If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-117-21581 | | Well ID: 37-117-21581 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 41.557833, -77.079122 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 21: | Line 21: | ||
| License Status: Active | | License Status: Active | ||
|- | |- | ||
− | | Spud Date: 11 | + | | Spud Date: 2012-11-16 |
|- | |- | ||
− | | Permit Date: | + | | Permit Date: 2012-08-23 |
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 2013-05-14 | ||
+ | | 2013-05-22 | ||
+ | | style="text-align: right;" | 6561 | ||
+ | | style="text-align: right;" | 6,643,480.0 | ||
+ | | style="text-align: right;" | 419076 | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="32"| 1 | ||
+ | | rowspan="1"| Water | ||
+ | | rowspan="1"| Operator | ||
+ | | rowspan="1"| Base Carrier Fluid | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 86.647 | ||
+ | | style="text-align: right;" | 55,406,600.0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| FE-4 | ||
+ | | rowspan="2"| Chemplex, L.C. | ||
+ | | rowspan="2"| Iron Control Additive | ||
+ | | Citric Acid Anhydrous | ||
+ | | 77-92-9 | ||
+ | | style="text-align: right;" | 55 | ||
+ | | style="text-align: right;" | 0.000925793 | ||
+ | | style="text-align: right;" | 592 | ||
+ | |- | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 55 | ||
+ | | style="text-align: right;" | 0.000925793 | ||
+ | | style="text-align: right;" | 592 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="4"| Petro-Flo | ||
+ | | rowspan="4"| Bio-Cide International, Inc | ||
+ | | rowspan="4"| Biocide | ||
+ | | Sodium Carbonate | ||
+ | | 497-19-8 | ||
+ | | style="text-align: right;" | 2 | ||
+ | | style="text-align: right;" | 0.000961761 | ||
+ | | style="text-align: right;" | 615 | ||
+ | |- | ||
+ | | Sodium Chloride | ||
+ | | 7647-14-5 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.000481662 | ||
+ | | style="text-align: right;" | 308 | ||
+ | |- | ||
+ | | Sodium Chlorite | ||
+ | | 7758-19-2 | ||
+ | | style="text-align: right;" | 8.35 | ||
+ | | style="text-align: right;" | 0.0040175 | ||
+ | | style="text-align: right;" | 2569 | ||
+ | |- | ||
+ | | Sodium Hydroxide | ||
+ | | 1310-73-2 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.000481662 | ||
+ | | style="text-align: right;" | 308 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| MSI-7 | ||
+ | | rowspan="1"| National Petrochem | ||
+ | | rowspan="1"| Scale Inhibitor | ||
+ | | Hydrogen Chloride | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00875593 | ||
+ | | style="text-align: right;" | 5599 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| SG-14G | ||
+ | | rowspan="1"| Benchmark Energy Products LLC | ||
+ | | rowspan="1"| Gellant | ||
+ | | Guar Gum | ||
+ | | 9000-30-0 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.0390991 | ||
+ | | style="text-align: right;" | 25002 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="3"| BF-470 | ||
+ | | rowspan="3"| Benchmark | ||
+ | | rowspan="3"| Buffer | ||
+ | | Potassium Hydroxide | ||
+ | | 1310-58-3 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.00005786 | ||
+ | | style="text-align: right;" | 37 | ||
+ | |- | ||
+ | | Potassium Carbonate | ||
+ | | 584-08-7 | ||
+ | | style="text-align: right;" | 47 | ||
+ | | style="text-align: right;" | 0.00269449 | ||
+ | | style="text-align: right;" | 1723 | ||
+ | |- | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 57 | ||
+ | | style="text-align: right;" | 0.00326686 | ||
+ | | style="text-align: right;" | 2089 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| FR900 | ||
+ | | rowspan="1"| Nalco | ||
+ | | rowspan="1"| Friction Reducer | ||
+ | | Proprietary | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.0707934 | ||
+ | | style="text-align: right;" | 45269 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Plexgel Breaker 10L | ||
+ | | rowspan="1"| Chemplex, L.C. | ||
+ | | rowspan="1"| Breaker | ||
+ | | No Hazardous Ingredients | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.000172022 | ||
+ | | style="text-align: right;" | 110 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| 15% Hydrochloric Acid | ||
+ | | rowspan="2"| Reagent | ||
+ | | rowspan="2"| Scale Dissolver | ||
+ | | 36% Hydrochloric Acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 15 | ||
+ | | style="text-align: right;" | 0.0725496 | ||
+ | | style="text-align: right;" | 46392 | ||
+ | |- | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 85 | ||
+ | | style="text-align: right;" | 0.411116 | ||
+ | | style="text-align: right;" | 262889 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| EDTA-ACID | ||
+ | | rowspan="2"| Univar | ||
+ | | rowspan="2"| Iron Control | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.00000469 | ||
+ | | style="text-align: right;" | 3 | ||
+ | |- | ||
+ | | Ethylenediaminetetraacetic acid | ||
+ | | 60-00-4 | ||
+ | | style="text-align: right;" | 99 | ||
+ | | style="text-align: right;" | 0.000473843 | ||
+ | | style="text-align: right;" | 303 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Plexgel 907 | ||
+ | | rowspan="1"| Chemplex, L.C. | ||
+ | | rowspan="1"| Gellant | ||
+ | | Guar Gum | ||
+ | | 9000-30-0 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.0186503 | ||
+ | | style="text-align: right;" | 11926 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| CX-14G | ||
+ | | rowspan="2"| Benchmark | ||
+ | | rowspan="2"| Crosslinker | ||
+ | | Petroleum Distillates | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00787393 | ||
+ | | style="text-align: right;" | 5035 | ||
+ | |- | ||
+ | | Organic alcohol | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00787393 | ||
+ | | style="text-align: right;" | 5035 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Sand | ||
+ | | rowspan="1"| Operator | ||
+ | | rowspan="1"| Proppant | ||
+ | | Silicon Dioxide | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 12.6382 | ||
+ | | style="text-align: right;" | 8,081,540.0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="9"| I-22 | ||
