If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 11: | Line 11: | ||
| County: [[Noble_County,_Ohio|Noble]] | | County: [[Noble_County,_Ohio|Noble]] | ||
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Seneca Township,_Noble_County,_Ohio|Seneca Township]] |
|- | |- | ||
| Operator Name: [[ANTERO RESOURCES CORPORATION]] | | Operator Name: [[ANTERO RESOURCES CORPORATION]] |
Well ID: 34-121-24450 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.881294366,"lon":-81.40443133,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Noble | |
Municipality: Seneca Township | |
Operator Name: ANTERO RESOURCES CORPORATION | |
Well Pad ID: US-OH-000784 | |
Farm/Lease Name: SCHAFER UNIT | |
License Status: Producing | |
License Date: 2013-08-19 | |
Spud Date: 2013-10-18 | |
Spud Drilling Contractor: PATTERSON DRILLING | |
Final Drill Date: 2014-02-02 | |
Well Total Depth: 17076 ft | |
Configuration: Horizontal | |
Latitude: 39.881294366 | |
Longitude: -81.40443133 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2013-08-19 | Proposed Formations:POINT PLEASANT, Issued Date:8/19/2013, Expired Date:8/19/2015 12:00:00 PM, Drilling unit acres:503.091, Proposed Well Type:OG, Proposed Well Class:EDPW |
Reached Total Depth | 2014-02-02 | |
Correction to Well | 2014-02-28 | CORRECTION TO TARGET AND TAKE-POINT INFORMATION (FOOTAGE AND COORDINATES) FROM AS DRILLED SURVEY PLAT. VARIANCE REQUEST GRANTED. |
Correction to Well | 2014-03-27 | UNIT SIZE CHANGED TO 464.032 ACRES. |
Completion Report Received | 2015-05-13 | |
Construction Permit Expires | 2015-08-19 | |
Record Last Modified | 2017-10-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2015-05-13 | 8240 | 16815 | 0 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 03/29/2014 | 04/12/2014 | 7820 | 12,452,700.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Plexslick 953 | Chemplex | Friction Reducer | Polyacrylamide-co-acrylic acid | 9003-06-9 | 32 | 0.01967 | 0 |
Water | 7732-18-5 | 35 | 0.02152 | 0 | ||||
Hydrotreated Petroleum Distillate | 64742-47-8 | 30 | 0.01844 | 0 | ||||
Alcohol Ethoxylate Surfactants | Proprietary | 8 | 0.00492 | 0 | ||||
Plexhib 256 | Chemplex | Corrosion | Methyl Alcohol | 67-56-1 | 70 | 0.00049 | 0 | |
Alcohol Ethoxylate Surfactants | Proprietary | 30 | 0.00021 | 0 | ||||
thiourea-formaldehyde copolymer | 68527-49-1 | 30 | 0.00021 | 0 | ||||
Propargyl Alcohol | 107-19-7 | 8 | 0.00006000 | 0 | ||||
n-olefins | Proprietary | 10 | 0.00007000 | 0 | ||||
20/40 White | US Silica | Propppant | Sand | 14808-60-7 | 100 | 2.9237 | 0 | |
Sodium Persulfate | Chemplex | Breaker | Sodium Persulfate | 7775-27-1 | 100 | 0.00123 | 0 | |
Beta M-4.0 | PfP | Guar Gel | Petroleum Distillate | 64742-47-8 | 55 | 0.04677 | 0 | |
Guar Gum | 9000-30-0 | 50 | 0.04252 | 0 | ||||
Clay | 1302-78-9 | 5 | 0.00425 | 0 | ||||
Surfactant | 154518-36-2 | 1 | 0.00085 | 0 | ||||
Plexaid 673 | Chemplex | Scale Inhibitor | Methyl Alcohol | 67-56-1 | 25 | 0.00393 | 0 | |
Water | 7732-18-5 | 85 | 0.01335 | 0 | ||||
Sodium Salt of Phosphonodimethylated Diamine | Proprietary | 5 | 0.00079 | 0 | ||||
Plexcide 15G | Chemplex | Biocide | Glutaraldehyde | 111-30-8 | 14 | 0.00355 | 0 | |
Ethanol | 64-17-5 | 3 | 0.00076 | 0 | ||||
Water | 7732-18-5 | 90 | 0.02285 | 0 | ||||
Didecyl Dimethyl Ammonium Chloride | 7173-51-5 | 3 | 0.00076 | 0 | ||||
Alkyl Dimethyl Benzyl Ammonium Chloride | 68424-85-1 | 3 | 0.00076 | 0 | ||||
Plexbreak 145 | Chemplex | Non-emulsifier | Diethanolamine | 111-42-2 | 5 | 0.00004000 | 0 | |
Methyl Alcohol | 67-56-1 | 15 | 0.00012 | 0 | ||||
Cocamide Diethanolamine Salt | 68603-42-9 | 10 | 0.00008000 | 0 | ||||
Water | 732-18-5 | 66 | 0.00052 | 0 | ||||
