If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-115-20676 | | Well ID: 37-115-20676 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 41.814722, -75.766053 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 21: | Line 21: | ||
| License Status: Active | | License Status: Active | ||
|- | |- | ||
− | | Spud Date: 10 | + | | Spud Date: 2011-10-25 |
|- | |- | ||
− | | Permit Date: 10 | + | | Permit Date: 2011-10-04 |
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 2012-07-17 | ||
+ | | 2012-07-17 | ||
+ | | style="text-align: right;" | 6677.00 | ||
+ | | style="text-align: right;" | 5,365,500.0 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="17"| 1 | ||
+ | | rowspan="4"| Biocide EC 6116A | ||
+ | | rowspan="4"| Nalco | ||
+ | | rowspan="4"| Acid | ||
+ | | 2,2-Dibromo-3-nitrilopropionamide | ||
+ | | 10222-01-2 | ||
+ | | style="text-align: right;" | 30.00 | ||
+ | | style="text-align: right;" | 0.00701000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Polyethylene glycol | ||
+ | | 25322-68-3 | ||
+ | | style="text-align: right;" | 60.00 | ||
+ | | style="text-align: right;" | 0.01 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Hydrochloric acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 15.00 | ||
+ | | style="text-align: right;" | 0.12 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Dibromoacetonitrile | ||
+ | | 3252-43-5 | ||
+ | | style="text-align: right;" | 5.00 | ||
+ | | style="text-align: right;" | 0.00117000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="4"| AI-250 | ||
+ | | rowspan="4"| Clearwater International | ||
+ | | rowspan="4"| Acid Inhibitor | ||
+ | | 2-Butoxyethanol | ||
+ | | 111-76-2 | ||
+ | | style="text-align: right;" | 40.00 | ||
+ | | style="text-align: right;" | 0.00084000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Propargyl alcohol | ||
+ | | 107-19-7 | ||
+ | | style="text-align: right;" | 40.00 | ||
+ | | style="text-align: right;" | 0.00084000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Isopropanol | ||
+ | | 67-63-0 | ||
+ | | style="text-align: right;" | 40.00 | ||
+ | | style="text-align: right;" | 0.00084000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Ethoxylated Nonylphenol | ||
+ | | | ||
+ | | style="text-align: right;" | 13.00 | ||
+ | | style="text-align: right;" | 0.00027000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| StimLube | ||
+ | | rowspan="1"| Clearwater International | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Distillates, petroleum, hydrotreated light | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 30.00 | ||
+ | | style="text-align: right;" | 0.02 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="4"| FRA-405 | ||
+ | | rowspan="4"| Clearwater International | ||
+ | | rowspan="4"| Friction Reducer | ||
+ | | Distillates, petroleum, hydrotreated light | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 27.50 | ||
+ | | style="text-align: right;" | 0.00623000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Ethoxylated C12-16 alcohols | ||
+ | | 68551-12-2 | ||
+ | | style="text-align: right;" | 5.00 | ||
+ | | style="text-align: right;" | 0.00113000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Sodium chloride | ||
+ | | 7647-14-5 | ||
+ | | style="text-align: right;" | 7.50 | ||
+ | | style="text-align: right;" | 0.00170000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Ammonium chloride | ||
+ | | 12125-02-9 | ||
+ | | style="text-align: right;" | 5.00 | ||
+ | | style="text-align: right;" | 0.00113000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| SI-112 | ||
+ | | rowspan="1"| Clearwater International | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Ethylene glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 40.00 | ||
+ | | style="text-align: right;" | 0.00437000 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="0"| | ||
+ | | rowspan="0"| Southwestern Energy | ||
+ | | rowspan="0"| Sand | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| 15 HCl | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Acid | ||
+ | | Hydrochloric acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 15.00 | ||
+ | | style="text-align: right;" | 0.83 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| | ||
+ | | rowspan="2"| Southwestern Energy | ||
+ | | rowspan="2"| Water/Produced Water | ||
+ | | H2O + Disolved Salts | ||
+ | | | ||
+ | | style="text-align: right;" | 100.00 | ||
+ | | style="text-align: right;" | 90.43 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Quartz | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 100.00 | ||
+ | | style="text-align: right;" | 8.59 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="0"| Biocide EC 6116A | ||
+ | | rowspan="0"| Nalco | ||
+ | | rowspan="0"| Biocide | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =FracFocus Fracking Chemicals Database | ||
+ | | date = 2019-04-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 156: | Line 331: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | + | | 2012-S01 | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | 2012- | ||