+ | | rowspan="9"| Nalco | ||
+ | | rowspan="9"| Corrosion Inhibitor | ||
+ | | Aromatic aldehyde | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.000511375 | ||
+ | | style="text-align: right;" | 327 | ||
+ | |- | ||
+ | | Isopropanol | ||
+ | | 67-63-0 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.000170458 | ||
+ | | style="text-align: right;" | 109 | ||
+ | |- | ||
+ | | Quaternary ammonium compound | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00008601 | ||
+ | | style="text-align: right;" | 55 | ||
+ | |- | ||
+ | | Oxyalkylated Fatty Acid Derivative | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.000511375 | ||
+ | | style="text-align: right;" | 327 | ||
+ | |- | ||
+ | | Cyclic alkanes | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00008601 | ||
+ | | style="text-align: right;" | 55 | ||
+ | |- | ||
+ | | 2-Mercaptoethyl Alcohol | ||
+ | | 60-24-2 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00008601 | ||
+ | | style="text-align: right;" | 55 | ||
+ | |- | ||
+ | | Quaternary ammonium compound | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.000511375 | ||
+ | | style="text-align: right;" | 327 | ||
+ | |- | ||
+ | | Methanol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00008601 | ||
+ | | style="text-align: right;" | 55 | ||
+ | |- | ||
+ | | Formic Acid | ||
+ | | 64-18-6 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.00102431 | ||
+ | | style="text-align: right;" | 655 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| SP breaker | ||
+ | | rowspan="1"| Multiple Suppliers | ||
+ | | rowspan="1"| Breaker | ||
+ | | Sodium Persulfate | ||
+ | | 7775-27-1 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00201579 | ||
+ | | style="text-align: right;" | 1289 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =FracFocus Fracking Chemicals Database | ||
+ | | date = 2019-04-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 147: | Line 436: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 1,327.88 Tons | | style="text-align: right;" | 1,327.88 Tons | ||
Line 153: | Line 442: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 12.00 Bbl | | style="text-align: right;" | 12.00 Bbl | ||
Line 159: | Line 448: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 87.62 Bbl | | style="text-align: right;" | 87.62 Bbl | ||
Line 165: | Line 454: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2012- | + | | 2012-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 40.00 Bbl | | style="text-align: right;" | 40.00 Bbl | ||
Line 171: | Line 460: | ||
| WMGR123NC006 | | WMGR123NC006 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S01 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 613.37 Tons | | style="text-align: right;" | 613.37 Tons | ||
Line 177: | Line 466: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S01 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 238.90 Bbl | | style="text-align: right;" | 238.90 Bbl | ||
Line 183: | Line 472: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S01 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 65.60 Bbl | | style="text-align: right;" | 65.60 Bbl | ||
Line 189: | Line 478: | ||
| WMGR123NC006 | | WMGR123NC006 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S01 |
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 617.02 Bbl | | style="text-align: right;" | 617.02 Bbl | ||
Line 195: | Line 484: | ||
| | | | ||
|- | |- | ||
− | | 2013- | + | | 2013-S01 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 409.55 Bbl | | style="text-align: right;" | 409.55 Bbl | ||
Line 201: | Line 490: | ||
| | | | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 5.43 Tons | | style="text-align: right;" | 5.43 Tons | ||
Line 207: | Line 496: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 52.50 Bbl | | style="text-align: right;" | 52.50 Bbl | ||
Line 213: | Line 502: | ||
| WMGR119 | | WMGR119 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 233.86 Bbl | | style="text-align: right;" | 233.86 Bbl | ||
Line 219: | Line 508: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 6.98 Bbl | | style="text-align: right;" | 6.98 Bbl | ||
Line 225: | Line 514: | ||
| 7-3115-00193 | | 7-3115-00193 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 5,176.18 Bbl | | style="text-align: right;" | 5,176.18 Bbl | ||
Line 231: | Line 520: | ||
| | | | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 31.75 Bbl | | style="text-align: right;" | 31.75 Bbl | ||
Line 237: | Line 526: | ||
| WMGR119 | | WMGR119 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 165.86 Bbl | | style="text-align: right;" | 165.86 Bbl | ||
Line 243: | Line 532: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2013- | + | | 2013-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 4,698.55 Bbl | | style="text-align: right;" | 4,698.55 Bbl | ||
Line 249: | Line 538: | ||
| | | | ||
|- | |- | ||
− | | 2014- | + | | 2014-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 6,288.94 Bbl | | style="text-align: right;" | 6,288.94 Bbl | ||
Line 255: | Line 544: | ||
| | | | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Drill Cuttings (in Tons) | | Drill Cuttings (in Tons) | ||
| style="text-align: right;" | 0.02 Tons | | style="text-align: right;" | 0.02 Tons | ||
Line 261: | Line 550: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 51.86 Bbl | | style="text-align: right;" | 51.86 Bbl | ||
Line 267: | Line 556: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 214.26 Bbl | | style="text-align: right;" | 214.26 Bbl | ||
Line 273: | Line 562: | ||
| | | | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 275.05 Bbl | | style="text-align: right;" | 275.05 Bbl | ||
Line 279: | Line 568: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2014- | + | | 2014-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 1,516.79 Bbl | | style="text-align: right;" | 1,516.79 Bbl | ||
Line 285: | Line 574: | ||
| | | | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Fracing Fluid Waste (in Barrels) | | Fracing Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 74.84 Bbl | | style="text-align: right;" | 74.84 Bbl | ||
Line 291: | Line 580: | ||
| | | | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 183.37 Bbl | | style="text-align: right;" | 183.37 Bbl | ||
Line 297: | Line 586: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S01 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 1,029.91 Bbl | | style="text-align: right;" | 1,029.91 Bbl | ||
Line 303: | Line 592: | ||
| | | | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 30.23 Bbl | | style="text-align: right;" | 30.23 Bbl | ||
Line 309: | Line 598: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 500.93 Bbl | | style="text-align: right;" | 500.93 Bbl | ||
Line 315: | Line 604: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2015- | + | | 2015-S02 |
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 444.69 Bbl | | style="text-align: right;" | 444.69 Bbl | ||
Line 321: | Line 610: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-S02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 100.02 Bbl | | style="text-align: right;" | 100.02 Bbl | ||
Line 327: | Line 616: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2016- | + | | 2016-S02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 1,595.26 Bbl | | style="text-align: right;" | 1,595.26 Bbl | ||
Line 333: | Line 622: | ||
| | | | ||
|- | |- | ||
− | | 2016- | + | | 2016-S02 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 0.26 Tons | | style="text-align: right;" | 0.26 Tons | ||
Line 339: | Line 628: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 33.33 Bbl | | style="text-align: right;" | 33.33 Bbl | ||
Line 345: | Line 634: | ||
| WMGR123NC018 | | WMGR123NC018 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 33.33 Bbl | | style="text-align: right;" | 33.33 Bbl | ||
Line 351: | Line 640: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 133.33 Bbl | | style="text-align: right;" | 133.33 Bbl | ||
Line 357: | Line 646: | ||
| WMGR123NC022 | | WMGR123NC022 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 33.33 Bbl | | style="text-align: right;" | 33.33 Bbl | ||
Line 363: | Line 652: | ||
| WMGR123NC022 | | WMGR123NC022 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 133.33 Bbl | | style="text-align: right;" | 133.33 Bbl | ||
Line 369: | Line 658: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M04 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 233.33 Bbl | | style="text-align: right;" | 233.33 Bbl | ||
Line 375: | Line 664: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M04 |
| Waste Water Treatment Sludge (in Tons) RWC 804 | | Waste Water Treatment Sludge (in Tons) RWC 804 | ||
| style="text-align: right;" | 2.06 Tons | | style="text-align: right;" | 2.06 Tons | ||
Line 381: | Line 670: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M05 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 143.00 Bbl | | style="text-align: right;" | 143.00 Bbl | ||
Line 387: | Line 676: | ||
| WMGR123NC022 | | WMGR123NC022 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 233.33 Bbl | | style="text-align: right;" | 233.33 Bbl | ||
Line 393: | Line 682: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 133.33 Bbl | | style="text-align: right;" | 133.33 Bbl | ||
Line 399: | Line 688: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 54.20 Bbl | | style="text-align: right;" | 54.20 Bbl | ||
Line 405: | Line 694: | ||
| WMGR123NC010 | | WMGR123NC010 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 133.33 Bbl | | style="text-align: right;" | 133.33 Bbl | ||
Line 411: | Line 700: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 35.03 Bbl | | style="text-align: right;" | 35.03 Bbl | ||
Line 417: | Line 706: | ||
| WMGR123NC010 | | WMGR123NC010 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 16.00 Bbl | | style="text-align: right;" | 16.00 Bbl | ||
Line 423: | Line 712: | ||
| WMGR123NC022 | | WMGR123NC022 | ||
|- | |- | ||
− | | 2017- | + | | 2017-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 116.67 Bbl | | style="text-align: right;" | 116.67 Bbl | ||
Line 429: | Line 718: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 158.00 Bbl | | style="text-align: right;" | 158.00 Bbl | ||
Line 435: | Line 724: | ||
| | | | ||
|- | |- | ||
− | | 2017- | + | | 2017-M12 |
| Waste Water Treatment Sludge (in Tons) RWC 804 | | Waste Water Treatment Sludge (in Tons) RWC 804 | ||
| style="text-align: right;" | 1.33 Tons | | style="text-align: right;" | 1.33 Tons | ||
Line 441: | Line 730: | ||
| PA-0678 | | PA-0678 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 115.00 Bbl | | style="text-align: right;" | 115.00 Bbl | ||
Line 447: | Line 736: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 311.00 Bbl | | style="text-align: right;" | 311.00 Bbl | ||
Line 453: | Line 742: | ||
| WMGR123NC010 | | WMGR123NC010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 140.92 Bbl | | style="text-align: right;" | 140.92 Bbl | ||
Line 459: | Line 748: | ||
| WMGR123NC010 | | WMGR123NC010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 146.67 Bbl | | style="text-align: right;" | 146.67 Bbl | ||
Line 465: | Line 754: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 1,198.00 Bbl | | style="text-align: right;" | 1,198.00 Bbl | ||
Line 471: | Line 760: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M06 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 2.20 Tons | | style="text-align: right;" | 2.20 Tons | ||
Line 477: | Line 766: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 83.40 Bbl | | style="text-align: right;" | 83.40 Bbl | ||
Line 483: | Line 772: | ||
| WMGR123NC010 | | WMGR123NC010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 130.00 Bbl | | style="text-align: right;" | 130.00 Bbl | ||
Line 489: | Line 778: | ||
| WMGR123 | | WMGR123 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 841.12 Bbl | | style="text-align: right;" | 841.12 Bbl | ||
Line 495: | Line 784: | ||
