If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-115-21776 | | Well ID: 37-115-21776 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 41.832222, -75.732125 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 21: | Line 21: | ||
| License Status: Plugged OG Well | | License Status: Plugged OG Well | ||
|- | |- | ||
− | | Spud Date: 07 | + | | Spud Date: 2014-07-01 |
|- | |- | ||
− | | Permit Date: | + | | Permit Date: 2014-06-06 |
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | <!--== Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | |}--> | ||
+ | <!--==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |}--> | ||
+ | |||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 111: | Line 136: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | | | + | | 2016-M02 |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 40.00 Bbl | | style="text-align: right;" | 40.00 Bbl | ||
Line 135: | Line 142: | ||
| | | | ||
|- | |- | ||
− | | | + | | 2016-M03 |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 33.00 Bbl | | style="text-align: right;" | 33.00 Bbl | ||
Line 153: | Line 148: | ||
| | | | ||
|- | |- | ||
− | + | | 2016-M04 | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | 2016- | ||
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 31.00 Bbl | | style="text-align: right;" | 31.00 Bbl | ||
Line 195: | Line 154: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 27.00 Bbl | | style="text-align: right;" | 27.00 Bbl | ||
Line 201: | Line 160: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 34.00 Bbl | | style="text-align: right;" | 34.00 Bbl | ||
Line 207: | Line 166: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 37.00 Bbl | | style="text-align: right;" | 37.00 Bbl | ||
Line 213: | Line 172: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 34.00 Bbl | | style="text-align: right;" | 34.00 Bbl | ||
Line 219: | Line 178: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 193.50 Bbl | | style="text-align: right;" | 193.50 Bbl | ||
Line 225: | Line 184: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 180.50 Bbl | | style="text-align: right;" | 180.50 Bbl | ||
Line 231: | Line 190: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 155.88 Bbl | | style="text-align: right;" | 155.88 Bbl | ||
Line 237: | Line 196: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 122.86 Bbl | | style="text-align: right;" | 122.86 Bbl | ||
Line 262: | Line 221: | ||
| 2285174 | | 2285174 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2014-07-09 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 269: | Line 228: | ||
| 2299618 | | 2299618 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2014-08-26 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 276: | Line 235: | ||
| 2300087 | | 2300087 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2014-08-28 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 283: | Line 242: | ||
| 2329097 | | 2329097 | ||
| Primary Facility | | Primary Facility | ||
− | | 12 | + | | 2014-12-15 |
| Incident- Response to Accident or Event | | Incident- Response to Accident or Event | ||
| No Violations Noted | | No Violations Noted | ||
Line 290: | Line 249: | ||
| 2366961 | | 2366961 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2015-05-01 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 297: | Line 256: | ||
| 2375448 | | 2375448 | ||
| Primary Facility | | Primary Facility | ||
− | | 06 | + | | 2015-06-02 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 406: | Line 365: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> | ||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
[[Category:Pennsylvania Wells]] | [[Category:Pennsylvania Wells]] |
Well ID: 37-115-21776 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.832222,"lon":-75.732125,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: New Milford Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 148583 | |
Farm/Lease Name: INNES NORTH 4H | |
License Status: Plugged OG Well | |
Spud Date: 2014-07-01 | |
Permit Date: 2014-06-06 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.832222 | |
Longitude: -75.732125 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | SWN PROD CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | SWN PROD CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2016-M02 | Produced Fluid (in Barrels) RWC 802 | 40.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M03 | Produced Fluid (in Barrels) RWC 802 | 33.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M04 | Produced Fluid (in Barrels) RWC 802 | 31.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M05 | Produced Fluid (in Barrels) RWC 802 | 27.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M06 | Produced Fluid (in Barrels) RWC 802 | 34.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M07 | Produced Fluid (in Barrels) RWC 802 | 37.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M08 | Produced Fluid (in Barrels) RWC 802 | 34.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M09 | Produced Fluid (in Barrels) RWC 802 | 193.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M10 | Produced Fluid (in Barrels) RWC 802 | 180.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M11 | Produced Fluid (in Barrels) RWC 802 | 155.88 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-M12 | Produced Fluid (in Barrels) RWC 802 | 122.86 Bbl | REUSE OTHER THAN ROAD SPREADING |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2285174 | Primary Facility | 2014-07-09 | Drilling/Alteration | No Violations Noted | Well spud 7/1/14 - conductor set. Rig expected to move on location 7/11/14 |
