 15 358
2017 PAC DRILLING LLC Brine 22 359
2018 PAC DRILLING LLC Brine 0 359

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0026919163 2014-05-26 UrbanProduction Wells No Violations I was on location to perform a status check inspection. I found during my inspection the well equipped with a plunger lift unit that was in production. The tank battery consisted of a 210 barrel production tank, a 50 barrel, poly brine tank and a separator. A dike surrounded the tank battery. Identification signs were posted at the well and tank battery. There was a wooden fence around the production equipment and a locked, chain link fence around the well. The door to the wooden fence was lying on the ground. A bull plug was installed on the load line. There was no urban safety equipment on the production tank. The lease road was in good condition. I called PAC Drilling and instructed Gus to:

Install the required safety equipment by 9/26/2014 Repair the wooden door on the fencing surrounding the production equipment A follow-up inspection will be performed by 9/29/2014.

0079554623 2019-02-04 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1845806637, regarding multiple compliance issues related to urban rule requirements. At the time of this inspection, the well fence man door still needed a lock. The brine tank valve leak was not actively leaking, at the time of this inspection, but the tank did not appear to be repaired. The required urban safety equipment was still missing from the production tank, and needs to be installed per 1501:9-9-05E(4)(b-e). There was a wooden fence with no lock around the tank battery. Install a lock on the tank battery fence. The identification sign was missing the required information per 1501:9-9-05E(1)(a-e). Landscaping at the tank battery has not been installed per 1501:9-9-05(E)(6)(a-c).

PAC needs to: 1) Install locks on the well and tank battery man doors. 2) Post an identification sign to be in compliance with 1501:9-9-05E(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 3) Install urban safety equipment on the production tank as required by 1501:9-9-05E(4)(b-e): Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor 4) Install the landscaping at the tank battery location as required per 1501:9-9-05(E)(6)(a-c).

0114085144 2017-02-15 UrbanProduction Wells No Violations

--9-05(E)(1)(a-

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). -up lines or remove the handles per 1501:9-9-05(E)(3) 4) Repair or build a new dike around the tank battery. 5) Secure both fences at the tank batte

0187937315 2011-09-20 Preliminary Restoration No Violations Preliminary restoration was completed.
0805592598 2011-09-16 Production Wells No Violations The flow line was leaking gas. I notified the well owner that repairs were necessary on this line.
0886796244 2017-09-07 UrbanProduction Wells No Violations

---3874. I spoke with Rusty Thornhill to add locks to the fences around the tank battery and well, install a plug on the 2 nipple, and install the urban safety equipment.

1448042241 2018-07-16 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1845806637. At the time of this inspection, the fence man door still needed a lock. Inside the diked tank battery, the pick-up line has a plug, but was leaking brine around the elbow connection on the line. Salt crystals had formed along the length of the pick-up line. The required urban safety equipment was still missing from the production tank, and needs to be installed per 1501:9-9--e). There was a wooden fence with no lock around the tank battery. Install a lock on the tank battery fence. The identification sign was missing the required information per 1501:9-9--e). Landscaping at the tank battery has not been installed. The tank battery is shared with permit 2-3874. I contacted Rusty Hornhill of PAC Drilling, LLC about addressing the leak on the pick-up line and cleaning up any impacted soil from the brine leak.
1687743927 2007-08-07 Drill / Deepen / Reopen No Violations Kilbarger drilling at 4297 .
1846806637 2018-05-11 UrbanProduction Wells Violations Noted At the time of this inspection, the well was equipped with a plunger lift assembly. The annulus and flow line valves were open. There was an identification posted on the chain link fence that surrounds the well with no lock. A lock needs installed at the well fence. The tank battery has two storage tanks and a separator. The dike has been rebuilt on the north end of the tank battery. The pick-up line has a plug, but a missing lock. The required urban safety equipment was missing from the production tank, and needs to be installed per 1501:9-9--e). There was a wooden fence with no lock around the tank battery. Install a lock on the tank battery fence. The identification sign was missing the required information per 1501:9-9--e). There was no landscaping at the tank battery; however, the tank battery is located approximately 1,500 feet south of Route 304 on commercial/industrial property with trees and vegetation on the north and east sides. The access road was stable with no gate at the entrance. The access road was the entrance for several commercial/industrial businesses. The tank battery is shared with permit 2-3874.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1846806637 US-OH-118464 2018-05-25 9-05E1 ID (a-i)
1846806637 US-OH-118465 2018-05-25 9-05E3 LOCKS
1846806637 US-OH-118466 2018-05-25 9-05E4 TANKS (a-i)

For data sources see[9]

References