X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-059-24190"

m
m
Line 1: Line 1:
__TOC__
+
__TOC__
 
== Well Details ==
 
== Well Details ==
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-059-24190
 
| Well ID: 34-059-24190
| style="height=100%; align=center" rowspan="15" | {{#display_map: 39.87204764, -81.68388874 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 39.871975326, -81.68403873 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Guernsey County, Ohio|Guernsey]]
+
| Country: United States
 
|-
 
|-
| Municipality:  
+
| State: Ohio
 +
|-
 +
| County: [[Guernsey_County,_Ohio|Guernsey]]
 +
|-
 +
| Municipality: [[Spencer_Township,_Guernsey_County,_Ohio|Spencer Township]]
 
|-
 
|-
 
| Operator Name: [[ANADARKO E & P ONSHORE LLC]]
 
| Operator Name: [[ANADARKO E & P ONSHORE LLC]]
 
|-
 
|-
| Well Pad ID:  
+
| Well Pad ID: [[US-OH-000483]]
|-
 
| Farm/Lease Name:
 
 
|-
 
|-
| First Permit Date:  
+
| Farm/Lease Name: FREC GUER SPENCER
 
|-
 
|-
| Last Permit Date:  
+
| License Status: Plugged Back
 
|-
 
|-
| Spud Date: 2011-11-02
+
| License Date: 2011-09-07
 
|-
 
|-
| Unconventional: No
+
| Spud Date: 2011-09-26
 
|-
 
|-
| Configuration: Vertical
+
| Spud Drilling Contractor: [[KEY ENERGY]]
 
|-
 
|-
| Well Status: Producing
+
| Final Drill Date: 2011-11-01
 
|-
 
|-
| Violations: 0
+
| Well Total Depth: 6755 ft
 
|-
 
|-
| Latitude: 39.87204764
+
| Configuration: Vertical
 
|-
 
|-
| Longitude: -81.68388874
+
| Latitude: 39.871975326
 
|-
 
|-
 +
| Longitude: -81.68403873
 
|}
 
|}
== Production Data ==
+
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" style="text-align: center"| Well Status
!scope="col" | GAS QUANTITY
+
!scope="col" style="width: 15%;text-align: center"| Well Status Date
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" style="text-align: center"| Comment
!scope="col" | CONDENSATE QUANTITY
 
!scope="col" | CONDENSATE PRODUCTION DAYS
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL PRODUCTION DAYS
 
 
|-
 
|-
| 2012-0
+
| APP
| style="text-align:right;" | 41153.0
+
| 2011-09-07
 +
| Proposed Formations:TRENTON/BLACK RIVER, Issued Date:9/7/2011, Expired Date:9/6/2013 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
 +
|-
 +
| Reached Total Depth
 +
| 2011-11-01
 
|  
 
|  
 +
|-
 +
| Plugged Back
 +
| 2011-11-02
 
|  
 
|  
 +
|-
 +
| Completion Report Received
 +
| 2012-02-01
 
|  
 
|  
| style="text-align:right;" | 13564.0
+
|-
 +
| Construction Permit Expires
 +
| 2013-09-06
 
|  
 
|  
 
|-
 
|-
 +
| Record Last Modified
 +
| 2017-02-27
 +
|
 
|-
 
|-
| 2013-12
+
|}
| style="text-align:right;" | 6440.0
+
For data sources see<ref>{{cite web
|  
+
| title = Risk Based Data Management System - Well and WellHistry Tables
|  
+
|publisher = [[Ohio Department of Natural Resources]]
|  
+
| date =  2019-05-07
| style="text-align:right;" | 283.0
+
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
|  
+
| accessdate = 2019-05-21 }}</ref>
 +
== Perforation Treatments ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Perforation Date
 +
!scope="col" style="text-align: center"| Interval Top (ft)
 +
!scope="col" style="text-align: center"| Interval Base (ft)
 +
!scope="col" style="text-align: center"| Number of Shots
 +
|-
 +
| 2012-04-30
 +
| style="text-align: right;" | 8334
 +
| style="text-align: right;" | 8118
 +
| style="text-align: right;" | 40
 +
|-
 +
| 2012-04-30
 +
| style="text-align: right;" | 8072
 +
| style="text-align: right;" | 7860
 +
| style="text-align: right;" | 40
 +
|-
 +
| 2012-04-30
 +
| style="text-align: right;" | 8842
 +
| style="text-align: right;" | 8626
 +
| style="text-align: right;" | 40
 +
|-
 +
| 2012-04-30
 +
| style="text-align: right;" | 8588
 +
| style="text-align: right;" | 8372
 +
| style="text-align: right;" | 40
 
