| Well ID: 34-019-22236
 
| Well ID: 34-019-22236
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.44090426, -81.0228252 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 40.440839447, -81.02300771 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Carroll County, Ohio|Carroll]]
+
| Country: United States
 
|-
 
|-
| Municipality:  
+
| State: Ohio
 +
|-
 +
| County: [[Carroll_County,_Ohio|Carroll]]
 +
|-
 +
| Municipality: [[Loudon_Township,_Carroll_County,_Ohio|Loudon Township]]
 
|-
 
|-
 
| Operator Name: [[CHESAPEAKE EXPLORATION LLC]]
 
| Operator Name: [[CHESAPEAKE EXPLORATION LLC]]
 
|-
 
|-
| Well Pad ID:  
+
| Well Pad ID: [[US-OH-000390]]
 
|-
 
|-
| Farm/Lease Name:  
+
| Farm/Lease Name: APPALACHIAN 16-12-5
 
|-
 
|-
| First Permit Date:  
+
| License Status: Producing
 
|-
 
|-
| Last Permit Date:  
+
| License Date: 2013-01-28
 
|-
 
|-
 
| Spud Date: 2013-02-14
 
| Spud Date: 2013-02-14
 
|-
 
|-
| Unconventional:
+
| Spud Drilling Contractor: [[NOMAC DRILLING CORP]]
|-
 
| Configuration:  
 
 
|-
 
|-
| Well Status: Producing
+
| Final Drill Date: 2013-05-27
 
|-
 
|-
| Violations: 0
+
| Well Total Depth: 12905 ft
 
|-
 
|-
| Latitude: 40.44090426
+
| Configuration: Horizontal
 
|-
 
|-
| Longitude: -81.0228252
+
| Latitude: 40.440839447
 
|-
 
|-
 +
| Longitude: -81.02300771
 
|}
 
|}
== Production Data ==
+
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" style="text-align: center"| Well Status
!scope="col" | GAS QUANTITY
+
!scope="col" style="width: 15%;text-align: center"| Well Status Date
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" style="text-align: center"| Comment
!scope="col" | CONDENSATE QUANTITY
+
|-
!scope="col" | CONDENSATE PRODUCTION DAYS
+
| APP
!scope="col" | OIL QUANTITY
+
| 2012-10-10
!scope="col" | OIL PRODUCTION DAYS
+
| Proposed Formations:TRENTON/BLACK RIVER, Issued Date:10/10/2012, Expired Date:10/10/2014 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
 
|-
 
|-
| 2013-12
+
| APP
| style="text-align:right;" | 168485.0
+
| 2012-10-17
|  
+
| Proposed Formations:POINT PLEASANT, Issued Date:10/17/2012, Expired Date:10/17/2014 12:00:00 PM, Drilling unit acres:106.31, Proposed Well Type:OG, Proposed Well Class:EDPW
|
 
|
 
| style="text-align:right;" | 6334.0
 
|
 
 
|-
 
|-
 +
| Correction to Well
 +
| 2012-10-19
 +
| CORRECTION TO GROUND LEVEL ELEVATION.
 
|-
 
|-
| 2014-1
+
| Correction to Well
| style="text-align:right;" | 223770.0
+
| 2012-11-09
| style="text-align:right;" | 86.0
+
| CORRECTION TO TARGET FOOTAGE.
|
 
|
 
| style="text-align:right;" | 5417.0
 
| style="text-align:right;" | 86.0
 
 
|-
 
|-
 +
| APP
 +
| 2013-01-28
 +
| Proposed Formations:POINT PLEASANT, Issued Date:1/28/2013, Expired Date:1/28/2015 12:00:00 PM, Drilling unit acres:357.12, Proposed Well Type:OG, Proposed Well Class:POOL
 
|-
 
|-
| 2014-2
+
| Reached Total Depth
| style="text-align:right;" | 185603.0
+
| 2013-05-27
| style="text-align:right;" | 91.0
 
 
|  
 
|  
|
 
| style="text-align:right;" | 3260.0
 
| style="text-align:right;" | 91.0
 
 
|-
 
|-
 +
| Correction to Well
 +
| 2013-09-06
 +
| CORRECTION TO TARGET INFORMATION (FOOTAGE & X, Y COORDINATES) FROM AS DRILLED SURVEY PLAT.  UNIT SIZE DECREASED TO 344.76 ACRES.
 
|-
 
|-
| 2014-3
+
| Completion Report Received
| style="text-align:right;" | 153148.0
+
| 2014-01-29
| style="text-align:right;" | 91.0
 
 
|  
 
|  
 +
|-
 +
| Construction Permit Expires
 +
| 2015-01-28
 
|  
 
|  
| style="text-align:right;" | 1482.0
 
| style="text-align:right;" | 91.0
 
|-
 
 
|-
 
|-
| 2014-4
+
| Record Last Modified
| style="text-align:right;" | 123215.0
+
| 2017-10-24
| style="text-align:right;" | 89.0
 
|
 
 
|  
 
|  
| style="text-align:right;" | 1217.0
 
| style="text-align:right;" | 89.0
 
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well and WellHistry Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Perforation Treatments ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Perforation Date
 +
!scope="col" style="text-align: center"| Interval Top (ft)
 +
!scope="col" style="text-align: center"| Interval Base (ft)
 +
!scope="col" style="text-align: center"| Number of Shots
 
|-
 
|-
| 2015-1
+
| 2014-01-29
| style="text-align:right;" | 107901.0
+
| style="text-align: right;" | 8979
| style="text-align:right;" | 90.0
+
| style="text-align: right;" | 12732
|
+
| style="text-align: right;" | 525
|
 
