| Well ID: 37-081-20384
 
| Well ID: 37-081-20384
| style="height=100%; align=center" rowspan="14" | {{#display_map: 41.270236, -76.607769 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.270236, -76.607769 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 21: Line 21:
 
| License Status: Active
 
| License Status: Active
 
|-
 
|-
| Spud Date: 08/01/2011
+
| Spud Date: 2011-08-01
 
|-
 
|-
| Permit Date: 10/15/2010
+
| Permit Date: 2010-10-15
 
|-
 
|-
 
| Unconventional Well: Y
 
| Unconventional Well: Y
Line 49: Line 49:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2012-10-17
 +
| 2012-10-17
 +
| style="text-align: right;" | 7049.00
 +
| style="text-align: right;" | 3,340,342.0
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="37"| 1
 +
| rowspan="1"| DWP-612
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Friction Reducer
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| DAP-901
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Scale Inhibitor
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Sand (Proppant)
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Propping Agent
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="30"| Hydrochloric Acid
 +
| rowspan="30"| Calfrac Well Services
 +
| rowspan="30"| Clean Perforations
 +
| Olefin
 +
|
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00007000
 +
| style="text-align: right;" |
 +
|-
 +
| Polyacrylamide polymer
 +
|
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.03
 +
| style="text-align: right;" |
 +
|-
 +
| Ilmenite (FeTiO3), conc.
 +
| 98072-94-7
 +
| style="text-align: right;" | 0.10
 +
| style="text-align: right;" | 0.00131000
 +
| style="text-align: right;" |
 +
|-
 +
| Distillates, petroleum, hydrotreated light
 +
| 64742-47-8
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.02
 +
| style="text-align: right;" |
 +
|-
 +
| Acetic acid
 +
| 64-19-7
 +
| style="text-align: right;" | 1.00
 +
| style="text-align: right;" | 0.00018000
 +
| style="text-align: right;" |
 +
|-
 +
| Apatite
 +
| 64476-38-6
 +
| style="text-align: right;" | 0.10
 +
| style="text-align: right;" | 0.00281000
 +
| style="text-align: right;" |
 +
|-
 +
| Illite
 +
| 12173-60-3
 +
| style="text-align: right;" | 1.00
 +
| style="text-align: right;" | 0.00355000
 +
| style="text-align: right;" |
 +
|-
 +
| Thiourea polymer
 +
| 68527-49-1
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00045000
 +
| style="text-align: right;" |
 +
|-
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Ammonium chloride
 +
| 12125-02-9
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00111000
 +
| style="text-align: right;" |
 +
|-
 +
| Organic phosphonate 1
 +
|
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00553000
 +
| style="text-align: right;" |
 +
|-
 +
| Organic phosphonate 2
 +
|
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00184000
 +
| style="text-align: right;" |
 +
|-
 +
| Polyoxyalkylenes surfactant
 +
|
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00460000
 +
| style="text-align: right;" |
 +
|-
 +
| Goethite
 +
| 1310-14-1
 +
| style="text-align: right;" | 0.10
 +
| style="text-align: right;" | 0.00580000
 +
| style="text-align: right;" |
 +
|-
 +
| Oxyalkylated polyamine
 +
|
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00092000
 +
| style="text-align: right;" |
 +
|-
 +
| Amine salt
 +
|
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00092000
 +
| style="text-align: right;" |
 +
|-
 +
| Polyoxyalkylenes
 +
|
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00045000
 +
| style="text-align: right;" |
 +
|-
 +
| Polyethylene glycol
 +
| 25322-68-3
 +
| style="text-align: right;" | 70.00
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 +
|-
 +
| 2,2-Dibromo-3-nitrilopropionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 +
|-
 +
| Biotite
 +
| 1302-27-8
 +
| style="text-align: right;" | 0.10
 +
| style="text-align: right;" | 0.00281000
 +
| style="text-align: right;" |
 +
|-
 +
| Fatty acids
 +
|
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00045000
 +
| style="text-align: right;" |
 +
|-
 +
| Sodium chloride
 +
| 7647-14-5
 +
| style="text-align: right;" | 1.00
 +
| style="text-align: right;" | 0.00001000
 +
| style="text-align: right;" |
 +
|-
 +
| Methanol
 +
| 67-56-1
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.00642000
 +
| style="text-align: right;" |
 +
|-
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 37.00
 +
| style="text-align: right;" | 0.31
 +
| style="text-align: right;" |
 +
|-
 +
| Propargyl Alcohol
 +
|
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00015000
 +
| style="text-align: right;" |
 +
|-
 +
| Carbonic acid calcium salt (1:1)
 +
| 471-34-1
 +
| style="text-align: right;" | 1.00
 +
| style="text-align: right;" | 0.03
 +
| style="text-align: right;" |
 +
|-
 +
| Citric acid
 +
| 77-92-9
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.00315000
 +
| style="text-align: right;" |
 +
|-
 +
| Quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 16.21
 +
| style="text-align: right;" |
 +
|-
 +
| Formalin
 +
| 50-00-0
 +
| style="text-align: right;" | 0.10
 +
| style="text-align: right;" | 0.00003000
 +
| style="text-align: right;" |
 +
|-
 +
| Nonionic surfactant
 +
|
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00460000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Water
 +
| rowspan="1"|
 +
| rowspan="1"| BaseFluid/Mix Water
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 83.35
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| DAP-925
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Acid Corrosion Inhibitor
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| DAP-103
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Iron Control
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| DWP-944
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Biocide
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 334: Line 625:
 