|-
 
|-
 +
| 2012-04-30
 +
| style="text-align: right;" | 7318
 +
| style="text-align: right;" | 7102
 +
| style="text-align: right;" | 40
 
|-
 
|-
| 2013-3
+
| 2012-04-30
| style="text-align:right;" | 6282.0
+
| style="text-align: right;" | 7064
|  
+
| style="text-align: right;" | 6848
|
+
| style="text-align: right;" | 40
|  
 
| style="text-align:right;" | 1538.0
 
|
 
 
|-
 
|-
 +
| 2012-04-30
 +
| style="text-align: right;" | 7826
 +
| style="text-align: right;" | 7610
 +
| style="text-align: right;" | 40
 
|-
 
|-
| 2013-6
+
| 2012-04-30
| style="text-align:right;" | 12124.0
+
| style="text-align: right;" | 7572
|  
+
| style="text-align: right;" | 7356
|
+
| style="text-align: right;" | 40
|  
 
| style="text-align:right;" | 1042.0
 
|
 
 
|-
 
|-
 +
| 2012-04-30
 +
| style="text-align: right;" | 10362
 +
| style="text-align: right;" | 10156
 +
| style="text-align: right;" | 40
 
|-
 
|-
| 2013-9
+
| 2012-04-30
| style="text-align:right;" | 15190.0
+
| style="text-align: right;" | 10106
|  
+
| style="text-align: right;" | 10104
|
+
| style="text-align: right;" | 40
|  
 
| style="text-align:right;" | 763.0
 
|
 
 
|-
 
|-
 +
| 2012-04-30
 +
| style="text-align: right;" | 10874
 +
| style="text-align: right;" | 10658
 +
| style="text-align: right;" | 40
 
|-
 
|-
| 2014-3
+
| 2012-04-30
| style="text-align:right;" | 22709.0
+
| style="text-align: right;" | 10618
| style="text-align:right;" | 92.0
+
| style="text-align: right;" | 10404
|
+
| style="text-align: right;" | 40
|
 
| style="text-align:right;" | 567.0
 
| style="text-align:right;" | 92.0
 
 
|-
 
|-
 +
| 2012-04-30
 +
| style="text-align: right;" | 9342
 +
| style="text-align: right;" | 9130
 +
| style="text-align: right;" | 40
 
|-
 
|-
| 2014-4
+
| 2012-04-30
| style="text-align:right;" | 17291.0
+
| style="text-align: right;" | 9096
| style="text-align:right;" | 92.0
+
| style="text-align: right;" | 8880
|
+
| style="text-align: right;" | 40
|
 
| style="text-align:right;" | 406.0
 
| style="text-align:right;" | 92.0
 
 
|-
 
|-
 +
| 2012-04-30
 +
| style="text-align: right;" | 9852
 +
| style="text-align: right;" | 9646
 +
| style="text-align: right;" | 40
 
|-
 
|-
| 2015-1
+
| 2012-04-30
| style="text-align:right;" | 20376.0
+
| style="text-align: right;" | 9624
| style="text-align:right;" | 90.0
+
| style="text-align: right;" | 9388
|
+
| style="text-align: right;" | 40
|
 
| style="text-align:right;" | 709.0
 
| style="text-align:right;" | 90.0
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Ohio Department of Natural Resources RBDMS
+
  | title = Risk Based Data Management System - Perfs Table
  | publisher = [http://oilandgas.ohiodnr.gov/]
+
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2015-06-19
+
  | date = 2019-05-07
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Production
+
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2015-06-20 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
== Inspection Data ==
+
== Fracking Activities ==
 +
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" style="text-align: center"| Job Number
!scope="col" | DATE
+
!scope="col" style="text-align: center"| Job Start Date
!scope="col" | DESCRIPTION
+
!scope="col" style="text-align: center"| Job End Date
!scope="col" | COMMENT
+
!scope="col" style="text-align: center"| True Vertical Depth (ft)
!scope="col" | VIOLATION ID
+
!scope="col" style="text-align: center"| Total Water Volume (gal)
!scope="col" | VIOLATION CODE
+
!scope="col" style="text-align: center"| Total Non-Water Volume (gal)
!scope="col" | VIOLATION COMMENT
 
