Well ID: 34-153-21025 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.020622267,"lon":-81.61772217,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Summit | |
Municipality: Barberton City | |
Operator Name: MTM OIL CO | |
Well Pad ID: | |
Farm/Lease Name: B & C MACHINE | |
License Status: Final Restoration | |
License Date: 2005-07-15 | |
Spud Date: 1981-10-30 | |
Spud Drilling Contractor: MOBILE AIR DRLG | |
Final Drill Date: 1981-11-08 | |
Well Total Depth: 3895 ft | |
Configuration: Vertical | |
Latitude: 41.020622267 | |
Longitude: -81.61772217 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1981-10-29 | 494 MTM OIL CO GeoDate 10/29/81 |
Original Spud | 1981-10-30 | PERMIT EXPIRED. |
Completed | 1981-11-08 | PERMIT EXPIRED. |
Reached Total Depth | 1981-11-08 | PERMIT EXPIRED. |
Completion Report Received | 1982-03-30 | PERMIT EXPIRED. |
CO | 1994-06-27 | 494 MTM OIL CO GeoDate 6/27/94 |
Unknown | 1994-06-27 | Issued Date 6/27/94 Expired Date 6/27/95 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date |
CO | 1995-10-18 | 494 MTM OIL CO GeoDate 10/18/95 |
Unknown | 1995-10-18 | Issued Date 10/18/95 Expired Date 10/17/96 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date |
APP | 2005-07-15 | Proposed Formations:CLINTON, Issued Date:7/15/2005, Expired Date:7/15/2006 6:00:00 AM, Drilling unit acres:23.9, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2005-08-15 | PERMIT EXPIRED. |
Construction Permit Expires | 2006-07-15 | PERMIT EXPIRED. |
Record Last Modified | 2017-02-15 | PERMIT EXPIRED. |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2005-07-14 | 3696 | 3750 | 5 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 64000 Gal | 62500 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1997 | MTM OIL CO | 0 | 0 | 0 |
2002 | MTM OIL CO | 0 | 0 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1997 | MTM OIL CO | Brine | 0 | |
2002 | MTM OIL CO | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0002155i90 | 2002-05-28 | Production Wells | No Violations | Met with Dan Cook (330-753-5081) with B & C Machine regarding the current status and future plans for this well. Mr. Cook indicated that the well does occasionally provide natural gas to the facility and is therefore in production. Advised Mr. Cook that the well lacked proper signage and spill containment around the tank battery. Also provided Mr. Cook with a copy of the Plugging Company list for future reference. Will check the site in several weeks to verify that the sign and dike were installed. |
0008779415 | 2002-05-23 | Production Wells | No Violations | Random status check. Operator has never reported production and according to facility employees, the well has not been in production for at least eight years. Well is equipped with one 210 bbl stock tank, one 60 bbl brine tank, one horizontal separator, and a pumping unit. Will call the operator re: any specific plans for the well. |
0937391432 | 2005-08-03 | Production Wells | No Violations | Met on site with Steve Hagen (Intrepid Well Service) to determine annular flow from this well prior to plugging. The well is located on the north side of the PPG Area. Annular flow, at approximately 2 gpm was present. PPG plugging requirements will be necessary. |
1044533484 | 2004-07-20 | Production Wells | Violations Noted | The equipment is deteriorating and leaking. The well must be plugged and abandoned as soon as possible. |
1418511021 | 2003-10-09 | Production Wells | Violations Noted | The well is still under order to plug and abandon or produce. The problem has been the possible influence of the PPG solution mining operation. Inspected the site with Tom Tomastik for his input on how to plug and abandon the well. |
1451730535 | 2005-08-17 | Plug / Plug Back | No Violations | The site has been rough graded with stock tanks still on site. |
1598034840 | 2002-05-23 | Production Wells | Violations Noted | FOLLOW UP TO NOV # 87 Random status check. Operator has never reported production and according to facility employees, the well has not been in production for at least eight years. Well is equipped with one 210 bbl stock tank, one 60 bbl brine tank, one horizontal separator, |
1611384798 | 2003-01-31 | Production Wells | Violations Noted | The requested signage and retention dike have not been installed. The well is located due west of Wolf Creek with a reasonable likelihood of any uncontained spill impacting the creek. The well still provides a small amount of gas to the B&C facility and is therefore not considered idle. Contacted Dan Cook (330-753-5081) with B&C regarding the violations and am waiting for a response. |
2118038441 | 2005-09-15 | Final Restoration | No Violations | Final restoration is approved. |
2140944103 | 2005-08-15 | Production Wells | Violations Noted | The well has been plugged and abandoned and the violation has been corrected. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1044533484 | US-OH-100695 | 2003-02-04 | Failure to legibly identify well | |
1044533484 | US-OH-100696 | 2003-02-04 | No SPCC dike/or failure to keep dike free of water or oil | |
1418511021 | US-OH-112248 | 2003-02-04 | Failure to legibly identify well | |
1418511021 | US-OH-112249 | 2003-02-04 | No SPCC dike/or failure to keep dike free of water or oil | |
1598034840 | US-OH-115647 | 2003-02-04 | Failure to legibly identify well | |
1598034840 | US-OH-115648 | 2003-02-04 | No SPCC dike/or failure to keep dike free of water or oil | |
1611384798 | US-OH-115824 | 2003-02-04 | Failure to legibly identify well | |
1611384798 | US-OH-115825 | 2003-02-04 | No SPCC dike/or failure to keep dike free of water or oil | |
2140944103 | US-OH-121976 | 2003-02-04 | Failure to legibly identify well | |
2140944103 | US-OH-121977 | 2003-02-04 | No SPCC dike/or failure to keep dike free of water or oil |
For data sources see[9]