X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-125-24819"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-125-24819
 
| Well ID: 37-125-24819
| style="height=100%; align=center" rowspan="14" | {{#display_map: 40.059153, -80.311422 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.059153, -80.311422 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 21: Line 21:
 
| License Status: Active
 
| License Status: Active
 
|-
 
|-
| Spud Date: 12/05/2012
+
| Spud Date: 2012-12-05
 
|-
 
|-
| Permit Date: 8/15/2012
+
| Permit Date: 2012-08-15
 
|-
 
|-
 
| Unconventional Well: Y
 
| Unconventional Well: Y
Line 49: Line 49:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2014-09-17
 +
| 2014-10-04
 +
| style="text-align: right;" | 7287
 +
| style="text-align: right;" | 9,999,880.0
 +
| style="text-align: right;" | 0
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="31"| 1
 +
|- valign="top"
 +
| rowspan="30"| Sand (Proppant), DAP-903, DWP-111,<br/> DWP-614, DWP-901, BioClear<br/> 2000, DWP-NE1, Spearhead Acid
 +
| rowspan="30"| CWS
 +
| rowspan="30"| Propping Agent, Scale Inhibitor, Gel Slurry, Viscosifier, Breaker, Biocide, Non-Emulsifier, Clean Perforations
 +
| Crystalline silica (Quartz)
 +
| 14808-60-7
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 10.4146
 +
| style="text-align: right;" | 9,773,350.0
 +
|-
 +
| Propargyl Alcohol
 +
| 107-19-7
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.0006
 +
| style="text-align: right;" | 558.48
 +
|-
 +
| Illite
 +
| 12173-60-3
 +
| style="text-align: right;" | 1
 +
| style="text-align: right;" | 0.00867
 +
| style="text-align: right;" | 8137.68
 +
|-
 +
| Distillates (petroleum), hydrotreated middle
 +
| 64742-46-7
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.0334
 +
| style="text-align: right;" | 31339.5
 +
|-
 +
| Calcite
 +
| 471-34-1
 +
| style="text-align: right;" | 1
 +
| style="text-align: right;" | 0.01523
 +
| style="text-align: right;" | 14292.3
 +
|-
 +
| Alkenes, C>10 a-
 +
| 64743-02-8
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00179
 +
| style="text-align: right;" | 1675.43
 +
|-
 +
| Sorbitan monooleate
 +
| 1338-43-8
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00553
 +
| style="text-align: right;" | 5187.21
 +
|-
 +
| 2,2-Dibromo-3-Nitrilopropionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 20
 +
| style="text-align: right;" | 0.01246
 +
| style="text-align: right;" | 11696.4
 +
|-
 +
| 2-Propenoic acid, polymer with 2-propenamide, sodium salt
 +
| 25987-30-8
 +
| style="text-align: right;" | 40
 +
| style="text-align: right;" | 0.04422
 +
| style="text-align: right;" | 41497.7
 +
|-
 +
| Sodium chloride
 +
| 7647-14-5
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00006000
 +
| style="text-align: right;" | 55.85
 +
|-
 +
| Formaldehyde
 +
| 50-00-0
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00012
 +
| style="text-align: right;" | 111.7
 +
|-
 +
| 2-Propenoic acid, polymer with sodium phosphonate
 +
| 71050-62-9
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.00624
 +
| style="text-align: right;" | 5856.93
 +
|-
 +
| Ammonium Persulfate
 +
| 7727-54-0
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 0.00001000
 +
| style="text-align: right;" | 10
 +
|-
 +
| Modified thiourea polymer
 +
| 68527-49-1
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00179
 +
| style="text-align: right;" | 1675.43
 +
|-
 +
| Polyethylene glycol mixture
 +
| 25322-68-3
 +
| style="text-align: right;" | 70
 +
| style="text-align: right;" | 0.01246
 +
| style="text-align: right;" | 11696.4
 +
|-
 +
| Isopropanol
 +
| 67-63-0
 +
| style="text-align: right;" | 40
 +
| style="text-align: right;" | 0.01528
 +
| style="text-align: right;" | 14336.5
 +
|-
 +
| Alcohols, C14-15, ethoxylated
 +
| 68951-67-7
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00179
 +
| style="text-align: right;" | 1675.43
 +
|-
 +
| Guar gum
 +
| 9000-30-0
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.00023
 +
| style="text-align: right;" | 216.24
 +
|-
 +
| Oxirane, 2-methyl-, polymer with oxirane, monodecyl ether
 +
| 37251-67-5
 +
| style="text-align: right;" | 1.5
 +
| style="text-align: right;" | 0.00001000
 +
| style="text-align: right;" | 5.41
 +
|-
 +
| Quaternary ammonium compounds,<br/> bis(hydrogenated tallow alkyl)dimethyl,<br/> salts with bentonite
 +
| 68953-58-2
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00002000
 +
| style="text-align: right;" | 18.02
 +
|-
 +
| Ilmenite
 +
| 98072-94-7
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00321
 +
| style="text-align: right;" | 3013.95
 +
|-
 +
| Diallyldimethylammonium chloride
 +
| 7398-69-8
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00191
 +
| style="text-align: right;" | 1792.06
 +
|-
 +
| Dimethylcocoamine, bis(chloroethyl)<br/> ether, diquaternary ammonium salt
 +
| 68607-28-3
 +
| style="text-align: right;" | 40
 +
| style="text-align: right;" | 0.01528
 +
| style="text-align: right;" | 14336.5
 +
|-
 +
| Goethite
 +
| 1310-14-1
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00539
 +
| style="text-align: right;" | 5055.71
 +
|-
 +
| Fatty acids, tall-oil
 +
| 61790-12-3
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00179
 +
| style="text-align: right;" | 1675.43
 +
|-
 +
| Methanol
 +
| 67-56-1
 +
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 0.0093
 +
| style="text-align: right;" | 8727.03
 +
|-
 +
| Apatite
 +
| 64476-38-6
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00394
 +
| style="text-align: right;" | 3694.54
 +
|-
 +
| Biotite
 +
| 1302-27-8
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00394
 +
| style="text-align: right;" | 3694.54
 +
|-
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 37
 +
| style="text-align: right;" | 0.42033
 +
| style="text-align: right;" | 394452
 +
|-
 +
| Poly(oxyethylene)nonylphenol ether
 +
| 9016-45-9
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00553
 +
| style="text-align: right;" | 5187.21
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Water
 +
| rowspan="1"| Customer & CWS
 +
| rowspan="1"| Base Fluid & Mix Water
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 88.9549
 +
| style="text-align: right;" | 83,477,600.0
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 147: Line 379:
 