 
|-
 
|-
| -1025609309
+
| 1
| 2011-10-17
+
| 01/25/2012
 +
| 01/25/2012
 +
| style="text-align: right;" | 6520.00
 +
| style="text-align: right;" | 5,205,007.0
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" style="width: 100%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Trade Name
 +
!scope="col" style="text-align: center"| Supplier
 +
!scope="col" style="text-align: center"| Purpose
 +
!scope="col" style="text-align: center"| Ingredient Name
 +
!scope="col" style="white-space: nowrap;text-align: center"| CAS Number
 +
!scope="col" style="text-align: center"| Additive Percentage by Mass
 +
!scope="col" style="text-align: center"| Job Percentage by Mass
 +
!scope="col" style="text-align: center"| Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="29"| 1
 +
| rowspan="1"| WBE-6
 +
| rowspan="1"| Trican Well Service
 +
| rowspan="1"| Gel Breaker
 +
| No hazardous ingredients
 
|  
 
|  
| Spud meeting at well site with rig crew and service personnel.
+
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| TXP-8
 +
| rowspan="1"| Trican Well Service
 +
| rowspan="1"| Friction Reducer
 +
| Cationic water-soluble polymer emulsion
 
|  
 
|  
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.07
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="4"| CS-1
 +
| rowspan="4"| Trican Well Service
 +
| rowspan="4"| Clay Stabilizer
 +
| 1,2-Propylene glycol
 +
| 57-55-6
 +
| style="text-align: right;" | 20.00
 +
| style="text-align: right;" | 0.03
 +
| style="text-align: right;" |
 +
|-
 +
| Inorganic salts
 
|  
 
|  
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.05
 +
| style="text-align: right;" |
 +
|-
 +
| Surfactant
 
|  
 
|  
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00932000
 +
| style="text-align: right;" |
 
|-
 
|-
 +
| Blend
 +
|
 +
| style="text-align: right;" | 25.00
 +
| style="text-align: right;" | 0.04
 +
| style="text-align: right;" |
 
|-
 
|-
| 1317069975
+
|- valign="top"
| 2011-09-26
+
| rowspan="1"| DF-1
 +
| rowspan="1"| Trican Well Service
 +
| rowspan="1"| Defoaming Agent
 +
| Non-hazardous materials only in the product
 
|  
 
|  
| Zigenfuess Drilling on site to set conductor and intermediate pipe to 500' should be cementing 16 casing later on in week.
+
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.00081000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="0"| Acid, Hydrochloric (7.5)
 +
| rowspan="0"|
 +
| rowspan="0"| General Acidizing
 +
|- valign="top"
 +
| rowspan="0"| Acid, Hydrochloric (15)
 +
| rowspan="0"|
 +
| rowspan="0"| General Acidizing
 +
|- valign="top"
 +
| rowspan="1"| BXL-A
 +
| rowspan="1"| Trican Well Service
 +
| rowspan="1"| Gel Breaker
 +
| Proprietary
 