| style="text-align:right;" | 564.0
 
| style="text-align:right;" | 90.0
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Ohio Department of Natural Resources RBDMS
+
  | title = Risk Based Data Management System - Perfs Table
  | publisher = [http://oilandgas.ohiodnr.gov/]
+
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2015-06-19
+
  | date = 2019-05-07
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Production
+
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2015-06-20 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
[[Category:Has Chemical Data]]
+
== Fracking Activities ==
==Chemical Data==
+
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | HF Fluid Concentration
+
!scope="col" style="text-align: center"| Job Number
!scope="col" | Ingredient
+
!scope="col" style="text-align: center"| Job Start Date
!scope="col" | Additive Concentration
+
!scope="col" style="text-align: center"| Job End Date
!scope="col" | Trade Name
+
!scope="col" style="text-align: center"| True Vertical Depth (ft)
!scope="col" | Purpose
+
!scope="col" style="text-align: center"| Total Water Volume (gal)
!scope="col" | CAS number
+
!scope="col" style="text-align: center"| Total Non-Water Volume (gal)
!scope="col" | Supplier
+
|-
 +
| 1
 +
| 07/17/2013
 +
| 07/19/2013
 +
| style="text-align: right;" | 8152
 +
| style="text-align: right;" | 3,448,790.0
 +
| style="text-align: right;" | 277879
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" style="width: 100%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Trade Name
 +
!scope="col" style="text-align: center"| Supplier
 +
!scope="col" style="text-align: center"| Purpose
 +
!scope="col" style="text-align: center"| Ingredient Name
 +
!scope="col" style="white-space: nowrap;text-align: center"| CAS Number
 +
!scope="col" style="text-align: center"| Additive Percentage by Mass
 +
!scope="col" style="text-align: center"| Job Percentage by Mass
 +
!scope="col" style="text-align: center"| Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="44"| 1
 +
| rowspan="1"| Northern White Sand
 +
| rowspan="1"| PERFORMANCE TECHNOLOGIES
 +
| rowspan="1"| Proppant - Natural
 +
| Crystalline Silica (Quartz Sand, Silicon Dioxide)
 +
| 014808-60-7
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 12.9677
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| PTLSI372
 +
| rowspan="1"| PERFORMANCE TECHNOLOGIES
 +
| rowspan="1"| Scale Inhibitor
 +
| No Hazardous Components
 +
| NONE
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Recycled Produced Water
 +
| rowspan="1"| CHESAPEAKE ENERGY
 +
| rowspan="1"| Carrier/Base Fluid
 +
| Water
 +
| 007732-18-5
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 0.32548
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| PTLBW112
 +
| rowspan="1"| PERFORMANCE TECHNOLOGIES
 +
| rowspan="1"| Breaker
 +
| Ammonium Persulfate
 +
| 007727-54-0
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 0.00788
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.0497
+
|- valign="top"
| Sodium Chloride
+
| rowspan="1"| PTLGL140
| 0.0
+
| rowspan="1"| PERFORMANCE TECHNOLOGIES
| PTLAI171
+
| rowspan="1"| Gelling Agent
| PTLCS226
+
| No Hazardous Components
| 007647-14-5
+
| NONE
| PTLBW112
+
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="2"| PTLMP136
 +
| rowspan="2"| PERFORMANCE TECHNOLOGIES
 +
| rowspan="2"| Acid
 +
| Water
 +
| 007732-18-5
 +
| style="text-align: right;" | 85
 +
| style="text-align: right;" | 0.97678
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.00079
+
| Hydrochloric Acid
| 2-Ethylhexanol
+
| 007647-01-0
| 0.0
+
| style="text-align: right;" | 15
| PTLAI171
+
| style="text-align: right;" | 0.17237
| PTLCS226
+
| style="text-align: right;" | 0
| 000104-76-7
+
|-
| PTLBW112
+
|- valign="top"
 +
| rowspan="2"| EC6111A
 +
| rowspan="2"| NALCO
 +
| rowspan="2"| Anti-Bacterial Agent
 +
| Water
 +
| 007732-18-5
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.02524
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Glutaraldehyde (Pentanediol)
 +
| 000111-30-8
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.00719
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.00098
+
|- valign="top"
| Ethylene Glycol
+
| rowspan="3"| PTLCA102
| 0.0
+
| rowspan="3"| PERFORMANCE TECHNOLOGIES
| PTLAI171
+
| rowspan="3"| Cross Linker
| PTLCS226
+
| Sodium Hydroxide
| 000107-21-1
+
| 001310-73-2
| PTLBW112
+
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.0154
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Proprietary Alkyl Alcohol
 +
| TRADE SECRET
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.0154
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.0497
+
| Proprietary Inorganic Salt
| Proprietary Substituted Fatty Acid Ester
 
| 0.0
 
| PTLAI171
 
|  PTLCS226
 
 
| TRADE SECRET
 
| TRADE SECRET
| PTLBW112
+
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.0077
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="2"| PTLFR200
 +
| rowspan="2"| PERFORMANCE TECHNOLOGIES
 +
| rowspan="2"| Friction Reducer
 +
| Proprietary Aliphatic Hydrocarbon
 +
| TRADE SECRET
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.01432
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.00079
+
| Proprietary Oxyalkylated Alcohol
| Proprietary Methanol
 