!scope="col" | Waste Facility ID
 
!scope="col" | Waste Facility ID
 
|-
 
|-
| 15AUGU
+
| 2013-S01
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,716.02 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 15DECU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,053.83 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 15JULU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,451.92 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 15NOVU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,181.17 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 15OCTU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,444.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 15SEPU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,473.80 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16APRU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,308.27 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16AUGU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 800.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16DECU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 353.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16FEBU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 890.50 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16JANU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,076.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16JULU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 808.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16JUNU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.50 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-013-20609
 
|-
 
| 16JUNU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 199.44 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-119-28803
 
|-
 
| 16JUNU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 530.06 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16MARU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 778.75 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16MAYU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 11.70 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-119-28780
 
|-
 
| 16MAYU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 44.80 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-119-28803
 
|-
 
| 16MAYU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 896.91 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16NOVU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 36.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-013-20609
 
|-
 
| 16NOVU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 12.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-119-28780
 
|-
 
| 16NOVU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 150.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-119-28803
 
|-
 
| 16NOVU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 365.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16OCTU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 165.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-013-20609
 
|-
 
| 16OCTU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 60.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-119-28780
 
|-
 
| 16OCTU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 290.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-119-28803
 
|-
 
| 16OCTU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 197.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16SEPU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 751.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2013-1
 
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 42.26 Tons
 
| style="text-align: right;" | 42.26 Tons
Line 321: Line 385:
 
| 100172
 
| 100172
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 675.78 Tons
 
| style="text-align: right;" | 675.78 Tons
Line 327: Line 391:
 
| PAD059087072
 
| PAD059087072
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Drilling Fluid Waste (in Barrels)
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align: right;" | 43.89 Bbl
 
| style="text-align: right;" | 43.89 Bbl
Line 333: Line 397:
 
| 301071
 
| 301071
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 180.02 Tons
 
| style="text-align: right;" | 180.02 Tons
Line 339: Line 403:
 
| PAD059087072
 
| PAD059087072
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 391.77 Tons
 
| style="text-align: right;" | 391.77 Tons
Line 345: Line 409:
 
| 301071
 
| 301071
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Drilling Fluid Waste (in Barrels)
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align: right;" | 0.15 Bbl
 
| style="text-align: right;" | 0.15 Bbl
Line 351: Line 415:
 
| 301071
 
| 301071
 
|-
 
|-
| 2014-2
+
| 2014-S02
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 2,719.00 Bbl
 
| style="text-align: right;" | 2,719.00 Bbl
Line 357: Line 421:
 
|  
 
|  
 
|-
 
|-
| 2015-07
+
| 2015-M07
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,451.92 Bbl
 
| style="text-align: right;" | 1,451.92 Bbl
Line 363: Line 427:
 
|  
 
|  
 
|-
 
|-
| 2015-08
+
| 2015-M08
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,716.02 Bbl
 
| style="text-align: right;" | 1,716.02 Bbl
Line 369: Line 433:
 