|  
 
|  
 +
| style="text-align: right;" | 70.00
 +
| style="text-align: right;" | 0.00826000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| WXB-10
 +
| rowspan="2"| Trican Well Service
 +
| rowspan="2"| Fracturing Crosslinker
 +
| Distillates, petroleum, hydrotreated light
 +
| 64742-47-8
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.02
 +
| style="text-align: right;" |
 +
|-
 +
| Ulexite
 +
| 1319-33-1
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.02
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| AI-7NR
 +
| rowspan="1"| Trican Well Service
 +
| rowspan="1"| Corrosion Inhibitor
 +
| Propargyl alcohol
 +
| 107-19-7
 +
| style="text-align: right;" | 1.00
 +
| style="text-align: right;" | 0.00003000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="0"| Sand (Proppant)
 +
| rowspan="0"| Trican Well Service
 +
| rowspan="0"| Proppant
 +
|- valign="top"
 +
| rowspan="2"| Sand (Proppant)
 +
| rowspan="2"|
 +
| rowspan="2"| Proppant
 +
| Quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 70.00
 +
| style="text-align: right;" | 8.80
 +
| style="text-align: right;" |
 +
|-
 +
| Methenamine
 +
| 100-97-0
 +
| style="text-align: right;" | 1.00
 +
| style="text-align: right;" | 0.12
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| WBO-2
 +
| rowspan="1"| Trican Well Service
 +
| rowspan="1"| Gel Breaker
 +
| Sodium persulfate
 +
| 7775-27-1
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.00588000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| Acid, Hydrochloric (7.5)
 +
| rowspan="2"| Trican Well Service
 +
| rowspan="2"| General Acidizing
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 92.50
 +
| style="text-align: right;" | 0.36
 +
| style="text-align: right;" |
 +
|-
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 7.50
 +
| style="text-align: right;" | 0.02
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| BioClear 5000
 +
| rowspan="2"| Trican Well Service
 +
| rowspan="2"| Biocide
 +
| 2,2-Dibromo-3-nitrilopropionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00257000
 +
| style="text-align: right;" |
 +
|-
 +
| Polyethylene glycol
 +
| 25322-68-3
 +
| style="text-align: right;" | 70.00
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| GBO-1
 +
| rowspan="1"| Trican Well Service
 +
| rowspan="1"| Gel Breaker
 +
| Sodium perborate tetrahydrate
 +
| 10486-00-7
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| WG-111D
 +
| rowspan="1"| Trican Well Service
 +
| rowspan="1"| Water Gellant
 +
| Guar gum
 +
| 9000-30-0
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.05
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Water
 +
| rowspan="1"| Anadarko
 +
| rowspan="1"| Carrier/Base Fluid
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 86.39
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| Acid, Hydrochloric (15)
 +
| rowspan="2"| Trican Well Service
 +
| rowspan="2"| General Acidizing
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 15.00
 +
| style="text-align: right;" | 0.03
 +
| style="text-align: right;" |
 +
|-
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 85.00
 +
| style="text-align: right;" | 0.17
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="4"| TXP-10
 +
| rowspan="4"| Trican Well Service
 +
| rowspan="4"| Scale Inhibitor
 +
| 1,2-Propylene glycol
 +
| 57-55-6
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00235000
 +
| style="text-align: right;" |
 +
|-
 +
| Acrylate phosphonate copolymer
 
|  
 
|  
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.00939000
 +
| style="text-align: right;" |
 +
|-
 +
| Neutralized organic acid
 
|  
 
|  
 +
| style="text-align: right;" | 20.00
 +
| style="text-align: right;" | 0.00469000
 +
| style="text-align: right;" |
 +
|-
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 70.00
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="2"| FEAC-20
 +
| rowspan="2"| Trican Well Service
 +
| rowspan="2"| Iron Control
 +
| Citric acid
 +
| 77-92-9
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00213000
 +
| style="text-align: right;" |
 
|-
 
|-
| 1317411697
+
| Acetic acid
| 2011-09-30
+
| 64-19-7
|  
+
| style="text-align: right;" | 50.00
| Setting 24 casing@360' will possibly set 16 late tomorrow afternoon.
+
| style="text-align: right;" | 0.00355000
|  
+
| style="text-align: right;" |  
|  
 
|  
 
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 +
<!--== Stimulations Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Stimulation Date
 +
!scope="col" style="text-align: center"| Chemical Agent
 +
!scope="col" style="text-align: center"| Chemical Agent Concentration (%)
 +
!scope="col" style="text-align: center"| Fracking Fluid Volume
 +
!scope="col" style="text-align: center"| Mass of Proppant Used (lb)
 +
!scope="col" style="text-align: center"| Fracking Company
 +
!scope="col" style="text-align: center"| Comments
 
|-
 
|-
| 1319491047
+
|}-->
| 2011-10-21
+
<!--== Production Data ==
|  
+
{| class="wikitable sortable" width="95%"
| On site to witness testing of BOP by Greene's Energy Group.  Annular was tested at @ 3500 PSI and blind ram was tested at @ 5000 PSI.  Pipe ram and choke system were also tested @ 5000 PSI.  All equipment for BOP passed test.
+
!scope="col" style="text-align: center"| Period
|  
+
!scope="col" style="text-align: center"| Operator Name
|  
+
!scope="col" style="text-align: center"| Gas Quantity (mcf)
|  
+
!scope="col" style="text-align: center"| Oil Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
|}-->
 +
== Waste Data ==
 +
{| class="wikitable sortable"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Waste Type
 +
!scope="col" style="text-align: center"| Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 
|-
 