| 0.0
 
| PTLAI171
 
|  PTLCS226
 
 
| TRADE SECRET
 
| TRADE SECRET
| PTLBW112
+
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00239
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| 100 Mesh Sand
 +
| rowspan="1"| PERFORMANCE TECHNOLOGIES
 +
| rowspan="1"| Proppant - Natural
 +
| Crystalline Silica (Quartz Sand, Silicon Dioxide)
 +
| 014808-60-7
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 1.53956
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.00079
+
|- valign="top"
| Diethylene Glycol
+
| rowspan="1"| PTLCS226
| 0.0
+
| rowspan="1"| PERFORMANCE TECHNOLOGIES
| PTLAI171
+
| rowspan="1"| KCl Substitute
| PTLCS226
+
| No Hazardous Components
| 000111-46-6
+
| NONE
| PTLBW112
+
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| PTLBW102
 +
| rowspan="1"| PERFORMANCE TECHNOLOGIES
 +
| rowspan="1"| Breaker
 +
| Ammonium Persulfate
 +
| 007727-54-0
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 0.00147
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| PTLIS352
 +
| rowspan="1"| PERFORMANCE TECHNOLOGIES
 +
| rowspan="1"| Iron Control Agent
 +
| Citric Acid
 +
| 000077-92-9
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 0.00059
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.0497
+
|- valign="top"
| Proprietary Aliphatic Alcohol
+
| rowspan="6"| PTLAI171
| 0.0
+
| rowspan="6"| PERFORMANCE TECHNOLOGIES
| PTLAI171
+
| rowspan="6"| Corrosion Inhibitor
| PTLCS226
+
| Proprietary Organic Amine Resin Salt
 +
| TRADE SECRET
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.00058
 +
| style="text-align: right;" | 0
 +
|-
 +
| Proprietary Aromatic Aldehyde
 
| TRADE SECRET
 
| TRADE SECRET
| PTLBW112
+
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00019
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Isopropanol (Isopropyl Alcohol, Propan-2-ol)
 +
| 000067-63-0
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.00116
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.0497
+
| Ethylene Glycol
| Tetrasodium Ethylenediaminetetraacetate
+
| 000107-21-1
| 0.0
+
| style="text-align: right;" | 30
| PTLAI171
+
| style="text-align: right;" | 0.00058
| PTLCS226
+
| style="text-align: right;" | 0
| 000064-02-8
 
| PTLBW112
 
 
|-
 
|-
 +
| Dimethyl Formamide
 +
| 000068-12-2
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00019
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.05339
+
| Proprietary Quaternary Ammonium Compound
| Proprietary Vinyl Copolymer
 
| 0.0
 
| PTLAI171
 
|  PTLCS226
 
 
| TRADE SECRET
 
| TRADE SECRET
| PTLBW112
+
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00019
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| Fresh Water
 +
| rowspan="1"| CHESAPEAKE ENERGY
 +
| rowspan="1"| Carrier/Base Fluid
 +
| Water
 +
| 007732-18-5
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 83.6688
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.00079
+
|- valign="top"
| Proprietary Alkylene Oxide Block Polymer
+
| rowspan="19"| PTLAI171, PTLBW112, PTLCS226, PTLFR200, PTLGL140, PTLSI372
| 0.0
+
| rowspan="19"| PERFORMANCE TECHNOLOGIES
| PTLAI171
+
| rowspan="19"| Breaker, Corrosion Inhibitor, Friction Reducer, Gelling Agent, KCl Substitute, Scale Inhibitor
| PTLCS226
+
| 2-Ethylhexanol
| TRADE SECRET
+
| 000104-76-7
| PTLBW112
+
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00079
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Water
 +
| 007732-18-5
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.16551
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.16575
+
| Tetrasodium Ethylenediaminetetraacetate
| Proprietary Surfactant
+
| 000064-02-8
| 0.0
+
| style="text-align: right;" | 0
| PTLAI171
+
| style="text-align: right;" | 0.0497
| PTLCS226
+
| style="text-align: right;" | 0
| TRADE SECRET
 
| PTLBW112
 
|-
 
 
|-
 
|-
| 0.16575
 
 
| Petroleum Distillate Hydrotreated Light
 
| Petroleum Distillate Hydrotreated Light
| 0.0
 
| PTLAI171
 
|  PTLCS226
 
 
| 064742-47-8
 
| 064742-47-8
| PTLBW112
+
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.16575
 +
| style="text-align: right;" | 0
 +
|-
 +
| Diethylene Glycol
 +
| 000111-46-6
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00079
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Proprietary Alkylene Oxide Block Polymer
 +
| TRADE SECRET
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00079
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.16575
 
 
| Guar Gum
 
| Guar Gum
| 0.0
 
| PTLAI171
 
|  PTLCS226
 
 
| 009000-30-0
 
| 009000-30-0
| PTLBW112
+
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.16575
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Sodium Chloride
 +
| 007647-14-5
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.0497
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.16575
+
| Proprietary Methanol
| Proprietary Clay
 
| 0.0
 
| PTLAI171
 
|  PTLCS226
 
 
| TRADE SECRET
 
| TRADE SECRET
| PTLBW112
+
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00079
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Proprietary Aliphatic Alcohol
 +
| TRADE SECRET
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.0497
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.0497
+
| Proprietary Vinyl Copolymer
| Proprietary Oxyalkylated Fatty Acid Derivative
 
| 0.0
 
| PTLAI171
 
|  PTLCS226
 
 
| TRADE SECRET
 
| TRADE SECRET
| PTLBW112
+
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.05339
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Proprietary Substituted Fatty Acid Ester
 +
| TRADE SECRET
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.0497
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.01684
+
| Proprietary Surfactant
| Proprietary Polycarboxylic Acid Polymer
 
| 0.0
 
| PTLAI171
 
|  PTLCS226
 
 
| TRADE SECRET
 
| TRADE SECRET
| PTLBW112
+
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.16575
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Proprietary Oxyalkylated Fatty Acid Derivative
 +
| TRADE SECRET
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.0497
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.16551
+
| Ethylene Glycol
| Water
+
| 000107-21-1
| 0.0
+
| style="text-align: right;" | 0
| PTLAI171
+
| style="text-align: right;" | 0.00098
| PTLCS226
+
| style="text-align: right;" | 0
| 007732-18-5
 
| PTLBW112
 
 
|-
 
|-
 +
| Proprietary Polycarboxylic Acid Polymer
 +
| TRADE SECRET
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.01684
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.0
+
| Choline Chloride
| No Hazardous Components
+
| 000067-48-1
| 0.0
+
| style="text-align: right;" | 0
| PTLSI372
+
| style="text-align: right;" | 0.09817
| Scale Inhibitor
+
| style="text-align: right;" | 0
| NONE
 
