Revision as of 04:42, 14 August 2019

Well Details

Well ID: 34-153-22528
Loading map...
Country: United States
State: Ohio
County: Summit
Municipality: Green City
Operator Name: DOMINION EAST OHIO
Well Pad ID:
Farm/Lease Name: TURKEYFOOT PROPERTIES
License Status: Storage Well
License Date: 1988-09-28
Spud Date: 1988-10-12
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1988-10-27
Well Total Depth: 4313 ft
Configuration: Vertical
Latitude: 40.979266463
Longitude: -81.52939912

For data sources see[1]

Well History

Well Status Well Status Date Comment
Gas Storage 1988-09-28 Issued Date 9/28/88 Expired Date 9/28/89 Acres 0000000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04313 Proposed Drill Depth 04313
Original Spud 1988-10-12 STORAGE, LOG TYPE=CET, CE
Completed 1988-10-27 STORAGE, LOG TYPE=CET, CE
Reached Total Depth 1988-10-27 STORAGE, LOG TYPE=CET, CE
CO 1989-02-28 240 EAST OHIO GAS CO GeoDate 9/28/88
Completion Report Received 1989-03-24 STORAGE, LOG TYPE=CET, CE
Construction Permit Expires 1989-09-28 STORAGE, LOG TYPE=CET, CE
Record Last Modified 2017-02-15 STORAGE, LOG TYPE=CET, CE

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4078 4172 0
2006-09-11 4110 4111 2
2006-09-11 4140 4167 28

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 500 Gal 0 METHANOL
H2O 0 826 Bbl 57000 FRAC:SAND/WATER/METHANOL/ACID BD
ACID 0 500 Gal 0 FE

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2002 DOMINION EAST OHIO 0 0 0
2003 DOMINION EAST OHIO 0 0 0
2004 DOMINION EAST OHIO 0 0 0
2005 DOMINION EAST OHIO 0 0 0
2006 DOMINION EAST OHIO 0 0 0
2007 DOMINION EAST OHIO 0 0 0
2008 DOMINION EAST OHIO 0 0 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2002 DOMINION EAST OHIO Brine 0 0
2003 DOMINION EAST OHIO Brine 0 0
2004 DOMINION EAST OHIO Brine 0 0
2005 DOMINION EAST OHIO Brine 0 0
2006 DOMINION EAST OHIO Brine 0 0
2007 DOMINION EAST OHIO Brine 0 0
2008 DOMINION EAST OHIO Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0000PL4212 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0963768809 2013-03-19 Storage Well No Violations I inspected dominion East Ohio Gas storage well #3842 today. The wall is located in Section 7, Green Township, Summit County, Ohio. The well is equipped with a master gate valve and a side gate valve with a 3.00 line plumbed into a vertical separator. There is a 2.00 line from the separator plumbed into a domestic meter run. There is a 3.00 line plumbed from the side gate valve into a 100 BBL storage tank. There are two (2) pickup lines on the storage tank and all lids and hatches are secure. There is a dike around the storage tank and the area is sufficient to hold fluids in accordance with 1501-9-9-05. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. No violations found.
1117041567 2018-04-26 Storage Well No Violations I did s status check inspection for this well. The well is equipped with a master valve and a side gate valve. The diked tank battery consists of a steel tank, a horizontal separator and a meter run. There is a domestic gas connection. The well is legibly identified. No compliance issues are cited at this time.
1393030454 2017-09-27 Storage Well No Violations At the time of this inspection, the well site is equipped with:




Domestic line with a meter The lease access is stable and drivable. No violations were observed.

1553123678 2014-11-04 Storage Well No Violations I inspected Dominion East Ohio Gas storage well #3842. The well is equipped with a master gate valve. There was a sales line with a separator. There is a flow gate valve plumbed with a 3.00 line into a 100 BBL storage tank. All lids and hatches on the storage tank are closed and secure. There are two (2) pickup lines on the storage tank and they are secured with valves and bull plugs in place. The tank battery is diked. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. The lease road is stoned and drivable. No violations found.
1576129837 2016-01-05 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve with a 4.5 inch casing into a swage topped with a plug. There is a flow gate valve plumbed with a 3.00 line into a 100 BBL storage tank. All lids and hatches on the storage tank are closed and secure. There are two (2) tank drains on the storage tank and they are secured with valves and bull plugs in place. There is a mechanical separator. The tank battery is diked. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. There is a domestic line with a meter. The lease road is stable and drivable. No violations found.
2018355335 2015-06-16 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve and side gate valve. There is a flow gate valve plumbed with a 3.00 line into a 100 BBL storage tank. All lids and hatches on the storage tank are closed and secure. There are two (2) tank drains on the storage tank and they are secured with valves and bull plugs in place. The tank battery is diked. There is a domestic line with a meter and separator. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. The lease road is stable and drivable. No violations found.

For data sources see[9]