{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-115-21223 | | Well ID: 37-115-21223 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 41.798317, -75.704883 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 21: | Line 21: | ||
| License Status: Active | | License Status: Active | ||
|- | |- | ||
− | | Spud Date: 06 | + | | Spud Date: 2013-06-27 |
|- | |- | ||
− | | Permit Date: | + | | Permit Date: 2013-04-09 |
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 2013-10-11 | ||
+ | | 2013-10-22 | ||
+ | | style="text-align: right;" | 6953 | ||
+ | | style="text-align: right;" | 13,723,700.0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="25"| 1 | ||
+ | | rowspan="4"| Plexbreak 145 | ||
+ | | rowspan="4"| Chemplex | ||
+ | | rowspan="4"| Non-Emulsifier | ||
+ | | Methyl Alcohol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 15 | ||
+ | | style="text-align: right;" | 0.000140074 | ||
+ | | style="text-align: right;" | 182.655 | ||
+ | |- | ||
+ | | 2-Butoxyethanol | ||
+ | | 111-76-2 | ||
+ | | style="text-align: right;" | 15 | ||
+ | | style="text-align: right;" | 0.000140074 | ||
+ | | style="text-align: right;" | 182.655 | ||
+ | |- | ||
+ | | Diethanolamine | ||
+ | | 111-42-2 | ||
+ | | style="text-align: right;" | 3 | ||
+ | | style="text-align: right;" | 0.00002801 | ||
+ | | style="text-align: right;" | 36.531 | ||
+ | |- | ||
+ | | Cocamide Based Surfactant | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00009338 | ||
+ | | style="text-align: right;" | 121.77 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Water | ||
+ | | rowspan="1"| Rain for Rent | ||
+ | | rowspan="1"| Carrier/Base Fluid | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 88.316 | ||
+ | | style="text-align: right;" | 115,163,000.0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="5"| Plexhib 256 | ||
+ | | rowspan="5"| Chemplex | ||
+ | | rowspan="5"| Acid Inhibitor | ||
+ | | Polyethoxylated Alcohol Surfactant | ||
+ | | 68951-67-7 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.000250966 | ||
+ | | style="text-align: right;" | 327.258 | ||
+ | |- | ||
+ | | Thiourea/Formaldehyde Copolymer | ||
+ | | 68527-49-1 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.000250966 | ||
+ | | style="text-align: right;" | 327.258 | ||
+ | |- | ||
+ | | Propargyl Alcohol | ||
+ | | 107-19-7 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00008366 | ||
+ | | style="text-align: right;" | 109.086 | ||
+ | |- | ||
+ | | Methyl Alcohol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.000501933 | ||
+ | | style="text-align: right;" | 654.515 | ||
+ | |- | ||
+ | | C-14 to C-16 Alpha Olefins | ||
+ | | 64743-02-8 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00004183 | ||
+ | | style="text-align: right;" | 54.543 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Hydrochloric Acid (15%) | ||
+ | | rowspan="1"| Reagent | ||
+ | | rowspan="1"| Acidizing | ||
+ | | Hydrochloric Acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 15 | ||
+ | | style="text-align: right;" | 0.0787525 | ||
+ | | style="text-align: right;" | 102692 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="4"| Plexslick 957 | ||
+ | | rowspan="4"| Chemplex | ||
+ | | rowspan="4"| Friction Reducer | ||
+ | | Paraffinic, Naphtehenic Solvent | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.0191068 | ||
+ | | style="text-align: right;" | 24915 | ||
+ | |- | ||
+ | | Poly (acrylamide-co-acrylic acid), partial sodium salt | ||
+ | | 62649-23-4 | ||
+ | | style="text-align: right;" | 35 | ||
+ | | style="text-align: right;" | 0.0222912 | ||
+ | | style="text-align: right;" | 29067.5 | ||
+ | |- | ||
+ | | Nonionic Surfactants | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 1.5 | ||
+ | | style="text-align: right;" | 0.000955338 | ||
+ | | style="text-align: right;" | 1245.75 | ||
+ | |- | ||
+ | | Ammonium Chloride | ||
+ | | 12125-02-9 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00318446 | ||
+ | | style="text-align: right;" | 4152.5 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="3"| Ferriplex 40 | ||
+ | | rowspan="3"| Chemplex | ||
+ | | rowspan="3"| Iron Control | ||
+ | | Sodium Hydroxide | ||
+ | | 1310-73-2 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.00002845 | ||
+ | | style="text-align: right;" | 37.102 | ||
+ | |- | ||
+ | | Sodium Sulfate Anhydrous | ||
+ | | 7757-82-6 | ||
+ | | style="text-align: right;" | 2 | ||
+ | | style="text-align: right;" | 0.00005691 | ||
+ | | style="text-align: right;" | 74.204 | ||
+ | |- | ||
+ | | Trisodium Nitrilotriacetate | ||
+ | | 5064-31-3 | ||
+ | | style="text-align: right;" | 40 | ||
+ | | style="text-align: right;" | 0.0011381 | ||