| PERFORMANCE TECHNOLOGIES
 
 
|-
 
|-
 +
| Proprietary Clay
 +
| TRADE SECRET
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.16575
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.0
+
| Copper Sulfate
| No Hazardous Components
+
| 007758-98-7
| 0.0
+
| style="text-align: right;" | 0
| PTLCS226
+
| style="text-align: right;" | 0.00056
| KCl Substitute
+
| style="text-align: right;" | 0
| NONE
 
| PERFORMANCE TECHNOLOGIES
 
|-
 
 
|-
 
|-
| 83.6688
+
|}
| Water
+
For data sources see<ref>{{cite web
| 100.0
+
| title = FracFocus Fracking Chemicals Database
| Fresh Water
+
| date = 2019-04-02
| Carrier/Base Fluid
+
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
| 007732-18-5
+
| accessdate = 2019-06-19 }}</ref>
| CHESAPEAKE ENERGY
+
== Stimulations Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Stimulation Date
 +
!scope="col" style="text-align: center"| Chemical Agent
 +
!scope="col" style="text-align: center"| Chemical Agent Concentration (%)
 +
!scope="col" style="text-align: center"| Fracking Fluid Volume
 +
!scope="col" style="text-align: center"| Mass of Proppant Used (lb)
 +
!scope="col" style="text-align: center"| Fracking Company
 +
!scope="col" style="text-align: center"| Comments
 
|-
 
|-
 +
| 2013-07-18
 +
| H2O
 +
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 5318 Bbl
 +
| style="text-align: right;" | 331520
 +
| [[Performance Technologies]]
 +
| STAGE 5
 +
35 SHOTS
 
|-
 
|-
| 0.0154
+
| 2013-07-17
| Proprietary Alkyl Alcohol
+
| H2O
| 60.0
+
| style="text-align: right;" | 15
| PTLCA102
+
| style="text-align: right;" | 5849 Bbl
| Cross Linker
+
| style="text-align: right;" | 332240
| TRADE SECRET
+
| [[Performance Technologies]]
| PERFORMANCE TECHNOLOGIES
+
| STAGE 1
|-
+
35 SHOTS
|-
 
| 0.0154
 
| Sodium Hydroxide
 
| 60.0
 
| PTLCA102
 
| Cross Linker
 
| 001310-73-2
 
| PERFORMANCE TECHNOLOGIES
 
 
|-
 
|-
 +
| 2013-07-18
 +
| H2O
 +
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 0 Bbl
 +
| style="text-align: right;" | 0
 +
| [[Performance Technologies]]
 +
| STAGE 6
 +
35 SHOTS
 
|-
 
|-
| 0.0077
+
| 2013-07-18
| Proprietary Inorganic Salt
+
| H2O
| 30.0
+
| style="text-align: right;" | 15
| PTLCA102
+
| style="text-align: right;" | 5211 Bbl
| Cross Linker
+
| style="text-align: right;" | 330420
| TRADE SECRET
+
| [[Performance Technologies]]
| PERFORMANCE TECHNOLOGIES
+
| STAGE 11
 +
35 SHOTS
 
|-
 
|-
 +
| 2013-07-18
 +
| H2O
 +
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 6086 Bbl
 +
| style="text-align: right;" | 336380
 +
| [[Performance Technologies]]
 +
| STAGE 7
 +
35 SHOTS
 
|-
 
|-
| 0.00719
+
| 2013-07-17
| Glutaraldehyde (Pentanediol)
+
| H2O
| 30.0
+
| style="text-align: right;" | 15
| EC6111A
+
| style="text-align: right;" | 5337 Bbl
| Anti-Bacterial Agent
+
| style="text-align: right;" | 331180
| 000111-30-8
+
| [[Performance Technologies]]
| NALCO
+
| STAGE 2
 +
35 SHOTS
 
|-
 
|-
 +
| 2013-07-17
 +
| H2O
 +
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 5252 Bbl
 +
| style="text-align: right;" | 329320
 +
| [[Performance Technologies]]
 +
| STAGE 3
 +
35 SHOTS
 
|-
 
|-
| 0.02524
+
| 2013-07-18
| Water
+
| H2O
| 0.0
+
| style="text-align: right;" | 15
| EC6111A
+
| style="text-align: right;" | 5693 Bbl
| Anti-Bacterial Agent
+
| style="text-align: right;" | 331400
| 007732-18-5
+
| [[Performance Technologies]]
| NALCO
+
| STAGE 10
 +
35 SHOTS
 
|-
 
|-
 +
| 2013-07-19
 +
| H2O
 +
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 5264 Bbl
 +
| style="text-align: right;" | 323200
 +
| [[Performance Technologies]]
 +
| STAGE 13
 +
35 SHOTS
 
|-
 
|-
| 0.17237
+
| 2013-07-18
| Hydrochloric Acid
+
| H2O
| 15.0
+
| style="text-align: right;" | 15
| PTLMP136
+
| style="text-align: right;" | 5239 Bbl
| Acid
+
| style="text-align: right;" | 332600
| 007647-01-0
+
| [[Performance Technologies]]
| PERFORMANCE TECHNOLOGIES
+
| STAGE 9
 +
35 SHOTS
 
|-
 
|-
 +
| 2013-07-19
 +
| H2O
 +
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 5325 Bbl
 +
| style="text-align: right;" | 335840
 +
| [[Performance Technologies]]
 +
| STAGE 12
 +
35 SHOTS
 
|-
 
|-
| 0.97678
+
| 2013-07-19
| Water
+
| H2O
| 85.0
+
| style="text-align: right;" | 15
| PTLMP136
+
| style="text-align: right;" | 5155 Bbl
| Acid
+
| style="text-align: right;" | 330180
| 007732-18-5
+
| [[Performance Technologies]]
| PERFORMANCE TECHNOLOGIES
+
| STAGE 15
 +
35 SHOTS
 