|  
 
|  
 
|-
 
|-
| 2015-09
+
| 2015-M09
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,473.80 Bbl
 
| style="text-align: right;" | 1,473.80 Bbl
Line 375: Line 439:
 
|  
 
|  
 
|-
 
|-
| 2015-1
+
| 2015-M10
| Fracturing Fluid Waste (in Tons)
 
| style="text-align: right;" | 46.06 Tons
 
| LANDFILL
 
| 100172
 
|-
 
| 2015-1
 
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 5,191.40 Bbl
+
| style="text-align: right;" | 1,444.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2015-10
+
| 2015-M11
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 1,444.00 Bbl
+
| style="text-align: right;" | 1,181.17 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2015-11
+
| 2015-M12
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 1,181.17 Bbl
+
| style="text-align: right;" | 1,053.83 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2015-12
+
| 2015-S01
 +
| Fracturing Fluid Waste (in Tons)
 +
| style="text-align: right;" | 46.06 Tons
 +
| LANDFILL
 +
| 100172
 +
|-
 +
| 2015-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 1,053.83 Bbl
+
| style="text-align: right;" | 5,191.40 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2016-01
+
| 2016-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,076.00 Bbl
 
| style="text-align: right;" | 1,076.00 Bbl
Line 411: Line 475:
 
|  
 
|  
 
|-
 
|-
| 2016-02
+
| 2016-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 890.50 Bbl
 
| style="text-align: right;" | 890.50 Bbl
Line 417: Line 481:
 
|  
 
|  
 
|-
 
|-
| 2016-03
+
| 2016-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 778.75 Bbl
 
| style="text-align: right;" | 778.75 Bbl
Line 423: Line 487:
 
|  
 
|  
 
|-
 
|-
| 2016-04
+
| 2016-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,308.27 Bbl
 
| style="text-align: right;" | 1,308.27 Bbl
Line 429: Line 493:
 
|  
 
|  
 
|-
 
|-
| 2016-05
+
| 2016-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 11.70 Bbl
 
| style="text-align: right;" | 11.70 Bbl
Line 435: Line 499:
 
| 34-119-28780
 
| 34-119-28780
 
|-
 
|-
| 2016-05
+
| 2016-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 44.80 Bbl
 
| style="text-align: right;" | 44.80 Bbl
Line 441: Line 505:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2016-05
+
| 2016-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 896.91 Bbl
 
| style="text-align: right;" | 896.91 Bbl
Line 447: Line 511:
 
|  
 
|  
 
|-
 
|-
| 2016-06
+
| 2016-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.50 Bbl
 
| style="text-align: right;" | 100.50 Bbl
Line 453: Line 517:
 
| 34-013-20609
 
| 34-013-20609
 
|-
 
|-
| 2016-06
+
| 2016-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 199.44 Bbl
 
| style="text-align: right;" | 199.44 Bbl
Line 459: Line 523:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2016-06
+
| 2016-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 530.06 Bbl
 
| style="text-align: right;" | 530.06 Bbl
Line 465: Line 529:
 
|  
 
|  
 
|-
 
|-
| 2016-07
+
| 2016-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 808.00 Bbl
 
| style="text-align: right;" | 808.00 Bbl
Line 471: Line 535:
 
|  
 
|  
 
|-
 
|-
| 2016-08
+
| 2016-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 800.00 Bbl
 
| style="text-align: right;" | 800.00 Bbl
Line 477: Line 541:
 
|  
 
|  
 
|-
 
|-
| 2016-09
+
| 2016-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 751.00 Bbl
 
| style="text-align: right;" | 751.00 Bbl
Line 483: Line 547:
 
|  
 
|  
 
|-
 
|-
| 2016-10
+
| 2016-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 165.00 Bbl
 
| style="text-align: right;" | 165.00 Bbl
Line 489: Line 553:
 
| 34-013-20609
 
| 34-013-20609
 
|-
 
|-
| 2016-10
+
| 2016-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 60.00 Bbl
 
| style="text-align: right;" | 60.00 Bbl
Line 495: Line 559:
 
| 34-119-28780
 
| 34-119-28780
 
|-
 
|-
| 2016-10
+
| 2016-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 290.00 Bbl
 
| style="text-align: right;" | 290.00 Bbl
Line 501: Line 565:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2016-10
+
| 2016-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 197.00 Bbl
 
| style="text-align: right;" | 197.00 Bbl
Line 507: Line 571:
 
|  
 
|  
 
|-
 
|-
| 2016-11
+
| 2016-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 36.00 Bbl
 
| style="text-align: right;" | 36.00 Bbl
Line 513: Line 577:
 
| 34-013-20609
 
| 34-013-20609
 
|-
 
|-
| 2016-11
+
| 2016-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 12.00 Bbl
 
| style="text-align: right;" | 12.00 Bbl
Line 519: Line 583:
 