| WMGR123NC010 | | WMGR123NC010 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 17.00 Bbl | | style="text-align: right;" | 17.00 Bbl | ||
Line 501: | Line 790: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Produced Fluid (in Tons) RWC 802 | | Produced Fluid (in Tons) RWC 802 | ||
| style="text-align: right;" | 14.06 Tons | | style="text-align: right;" | 14.06 Tons | ||
Line 507: | Line 796: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M07 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 0.95 Tons | | style="text-align: right;" | 0.95 Tons | ||
Line 513: | Line 802: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M08 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 50.00 Bbl | | style="text-align: right;" | 50.00 Bbl | ||
Line 519: | Line 808: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M08 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 0.77 Tons | | style="text-align: right;" | 0.77 Tons | ||
Line 525: | Line 814: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M09 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 63.00 Bbl | | style="text-align: right;" | 63.00 Bbl | ||
Line 531: | Line 820: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M09 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 225.00 Bbl | | style="text-align: right;" | 225.00 Bbl | ||
Line 537: | Line 826: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M09 |
| Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | | Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | ||
| style="text-align: right;" | 31.05 Tons | | style="text-align: right;" | 31.05 Tons | ||
Line 543: | Line 832: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M09 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 2.81 Tons | | style="text-align: right;" | 2.81 Tons | ||
Line 549: | Line 838: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M10 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 126.00 Bbl | | style="text-align: right;" | 126.00 Bbl | ||
Line 555: | Line 844: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M11 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 40.00 Bbl | | style="text-align: right;" | 40.00 Bbl | ||
Line 561: | Line 850: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M11 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 0.99 Tons | | style="text-align: right;" | 0.99 Tons | ||
Line 567: | Line 856: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2018- | + | | 2018-M12 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 64.80 Bbl | | style="text-align: right;" | 64.80 Bbl | ||
Line 573: | Line 862: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M12 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 71.00 Bbl | | style="text-align: right;" | 71.00 Bbl | ||
Line 579: | Line 868: | ||
| | | | ||
|- | |- | ||
− | | 2018- | + | | 2018-M12 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 0.54 Tons | | style="text-align: right;" | 0.54 Tons | ||
Line 585: | Line 874: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M01 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 497.80 Bbl | | style="text-align: right;" | 497.80 Bbl | ||
Line 591: | Line 880: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M02 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 227.33 Bbl | | style="text-align: right;" | 227.33 Bbl | ||
Line 597: | Line 886: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M02 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 70.00 Bbl | | style="text-align: right;" | 70.00 Bbl | ||
Line 603: | Line 892: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M02 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 6.88 Tons | | style="text-align: right;" | 6.88 Tons | ||
Line 609: | Line 898: | ||
| 301358 | | 301358 | ||
|- | |- | ||
− | | 2019- | + | | 2019-M03 |
| Other Oil & Gas Wastes (in Barrels) RWC 899 | | Other Oil & Gas Wastes (in Barrels) RWC 899 | ||
| style="text-align: right;" | 231.60 Bbl | | style="text-align: right;" | 231.60 Bbl | ||
Line 615: | Line 904: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M03 |
| Produced Fluid (in Barrels) RWC 802 | | Produced Fluid (in Barrels) RWC 802 | ||
| style="text-align: right;" | 154.40 Bbl | | style="text-align: right;" | 154.40 Bbl | ||
Line 621: | Line 910: | ||
| | | | ||
|- | |- | ||
− | | 2019- | + | | 2019-M03 |
| Synthetic Liner Materials (in Tons) RWC 806 | | Synthetic Liner Materials (in Tons) RWC 806 | ||
| style="text-align: right;" | 3.71 Tons | | style="text-align: right;" | 3.71 Tons | ||
Line 646: | Line 935: | ||
| 2118703 | | 2118703 | ||
| Primary Facility | | Primary Facility | ||
− | | 11 | + | | 2012-11-19 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| Violation(s) Noted | | Violation(s) Noted | ||
Line 653: | Line 942: | ||
| 2128612 | | 2128612 | ||
| Primary Facility | | Primary Facility | ||
− | | 01 | + | | 2013-01-02 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 660: | Line 949: | ||
| 2182245 | | 2182245 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2013-07-10 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 667: | Line 956: | ||
| 2194641 | | 2194641 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2013-08-07 |
| Incident- Response to Accident or Event | | Incident- Response to Accident or Event | ||
| Violation(s) Noted | | Violation(s) Noted | ||
Line 674: | Line 963: | ||
| 2207574 | | 2207574 | ||
| Primary Facility | | Primary Facility | ||
− | | 09 | + | | 2013-09-25 |
| Follow-up Inspection | | Follow-up Inspection | ||
| Outstanding Violations - Viols Req'd | | Outstanding Violations - Viols Req'd | ||
Line 681: | Line 970: | ||
| 2215560 | | 2215560 | ||
| Primary Facility | | Primary Facility | ||
− | | 10 | + | | 2013-10-22 |
| Follow-up Inspection | | Follow-up Inspection | ||
| Outstanding Violations - No Viols Req'd | | Outstanding Violations - No Viols Req'd | ||
Line 688: | Line 977: | ||
| 2230609 | | 2230609 | ||
| Primary Facility | | Primary Facility | ||
− | | 12 | + | | 2013-12-18 |
| Compliance Evaluation | | Compliance Evaluation | ||
| No Violations Noted | | No Violations Noted | ||