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 360.03 Tons | | style="text-align: right;" | 360.03 Tons | ||
Line 222: | Line 337: | ||
| THR029 | | THR029 | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Fracturing Fluid Waste (in Tons) | | Fracturing Fluid Waste (in Tons) | ||
| style="text-align: right;" | 466.36 Tons | | style="text-align: right;" | 466.36 Tons | ||
Line 228: | Line 343: | ||
| 101247 | | 101247 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 2,368.00 Bbl | | style="text-align: right;" | 2,368.00 Bbl | ||
Line 234: | Line 349: | ||
| | | | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 2,390.00 Bbl | | style="text-align: right;" | 2,390.00 Bbl | ||
Line 240: | Line 355: | ||
| | | | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 450.00 Bbl | | style="text-align: right;" | 450.00 Bbl | ||
Line 246: | Line 361: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M05 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 25.20 Bbl | | style="text-align: right;" | 25.20 Bbl | ||
Line 252: | Line 367: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 1.00 Bbl | | style="text-align: right;" | 1.00 Bbl | ||
Line 258: | Line 373: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 11.00 Bbl | | style="text-align: right;" | 11.00 Bbl | ||
Line 264: | Line 379: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 13.00 Bbl | | style="text-align: right;" | 13.00 Bbl | ||
Line 270: | Line 385: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 9.00 Bbl | | style="text-align: right;" | 9.00 Bbl | ||
Line 276: | Line 391: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 68.40 Bbl | | style="text-align: right;" | 68.40 Bbl | ||
Line 282: | Line 397: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 45.60 Bbl | | style="text-align: right;" | 45.60 Bbl | ||
Line 288: | Line 403: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 44.80 Bbl | | style="text-align: right;" | 44.80 Bbl | ||
Line 294: | Line 409: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M12 |
| Fracturing Fluid Waste (in Barrels) RWC 805 | | Fracturing Fluid Waste (in Barrels) RWC 805 | ||
| style="text-align: right;" | 22.80 Bbl | | style="text-align: right;" | 22.80 Bbl | ||
Line 300: | Line 415: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 53.80 Bbl | | style="text-align: right;" | 53.80 Bbl | ||
Line 306: | Line 421: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M07 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 22.40 Bbl | | style="text-align: right;" | 22.40 Bbl | ||
Line 312: | Line 427: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 22.80 Bbl | | style="text-align: right;" | 22.80 Bbl | ||
Line 318: | Line 433: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 45.60 Bbl | | style="text-align: right;" | 45.60 Bbl | ||
Line 324: | Line 439: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 22.00 Bbl | | style="text-align: right;" | 22.00 Bbl | ||
Line 330: | Line 445: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M11 |
| Drilling Fluid Waste (in Barrels) RWC 803 | | Drilling Fluid Waste (in Barrels) RWC 803 | ||
| style="text-align: right;" | 154.80 Bbl | | style="text-align: right;" | 154.80 Bbl | ||
Line 336: | Line 451: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M11 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 11.00 Bbl | | style="text-align: right;" | 11.00 Bbl | ||
Line 342: | Line 457: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 43.20 Bbl | | style="text-align: right;" | 43.20 Bbl | ||
Line 348: | Line 463: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 22.00 Bbl | | style="text-align: right;" | 22.00 Bbl | ||
Line 354: | Line 469: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M01 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 2.00 Bbl | | style="text-align: right;" | 2.00 Bbl | ||
Line 360: | Line 475: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 67.20 Bbl | | style="text-align: right;" | 67.20 Bbl | ||
Line 366: | Line 481: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M02 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 21.73 Bbl | | style="text-align: right;" | 21.73 Bbl | ||
Line 372: | Line 487: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 22.80 Bbl | | style="text-align: right;" | 22.80 Bbl | ||
Line 378: | Line 493: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 22.00 Bbl | | style="text-align: right;" | 22.00 Bbl | ||
Line 384: | Line 499: | ||
| 826342 | | 826342 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M04 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 44.00 Bbl | | style="text-align: right;" | 44.00 Bbl | ||
Line 390: | Line 505: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 47.00 Bbl | | style="text-align: right;" | 47.00 Bbl | ||
Line 396: | Line 511: | ||
| 826342 | | 826342 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M05 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 22.00 Bbl | | style="text-align: right;" | 22.00 Bbl | ||
Line 402: | Line 517: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 22.40 Bbl | | style="text-align: right;" | 22.40 Bbl | ||