+ | | style="text-align: right;" | 1484.08 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="4"| Plexcide 15G | ||
+ | | rowspan="4"| Chemplex | ||
+ | | rowspan="4"| Biocide | ||
+ | | Ethanol | ||
+ | | 64-17-5 | ||
+ | | style="text-align: right;" | 3 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 887.178 | ||
+ | |- | ||
+ | | Glutaraldehyde | ||
+ | | 111-30-8 | ||
+ | | style="text-align: right;" | 14 | ||
+ | | style="text-align: right;" | 0.003175 | ||
+ | | style="text-align: right;" | 4140.16 | ||
+ | |- | ||
+ | | Alkyl Dimethyl Benzyl Ammonium Chloride | ||
+ | | 68424-85-1 | ||
+ | | style="text-align: right;" | 3 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 887.178 | ||
+ | |- | ||
+ | | Didecyl Dimethyl Ammonium Chloride | ||
+ | | 7173-51-5 | ||
+ | | style="text-align: right;" | 3 | ||
+ | | style="text-align: right;" | 0.000680357 | ||
+ | | style="text-align: right;" | 887.178 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Sand (Proppant) | ||
+ | | rowspan="1"| TSS | ||
+ | | rowspan="1"| Proppant | ||
+ | | Silica Substrate | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 11.0437 | ||
+ | | style="text-align: right;" | 14,400,800.0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| Greenhib 679 | ||
+ | | rowspan="2"| Chemplex | ||
+ | | rowspan="2"| Friction Reducer | ||
+ | | Glycerine | ||
+ | | 56-81-5 | ||
+ | | style="text-align: right;" | 20 | ||
+ | | style="text-align: right;" | 0.00487537 | ||
+ | | style="text-align: right;" | 6357.42 | ||
+ | |- | ||
+ | | Proprietary | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 35 | ||
+ | | style="text-align: right;" | 0.00853189 | ||
+ | | style="text-align: right;" | 11125.5 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =FracFocus Fracking Chemicals Database | ||
+ | | date = 2019-04-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 138: | Line 361: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 1,012.72 Tons | | style="text-align: right;" | 1,012.72 Tons | ||
Line 144: | Line 367: | ||
| 101247 | | 101247 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 297.12 Tons | | style="text-align: right;" | 297.12 Tons | ||
Line 150: | Line 373: | ||
| THR029 | | THR029 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 118.50 Bbl | | style="text-align: right;" | 118.50 Bbl | ||
Line 156: | Line 379: | ||
| WMGR123NE001 | | WMGR123NE001 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 225.00 Bbl | | style="text-align: right;" | 225.00 Bbl | ||
Line 162: | Line 385: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 1,539.00 Bbl | | style="text-align: right;" | 1,539.00 Bbl | ||
Line 168: | Line 391: | ||
| WMGR123NE001 | | WMGR123NE001 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 3,740.00 Bbl | | style="text-align: right;" | 3,740.00 Bbl | ||
Line 174: | Line 397: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 20,296.00 Bbl | | style="text-align: right;" | 20,296.00 Bbl | ||
Line 180: | Line 403: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 111.00 Bbl | | style="text-align: right;" | 111.00 Bbl | ||
Line 186: | Line 409: | ||
| WMGR123NE001 | | WMGR123NE001 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 6,487.31 Bbl | | style="text-align: right;" | 6,487.31 Bbl | ||
Line 192: | Line 415: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 7.50 Bbl | | style="text-align: right;" | 7.50 Bbl | ||
Line 198: | Line 421: | ||
| WMGR123NE001 | | WMGR123NE001 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 2,461.02 Bbl | | style="text-align: right;" | 2,461.02 Bbl | ||
Line 204: | Line 427: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 5.00 Bbl | | style="text-align: right;" | 5.00 Bbl | ||
Line 210: | Line 433: | ||
| WMGR123NE001 | | WMGR123NE001 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 1,749.38 Bbl | | style="text-align: right;" | 1,749.38 Bbl | ||
Line 216: | Line 439: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 1,298.80 Bbl | | style="text-align: right;" | 1,298.80 Bbl | ||
Line 222: | Line 445: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2016- | + | | 2016-S01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 968.51 Bbl | | style="text-align: right;" | 968.51 Bbl | ||
Line 228: | Line 451: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2016- | + | | 2016-S02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 56.45 Bbl | | style="text-align: right;" | 56.45 Bbl | ||
Line 234: | Line 457: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2016- | + | | 2016-S02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 855.54 Bbl | | style="text-align: right;" | 855.54 Bbl | ||