Ethylene Glycol Monobutyl Ether | 111-76-2 | 15 | 0.00012 | 0 | ||||
100 Mesh | US Silica | Propppant | Sand | 14808-60-7 | 100 | 1.2677 | 0 | |
Ferriplex 66 | Chemplex | Iron Control | Acetic Acid | 64-19-7 | 50 | 0.00022 | 0 | |
Citric Acid | 77-92-9 | 30 | 0.00013 | 0 | ||||
Water | 7732-18-5 | 35 | 0.00016 | 0 | ||||
Freshwater | Antero Resources | Water | Water | 7732-18-5 | 100 | 90.709 | 0 | |
Hydrochloric Acid 10-15% | Reagent | Acid | Hydrchloric Acid | 7647-01-0 | 15 | 0.03424 | 0 | |
40/70 White | US Silica | Propppant | Sand | 14808-60-7 | 100 | 4.9144 | 0 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2014-04-12 | H2O | 15 | 4159 Bbl | 216176 | Go Frac LLC | STAGE 49/49 |
2014-03-29 | H2O | 15 | 4174 Bbl | 237410 | Go Frac LLC | STAGE 1/49
STAGES 2-48 SEE IMAGES |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | ANTERO RESOURCES CORPORATION | 1291639 | 66057 | 238 |
2015 | ANTERO RESOURCES CORPORATION | 915524 | 24548 | 365 |
2016 | ANTERO RESOURCES CORPORATION | 522786 | 9124 | 359 |
2017 | ANTERO RESOURCES CORPORATION | 374905 | 4947 | 365 |
2018 | ANTERO RESOURCES CORPORATION | 246077 | 3151 | 361 |
2019 | ANTERO RESOURCES CORPORATION | 52384 | 710 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | ANTERO RESOURCES CORPORATION | Brine | 12281 | 238 |
2015 | ANTERO RESOURCES CORPORATION | Brine | 19970 | 365 |
2016 | ANTERO RESOURCES CORPORATION | Brine | 4730 | 359 |
2017 | ANTERO RESOURCES CORPORATION | Brine | 2300 | 365 |
2018 | ANTERO RESOURCES CORPORATION | Brine | 764 | 361 |
2019 | ANTERO RESOURCES CORPORATION | Brine | 152 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0044889849 | 2014-01-27 | Drill / Deepen / Reopen | No Violations | My inspection today finds the rig is drilling a 8.5 hole at a depth of 16987. The anticipated Total depth is 17000. |
0142632912 | 2014-01-30 | Casing String Witnessed | No Violations | My inspection finds the drilling rig is running 5.5 casing at a depth of 13904. The rig is placing centralizers on predetermined joints. They will be cementing sometime tonight. |
0268733253 | 2016-02-25 | Production Wells | No Violations | My inspection today finds the well is equipped in a manner that is consistent with being capable of production. The tank battery is comprised of eight 400 barrel tanks set inside of a plastic lined steel containment system. There are no personnel onsite at the time of inspection. |
0394164672 | 2017-12-01 | Production Wells | No Violations | |
0489355137 | 2015-07-29 | Production Wells | No Violations | My inspection today finds the well properly equipped to be capable of production. While on location I witnessed one Myers truck arrive and depart. The water sumps and drainage system on the perimeter of the location has been recently cleaned and repaired. |
0496127726 | 2016-07-28 | Production Wells | No Violations | My inspection today finds the well is equipped in a manner consistent with being capable of production. The tank battery consists of eight 400 barrel tanks set in a plastic lined liquid tight steel containment. The tank battery is shared by four other wells on the pad. Two vapor recovery compressors and three incinerators are located near the entry of the well pad. Heavy rain is falling at the time of inspection. |
0533542800 | 2015-09-29 | Production Wells | No Violations | My inspection today finds the well is equipped in a manner that is consistent with being capable of production. The tank battery area of the pad has been enclosed with an earthen berm and a drainage system has been installed. |
0913897933 | 2014-05-14 | Preliminary Restoration | No Violations | My inspection today finds the well appears to be in production. The tank battery consists of eight 400 bbl tanks set in a containment. The site meets preliminary restoration requirements. |
