Revision as of 17:43, 12 August 2019

Well Details

Well ID: 34-167-28473
Loading map...
Country: United States
State: Ohio
County: Washington
Municipality: Independence Township
Operator Name: HEINRICH ENTERPRISES INC DBA W
Well Pad ID:
Farm/Lease Name: METZ GLADE
License Status: Producing
License Date: 1987-04-01
Spud Date: 1987-04-01
Spud Drilling Contractor: DEPUY DRILLING
Final Drill Date: 1987-06-06
Well Total Depth: 3995 ft
Configuration: Vertical
Latitude: 39.514216246
Longitude: -81.22039684

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1987-04-01 Issued Date 4/1/87 Expired Date 3/31/88 Acres 0000000 Tool Type CT Proposed Formation OHIO SHALE Proposed Depth 03995 Proposed Drill Depth 03995
Original Spud 1987-04-01
CO 1987-06-06 417 BRADEN DEVELOPMENT CO GeoDate 4/1/87
Completed 1987-06-06
Reached Total Depth 1987-06-06
Completion Report Received 1987-06-16
Construction Permit Expires 1988-03-31
Plugged Back 1988-06-28
CO 1991-04-24 3936 DePUY DRILLING CO GeoDate 4/1/87
Change of Owner 2003-01-27 Operator changed from 3936, DePUY DRILLING CO to 2007, HEINRICH ENTERPRISES INC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 2616 2666 16
1997-06-29 2612 2648 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 WATER FRAC

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 HEINRICH ENTERPRISES INC DBA W 28 0 365
2008 HEINRICH ENTERPRISES INC DBA W 60 0 365
2009 HEINRICH ENTERPRISES INC DBA W 40 0 365
2010 HEINRICH ENTERPRISES INC DBA W 42 0 365
2011 HEINRICH ENTERPRISES INC DBA W 48 0 0
2012 HEINRICH ENTERPRISES INC DBA W 34 0 366
2013 HEINRICH ENTERPRISES INC DBA W 20 0 365
2014 HEINRICH ENTERPRISES INC DBA W 32 0 365
2015 HEINRICH ENTERPRISES INC DBA W 33 0 365
2016 HEINRICH ENTERPRISES INC DBA W 45 0 365
2017 HEINRICH ENTERPRISES INC DBA W 56 0 365
2018 HEINRICH ENTERPRISES INC DBA W 62 0 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 HEINRICH ENTERPRISES INC DBA W Brine 0 365
2008 HEINRICH ENTERPRISES INC DBA W Brine 0 365
2009 HEINRICH ENTERPRISES INC DBA W Brine 0 365
2010 HEINRICH ENTERPRISES INC DBA W Brine 0 365
2011 HEINRICH ENTERPRISES INC DBA W Brine 0
2012 HEINRICH ENTERPRISES INC DBA W Brine 0 366
2013 HEINRICH ENTERPRISES INC DBA W Brine 0 365
2014 HEINRICH ENTERPRISES INC DBA W Brine 0 365
2015 HEINRICH ENTERPRISES INC DBA W Brine 0 365
2016 HEINRICH ENTERPRISES INC DBA W Brine 0 365
2017 HEINRICH ENTERPRISES INC DBA W Brine 0 365
2018 HEINRICH ENTERPRISES INC DBA W Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0947426338 2007-12-03 Production Wells No Violations Inspection this day found casing well with valves open - producing. No IDs, no annual production.
1329326149 2012-02-14 Production Wells No Violations My inspection this day is routine - I found a casing well with the valves open, tied into a sales line and also supplying gas for a small cabin. The well has an identification sticker with all information except permit number - the pumper will have it up today. There is no tank or separator. Annual production records show this well only making 42 mcf/year which is below commercial production limits. Many of Heinrichs wells are below the limits and need TIs filed. Pumper says wells are being metered thru a common meter with other wells.

For data sources see[9]