|-
 +
| 2012
 +
| [[ANADARKO E & P ONSHORE LLC]]
 +
| Brine
 +
| style="text-align: right;" | 11704
 +
| style="text-align: right;" | 293
 
|-
 
|-
| -1603889048
+
| 2013
| 2011-11-21
+
| [[ANADARKO E & P ONSHORE LLC]]
|  
+
| Brine
|  
+
| style="text-align: right;" | 4287
|  
+
| style="text-align: right;" | 323
|  
 
|  
 
 
|-
 
|-
 +
| 2014
 +
| [[ARTEX OIL COMPANY]]
 +
| Brine
 +
| style="text-align: right;" | 2224
 +
| style="text-align: right;" | 345
 
|-
 
|-
| -1667347511
+
| 2015
| 2011-11-21
+
| [[ARTEX OIL COMPANY]]
|  
+
| Brine
| Total depth was reached at 10,962'.  Will condition wellbore and then log well and possibly run casing later on in the week.
+
| style="text-align: right;" | 1656
|  
+
| style="text-align: right;" | 365
|  
 
|  
 
 
|-
 
|-
 +
| 2016
 +
| [[ARTEX OIL COMPANY]]
 +
| Brine
 +
| style="text-align: right;" | 1213
 +
| style="text-align: right;" | 366
 
|-
 
|-
| -1920651845
+
| 2017
| 2012-02-22
+
| [[ARTEX OIL COMPANY]]
|  
+
| Brine
| Stopped by drill site for update they were flowing well back into 500 bbl tanks and hauling water to UIC facility for proper disposal.
+
| style="text-align: right;" | 745
|  
+
| style="text-align: right;" | 365
|  
 
|  
 
 
|-
 
|-
 +
| 2018
 +
| [[ARTEX OIL COMPANY]]
 +
| Brine
 +
| style="text-align: right;" | 1049
 +
| style="text-align: right;" | 365
 
|-
 
|-
| -2059153676
+
| 2019
| 2011-10-12
+
| [[ARTEX OIL COMPANY]]
|  
+
| Brine
| Invited to attend pre-spud meeting held by company
+
| style="text-align: right;" | 150
|  
+
| style="text-align: right;" | 90
|  
 
|  
 
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Production Table - Brine Data
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
<ref>{{cite web
 +
| title = Combined Production - Brine Data
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date = 2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Inspection Date
 +
!scope="col" style="text-align: center"| Inspection Type
 +
!scope="col" style="text-align: center"| Inspection Result
 +
!scope="col" style="text-align: center"| Inspection Comments
 
|-
 
|-
| 33154408
+
| 0033154408
 
| 2011-09-28
 
| 2011-09-28
|  
+
| Drill / Deepen /  Reopen
| Drilling 24 conductor hole they were@180' they propose to set 200'+- hopefully by tomorrow.
+
| No Violations
|
+
| Drilling 24 conductor hole they were@180 they propose to set 200+- hopefully by tomorrow.
|
 
|
 
 
|-
 
|-
 +
| 0095110996
 +
| 2011-11-22
 +
| Drill / Deepen /  Reopen
 +
| No Violations
 +
| Casing crew rigging up to run production casing.  Owner is going to run split string of casing - 4.5 casing through lateral and 5.5 casing in vertical section.  Top of cement will be brought up into the intermediate casing string.
 
|-
 
|-
| -596583758
+
| 0596583758
 
| 2012-02-29
 
| 2012-02-29
|  
+
| Completion Testing
 +
| No Violations
 
| Stopped by site for update they were still flowing well back to 500 bbl storage tanks and also were flaring gas through flare stack.
 
| Stopped by site for update they were still flowing well back to 500 bbl storage tanks and also were flaring gas through flare stack.
|
 
|
 
|
 
 
|-
 
|-
 +
| 0748635310
 +
| 2014-06-05
 +
| Preliminary Restoration
 +
| No Violations
 +
| On the day of my inspection the site passed preliminary restoration according to 1509.072A.
 
|-
 
|-
| -748635310
+
| 0892561045
 
| 2014-06-05
 
| 2014-06-05
|  
+
| Preliminary Restoration
 +
| No Violations
 
| On the day of my inspection the site passed preliminary restoration according to 1509.072A.
 