Line 240: | Line 463: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 184.85 Bbl | | style="text-align: right;" | 184.85 Bbl | ||
Line 246: | Line 469: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 159.84 Bbl | | style="text-align: right;" | 159.84 Bbl | ||
Line 252: | Line 475: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 81.37 Bbl | | style="text-align: right;" | 81.37 Bbl | ||
Line 258: | Line 481: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 61.66 Bbl | | style="text-align: right;" | 61.66 Bbl | ||
Line 264: | Line 487: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 89.37 Bbl | | style="text-align: right;" | 89.37 Bbl | ||
Line 270: | Line 493: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 47.88 Bbl | | style="text-align: right;" | 47.88 Bbl | ||
Line 276: | Line 499: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 131.12 Bbl | | style="text-align: right;" | 131.12 Bbl | ||
Line 282: | Line 505: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 115.34 Bbl | | style="text-align: right;" | 115.34 Bbl | ||
Line 288: | Line 511: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 53.87 Bbl | | style="text-align: right;" | 53.87 Bbl | ||
Line 294: | Line 517: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 55.68 Bbl | | style="text-align: right;" | 55.68 Bbl | ||
Line 300: | Line 523: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 106.30 Bbl | | style="text-align: right;" | 106.30 Bbl | ||
Line 306: | Line 529: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 126.81 Bbl | | style="text-align: right;" | 126.81 Bbl | ||
Line 312: | Line 535: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 97.82 Bbl | | style="text-align: right;" | 97.82 Bbl | ||
Line 318: | Line 541: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 176.44 Bbl | | style="text-align: right;" | 176.44 Bbl | ||
Line 324: | Line 547: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 128.63 Bbl | | style="text-align: right;" | 128.63 Bbl | ||
Line 330: | Line 553: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 97.49 Bbl | | style="text-align: right;" | 97.49 Bbl | ||
Line 336: | Line 559: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 73.91 Bbl | | style="text-align: right;" | 73.91 Bbl | ||
Line 342: | Line 565: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 40.23 Bbl | | style="text-align: right;" | 40.23 Bbl | ||
Line 348: | Line 571: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 71.06 Bbl | | style="text-align: right;" | 71.06 Bbl | ||
Line 354: | Line 577: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 46.21 Bbl | | style="text-align: right;" | 46.21 Bbl | ||
Line 360: | Line 583: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 10.55 Bbl | | style="text-align: right;" | 10.55 Bbl | ||
Line 366: | Line 589: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 129.70 Bbl | | style="text-align: right;" | 129.70 Bbl | ||
Line 372: | Line 595: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 147.91 Bbl | | style="text-align: right;" | 147.91 Bbl | ||
Line 378: | Line 601: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 105.65 Bbl | | style="text-align: right;" | 105.65 Bbl | ||
Line 384: | Line 607: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 65.96 Bbl | | style="text-align: right;" | 65.96 Bbl | ||
Line 390: | Line 613: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 42.22 Bbl | | style="text-align: right;" | 42.22 Bbl | ||
Line 396: | Line 619: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 108.93 Bbl | | style="text-align: right;" | 108.93 Bbl | ||
Line 402: | Line 625: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 50.27 Bbl | | style="text-align: right;" | 50.27 Bbl | ||
Line 408: | Line 631: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 117.95 Bbl | | style="text-align: right;" | 117.95 Bbl | ||
Line 414: | Line 637: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 157.83 Bbl | | style="text-align: right;" | 157.83 Bbl | ||
Line 420: | Line 643: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 156.39 Bbl | | style="text-align: right;" | 156.39 Bbl | ||
Line 426: | Line 649: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 132.67 Bbl | | style="text-align: right;" | 132.67 Bbl | ||
Line 432: | Line 655: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 145.55 Bbl | | style="text-align: right;" | 145.55 Bbl | ||
Line 438: | Line 661: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 109.83 Bbl | | style="text-align: right;" | 109.83 Bbl | ||
Line 444: | Line 667: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 48.66 Bbl | | style="text-align: right;" | 48.66 Bbl | ||
Line 450: | Line 673: | ||