| 2021414
 
| 2021414
 
| Primary Facility
 
| Primary Facility
| 11/21/2011
+
| 2011-11-21
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 341: Line 632:
 
| 2031005
 
| 2031005
 
| Primary Facility
 
| Primary Facility
| 01/03/2012
+
| 2012-01-03
 
| Follow-up Inspection
 
| Follow-up Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 348: Line 639:
 
| 2067483
 
| 2067483
 
| Primary Facility
 
| Primary Facility
| 05/11/2012
+
| 2012-05-11
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 355: Line 646:
 
| 2076763
 
| 2076763
 
| Primary Facility
 
| Primary Facility
| 06/12/2012
+
| 2012-06-12
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 362: Line 653:
 
| 2094167
 
| 2094167
 
| Primary Facility
 
| Primary Facility
| 08/23/2012
+
| 2012-08-23
 
| Routine/Partial Inspection
 
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 369: Line 660:
 
| 2117175
 
| 2117175
 
| Primary Facility
 
| Primary Facility
| 11/20/2012
+
| 2012-11-20
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 376: Line 667:
 
| 2123235
 
| 2123235
 
| Primary Facility
 
| Primary Facility
| 12/06/2012
+
| 2012-12-06
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 383: Line 674:
 
| 2132687
 
| 2132687
 
| Primary Facility
 
| Primary Facility
| 01/22/2013
+
| 2013-01-22
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 425: Line 716:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
== Fracking Activities ==
 
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Job Start Date
 
!scope="col" | Job End Date
 
!scope="col" | True Vertical Depth (ft)
 
!scope="col" | Total Water Volume (gal)
 
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
| 1
 
| 10/17/2012
 
| 10/17/2012
 
| style="text-align: right;" | 7049.00
 
| style="text-align: right;" | 3,340,342.0
 
| style="text-align: right;" |
 
|-
 
|}
 
==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Trade Name
 
!scope="col" | Supplier
 
!scope="col" | Purpose
 
!scope="col" | Ingredient Name
 
!scope="col" | CAS Number
 
!scope="col" | Additive Percentage by Mass
 
!scope="col" | Job Percentage by Mass
 
!scope="col" | Mass Used (lb)
 
|-
 
|- valign="top"
 