|-
 
|-
 +
| 2013-07-17
 +
| H2O
 +
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 5593 Bbl
 +
| style="text-align: right;" | 330780
 +
| [[Performance Technologies]]
 +
| STAGE 4
 +
35 SHOTS
 
|-
 
|-
| 0.00239
+
| 2013-07-18
| Proprietary Oxyalkylated Alcohol
+
| H2O
| 5.0
+
| style="text-align: right;" | 15
| PTLFR200
+
| style="text-align: right;" | 5085 Bbl
| Friction Reducer
+
| style="text-align: right;" | 330963
| TRADE SECRET
+
| [[Performance Technologies]]
| PERFORMANCE TECHNOLOGIES
+
| STAGE 8
 +
35 SHOTS
 
|-
 
|-
 +
| 2013-07-19
 +
| H2O
 +
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 5372 Bbl
 +
| style="text-align: right;" | 333180
 +
| [[Performance Technologies]]
 +
| STAGE 14
 +
35 SHOTS
 
|-
 
|-
| 0.01432
+
|}
| Proprietary Aliphatic Hydrocarbon
+
For data sources see<ref>{{cite web
| 30.0
+
| title = Risk Based Data Management System - tblStimulation Table
| PTLFR200
+
|publisher = [[Ohio Department of Natural Resources]]
| Friction Reducer
+
| date =  2019-05-07
| TRADE SECRET
+
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
| PERFORMANCE TECHNOLOGIES
+
| accessdate = 2019-05-21 }}</ref>
 +
== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Gas Quantity (mcf)
 +
!scope="col" style="text-align: center"| Oil Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 
|-
 
|-
 +
| 2013
 +
| [[CHESAPEAKE EXPLORATION LLC]]
 +
| style="text-align: right;" | 168485
 +
| style="text-align: right;" | 6334
 +
| style="text-align: right;" | 67
 
|-
 
|-
| 0.0
+
| 2014
| No Hazardous Components
+
| [[CHESAPEAKE EXPLORATION LLC]]
| 0.0
+
| style="text-align: right;" | 685736
| PTLGL140
+
| style="text-align: right;" | 11376
| Gelling Agent
+
| style="text-align: right;" | 357
| NONE
 
| PERFORMANCE TECHNOLOGIES
 
 
|-
 
|-
 +
| 2015
 +
| [[CHESAPEAKE EXPLORATION LLC]]
 +
| style="text-align: right;" | 372572
 +
| style="text-align: right;" | 3170
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 0.00019
+
| 2016
| Proprietary Quaternary Ammonium Compound
+
| [[CHESAPEAKE EXPLORATION LLC]]
| 10.0
+
| style="text-align: right;" | 265921
| PTLAI171
+
| style="text-align: right;" | 4230
| Corrosion Inhibitor
+
| style="text-align: right;" | 366
| TRADE SECRET
 
| PERFORMANCE TECHNOLOGIES
 
 
|-
 
|-
 +
| 2017
 +
| [[CHESAPEAKE EXPLORATION LLC]]
 +
| style="text-align: right;" | 214206
 +
| style="text-align: right;" | 1634
 +
| style="text-align: right;" | 360
 
|-
 
|-
| 0.00019
+
| 2018
| Dimethyl Formamide
+
| [[CHESAPEAKE EXPLORATION LLC]]
| 10.0
+
| style="text-align: right;" | 179618
| PTLAI171
+
| style="text-align: right;" | 1043
| Corrosion Inhibitor
+
| style="text-align: right;" | 365
| 000068-12-2
 
| PERFORMANCE TECHNOLOGIES
 
 
|-
 
|-
 +
| 2019
 +
| [[CHESAPEAKE EXPLORATION LLC]]
 +
| style="text-align: right;" | 38219
 +
| style="text-align: right;" | 281
 +
| style="text-align: right;" | 90
 
|-
 
|-
| 0.00058
+
|}
| Ethylene Glycol
+
For data sources see<ref>{{cite web
| 30.0
+
| title = Risk Based Data Management System - Production Table - Oil and Gas Data
| PTLAI171
+
|publisher = [[Ohio Department of Natural Resources]]
| Corrosion Inhibitor
+
| date =  2019-05-07
| 000107-21-1
+
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
| PERFORMANCE TECHNOLOGIES
+
| accessdate = 2019-05-21 }}</ref>
 +
<ref>{{cite web
 +
| title = Combined Production - Oil and Gas Data
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date = 2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Waste Data ==
 +
{| class="wikitable sortable"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Waste Type
 +
!scope="col" style="text-align: center"| Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 
|-
 
|-
 +
| 2013
 +
| [[CHESAPEAKE EXPLORATION LLC]]
 +
| Brine
 +
| style="text-align: right;" | 3043
 +
| style="text-align: right;" | 67
 
|-
 
|-
| 0.00058
+
| 2014
| Proprietary Organic Amine Resin Salt
+
| [[CHESAPEAKE EXPLORATION LLC]]
| 30.0
+
| Brine
| PTLAI171
+
| style="text-align: right;" | 1980
| Corrosion Inhibitor
+
| style="text-align: right;" | 357
| TRADE SECRET
 
| PERFORMANCE TECHNOLOGIES
 
 
|-
 
|-
 +
| 2015
 +
| [[CHESAPEAKE EXPLORATION LLC]]
 +
| Brine
 +
| style="text-align: right;" | 1254
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 0.00019
+
| 2016
| Proprietary Aromatic Aldehyde
+
| [[CHESAPEAKE EXPLORATION LLC]]
| 10.0
+
| Brine
| PTLAI171
+
| style="text-align: right;" | 1492
| Corrosion Inhibitor
+
| style="text-align: right;" | 366
| TRADE SECRET
 
| PERFORMANCE TECHNOLOGIES
 
 
|-
 
|-
 +
| 2017
 +
| [[CHESAPEAKE EXPLORATION LLC]]
 +
| Brine
 +
| style="text-align: right;" | 1830
 +
| style="text-align: right;" | 360
 