0965679513 | 2014-01-21 | Drill / Deepen / Reopen | No Violations | My inspection today finds the rig is drilling an 8.5 hole at a depth of 10561. |
0992614683 | 2015-06-16 | Production Wells | No Violations | The well is equipped in a manner consistent with being capable of production. All drainage sumps on the location are closed. |
1083644863 | 2016-01-13 | Production Wells | No Violations | My inspection today finds the well is equipped in a manner consistent with being capable of production. The tank battery is comprised of eight 400 barrel tanks set inside of a plastic lined, liquid tight steel containment system. There are three vapor recovery units and three incinerators set at the location. Four other wells are located on the pad and share the production equipment. The ground is covered by three inches of snow at the time of inspection. |
1098089560 | 2017-10-18 | Production Wells | No Violations | The purpose of my inspection was a status check on a production well. The well pad name is Cynthia and it consists of 5 wells. The well was equipped with a production tree style wellhead with a plunger lift system. Production valves were in the open position. Annular pressure monitoring was present. The gauge on the production casing read 310 pounds per square inch and the gauge on the production tubing read 160 pounds per square inch. The production equipment consisted of eight 400 barrel tanks within steel line containment and five gas production units. A vapor recovery system consisted of two compressors, one vent scrubber, and three combustors. The pipeline tie in was located on the North side of the pad. A dust suppressant had been recently applied to the lease road. The identification was located at the wellhead and the production records were current. |
1197765991 | 2018-11-27 | Production Wells | No Violations | On the day of my inspection I witnessed that the well was equipped with 5.5-inch diameter production casing and 2.875-inch diameter tubing equipped with a plunger lift system. At the time of my inspection annular pressure monitoring was in place, and the 13.375-inch diameter casing had 0 pounds per square inch, the 9.625-inch diameter casing had 0 pounds per square inch. Production equipment included a Gas Processing Unit, as well as 8- 400-barrel steel production fluid tanks, and 2 combustors that were shared with the other producing wells on the pad. There was secondary containment around the production fluid tanks, and the Gas Processing Units. There was a midstream valve site on the northwest side of the pad. The well pad was contained within an earthen dike, there were multiple Emergency Shutoff Devices on location. Identification tags were present, and production was up to date. |
1427123561 | 2013-11-01 | Casing String Witnessed | No Violations | My inspection today finds the rig, Falcon 20, ran 407 of 18.635 casing. Allied cemented the casing in place with 176 bbl of class A cement. |
2074019127 | 2017-03-15 | Production Wells | No Violations | The pad name is Cynthia and it consists of 5 wells. The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead with valves in the open position. Annular pressure monitoring was present. The production equipment consisted of five gas production units, eight 400 barrel tanks, two compressors, and three combustors. Identification was present and production records were current. |
2132416106 | 2014-01-31 | Drill / Deepen / Reopen | No Violations | I stopped at the rig to pickup the cement tickets for the 5.5 casing. The rig is preparing to move to another site on the same lease road. |