Line 695: | Line 984: | ||
| 2265736 | | 2265736 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2014-04-23 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 702: | Line 991: | ||
| 2361294 | | 2361294 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2015-04-15 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 709: | Line 998: | ||
| 2363488 | | 2363488 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2015-04-08 |
| Administrative/File Review | | Administrative/File Review | ||
| No Violations Noted | | No Violations Noted | ||
Line 789: | Line 1,078: | ||
| 654540 | | 654540 | ||
| 11/19/2012 | | 11/19/2012 | ||
− | | | + | | 2012-11-19 |
| 201F - Failure to notify DEP, landowner, political subdivision, or coal owner 24 hrs prior to commencement of drilling | | 201F - Failure to notify DEP, landowner, political subdivision, or coal owner 24 hrs prior to commencement of drilling | ||
| Administrative | | Administrative | ||
Line 797: | Line 1,086: | ||
| 654541 | | 654541 | ||
| 11/19/2012 | | 11/19/2012 | ||
− | | | + | | 2012-11-19 |
| 201E - Failure to comply with terms and conditions of permit | | 201E - Failure to comply with terms and conditions of permit | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 805: | Line 1,094: | ||
| 674910 | | 674910 | ||
| 08/07/2013 | | 08/07/2013 | ||
− | | | + | | 2013-08-07 |
| 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 813: | Line 1,102: | ||
| 674911 | | 674911 | ||
| 08/07/2013 | | 08/07/2013 | ||
− | | | + | | 2013-08-07 |
| 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 821: | Line 1,110: | ||
| 674912 | | 674912 | ||
| 08/07/2013 | | 08/07/2013 | ||
− | | | + | | 2013-08-07 |
| SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 829: | Line 1,118: | ||
| 679028 | | 679028 | ||
| 09/25/2013 | | 09/25/2013 | ||
− | | | + | | 2013-09-25 |
| 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 837: | Line 1,126: | ||
| 679029 | | 679029 | ||
| 09/25/2013 | | 09/25/2013 | ||
− | | | + | | 2013-09-25 |
| 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 845: | Line 1,134: | ||
| 679030 | | 679030 | ||
| 09/25/2013 | | 09/25/2013 | ||
− | | | + | | 2013-09-25 |
| SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | ||
| Environmental Health & Safety | | Environmental Health & Safety | ||
Line 853: | Line 1,142: | ||
| 679031 | | 679031 | ||
| 09/25/2013 | | 09/25/2013 | ||
− | | | + | | 2013-09-25 |
| 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | | 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | ||
| Administrative | | Administrative | ||
Line 875: | Line 1,164: | ||
| Comply/Closed | | Comply/Closed | ||
| | | | ||
− | | 11 | + | | 2014-11-12 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
| style="text-align: right;" | | | style="text-align: right;" | | ||
Line 884: | Line 1,173: | ||
| Comply/Closed | | Comply/Closed | ||
| | | | ||
− | | 11 | + | | 2014-11-12 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
| style="text-align: right;" | | | style="text-align: right;" | | ||
Line 893: | Line 1,182: | ||
| Comply/Closed | | Comply/Closed | ||
| | | | ||
− | | 10 | + | | 2013-10-25 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
| style="text-align: right;" | | | style="text-align: right;" | | ||
Line 902: | Line 1,191: | ||
| Comply/Closed | | Comply/Closed | ||
| | | | ||
− | | 10 | + | | 2013-10-25 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
| style="text-align: right;" | | | style="text-align: right;" | | ||
Line 911: | Line 1,200: | ||
| Comply/Closed | | Comply/Closed | ||
| | | | ||
− | | 10 | + | | 2013-10-25 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
| style="text-align: right;" | | | style="text-align: right;" | | ||
Line 920: | Line 1,209: | ||
| Comply/Closed | | Comply/Closed | ||
| | | | ||
− | | 12 | + | | 2013-12-19 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
| style="text-align: right;" | | | style="text-align: right;" | | ||
Line 929: | Line 1,218: | ||
| Comply/Closed | | Comply/Closed | ||
| | | | ||
− | | 12 | + | | 2013-12-19 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
| style="text-align: right;" | | | style="text-align: right;" | | ||
Line 938: | Line 1,227: | ||
| Comply/Closed | | Comply/Closed | ||
| | | | ||
− | | 12 | + | | 2013-12-19 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
| style="text-align: right;" | | | style="text-align: right;" | | ||
Line 947: | Line 1,236: | ||
| Comply/Closed | | Comply/Closed | ||
| | | | ||
− | | 12 | + | | 2013-12-19 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
| style="text-align: right;" | | | style="text-align: right;" | | ||
Line 958: | Line 1,247: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> |
Well ID: 37-117-21581 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.557833,"lon":-77.079122,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Liberty Township | |
Operator Name: ROCKDALE MARCELLUS LLC | |
Well Pad ID: 145419 | |
Farm/Lease Name: LYNN D 719W 1H | |
License Status: Active | |
Spud Date: 2012-11-16 | |
Permit Date: 2012-08-23 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.557833 | |
Longitude: -77.079122 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-05-14 | 2013-05-22 | 6561 | 6,643,480.0 | 419076 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Water | Operator | Base Carrier Fluid | Water | 7732-18-5 | 100 | 86.647 | 55,406,600.0 |
FE-4 | Chemplex, L.C. | Iron Control Additive | Citric Acid Anhydrous | 77-92-9 | 55 | 0.000925793 | 592 | |
Water | 7732-18-5 | 55 | 0.000925793 | 592 | ||||
Petro-Flo | Bio-Cide International, Inc | Biocide | Sodium Carbonate | 497-19-8 | 2 | 0.000961761 | 615 | |
Sodium Chloride | 7647-14-5 | 1 | 0.000481662 | 308 | ||||
Sodium Chlorite | 7758-19-2 | 8.35 | 0.0040175 | 2569 | ||||
Sodium Hydroxide | 1310-73-2 | 1 | 0.000481662 | 308 | ||||
MSI-7 | National Petrochem | Scale Inhibitor | Hydrogen Chloride | 7647-01-0 | 100 | 0.00875593 | 5599 | |
SG-14G | Benchmark Energy Products LLC | Gellant | Guar Gum | 9000-30-0 | 60 | 0.0390991 | 25002 | |