|-
 
|-
| 60.0
+
| 2018
| Isopropanol (Isopropyl Alcohol
+
| [[CHESAPEAKE EXPLORATION LLC]]
| 67.0
+
| Brine
| PTLAI171
+
| style="text-align: right;" | 2210
| Corrosion Inhibitor
+
| style="text-align: right;" | 365
| Propan-2-ol)
 
| PERFORMANCE TECHNOLOGIES
 
 
|-
 
|-
 +
| 2019
 +
| [[CHESAPEAKE EXPLORATION LLC]]
 +
| Brine
 +
| style="text-align: right;" | 207
 +
| style="text-align: right;" | 90
 
|-
 
|-
| 0.00147
+
|}
| Ammonium Persulfate
+
For data sources see<ref>{{cite web
| 100.0
+
| title = Risk Based Data Management System - Production Table - Brine Data
| PTLBW102
+
|publisher = [[Ohio Department of Natural Resources]]
| Breaker
+
| date =  2019-05-07
| 007727-54-0
+
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
| PERFORMANCE TECHNOLOGIES
+
| accessdate = 2019-05-21 }}</ref>
 +
<ref>{{cite web
 +
| title = Combined Production - Brine Data
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date = 2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Inspection Date
 +
!scope="col" style="text-align: center"| Inspection Type
 +
!scope="col" style="text-align: center"| Inspection Result
 +
!scope="col" style="text-align: center"| Inspection Comments
 
|-
 
|-
 +
| 1225120654
 +
| 2017-10-16
 +
| Production Wells
 +
| No Violations
 +
| The well is in production.  No changes have been made to the well or production equipment since my last inspection.  The pad consists of six production wells.  No violations were noted at the time of inspection.
 
|-
 
|-
| 0.32548
+
| 1456336326
| Water
+
| 2016-02-18
| 100.0
+
| Preliminary Restoration
| Recycled Produced Water
+
| No Violations
| Carrier/Base Fluid
+
| I was on location to conduct a preliminary restoration inspection.  The #1H well is in production.  The well is open flow with a wellhead Christmas tree assembly.  Jersey barriers were installed around the wellhead.  The well is properly identified with a clear, legibly-marked well identification sign.  The tank battery consisted of eight, 400 BBL production tanks and was diked. The tanks are located within a spray-lined and sealed secondary containment.  There are e-stops outside the barriers, and the tanks are grounded, and have static dissipaters.  There is a truck grounding area for trucks collecting condensate and/or produced water.  Lightning protection and a windsock are installed on top of the production tanks.  Other production equipment on the well pad consisted of:
| 007732-18-5
+
8 Storage tanks
| CHESAPEAKE ENERGY
+
6 Producing wells
 +
6 Sand separators
 +
6 Gas processing Units
 +
1 Vapor Recovery Unit
 +
The entire well pad is enclosed with a six-foot high, chain link fence with three-strand barbed wire and the man doors were locked.  Along the interior of the chain link fence there is an earthen berm and it was stable. The soil stockpile is well-stabilized with vegetation.  Drainage and erosion controls at the pad are in place and functioning.  A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure.  The pad has a crushed limestone surface and is in good repair.  The access gate to the lease road was not locked.  The lease road is stable and drivable.
 
|-
 
|-
 +
| 1539543520
 +
| 2015-12-23
 +
| Preliminary Restoration
 +
| No Violations
 +
| I was on location to conduct a preliminary restoration inspection.  The well is equipped with a plunger lift unit.  Jersey barriers were installed around the wellhead.  The well is properly identified with a clear, legibly-marked well identification sign.  The tank battery consisted of eight, 400 BBL production tanks and was diked. The tanks are located within a spray-lined and sealed secondary containment.  There are e-stops outside the barriers, and the tanks are grounded, and have static dissipators.  There is a truck grounding area for trucks collecting condensate and/or produced water.  Lightning protection and a windsock are installed on top of the production tanks.  Other production equipment on the well pad consisted of:
 +
 +
 +
 +
 +
Jersey barriers are installed around the production equipment.  The entire well pad is enclosed with a six-foot high, chain link fence with three-strand barbed wire and the man doors were locked.  Along the interior of the chain link fence there is an earthen berm and it was stable. The soil stockpile is well-stabilized with vegetation.  Drainage and erosion controls at the pad are in place and functioning.  A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure.  The pad has a crushed limestone surface, and is in good repair.  The lease road is stable and drivable.  Preliminary restoration passed.
 
|-
 
|-
| 0.00788
+
| 1958002567
| Ammonium Persulfate
+
| 2017-10-16
| 100.0
+
| Production Wells
| PTLBW112
+
| No Violations
| Breaker
+
| The well is in production and is equipped with a plunger-lift assembly.  No changes have been made to the pad since my last inspection.  The 13.375 anular pressure gauge displayed a reading of zero psi.  No violations were observed at the time of inspection.
| 007727-54-0
 
| PERFORMANCE TECHNOLOGIES
 
 
|-
 
|-
 
|}
 
|}
For data sources see<ref>{{cite web | title = FracFocus Chemical Disclosure Registry |publisher = [http://www.fracfocusdata.org/DisclosureSearch/]| date = 2015-08-10 | url = http://wellwiki.org/wiki/Well_Chemicals_Data_Sources | accessdate = 2015-08-10 }}</ref>
+
<!--==== Violations Commited ====
== References ==
+
{| class="wikitable sortable" width="95%"
{{reflist}}
+
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Violation ID
 +
!scope="col" style="text-align: center"| Violation Date
 +
!scope="col" style="text-align: center"| Violation Code
 +
!scope="col" style="text-align: center"| Violation Comments
 +
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date = 2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
==References==
 +
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Ohio Wells]]
 +
[[Category:FracFocus]]