| On the day of my inspection the site passed preliminary restoration according to 1509.072A.
|
 
|
 
|
 
 
|-
 
|-
 +
| 0911481254
 +
| 2015-12-07
 +
| Production Wells
 +
| No Violations
 +
| On the day of my inspection I witnessed that the production equipment included a sand trap, a GP Unit, a stabilizer unit, 2 compressors, a combustor and 6-400bbl tanks within containment and shared with 345059242000000 Frec Spencer A-5H. The well was equipped with a Weatherford pumping unit powered by electricity with valves in the open position.
 +
|-
 +
| 1006414026
 +
| 2017-02-27
 +
| Production Wells
 +
| No Violations
 +
| On the day of my inspection I witnessed that the production equipment included a GP Unit. Also present a stabilizer unit, 2 compressors, a vapor recovery system, a combustor and 6-400 barrel tanks within containment and shared with 345059242000000 Frec Spencer A-5H. The well was equipped with a Weatherford pumping unit powered by electricity with valves in the open position. Identification was present and production records were current.
 +
|-
 +
| 1025609309
 +
| 2011-10-17
 +
| Drill / Deepen /  Reopen
 +
| No Violations
 +
| Spud meeting at well site with rig crew and service personnel.
 +
|-
 +
| 1317069975
 +
| 2011-09-26
 +
| Drill / Deepen /  Reopen
 +
| No Violations
 +
| Zigenfuess Drilling on site to set conductor and intermediate pipe to 500 should be cementing 16 casing later on in week.
 +
|-
 +
| 1317411697
 +
| 2011-09-30
 +
| Drill / Deepen /  Reopen
 +
| No Violations
 +
| Setting 24 casing@360 will possibly set 16 late tomorrow afternoon.
 +
|-
 +
| 1319491047
 +
| 2011-10-21
 +
| Drill / Deepen /  Reopen
 +
| No Violations
 +
| On site to witness testing of BOP by Greenes Energy Group.  Annular was tested at @ 3500 PSI and blind ram was tested at @ 5000 PSI.  Pipe ram and choke system were also tested @ 5000 PSI.  All equipment for BOP passed test.
 +
|-
 +
| 1467379990
 +
| 2016-07-01
 +
| Production Wells
 +
| No Violations
 +
| On the day of my inspection I witnessed that the production equipment included a GP Unit. Also present a stabilizer unit, 2 compressors, a vapor recovery system, a combustor and 6-400bbl tanks within containment and shared with 345059242000000 Frec Spencer A-5H. The well was equipped with a Weatherford pumping unit powered by electricity with valves in the open position. Identification was present and production records were current.
 
|-
 
|-
| -892561045
+
| 1603889048
| 2014-06-05
+
| 2011-11-21
|
+
| Drill / Deepen /  Reopen
| On the day of my inspection the site passed preliminary restoration according to 1509.072A.
+
| No Violations
|  
 
|  
 
 
|  
 
|  
 
|-
 
|-
 +
| 1667347511
 +
| 2011-11-21
 +
| Drill / Deepen /  Reopen
 +
| No Violations
 +
| Total depth was reached at 10,962.  Will condition wellbore and then log well and possibly run casing later on in the week.
 +
|-
 +
| 1920651845
 +
| 2012-02-22
 +
| Completion Testing
 +
| No Violations
 +
| Stopped by drill site for update they were flowing well back into 500 bbl tanks and hauling water to UIC facility for proper disposal.
 
|-
 
|-
| -95110996
+
| 2059153676
| 2011-11-22
+
| 2011-10-12
|  
+
| Drill / Deepen /  Reopen
| Casing crew rigging up to run production casing.  Owner is going to run split string of casing - 4.5 casing through lateral and 5.5 casing in vertical sectionTop of cement will be brought up into the intermediate casing string.
+
| No Violations
|
+
| Invited to attend pre-- went over over-all plan for well and how it would happenMet many of the people I would be working with in Morgan Co.
|
 
|
 
 
|-
 
|-
 
|}
 
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Violation ID
 +
!scope="col" style="text-align: center"| Violation Date
 +
!scope="col" style="text-align: center"| Violation Code
 +
!scope="col" style="text-align: center"| Violation Comments
 +
|-
 +
|}-->
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Ohio Department of Natural Resources RBDMS
+
  | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
  | publisher = [http://oilandgas.ohiodnr.gov/]
+
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2015-06-19
+
  | date = 2019-05-07
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection
+
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2015-06-20 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
== References ==
+
==References==
{{reflist}}
+
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Ohio Wells]]
 +
[[Category:FracFocus]]