Line 408: | Line 523: | ||
| 826342 | | 826342 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 22.00 Bbl | | style="text-align: right;" | 22.00 Bbl | ||
Line 414: | Line 529: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 48.80 Bbl | | style="text-align: right;" | 48.80 Bbl | ||
Line 420: | Line 535: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 60.60 Bbl | | style="text-align: right;" | 60.60 Bbl | ||
Line 426: | Line 541: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 44.80 Bbl | | style="text-align: right;" | 44.80 Bbl | ||
Line 432: | Line 547: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M10 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 22.00 Bbl | | style="text-align: right;" | 22.00 Bbl | ||
Line 438: | Line 553: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 22.00 Bbl | | style="text-align: right;" | 22.00 Bbl | ||
Line 444: | Line 559: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 24.00 Bbl | | style="text-align: right;" | 24.00 Bbl | ||
Line 450: | Line 565: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 22.00 Bbl | | style="text-align: right;" | 22.00 Bbl | ||
Line 456: | Line 571: | ||
| 826342 | | 826342 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 26.40 Bbl | | style="text-align: right;" | 26.40 Bbl | ||
Line 462: | Line 577: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M01 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 3.00 Bbl | | style="text-align: right;" | 3.00 Bbl | ||
Line 468: | Line 583: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 26.00 Bbl | | style="text-align: right;" | 26.00 Bbl | ||
Line 474: | Line 589: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 44.80 Bbl | | style="text-align: right;" | 44.80 Bbl | ||
Line 480: | Line 595: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M03 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 22.00 Bbl | | style="text-align: right;" | 22.00 Bbl | ||
Line 486: | Line 601: | ||
| 95-16-65420-013 | | 95-16-65420-013 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 46.00 Bbl | | style="text-align: right;" | 46.00 Bbl | ||
Line 511: | Line 626: | ||
| 2031176 | | 2031176 | ||
| Primary Facility | | Primary Facility | ||
− | | 01 | + | | 2012-01-03 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 518: | Line 633: | ||
| 2074435 | | 2074435 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2012-05-31 |
| Follow-up Inspection | | Follow-up Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 525: | Line 640: | ||
| 2110216 | | 2110216 | ||
| Primary Facility | | Primary Facility | ||
− | | 10 | + | | 2012-10-15 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| Pending | | Pending | ||
Line 532: | Line 647: | ||
| 2177178 | | 2177178 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2013-05-21 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 653: | Line 768: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> |
Well ID: 37-115-20676 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.814722,"lon":-75.766053,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: New Milford Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 145736 | |
Farm/Lease Name: ZEFFER 3H | |
License Status: Active | |
Spud Date: 2011-10-25 | |
Permit Date: 2011-10-04 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.814722 | |
Longitude: -75.766053 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-07-17 | 2012-07-17 | 6677.00 | 5,365,500.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Biocide EC 6116A | Nalco | Acid | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30.00 | 0.00701000 | |
Polyethylene glycol | 25322-68-3 | 60.00 | 0.01 | |||||
Hydrochloric acid | 7647-01-0 | 15.00 | 0.12 | |||||
Dibromoacetonitrile | 3252-43-5 | 5.00 | 0.00117000 | |||||
AI-250 | Clearwater International | Acid Inhibitor | 2-Butoxyethanol | 111-76-2 | 40.00 | 0.00084000 | ||
Propargyl alcohol | 107-19-7 | 40.00 | 0.00084000 | |||||
Isopropanol | 67-63-0 | 40.00 | 0.00084000 | |||||
Ethoxylated Nonylphenol | 13.00 | 0.00027000 | ||||||
StimLube | Clearwater International | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | ||
FRA-405 | Clearwater International | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 27.50 | 0.00623000 | ||
Ethoxylated C12-16 alcohols | 68551-12-2 | 5.00 | 0.00113000 | |||||
Sodium chloride | 7647-14-5 | 7.50 | 0.00170000 | |||||
Ammonium chloride | 12125-02-9 | 5.00 | 0.00113000 | |||||
SI-112 | Clearwater International | Scale Inhibitor | Ethylene glycol | 107-21-1 | 40.00 | 0.00437000 | ||
Southwestern Energy | Sand | |||||||
15 HCl | Nalco | Acid | Hydrochloric acid | 7647-01-0 | 15.00 | 0.83 | ||
Southwestern Energy | Water/Produced Water | H2O + Disolved Salts | 100.00 | 90.43 | ||||
Quartz | 14808-60-7 | 100.00 | 8.59 | |||||
Biocide EC 6116A | Nalco | Biocide |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SOUTHWESTERN ENERGY PROD CO | 148,948.00 | 34 | 0.00 | 0 | 0.00 | 0 |
2013 | SOUTHWESTERN ENERGY PROD CO | 2,293,487.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | SOUTHWESTERN ENERGY PROD CO | 1,319,777.00 | 307 | 0.00 | 0 | 0.00 | 0 |