| 34-119-28780
 
| 34-119-28780
 
|-
 
|-
| 2016-11
+
| 2016-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 150.00 Bbl
 
| style="text-align: right;" | 150.00 Bbl
Line 525: Line 589:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2016-11
+
| 2016-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 365.00 Bbl
 
| style="text-align: right;" | 365.00 Bbl
Line 531: Line 595:
 
|  
 
|  
 
|-
 
|-
| 2016-12
+
| 2016-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 353.00 Bbl
 
| style="text-align: right;" | 353.00 Bbl
Line 537: Line 601:
 
|  
 
|  
 
|-
 
|-
| 2017-01
+
| 2017-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,262.63 Bbl
 
| style="text-align: right;" | 1,262.63 Bbl
Line 543: Line 607:
 
|  
 
|  
 
|-
 
|-
| 2017-02
+
| 2017-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,155.10 Bbl
 
| style="text-align: right;" | 1,155.10 Bbl
Line 549: Line 613:
 
|  
 
|  
 
|-
 
|-
| 2017-05
+
| 2017-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,208.00 Bbl
 
| style="text-align: right;" | 1,208.00 Bbl
Line 555: Line 619:
 
|  
 
|  
 
|-
 
|-
| 2017-06
+
| 2017-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,269.00 Bbl
 
| style="text-align: right;" | 1,269.00 Bbl
Line 561: Line 625:
 
|  
 
|  
 
|-
 
|-
| 2017-07
+
| 2017-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,034.00 Bbl
 
| style="text-align: right;" | 1,034.00 Bbl
Line 567: Line 631:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2017-08
+
| 2017-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 702.00 Bbl
 
| style="text-align: right;" | 702.00 Bbl
Line 573: Line 637:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2017-09
+
| 2017-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 411.00 Bbl
 
| style="text-align: right;" | 411.00 Bbl
Line 579: Line 643:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2017-10
+
| 2017-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 346.00 Bbl
 
| style="text-align: right;" | 346.00 Bbl
Line 585: Line 649:
 
|  
 
|  
 
|-
 
|-
| 2017-11
+
| 2017-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 495.00 Bbl
 
| style="text-align: right;" | 495.00 Bbl
Line 591: Line 655:
 
|  
 
|  
 
|-
 
|-
| 2017-12
+
| 2017-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 471.00 Bbl
 
| style="text-align: right;" | 471.00 Bbl
Line 597: Line 661:
 
|  
 
|  
 
|-
 
|-
| 2018-01
+
| 2018-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 917.00 Bbl
 
| style="text-align: right;" | 917.00 Bbl
Line 603: Line 667:
 
|  
 
|  
 
|-
 
|-
| 2018-02
+
| 2018-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 871.00 Bbl
 
| style="text-align: right;" | 871.00 Bbl
Line 609: Line 673:
 
|  
 
|  
 
|-
 
|-
| 2018-03
+
| 2018-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 970.00 Bbl
 
| style="text-align: right;" | 970.00 Bbl
Line 615: Line 679:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2018-04
+
| 2018-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 854.00 Bbl
 
| style="text-align: right;" | 854.00 Bbl
Line 621: Line 685:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2018-05
+
| 2018-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 906.00 Bbl
 
| style="text-align: right;" | 906.00 Bbl
Line 627: Line 691:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2018-06
+
| 2018-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 890.00 Bbl
 
| style="text-align: right;" | 890.00 Bbl
Line 633: Line 697:
 
|  
 
|  
 
|-
 
|-
| 2018-07
+
| 2018-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 891.00 Bbl
 
| style="text-align: right;" | 891.00 Bbl
Line 639: Line 703:
 
|  
 
|  
 
|-
 
|-
| 2018-08
+
| 2018-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,846.00 Bbl
 
| style="text-align: right;" | 1,846.00 Bbl
Line 645: Line 709:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2018-09
+
| 2018-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,839.00 Bbl
 
| style="text-align: right;" | 1,839.00 Bbl
Line 651: Line 715:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2018-10
+
| 2018-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,849.00 Bbl
 
| style="text-align: right;" | 1,849.00 Bbl
Line 657: Line 721:
 
|  
 
|  
 
|-
 
|-
| 2018-11
+
| 2018-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,849.00 Bbl
 
| style="text-align: right;" | 1,849.00 Bbl
Line 663: Line 727:
 
|  
 
|  
 
|-
 
|-
| 2018-12
+
| 2018-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,782.00 Bbl
 
| style="text-align: right;" | 1,782.00 Bbl
Line 669: Line 733:
 
|  
 
|  
 
|-
 
|-
| 2019-01
+
| 2019-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,910.00 Bbl
 
| style="text-align: right;" | 1,910.00 Bbl
Line 675: Line 739:
 
|  
 
|  
 
|-
 
|-
| 2019-02
+
| 2019-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,716.00 Bbl
 
