Revision as of 05:29, 14 August 2019

Well Details

Well ID: 34-153-22944
Loading map...
Country: United States
State: Ohio
County: Summit
Municipality: Norton City
Operator Name: SCHREINER OIL & GAS INC
Well Pad ID:
Farm/Lease Name: DEREMER
License Status: Producing
License Date: 2005-05-13
Spud Date: 2005-05-18
Spud Drilling Contractor: G & H DRLG
Final Drill Date: 2005-05-22
Well Total Depth: 3896 ft
Configuration: Vertical
Latitude: 41.042626704
Longitude: -81.61461848

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-05-13 Proposed Formations:CLINTON, Issued Date:5/13/2005, Expired Date:5/13/2006 6:00:00 AM, Drilling unit acres:21.88, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2005-05-18 RBDMS Rec
Completed 2005-05-22 RBDMS Rec
Reached Total Depth 2005-05-22 RBDMS Rec
Completion Report Received 2006-02-02 RBDMS Rec
Construction Permit Expires 2006-05-13 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-04-21 3682 3746 23

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 7 1600 Bbl 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2005 SCHREINER OIL & GAS INC 462 0 94
2006 SCHREINER OIL & GAS INC 6425 79 337
2007 SCHREINER OIL & GAS INC 5624 42 364
2008 SCHREINER OIL & GAS INC 4448 0 362
2009 SCHREINER OIL & GAS INC 3728 71 364
2010 SCHREINER OIL & GAS INC 2866 0 365
2011 SCHREINER OIL & GAS INC 1849 0 364
2012 SCHREINER OIL & GAS INC 2438 0 333
2013 SCHREINER OIL & GAS INC 1906 59 364
2014 SCHREINER OIL & GAS INC 839 59 365
2015 SCHREINER OIL & GAS INC 1384 0 365
2016 SCHREINER OIL & GAS INC 118 0 91
2017 SCHREINER OIL & GAS INC 0 0 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2005 SCHREINER OIL & GAS INC Brine 140 94
2006 SCHREINER OIL & GAS INC Brine 301 337
2007 SCHREINER OIL & GAS INC Brine 112 364
2008 SCHREINER OIL & GAS INC Brine 45 362
2009 SCHREINER OIL & GAS INC Brine 89 364
2010 SCHREINER OIL & GAS INC Brine 0 365
2011 SCHREINER OIL & GAS INC Brine 46 364
2012 SCHREINER OIL & GAS INC Brine 34 333
2013 SCHREINER OIL & GAS INC Brine 157 364
2014 SCHREINER OIL & GAS INC Brine 0 365
2015 SCHREINER OIL & GAS INC Brine 31 365
2016 SCHREINER OIL & GAS INC Brine 0 91
2017 SCHREINER OIL & GAS INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0010814242 2005-05-31 Drill / Deepen / Reopen No Violations The water in the drilling pits has been pumped down and the pits are scheduled to be solidified on 6/01. I told Mike Schreiner that the fence around the pits must stay up until the pits are closed.
0683687566 2005-05-19 Drill / Deepen / Reopen No Violations G> & H. Drilling Set surface.
0878944787 2006-03-13 Production Wells No Violations The well is in production. I contacted Mike Schreiner and told him that he needs to post the required ID, install the fencing around the well and the fencing around tank battery before the wells go into production. He said that he would contact Southway Fence to finish installing the fence and that he would post the required ID.
0963495303 2006-04-25 Production Wells Violations Noted The fence has not been placed around the wellhead and tank battery as required.
1118061940 2005-05-25 Drill / Deepen / Reopen No Violations The drilling pits have been pumped down in anticipation of solidfying the pits next week. No violations at this time.
1144350171 2006-04-04 Production Wells Violations Noted Status check inspection found that the well was in production but the required fencing was not installed and the well identification had not been posted. Additional grading and seeding is also required before the preliminary restoration is approved. Restoration was due by the end of February.
1397910882 2018-07-12 Production Wells No Violations I did an Order follow-up inspection (Chiefs Order 2016-391) and a Compliance notice follow-up inspection for this well. The well is not locked nor legibly identified per the Compliance Notice and Chiefs Order 2016-391 for Failure to Maintain Liability Insurance has not been terminated. The well is equipped with a pumpjack. The well is overgrown with vegetation and shut in. The tank battery consists of a steel production tank, a steel brine tank, a horizontal separator and a meter. The tank battery is overgrown with vegetation and the gate is covered with multiflora rose. The well last produced 118 MCF of gas in 2016.
1540592481 2014-12-09 UrbanProduction Wells Violations Noted I inspected this well on 12/9/2014. The well is located in a residential setting. There is graveled access road to the tank battery and well head. The well is produced utilizing an electrified pump jack. The pump jack was fenced, but not secured with a lock. The required signage on the pump jack fence was missing. Operational conditions surrounding the well head were typical of a pumping operation. The tank battery was fenced and locked. The required signage was missing from the tank battery. The tank battery consists of a 100 barrels oil tank, 25 barrel steel brine tank and a 2408 horizontal mechanical separator. DOM / EOG has a gas measurement meter within the tank battery. Locks and / or plugs were absent from the liquid load lines. There is an unsecured dump line standing in the air, as if a tank had been removed. Last reported production was for the year 2013. The Operator shall : 1.) post the required signage ( Urban rules ), 2.) place locks on all load lines and gates, 3.) remove the unused dump line and any unnecessary equipment lying around. These compliance measures shall be completed and approved by the DOGRM Inspector by 1/15/2015
1650538190 2005-05-18 Drill / Deepen / Reopen No Violations G&H has started drilling. The pit is lined and in good condition. The surface hole will be drilled with fresh water mud.
1711317175 2006-07-12 Preliminary Restoration No Violations Preliminary restoration is approved.
2064294351 2005-05-17 Drill / Deepen / Reopen No Violations On site to witness pit construction. The depth, size and condition was not acceptable and a track hoe was scheduled for Wednesday May 18 to finish the pits. A re-enforced liner was also ordered. I will inspect the pits again on 5/18.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0963495303 US-OH-131032 2006-04-06 General Safety
0963495303 US-OH-131033 2006-04-06 Failure to legibly identify well
1144350171 US-OH-103694 2006-04-06 General Safety
1144350171 US-OH-103695 2006-04-06 Failure to legibly identify well
1540592481 US-OH-114889 2015-01-02 ID (a-i)
1540592481 US-OH-114890 2015-01-02 LOCKS
1540592481 US-OH-114891 2015-01-02 General Safety

For data sources see[9]

References