Revision as of 20:07, 30 July 2019

Well Details

Well ID: 34-059-24190
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Spencer Township
Operator Name: ANADARKO E & P ONSHORE LLC
Well Pad ID: US-OH-000483
Farm/Lease Name: FREC GUER SPENCER
License Status: Plugged Back
License Date: 2011-09-07
Spud Date: 2011-09-26
Spud Drilling Contractor: KEY ENERGY
Final Drill Date: 2011-11-01
Well Total Depth: 6755 ft
Configuration: Vertical
Latitude: 39.871975326
Longitude: -81.68403873

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-09-07 Proposed Formations:TRENTON/BLACK RIVER, Issued Date:9/7/2011, Expired Date:9/6/2013 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
Reached Total Depth 2011-11-01
Plugged Back 2011-11-02
Completion Report Received 2012-02-01
Construction Permit Expires 2013-09-06
Record Last Modified 2017-02-27

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2012-04-30 8334 8118 40
2012-04-30 8072 7860 40
2012-04-30 8842 8626 40
2012-04-30 8588 8372 40
2012-04-30 7318 7102 40
2012-04-30 7064 6848 40
2012-04-30 7826 7610 40
2012-04-30 7572 7356 40
2012-04-30 10362 10156 40
2012-04-30 10106 10104 40
2012-04-30 10874 10658 40
2012-04-30 10618 10404 40
2012-04-30 9342 9130 40
2012-04-30 9096 8880 40
2012-04-30 9852 9646 40
2012-04-30 9624 9388 40

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 01/25/2012 01/25/2012 6520.00 5,205,007.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 WBE-6 Trican Well Service Gel Breaker No hazardous ingredients 100.00 0.00
TXP-8 Trican Well Service Friction Reducer Cationic water-soluble polymer emulsion 100.00 0.07
CS-1 Trican Well Service Clay Stabilizer 1,2-Propylene glycol 57-55-6 20.00 0.03
Inorganic salts 30.00 0.05
Surfactant 5.00 0.00932000
Blend 25.00 0.04
DF-1 Trican Well Service Defoaming Agent Non-hazardous materials only in the product 100.00 0.00081000
Acid, Hydrochloric (7.5) General Acidizing
Acid, Hydrochloric (15) General Acidizing
BXL-A Trican Well Service Gel Breaker Proprietary 70.00 0.00826000
WXB-10 Trican Well Service Fracturing Crosslinker Distillates, petroleum, hydrotreated light 64742-47-8 60.00 0.02
Ulexite 1319-33-1 60.00 0.02
AI-7NR Trican Well Service Corrosion Inhibitor Propargyl alcohol 107-19-7 1.00 0.00003000
Sand (Proppant) Trican Well Service Proppant
Sand (Proppant) Proppant Quartz 14808-60-7 70.00 8.80
Methenamine 100-97-0 1.00 0.12
WBO-2 Trican Well Service Gel Breaker Sodium persulfate 7775-27-1 100.00 0.00588000
Acid, Hydrochloric (7.5) Trican Well Service General Acidizing Water 7732-18-5 92.50 0.36
Hydrochloric acid 7647-01-0 7.50 0.02
BioClear 5000 Trican Well Service Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 10.00 0.00257000
Polyethylene glycol 25322-68-3 70.00 0.01
GBO-1 Trican Well Service Gel Breaker Sodium perborate tetrahydrate 10486-00-7 100.00 0.00
WG-111D Trican Well Service Water Gellant Guar gum 9000-30-0 100.00 0.05
Water Anadarko Carrier/Base Fluid Water 7732-18-5 100.00 86.39
Acid, Hydrochloric (15) Trican Well Service General Acidizing Hydrochloric acid 7647-01-0 15.00 0.03
Water 7732-18-5 85.00 0.17
TXP-10 Trican Well Service Scale Inhibitor 1,2-Propylene glycol 57-55-6 10.00 0.00235000
Acrylate phosphonate copolymer 40.00 0.00939000
Neutralized organic acid 20.00 0.00469000
Water 7732-18-5 70.00 0.01
FEAC-20 Trican Well Service Iron Control Citric acid 77-92-9 30.00 0.00213000
Acetic acid 64-19-7 50.00 0.00355000