| style="text-align: right;" | 1,716.00 Bbl
Line 681: Line 745:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2019-03
+
| 2019-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 501.00 Bbl
 
| style="text-align: right;" | 501.00 Bbl
Line 706: Line 770:
 
| 2129806
 
| 2129806
 
| Primary Facility
 
| Primary Facility
| 01/09/2013
+
| 2013-01-09
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 713: Line 777:
 
| 2252022
 
| 2252022
 
| Primary Facility
 
| Primary Facility
| 02/28/2014
+
| 2014-02-28
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 720: Line 784:
 
| 2422784
 
| 2422784
 
| Primary Facility
 
| Primary Facility
| 10/28/2015
+
| 2015-10-28
 
| Site Restoration
 
| Site Restoration
 
| No Violations Noted
 
| No Violations Noted
Line 773: Line 837:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
== Fracking Activities ==
 
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Job Start Date
 
!scope="col" | Job End Date
 
!scope="col" | True Vertical Depth (ft)
 
!scope="col" | Total Water Volume (gal)
 
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
| 1
 
| 09/17/2014
 
| 10/04/2014
 
| style="text-align: right;" | 7287
 
| style="text-align: right;" | 9,999,880.0
 
| style="text-align: right;" | 0
 
|-
 
|}
 
==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Trade Name
 
!scope="col" | Supplier
 
!scope="col" | Purpose
 
!scope="col" | Ingredient Name
 
!scope="col" | CAS Number
 
!scope="col" | Additive Percentage by Mass
 
!scope="col" | Job Percentage by Mass
 
!scope="col" | Mass Used (lb)
 
|-
 
|- valign="top"
 
| rowspan="31"| 1
 
| rowspan="30"| Sand (Proppant), DAP-903, DWP-111, DWP-614, DWP-901, BioClear 2000, DWP-NE1, Spearhead Acid
 
| rowspan="30"| CWS
 
| rowspan="30"| Propping Agent, Scale Inhibitor, Gel Slurry, Viscosifier, Breaker, Biocide, Non-Emulsifier, Clean Perforations
 
| Crystalline silica (Quartz)
 