2015 | SOUTHWESTERN ENERGY PROD CO | 1,227,541.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | SWN PROD CO LLC | 1,015,078.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | SWN PROD CO LLC | 691,296.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2018 | SWN PROD CO LLC | 658,949.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | SWN PROD CO LLC | 162,958.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2012-S01 | Drill Cuttings (in Tons) | 360.03 Tons | LANDFILL | THR029 |
2012-S02 | Fracturing Fluid Waste (in Tons) | 466.36 Tons | LANDFILL | 101247 |
2013-S01 | Produced Fluid (in Barrels) | 2,368.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S02 | Produced Fluid (in Barrels) | 2,390.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Produced Fluid (in Barrels) | 450.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M05 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 25.20 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M05 | Produced Fluid (in Barrels) RWC 802 | 1.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M06 | Produced Fluid (in Barrels) RWC 802 | 11.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M07 | Produced Fluid (in Barrels) RWC 802 | 13.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M08 | Produced Fluid (in Barrels) RWC 802 | 9.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M09 | Produced Fluid (in Barrels) RWC 802 | 68.40 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M10 | Produced Fluid (in Barrels) RWC 802 | 45.60 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M11 | Produced Fluid (in Barrels) RWC 802 | 44.80 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M12 | Fracturing Fluid Waste (in Barrels) RWC 805 | 22.80 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M12 | Produced Fluid (in Barrels) RWC 802 | 53.80 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017-M07 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 22.40 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 22.80 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 45.60 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 22.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M11 | Drilling Fluid Waste (in Barrels) RWC 803 | 154.80 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M11 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 11.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M11 | Produced Fluid (in Barrels) RWC 802 | 43.20 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 22.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M01 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 2.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 67.20 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 21.73 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 22.80 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 22.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018-M04 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 44.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 47.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018-M05 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 22.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 22.40 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 22.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 48.80 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 60.60 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 44.80 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018-M10 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 22.00 Bbl | REUSE (AT WELL PAD) | |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 22.00 Bbl | REUSE (AT WELL PAD) | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 24.00 Bbl | REUSE (AT WELL PAD) | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 22.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 26.40 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019-M01 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 3.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 26.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 44.80 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019-M03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 22.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 46.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2031176 | Primary Facility | 2012-01-03 | Drilling/Alteration | No Violations Noted | DDI-10...Co. man - Joe Davis. Circulating at time of inspection. Depth of drilling = 7665'. Walked site with Co. Man. Secondary containment in place. Drillers log on site and up to date. Cement reports show adequate cement quantities. |
2074435 | Primary Facility | 2012-05-31 | Follow-up Inspection | No Violations Noted | Well drilled. operator reported bubbling outside of casing. At time of inspection I observed minor bubbling between 9 5/8" and 13 3/8" casings. No other bubbling observed. No activity on site. Secondary containment still down around well. Will Follow up with Operator on condition of well. No violations observed at this time. Well tag and site i.d. sign in place. |