For data sources see[4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2012 ANADARKO E & P ONSHORE LLC Brine 11704 293
2013 ANADARKO E & P ONSHORE LLC Brine 4287 323
2014 ARTEX OIL COMPANY Brine 2224 345
2015 ARTEX OIL COMPANY Brine 1656 365
2016 ARTEX OIL COMPANY Brine 1213 366
2017 ARTEX OIL COMPANY Brine 745 365
2018 ARTEX OIL COMPANY Brine 1049 365
2019 ARTEX OIL COMPANY Brine 150 90

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0033154408 2011-09-28 Drill / Deepen / Reopen No Violations Drilling 24 conductor hole they were@180 they propose to set 200+- hopefully by tomorrow.
0095110996 2011-11-22 Drill / Deepen / Reopen No Violations Casing crew rigging up to run production casing. Owner is going to run split string of casing - 4.5 casing through lateral and 5.5 casing in vertical section. Top of cement will be brought up into the intermediate casing string.
0596583758 2012-02-29 Completion Testing No Violations Stopped by site for update they were still flowing well back to 500 bbl storage tanks and also were flaring gas through flare stack.
0748635310 2014-06-05 Preliminary Restoration No Violations On the day of my inspection the site passed preliminary restoration according to 1509.072A.
0892561045 2014-06-05 Preliminary Restoration No Violations On the day of my inspection the site passed preliminary restoration according to 1509.072A.
0911481254 2015-12-07 Production Wells No Violations On the day of my inspection I witnessed that the production equipment included a sand trap, a GP Unit, a stabilizer unit, 2 compressors, a combustor and 6-400bbl tanks within containment and shared with 345059242000000 Frec Spencer A-5H. The well was equipped with a Weatherford pumping unit powered by electricity with valves in the open position.
1006414026 2017-02-27 Production Wells No Violations On the day of my inspection I witnessed that the production equipment included a GP Unit. Also present a stabilizer unit, 2 compressors, a vapor recovery system, a combustor and 6-400 barrel tanks within containment and shared with 345059242000000 Frec Spencer A-5H. The well was equipped with a Weatherford pumping unit powered by electricity with valves in the open position. Identification was present and production records were current.
1025609309 2011-10-17 Drill / Deepen / Reopen No Violations Spud meeting at well site with rig crew and service personnel.
1317069975 2011-09-26 Drill / Deepen / Reopen No Violations Zigenfuess Drilling on site to set conductor and intermediate pipe to 500 should be cementing 16 casing later on in week.
1317411697 2011-09-30 Drill / Deepen / Reopen No Violations Setting 24 casing@360 will possibly set 16 late tomorrow afternoon.
1319491047 2011-10-21 Drill / Deepen / Reopen No Violations On site to witness testing of BOP by Greenes Energy Group. Annular was tested at @ 3500 PSI and blind ram was tested at @ 5000 PSI. Pipe ram and choke system were also tested @ 5000 PSI. All equipment for BOP passed test.
1467379990 2016-07-01 Production Wells No Violations On the day of my inspection I witnessed that the production equipment included a GP Unit. Also present a stabilizer unit, 2 compressors, a vapor recovery system, a combustor and 6-400bbl tanks within containment and shared with 345059242000000 Frec Spencer A-5H. The well was equipped with a Weatherford pumping unit powered by electricity with valves in the open position. Identification was present and production records were current.
1603889048 2011-11-21 Drill / Deepen / Reopen No Violations
1667347511 2011-11-21 Drill / Deepen / Reopen No Violations Total depth was reached at 10,962. Will condition wellbore and then log well and possibly run casing later on in the week.
1920651845 2012-02-22 Completion Testing No Violations Stopped by drill site for update they were flowing well back into 500 bbl tanks and hauling water to UIC facility for proper disposal.
2059153676 2011-10-12 Drill / Deepen / Reopen No Violations Invited to attend pre-- went over over-all plan for well and how it would happen. Met many of the people I would be working with in Morgan Co.

For data sources see[7]