| rowspan="37"| 1
 
| rowspan="1"| DWP-612
 
| rowspan="1"| Calfrac Well Services
 
| rowspan="1"| Friction Reducer
 
|
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| DAP-901
 
| rowspan="1"| Calfrac Well Services
 
| rowspan="1"| Scale Inhibitor
 
|
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Sand (Proppant)
 
| rowspan="1"| Calfrac Well Services
 
| rowspan="1"| Propping Agent
 
|
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="30"| Hydrochloric Acid
 
| rowspan="30"| Calfrac Well Services
 
| rowspan="30"| Clean Perforations
 
| Olefin
 
|
 
| style="text-align: right;" | 5.00
 
| style="text-align: right;" | 0.00007000
 
| style="text-align: right;" |
 
|-
 
| Polyacrylamide polymer
 
|
 
| style="text-align: right;" | 40.00
 
| style="text-align: right;" | 0.03
 
| style="text-align: right;" |
 
|-
 
| Ilmenite (FeTiO3), conc.
 
| 98072-94-7
 
| style="text-align: right;" | 0.10
 
| style="text-align: right;" | 0.00131000
 
| style="text-align: right;" |
 
|-
 
| Distillates, petroleum, hydrotreated light
 
| 64742-47-8
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.02
 
| style="text-align: right;" |
 
|-
 
| Acetic acid
 
| 64-19-7
 
| style="text-align: right;" | 1.00
 
| style="text-align: right;" | 0.00018000
 
| style="text-align: right;" |
 
|-
 
| Apatite
 
| 64476-38-6
 
| style="text-align: right;" | 0.10
 
| style="text-align: right;" | 0.00281000
 
| style="text-align: right;" |
 
|-
 
| Illite
 
| 12173-60-3
 
| style="text-align: right;" | 1.00
 
| style="text-align: right;" | 0.00355000
 
| style="text-align: right;" |
 
|-
 
| Thiourea polymer
 
| 68527-49-1
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.00045000
 
| style="text-align: right;" |
 
|-
 
|
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
| Ammonium chloride
 
| 12125-02-9
 
| style="text-align: right;" | 10.00
 
| style="text-align: right;" | 0.00111000
 
| style="text-align: right;" |
 
|-
 
| Organic phosphonate 1
 
|
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.00553000
 
| style="text-align: right;" |
 
|-
 
| Organic phosphonate 2
 
|
 
| style="text-align: right;" | 10.00
 
| style="text-align: right;" | 0.00184000
 
| style="text-align: right;" |
 
|-
 
| Polyoxyalkylenes surfactant
 
|
 
| style="text-align: right;" | 5.00
 
| style="text-align: right;" | 0.00460000
 
| style="text-align: right;" |
 
|-
 
| Goethite
 
| 1310-14-1
 
| style="text-align: right;" | 0.10
 
| style="text-align: right;" | 0.00580000
 
| style="text-align: right;" |
 
|-
 
| Oxyalkylated polyamine
 
|
 
| style="text-align: right;" | 5.00
 
| style="text-align: right;" | 0.00092000
 
| style="text-align: right;" |
 
|-
 
| Amine salt
 
|
 
| style="text-align: right;" | 5.00
 
| style="text-align: right;" | 0.00092000
 
| style="text-align: right;" |
 
|-
 
| Polyoxyalkylenes
 
|
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.00045000
 
| style="text-align: right;" |
 
|-
 
| Polyethylene glycol
 
| 25322-68-3
 
| style="text-align: right;" | 70.00
 
| style="text-align: right;" | 0.01
 
| style="text-align: right;" |
 
|-
 
| 2,2-Dibromo-3-nitrilopropionamide
 
| 10222-01-2
 
| style="text-align: right;" | 40.00
 
| style="text-align: right;" | 0.01
 
| style="text-align: right;" |
 
|-
 
| Biotite
 
| 1302-27-8
 
| style="text-align: right;" | 0.10
 
| style="text-align: right;" | 0.00281000
 
| style="text-align: right;" |
 
|-
 
| Fatty acids
 
|
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.00045000
 
| style="text-align: right;" |
 
|-
 
| Sodium chloride
 
| 7647-14-5
 
| style="text-align: right;" | 1.00
 
| style="text-align: right;" | 0.00001000
 
| style="text-align: right;" |
 
|-
 
| Methanol
 
| 67-56-1
 
| style="text-align: right;" | 60.00
 
| style="text-align: right;" | 0.00642000
 
| style="text-align: right;" |
 
|-
 
| Hydrochloric acid
 
| 7647-01-0
 
| style="text-align: right;" | 37.00
 
| style="text-align: right;" | 0.31
 
| style="text-align: right;" |
 
|-
 
| Propargyl Alcohol
 
|
 
| style="text-align: right;" | 10.00
 
| style="text-align: right;" | 0.00015000
 
| style="text-align: right;" |
 
|-
 
| Carbonic acid calcium salt (1:1)
 
| 471-34-1
 
| style="text-align: right;" | 1.00
 
| style="text-align: right;" | 0.03
 
| style="text-align: right;" |
 
|-
 
| Citric acid
 
| 77-92-9
 
| style="text-align: right;" | 60.00
 
| style="text-align: right;" | 0.00315000
 
| style="text-align: right;" |
 
|-
 
| Quartz
 
| 14808-60-7
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 16.21
 
| style="text-align: right;" |
 
|-
 
| Formalin
 
| 50-00-0
 
| style="text-align: right;" | 0.10
 
| style="text-align: right;" | 0.00003000
 
| style="text-align: right;" |
 
|-
 
| Nonionic surfactant
 
|
 
| style="text-align: right;" | 5.00
 
| style="text-align: right;" | 0.00460000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Water
 
| rowspan="1"|
 
| rowspan="1"| BaseFluid/Mix Water
 
| Water
 
| 7732-18-5
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 83.35
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| DAP-925
 
| rowspan="1"| Calfrac Well Services
 
| rowspan="1"| Acid Corrosion Inhibitor
 
|
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| DAP-103
 
| rowspan="1"| Calfrac Well Services
 
| rowspan="1"| Iron Control
 
|
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| DWP-944
 
| rowspan="1"| Calfrac Well Services
 
| rowspan="1"| Biocide
 
|
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
|}
 
For data sources see<ref>{{cite web
 
| title =FracFocus Fracking Chemicals Database
 
| date = 2019-04-02
 
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
| accessdate = 2019-06-19 }}</ref>
 
 
==References==
 
==References==
 
<references/>
 
<references/>

Revision as of 22:30, 1 August 2019

Well Details

Well ID: 37-081-20384
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Penn Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 149524
Farm/Lease Name: WARBURTON UNIT 4H
License Status: Active
Spud Date: 2011-08-01
Permit Date: 2010-10-15
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.270236
Longitude: -76.607769

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-10-17 2012-10-17 7049.00 3,340,342.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 DWP-612 Calfrac Well Services Friction Reducer
DAP-901 Calfrac Well Services Scale Inhibitor
Sand (Proppant) Calfrac Well Services Propping Agent
Hydrochloric Acid Calfrac Well Services Clean Perforations Olefin 5.00 0.00007000
Polyacrylamide polymer 40.00 0.03
Ilmenite (FeTiO3), conc. 98072-94-7 0.10 0.00131000
Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
Acetic acid 64-19-7 1.00 0.00018000
Apatite 64476-38-6 0.10 0.00281000
Illite 12173-60-3 1.00 0.00355000
Thiourea polymer 68527-49-1 30.00 0.00045000
Ammonium chloride 12125-02-9 10.00 0.00111000
Organic phosphonate 1 30.00 0.00553000
Organic phosphonate 2 10.00 0.00184000
Polyoxyalkylenes surfactant 5.00 0.00460000
Goethite 1310-14-1 0.10 0.00580000
Oxyalkylated polyamine 5.00 0.00092000
Amine salt 5.00 0.00092000
Polyoxyalkylenes 30.00 0.00045000
Polyethylene glycol 25322-68-3 70.00 0.01
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 40.00 0.01
Biotite 1302-27-8 0.10 0.00281000
Fatty acids 30.00 0.00045000
Sodium chloride 7647-14-5 1.00 0.00001000
Methanol 67-56-1 60.00 0.00642000
Hydrochloric acid 7647-01-0 37.00 0.31
Propargyl Alcohol 10.00 0.00015000
Carbonic acid calcium salt (1:1) 471-34-1 1.00 0.03
Citric acid 77-92-9 60.00 0.00315000
Quartz 14808-60-7 100.00 16.21
Formalin 50-00-0 0.10 0.00003000
Nonionic surfactant 5.00 0.00460000
Water BaseFluid/Mix Water Water 7732-18-5 100.00 83.35
DAP-925 Calfrac Well Services Acid Corrosion Inhibitor
DAP-103 Calfrac Well Services Iron Control
DWP-944 Calfrac Well Services Biocide