BF-470 | Benchmark | Buffer | Potassium Hydroxide | 1310-58-3 | 1 | 0.00005786 | 37 | |
Potassium Carbonate | 584-08-7 | 47 | 0.00269449 | 1723 | ||||
Water | 7732-18-5 | 57 | 0.00326686 | 2089 | ||||
FR900 | Nalco | Friction Reducer | Proprietary | Proprietary | 100 | 0.0707934 | 45269 | |
Plexgel Breaker 10L | Chemplex, L.C. | Breaker | No Hazardous Ingredients | Proprietary | 100 | 0.000172022 | 110 | |
15% Hydrochloric Acid | Reagent | Scale Dissolver | 36% Hydrochloric Acid | 7647-01-0 | 15 | 0.0725496 | 46392 | |
Water | 7732-18-5 | 85 | 0.411116 | 262889 | ||||
EDTA-ACID | Univar | Iron Control | Water | 7732-18-5 | 1 | 0.00000469 | 3 | |
Ethylenediaminetetraacetic acid | 60-00-4 | 99 | 0.000473843 | 303 | ||||
Plexgel 907 | Chemplex, L.C. | Gellant | Guar Gum | 9000-30-0 | 100 | 0.0186503 | 11926 | |
CX-14G | Benchmark | Crosslinker | Petroleum Distillates | Proprietary | 100 | 0.00787393 | 5035 | |
Organic alcohol | Proprietary | 100 | 0.00787393 | 5035 | ||||
Sand | Operator | Proppant | Silicon Dioxide | 14808-60-7 | 100 | 12.6382 | 8,081,540.0 | |
I-22 | Nalco | Corrosion Inhibitor | Aromatic aldehyde | Proprietary | 30 | 0.000511375 | 327 | |
Isopropanol | 67-63-0 | 10 | 0.000170458 | 109 | ||||
Quaternary ammonium compound | Proprietary | 5 | 0.00008601 | 55 | ||||
Oxyalkylated Fatty Acid Derivative | Proprietary | 30 | 0.000511375 | 327 | ||||
Cyclic alkanes | Proprietary | 5 | 0.00008601 | 55 | ||||
2-Mercaptoethyl Alcohol | 60-24-2 | 5 | 0.00008601 | 55 | ||||
Quaternary ammonium compound | Proprietary | 30 | 0.000511375 | 327 | ||||
Methanol | 67-56-1 | 5 | 0.00008601 | 55 | ||||
Formic Acid | 64-18-6 | 60 | 0.00102431 | 655 | ||||
SP breaker | Multiple Suppliers | Breaker | Sodium Persulfate | 7775-27-1 | 100 | 0.00201579 | 1289 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | SWEPI LP | 839,191.30 | 117 | 0.00 | 0 | 0.00 | 0 |
2014 | SWEPI LP | 1,760,934.38 | 363 | 0.00 | 0 | 0.00 | 0 |
2015 | SWEPI LP | 1,198,092.32 | 361 | 0.00 | 0 | 0.00 | 0 |
2016 | SWEPI LP | 939,944.75 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | SWEPI LP | 742,803.76 | 362 | 0.00 | 0 | 0.00 | 0 |
2018 | ROCKDALE MARCELLUS LLC | 563,250.00 | 335 | 0.00 | 0 | 0.00 | 0 |
2019 | ROCKDALE MARCELLUS LLC | 127,593.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2012-S02 | Drill Cuttings (in Tons) | 1,327.88 Tons | LANDFILL | 301358 |
2012-S02 | Drilling Fluid Waste (in Barrels) | 12.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2012-S02 | Fracing Fluid Waste (in Barrels) | 87.62 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2012-S02 | Produced Fluid (in Barrels) | 40.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC006 |
2013-S01 | Drill Cuttings (in Tons) | 613.37 Tons | LANDFILL | 301358 |
2013-S01 | Drilling Fluid Waste (in Barrels) | 238.90 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013-S01 | Drilling Fluid Waste (in Barrels) | 65.60 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC006 |
2013-S01 | Drilling Fluid Waste (in Barrels) | 617.02 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S01 | Fracing Fluid Waste (in Barrels) | 409.55 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S02 | Drill Cuttings (in Tons) | 5.43 Tons | LANDFILL | 301358 |
2013-S02 | Fracing Fluid Waste (in Barrels) | 52.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2013-S02 | Fracing Fluid Waste (in Barrels) | 233.86 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013-S02 | Fracing Fluid Waste (in Barrels) | 6.98 Bbl | RESIDUAL WASTE TRANSFER FACILITY | 7-3115-00193 |
2013-S02 | Fracing Fluid Waste (in Barrels) | 5,176.18 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S02 | Produced Fluid (in Barrels) | 31.75 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2013-S02 | Produced Fluid (in Barrels) | 165.86 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013-S02 | Produced Fluid (in Barrels) | 4,698.55 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S01 | Produced Fluid (in Barrels) | 6,288.94 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S02 | Drill Cuttings (in Tons) | 0.02 Tons | LANDFILL | 301358 |
2014-S02 | Fracing Fluid Waste (in Barrels) | 51.86 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014-S02 | Fracing Fluid Waste (in Barrels) | 214.26 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S02 | Produced Fluid (in Barrels) | 275.05 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2014-S02 | Produced Fluid (in Barrels) | 1,516.79 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S01 | Fracing Fluid Waste (in Barrels) | 74.84 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S01 | Produced Fluid (in Barrels) | 183.37 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015-S01 | Produced Fluid (in Barrels) | 1,029.91 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Produced Fluid (in Barrels) | 30.23 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015-S02 | Produced Fluid (in Barrels) | 500.93 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015-S02 | Produced Fluid (in Barrels) | 444.69 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 100.02 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 1,595.26 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Synthetic Liner Materials (in Tons) RWC 806 | 0.26 Tons | LANDFILL | 301358 |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | REUSE (AT WELL PAD) | |
2017-M02 | Produced Fluid (in Barrels) RWC 802 | 133.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 33.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 133.33 Bbl | REUSE (AT WELL PAD) | |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 233.33 Bbl | REUSE (AT WELL PAD) | |