| 14808-60-7
 
| style="text-align: right;" | 100
 
| style="text-align: right;" | 10.4146
 
| style="text-align: right;" | 9,773,350.0
 
|-
 
| Propargyl Alcohol
 
| 107-19-7
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.0006
 
| style="text-align: right;" | 558.48
 
|-
 
| Illite
 
| 12173-60-3
 
| style="text-align: right;" | 1
 
| style="text-align: right;" | 0.00867
 
| style="text-align: right;" | 8137.68
 
|-
 
| Distillates (petroleum), hydrotreated middle
 
| 64742-46-7
 
| style="text-align: right;" | 60
 
| style="text-align: right;" | 0.0334
 
| style="text-align: right;" | 31339.5
 
|-
 
| Calcite
 
| 471-34-1
 
| style="text-align: right;" | 1
 
| style="text-align: right;" | 0.01523
 
| style="text-align: right;" | 14292.3
 
|-
 
| Alkenes, C>10 a-
 
| 64743-02-8
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.00179
 
| style="text-align: right;" | 1675.43
 
|-
 
| Sorbitan monooleate
 
| 1338-43-8
 
| style="text-align: right;" | 5
 
| style="text-align: right;" | 0.00553
 
| style="text-align: right;" | 5187.21
 
|-
 
| 2,2-Dibromo-3-Nitrilopropionamide
 
| 10222-01-2
 
| style="text-align: right;" | 20
 
| style="text-align: right;" | 0.01246
 
| style="text-align: right;" | 11696.4
 
|-
 
| 2-Propenoic acid, polymer with 2-propenamide, sodium salt
 
| 25987-30-8
 
| style="text-align: right;" | 40
 
| style="text-align: right;" | 0.04422
 
| style="text-align: right;" | 41497.7
 
|-
 
| Sodium chloride
 
| 7647-14-5
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.00006000
 
| style="text-align: right;" | 55.85
 
|-
 
| Formaldehyde
 
| 50-00-0
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.00012
 
| style="text-align: right;" | 111.7
 
|-
 
| 2-Propenoic acid, polymer with sodium phosphonate
 
| 71050-62-9
 
| style="text-align: right;" | 60
 
| style="text-align: right;" | 0.00624
 
| style="text-align: right;" | 5856.93
 
|-
 
| Ammonium Persulfate
 
| 7727-54-0
 
| style="text-align: right;" | 100
 
| style="text-align: right;" | 0.00001000
 
| style="text-align: right;" | 10
 
|-
 
| Modified thiourea polymer
 
| 68527-49-1
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.00179
 
| style="text-align: right;" | 1675.43
 
|-
 
| Polyethylene glycol mixture
 
| 25322-68-3
 
| style="text-align: right;" | 70
 
| style="text-align: right;" | 0.01246
 
| style="text-align: right;" | 11696.4
 
|-
 
| Isopropanol
 
| 67-63-0
 
| style="text-align: right;" | 40
 
| style="text-align: right;" | 0.01528
 
| style="text-align: right;" | 14336.5
 
|-
 
| Alcohols, C14-15, ethoxylated
 
| 68951-67-7
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.00179
 
| style="text-align: right;" | 1675.43
 
|-
 
| Guar gum
 
| 9000-30-0
 
| style="text-align: right;" | 60
 
| style="text-align: right;" | 0.00023
 
| style="text-align: right;" | 216.24
 
|-
 
| Oxirane, 2-methyl-, polymer with oxirane, monodecyl ether
 
| 37251-67-5
 
| style="text-align: right;" | 1.5
 
| style="text-align: right;" | 0.00001000
 
| style="text-align: right;" | 5.41
 
|-
 
| Quaternary ammonium compounds, bis(hydrogenated tallow alkyl)dimethyl, salts with bentonite
 
| 68953-58-2
 
| style="text-align: right;" | 5
 
| style="text-align: right;" | 0.00002000
 
| style="text-align: right;" | 18.02
 
|-
 
| Ilmenite
 
| 98072-94-7
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.00321
 
| style="text-align: right;" | 3013.95
 
|-
 
| Diallyldimethylammonium chloride
 
| 7398-69-8
 
| style="text-align: right;" | 5
 
| style="text-align: right;" | 0.00191
 
| style="text-align: right;" | 1792.06
 
|-
 
| Dimethylcocoamine, bis(chloroethyl) ether, diquaternary ammonium salt
 
| 68607-28-3
 
| style="text-align: right;" | 40
 
| style="text-align: right;" | 0.01528
 
| style="text-align: right;" | 14336.5
 
|-
 
| Goethite
 
| 1310-14-1
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.00539
 
| style="text-align: right;" | 5055.71
 
|-
 
| Fatty acids, tall-oil
 
| 61790-12-3
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.00179
 
| style="text-align: right;" | 1675.43
 
|-
 
| Methanol
 
| 67-56-1
 
| style="text-align: right;" | 15
 
| style="text-align: right;" | 0.0093
 
| style="text-align: right;" | 8727.03
 
|-
 
| Apatite
 
| 64476-38-6
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.00394
 
| style="text-align: right;" | 3694.54
 
|-
 
| Biotite
 
| 1302-27-8
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.00394
 
| style="text-align: right;" | 3694.54
 
|-
 
| Hydrochloric acid
 
| 7647-01-0
 
| style="text-align: right;" | 37
 
| style="text-align: right;" | 0.42033
 
| style="text-align: right;" | 394452
 
|-
 
| Poly(oxyethylene)nonylphenol ether
 
| 9016-45-9
 
| style="text-align: right;" | 5
 
| style="text-align: right;" | 0.00553
 
| style="text-align: right;" | 5187.21
 
|-
 
|- valign="top"
 
| rowspan="1"| Water
 
| rowspan="1"| Customer & CWS
 
| rowspan="1"| Base Fluid & Mix Water
 
| Water
 
| 7732-18-5
 
| style="text-align: right;" | 100
 
| style="text-align: right;" | 88.9549
 
| style="text-align: right;" | 83,477,600.0
 
|-
 
|}
 
For data sources see<ref>{{cite web
 
| title =FracFocus Fracking Chemicals Database
 
| date = 2019-04-02
 
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
| accessdate = 2019-06-19 }}</ref>
 
 
==References==
 
==References==
 
<references/>
 
<references/>

Revision as of 11:03, 3 August 2019

Well Details

Well ID: 37-125-24819
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Morris Township
Operator Name: HG ENERGY II APPALACHIA LLC
Well Pad ID: 148725
Farm/Lease Name: LAMPERSKI NV58DHS
License Status: Active
Spud Date: 2012-12-05
Permit Date: 2012-08-15
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 40.059153
Longitude: -80.311422

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-09-17 2014-10-04 7287 9,999,880.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1
Sand (Proppant), DAP-903, DWP-111,
DWP-614, DWP-901, BioClear
2000, DWP-NE1, Spearhead Acid
CWS Propping Agent, Scale Inhibitor, Gel Slurry, Viscosifier, Breaker, Biocide, Non-Emulsifier, Clean Perforations Crystalline silica (Quartz) 14808-60-7 100 10.4146 9,773,350.0
Propargyl Alcohol 107-19-7 0.1 0.0006 558.48
Illite 12173-60-3 1 0.00867 8137.68
Distillates (petroleum), hydrotreated middle 64742-46-7 60 0.0334 31339.5
Calcite 471-34-1 1 0.01523 14292.3
Alkenes, C>10 a- 64743-02-8 0.1 0.00179 1675.43
Sorbitan monooleate 1338-43-8 5 0.00553 5187.21
2,2-Dibromo-3-Nitrilopropionamide 10222-01-2 20 0.01246 11696.4
2-Propenoic acid, polymer with 2-propenamide, sodium salt 25987-30-8 40 0.04422 41497.7
Sodium chloride 7647-14-5 0.1 0.00006000 55.85
Formaldehyde 50-00-0 0.1 0.00012 111.7
2-Propenoic acid, polymer with sodium phosphonate 71050-62-9 60 0.00624 5856.93
Ammonium Persulfate 7727-54-0 100 0.00001000 10
Modified thiourea polymer 68527-49-1 0.1 0.00179 1675.43
Polyethylene glycol mixture 25322-68-3 70 0.01246 11696.4
Isopropanol 67-63-0 40 0.01528 14336.5
Alcohols, C14-15, ethoxylated 68951-67-7 0.1 0.00179 1675.43
Guar gum 9000-30-0 60 0.00023 216.24
Oxirane, 2-methyl-, polymer with oxirane, monodecyl ether 37251-67-5 1.5 0.00001000 5.41
Quaternary ammonium compounds,
bis(hydrogenated tallow alkyl)dimethyl,
salts with bentonite
68953-58-2 5 0.00002000 18.02
Ilmenite 98072-94-7 0.1 0.00321 3013.95
Diallyldimethylammonium chloride 7398-69-8 5 0.00191 1792.06
Dimethylcocoamine, bis(chloroethyl)
ether, diquaternary ammonium salt
68607-28-3 40 0.01528 14336.5
Goethite 1310-14-1 0.1 0.00539 5055.71
Fatty acids, tall-oil 61790-12-3 0.1 0.00179 1675.43
Methanol 67-56-1 15 0.0093 8727.03
Apatite 64476-38-6 0.1 0.00394 3694.54
Biotite 1302-27-8 0.1 0.00394 3694.54
Hydrochloric acid 7647-01-0 37 0.42033 394452
Poly(oxyethylene)nonylphenol ether 9016-45-9 5 0.00553 5187.21
Water Customer & CWS Base Fluid & Mix Water Water 7732-18-5 100 88.9549 83,477,600.0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0
2013 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0
2014 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0
2015 CNX GAS CO LLC 1,525,692.48 288 0.00 0 0.00 0
2016 CNX GAS CO LLC 2,102,229.11 366 0.00 0 0.00 0
2017 CNX GAS CO LLC 1,562,728.37 365 0.00 0 0.00 0
2018 HG ENERGY II APPALACHIA LLC 1,332,753.00 365 0.00 0 0.00 0
2019 HG ENERGY II APPALACHIA LLC 185,769.00 59 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2013-S01 Drill Cuttings (in Tons) 42.26 Tons LANDFILL 100172
2013-S01 Drill Cuttings (in Tons) 675.78 Tons LANDFILL PAD059087072
2013-S01 Drilling Fluid Waste (in Barrels) 43.89 Bbl LANDFILL 301071
2014-S01 Drill Cuttings (in Tons) 180.02 Tons LANDFILL PAD059087072
2014-S01 Drill Cuttings (in Tons) 391.77 Tons RESIDUAL WASTE TRANSFER FACILITY 301071
2014-S01 Drilling Fluid Waste (in Barrels) 0.15 Bbl RESIDUAL WASTE TRANSFER FACILITY 301071
2014-S02 Fracing Fluid Waste (in Barrels) 2,719.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-M07 Produced Fluid (in Barrels) 1,451.92 Bbl REUSE OTHER THAN ROAD SPREADING
2015-M08 Produced Fluid (in Barrels) 1,716.02 Bbl REUSE OTHER THAN ROAD SPREADING
2015-M09 Produced Fluid (in Barrels) 1,473.80 Bbl REUSE OTHER THAN ROAD SPREADING
2015-M10 Produced Fluid (in Barrels) 1,444.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-M11 Produced Fluid (in Barrels) 1,181.17 Bbl REUSE OTHER THAN ROAD SPREADING
2015-M12 Produced Fluid (in Barrels) 1,053.83 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S01 Fracturing Fluid Waste (in Tons) 46.06 Tons LANDFILL 100172
2015-S01 Produced Fluid (in Barrels) 5,191.40 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M01 Produced Fluid (in Barrels) RWC 802 1,076.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M02 Produced Fluid (in Barrels) RWC 802 890.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M03 Produced Fluid (in Barrels) RWC 802 778.75 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M04 Produced Fluid (in Barrels) RWC 802 1,308.27 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M05 Produced Fluid (in Barrels) RWC 802 11.70 Bbl INJECTION DISPOSAL WELL 34-119-28780
2016-M05 Produced Fluid (in Barrels) RWC 802 44.80 Bbl INJECTION DISPOSAL WELL 34-119-28803
2016-M05 Produced Fluid (in Barrels) RWC 802 896.91 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M06 Produced Fluid (in Barrels) RWC 802 100.50 Bbl INJECTION DISPOSAL WELL 34-013-20609
2016-M06 Produced Fluid (in Barrels) RWC 802 199.44 Bbl INJECTION DISPOSAL WELL 34-119-28803
2016-M06 Produced Fluid (in Barrels) RWC 802 530.06 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M07 Produced Fluid (in Barrels) RWC 802 808.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M08 Produced Fluid (in Barrels) RWC 802 800.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M09 Produced Fluid (in Barrels) RWC 802 751.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M10 Produced Fluid (in Barrels) RWC 802 165.00 Bbl INJECTION DISPOSAL WELL 34-013-20609
2016-M10 Produced Fluid (in Barrels) RWC 802 60.00 Bbl INJECTION DISPOSAL WELL 34-119-28780
2016-M10 Produced Fluid (in Barrels) RWC 802 290.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2016-M10 Produced Fluid (in Barrels) RWC 802 197.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M11 Produced Fluid (in Barrels) RWC 802 36.00 Bbl INJECTION DISPOSAL WELL 34-013-20609
2016-M11 Produced Fluid (in Barrels) RWC 802 12.00 Bbl INJECTION DISPOSAL WELL 34-119-28780
2016-M11 Produced Fluid (in Barrels) RWC 802 150.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2016-M11 Produced Fluid (in Barrels) RWC 802 365.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M12 Produced Fluid (in Barrels) RWC 802 353.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017-M01 Produced Fluid (in Barrels) RWC 802 1,262.63 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-M02 Produced Fluid (in Barrels) RWC 802 1,155.10 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-M05 Produced Fluid (in Barrels) RWC 802 1,208.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-M06 Produced Fluid (in Barrels) RWC 802 1,269.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-M07 Produced Fluid (in Barrels) RWC 802 1,034.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2017-M08 Produced Fluid (in Barrels) RWC 802 702.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2017-M09 Produced Fluid (in Barrels) RWC 802 411.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2017-M10 Produced Fluid (in Barrels) RWC 802 346.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-M11 Produced Fluid (in Barrels) RWC 802 495.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-M12 Produced Fluid (in Barrels) RWC 802 471.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M01 Produced Fluid (in Barrels) RWC 802 917.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M02 Produced Fluid (in Barrels) RWC 802 871.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M03 Produced Fluid (in Barrels) RWC 802 970.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2018-M04 Produced Fluid (in Barrels) RWC 802 854.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2018-M05 Produced Fluid (in Barrels) RWC 802 906.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2018-M06 Produced Fluid (in Barrels) RWC 802 890.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M07 Produced Fluid (in Barrels) RWC 802 891.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M08 Produced Fluid (in Barrels) RWC 802 1,846.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2018-M09 Produced Fluid (in Barrels) RWC 802 1,839.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2018-M10 Produced Fluid (in Barrels) RWC 802 1,849.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M11 Produced Fluid (in Barrels) RWC 802 1,849.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M12 Produced Fluid (in Barrels) RWC 802 1,782.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-M01 Produced Fluid (in Barrels) RWC 802 1,910.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-M02 Produced Fluid (in Barrels) RWC 802 1,716.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2019-M03 Produced Fluid (in Barrels) RWC 802 501.00 Bbl INJECTION DISPOSAL WELL 34-119-28803

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2129806 Primary Facility 2013-01-09 Drilling/Alteration No Violations Noted
2252022 Primary Facility 2014-02-28 Drilling/Alteration No Violations Noted
2422784 Primary Facility 2015-10-28 Site Restoration No Violations Noted
2483651 Primary Facility 2016-05-05 Incident- Response to Accident or Event In Compliance with Policy On Thursday May 5, 2016, I received notification of a release of brine water at the NV58HS Well Site located in Morris Township, Washington County. The release was discovered and reported on Wednesday May 4, 2016 and was estimated to involve approximately 30 to 35 gallons of brine water from a leaking dump valve in a GPU. The valve was repaired and the GPU and concrete slab were cleaned. The impacted gravel surrounding the concrete slab was excavated until conductivity probe readings identified unaffected material. The excavated material was placed into drums for off-site disposal. The incident has been determined to be In Compliance with Policy (ICP). No violations are being cited at this time.
2787397 Primary Facility 2018-10-05 Routine/Complete Inspection No Violations Noted On Friday October 5, 2018 I conducted a routine-complete inspection at the NV58 Well Site located in Morris Township, Greene County.

Gas well NV58DHS (125-24819) and the associated infrastructure appeared to be in good condition and functioning properly. The gas well was tagged with identification.

No violations were identified during the inspection.

For data sources see[7]

References