| WMGR123NE002 | | WMGR123NE002 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 108.49 Bbl | | style="text-align: right;" | 108.49 Bbl | ||
Line 456: | Line 679: | ||
| WMGR123NE004 | | WMGR123NE004 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 114.21 Bbl | | style="text-align: right;" | 114.21 Bbl | ||
Line 481: | Line 704: | ||
| 2179928 | | 2179928 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2013-07-02 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 488: | Line 711: | ||
| 2180030 | | 2180030 | ||
| Primary Facility | | Primary Facility | ||
− | | 06 | + | | 2013-06-25 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 495: | Line 718: | ||
| 2231985 | | 2231985 | ||
| Primary Facility | | Primary Facility | ||
− | | 12 | + | | 2013-12-11 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 502: | Line 725: | ||
| 2238465 | | 2238465 | ||
| Primary Facility | | Primary Facility | ||
− | | 01 | + | | 2014-01-23 |
| Administrative/File Review | | Administrative/File Review | ||
| Pending | | Pending | ||
Line 509: | Line 732: | ||
| 2262826 | | 2262826 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2014-04-16 |
| Administrative/File Review | | Administrative/File Review | ||
| Viol(s) Noted & Immediately Corrected | | Viol(s) Noted & Immediately Corrected | ||
Line 613: | Line 836: | ||
| 693345 | | 693345 | ||
| 04/16/2014 | | 04/16/2014 | ||
− | | 04 | + | | 2014-04-16 |
| 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 637: | Line 860: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> |
Well ID: 37-115-21223 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.798317,"lon":-75.704883,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Harford Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 146436 | |
Farm/Lease Name: PRITCHARD D 1 | |
License Status: Active | |
Spud Date: 2013-06-27 | |
Permit Date: 2013-04-09 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.798317 | |
Longitude: -75.704883 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-10-11 | 2013-10-22 | 6953 | 13,723,700.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Plexbreak 145 | Chemplex | Non-Emulsifier | Methyl Alcohol | 67-56-1 | 15 | 0.000140074 | 182.655 |
2-Butoxyethanol | 111-76-2 | 15 | 0.000140074 | 182.655 | ||||
Diethanolamine | 111-42-2 | 3 | 0.00002801 | 36.531 | ||||
Cocamide Based Surfactant | Proprietary | 10 | 0.00009338 | 121.77 | ||||
Water | Rain for Rent | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 88.316 | 115,163,000.0 | |
Plexhib 256 | Chemplex | Acid Inhibitor | Polyethoxylated Alcohol Surfactant | 68951-67-7 | 30 | 0.000250966 | 327.258 | |
Thiourea/Formaldehyde Copolymer | 68527-49-1 | 30 | 0.000250966 | 327.258 | ||||
Propargyl Alcohol | 107-19-7 | 10 | 0.00008366 | 109.086 | ||||
Methyl Alcohol | 67-56-1 | 60 | 0.000501933 | 654.515 | ||||
C-14 to C-16 Alpha Olefins | 64743-02-8 | 5 | 0.00004183 | 54.543 | ||||
Hydrochloric Acid (15%) | Reagent | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.0787525 | 102692 | |
Plexslick 957 | Chemplex | Friction Reducer | Paraffinic, Naphtehenic Solvent | 64742-47-8 | 30 | 0.0191068 | 24915 | |
Poly (acrylamide-co-acrylic acid), partial sodium salt | 62649-23-4 | 35 | 0.0222912 | 29067.5 | ||||
Nonionic Surfactants | Proprietary | 1.5 | 0.000955338 | 1245.75 | ||||
Ammonium Chloride | 12125-02-9 | 5 | 0.00318446 | 4152.5 | ||||
Ferriplex 40 | Chemplex | Iron Control | Sodium Hydroxide | 1310-73-2 | 1 | 0.00002845 | 37.102 | |
Sodium Sulfate Anhydrous | 7757-82-6 | 2 | 0.00005691 | 74.204 | ||||
Trisodium Nitrilotriacetate | 5064-31-3 | 40 | 0.0011381 | 1484.08 | ||||
Plexcide 15G | Chemplex | Biocide | Ethanol | 64-17-5 | 3 | 0 | 887.178 | |
Glutaraldehyde | 111-30-8 | 14 | 0.003175 | 4140.16 | ||||
Alkyl Dimethyl Benzyl Ammonium Chloride | 68424-85-1 | 3 | 0 | 887.178 | ||||
Didecyl Dimethyl Ammonium Chloride | 7173-51-5 | 3 | 0.000680357 | 887.178 | ||||
Sand (Proppant) | TSS | Proppant | Silica Substrate | 14808-60-7 | 100 | 11.0437 | 14,400,800.0 | |
Greenhib 679 | Chemplex | Friction Reducer | Glycerine | 56-81-5 | 20 | 0.00487537 | 6357.42 | |
Proprietary | Proprietary | 35 | 0.00853189 | 11125.5 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | CABOT OIL & GAS CORP | 727,469.93 | 48 | 0.00 | 0 | 0.00 | 0 |
2014 | CABOT OIL & GAS CORP | 4,158,172.65 | 362 | 0.00 | 0 | 0.00 | 0 |
2015 | CABOT OIL & GAS CORP | 2,033,711.12 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 1,623,790.66 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 1,192,843.30 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 1,040,455.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 244,757.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2013-S02 | Drill Cuttings (in Tons) | 1,012.72 Tons | LANDFILL | 101247 |