2017-M04 | Waste Water Treatment Sludge (in Tons) RWC 804 | 2.06 Tons | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017-M05 | Produced Fluid (in Barrels) RWC 802 | 143.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 233.33 Bbl | REUSE (AT WELL PAD) | |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 133.33 Bbl | REUSE (AT WELL PAD) | |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 54.20 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 133.33 Bbl | REUSE (AT WELL PAD) | |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 35.03 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 16.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 116.67 Bbl | REUSE (AT WELL PAD) | |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 158.00 Bbl | REUSE (AT WELL PAD) | |
2017-M12 | Waste Water Treatment Sludge (in Tons) RWC 804 | 1.33 Tons | STORAGE PENDING DISPOSAL OR REUSE | PA-0678 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 115.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 311.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 140.92 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 146.67 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 1,198.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018-M06 | Synthetic Liner Materials (in Tons) RWC 806 | 2.20 Tons | LANDFILL | 301358 |
2018-M07 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 83.40 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 130.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 841.12 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 17.00 Bbl | REUSE (AT WELL PAD) | |
2018-M07 | Produced Fluid (in Tons) RWC 802 | 14.06 Tons | LANDFILL | 301358 |
2018-M07 | Synthetic Liner Materials (in Tons) RWC 806 | 0.95 Tons | LANDFILL | 301358 |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 50.00 Bbl | REUSE (AT WELL PAD) | |
2018-M08 | Synthetic Liner Materials (in Tons) RWC 806 | 0.77 Tons | LANDFILL | 301358 |
2018-M09 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 63.00 Bbl | REUSE (AT WELL PAD) | |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 225.00 Bbl | REUSE (AT WELL PAD) | |
2018-M09 | Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | 31.05 Tons | LANDFILL | 301358 |
2018-M09 | Synthetic Liner Materials (in Tons) RWC 806 | 2.81 Tons | LANDFILL | 301358 |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 126.00 Bbl | REUSE (AT WELL PAD) | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 40.00 Bbl | REUSE (AT WELL PAD) | |
2018-M11 | Synthetic Liner Materials (in Tons) RWC 806 | 0.99 Tons | LANDFILL | 301358 |
2018-M12 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 64.80 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 71.00 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Synthetic Liner Materials (in Tons) RWC 806 | 0.54 Tons | LANDFILL | 301358 |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 497.80 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 227.33 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 70.00 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Synthetic Liner Materials (in Tons) RWC 806 | 6.88 Tons | LANDFILL | 301358 |
2019-M03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 231.60 Bbl | REUSE (AT WELL PAD) | |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 154.40 Bbl | REUSE (AT WELL PAD) | |
2019-M03 | Synthetic Liner Materials (in Tons) RWC 806 | 3.71 Tons | LANDFILL | 301358 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2118703 | Primary Facility | 2012-11-19 | Routine/Complete Inspection | Violation(s) Noted | the 1-6H wells on the pad were spud without electronic notification or pre-operational inspection |
2128612 | Primary Facility | 2013-01-02 | Routine/Complete Inspection | No Violations Noted | |
2182245 | Primary Facility | 2013-07-10 | Routine/Complete Inspection | No Violations Noted | |
2194641 | Primary Facility | 2013-08-07 | Incident- Response to Accident or Event | Violation(s) Noted | 8/3/13 spill of 5 bbls of produced water from hole in coil tubing unit. Spill to containment and pad, particularly north side. Holes in liner. TLT |
2207574 | Primary Facility | 2013-09-25 | Follow-up Inspection | Outstanding Violations - Viols Req'd | Release of flowback/produced fluids from containment to well pad and rock-lined ditch. TLT |
2215560 | Primary Facility | 2013-10-22 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | 8/7/13 Viols corrected. 9/25/13 viols remain outstanding. TLT |
2230609 | Primary Facility | 2013-12-18 | Compliance Evaluation | No Violations Noted | Site remediated, summary report submitted. TLT |
2265736 | Primary Facility | 2014-04-23 | Routine/Complete Inspection | No Violations Noted | |
2361294 | Primary Facility | 2015-04-15 | Routine/Complete Inspection | No Violations Noted | Temporary stabilization generally >70% cover. Temp BMPs in place. One filter sock near access road entrance needs repair. Elevated conductivity in sediment/infiltration basin on north side of pad (2.3 mS/cm). Several stained spots on pad surface. |
2363488 | Primary Facility | 2015-04-08 | Administrative/File Review | No Violations Noted | The Department has reviewed the Remedial Action Plan Completion Report for the removal of the high conductivity pad material at the above-referenced well pad that occurred on December 20, 2014. The report for the release was prepared by SWEPI LP and received by the Department on March 10, 2015. |
2496422 | Primary Facility | 2016-06-27 | Routine/Complete Inspection | No Violations Noted | Routine inspection to assess overall site conditions. No SWEPI representatives were present.
Vegetative cover on site is greater than 70%. No evidence of accelerated erosion or sedimentation was observed. Per § 3216(c) of the 2012 Oil and Gas Act (58 Pa.C.S. §3216(c)), site restoration is required to occur within 9 months of completion of well drilling, unless an extension request is filed with, and approved by the Department. A restoration extension request was approved by the Department on 04/09/2015, which extends the restoration deadline until 04/09/2017. No violations were cited during this inspection. |
2543584 | Primary Facility | 2016-12-08 | Routine/Complete Inspection | No Violations Noted | Routine inspection to assess overall site conditions. No SWEPI representatives were present.