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 595,775.00 312 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 721,567.00 357 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 757,770.00 347 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 369,069.00 278 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 403,730.00 339 0.00 0 0.00 0
2018 EXCO RESOURCES PA LLC 346,336.00 333 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 84,631.00 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2011-S02 Drilling Fluid Waste (in Barrels) 250.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE EPA ID: 748-163
2011-S02 Drilling Fluid Waste (in Barrels) 350.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012-S01 Drill Cuttings (in Tons) 302.28 Tons LANDFILL 301358
2012-S01 Drilling Fluid Waste (in Barrels) 100.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012-S02 Fracing Fluid Waste (in Barrels) 2,653.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S01 Fracturing Fluid Waste (in Tons) 19.83 Tons LANDFILL 301358
2013-S01 Produced Fluid (in Barrels) 1,709.94 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013-S02 Produced Fluid (in Barrels) 492.32 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC024
2013-S02 Produced Fluid (in Barrels) 861.84 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013-S02 Produced Fluid (in Barrels) 616.65 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC009
2013-S02 Produced Fluid (in Barrels) 54.75 Bbl STORAGE PENDING DISPOSAL OR REUSE
2014-S01 Produced Fluid (in Barrels) 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014-S01 Produced Fluid (in Barrels) 126.20 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014-S01 Produced Fluid (in Barrels) 47.60 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC024
2014-S02 Produced Fluid (in Barrels) 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S01 Produced Fluid (in Barrels) 109.50 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2015-S02 Produced Fluid (in Barrels) 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC009
2016-S02 Produced Fluid (in Barrels) RWC 802 220.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-M04 Produced Fluid (in Barrels) RWC 802 50.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017-M07 Produced Fluid (in Barrels) RWC 802 50.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2018-M11 Produced Fluid (in Barrels) RWC 802 100.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2018-M12 Produced Fluid (in Barrels) RWC 802 155.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2019-M01 Produced Fluid (in Barrels) RWC 802 15.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2019-M02 Produced Fluid (in Barrels) RWC 802 30.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2019-M03 Produced Fluid (in Barrels) RWC 802 39.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2021414 Primary Facility 2011-11-21 Drilling/Alteration No Violations Noted
2031005 Primary Facility 2012-01-03 Follow-up Inspection No Violations Noted
2067483 Primary Facility 2012-05-11 Routine/Complete Inspection No Violations Noted
2076763 Primary Facility 2012-06-12 Routine/Complete Inspection No Violations Noted
2094167 Primary Facility 2012-08-23 Routine/Partial Inspection No Violations Noted
2117175 Primary Facility 2012-11-20 Routine/Complete Inspection No Violations Noted
2123235 Primary Facility 2012-12-06 Routine/Complete Inspection No Violations Noted
2132687 Primary Facility 2013-01-22 Routine/Complete Inspection No Violations Noted
2813911 Primary Facility 2018-12-12 Routine/Complete Inspection No Violations Noted Six wells staged for production phase. Six each water separators not within containment. No leaks detected from production equipment. No violations noted.