Revision as of 07:54, 31 July 2019

Well Details

Well ID: 34-019-22236
Loading map...
Country: United States
State: Ohio
County: Carroll
Municipality: Loudon Township
Operator Name: CHESAPEAKE EXPLORATION LLC
Well Pad ID: US-OH-000390
Farm/Lease Name: APPALACHIAN 16-12-5
License Status: Producing
License Date: 2013-01-28
Spud Date: 2013-02-14
Spud Drilling Contractor: NOMAC DRILLING CORP
Final Drill Date: 2013-05-27
Well Total Depth: 12905 ft
Configuration: Horizontal
Latitude: 40.440839447
Longitude: -81.02300771

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-10-10 Proposed Formations:TRENTON/BLACK RIVER, Issued Date:10/10/2012, Expired Date:10/10/2014 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2012-10-17 Proposed Formations:POINT PLEASANT, Issued Date:10/17/2012, Expired Date:10/17/2014 12:00:00 PM, Drilling unit acres:106.31, Proposed Well Type:OG, Proposed Well Class:EDPW
Correction to Well 2012-10-19 CORRECTION TO GROUND LEVEL ELEVATION.
Correction to Well 2012-11-09 CORRECTION TO TARGET FOOTAGE.
APP 2013-01-28 Proposed Formations:POINT PLEASANT, Issued Date:1/28/2013, Expired Date:1/28/2015 12:00:00 PM, Drilling unit acres:357.12, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2013-05-27
Correction to Well 2013-09-06 CORRECTION TO TARGET INFORMATION (FOOTAGE & X, Y COORDINATES) FROM AS DRILLED SURVEY PLAT. UNIT SIZE DECREASED TO 344.76 ACRES.
Completion Report Received 2014-01-29
Construction Permit Expires 2015-01-28
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-01-29 8979 12732 525

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 07/17/2013 07/19/2013 8152 3,448,790.0 277879

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Northern White Sand PERFORMANCE TECHNOLOGIES Proppant - Natural Crystalline Silica (Quartz Sand, Silicon Dioxide) 014808-60-7 100 12.9677 0
PTLSI372 PERFORMANCE TECHNOLOGIES Scale Inhibitor No Hazardous Components NONE 0 0 0
Recycled Produced Water CHESAPEAKE ENERGY Carrier/Base Fluid Water 007732-18-5 100 0.32548 0
PTLBW112 PERFORMANCE TECHNOLOGIES Breaker Ammonium Persulfate 007727-54-0 100 0.00788 0
PTLGL140 PERFORMANCE TECHNOLOGIES Gelling Agent No Hazardous Components NONE 0 0 0
PTLMP136 PERFORMANCE TECHNOLOGIES Acid Water 007732-18-5 85 0.97678 0
Hydrochloric Acid 007647-01-0 15 0.17237 0
EC6111A NALCO Anti-Bacterial Agent Water 007732-18-5 0 0.02524 0
Glutaraldehyde (Pentanediol) 000111-30-8 30 0.00719 0
PTLCA102 PERFORMANCE TECHNOLOGIES Cross Linker Sodium Hydroxide 001310-73-2 60 0.0154 0
Proprietary Alkyl Alcohol TRADE SECRET 60 0.0154 0
Proprietary Inorganic Salt TRADE SECRET 30 0.0077 0
PTLFR200 PERFORMANCE TECHNOLOGIES Friction Reducer Proprietary Aliphatic Hydrocarbon TRADE SECRET 30 0.01432 0
Proprietary Oxyalkylated Alcohol TRADE SECRET 5 0.00239 0
100 Mesh Sand PERFORMANCE TECHNOLOGIES Proppant - Natural Crystalline Silica (Quartz Sand, Silicon Dioxide) 014808-60-7 100 1.53956 0
PTLCS226 PERFORMANCE TECHNOLOGIES KCl Substitute No Hazardous Components NONE 0 0 0
PTLBW102 PERFORMANCE TECHNOLOGIES Breaker Ammonium Persulfate 007727-54-0 100 0.00147 0
PTLIS352 PERFORMANCE TECHNOLOGIES Iron Control Agent Citric Acid 000077-92-9 100 0.00059 0
PTLAI171 PERFORMANCE TECHNOLOGIES Corrosion Inhibitor Proprietary Organic Amine Resin Salt TRADE SECRET 30 0.00058 0
Proprietary Aromatic Aldehyde TRADE SECRET 10 0.00019 0
Isopropanol (Isopropyl Alcohol, Propan-2-ol) 000067-63-0 60 0.00116 0
Ethylene Glycol 000107-21-1 30 0.00058 0
Dimethyl Formamide 000068-12-2 10 0.00019 0
Proprietary Quaternary Ammonium Compound TRADE SECRET 10 0.00019 0
Fresh Water CHESAPEAKE ENERGY Carrier/Base Fluid Water 007732-18-5 100 83.6688 0
PTLAI171, PTLBW112, PTLCS226, PTLFR200, PTLGL140, PTLSI372 PERFORMANCE TECHNOLOGIES Breaker, Corrosion Inhibitor, Friction Reducer, Gelling Agent, KCl Substitute, Scale Inhibitor 2-Ethylhexanol 000104-76-7 0 0.00079 0
Water 007732-18-5 0 0.16551 0
Tetrasodium Ethylenediaminetetraacetate 000064-02-8 0 0.0497 0
Petroleum Distillate Hydrotreated Light 064742-47-8 0 0.16575 0
Diethylene Glycol 000111-46-6 0 0.00079 0
Proprietary Alkylene Oxide Block Polymer TRADE SECRET 0 0.00079 0
Guar Gum 009000-30-0 0 0.16575 0
Sodium Chloride 007647-14-5 0 0.0497 0
Proprietary Methanol TRADE SECRET 0 0.00079 0
Proprietary Aliphatic Alcohol TRADE SECRET 0 0.0497 0
Proprietary Vinyl Copolymer TRADE SECRET 0 0.05339 0
Proprietary Substituted Fatty Acid Ester TRADE SECRET 0 0.0497 0
Proprietary Surfactant TRADE SECRET 0 0.16575 0
Proprietary Oxyalkylated Fatty Acid Derivative TRADE SECRET 0 0.0497 0
Ethylene Glycol 000107-21-1 0 0.00098 0
Proprietary Polycarboxylic Acid Polymer TRADE SECRET 0 0.01684 0
Choline Chloride 000067-48-1 0 0.09817 0
Proprietary Clay TRADE SECRET 0 0.16575 0
Copper Sulfate 007758-98-7 0 0.00056 0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2013-07-18 H2O 15 5318 Bbl 331520 Performance Technologies STAGE 5