2013-S02 | Drill Cuttings (in Tons) | 297.12 Tons | LANDFILL | THR029 |
2013-S02 | Drilling Fluid Waste (in Barrels) | 118.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2013-S02 | Drilling Fluid Waste (in Barrels) | 225.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2013-S02 | Fracing Fluid Waste (in Barrels) | 1,539.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2013-S02 | Fracing Fluid Waste (in Barrels) | 3,740.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2013-S02 | Produced Fluid (in Barrels) | 20,296.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2014-S01 | Produced Fluid (in Barrels) | 111.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2014-S01 | Produced Fluid (in Barrels) | 6,487.31 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2014-S02 | Produced Fluid (in Barrels) | 7.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2014-S02 | Produced Fluid (in Barrels) | 2,461.02 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015-S01 | Produced Fluid (in Barrels) | 5.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2015-S01 | Produced Fluid (in Barrels) | 1,749.38 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015-S02 | Produced Fluid (in Barrels) | 1,298.80 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 968.51 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 56.45 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE004 |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 855.54 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 184.85 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017-M02 | Produced Fluid (in Barrels) RWC 802 | 159.84 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 81.37 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 61.66 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 89.37 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 47.88 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2017-M05 | Produced Fluid (in Barrels) RWC 802 | 131.12 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 115.34 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 53.87 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 55.68 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 106.30 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 126.81 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 97.82 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 176.44 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017-M11 | Produced Fluid (in Barrels) RWC 802 | 128.63 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 97.49 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 73.91 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 40.23 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 71.06 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 46.21 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 10.55 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 129.70 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 147.91 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 105.65 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 65.96 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 42.22 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 108.93 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 50.27 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 117.95 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 157.83 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 156.39 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 132.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 145.55 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 109.83 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 48.66 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 108.49 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 114.21 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2179928 | Primary Facility | 2013-07-02 | Drilling/Alteration | No Violations Noted | Spudder rig on location |
2180030 | Primary Facility | 2013-06-25 | Routine/Complete Inspection | No Violations Noted | The Department was on site at the D Pritchard Well Site to conduct a Preoperational Inspection. Well permits that have been issued for this pad are the 1H (115-21223), 2H (115-21224), and the 3H (115-21225). Inspection conducted with Eric Griffin of Don Bower Construction and Dillon Otten field tech for Tioga Environmental Consulting. All perimeter BMP’s in place. Red lined diversion berm reconfiguration located on the northeast side of the pad is acceptable. Pad is approximately 80% complete. |