2110216 | Primary Facility | 2012-10-15 | Routine/Complete Inspection | Pending | DDI-10 on site drilling Zeffer 2H. During inspection checked cellar - observed bubbling in cellar of 3H. Consistent bubbling outside 9 5/8" approximately 1/4" in size. Cellar half full of water so could not see source of bubbling. Requested Operator to pump down cellar and identify source and report to DEP. Copy of detailed Summary Sheet provided for this well by Co. Man. at time of inspection. Violation is Pending. |
2177178 | Primary Facility | 2013-05-21 | Routine/Complete Inspection | No Violations Noted | Please see the Zeffer 1H inspection report for details. Permit number is 115-21089. |
2467805 | Primary Facility | 2016-03-21 | Routine/Complete Inspection | No Violations Noted | On 3/21/16, the Department conducted an inspection of the SWN RU 29 Zeffer Pad and the 2 impoundments. The small impoundment was inspected first. The new liner has been installed. Normal operations are now occurring. During the inspection 2 water trucks were observed off-loading to this impoundment. All equipment associated with the dewatering and solids removal of the small impoundment has been removed. As suggested by the Department, the soil has been removed and replaced from the area between the off-loading concrete pad and the small impoundment. The disturbed areas has been seeded and mulched. The small impoundment appears to be about 1/3 full and the large impoundment appears to be approximately 1/3 full. All of the slopes associated with the pad and impoundments were inspected and appeared stable and well vegetated. No violations noted. |
2482672 | Primary Facility | 2016-05-10 | Routine/Complete Inspection | No Violations Noted | |
2509163 | Primary Facility | 2016-08-03 | Routine/Complete Inspection | No Violations Noted | On 8/3/16, the Department conducted an inspection of the SWN Zeffer Well Pad and Impoundment’s 1 and 2. Also present during the inspection were Eric Rooney, Department Geologist and Mike Deming, SWN Senior Regulatory Analyst. Mr. Rooney was on-site evaluating SWN’s efforts in meeting their Work Plan submitted by CB&I consulting dated March 10, 2016, titled in part as “Additional Hydrogeologic Investigation Report for the Zeffer Impoundments.” At the time of the inspection, a small drill rig was on-site collecting core samples next to Monitoring Well # 8. This activity is being conducted to ensure that the monitoring well was constructed and installed properly based on the localized geology. A review of the large and small impoundment found that they were below the 2’ free board level required of waste water impoundments. The large impoundment had a free board level of about 4’, while the small impoundment was in the range of 5’. A review of the well pad found that there is good vegetative stability, a |
2555324 | Primary Facility | 2017-01-25 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 13:05p.m., the cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The vent pipe was open and set up with a Taylor plug to check for pressure and the valve going to the production tank was closed. There was 677psi on the production casing and 526psi on the production line. I took a walk around the location and there were no obvious concerns noticed.
I left the site at 13:50p.m. |
2646759 | Primary Facility | 2017-10-12 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. I took a walk around the location and there were no obvious concerns noticed. |
2693649 | Primary Facility | 2018-02-09 | Routine/Complete Inspection | No Violations Noted | Today's inspection was conducted as a routine inspection. No E&S issues noted. No violations noted. |
2736053 | Primary Facility | 2018-05-23 | Routine/Complete Inspection | No Violations Noted | The department arrived on sited at 1220 hrs to conduct a RTNC inspection of the Zeffer 29 Well Pad. The department was represented by Casey Baldwin (DEP-WQS) and myself.
Upon arrival at the pad, it was noted that the proper signage was displayed at the entrance to the pad's access road, and the appropriate paperwork was present in the mailbox. The access road appeared solid and stable, with no apparent erosion even after substantial rains during the past few days. No E&S issues were observed, and all PCSM stormwater management BMPs were present and in good condition. Mr. Baldwin and I departed the pad at 1320 hrs. |
2751705 | Primary Facility | 2018-07-13 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2844410 | Primary Facility | 2019-02-22 | Routine/Complete Inspection | No Violations Noted | Today's inspection was conducted as a routine inspection. As the photo's show, the site is snow covered. Overall the site appears to have good stabilization. No E&S issues identified. No violations noted. |
2852359 | Primary Facility | 2019-03-12 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar with a MSA Altair 5X multi gas detector that was calibrated on 3/4/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |