X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-125-24821"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-125-24821
 
| Well ID: 37-125-24821
| style="height=100%; align=center" rowspan="14" | {{#display_map: 40.059133, -80.311356 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.059133, -80.311356 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 21: Line 21:
 
| License Status: Active
 
| License Status: Active
 
|-
 
|-
| Spud Date: 12/05/2012
+
| Spud Date: 2012-12-05
 
|-
 
|-
| Permit Date: 8/15/2012
+
| Permit Date: 2012-08-15
 
|-
 
|-
 
| Unconventional Well: Y
 
| Unconventional Well: Y
Line 49: Line 49:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2014-10-04
 +
| 2014-10-18
 +
| style="text-align: right;" | 7312
 +
| style="text-align: right;" | 11,093,500.0
 +
| style="text-align: right;" | 0
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="27"| 1
 +
| rowspan="1"| Water
 +
| rowspan="1"| Customer & CWS
 +
| rowspan="1"| Base Fluid & Mix Water
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 87.7167
 +
| style="text-align: right;" | 92,598,900.0
 +
|-
 +
|- valign="top"
 +
| rowspan="26"| Sand (Proppant), DAP-903, DWP-614,<br/> BioClear 2000, DWP-NE1, Spearhead Acid
 +
| rowspan="26"| CWS
 +
| rowspan="26"| Propping Agent, Scale Inhibitor, Viscosifier, Biocide, Non-Emulsifier, Clean Perforations
 +
| Apatite
 +
| 64476-38-6
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00326
 +
| style="text-align: right;" | 3440.82
 +
|-
 +
| Distillates (petroleum), hydrotreated middle
 +
| 64742-46-7
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.03225
 +
| style="text-align: right;" | 34047.2
 +
|-
 +
| Ilmenite
 +
| 98072-94-7
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00233
 +
| style="text-align: right;" | 2461.33
 +
|-
 +
| 2-Propenoic acid, polymer with sodium phosphonate
 +
| 71050-62-9
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.00615
 +
| style="text-align: right;" | 6490
 +
|-
 +
| Diallyldimethylammonium chloride
 +
| 7398-69-8
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00175
 +
| style="text-align: right;" | 1847.6
 +
|-
 +
| Goethite
 +
| 1310-14-1
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00512
 +
| style="text-align: right;" | 5399.79
 +
|-
 +
| Dimethylcocoamine, bis(chloroethyl)<br/> ether, diquaternary ammonium salt
 +
| 68607-28-3
 +
| style="text-align: right;" | 40
 +
| style="text-align: right;" | 0.014
 +
| style="text-align: right;" | 14780.8
 +
|-
 +
| 2,2-Dibromo-3-Nitrilopropionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 20
 +
| style="text-align: right;" | 0.01223
 +
| style="text-align: right;" | 12911.5
 +
|-
 +
| Illite
 +
| 12173-60-3
 +
| style="text-align: right;" | 1
 +
| style="text-align: right;" | 0.0063
 +
| style="text-align: right;" | 6645.59
 +
|-
 +
| Formaldehyde
 +
| 50-00-0
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00015
 +
| style="text-align: right;" | 154.85
 +
|-
 +
| Fatty acids, tall-oil
 +
| 61790-12-3
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.0022
 +
| style="text-align: right;" | 2322.75
 +
|-
 +
| Alkenes, C>10 a-
 +
| 64743-02-8
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.0022
 +
| style="text-align: right;" | 2322.75
 +
|-
 +
| Methanol
 +
| 67-56-1
 +
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 0.00965
 +
| style="text-align: right;" | 10188.3
 +
|-
 +
| Propargyl Alcohol
 +
| 107-19-7
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00073
 +
| style="text-align: right;" | 774.25
 +
|-
 +
| Polyethylene glycol mixture
 +
| 25322-68-3
 +
| style="text-align: right;" | 70
 +
| style="text-align: right;" | 0.01223
 +
| style="text-align: right;" | 12911.5
 +
|-
 +
| Sorbitan monooleate
 +
| 1338-43-8
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00538
 +
| style="text-align: right;" | 5674.54
 +
|-
 +
| Modified thiourea polymer
 +
| 68527-49-1
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.0022
 +
| style="text-align: right;" | 2322.75
 +
|-
 +
| Alcohols, C14-15, ethoxylated
 +
| 68951-67-7
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.0022
 +
| style="text-align: right;" | 2322.75
 +
|-
 +
| Sodium chloride
 +
| 7647-14-5
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00007000
 +
| style="text-align: right;" | 77.43
 +
|-
 +
| Crystalline silica (Quartz)
 +
| 14808-60-7
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 11.5644
 +
| style="text-align: right;" | 12,208,100.0
 +
|-
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 35
 +
| style="text-align: right;" | 0.5134
 +
| style="text-align: right;" | 541976
 +
|-
 +
| Calcite
 +
| 471-34-1
 +
| style="text-align: right;" | 1
 +
| style="text-align: right;" | 0.01948
 +
| style="text-align: right;" | 20569.3
 +
|-
 +
| Isopropanol
 +
| 67-63-0
 +
| style="text-align: right;" | 40
 +
| style="text-align: right;" | 0.014
 +
| style="text-align: right;" | 14780.8
 +
|-
 +
| 2-Propenoic acid, polymer with 2-propenamide, sodium salt
 +
| 25987-30-8
 +
| style="text-align: right;" | 40
 +
| style="text-align: right;" | 0.043
 +
| style="text-align: right;" | 45396.3
 +
|-
 +
| Poly(oxyethylene)nonylphenol ether
 +
| 9016-45-9
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00538
 +
| style="text-align: right;" | 5674.54
 +
|-
 +
| Biotite
 +
| 1302-27-8
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00326
 +
| style="text-align: right;" | 3440.82
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 147: Line 354:
 
!scope="col" | Waste Facility ID
 
!scope="col" | Waste Facility ID
 
|-
 
|-
| 15AUGU
+
| 2013-S01
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,716.02 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 15DECU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,053.83 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 15JULU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,451.92 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 15NOVU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,181.17 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 15OCTU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,444.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 15SEPU
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,473.80 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16APRU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,308.26 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16AUGU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 800.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16DECU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 353.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16FEBU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 890.50 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16JANU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,076.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16JULU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 808.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16JUNU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.50 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-013-20609
 
|-
 
| 16JUNU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 199.44 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-119-28803
 
|-
 
| 16JUNU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 530.06 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16MARU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 973.50 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16MAYU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 11.70 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-119-28780
 
|-
 
| 16MAYU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 44.80 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-119-28803
 
|-
 
| 16MAYU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 896.91 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16NOVU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 36.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-013-20609
 
|-
 
| 16NOVU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 12.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-119-28780
 
|-
 
| 16NOVU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 150.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-119-28803
 
|-
 
| 16NOVU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 365.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16OCTU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 165.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-013-20609
 
|-
 
| 16OCTU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 60.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-119-28780
 
|-
 
| 16OCTU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 290.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-119-28803
 
|-
 
| 16OCTU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 197.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 16SEPU
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 751.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2013-1
 
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 45.31 Tons
 
| style="text-align: right;" | 45.31 Tons
Line 321: Line 360:
 
| 100172
 
| 100172
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 517.28 Tons
 
| style="text-align: right;" | 517.28 Tons
Line 327: Line 366:
 
| PAD059087072
 
| PAD059087072
 
|-
 
|-
| 2013-1
+
| 2013-S01
 
| Drilling Fluid Waste (in Barrels)
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align: right;" | 55.99 Bbl
 
| style="text-align: right;" | 55.99 Bbl
Line 333: Line 372:
 
| 301071
 
| 301071
 
|-
 
|-
| 2014-2
+
| 2014-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 6,934.50 Bbl
 
| style="text-align: right;" | 6,934.50 Bbl
Line 339: Line 378:
 
|  
 
|  
 
|-
 
|-
| 2015-07
+
| 2015-M07
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,451.92 Bbl
 
| style="text-align: right;" | 1,451.92 Bbl
Line 345: Line 384:
 
|  
 
|  
 
|-
 
|-
| 2015-08
+
| 2015-M08
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,716.02 Bbl
 
| style="text-align: right;" | 1,716.02 Bbl
Line 351: Line 390:
 
|  
 
|  
 
|-
 
|-
| 2015-09
+
| 2015-M09
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,473.80 Bbl
 
| style="text-align: right;" | 1,473.80 Bbl
Line 357: Line 396:
 
|  
 
|  
 
|-
 
|-
| 2015-1
+
| 2015-M10
| Fracturing Fluid Waste (in Tons)
 
| style="text-align: right;" | 46.06 Tons
 
| LANDFILL
 
| 100172
 
|-
 
| 2015-1
 
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 5,191.40 Bbl
+
| style="text-align: right;" | 1,444.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2015-10
+
| 2015-M11
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 1,444.00 Bbl
+
| style="text-align: right;" | 1,181.17 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2015-11
+
| 2015-M12
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 1,181.17 Bbl
+
| style="text-align: right;" | 1,053.83 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2015-12
+
| 2015-S01
 +
| Fracturing Fluid Waste (in Tons)
 +
| style="text-align: right;" | 46.06 Tons
 +
| LANDFILL
 +
| 100172
 +
|-
 +
| 2015-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 1,053.83 Bbl
+
| style="text-align: right;" | 5,191.40 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2016-01
+
| 2016-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,076.00 Bbl
 
| style="text-align: right;" | 1,076.00 Bbl
Line 393: Line 432:
 
|  
 
|  
 
|-
 
|-
| 2016-02
+
| 2016-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 890.50 Bbl
 
| style="text-align: right;" | 890.50 Bbl
Line 399: Line 438:
 
|  
 
|  
 
|-
 
|-
| 2016-03
+
| 2016-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 973.50 Bbl
 
| style="text-align: right;" | 973.50 Bbl
Line 405: Line 444:
 
|  
 
|  
 
|-
 
|-
| 2016-04
+
| 2016-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 1,308.26 Bbl
 
| style="text-align: right;" | 1,308.26 Bbl
Line 411: Line 450:
 
|  
 
|  
 
|-
 
|-
| 2016-05
+
| 2016-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 11.70 Bbl
 
| style="text-align: right;" | 11.70 Bbl
Line 417: Line 456:
 
| 34-119-28780
 
| 34-119-28780
 
|-
 
|-
| 2016-05
+
| 2016-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 44.80 Bbl
 
| style="text-align: right;" | 44.80 Bbl
Line 423: Line 462:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2016-05
+
| 2016-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 896.91 Bbl
 
| style="text-align: right;" | 896.91 Bbl
Line 429: Line 468:
 
|  
 
|  
 
|-
 
|-
| 2016-06
+
| 2016-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 100.50 Bbl
 
| style="text-align: right;" | 100.50 Bbl
Line 435: Line 474:
 
| 34-013-20609
 
| 34-013-20609
 
|-
 
|-
| 2016-06
+
| 2016-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 199.44 Bbl
 
| style="text-align: right;" | 199.44 Bbl
Line 441: Line 480:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2016-06
+
| 2016-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 530.06 Bbl
 
| style="text-align: right;" | 530.06 Bbl
Line 447: Line 486:
 
|  
 
|  
 
|-
 
|-
| 2016-07
+
| 2016-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 808.00 Bbl
 
| style="text-align: right;" | 808.00 Bbl
Line 453: Line 492:
 
|  
 
|  
 
|-
 
|-
| 2016-08
+
| 2016-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 800.00 Bbl
 
| style="text-align: right;" | 800.00 Bbl
Line 459: Line 498:
 
|  
 
|  
 
|-
 
|-
| 2016-09
+
| 2016-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 751.00 Bbl
 
| style="text-align: right;" | 751.00 Bbl
Line 465: Line 504:
 
|  
 
|  
 
|-
 
|-
| 2016-10
+
| 2016-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 165.00 Bbl
 
| style="text-align: right;" | 165.00 Bbl
Line 471: Line 510:
 
| 34-013-20609
 
| 34-013-20609
 
|-
 
|-
| 2016-10
+
| 2016-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 60.00 Bbl
 
| style="text-align: right;" | 60.00 Bbl
Line 477: Line 516:
 
| 34-119-28780
 
| 34-119-28780
 
|-
 
|-
| 2016-10
+
| 2016-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 290.00 Bbl
 
| style="text-align: right;" | 290.00 Bbl
Line 483: Line 522:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2016-10
+
| 2016-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 197.00 Bbl
 
| style="text-align: right;" | 197.00 Bbl
Line 489: Line 528:
 
|  
 
|  
 
|-
 
|-
| 2016-11
+
| 2016-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 36.00 Bbl
 
| style="text-align: right;" | 36.00 Bbl
Line 495: Line 534:
 
| 34-013-20609
 
| 34-013-20609
 
|-
 
|-
| 2016-11
+
| 2016-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 12.00 Bbl
 
| style="text-align: right;" | 12.00 Bbl
Line 501: Line 540:
 
| 34-119-28780
 
| 34-119-28780
 
|-
 
|-
| 2016-11
+
| 2016-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 150.00 Bbl
 
| style="text-align: right;" | 150.00 Bbl
Line 507: Line 546:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2016-11
+
| 2016-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 365.00 Bbl
 
| style="text-align: right;" | 365.00 Bbl
Line 513: Line 552:
 
|  
 
|  
 
|-
 
|-
| 2016-12
+
| 2016-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 353.00 Bbl
 
| style="text-align: right;" | 353.00 Bbl
Line 519: Line 558:
 
|  
 
|  
 
|-
 
|-
| 2017-01
+
| 2017-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 359.54 Bbl
 
| style="text-align: right;" | 359.54 Bbl
Line 525: Line 564:
 
|  
 
|  
 
|-
 
|-
| 2017-02
+
| 2017-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 274.91 Bbl
 
| style="text-align: right;" | 274.91 Bbl
Line 531: Line 570:
 
|  
 
|  
 
|-
 
|-
| 2017-05
+
| 2017-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 263.00 Bbl
 
| style="text-align: right;" | 263.00 Bbl
Line 537: Line 576:
 
|  
 
|  
 
|-
 
|-
| 2017-06
+
| 2017-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 296.00 Bbl
 
| style="text-align: right;" | 296.00 Bbl
Line 543: Line 582:
 
|  
 
|  
 
|-
 
|-
| 2017-07
+
| 2017-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 244.00 Bbl
 
| style="text-align: right;" | 244.00 Bbl
Line 549: Line 588:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2017-08
+
| 2017-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 702.00 Bbl
 
| style="text-align: right;" | 702.00 Bbl
Line 555: Line 594:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2017-09
+
| 2017-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 411.00 Bbl
 
| style="text-align: right;" | 411.00 Bbl
Line 561: Line 600:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2017-10
+
| 2017-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 346.00 Bbl
 
| style="text-align: right;" | 346.00 Bbl
Line 567: Line 606:
 
|  
 
|  
 
|-
 
|-
| 2017-11
+
| 2017-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 495.00 Bbl
 
| style="text-align: right;" | 495.00 Bbl
Line 573: Line 612:
 
|  
 
|  
 
|-
 
|-
| 2017-12
+
| 2017-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 472.00 Bbl
 
| style="text-align: right;" | 472.00 Bbl
Line 579: Line 618:
 
|  
 
|  
 
|-
 
|-
| 2018-01
+
| 2018-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 205.00 Bbl
 
| style="text-align: right;" | 205.00 Bbl
Line 585: Line 624:
 
|  
 
|  
 
|-
 
|-
| 2018-02
+
| 2018-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 227.00 Bbl
 
| style="text-align: right;" | 227.00 Bbl
Line 591: Line 630:
 
|  
 
|  
 
|-
 
|-
| 2018-03
+
| 2018-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 239.00 Bbl
 
| style="text-align: right;" | 239.00 Bbl
Line 597: Line 636:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2018-04
+
| 2018-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 191.00 Bbl
 
| style="text-align: right;" | 191.00 Bbl
Line 603: Line 642:
 
|  
 
|  
 
|-
 
|-
| 2018-07
+
| 2018-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 192.00 Bbl
 
| style="text-align: right;" | 192.00 Bbl
Line 609: Line 648:
 
|  
 
|  
 
|-
 
|-
| 2018-08
+
| 2018-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 182.00 Bbl
 
| style="text-align: right;" | 182.00 Bbl
Line 615: Line 654:
 
|  
 
|  
 
|-
 
|-
| 2018-09
+
| 2018-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 146.00 Bbl
 
| style="text-align: right;" | 146.00 Bbl
Line 621: Line 660:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2018-10
+
| 2018-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 45.00 Bbl
 
| style="text-align: right;" | 45.00 Bbl
Line 627: Line 666:
 
| 34-119-28803
 
| 34-119-28803
 
|-
 
|-
| 2018-11
+
| 2018-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 45.00 Bbl
 
| style="text-align: right;" | 45.00 Bbl
Line 633: Line 672:
 
|  
 
|  
 
|-
 
|-
| 2018-12
+
| 2018-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 20.00 Bbl
 
| style="text-align: right;" | 20.00 Bbl
Line 639: Line 678:
 
|  
 
|  
 
|-
 
|-
| 2019-01
+
| 2019-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 9.00 Bbl
 
| style="text-align: right;" | 9.00 Bbl
Line 645: Line 684:
 
|  
 
|  
 
|-
 
|-
| 2019-02
+
| 2019-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 2.00 Bbl
 
| style="text-align: right;" | 2.00 Bbl
Line 651: Line 690:
 
|  
 
|  
 
|-
 
|-
| 2019-03
+
| 2019-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 5.00 Bbl
 
| style="text-align: right;" | 5.00 Bbl
Line 676: Line 715:
 
| 2129815
 
| 2129815
 
| Primary Facility
 
| Primary Facility
| 01/09/2013
+
| 2013-01-09
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 683: Line 722:
 
| 2260179
 
| 2260179
 
| Primary Facility
 
| Primary Facility
| 04/02/2014
+
| 2014-04-02
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 690: Line 729:
 
| 2422785
 
| 2422785
 
| Primary Facility
 
| Primary Facility
| 10/28/2015
+
| 2015-10-28
 
| Site Restoration
 
| Site Restoration
 
| No Violations Noted
 
| No Violations Noted
Line 743: Line 782:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
== Fracking Activities ==
 
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Job Start Date
 
!scope="col" | Job End Date
 
!scope="col" | True Vertical Depth (ft)
 
!scope="col" | Total Water Volume (gal)
 
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
| 1
 
| 10/04/2014
 
| 10/18/2014
 
| style="text-align: right;" | 7312
 
| style="text-align: right;" | 11,093,500.0
 
| style="text-align: right;" | 0
 
|-
 
|}
 
==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Trade Name
 
!scope="col" | Supplier
 
!scope="col" | Purpose
 
!scope="col" | Ingredient Name
 
!scope="col" | CAS Number
 
!scope="col" | Additive Percentage by Mass
 
!scope="col" | Job Percentage by Mass
 
!scope="col" | Mass Used (lb)
 
|-
 
|- valign="top"
 
| rowspan="27"| 1
 
| rowspan="1"| Water
 
| rowspan="1"| Customer & CWS
 
| rowspan="1"| Base Fluid & Mix Water
 
| Water
 
| 7732-18-5
 
| style="text-align: right;" | 100
 
| style="text-align: right;" | 87.7167
 
| style="text-align: right;" | 92,598,900.0
 
|-
 
|- valign="top"
 
| rowspan="26"| Sand (Proppant), DAP-903, DWP-614, BioClear 2000, DWP-NE1, Spearhead Acid
 
| rowspan="26"| CWS
 
| rowspan="26"| Propping Agent, Scale Inhibitor, Viscosifier, Biocide, Non-Emulsifier, Clean Perforations
 
| Apatite
 
| 64476-38-6
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.00326
 
| style="text-align: right;" | 3440.82
 
|-
 
| Distillates (petroleum), hydrotreated middle
 
| 64742-46-7
 
| style="text-align: right;" | 30
 
| style="text-align: right;" | 0.03225
 
| style="text-align: right;" | 34047.2
 
|-
 
| Ilmenite
 
| 98072-94-7
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.00233
 
| style="text-align: right;" | 2461.33
 
|-
 
| 2-Propenoic acid, polymer with sodium phosphonate
 
| 71050-62-9
 
| style="text-align: right;" | 60
 
| style="text-align: right;" | 0.00615
 
| style="text-align: right;" | 6490
 
|-
 
| Diallyldimethylammonium chloride
 
| 7398-69-8
 
| style="text-align: right;" | 5
 
| style="text-align: right;" | 0.00175
 
| style="text-align: right;" | 1847.6
 
|-
 
| Goethite
 
| 1310-14-1
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.00512
 
| style="text-align: right;" | 5399.79
 
|-
 
| Dimethylcocoamine, bis(chloroethyl) ether, diquaternary ammonium salt
 
| 68607-28-3
 
| style="text-align: right;" | 40
 
| style="text-align: right;" | 0.014
 
| style="text-align: right;" | 14780.8
 
|-
 
| 2,2-Dibromo-3-Nitrilopropionamide
 
| 10222-01-2
 
| style="text-align: right;" | 20
 
| style="text-align: right;" | 0.01223
 
| style="text-align: right;" | 12911.5
 
|-
 
| Illite
 
| 12173-60-3
 
| style="text-align: right;" | 1
 
| style="text-align: right;" | 0.0063
 
| style="text-align: right;" | 6645.59
 
|-
 
| Formaldehyde
 
| 50-00-0
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.00015
 
| style="text-align: right;" | 154.85
 
|-
 
| Fatty acids, tall-oil
 
| 61790-12-3
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.0022
 
| style="text-align: right;" | 2322.75
 
|-
 
| Alkenes, C>10 a-
 
| 64743-02-8
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.0022
 
| style="text-align: right;" | 2322.75
 
|-
 
| Methanol
 
| 67-56-1
 
| style="text-align: right;" | 15
 
| style="text-align: right;" | 0.00965
 
| style="text-align: right;" | 10188.3
 
|-
 
| Propargyl Alcohol
 
| 107-19-7
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.00073
 
| style="text-align: right;" | 774.25
 
|-
 
| Polyethylene glycol mixture
 
| 25322-68-3
 
| style="text-align: right;" | 70
 
| style="text-align: right;" | 0.01223
 
| style="text-align: right;" | 12911.5
 
|-
 
| Sorbitan monooleate
 
| 1338-43-8
 
| style="text-align: right;" | 5
 
| style="text-align: right;" | 0.00538
 
| style="text-align: right;" | 5674.54
 
|-
 
| Modified thiourea polymer
 
| 68527-49-1
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.0022
 
| style="text-align: right;" | 2322.75
 
|-
 
| Alcohols, C14-15, ethoxylated
 
| 68951-67-7
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.0022
 
| style="text-align: right;" | 2322.75
 
|-
 
| Sodium chloride
 
| 7647-14-5
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.00007000
 
| style="text-align: right;" | 77.43
 
|-
 
| Crystalline silica (Quartz)
 
| 14808-60-7
 
| style="text-align: right;" | 100
 
| style="text-align: right;" | 11.5644
 
| style="text-align: right;" | 12,208,100.0
 
|-
 
| Hydrochloric acid
 
| 7647-01-0
 
| style="text-align: right;" | 35
 
| style="text-align: right;" | 0.5134
 
| style="text-align: right;" | 541976
 
|-
 
| Calcite
 
| 471-34-1
 
| style="text-align: right;" | 1
 
| style="text-align: right;" | 0.01948
 
| style="text-align: right;" | 20569.3
 
|-
 
| Isopropanol
 
| 67-63-0
 
| style="text-align: right;" | 40
 
| style="text-align: right;" | 0.014
 
| style="text-align: right;" | 14780.8
 
|-
 
| 2-Propenoic acid, polymer with 2-propenamide, sodium salt
 
| 25987-30-8
 
| style="text-align: right;" | 40
 
| style="text-align: right;" | 0.043
 
| style="text-align: right;" | 45396.3
 
|-
 
| Poly(oxyethylene)nonylphenol ether
 
| 9016-45-9
 
| style="text-align: right;" | 5
 
| style="text-align: right;" | 0.00538
 
| style="text-align: right;" | 5674.54
 
|-
 
| Biotite
 
| 1302-27-8
 
| style="text-align: right;" | 0.1
 
| style="text-align: right;" | 0.00326
 
| style="text-align: right;" | 3440.82
 
|-
 
|}
 
For data sources see<ref>{{cite web
 
| title =FracFocus Fracking Chemicals Database
 
| date = 2019-04-02
 
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
| accessdate = 2019-06-19 }}</ref>
 
 
==References==
 
==References==
 
<references/>
 
<references/>

Revision as of 11:04, 3 August 2019

Well Details

Well ID: 37-125-24821
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Morris Township
Operator Name: HG ENERGY II APPALACHIA LLC
Well Pad ID: 148725
Farm/Lease Name: LAMPERSKI NV58KHS
License Status: Active
Spud Date: 2012-12-05
Permit Date: 2012-08-15
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 40.059133
Longitude: -80.311356

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-10-04 2014-10-18 7312 11,093,500.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Customer & CWS Base Fluid & Mix Water Water 7732-18-5 100 87.7167 92,598,900.0
Sand (Proppant), DAP-903, DWP-614,
BioClear 2000, DWP-NE1, Spearhead Acid
CWS Propping Agent, Scale Inhibitor, Viscosifier, Biocide, Non-Emulsifier, Clean Perforations Apatite 64476-38-6 0.1 0.00326 3440.82
Distillates (petroleum), hydrotreated middle 64742-46-7 30 0.03225 34047.2
Ilmenite 98072-94-7 0.1 0.00233 2461.33
2-Propenoic acid, polymer with sodium phosphonate 71050-62-9 60 0.00615 6490
Diallyldimethylammonium chloride 7398-69-8 5 0.00175 1847.6
Goethite 1310-14-1 0.1 0.00512 5399.79
Dimethylcocoamine, bis(chloroethyl)
ether, diquaternary ammonium salt
68607-28-3 40 0.014 14780.8
2,2-Dibromo-3-Nitrilopropionamide 10222-01-2 20 0.01223 12911.5
Illite 12173-60-3 1 0.0063 6645.59
Formaldehyde 50-00-0 0.1 0.00015 154.85
Fatty acids, tall-oil 61790-12-3 0.1 0.0022 2322.75
Alkenes, C>10 a- 64743-02-8 0.1 0.0022 2322.75
Methanol 67-56-1 15 0.00965 10188.3
Propargyl Alcohol 107-19-7 0.1 0.00073 774.25
Polyethylene glycol mixture 25322-68-3 70 0.01223 12911.5
Sorbitan monooleate 1338-43-8 5 0.00538 5674.54
Modified thiourea polymer 68527-49-1 0.1 0.0022 2322.75
Alcohols, C14-15, ethoxylated 68951-67-7 0.1 0.0022 2322.75
Sodium chloride 7647-14-5 0.1 0.00007000 77.43
Crystalline silica (Quartz) 14808-60-7 100 11.5644 12,208,100.0
Hydrochloric acid 7647-01-0 35 0.5134 541976
Calcite 471-34-1 1 0.01948 20569.3
Isopropanol 67-63-0 40 0.014 14780.8
2-Propenoic acid, polymer with 2-propenamide, sodium salt 25987-30-8 40 0.043 45396.3
Poly(oxyethylene)nonylphenol ether 9016-45-9 5 0.00538 5674.54
Biotite 1302-27-8 0.1 0.00326 3440.82

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0
2013 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0
2014 CNX GAS CO LLC 384,903.02 42 0.00 0 0.00 0
2015 CNX GAS CO LLC 1,344,742.26 337 0.00 0 0.00 0
2016 CNX GAS CO LLC 1,346,940.75 366 0.00 0 0.00 0
2017 CNX GAS CO LLC 1,011,479.39 365 0.00 0 0.00 0
2018 HG ENERGY II APPALACHIA LLC 863,389.00 365 0.00 0 0.00 0
2019 HG ENERGY II APPALACHIA LLC 58,666.00 59 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2013-S01 Drill Cuttings (in Tons) 45.31 Tons LANDFILL 100172
2013-S01 Drill Cuttings (in Tons) 517.28 Tons LANDFILL PAD059087072
2013-S01 Drilling Fluid Waste (in Barrels) 55.99 Bbl LANDFILL 301071
2014-S02 Produced Fluid (in Barrels) 6,934.50 Bbl REUSE OTHER THAN ROAD SPREADING
2015-M07 Produced Fluid (in Barrels) 1,451.92 Bbl REUSE OTHER THAN ROAD SPREADING
2015-M08 Produced Fluid (in Barrels) 1,716.02 Bbl REUSE OTHER THAN ROAD SPREADING
2015-M09 Produced Fluid (in Barrels) 1,473.80 Bbl REUSE OTHER THAN ROAD SPREADING
2015-M10 Produced Fluid (in Barrels) 1,444.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-M11 Produced Fluid (in Barrels) 1,181.17 Bbl REUSE OTHER THAN ROAD SPREADING
2015-M12 Produced Fluid (in Barrels) 1,053.83 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S01 Fracturing Fluid Waste (in Tons) 46.06 Tons LANDFILL 100172
2015-S01 Produced Fluid (in Barrels) 5,191.40 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M01 Produced Fluid (in Barrels) RWC 802 1,076.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M02 Produced Fluid (in Barrels) RWC 802 890.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M03 Produced Fluid (in Barrels) RWC 802 973.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M04 Produced Fluid (in Barrels) RWC 802 1,308.26 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M05 Produced Fluid (in Barrels) RWC 802 11.70 Bbl INJECTION DISPOSAL WELL 34-119-28780
2016-M05 Produced Fluid (in Barrels) RWC 802 44.80 Bbl INJECTION DISPOSAL WELL 34-119-28803
2016-M05 Produced Fluid (in Barrels) RWC 802 896.91 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M06 Produced Fluid (in Barrels) RWC 802 100.50 Bbl INJECTION DISPOSAL WELL 34-013-20609
2016-M06 Produced Fluid (in Barrels) RWC 802 199.44 Bbl INJECTION DISPOSAL WELL 34-119-28803
2016-M06 Produced Fluid (in Barrels) RWC 802 530.06 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M07 Produced Fluid (in Barrels) RWC 802 808.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M08 Produced Fluid (in Barrels) RWC 802 800.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M09 Produced Fluid (in Barrels) RWC 802 751.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M10 Produced Fluid (in Barrels) RWC 802 165.00 Bbl INJECTION DISPOSAL WELL 34-013-20609
2016-M10 Produced Fluid (in Barrels) RWC 802 60.00 Bbl INJECTION DISPOSAL WELL 34-119-28780
2016-M10 Produced Fluid (in Barrels) RWC 802 290.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2016-M10 Produced Fluid (in Barrels) RWC 802 197.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M11 Produced Fluid (in Barrels) RWC 802 36.00 Bbl INJECTION DISPOSAL WELL 34-013-20609
2016-M11 Produced Fluid (in Barrels) RWC 802 12.00 Bbl INJECTION DISPOSAL WELL 34-119-28780
2016-M11 Produced Fluid (in Barrels) RWC 802 150.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2016-M11 Produced Fluid (in Barrels) RWC 802 365.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M12 Produced Fluid (in Barrels) RWC 802 353.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017-M01 Produced Fluid (in Barrels) RWC 802 359.54 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-M02 Produced Fluid (in Barrels) RWC 802 274.91 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-M05 Produced Fluid (in Barrels) RWC 802 263.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-M06 Produced Fluid (in Barrels) RWC 802 296.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-M07 Produced Fluid (in Barrels) RWC 802 244.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2017-M08 Produced Fluid (in Barrels) RWC 802 702.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2017-M09 Produced Fluid (in Barrels) RWC 802 411.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2017-M10 Produced Fluid (in Barrels) RWC 802 346.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-M11 Produced Fluid (in Barrels) RWC 802 495.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-M12 Produced Fluid (in Barrels) RWC 802 472.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M01 Produced Fluid (in Barrels) RWC 802 205.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M02 Produced Fluid (in Barrels) RWC 802 227.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M03 Produced Fluid (in Barrels) RWC 802 239.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2018-M04 Produced Fluid (in Barrels) RWC 802 191.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M07 Produced Fluid (in Barrels) RWC 802 192.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M08 Produced Fluid (in Barrels) RWC 802 182.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M09 Produced Fluid (in Barrels) RWC 802 146.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2018-M10 Produced Fluid (in Barrels) RWC 802 45.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2018-M11 Produced Fluid (in Barrels) RWC 802 45.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-M12 Produced Fluid (in Barrels) RWC 802 20.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-M01 Produced Fluid (in Barrels) RWC 802 9.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-M02 Produced Fluid (in Barrels) RWC 802 2.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-M03 Produced Fluid (in Barrels) RWC 802 5.00 Bbl INJECTION DISPOSAL WELL 34-119-28803

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2129815 Primary Facility 2013-01-09 Drilling/Alteration No Violations Noted
2260179 Primary Facility 2014-04-02 Drilling/Alteration No Violations Noted Patterson UTI # 324 drilling for CNX Gas using closed loop system and flare stack. Currently drilling ahead. Current depth @ 8347. Containment under entire rig and support equipment in good condition. BOP tested good at nipple up.
2422785 Primary Facility 2015-10-28 Site Restoration No Violations Noted
2483655 Primary Facility 2016-05-05 Incident- Response to Accident or Event In Compliance with Policy On Thursday May 5, 2016, I received notification of a release of brine water at the NV58HS Well Site located in Morris Township, Washington County. The release was discovered and reported on Wednesday May 4, 2016 and was estimated to involve approximately 30 to 35 gallons of brine water from a leaking dump valve in a GPU. The valve was repaired and the GPU and concrete slab were cleaned. The impacted gravel surrounding the concrete slab was excavated until conductivity probe readings identified unaffected material. The excavated material was placed into drums for off-site disposal. The incident has been determined to be In Compliance with Policy (ICP). No violations are being cited at this time.
2787404 Primary Facility 2018-10-05 Routine/Complete Inspection No Violations Noted On Friday October 5, 2018 I conducted a routine-complete inspection at the NV58 Well Site located in Morris Township, Greene County.

Gas well NV58KHS (125-24821) and the associated infrastructure appeared to be in good condition and functioning properly. The gas well was tagged with identification.

No violations were identified during the inspection.

For data sources see[7]

References