Vegetative cover on site is greater than 70%. Temporary erosion and sediment control BMPs have been removed. No evidence of accelerated erosion or sedimentation was observed. A restoration extension request was approved by the Department on 04/09/2015, which extends the restoration deadline until 04/09/2017. The Erosion and Sediment Control General Permit for the site expires on 05/01/2017. No violations were cited during this inspection. |
2717059 | Primary Facility | 2018-04-11 | Routine/Complete Inspection | No Violations Noted | Weather was 33° and sunny at time of inspection. Thrre were no Rockdale representatives on location at time of inspection. Well had one analog pressure gauge attached above the swab valve and one analog pressure gauge attached to the 5 1/2 inch casing. The pressure gauge attached above the swab valve read approximately 740 psi and the gauge attached to the casing read approximately 250 psi at time of inspection. There were three annulus vents plumbed to surface. Unable to determine the origin point of each individual annulus vent due to the cellar being full of gravel. Annulus vents were 2", 1 1/2" and 1". No combustible gas was detected at time of inspection. No violations noted at time of inspection. |
2732016 | Primary Facility | 2018-05-14 | Routine/Complete Inspection | No Violations Noted | At the time of the inspection; containment, tanks, and equipment were installed in anticipation of completions activities on several of the wells onsite. PCSM/Site Restoration plans have been partially implemented. Infiltration basins have been installed but the impervious gravel pad surface has not been reduced as depicted in the approved plans. A 2-year extension on site restoration was approved on 10/20/2017. The Department recommends the PCSM/Site Restoration plans be implemented as permitted by 10/20/2019 or modified to account for the impervious pad surface. |
2738628 | Primary Facility | 2018-06-05 | Routine/Complete Inspection | No Violations Noted | I met Luke Chesner and Levi Lee of Rockdale when I arrived. Coil tubing rig on location drilling out plugs on the 6H prior to moving to the 4H. I noted two areas on the pad that were wet and muddy, one between the coil tubing rig and a pump truck (approximately 5-8 gallons of free water and 30' x 40'), and one between two Baker tank batteries (approximately 10-15 gallons of free water and 30' x 50'). Conductance reading in the former was 9.22 mS/cm, and was over the limit of my meter (19.99mS/cm) in the latter. I pointed both of these areas out to Luke and Levi, and took a grab sample (ID#0939066) from a puddle in the area between the Baker tank batteries. Luke and Levi had a vac truck working in the area between the pump truck and the coil tubing rig almost immediately, and I recommended that they vac the area between the Baker tank batteries and start to remove the affected soil ASAP. The elevated conductance in these areas is an indication of a potential release of produced water or flowback to the |
2761125 | Primary Facility | 2018-08-06 | Incident- Response to Accident or Event | No Violations Noted | I arrived on site in response to a spill notification from Rockdale called in at 09:45 on 8/4/18. Regina Logue of Rockdale reported that approximately 2 barrels of potentially contaminated rainwater was released to the pad due to a failed containment, and stated that the release was near the aboveground storage tank. The only person present at the pad when I arrived was Brady Bryington of Principal Enterprise. He pointed out the area of the release, and when I inquired informed me that the AST contained fresh water. I screened the release area, which was at the corner of an upright tank containment, with my soil conductance meter; most readings were in the range of .10-2.2 mS/cm, and the readings dropped dramatically when I pushed the meter 1/4" into the soil. I did locate a spot that seemed to be somewhat removed from the spill area near the center of the upright tank containment that was over limit on my soil meter (greater than 4.0 mS/cm). Towards the rock-lined ditch from the release area, soil con |
2791178 | Primary Facility | 2018-10-17 | Routine/Partial Inspection | No Violations Noted | No activity on site. Due to time constraints, only a partial inspection was performed. Site had a large puddle (50-100 gallons) present in the area of the release documented in the 6/5/18 inspection. Soil conductance readings in this area ranged from .20-.53 mS/cm. Violations remain outstanding. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2118703 | 654540 | 11/19/2012 | 2012-11-19 | 201F - Failure to notify DEP, landowner, political subdivision, or coal owner 24 hrs prior to commencement of drilling | Administrative | the 1-6H wells on the pad were spud without electronic notification or pre-operational inspection |
2118703 | 654541 | 11/19/2012 | 2012-11-19 | 201E - Failure to comply with terms and conditions of permit | Environmental Health & Safety | the 1-6H wells on the pad were spud without electronic notification or pre-operational inspection |
2194641 | 674910 | 08/07/2013 | 2013-08-07 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | 78.54 for failure to control pollutional substance (produced water). Release of approximately 5 bbls of fluid to pad surface. TLT |
2194641 | 674911 | 08/07/2013 | 2013-08-07 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | 691.402 CSL for allowing an unpermitted discharge with the potential to pollute Waters of the Commonwealth. Approximately 5 bbls of produced water released to pad adjacent to sediment trap. TLT |
2194641 | 674912 | 08/07/2013 | 2013-08-07 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | 6018.301 SWMA for an unpermitted discharge of residual waste onto the ground. Approximately 5 bbls of produced water released to pad surface. TLT |
2207574 | 679028 | 09/25/2013 | 2013-09-25 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | 78.54. Tank leaked flowback/produced fluids into containment. The containment leaked the fluid onto the ground and into a rock-lined ditch. TLT |
2207574 | 679029 | 09/25/2013 | 2013-09-25 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | 691.402 CSL. Release of flowback/produced fluids from containment onto the ground and into a rock-lined ditch. TLT |
2207574 | 679030 | 09/25/2013 | 2013-09-25 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | 6018.301 SWMA. Containment leaked flowback/produced fluids onto the ground and into a rock-lined ditch. TLT |
2207574 | 679031 | 09/25/2013 | 2013-09-25 | 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | Administrative | Actual citation is Title 58, Section 3218.2(a)(2) - Containment for Unconventional Wells. Operator failed to construct containment to prevent spills to the ground surface. Containment was not sufficiently impervious to contain spilled material. TLT |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
654540 | 291063 | NOV - Notice of Violation | Comply/Closed | 2014-11-12 | |||
654541 | 291063 | NOV - Notice of Violation | Comply/Closed | 2014-11-12 | |||
674910 | 300788 | NOV - Notice of Violation | Comply/Closed | 2013-10-25 | |||
674911 | 300788 | NOV - Notice of Violation | Comply/Closed | 2013-10-25 | |||
674912 | 300788 | NOV - Notice of Violation | Comply/Closed | 2013-10-25 | |||
679028 | 302817 | NOV - Notice of Violation | Comply/Closed | 2013-12-19 | |||
679029 | 302817 | NOV - Notice of Violation | Comply/Closed | 2013-12-19 | |||
679030 | 302817 | NOV - Notice of Violation | Comply/Closed | 2013-12-19 | |||
679031 | 302817 | NOV - Notice of Violation | Comply/Closed | 2013-12-19 |
For data sources see[7]