2299618 | Primary Facility | 2014-08-26 | Routine/Complete Inspection | No Violations Noted | Falcon Rig# 18 is the active drilling rig on the location. Laddie Pendergraft is the company man on location. The current drilling depth is (4,740) feet. I observed a relatively large hole in the composite mats surveying the drilling rig containment system. Beneath the composite mats are layers of felt and a (40) mil HDPE liner. Mr. Pendergraft said the hole will be repaired today. The secondary containment as part of the drilling rig and associated equipment appeared to be in good condition as well as did the production equipment secondary containment. The fluid levels in the drill cuttings containers and Keystone Landfill containers did not exceed the (2)’ freeboard requirement of Title 25, Env. Protection, Pa. code 78.56. |
2300087 | Primary Facility | 2014-08-28 | Drilling/Alteration | No Violations Noted | |
2329097 | Primary Facility | 2014-12-15 | Incident- Response to Accident or Event | No Violations Noted | Arrived at the site at 12:00 in response to reported spills of (3-5) barrels of flowback water and (50) gallons of antifreeze. Hydraulic fracturing operations were in progress. Keane Frac is the subcontractor conducting well stimulation (frac) procedures on Innes South 8H well. Justin Phillips, Health, Safety and Environmental Staff Coordinator Supervisor of SWN reported the estimated (3-5) barrel capacity spill flowback water spill that occurred on containment to the Department at 9:30 PM on 12/13/14. Chris Becker, Health, Safety & Environmental staff Coordinator of SWN reported the estimated (50) gallon antifreeze spill to the Department on 12/14/14 at 2:30 PM. There is no evidence the spills escaped secondary containment, no evidence of comprised liner integrity and no evidence of an impact to the pad surface in the general area where the spills occurred. Both spills occurred due to mechanical malfunction according to SWN. |
2366961 | Primary Facility | 2015-05-01 | Routine/Complete Inspection | No Violations Noted | |
2375448 | Primary Facility | 2015-06-02 | Routine/Complete Inspection | No Violations Noted | |
2452231 | Primary Facility | 2016-02-23 | Routine/Complete Inspection | No Violations Noted | |
2477413 | Primary Facility | 2016-04-22 | Routine/Complete Inspection | No Violations Noted | |
2488539 | Primary Facility | 2016-05-31 | Routine/Complete Inspection | No Violations Noted | |
2561203 | Primary Facility | 2017-02-06 | Routine/Complete Inspection | Pending | At time of inspection, arrived on site at 13:20p.m. There were seven wells on the site that were in production (1H, 2H, 3H, 5H, 6H, 7H, and 8H).
The 4H was conductor only. Original permit date was 6/6/2014. Expiration date was 6/6/2015. Spud date was 7/1/2014. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:10p.m. |
2562295 | Primary Facility | 2017-02-16 | Administrative/File Review | Violation(s) Noted | Administrative Inspection follow-up to RTNC Inspection 2561203. The Innes North 4H was spud July 1, 2014, the well permit expired June 6, 2015 and no drilling activity has occurred since the well was spud. Because the Innes North 4H has not been drilled to total depth to enable production of gas since the well was spud in June 2014, the Innes North 4H is therefore an abandoned well, which SWN has failed to plug.
The Innes 4H was plugged 5/17/2017. The Plugging Certificate was received 6/30/2017 and was reviewed/approved on 7/3/2017. VIOL resolved as CRCTD and Enforcement Record 351093 updated to Comply/Closed on the date the PLUGC was approved (7/3/2017). SWNPC indicated in their NOV response that the Surface Hole Location (SHL) for the Innes 4H conductor was inadvertently reversed with the SHL for the Innes 8H (115-21799), so SWN will submit a permit modification to reflect the accurate as-drilled conditions for the Innes 8H. ~CMB~ |
2598060 | Primary Facility | 2017-05-25 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Route inspection of the now plugged Innes 4H (conductor). The well is cut below grade, capped, and marked with API # and plug date 5-17-17. No Issues. |
2609991 | Primary Facility | 2017-07-03 | Administrative/File Review | No Violations Noted | July 3, 2017: Plugging Certificate has been received, reviewed, signed, and sent to file. This well is a plugged conductor, and there were no obvious major issues noted on the plugging certificate. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2562295 | 778575 | 2017-02-16 | 2017-07-03 | 78a91(a) | Environmental Health & Safety | The Innes North 4H is a conductor-only well that was spud in 2014, has had no drilling activity since and has no active well permit, and is therefore an abandoned well. |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
778575 | 351093 | NOV - Notice of Violation | 2017-07-03 |
For data sources see[6]