2231985 | Primary Facility | 2013-12-11 | Routine/Complete Inspection | No Violations Noted | Inspection conducted on 12/11/13. Inspection conducted in response to a complaint that pad design and installation is causing increased storm water flow to agricultural field. Ground is frozen and snow covered. Pad placement does not appear as if would increase storm water flow to field in question. |
2238465 | Primary Facility | 2014-01-23 | Administrative/File Review | Pending | On 1/21/14, Andy Mehalko reported the following incident: On 1/20/14 at approximately 10:00 AM a release of approximately 5-6 gallons of glycol solution was identified at the Pritchard 1H well. Due to an issue with the thermostat on the GPU, the burner unit overheated the glycol solution causing it to flow, as designed, into the adjacent overflow tank. At this point, due to the volume and temperature of the fluid transferred, it escaped the primary overflow tank and was captured by the secondary containment system consisting of an overpack type drum. Unfortunately, the drain valve at the bottom of the overpack drum was not fully seated allowing a portion of the fluid to migrate to the pad surface. |
2262826 | Primary Facility | 2014-04-16 | Administrative/File Review | Viol(s) Noted & Immediately Corrected | This administrative inspection has been created to document Cabot’s remediation of the small spill which occurred on their Pritchard, D. Pad documented in the 1/23/14 inspection record # 2238465. A review of the remediation summary report prepared by Resource Environmental indicates that the remediation was adequate. No further action is required of Cabot at this time. Attached is a copy of the remediation summary report, the waste manifest associated with this spill, and the 1/23/14 inspection. |
2476528 | Primary Facility | 2016-04-20 | Routine/Complete Inspection | No Violations Noted | |
2486951 | Primary Facility | 2016-05-23 | Routine/Complete Inspection | No Violations Noted | |
2502677 | Primary Facility | 2016-07-18 | Routine/Complete Inspection | No Violations Noted | |
2510521 | Primary Facility | 2016-08-11 | Routine/Partial Inspection | No Violations Noted | |
2533885 | Primary Facility | 2016-11-01 | Routine/Complete Inspection | No Violations Noted | On 11/1/16, the Department conducted an inspection of the COG Pritchard D Well Site located in Harford Township, Susquehanna County in response to a nearby malodor complaint. The Department arrived on-site at approximately 12:00 AM. There are 2 wells drilled and in production on this pad, the 1H and 2H. The pad is equipped with the standard equipment associated with steady state production. A water truck was collecting produced fluid from the production tanks during the inspection. No other activity is occurring at this pad. I spent approximately 5 minutes at each corner of the well pad and did not detect any malodors. No E&S issues were observed during this inspection. No violations noted. |
2582540 | Primary Facility | 2017-04-12 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 14:20p.m.
The cellar was about a quarter full of water with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into the production tank, the (9x5) annulus vent pipe was open and venting into the production tank. There was 498psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:45p.m. |
2688197 | Primary Facility | 2018-01-30 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The cellar had water about 6.5' below grade and there was no bubbling noticed. The (20x13) annulus was above the water level and there was no gas detected. The (13x9) and (9x5) annuli vent pipes were connected together and venting to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2737674 | Primary Facility | 2018-06-04 | Routine/Complete Inspection | No Violations Noted | Today's inspection was conducted as a routine inspection. No E&S issues identified. No violations noted. |
2786347 | Primary Facility | 2018-10-10 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water 6.5' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same production tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2834854 | Primary Facility | 2019-01-31 | Routine/Complete Inspection | No Violations Noted | Today's inspection was conducted as a routine inspection. As the photo's show, the site is snow covered. Production tank containment should be emptied the next time the stormwater melts, as there is not much free board present. Overall the site has good stabilization. No E&S issues identified. No violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2262826 | 693345 | 04/16/2014 | 2014-04-16 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety |
For data sources see[7]