35 SHOTS

2013-07-17 H2O 15 5849 Bbl 332240 Performance Technologies STAGE 1

35 SHOTS

2013-07-18 H2O 15 0 Bbl 0 Performance Technologies STAGE 6

35 SHOTS

2013-07-18 H2O 15 5211 Bbl 330420 Performance Technologies STAGE 11

35 SHOTS

2013-07-18 H2O 15 6086 Bbl 336380 Performance Technologies STAGE 7

35 SHOTS

2013-07-17 H2O 15 5337 Bbl 331180 Performance Technologies STAGE 2

35 SHOTS

2013-07-17 H2O 15 5252 Bbl 329320 Performance Technologies STAGE 3

35 SHOTS

2013-07-18 H2O 15 5693 Bbl 331400 Performance Technologies STAGE 10

35 SHOTS

2013-07-19 H2O 15 5264 Bbl 323200 Performance Technologies STAGE 13

35 SHOTS

2013-07-18 H2O 15 5239 Bbl 332600 Performance Technologies STAGE 9

35 SHOTS

2013-07-19 H2O 15 5325 Bbl 335840 Performance Technologies STAGE 12

35 SHOTS

2013-07-19 H2O 15 5155 Bbl 330180 Performance Technologies STAGE 15

35 SHOTS

2013-07-17 H2O 15 5593 Bbl 330780 Performance Technologies STAGE 4

35 SHOTS

2013-07-18 H2O 15 5085 Bbl 330963 Performance Technologies STAGE 8

35 SHOTS

2013-07-19 H2O 15 5372 Bbl 333180 Performance Technologies STAGE 14

35 SHOTS

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2013 CHESAPEAKE EXPLORATION LLC 168485 6334 67
2014 CHESAPEAKE EXPLORATION LLC 685736 11376 357
2015 CHESAPEAKE EXPLORATION LLC 372572 3170 365
2016 CHESAPEAKE EXPLORATION LLC 265921 4230 366
2017 CHESAPEAKE EXPLORATION LLC 214206 1634 360
2018 CHESAPEAKE EXPLORATION LLC 179618 1043 365
2019 CHESAPEAKE EXPLORATION LLC 38219 281 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2013 CHESAPEAKE EXPLORATION LLC Brine 3043 67
2014 CHESAPEAKE EXPLORATION LLC Brine 1980 357
2015 CHESAPEAKE EXPLORATION LLC Brine 1254 365
2016 CHESAPEAKE EXPLORATION LLC Brine 1492 366
2017 CHESAPEAKE EXPLORATION LLC Brine 1830 360
2018 CHESAPEAKE EXPLORATION LLC Brine 2210 365
2019 CHESAPEAKE EXPLORATION LLC Brine 207 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1225120654 2017-10-16 Production Wells No Violations The well is in production. No changes have been made to the well or production equipment since my last inspection. The pad consists of six production wells. No violations were noted at the time of inspection.
1456336326 2016-02-18 Preliminary Restoration No Violations I was on location to conduct a preliminary restoration inspection. The #1H well is in production. The well is open flow with a wellhead Christmas tree assembly. Jersey barriers were installed around the wellhead. The well is properly identified with a clear, legibly-marked well identification sign. The tank battery consisted of eight, 400 BBL production tanks and was diked. The tanks are located within a spray-lined and sealed secondary containment. There are e-stops outside the barriers, and the tanks are grounded, and have static dissipaters. There is a truck grounding area for trucks collecting condensate and/or produced water. Lightning protection and a windsock are installed on top of the production tanks. Other production equipment on the well pad consisted of:

8 Storage tanks 6 Producing wells 6 Sand separators 6 Gas processing Units 1 Vapor Recovery Unit The entire well pad is enclosed with a six-foot high, chain link fence with three-strand barbed wire and the man doors were locked. Along the interior of the chain link fence there is an earthen berm and it was stable. The soil stockpile is well-stabilized with vegetation. Drainage and erosion controls at the pad are in place and functioning. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. The pad has a crushed limestone surface and is in good repair. The access gate to the lease road was not locked. The lease road is stable and drivable.

1539543520 2015-12-23 Preliminary Restoration No Violations I was on location to conduct a preliminary restoration inspection. The well is equipped with a plunger lift unit. Jersey barriers were installed around the wellhead. The well is properly identified with a clear, legibly-marked well identification sign. The tank battery consisted of eight, 400 BBL production tanks and was diked. The tanks are located within a spray-lined and sealed secondary containment. There are e-stops outside the barriers, and the tanks are grounded, and have static dissipators. There is a truck grounding area for trucks collecting condensate and/or produced water. Lightning protection and a windsock are installed on top of the production tanks. Other production equipment on the well pad consisted of:



Jersey barriers are installed around the production equipment. The entire well pad is enclosed with a six-foot high, chain link fence with three-strand barbed wire and the man doors were locked. Along the interior of the chain link fence there is an earthen berm and it was stable. The soil stockpile is well-stabilized with vegetation. Drainage and erosion controls at the pad are in place and functioning. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. The pad has a crushed limestone surface, and is in good repair. The lease road is stable and drivable. Preliminary restoration passed.

1958002567 2017-10-16 Production Wells No Violations The well is in production and is equipped with a plunger-lift assembly. No changes have been made to the pad since my last inspection. The 13.375 anular pressure gauge displayed a reading of zero psi. No violations were observed at the time of inspection.